Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jan 5, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Johnson Controls PowerG, IQPanel and IQHub

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write encrypted traffic or perform a replay attack. The following versions of Johnson Controls PowerG, IQPanel and IQHub are affected: PowerG (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQHub (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 2 (CVE-2025-61738,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read or write encrypted traffic or perform a replay attack. The following versions of Johnson Controls PowerG, IQPanel and IQHub are affected: PowerG (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQHub (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 2 (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 2+ (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) IQPanel 4 (CVE-2025-61738, CVE-2025-61739, CVE-2025-26379, CVE-2025-61740) CVSS Vendor Equipment Vulnerabilities v3 7.6 Johnson Controls Inc. Johnson Controls PowerG, IQPanel and IQHub Cleartext Transmission of Sensitive Information, Reusing a Nonce, Key Pair in Encryption, Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG), Origin Validation Error Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2025-61738 The affected product is vulnerable due to cleartext transmission of sensitive information. This may allow an attacker to capture the network key and read or write encrypted packets on the PowerG network. View CVE Details Affected Products Johnson Controls PowerG, IQPanel and IQHub Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. PowerG: <=53.02, Johnson Controls Inc. IQHub: vers:all/*, Johnson Controls Inc. IQPanel 2: vers:all/*, Johnson Controls Inc. IQPanel 2+: vers:all/*, Johnson Controls Inc. IQPanel 4: <4.6.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following: Vendor fix Update IQPanel 4 to version 4.6.1/4.6.1i. Vendor fix Devices that support PowerG+ should use PowerG v53.05 or later. Mitigation During the installation or enrollment phase of setup, enter the PIN code in the PIN Code field on the sensor enrollment screen. For additional security, Johnson Controls recommends only authorized company personnel or integrators be present during the pairing process. Mitigation Replace all end-of-life products (IQ Panel 2, IQ Panel 2+, IQ Hub) with the latest IQ Panel 4 using firmware version 4.6.1 or greater. Mitigation For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-01 at the Product Security Advisories page. Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N CVE-2025-61739 The affected product is vulnerable due to nonce reuse, which may allow an attacker to perform a replay attack or decrypt captured packets. View CVE Details Affected Products Johnson Controls PowerG, IQPanel and IQHub Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. PowerG: <=53.02, Johnson Controls Inc. IQHub: vers:all/*, Johnson Controls Inc. IQPanel 2: vers:all/*, Johnson Controls Inc. IQPanel 2+: vers:all/*, Johnson Controls Inc. IQPanel 4: <4.6.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following: Vendor fix Update IQPanel 4 to version 4.6.1/4.6.1i. Vendor fix Devices that support PowerG+ should use PowerG v53.05 or later. Mitigation During the installation or enrollment phase of setup, enter the PIN code in the PIN Code field on the sensor enrollment screen. For additional security, Johnson Controls recommends only authorized company personnel or integrators be present during the pairing process. Mitigation Replace all end-of-life products (IQ Panel 2, IQ Panel 2+, IQ Hub) with the latest IQ Panel 4 using firmware version 4.6.1 or greater. Mitigation For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-01 at the Product Security Advisories page. Relevant CWE: CWE-323 Reusing a Nonce, Key Pair in Encryption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L CVE-2025-26379 The affected product is vulnerable due to a weak pseudo-random number generator. This may allow an attacker to read or inject encrypted PowerG packets. View CVE Details Affected Products Johnson Controls PowerG, IQPanel and IQHub Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. PowerG: <=53.02, Johnson Controls Inc. IQHub: vers:all/*, Johnson Controls Inc. IQPanel 2: vers:all/*, Johnson Controls Inc. IQPanel 2+: vers:all/*, Johnson Controls Inc. IQPanel 4: <4.6.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following: Vendor fix Update IQPanel 4 to version 4.6.1/4.6.1i. Vendor fix Devices that support PowerG+ should use PowerG v53.05 or later. Mitigation During the installation or enrollment phase of setup, enter the PIN code in the PIN Code field on the sensor enrollment screen. For additional security, Johnson Controls recommends only authorized company personnel or integrators be present during the pairing process. Mitigation Replace all end-of-life products (IQ Panel 2, IQ Panel 2+, IQ Hub) with the latest IQ Panel 4 using firmware version 4.6.1 or greater. Mitigation For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-01 at the Product Security Advisories page. Relevant CWE: CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L CVE-2025-61740 The affected product is vulnerable to an authentication issue that does not verify the source of a packet. This could allow an attacker to create a denial-of-service condition or modify the configuration of the device. View CVE Details Affected Products Johnson Controls PowerG, IQPanel and IQHub Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. PowerG: <=53.02, Johnson Controls Inc. IQHub: vers:all/*, Johnson Controls Inc. IQPanel 2: vers:all/*, Johnson Controls Inc. IQPanel 2+: vers:all/*, Johnson Controls Inc. IQPanel 4: <4.6.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following: Vendor fix Update IQPanel 4 to version 4.6.1/4.6.1i. Vendor fix Devices that support PowerG+ should use PowerG v53.05 or later. Mitigation During the installation or enrollment phase of setup, enter the PIN code in the PIN Code field on the sensor enrollment screen. For additional security, Johnson Controls recommends only authorized company personnel or integrators be present during the pairing process. Mitigation Replace all end-of-life products (IQ Panel 2, IQ Panel 2+, IQ Hub) with the latest IQ Panel 4 using firmware version 4.6.1 or greater. Mitigation For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-01 at the Product Security Advisories page. Relevant CWE: CWE-346 Origin Validation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L Acknowledgments James Chambers and Sultan Qasim Khan of NCC Group reported these vulnerabilities to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities have been reported to CISA at this time. Revision History Initial Release Date: 2025-12-16 Date Revision Summary 2025-12-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy AFS, AFR and AFF Series

View CSAF Summary Successful exploitation of this vulnerability could compromise the integrity of the product data and disrupt its availability. The following versions of Hitachi Energy AFS, AFR and AFF Series are affected: AFS 660-B/C/S (CVE-2024-3596) AFS 665-B/S (CVE-2024-3596) AFS 670 v2.0 (CVE-2024-3596) AFS 650 (CVE-2024-3596) AFS 655 (CVE-2024-3596) AFS 670 (CVE-2024-3596) AFS 675 (CVE-2024-3596) AFS 677…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could compromise the integrity of the product data and disrupt its availability. The following versions of Hitachi Energy AFS, AFR and AFF Series are affected: AFS 660-B/C/S (CVE-2024-3596) AFS 665-B/S (CVE-2024-3596) AFS 670 v2.0 (CVE-2024-3596) AFS 650 (CVE-2024-3596) AFS 655 (CVE-2024-3596) AFS 670 (CVE-2024-3596) AFS 675 (CVE-2024-3596) AFS 677 (CVE-2024-3596) AFR 677 (CVE-2024-3596) AFF 660 (CVE-2024-3596) AFF 665 (CVE-2024-3596) CVSS Vendor Equipment Vulnerabilities v3 9 Hitachi Energy Hitachi Energy AFS, AFR and AFF Series Improper Enforcement of Message Integrity During Transmission in a Communication Channel Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-3596 The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid response (access-accept, access-reject, or access-challenge) to any other response using a chosen-prefix collision attack against the MD5 response authenticator signature. View CVE Details Affected Products Hitachi Energy AFS, AFR and AFF Series Vendor: Hitachi Energy Product Version: Hitachi Energy AFS 660-B/C/S: vers:all/*, Hitachi Energy AFS 665-B/S: vers:all/*, Hitachi Energy AFS 670 v2.0: vers:all/*, Hitachi Energy AFS 650: vers:all/*, Hitachi Energy AFS 655: vers:all/*, Hitachi Energy AFS 670: vers:all/*, Hitachi Energy AFS 675: vers:all/*, Hitachi Energy AFS 677: vers:all/*, Hitachi Energy AFR 677: vers:all/*, Hitachi Energy AFF 660: vers:all/*, Hitachi Energy AFF 665: vers:all/* Product Status: known_affected Remediations Mitigation Hitachi Energy has identified the following recommended immediate actions: Mitigation All affected products: Set the RADIUS configuration to default which enables the RADIUS server message authenticator option. Vendor fix AFR 677, AFS 650, AFS 655, AFS 670, AFS 675, AFS 677: Command to enable Message Authenticator option: For AFS65x, AFS67x, AFR67x CLI: radius server msgauth MIB: hmAgentRadiusServerMsgAuth Vendor fix AFF 660, AFF 665, AFS 660-B/C/S, AFS 665-B/S, AFS 670: Command to enable Message Authenticator option: For AFS66x, AFS670 v2.0, AFF66x CLI: radius server auth modify msgauth MIB: hm2AgentRadiusServerMsgAuth Mitigation For more information, see the associated Hitachi Energy PSIRT security advisory 8DBD000230 RADIUS vulnerability in Hitachi Energy AFS, AFR and AFF series products. Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Hitachi Energy reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2025-12-16 Date Revision Summary 2025-12-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric GT Designer3

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker obtain plaintext credentials from the project file for GT Designer3, which could result in illegally operating GOT2000 and GOT1000 series devices. The following versions of Mitsubishi Electric GT Designer3 are affected: GT Designer3 Version1 (GOT2000) (CVE-2025-11009) GT Designer3 Version1 (GOT1000) (CVE-2025-11009) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker obtain plaintext credentials from the project file for GT Designer3, which could result in illegally operating GOT2000 and GOT1000 series devices. The following versions of Mitsubishi Electric GT Designer3 are affected: GT Designer3 Version1 (GOT2000) (CVE-2025-11009) GT Designer3 Version1 (GOT1000) (CVE-2025-11009) CVSS Vendor Equipment Vulnerabilities v3 5.1 Mitsubishi Electric Mitsubishi Electric GT Designer3 Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-11009 Information Disclosure vulnerability due to Cleartext Storage of Sensitive Information(CWE-312) exists in GT Designer3. GT Designer3 stores credentials and verifies them in plain text, therefore an attacker may be able to obtain plaintext credentials from the project file for GT Designer3. As a result, the attacker may be able to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials. View CVE Details Affected Products Mitsubishi Electric GT Designer3 Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric GT Designer3 Version1 (GOT2000): vers:all/*, Mitsubishi Electric GT Designer3 Version1 (GOT1000): vers:all/* Product Status: known_affected Remediations Mitigation Mitsubishi Electric recommends that users take the following mitigation measures to minimize the risk of exploiting this vulnerability: Mitigation Use a personal computer with the affected product within the LAN and block remote login from untrusted networks, hosts, and users. Mitigation When connecting a personal computer with the affected product to the Internet, use a firewall, virtual private network (VPN), etc., to prevent unauthorized access and allow only trusted users to remote login. Mitigation Install an antivirus software on the computer using the affected product. Mitigation Don't open untrusted files or click untrusted links. Mitigation For more information, see Mitsubishi Electric's security advisory. Relevant CWE: CWE-312 Cleartext Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Hea-Eun Moon and Junbeom Gwak of Red Alert Lab at NSHC reported this vulnerability to Mitsubishi Electric Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2025-12-16 Date Revision Summary 2025-12-16 1 Initial Republication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Releases Six Industrial Control Systems Advisories

CISA released six Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-350-01 Güralp Systems FMUS (Fortimus) Series and MIN (Minimus) Series ICSA-25-350-02 Johnson Controls PowerG, IQPanel and IQHub ICSA-25-350-03 Hitachi Energy AFS, AFR and AFF Series ICSA-25-350-04 Mitsubishi Electric GT…
Read full source summary
CISA released six Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-350-01 Güralp Systems FMUS (Fortimus) Series and MIN (Minimus) Series ICSA-25-350-02 Johnson Controls PowerG, IQPanel and IQHub ICSA-25-350-03 Hitachi Energy AFS, AFR and AFF Series ICSA-25-350-04 Mitsubishi Electric GT Designer3 ICSA-25-224-02 Johnson Controls iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 (Update A) ICSA-25-308-01 Fuji Electric Monitouch V-SFT-6 (Update A) CISA encourages users and administrators to review newly released ICS Advisories for technical details and mitigations.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14611 Gladinet CentreStack and Triofox Hard Coded Cryptographic Vulnerability CVE-2025-43529 Apple Multiple Products Use-After-Free WebKit Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14611 Gladinet CentreStack and Triofox Hard Coded Cryptographic Vulnerability CVE-2025-43529 Apple Multiple Products Use-After-Free WebKit Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14174 Google Chromium Out-of-Bounds Memory Access Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14174 Google Chromium Out-of-Bounds Memory Access Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2018-4063 Sierra Wireless AirLink ALEOS Unrestricted Upload of File with Dangerous Type Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01:…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2018-4063 Sierra Wireless AirLink ALEOS Unrestricted Upload of File with Dangerous Type Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Siemens Building X - Security Manager Edge Controller

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.9 ATTENTION: Low attack complexity Vendor: Siemens Equipment:…
Read full source summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.9 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Building X - Security Manager Edge Controller (ACC-AP) Vulnerability: Improper Verification of Cryptographic Signature 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to upload maliciously modified firmware onto the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Building X - Security Manager Edge Controller (ACC-AP): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347 Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of valid firmware from the server to the device could modify the firmware "on the fly". CVE-2022-31807 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). A CVSS v4 score has also been calculated for CVE-2022-31807. A base score of 5.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Siemens ProductCERT reported this vulnerability to CISA. 4. MITIGATIONS Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk: Building X - Security Manager Edge Controller (ACC-AP): Use the ACC Firmware App to apply updates in a controlled and authenticated manner, ensuring that only verified firmware packages from the official SIOS portal are installed on the controller. Validate the integrity of the downloaded firmware by confirming its hash value. Access to the controller should remain limited to authorized personnel, and credentials must be protected and updated according to policy to reduce the risk of unauthorized modifications or the installation of tampered firmware Building X - Security Manager Edge Controller (ACC-AP): Currently no fix is planned As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals. Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage For more information see the associated Siemens security advisory SSA-420375 in HTML and CSAF. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. 5. UPDATE HISTORY December 11, 2025: Initial Republication of Siemens Product CERT SSA-420375
· CISA Cybersecurity Advisory

Cybersecurity Performance Goals 2.0 for Critical Infrastructure

Today, CISA released updated Cross-Sector Cybersecurity Performance Goals (CPG 2.0) with measurable actions for critical infrastructure owners and operators to achieve a foundational level of cybersecurity. This update incorporates lessons learned, aligns with the most recent National Institute of Standards and Technology Cybersecurity Framework revisions, and addresses the most common and impactful threats facing…
Read full source summary
Today, CISA released updated Cross-Sector Cybersecurity Performance Goals (CPG 2.0) with measurable actions for critical infrastructure owners and operators to achieve a foundational level of cybersecurity. This update incorporates lessons learned, aligns with the most recent National Institute of Standards and Technology Cybersecurity Framework revisions, and addresses the most common and impactful threats facing critical infrastructure today. CPG 2.0 includes a new component focused on the essential role of governance in managing cybersecurity. It emphasizes accountability, risk management, and strategic integration of cybersecurity into day-to-day operations, reinforcing the principle that effective governance is the cornerstone of a resilient cyber posture. CPGs are streamlined and outcome-driven cybersecurity protections for information technology and operational technology environments and provide: Clear, foundational practices aligned with real-world threats. Straightforward, outcome-oriented language to aid implementation. A baseline for guiding investment, benchmarking progress, and reducing risk in measurable ways. For more information, visit CPG 2.0 and Cross-Sector Cybersecurity Performance Goals | CISA.
· CISA Cybersecurity Advisory

2025 CWE Top 25 Most Dangerous Software Weaknesses

The Cybersecurity and Infrastructure Security Agency (CISA), in collaboration with the Homeland Security Systems Engineering and Development Institute (HSSEDI), operated by the MITRE Corporation, has released the 2025 Common Weakness Enumeration (CWE) Top 25 Most Dangerous Software Weaknesses. This annual list identifies the most critical weaknesses adversaries exploit to compromise systems, steal data, or disrupt…
Read full source summary
The Cybersecurity and Infrastructure Security Agency (CISA), in collaboration with the Homeland Security Systems Engineering and Development Institute (HSSEDI), operated by the MITRE Corporation, has released the 2025 Common Weakness Enumeration (CWE) Top 25 Most Dangerous Software Weaknesses. This annual list identifies the most critical weaknesses adversaries exploit to compromise systems, steal data, or disrupt services. Prioritizing the weaknesses outlined in the Top 25 is integral to CISA’s Secure by Design and Secure by Demand initiatives, which promote building and procuring secure technology solutions. CISA and MITRE encourage organizations to review this list and use it to inform their respective software security strategies. The 2025 CWE Top 25: Supports Vulnerability Reduction: By focusing on the Top 25, organizations can prioritize lifecycle changes, adopt safer architectural decisions, and reduce high-impact vulnerabilities related to injection, access control, and memory safety defects. Drives Cost Efficiencies: Eliminating weaknesses early reduces downstream remediation; addressing them before deployment is more efficient and cost effective than patching, reconfiguring, or responding to emergency incidents. Strengthens Customer and Stakeholder Trust: Transparent efforts to identify, mitigate, and monitor weaknesses demonstrate commitment to Secure by Design principles. Organizations that prioritize eliminating recurring weaknesses contribute to a safer software ecosystem. Promotes Consumer Awareness: The Top 25 empowers consumers to understand underlying causes of common vulnerabilities, supports more informed purchasing decisions, and encourages adoption of products that follow robust security engineering practices. Recommendations for Stakeholders: For Developers and Product Teams: Review the 2025 CWE Top 25 to identify high-priority weaknesses and adopt Secure by Design practices in development. For Security Teams: Incorporate the Top 25 into vulnerability management and application security testing to assess and mitigate critical weaknesses. For Procurement and Risk Managers: Use the Top 25 as a benchmark when evaluating vendors and apply Secure by Demand guidelines to ensure investment in secure products. By shining a light on the most dangerous software weaknesses, CISA and MITRE reinforce collective efforts to reduce vulnerabilities at the source, strengthen national cybersecurity, and improve long-term resilience. For details, refer to the 2025 CWE Top 25.
Browse saved snapshots