[
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/26/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Five Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/26/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added five new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-14634\" target=\"_blank\" data-entity-type=\"external\">CVE-2018-14634</a> Linux Kernel Integer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-52691\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-52691</a> SmarterTools SmarterMail Unrestricted Upload of File with Dangerous Type Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-21509\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-21509</a> Microsoft Office Security Feature Bypass Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-23760\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-23760</a> SmarterTools SmarterMail Authentication Bypass Using an Alternate Path or Channel Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24061\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-24061</a> GNU InetUtils Argument Injection Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 26 Jan 26 12:00:00 +0000",
        "last_updated": "Mon, 26 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/23/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/23/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>Known Exploited Vulnerabilities (KEV) Catalog</u></a>, based on evidence of active exploitation.&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW240314876 BCX8\">\n<ul>\n<li><a class=\"Hyperlink SCXW240314876 BCX8\" href=\"https://www.cve.org/CVERecord?id=CVE-2024-37079\" target=\"_blank\" rel=\"noreferrer noopener\"><u>CVE-2024-37079</u></a> Broadcom VMware vCenter Server Out-of-bounds Write Vulnerability&nbsp;</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\"><u>Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</u></a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\"><u>BOD 22-01 Fact Sheet</u></a> for more information.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Fri, 23 Jan 26 12:00:00 +0000",
        "last_updated": "Fri, 23 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards",
        "title": "Product Categories for Technologies That Use Post-Quantum Cryptography Standards",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards",
        "summary": "<h2><strong>Executive Summary</strong></h2>\n<p>In response to the June 6, 2025, Executive Order (EO) 14306, \u201cSustaining Select Efforts to Strengthen the Nation\u2019s Cybersecurity and Amending Executive Order 13694 and Executive Order 14144,\u201d the Cybersecurity and Infrastructure Security Agency (CISA) is providing and regularly updating the below lists to aid in post-quantum cryptography (PQC) adoption. The lists include hardware and software categories with example types of widely available products that use PQC standards to protect sensitive information.<a href=\"#Note1\"><sup>1</sup></a> The lists focus on categories of available products, typically acquired by the federal government, that utilize cryptographic algorithms. Because PQC-capable products are widely available in the listed categories, organizations should acquire only PQC-capable products when planning acquisitions and procuring products in these categories. &nbsp;</p>\n<h2><strong>Introduction</strong></h2>\n<h3>Purpose</h3>\n<p>The lists below are CISA\u2019s response to Executive Order (EO) 14306, which instructed:</p>\n<p>By December 1, 2025, the Secretary of Homeland Security, acting through the Director of the Cybersecurity and Infrastructure Security Agency (CISA), and in consultation with the Director of the National Security Agency, shall release and thereafter regularly update a list of product categories in which products that support post-quantum cryptography (PQC) are widely available.</p>\n<p>When a particular category offers widely available PQC-capable products, organizations should plan acquisitions to procure only PQC-capable products from that category.</p>\n<h3>Scope and Definitions</h3>\n<p>The scope of the lists below includes categories of hardware and software products that are\u2014or are anticipated to be\u2014widely available and use PQC standards.&nbsp;</p>\n<p><strong>Note:</strong> \u201cWidely available\u201d describes products that are generally available in the marketplace, and agencies can acquire them in accordance with their typical procurement policies and procedures.</p>\n<p>The categories cover hardware and software products that apply PQC standards for encryption and authentication through the following cryptographic functions:</p>\n<ul>\n<li><strong>Key establishment:</strong><a href=\"#Note2\"><strong><sup>2</sup></strong></a> A function in the lifecycle of keying material; the process by which cryptographic keys are securely established among cryptographic modules using manual transport methods (e.g., key loaders), automated methods (e.g., key-transport and/or key-agreement protocols), or a combination of automated and manual methods (consisting of key transport plus key agreement).</li>\n<li><strong>Digital signatures:</strong><a href=\"#Note3\"><strong><sup>3</sup></strong></a><sup> </sup>The result of a cryptographic transformation of data that, when properly implemented, provides the services of 1. origin authentication, 2. data integrity, and 3. signer non-repudiation.&nbsp;</li>\n</ul>\n<p>Key establishment is often essential for establishing confidential communication using encryption among two or more parties. Digital signatures are often essential for authenticating the parties participating in a communication and for establishing the authenticity of data, products, and services.</p>\n<p>Automated cryptographic discovery and inventory products are out of scope of these lists.</p>\n<h2><strong>Considerations for Products That Use PQC Standards</strong></h2>\n<h3><strong>PQC Transition of Information Technology (IT) Infrastructure</strong></h3>\n<p>Recognizing the global need to support PQC algorithms, product manufacturers are developing new products and updating existing products to incorporate post-quantum cryptographic standards.&nbsp;</p>\n<h3>National Institute of Standards and Technology</h3>\n<p>In 2016, the National Institute of Standards and Technology (NIST) initiated a process to solicit, evaluate, and standardize one or more quantum-resistant public-key cryptographic algorithms. The ongoing PQC standardization process has produced PQC standards and will likely standardize additional algorithms in the coming years.</p>\n<p>The NIST Internal Report (IR) 8547, <em>Transition to Post-Quantum Cryptography Standards</em>, describes NIST\u2019s expected approach to transitioning from quantum-vulnerable cryptographic algorithms to post-quantum digital signature algorithms and key-establishment schemes. The report identifies existing quantum-vulnerable cryptographic standards and the current quantum-resistant standards that organizations will use in the transition. The report informs the efforts and timelines of federal agencies, industry, and standards organizations for transitioning products, services, and infrastructure to PQC. NIST will revise this report and feed into other algorithms- and application-specific guidance for the transition to PQC as necessary to support transition timelines.</p>\n<p><a href=\"#Table1\">Table 1</a> shows three NIST PQC standards along with a recommendation for stateful hash-based signature algorithms that support quantum-resistant standards.<br>&nbsp;<a class=\"ck-anchor\" id=\"Table1\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 1: NIST Standard PQC Algorithms</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\">Cryptographic Function</p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\">Algorithm Standard</p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Standard</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Key Establishment</td>\n<td>Module-Lattice-Based Key- Encapsulation Mechanism (ML-KEM)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/203/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 203</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Module-Lattice-Based Digital Signature Algorithm (ML-DSA)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/204/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 204</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Stateless Hash-Based Digital Signature Algorithm (SLH-DSA)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/205/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 205</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Stateful Hash-Based Digital Signature Algorithms: Leighton-Micali Signature Scheme (LMS), Hierarchical Merkle Signature Scheme (HMS), eXtended Merkle Signature Scheme (XMSS), eXtended Merkle Signature Scheme with Multi-Tree (XMSSMT)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/sp/800/208/final\" target=\"_blank\">NISTSP 800-208</a></td>\n</tr>\n</tbody>\n</table>\n<h2><strong>Product Lists</strong></h2>\n<p><a href=\"#Table2\">Table 2</a> details widely available categories with respective types of hardware and software products that use PQC standards to protect sensitive information well into the foreseeable future, including after the advent of a cryptographically relevant quantum computer (CRQC). Organizations building PQC migration plans can use these categories as a guide to assess future technological needs. Once a category is listed as having PQC-capable products widely available, organizations should plan acquisitions to procure only PQC-capable products in that category.<a href=\"#Note4\"><sup>4</sup></a>&nbsp;</p>\n<p><a href=\"#Table3\">Table 3</a> does not list categories of PQC-capable products that are currently widely available; instead, it lists product categories where manufacturer implementation and testing of PQC capabilities are encouraged. It is important that&nbsp;the products listed in <a href=\"#Table3\">Table 3</a> implement PQC for core features and for all secondary functionality, such as for software updates.&nbsp;As the <a href=\"#Table3\">Table 3</a> product categories mature their capabilities and transition to PQC, CISA will move them from <a href=\"#Table3\">Table 3</a> to the list in <a href=\"#Table2\">Table 2</a>.</p>\n<p><a href=\"#Table2\">Tables 2</a> and <a href=\"#Table3\">3</a> consider efforts within the General Services Administration (GSA),<a href=\"#Note5\"><sup>5</sup></a><sup>,</sup><a href=\"#Note6\"><sup>6</sup></a> CISA,<a href=\"#Note7\"><sup>7</sup></a> NIST,<a href=\"#Note8\"><sup>8</sup></a> and the National Security Agency (NSA)<a href=\"#Note9\"><sup>9</sup></a>. &nbsp;<strong>Note: </strong><a href=\"#Table2\">Tables 2</a> and <a href=\"#Table3\">3</a> are not exhaustive lists; CISA will periodically update these tables as needed to cover new examples of widely available products that use PQC standards.</p>\n<p><a class=\"ck-anchor\" id=\"Table2\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 2: Widely Available Hardware and Software Product Categories That Use PQC Standards</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\"><strong>Product Category*</strong></p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Example Product Type</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Cloud Services</td>\n<td>Platform-as-a-service (PaaS), infrastructure-as-a-service (IaaS)&nbsp;</td>\n</tr>\n<tr>\n<td>Collaboration Software</td>\n<td>Chat/messaging</td>\n</tr>\n<tr>\n<td>Web Software</td>\n<td>Web browsers, web servers</td>\n</tr>\n<tr>\n<td>Endpoint Security<a href=\"#Note10\"><sup>10</sup></a></td>\n<td>Data at rest (DAR) security, full disk encryption</td>\n</tr>\n</tbody>\n</table>\n<p><strong>*&nbsp;</strong>Most of these categories have implemented&nbsp;PQC for key encapsulation and key agreement but have not yet widely implemented PQC for digital signatures and authentication. As a result, these categories are not considered to be <em>fully</em> quantum resistant; CISA includes them on this list because one of their main security services is quantum resistant and Federal Civilian Executive Branch (FCEB) departments and agencies should procure them appropriately.&nbsp;</p>\n<p><a class=\"ck-anchor\" id=\"Table3\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 3: Hardware and Software Product Categories Transitioning to Use PQC Standards</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\"><strong>Product Category</strong></p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Example Product Type</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Networking Hardware</td>\n<td>Proxy servers, routers, firewalls, switches, appliances</td>\n</tr>\n<tr>\n<td>Networking Software</td>\n<td>Software-defined network (SDN), domain name service (DNS), network operating systems</td>\n</tr>\n<tr>\n<td>Cloud Services</td>\n<td>Software-as-a-service (SaaS)</td>\n</tr>\n<tr>\n<td>Telecommunications Hardware</td>\n<td>Desk phones, fax machine, voice over IP (VoIP), radio</td>\n</tr>\n<tr>\n<td>Computers (Physical and Virtual)</td>\n<td>Operating systems, hypervisors, containers</td>\n</tr>\n<tr>\n<td>Computer Peripherals</td>\n<td>Wireless keyboards, wireless headsets</td>\n</tr>\n<tr>\n<td>Storage Area Network</td>\n<td>Appliances, operating systems, applications</td>\n</tr>\n<tr>\n<td>Identity, Credential, and Access Management (ICAM) Software</td>\n<td>Identity management systems, identity provider and federation services, certificate authorities, access brokers, access management software, public key infrastructure (PKI) management software&nbsp;</td>\n</tr>\n<tr>\n<td>Identity, Credential, and Access Management (ICAM) Hardware</td>\n<td>Hardware security modules (HSM), authentication tokens, badges/cards, badge/card readers</td>\n</tr>\n<tr>\n<td>Collaboration Software</td>\n<td>Email clients, email servers, conferencing, file sharing</td>\n</tr>\n<tr>\n<td>Data</td>\n<td>Database, Structured Query Language (SQL) server&nbsp;</td>\n</tr>\n<tr>\n<td>Endpoint Security</td>\n<td>Password managers, antivirus/anti-malware software, asset management</td>\n</tr>\n<tr>\n<td>Enterprise Security</td>\n<td>Continuous diagnostics and mitigation (CDM) tools, intrusion detection/monitoring, inspection systems, security information, and event monitoring (SIEM)</td>\n</tr>\n</tbody>\n</table>\n<p><strong>Note:&nbsp;</strong>The above lists<strong>&nbsp;</strong>exclude categories of hardware and software products, such as operational technology (OT) and internet of things (IoT) devices, that are not considered traditional IT products. These also should be transitioning to PQC standards as well but are out of scope for these lists.</p>\n<h2><strong>Notes&nbsp;</strong></h2>\n<ol>\n<li><a class=\"ck-anchor\" id=\"Note1\"></a>Per EO 14306, \u201cthe Secretary of Homeland Security, acting through the Director of the Cybersecurity and Infrastructure Security Agency (CISA), and in consultation with the Director of the National Security Agency, shall release and thereafter regularly update a list of product categories in which products that support post-quantum cryptography (PQC) are widely available.\u201d</li>\n<li><a class=\"ck-anchor\" id=\"Note2\"></a><a href=\"https://csrc.nist.rip/glossary/term/key_establishment\" target=\"_blank\">https://csrc.nist.rip/glossary/term/key_establishment</a></li>\n<li><a class=\"ck-anchor\" id=\"Note3\"></a><a href=\"https://csrc.nist.rip/glossary/term/digital_signature\" target=\"_blank\">https://csrc.nist.rip/glossary/term/digital_signature</a></li>\n<li><a class=\"ck-anchor\" id=\"Note4\"></a>Even once a product that supports PQC standards is procured, it may need to use non-PQC algorithms for a time for interoperability reasons.</li>\n<li><a class=\"ck-anchor\" id=\"Note5\"></a><a href=\"https://buy.gsa.gov/api/system/files/documents/final-508c-pqc_buyer-s_guide_2025.pdf\" target=\"_blank\">https://buy.gsa.gov/api/system/files/documents/final-508c-pqc_buyer-s_guide_2025.pdf</a></li>\n<li><a class=\"ck-anchor\" id=\"Note6\"></a><a href=\"https://www.gsa.gov/technology/it-contract-vehicles-and-purchasing-programs/multiple-award-schedule-it\" target=\"_blank\">https://www.gsa.gov/technology/it-contract-vehicles-and-purchasing-programs/multiple-award-schedule-it</a></li>\n<li><a class=\"ck-anchor\" id=\"Note7\"></a><a href=\"https://www.cisa.gov/sites/default/files/cdm_files/HWAMInitializationGuide.pdf\">https://www.cisa.gov/sites/default/files/cdm_files/HWAMInitializationGuide.pdf</a></li>\n<li><a class=\"ck-anchor\" id=\"Note8\"></a><a href=\"https://www.nist.gov/itl/executive-order-improving-nations-cybersecurity/critical-software-definition-explanatory\" target=\"_blank\">https://www.nist.gov/itl/executive-order-improving-nations-cybersecurity/critical-software-definition-explanatory</a></li>\n<li><a class=\"ck-anchor\" id=\"Note9\"></a><a href=\"https://www.niap-ccevs.org/products\" target=\"_blank\">https://www.niap-ccevs.org/products</a></li>\n<li><a class=\"ck-anchor\" id=\"Note10\"></a>The principal security service of the Endpoint Security category is not naturally quantum vulnerable. When procuring, one needs to ensure that other relevant features of the product, such as firmware updates, are utilizing post-quantum cryptography (PQC).</li>\n</ol>\n<p>&nbsp;</p>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.&nbsp;</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards\" data-entity-type=\"external\">CISA Product Survey</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Fri, 23 Jan 26 12:00:00 +0000",
        "last_updated": "Fri, 23 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-01",
        "title": "Schneider Electric EcoStruxure Process Expert",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure\u2122 Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure\u2122 Process Expert for AVEVA System Platform product enables users to achieve operational profitability from design engineering to meeting the demands of modern-day production. It provides an asset centric and object-oriented automation platform to deploy system-wide standards in a digital ecosystem. Failure to apply the Fix/Mitigations provided below may risk modification of the executable binaries, which could result in privilege escalation.</strong></p>\n<p>The following versions of Schneider Electric are affected:</p>\n<ul>\n<li>EcoStruxure\u2122 Process Expert (CVE-2025-13905)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Process Expert</td>\n<td>Incorrect Default Permissions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13905</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-276 : Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-13905\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure\u2122 Process Expert versions prior to 2025, EcoStruxure\u2122 Process Expert All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 2025 of EcoStruxure\u2122 Process Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert</p>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for all the future versions of EcoStruxure\u2122\u2122 Process Expert for AVEVA System Platform that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Recommended to apply application whitelisting at system level to allow execution of authenticated applications. More details available here: https://www.se.com/ww/en/download/document/EIO0000004778/ \u2022 Recommended to allow access to the system only to the required users.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n<li>Charit Misra of DNV Cyber reported this vulnerability to Schneider Electric</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-013-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-01-22</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-013-02 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-08",
        "title": "EVMAPA",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could lead to degraded service, a denial-of-service, or unauthorized remote command execution, which could lead to spoofing or a manipulation of charging station statuses.</strong></p>\n<p>The following versions of EVMAPA are affected:</p>\n<ul>\n<li>EVMAPA (CVE-2025-54816, CVE-2025-53968, CVE-2025-55705)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>EVMAPA</td>\n<td>EVMAPA</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Czechia, Slovakia</li>\n<li><strong>Company Headquarters Location: </strong>Czechia</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-54816</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability occurs when a WebSocket endpoint does not enforce proper authentication mechanisms, allowing unauthorized users to establish connections. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-54816\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-54816: EVMAPA informed CISA some of their charging stations do not allow changes to the authorization key using the Open Charge Point Protocol (OCPP). Currently, charge point operators have the option to connect stations using WebSocket Secure (WSS), and EVMAPA connects stations they supply via their own VPN. For OCPP 2.x and newer stations, EVMAPA plans to implement BASIC authorization control.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-53968</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability arises because there are no limitations on the number of authentication attempts a user can make. An attacker can exploit this weakness by continuously sending authentication requests, leading to a denial-of-service (DoS) condition. This can overwhelm the authentication system, rendering it unavailable to legitimate users and potentially causing service disruption. This can also allow attackers to conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-53968\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-53968: EVMAPA did not release a statement regarding this vulnerability. Contact EVMAPA directly for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-55705</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability occurs when the system permits multiple simultaneous connections to the backend using the same charging station ID. This can result in unauthorized access, data inconsistency, or potential manipulation of charging sessions. The lack of proper session management and expiration control allows attackers to exploit this weakness by reusing valid charging station IDs to establish multiple sessions concurrently.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-55705\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-55705: EVMAPA informed CISA they have resolved this issue and do not allow simultaneous connection of charging stations with the same CBID.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine reported these vulnerabilities to CISA</li>\n<li>Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-03",
        "title": "Rockwell Automation CompactLogix 5370",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.</strong></p>\n<p>The following versions of Rockwell Automation CompactLogix 5370 are affected:</p>\n<ul>\n<li>CompactLogix 5370 (CVE-2025-11743)</li>\n<li>CompactLogix 5370 (CVE-2025-11743)</li>\n<li>CompactLogix 5370 (CVE-2025-11743)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation CompactLogix 5370</td>\n<td>Improper Validation of Specified Quantity in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11743</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is vulnerable to a denial-of-service issue. The security issue occurs when a malformed CIP forward open message is sent. This could result in a major nonrecoverable fault, which would require a restart to recover.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-11743\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation CompactLogix 5370</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation CompactLogix 5370: &lt;=34.013, Rockwell Automation CompactLogix 5370: &lt;=35.012, Rockwell Automation CompactLogix 5370: 36.011</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation reports that the following versions are fixed:</p>\n<p><strong>Mitigation</strong><br>Versions 37.011 and later</p>\n<p><strong>Mitigation</strong><br>Version 34.016</p>\n<p><strong>Mitigation</strong><br>Version 35.015</p>\n<p><strong>Mitigation</strong><br>Version 36.012</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices.</p>\n<p><strong>Mitigation</strong><br>For additional details, refer to advisory SD1770 on the Rockwell Automation security page.</p>\n<p><strong>Mitigation</strong><br>For additional details, refer to advisory SD1770 on the Rockwell Automation security page.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1284.html\">CWE-1284 Improper Validation of Specified Quantity in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation SD1770</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/22/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Four Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/22/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added four new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-31125\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-31125</a> Vite Vitejs Improper Access Control Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34026\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-34026</a> Versa Concerto Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-54313\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-54313</a> Prettier eslint-config-prettier Embedded Malicious Code Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-68645\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-68645</a> Synacor Zimbra Collaboration Suite (ZCS) PHP Remote File Inclusion Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-07",
        "title": "Delta Electronics DIAView",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could enable an attacker to execute arbitrary code.</strong></p>\n<p>The following versions of Delta Electronics DIAView are affected:</p>\n<ul>\n<li>DIAView (CVE-2026-0975)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Delta Electronics</td>\n<td>Delta Electronics DIAView</td>\n<td>Improper Neutralization of Special Elements used in a Command ('Command Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0975</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>DIAView functions can execute shell commands within a project script. If an attacker tricks the victim into running a project containing a malicious script, then arbitrary code can be executed when the malicious project starts.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-0975\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics DIAView</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics DIAView: 4.2.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Delta Electronics recommends users update to DIAView v4.4 or later.</p>\n<p><strong>Mitigation</strong><br>For more information, see Delta Electronics advisory Delta-PCSA-2026-00002.</p>\n<p><strong>Mitigation</strong><br>Delta Electronics offers users the following general recommendations:</p>\n<p><strong>Mitigation</strong><br>Do not click on untrusted Internet links or open unsolicited attachments in emails.</p>\n<p><strong>Mitigation</strong><br>Avoid exposing control systems and equipment to the Internet.</p>\n<p><strong>Mitigation</strong><br>Place control system networks and remote devices behind firewalls, and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use a secure access method, such as a virtual private network (VPN).</p>\n<p><strong>Mitigation</strong><br>If you have any product-related support concerns, contact Delta via the portal page for any information or materials you may require.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/77.html\">CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous researcher at Trend Zero Day Initiative reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-04",
        "title": "Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a failure within the operating system of the machine hosting the ICU tool.</strong></p>\n<p>The following versions of Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool are affected:</p>\n<ul>\n<li>iSTAR Configuration Utility (ICU) tool (CVE-2025-26386)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.1</td>\n<td>Johnson Controls Inc.</td>\n<td>Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool</td>\n<td>Stack-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Government Services and Facilities, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Ireland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-26386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Under certain circumstances, a successful exploitation of this vulnerability could result in failure within the operating system of the machine hosting the ICU tool.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-26386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Johnson Controls Inc.</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool: &lt;=6.9.7</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Johnson Controls Inc. recommends the following:</p>\n<p><strong>Vendor fix</strong><br>Update the iSTAR Configuration Utility (ICU) tool to version 6.9.8</p>\n<p><strong>Mitigation</strong><br>For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2025-08 v1 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Tenable reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05",
        "title": "Weintek cMT X Series HMI EasyWeb Service",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow a low-level user to alter privileges and gain full control to the device.</strong></p>\n<p>The following versions of Weintek cMT X Series HMI EasyWeb Service are affected:</p>\n<ul>\n<li>cMT3072XH (CVE-2025-14750, CVE-2025-14751)</li>\n<li>cMT3072XH(T) (CVE-2025-14750, CVE-2025-14751)</li>\n<li>cMT-SVRX-820 (CVE-2025-14750, CVE-2025-14751)</li>\n<li>cMT-CTRL01 (CVE-2025-14750, CVE-2025-14751)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>Weintek</td>\n<td>Weintek cMT X Series HMI EasyWeb Service</td>\n<td>External Control of Assumed-Immutable Web Parameter, Unverified Password Change</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14750</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14750\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Weintek cMT X Series HMI EasyWeb Service</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Weintek</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Weintek cMT3072XH: &gt;=20200630|&lt;20241112, Weintek cMT3072XH(T): &gt;=20200630|&lt;20241112, Weintek cMT-SVRX-820: &gt;=20220413|&lt;20240919, Weintek cMT-CTRL01: &gt;=20230308|&lt;20250827</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Weintek recommends users implement the following mitigation techniques:</p>\n<p><strong>Vendor fix</strong><br>cMT3072XH: Version 20241112</p>\n<p><strong>Vendor fix</strong><br>cMT3072XH(T): Version 20241112</p>\n<p><strong>Vendor fix</strong><br>cMT-SVRX-820: Version 20240919</p>\n<p><strong>Vendor fix</strong><br>cMT-CTRL01: Version 20250827</p>\n<p><strong>Mitigation</strong><br>For more information, see Weintek's planned notice: https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/472.html\">CWE-472 External Control of Assumed-Immutable Web Parameter</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14751</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A low-privileged user can bypass account credentials without confirming the user's current authentication state, which may lead to unauthorized privilege escalation.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14751\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Weintek cMT X Series HMI EasyWeb Service</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Weintek</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Weintek cMT3072XH: &gt;=20200630|&lt;20241112, Weintek cMT3072XH(T): &gt;=20200630|&lt;20241112, Weintek cMT-SVRX-820: &gt;=20220413|&lt;20240919, Weintek cMT-CTRL01: &gt;=20230308|&lt;20250827</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Weintek recommends users implement the following mitigation techniques:</p>\n<p><strong>Vendor fix</strong><br>cMT3072XH: Version 20241112</p>\n<p><strong>Vendor fix</strong><br>cMT3072XH(T): Version 20241112</p>\n<p><strong>Vendor fix</strong><br>cMT-SVRX-820: Version 20240919</p>\n<p><strong>Vendor fix</strong><br>cMT-CTRL01: Version 20250827</p>\n<p><strong>Mitigation</strong><br>For more information, see Weintek's planned notice: https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/620.html\">CWE-620 Unverified Password Change</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-02",
        "title": "AutomationDirect CLICK Programmable Logic Controller",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to impersonate users, escalate privileges, gain unauthorized access to systems and services, and decrypt sensitive data.</strong></p>\n<p>The following versions of AutomationDirect CLICK Programmable Logic Controller are affected:</p>\n<ul>\n<li>CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051)</li>\n<li>CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051)</li>\n<li>CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>AutomationDirect</td>\n<td>AutomationDirect CLICK Programmable Logic Controller</td>\n<td>Weak Encoding for Password, Plaintext Storage of a Password</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-67652</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker with access to the project file could use the exposed credentials to impersonate users, escalate privileges, or gain unauthorized access to systems and services. The absence of robust encryption or secure handling mechanisms increases the likelihood of this type of exploitation, leaving sensitive information more vulnerable.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-67652\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AutomationDirect CLICK Programmable Logic Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AutomationDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AutomationDirect CLICK Programmable Logic Controller: C0-0x, AutomationDirect CLICK Programmable Logic Controller: C0-1x, AutomationDirect CLICK Programmable Logic Controller: C2-x</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AutomationDirect recommends that users update CLICK PLUS and firmware to V3.90.</p>\n<p><strong>Mitigation</strong><br>If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:</p>\n<p><strong>Mitigation</strong><br>Network Isolation \u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.</p>\n<p><strong>Mitigation</strong><br>Secure Communications \u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.</p>\n<p><strong>Mitigation</strong><br>Access Control \u2013 Restrict both physical and logical access to authorized personnel only.</p>\n<p><strong>Mitigation</strong><br>Application Whitelisting \u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.</p>\n<p><strong>Mitigation</strong><br>Endpoint Protection \u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.</p>\n<p><strong>Mitigation</strong><br>Logging &amp; Monitoring \u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.</p>\n<p><strong>Mitigation</strong><br>Backup &amp; Recovery \u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.</p>\n<p><strong>Mitigation</strong><br>Ongoing Risk Assessment \u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/261.html\">CWE-261 Weak Encoding for Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-25051</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-25051\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AutomationDirect CLICK Programmable Logic Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AutomationDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AutomationDirect CLICK Programmable Logic Controller: C0-0x, AutomationDirect CLICK Programmable Logic Controller: C0-1x, AutomationDirect CLICK Programmable Logic Controller: C2-x</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AutomationDirect recommends that users update CLICK PLUS and firmware to V3.90.</p>\n<p><strong>Mitigation</strong><br>If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:</p>\n<p><strong>Mitigation</strong><br>Network Isolation \u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.</p>\n<p><strong>Mitigation</strong><br>Secure Communications \u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.</p>\n<p><strong>Mitigation</strong><br>Access Control \u2013 Restrict both physical and logical access to authorized personnel only.</p>\n<p><strong>Mitigation</strong><br>Application Whitelisting \u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.</p>\n<p><strong>Mitigation</strong><br>Endpoint Protection \u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.</p>\n<p><strong>Mitigation</strong><br>Logging &amp; Monitoring \u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.</p>\n<p><strong>Mitigation</strong><br>Backup &amp; Recovery \u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.</p>\n<p><strong>Mitigation</strong><br>Ongoing Risk Assessment \u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/256.html\">CWE-256 Plaintext Storage of a Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Dylan Chambers Bourgeois of Triskele Labs reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-06",
        "title": "Hubitat Elevation Hubs",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an authenticated attacker to escalate their privileges and control devices outside of their authorized scope.</strong></p>\n<p>The following versions of Hubitat Elevation Hubs are affected:</p>\n<ul>\n<li>Elevation C3 (CVE-2026-1201)</li>\n<li>Elevation C4 (CVE-2026-1201)</li>\n<li>Elevation C5 (CVE-2026-1201)</li>\n<li>Elevation C7 (CVE-2026-1201)</li>\n<li>Elevation C8 (CVE-2026-1201)</li>\n<li>Elevation C8 pro (CVE-2026-1201)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Hubitat</td>\n<td>Hubitat Elevation Hubs</td>\n<td>Authorization Bypass Through User-Controlled Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1201</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Authorization Bypass Through User-Controlled Key vulnerability in Hubitat Elevation home automation controllers prior to version 2.4.2.157 could allow a remote authenticated user to control connected devices outside of their authorized scope via client-side request manipulation.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-1201\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hubitat Elevation Hubs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hubitat</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Hubitat Elevation C3: &lt;firmware_2.4.2.157, Hubitat Elevation C4: &lt;firmware_2.4.2.157, Hubitat Elevation C5: &lt;firmware_2.4.2.157, Hubitat Elevation C7: &lt;firmware_2.4.2.157, Hubitat Elevation C8: &lt;firmware_2.4.2.157, Hubitat Elevation C8 pro: &lt;firmware_2.4.2.157</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Hubitat has released the following for users to implement:</p>\n<p><strong>Mitigation</strong><br>Firmware version 2.4.2.157</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Aaron 'theHastyOne' Hasty of Ostrich Lab reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/21/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/21/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20045\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-20045</a> Cisco Unified Communications Products Code Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 21 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 21 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-01",
        "title": "Schneider Electric EcoStruxure Foxboro DCS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-020-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability disclosed by INTEL used in the EcoStruxure\u2122 Foxboro DCS product formerly known as Foxboro Evo Process Automation System and I/A Series. The [EcoStruxure\u2122 Foxboro DCS product](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/#overview) is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediations provided below may risk allowing an authenticated user to potentially enable information disclosure via a side channel with local access, which could result in loss of system functionality or unauthorized access to system functions.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected:</p>\n<ul>\n<li>EcoStruxure\u2122 Foxboro DCS Virtualization Server ()</li>\n<li>EcoStruxure\u2122 Foxboro DCS Virtualization Server ()</li>\n<li>EcoStruxure\u2122 Foxboro DCS Standard Workstation ()</li>\n<li>EcoStruxure\u2122 Foxboro DCS Standard Workstation ()</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Foxboro DCS</td>\n<td>Exposure of Sensitive Information to an Unauthorized Actor</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-12130</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability disclosed by INTEL in Intel Xeon Silver 4110 and Intel Xeon W-2123 and prior impact Schneider Electric EcoStruxure\u2122 Foxboro DCS V91 DCS Virtualization Server and H92 DCS Standard Workstation.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-12130\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Foxboro DCS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>&nbsp;</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Upgrade to the latest Foxboro server (V95) and workstations (Dell D96): Please contact your local Service Representative or Schneider Electric Process Automation Global Customer Support Center for information on how to migrate to new hardware. https://pasupport.schneider-electric.com/home2020.asp?code=i1swrtYD1O7YcWYkLo5iZJHxEEY9U-agDBBtcLSP7EXks</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The BIOS, OS security patches are applied to significantly reduce the exploit possibility. Additional information is available here: https://se.my.site.com/PAkb/s/article/KA000127385 Several layers of defense-in-depth mechanisms available in the recommended security architecture of DCS system, including the computers themselves, and by following the General Security Recommendations specified below mitigate this vulnerability. https://pasupport.schneider-electric.com/Content/Documents/IASeries/b0700_lastrev/b0700hz_f.pdf</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/200.html\">CWE-200 Exposure of Sensitive Information to an Unauthorized Actor</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N\">CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-343-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-12-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-12-09</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-01-20</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2025-343-01 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 20 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 20 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-03",
        "title": "Rockwell Automation Verve Asset Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-020-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities may allow an attacker to access sensitive information stored in variables within the ADI server.</strong></p>\n<p>The following versions of Rockwell Automation Verve Asset Manager are affected:</p>\n<ul>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n<li>Verve Asset Manager (CVE-2025-14376, CVE-2025-14377)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.9</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation Verve Asset Manager</td>\n<td>Insecure Storage of Sensitive Information, Cleartext Storage of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14376</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue was discovered within the legacy ADI server component of Verve Asset Manager, where unencrypted sensitive data was stored in environment variables. This component was retired and became optional beginning with the 1.36 release in 2024.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14376\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Verve Asset Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Verve Asset Manager: 1.33, Rockwell Automation Verve Asset Manager: 1.34, Rockwell Automation Verve Asset Manager: 1.35, Rockwell Automation Verve Asset Manager: 1.36, Rockwell Automation Verve Asset Manager: 1.37, Rockwell Automation Verve Asset Manager: 1.38, Rockwell Automation Verve Asset Manager: 1.39, Rockwell Automation Verve Asset Manager: 1.40, Rockwell Automation Verve Asset Manager: 1.41, Rockwell Automation Verve Asset Manager: 1.41.1, Rockwell Automation Verve Asset Manager: 1.41.2, Rockwell Automation Verve Asset Manager: 1.41.3</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation reports that the issue was resolved in version 1.42, and the component has been optional since version 1.36. Rockwell Automation recommends updating to the latest available version.</p>\n<p><strong>Mitigation</strong><br>For additional details, refer to the advisory on the Rockwell Automation security page.</p>\n<p><strong>Mitigation</strong><br>For further assistance, contact Rockwell Automation TechConnect for help.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/922.html\">CWE-922 Insecure Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14377</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager. The issue occurred because unencrypted sensitive information was incorrectly stored during playbook execution. This component was retired and became optional starting with the 1.36 release in 2024.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14377\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Verve Asset Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Verve Asset Manager: 1.33, Rockwell Automation Verve Asset Manager: 1.34, Rockwell Automation Verve Asset Manager: 1.35, Rockwell Automation Verve Asset Manager: 1.36, Rockwell Automation Verve Asset Manager: 1.37, Rockwell Automation Verve Asset Manager: 1.38, Rockwell Automation Verve Asset Manager: 1.39, Rockwell Automation Verve Asset Manager: 1.40, Rockwell Automation Verve Asset Manager: 1.41, Rockwell Automation Verve Asset Manager: 1.41.1, Rockwell Automation Verve Asset Manager: 1.41.2, Rockwell Automation Verve Asset Manager: 1.41.3</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation reports that the issue was resolved in version 1.42, and the component has been optional since version 1.36. Rockwell Automation recommends updating to the latest available version.</p>\n<p><strong>Mitigation</strong><br>For additional details, refer to the advisory on the Rockwell Automation security page.</p>\n<p><strong>Mitigation</strong><br>For further assistance, contact Rockwell Automation TechConnect for help.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.9</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-20</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-20</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation's security advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 20 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 20 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-02",
        "title": "Schneider Electric devices using CODESYS Runtime",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-020-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-020-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of multiple vulnerabilities disclosed on CODESYS runtime system V3 communication server. Many vendors, including Schneider Electric, embed CODESYS in their offers. If successfully exploited, these vulnerabilities could result in a denial of service or, in some cases, in remote code execution on PacDrive controllers, Modicon Controllers M241 / M251 / M262 / M258 / LMC058 / LMC078 / M218 , HMISCU, the Simulation Runtime SoftSPS from EcoStruxure Machine Expert and EcoStruxure Microgrid Operation products. Failure to apply the mitigations provided below may result in denial of service and/or arbitrary remote code execution.</strong></p>\n<p>The following versions of Schneider Electric devices using CODESYS Runtime are affected:</p>\n<ul>\n<li>HMISCU Controller (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller LMC078 (CVE-2022-4046, CVE-2023-28355)</li>\n<li>Modicon Controller M241 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller M251 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller M262 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller M258 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller LMC058 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Modicon Controller M218 (CVE-2022-4046, CVE-2023-28355)</li>\n<li>PacDrive 3 Controllers: LMC Eco/Pro/Pro2 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>SoftSPS embedded in EcoStruxure Machine Expert (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Vijeo Designer embedded in EcoStruxure Machine Expert (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>HMISCU Controller ()</li>\n<li>Modicon Controller M241 ()</li>\n<li>Modicon Controller M251 ()</li>\n<li>Modicon Controller M262 ()</li>\n<li>PacDrive 3 Controllers: LMC Eco/Pro/Pro2 ()</li>\n<li>SoftSPS embedded in EcoStruxure Machine Expert ()</li>\n<li>Vijeo Designer embedded in EcoStruxure Machine Expert ()</li>\n<li>Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series iPC series with Vijeo Designer runtime ()</li>\n<li>Vijeo Designer Basic ()</li>\n<li>Harmony iPC series ()</li>\n<li>Magelis XBT series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Easy Modicon M310 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670)</li>\n<li>Harmony P6 series ()</li>\n<li>Vijeo Designer runtime ()</li>\n<li>Vijeo Designer runtime ()</li>\n<li>Easy Modicon M310 ()</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric devices using CODESYS Runtime</td>\n<td>Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Validation of Integrity Check Value, Improper Validation of Consistency within Input, Out-of-bounds Write, Stack-based Buffer Overflow, Untrusted Pointer Dereference, Improper Input Validation, Files or Directories Accessible to External Parties, Uncontrolled Search Path Element, Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Improper Restriction of Excessive Authentication Attempts, Exposure of Resource to Wrong Sphere</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4046</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In addition to the functionality described above, there are memory access functions that allow the PLC application code to read or write memory. These are not limited to the data memories that are assigned to it or allocated by it. For this reason, the PLC application code can potentially access the entire RAM memory of the CODESYS Control runtime process surrounding it. This could allow PLC programmers who have successfully authenticated themselves at the controller to execute PLC application code that can modify itself or read or write sensitive data of the CODESYS Control runtime process.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-4046\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller LMC078 All Versions, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric Modicon Controller M218 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u00b4s Modicon LMC078 controllers have reached end of their life and are no longer commercially available. They have been replaced by the Modicon M262 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Modicon M218 controllers have reached their end of life and are no longer commercially available. They have been replaced by the Modicon Easy M200 and Modicon M241 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-28355</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The PLC application code executed by the CODESYS Control Runtime contains a checksum. This enables the CODESYS development system to check at login whether its loaded project matches the PLC application code executed on the controller. This checksum is not sufficient to reliably detect PLC application code that has been modified in memory or boot application files that have been manipulated.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-28355\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller LMC078 All Versions, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric Modicon Controller M218 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u00b4s Modicon LMC078 controllers have reached end of their life and are no longer commercially available. They have been replaced by the Modicon M262 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Modicon M218 controllers have reached their end of life and are no longer commercially available. They have been replaced by the Modicon Easy M200 and Modicon M241 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/354.html\">CWE-354 Improper Validation of Integrity Check Value</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47378</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests with inconsistent content can cause the CmpFiletransfer component to read internally from an invalid address, potentially leading to a denial-of-service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47378\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1288.html\">CWE-1288 Improper Validation of Consistency within Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47379</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to memory, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47379\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47380</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47380\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47381</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47381\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47382</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47382\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47383</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47383\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47384</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47384\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47387</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47387\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47388</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47388\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47389</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47389\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47390</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47390\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpAppForce component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47392</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests with inconsistent content can cause the CmpApp/CmpAppBP/CmpAppForce components to read internally from an invalid address, potentially leading to a denial-of-service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47392\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1288.html\">CWE-1288 Improper Validation of Consistency within Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47393</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication, specific crafted communication requests can cause the CmpFiletransfer component to dereference addresses provided by the request for internal read access, which can lead to a denial-of-service situation.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47393\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/822.html\">CWE-822 Untrusted Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47391</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Crafted communication requests can cause the affected products to read internally from an invalid address, potentially leading to a denial-of-service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-47391\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1288.html\">CWE-1288 Improper Validation of Consistency within Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37545</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37545\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37546</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37546\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37547</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37547\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37548</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37548\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37549</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37549\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37550</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37550\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37551</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specially crafted communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37551\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37552</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37552\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37553</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37553\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37554</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37554\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37555</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37555\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37556</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37556\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37557</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37557\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37558</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37558\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37559</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of service condition.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-37559\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3662</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The CODESYS Development System is vulnerable to the execution of malicious binaries from the current working directory.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-3662\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/427.html\">CWE-427 Uncontrolled Search Path Element</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Notification Center of the CODESYS Development System receives messages without ensuring that the message was not modified during transmission. This finally enables MITMs code execution when the user clicks the Learn More button.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-3663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/924.html\">CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3669</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Notification Center of the CODESYS Development System receives messages without ensuring that the message was not modified during transmission. This finally enables MITMs code execution when the user clicks the Learn More button.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-3669\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.3</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3670</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Scripting executes potentially malicious scripts saved by another user.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-3670\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric devices using CODESYS Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot.</p>\n<p><strong>No fix planned</strong><br>Schneider Electric\u2019s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information.</p>\n<p><strong>Vendor fix</strong><br>PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application.</p>\n<p><strong>Mitigation</strong><br>\u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. \u2022 Use encrypted communication links. \u2022 The \u201cCybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\u201d provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242. \u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105.</p>\n<p><strong>Mitigation</strong><br>\u2022 Enable the optional \u2018Implicit Checks\u2019 on logic applications. \u2022 Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. \u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp</p>\n<p><strong>Vendor fix</strong><br>Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer.</p>\n<p><strong>Vendor fix</strong><br>Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic.</p>\n<p><strong>Vendor fix</strong><br>Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer.</p>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploitation: \u2022 Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.\u2022 Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required. \u2022 Limit the access to both development and control system by physical means, operating system features, etc. \u2022 Protect both development and control system by using up to date malware protection.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/668.html\">CWE-668 Exposure of Resource to Wrong Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider\u2019s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all.</p>\n<hr>\n<h2>Details</h2>\n<p>Vulnerabilities disclosed by CODESYSTM group in the CODESYS Runtime and Simulation Runtime impact Schneider Electric controller products and software. Additional information about the vulnerabilities can be found in the CODESYSTM Advisories at: Advisory 2023-02 \u2022 Advisory 2023-03 \u2022 Advisory 2023-04 \u2022 Advisory 2023-05 \u2022 Advisory 2023-06 \u2022 Advisory 2023-07 \u2022 Advisory 2023-08 \u2022 Advisory 2023-09</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2023-192-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2023-07-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2023-07-11</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2023-08-08</td>\n<td>2</td>\n<td>New CODESYS advisories 2023-04 to 2023-09 added. Additional impacted product: Harmony and Easy Harmony, Vijeo Designer embedded in EcoStruxure Machine Expert.</td>\n</tr>\n<tr>\n<td>2024-01-09</td>\n<td>3</td>\n<td>Remediations added for different products.</td>\n</tr>\n<tr>\n<td>2024-03-12</td>\n<td>4</td>\n<td>A remediation is now available for HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series</td>\n</tr>\n<tr>\n<td>2024-04-09</td>\n<td>5</td>\n<td>A remediation is now available for Easy Harmony HMIET6/HMIFT6, and Magelis HMIGXU series</td>\n</tr>\n<tr>\n<td>2024-06-11</td>\n<td>6</td>\n<td>Easy Modicon M310 is added to the list of products impacted</td>\n</tr>\n<tr>\n<td>2025-08-12</td>\n<td>7</td>\n<td>Remediations are available for Harmony iPC series and Harmony P6 series with Vijeo Designer.</td>\n</tr>\n<tr>\n<td>2025-11-11</td>\n<td>8</td>\n<td>Remediation is available for Easy Modicon M310.</td>\n</tr>\n<tr>\n<td>2025-12-09</td>\n<td>9</td>\n<td>Replaced advisory IDs with CVE IDs. Added vulnerability details, including CVE descriptions, CWE identifiers, CVSS scores, and vector strings. Corrected mappings of affected and fixed products for each CVE.</td>\n</tr>\n<tr>\n<td>2026-01-20</td>\n<td>10</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2023-192-04 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 20 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 20 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-01",
        "title": "AVEVA Process Optimization",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable an attacker to execute remote code, perform SQL injection, escalate privileges, or access sensitive information.</strong></p>\n<p>The following versions of AVEVA Process Optimization are affected:</p>\n<ul>\n<li>Process Optimization (CVE-2025-61937, CVE-2025-64691, CVE-2025-61943, CVE-2025-65118, CVE-2025-64729, CVE-2025-65117, CVE-2025-64769)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>AVEVA</td>\n<td>AVEVA Process Optimization</td>\n<td>Improper Control of Generation of Code ('Code Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Uncontrolled Search Path Element, Missing Authorization, Use of Potentially Dangerous Function, Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United Kingdom</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-61937</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an unauthenticated miscreant to achieve remote code execution under OS System privileges of \"taoimr\" service, potentially resulting in complete compromise of the Model Application Server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-61937\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-64691</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to tamper with TCL Macro scripts and escalate privileges to OS System, potentially resulting in complete compromise of the Model Application Server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-64691\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-61943</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Standard User) to tamper with queries in Captive Historian and achieve code execution under SQL Server administrative privileges, potentially resulting in complete compromise of the SQL Server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-61943\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-65118</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to trick Process Optimization services into loading arbitrary code and escalate privileges to OS System, potentially resulting in complete compromise of the Model Application Server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-65118\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/427.html\">CWE-427 Uncontrolled Search Path Element</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-64729</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to tamper with Process Optimization project files, embed code, and escalate their privileges to the identity of a victim user who subsequently interacts with the project files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-64729\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-65117</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Designer User) to embed OLE objects into graphics, and escalate their privileges to the identity of a victim user who subsequently interacts with the graphical elements.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-65117\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/676.html\">CWE-676 Use of Potentially Dangerous Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-64769</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Process Optimization application suite leverages connection channels/protocols that by-default are not encrypted and could become subject to hijacking or data leakage in certain man-in-the-Middle or passive inspection scenarios.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-64769\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Process Optimization</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Process Optimization: &lt;=2024.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVEVA recommends users take the following action:</p>\n<p><strong>Vendor fix</strong><br>Update to AVEVA Process Optimization v2025</p>\n<p><strong>Mitigation</strong><br>AVEVA alternatively recommends the following actions users can take to mitigate risk:</p>\n<p><strong>Vendor fix</strong><br>Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration.</p>\n<p><strong>Mitigation</strong><br>Apply ACLs to the installation and data folders, limiting write-access to trusted users only.</p>\n<p><strong>Vendor fix</strong><br>Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use.</p>\n<p><strong>Mitigation</strong><br>For more information, please Aveva's security bulletin AVEVA-2026-001.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Christopher Wu of Veracode reported these vulnerabilities to AVEVA</li>\n<li>AVEVA reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this (these) vulnerability(ies), such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-15</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-15</td>\n<td>1</td>\n<td>Initial Republication of AVEVA-2026-001</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 15 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 15 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-06",
        "title": "Siemens SINEC Security Monitor",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SINEC Security Monitor before V4.10.0 contains multiple vulnerabilities. Siemens has released a new version for SINEC Security Monitor and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SINEC Security Monitor are affected:</p>\n<ul>\n<li>SINEC Security Monitor (CVE-2025-40830, CVE-2025-40831)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.7</td>\n<td>Siemens</td>\n<td>Siemens SINEC Security Monitor</td>\n<td>Improper Authorization, Improper Input Validation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40830</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40830\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC Security Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC Security Monitor</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V4.10.0 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/285.html\">CWE-285 Improper Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40831</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40831\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC Security Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC Security Monitor</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V4.10.0 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-882673 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-12-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-12-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-882673 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-07",
        "title": "Siemens RUGGEDCOM APE1808 Devices",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens RUGGEDCOM APE1808 Devices are affected:</p>\n<ul>\n<li>RUGGEDCOM APE1808 (CVE-2025-40891, CVE-2025-40892, CVE-2025-40893, CVE-2025-40898)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.9</td>\n<td>Siemens</td>\n<td>Siemens RUGGEDCOM APE1808 Devices</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40891</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40891\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM APE1808 Devices</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM APE1808</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Contact customer support to receive patch and update information</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40892</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40892\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM APE1808 Devices</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM APE1808</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Contact customer support to receive patch and update information</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.9</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40893</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40893\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM APE1808 Devices</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM APE1808</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Contact customer support to receive patch and update information</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40898</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40898\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM APE1808 Devices</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM APE1808</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Contact customer support to receive patch and update information</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-827968 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-827968 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-09",
        "title": "Siemens Industrial Edge Device Kit",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-09",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-09.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens Industrial Edge Device Kit are affected:</p>\n<ul>\n<li>Industrial Edge Device Kit - arm64 V1.10 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.11 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.12 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.13 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.14 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.15 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.16 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.17 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.18 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.19 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.20 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.21 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.22 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.23 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.24 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.25 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.5 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.6 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.7 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.8 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - arm64 V1.9 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.10 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.11 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.12 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.13 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.14 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.15 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.16 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.17 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.18 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.19 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.20 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.21 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.22 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.23 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.24 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.25 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.5 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.6 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.7 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.8 (CVE-2025-40805)</li>\n<li>Industrial Edge Device Kit - x86-64 V1.9 (CVE-2025-40805)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>Siemens</td>\n<td>Siemens Industrial Edge Device Kit</td>\n<td>Authorization Bypass Through User-Controlled Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40805</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40805\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Industrial Edge Device Kit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Siemens has released new versions for several affected products and advises updating to the latest versions. Siemens recommends specific countermeasures &nbsp;for products where fixes are unavailable or not yet released.</p>\n<p>* Ensure network access to affected products is limited to trusted parties only<br>* Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - x86-64 V1.24: Update to V1.24.2 or later version<br>* Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - x86-64 V1.25: Update to V1.25.1 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-014678 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-014678 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/secure-connectivity-principles-operational-technology-ot",
        "title": "Secure Connectivity Principles for Operational Technology (OT)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/secure-connectivity-principles-operational-technology-ot",
        "summary": "<p>CISA and the UK National Cyber Security Centre (NCSC-UK), in collaboration with federal and international partners, have released <a href=\"https://www.ncsc.gov.uk/collection/operational-technology/secure-connectivity\" target=\"_blank\" data-entity-type=\"external\">Secure Connectivity Principles for Operational Technology (OT)</a> guidance to help asset owners address increasing business and regulatory pressures for connectivity into operational technology (OT) networks.</p>\n<p>This guidance outlines eight principles to use as a framework to design, secure, and manage connectivity into OT environments. These principles are particularly critical for operators of essential services.&nbsp;&nbsp;</p>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/secure-connectivity-principles-operational-technology-ot\" title=\"CISA Product Survey\" data-entity-type=\"external\">CISA Product Survey</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-04",
        "title": "Siemens SIMATIC and SIPLUS products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens SIMATIC and SIPLUS products are affected:</p>\n<ul>\n<li>SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (CVE-2025-40944)</li>\n<li>SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (CVE-2025-40944)</li>\n<li>SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (CVE-2025-40944)</li>\n<li>SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (CVE-2025-40944)</li>\n<li>SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (CVE-2025-40944)</li>\n<li>SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (CVE-2025-40944)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Siemens</td>\n<td>Siemens SIMATIC and SIPLUS products</td>\n<td>Uncontrolled Resource Consumption</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40944</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40944\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SIMATIC and SIPLUS products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p>All affected products: Filter the port 102 of the devices to only accepted connections to/from the IP addresses of machines that are trusted e.g. with an external firewall.</p>\n<p><br>All affected products: Restrict access to the network where S7 communication messages are exchanged.</p>\n<p><br>SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0): Currently no fix is planned</p>\n<p><br>SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): Update to V1.3&nbsp;</p>\n<p><br>SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0): Update to V4.2.2&nbsp;</p>\n<p><br>SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0): Update to V6.0.0&nbsp;</p>\n<p><br>SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0): Update to V6.0.1&nbsp;</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-674753 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-674753 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-03",
        "title": "Siemens TeleControl Server Basic",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>TeleControl Server Basic before V3.1.2.4 contains a local privilege escalation vulnerability that could allow an attacker to run arbitrary code with elevated privileges. Siemens has released a new version for TeleControl Server Basic and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens TeleControl Server Basic are affected:</p>\n<ul>\n<li>TeleControl Server Basic (CVE-2025-40942)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Siemens</td>\n<td>Siemens TeleControl Server Basic</td>\n<td>Execution with Unnecessary Privileges</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Water and Wastewater, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40942</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected application contains a local privilege escalation vulnerability that could allow an attacker to run arbitrary code with elevated privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40942\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens TeleControl Server Basic</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>TeleControl Server Basic &lt;V3.1.2.4</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V3.1.2.4 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/250.html\">CWE-250 Execution with Unnecessary Privileges</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n<li>Peter Cheng of Elex Cybersecurity INC reported this vulnerability to Siemens</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-192617 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-192617 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-08",
        "title": "Siemens Industrial Edge Devices",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Siemens Industrial Edge Devices contain an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens Industrial Edge Devices are affected:</p>\n<ul>\n<li>Industrial Edge Cloud Device (IECD) (CVE-2025-40805)</li>\n<li>Industrial Edge Own Device (IEOD) (CVE-2025-40805)</li>\n<li>Industrial Edge Virtual Device (IEVD) (CVE-2025-40805)</li>\n<li>SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (CVE-2025-40805)</li>\n<li>SCALANCE LPE9433 (6GK5998-3GS11-2AC2) (CVE-2025-40805)</li>\n<li>SIMATIC Automation Workstation 19\" (6AV7256-6CA01-0FP0) (CVE-2025-40805)</li>\n<li>SIMATIC Automation Workstation 24\" (6AV7256-6CA00-0FP0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3MB57-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3QB57-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3UB57-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3XB57-0BX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP700&nbsp;Unified Comfort Panel (6AV2128-3GB06-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0) (CVE-2025-40805)</li>\n<li>SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1) (CVE-2025-40805)</li>\n<li>SIMATIC IOT2050 (6ES7647-0BA00-1YA2) (CVE-2025-40805)</li>\n<li>SIMATIC IPC BX-39A Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC BX-59A Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC127E Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC227E Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC227G Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC427E Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIMATIC IPC847E Industrial Edge Device (CVE-2025-40805)</li>\n<li>SIPLUS HMI MTP1000 Unified Comfort (6AG1128-3KB06-4AX1) (CVE-2025-40805)</li>\n<li>SIPLUS HMI MTP1200 Unified Comfort (6AG1128-3MB06-4AX1) (CVE-2025-40805)</li>\n<li>SIPLUS HMI MTP700 Unified Comfort (6AG1128-3GB06-4AX1) (CVE-2025-40805)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>Siemens</td>\n<td>Siemens Industrial Edge Devices</td>\n<td>Authorization Bypass Through User-Controlled Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40805</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40805\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Industrial Edge Devices</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Industrial Edge Cloud Device (IECD), Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC Automation Workstation 19\" (6AV7256-6CA01-0FP0), SIMATIC Automation Workstation 24\" (6AV7256-6CA00-0FP0), SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1), SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0), SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0), SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1), SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0), SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0), SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3MB57-0BX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1), SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1), SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0), SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0), SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3QB57-0BX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1), SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1), SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0), SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0), SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3UB57-0BX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1), SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1), SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0), SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0), SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio (6AV2128-3XB57-0BX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0), SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0), SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0), SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1), SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1), SIMATIC HMI MTP700&nbsp;Unified Comfort Panel (6AV2128-3GB06-0AX1), SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0), SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0), SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1), SIMATIC IOT2050 (6ES7647-0BA00-1YA2), SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device, SIPLUS HMI MTP1000 Unified Comfort (6AG1128-3KB06-4AX1), SIPLUS HMI MTP1200 Unified Comfort (6AG1128-3MB06-4AX1), SIPLUS HMI MTP700 Unified Comfort (6AG1128-3GB06-4AX1)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p>Ensure network access to affected products is limited to trusted parties only<br>&nbsp;</p>\n<p>SIMATIC Automation Workstation 19\" (6AV7256-6CA01-0FP0), SIMATIC Automation Workstation 24\" (6AV7256-6CA00-0FP0): Currently no fix is available<br>&nbsp;</p>\n<p>Industrial Edge Own Device (IEOD): Update to V1.24.2 or later version<br>&nbsp;</p>\n<p>Industrial Edge Cloud Device (IECD), Industrial Edge Virtual Device (IEVD): Update to V1.24.2 or later version<br>&nbsp;</p>\n<p>SIMATIC IOT2050 (6ES7647-0BA00-1YA2): Update to V1.25.1 or later version<br>&nbsp;</p>\n<p>SCALANCE LPE9413 (6GK5998-3GS01-2AC2): Update to V2.2 or later version<br>&nbsp;</p>\n<p>SCALANCE LPE9433 (6GK5998-3GS11-2AC2): Update to V2.2 or later version<br>&nbsp;</p>\n<p>SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1), SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0), SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0), SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1), SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0), SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0), SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3MB57-0BX0), SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1), SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0), SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1), SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0), SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0), SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3QB57-0BX0), SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1), SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0), SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1), SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0), SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0), SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3UB57-0BX0), SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1), SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0), SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1), SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0), SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0), SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3XB57-0BX0), SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0), SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0), SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0), SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1), SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1), SIMATIC HMI MTP700&nbsp;Unified Comfort Panel (6AV2128-3GB06-0AX1), SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0), SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0), SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1), SIPLUS HMI MTP1000 Unified Comfort (6AG1128-3KB06-4AX1), SIPLUS HMI MTP1200 Unified Comfort (6AG1128-3MB06-4AX1), SIPLUS HMI MTP700 Unified Comfort (6AG1128-3GB06-4AX1): Update to V21 or later version</p>\n<p><br>SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device: Update to V3.1 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-001536 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-001536 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-10",
        "title": "Schneider Electric EcoStruxure Power Build Rapsody",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-10",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-10.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&amp;sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components. Failure to apply the mitigations/remediations provided below may risk memory corruption, heap-based buffer overflow, stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Power Build Rapsody are affected:</p>\n<ul>\n<li>EcoStruxure Power Build Rapsody software (CVE-2025-13844)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Power Build Rapsody</td>\n<td>Double Free, Use After Free</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Critical Manufacturing, Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13844</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13844\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Power Build Rapsody</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Power Build Rapsody software FR 2.8.1 and prior, EcoStruxure Power Build Rapsody software INT 2.8.6 and prior, EcoStruxure Power Build Rapsody software ES 2.8.5 and prior, EcoStruxure Power Build Rapsody software BEL(NL) 2.8.3 and prior, EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Versions FR V2.8.1.0401, INT V2.8.6.200, ES V2.8.5.0301, BEL(NL) V2.8.3.0201, BEL(FR) V2.8.8.0201 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&amp;sourceId=2309 Please restart the service after installing the new version.</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13844: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/415.html\">CWE-415 Double Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13845</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-416: Use After Free vulnerability exists that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13845\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Power Build Rapsody</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Power Build Rapsody software FR 2.8.1.0300 and prior, EcoStruxure Power Build Rapsody software ES 2.8.5.0200 and prior, EcoStruxure Power Build Rapsody software PT 2.8.7.0100 and prior, EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8.0100 and prior, EcoStruxure Power Build Rapsody software BEL(EN) 2.8.3.0100 and prior, EcoStruxure Power Build Rapsody software INT(EN) 2.8.4.0300 and prior, EcoStruxure Power Build Rapsody software NL 2.8.2.0000 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Versions FR V2.8.1.0401, ES V2.8.5.0301, PT V2.8.7.0101, BEL(FR) V2.8.8.0201, BEL(EN) V2.8.3.0201, INT(EN) V2.8.4.0401, NL V2.8.2.000 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13845 vulnerability and are available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&amp;sourceId=2309 Please restart the service after installing the new version.</p>\n<p><strong>Mitigation</strong><br>For CVE-2025-13845: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reporting these vulnerabilities to CISA.</li>\n<li>Rocco Calvi in collaboration with Trend Zero Day Initiative (ZDI) independently reporting these vulnerabilities to CISA.</li>\n<li>Michael Heinzl independently reporting these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-013-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-013-04 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-02",
        "title": "Festo Firmware",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Incomplete Festo product documentation of remote accessible functions and their required IP ports. Depending on the product a description of the supported features can be found in the product documentation to some extent. Update A, 2022-12-13 Added affected device \"Bus module&nbsp;CPX-E-PN, 4080497\"</strong></p>\n<p>Festo reports firmware in the following products is affected:</p>\n<ul>\n<li>Bus module CPX-E-EP: All versions</li>\n<li>Bus module CPX-E-PN: All versions</li>\n<li>Bus node CPX-FB32: All versions</li>\n<li>Bus node CPX-FB33: All versions</li>\n<li>Bus node CPX-FB36: All versions</li>\n<li>Bus node CPX-FB37: All versions</li>\n<li>Bus node CPX-FB39: All versions</li>\n<li>Bus node CPX-FB40: All versions</li>\n<li>Bus node CPX-FB43: All versions</li>\n<li>Bus node CPX-M-FB34: All versions</li>\n<li>Bus node CPX-M-FB35: All versions</li>\n<li>Bus node CPX-M-FB44: All versions</li>\n<li>Bus node CPX-M-FB45: All versions</li>\n<li>Bus node CTEU-EP: All versions</li>\n<li>Bus node CTEU-PN: All versions</li>\n<li>Bus node CTEU-PN-EX1C: All versions</li>\n<li>Camera system CHB-C-N: All versions</li>\n<li>Compact Vision System SBO*-C-*: All versions</li>\n<li>Compact Vision System SBO*-M-*: All versions</li>\n<li>Compact Vision System SBO*-Q-*: All versions</li>\n<li>Control block CPX-CEC: All versions</li>\n<li>Control block CPX-CEC-C1: All versions</li>\n<li>Control block CPX-CEC-C1-V3(All versions): All versions</li>\n<li>Control block CPX-CEC-M1: All versions</li>\n<li>Control block CPX-CEC-M1-V3: All versions</li>\n<li>Control block CPX-CEC-S1-V3: All versions</li>\n<li>Control block CPX-CMXX: All versions</li>\n<li>Control block CPX-FEC-1-IE: All versions</li>\n<li>Controller CECC-D: All versions</li>\n<li>Controller CECC-D-BA: All versions</li>\n<li>Controller CECC-LK: All versions</li>\n<li>Controller CECC-S: All versions</li>\n<li>Controller CECC-X-*: All versions</li>\n<li>Controller CECX-X-C1: All versions</li>\n<li>Controller CECX-X-M1: All versions</li>\n<li>Controller CMXH-ST2-C5-7-DIOP: All versions</li>\n<li>Controller CPX-E-CEC-*: All versions</li>\n<li>Controller SBRD-Q: All versions</li>\n<li>EtherNet/IP interface CPX-AP-I-EP-M12: All versions</li>\n<li>EtherNet/IP interface CPX-AP-I-PN-M12: All versions</li>\n<li>Gateway CPX-IOT: All versions</li>\n<li>Integrated drive EMCA-EC-67-*: All versions</li>\n<li>Motor controller CMMO-ST-C5-1-DION: All versions</li>\n<li>Motor controller CMMO-ST-C5-1-DIOP: All versions</li>\n<li>Motor controller CMMO-ST-C5-1-LKP: All versions</li>\n<li>Motor controller CMMP-AS-*: All versions</li>\n<li>Motor controller CMMT-AS-*: All versions</li>\n<li>Operator unit CDPX-X-A-S-10: All versions</li>\n<li>Operator unit CDPX-X-A-W-13: All versions</li>\n<li>Operator unit CDPX-X-A-W-4: All versions</li>\n<li>Operator unit CDPX-X-A-W-7: All versions</li>\n<li>Planar surface gantry EXCM-*: All versions</li>\n<li>Servo drive CMMT-ST-C8-1C-EP-S0: All versions</li>\n<li>Servo drive CMMT-ST-C8-1C-PN-S0: All versions</li>\n<li>VTEM-S1-*: All versions</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Festo</td>\n<td>Festo Firmware</td>\n<td>Insufficient Technical Documentation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-3270</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple products by Festo a remote unauthenticated attacker could use functions of an&nbsp;undocumented protocol which could lead to a complete loss of confidentiality, integrity and availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-3270\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Firmware</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>&nbsp;Bus module CPX-E-EP: All versions, Bus module CPX-E-PN: All versions, Bus node CPX-FB32: All versions, Bus node CPX-FB33: All versions, Bus node CPX-FB36: All versions, Bus node CPX-FB37: All versions, Bus node CPX-FB39: All versions, Bus node CPX-FB40: All versions, Bus node CPX-FB43: All versions, Bus node CPX-M-FB34: All versions, Bus node CPX-M-FB35: All versions, Bus node CPX-M-FB44: All versions, Bus node CPX-M-FB45: All versions, Bus node CTEU-EP: All versions, Bus node CTEU-PN: All versions, Bus node CTEU-PN-EX1C: All versions, Camera system CHB-C-N: All versions, Compact Vision System SBO*-C-*: All versions, Compact Vision System SBO*-M-*: All versions, Compact Vision System SBO*-Q-*: All versions, Control block CPX-CEC: All versions, Control block CPX-CEC-C1: All versions, Control block CPX-CEC-C1-V3(All versions): All versions, Control block CPX-CEC-M1: All versions, Control block CPX-CEC-M1-V3: All versions, Control block CPX-CEC-S1-V3: All versions, Control block CPX-CMXX: All versions, Control block CPX-FEC-1-IE: All versions, Controller CECC-D: All versions, Controller CECC-D-BA: All versions, Controller CECC-LK: All versions, Controller CECC-S: All versions, Controller CECC-X-*: All versions, Controller CECX-X-C1: All versions, Controller CECX-X-M1: All versions, Controller CMXH-ST2-C5-7-DIOP: All versions, Controller CPX-E-CEC-*: All versions, Controller SBRD-Q: All versions, EtherNet/IP interface CPX-AP-I-EP-M12: All versions, EtherNet/IP interface CPX-AP-I-PN-M12: All versions, Gateway CPX-IOT: All versions, Integrated drive EMCA-EC-67-*: All versions, Motor controller CMMO-ST-C5-1-DION: All versions, Motor controller CMMO-ST-C5-1-DIOP: All versions, Motor controller CMMO-ST-C5-1-LKP: All versions, Motor controller CMMP-AS-*: All versions, Motor controller CMMT-AS-*: All versions, Operator unit CDPX-X-A-S-10: All versions, Operator unit CDPX-X-A-W-13: All versions, Operator unit CDPX-X-A-W-4: All versions, Operator unit CDPX-X-A-W-7: All versions, Planar surface gantry EXCM-*: All versions, Servo drive CMMT-ST-C8-1C-EP-S0: All versions, Servo drive CMMT-ST-C8-1C-PN-S0: All versions, VTEM-S1-*: All versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Update of technical user manual documentation in next product version.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1059.html\">CWE-1059 Insufficient Technical Documentation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CERT@VDE for coordination and support with this publication</li>\n<li>Rob Hulsebos and Daniel dos Santos of Forescout reported this vulnerability to CERT VDE.</li>\n</ul>\n<hr>\n<h2>Impact</h2>\n<p>Please consult the CVE details above.</p>\n<hr>\n<h2>Mitigation</h2>\n<p>Update of technical user manual documentation in next product version.</p>\n<p>Festo has update technical user manual documentation for the next product version to address this issue.</p>\n<p>For more information see the associated Festo SE &amp; Co. KG security advisory <a href=\"https://certvde.com/en/advisories/VDE-2022-041/\" data-entity-type=\"external\">FSA-202209: Festo: Incomplete documentation of remote accessible functions and protocols in Festo products</a>, <a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2022/fsa-202209.json\" data-entity-type=\"external\">FSA-202209: Festo: Incomplete documentation of remote accessible functions and protocols in Festo products - CSAF</a>.</p>\n<hr>\n<h2>Recommendations</h2>\n<p>Users running communication over an untrusted network who require full protection should switch to an alternative solution such as running the communication over a VPN. Festo strongly recommends to minimize and protect network access to connected devices with state of the art techniques and processes. For a secure operation follow the recommendations in the product manuals and note the protocols and their supported features in Festo Field Device Tool or Festo Automation Suite online help. As part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits: - Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside - Use firewalls to protect and separate the control system network from other networks - Use VPN (Virtual Private Networks) tunnels if remote access is required - Activate and apply user management and password features - Use encrypted communication links - Limit the access to both development and control system by physical means, operating system features, etc. - Protect both development and control system by using up to date virus detecting solutions</p>\n<hr>\n<h2>Disclaimer</h2>\n<p>Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment, or liability on the part of Festo.\\n\\nNote: In no case does this information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.\\n\\nIn addition, the actual general terms, and conditions for delivery, payment and software use of Festo, available under http://www.festo.com and the special provisions for the use of Festo Security Advisory available at https://www.festo.com/psirt shall apply.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Festo SE &amp; Co. KG FSA-202209 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Festo SE &amp; Co. KG directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2022-11-29</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-14</td>\n<td>1</td>\n<td>Initial Republication of Festo SE &amp; Co. KG FSA-202209 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-05",
        "title": "Siemens RUGGEDCOM ROS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-015-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Ruggedcom ROS devices contain a temporary denial of service vulnerability that could allow an attacker to crash and restart the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens RUGGEDCOM ROS are affected:</p>\n<ul>\n<li>RUGGEDCOM RMC8388 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RS416Pv2 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RS416v2 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RS900 (32M) V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RS900G (32M) V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2100 (32M) V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2100P (32M) V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2288 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2300 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2300P V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG2488 V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG907R (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG908C (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG909R (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG910C (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSG920P V5.X (CVE-2025-40935)</li>\n<li>RUGGEDCOM RSL910 (CVE-2025-40935)</li>\n<li>RUGGEDCOM RST2228 (CVE-2025-40935)</li>\n<li>RUGGEDCOM RST2228P (CVE-2025-40935)</li>\n<li>RUGGEDCOM RST916C (CVE-2025-40935)</li>\n<li>RUGGEDCOM RST916P (CVE-2025-40935)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 4.3</td>\n<td>Siemens</td>\n<td>Siemens RUGGEDCOM ROS</td>\n<td>Improper Input Validation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40935</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40935\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM ROS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V5.10.1 or later version</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-763474 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-12-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-12-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-01-14</td>\n<td>2</td>\n<td>Initial Republication of Siemens ProductCERT SSA-763474 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Wed, 14 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 14 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/13/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/13/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20805\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-20805</a> Microsoft Windows Information Disclosure Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 13 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 13 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-013-03",
        "title": "YoSmart YoLink Smart Hub",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-013-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-013-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to remotely control other users' smart home devices, intercept sensitive data, and hijack sessions.</strong></p>\n<p>The following versions of YoSmart YoLink Smart Hub are affected:</p>\n<ul>\n<li>YoSmart server (CVE-2025-59449, CVE-2025-59451)</li>\n<li>YoLink Smart Hub (CVE-2025-59452)</li>\n<li>YoLink Mobile Appication (CVE-2025-59448)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.8</td>\n<td>YoSmart</td>\n<td>YoSmart YoLink Smart Hub</td>\n<td>Incorrect Authorization, Generation of Predictable Numbers or Identifiers, Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-59449</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The YoSmart YoLink MQTT broker through 2025-10-02 does not enforce sufficient authorization controls to prevent cross-account attacks, allowing an attacker to remotely operate affected devices if the attacker obtains the associated device IDs. Because YoLink device IDs are predictable, an attacker can exploit this to gain full control over any other YoLink user's devices.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59449\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>YoSmart YoLink Smart Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>YoSmart</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>YoSmart server: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>YoSmart recommends that users take the following actions to mitigate these vulnerabilities:</p>\n<p><strong>Mitigation</strong><br>CVE-2025-59449 &amp; CVE-2025-59451 - YoSmart's engineering team resolved these vulnerabilities on the server backend. No user actions are required</p>\n<p><strong>Mitigation</strong><br>For more information visit the YoSmart Security Advisory.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/863.html\">CWE-863 Incorrect Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-59452</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The YoSmart YoLink API through 2025-10-02 uses an endpoint URL that is derived from a device's MAC address along with an MD5 hash of non-secret information, such as a key that begins with cf50.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59452\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>YoSmart YoLink Smart Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>YoSmart</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>YoSmart YoLink Smart Hub: 0382</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>YoSmart recommends that users take the following actions to mitigate these vulnerabilities:</p>\n<p><strong>Mitigation</strong><br>CVE-2025-59452 - YoSmart released update 0383 to support a new, dynamic authentication algorithm. This will be released as an automatic over-the-air update and no user action is required.</p>\n<p><strong>Mitigation</strong><br>For more information visit the YoSmart Security Advisory.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/340.html\">CWE-340 Generation of Predictable Numbers or Identifiers</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-59448</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Mobile Application 1.40.41 and YoLink MQTT Broker.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59448\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>YoSmart YoLink Smart Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>YoSmart</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>YoSmart YoLink Mobile Appication: &lt;v1.40.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>YoSmart recommends that users take the following actions to mitigate these vulnerabilities:</p>\n<p><strong>Mitigation</strong><br>CVE-2025-59448 - YoSmart recommends that users update to version 1.40.45 or later to mitigate this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information visit the YoSmart Security Advisory.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-59451</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The YoSmart YoLink application through 2025-10-02 has session tokens with unexpectedly long lifetimes.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59451\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>YoSmart YoLink Smart Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>YoSmart</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>YoSmart server: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>YoSmart recommends that users take the following actions to mitigate these vulnerabilities:</p>\n<p><strong>Mitigation</strong><br>CVE-2025-59449 &amp; CVE-2025-59451 - YoSmart's engineering team resolved these vulnerabilities on the server backend. No user actions are required</p>\n<p><strong>Mitigation</strong><br>For more information visit the YoSmart Security Advisory.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/863.html\">CWE-863 Incorrect Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.5</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Nick Cerne of Bishop Fox reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 13 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 13 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-013-02",
        "title": "Rockwell Automation FactoryTalk DataMosaix Private Cloud",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-013-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-013-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to perform unauthorized sensitive database operations.</strong></p>\n<p>The following versions of Rockwell Automation FactoryTalk DataMosaix Private Cloud are affected:</p>\n<ul>\n<li>FactoryTalk DataMosaix Private Cloud (CVE-2025-12807)</li>\n<li>FactoryTalk DataMosaix Private Cloud (CVE-2025-12807)</li>\n<li>FactoryTalk DataMosaix Private Cloud (CVE-2025-12807)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation FactoryTalk DataMosaix Private Cloud</td>\n<td>Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-12807</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue was discovered in DataMosaix Private Cloud, allowing users with low privilege to perform sensitive database operations through exposed Application Programming Interface (API) endpoints.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-12807\" data-entity-type=\"external\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk DataMosaix Private Cloud</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk DataMosaix Private Cloud: 7.11, Rockwell Automation FactoryTalk DataMosaix Private Cloud: 8.00, Rockwell Automation FactoryTalk DataMosaix Private Cloud: 8.01</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation encourages users of the affected software to apply the following risk mitigations, if possible:</p>\n<p><strong>Vendor fix</strong><br>Update FactoryTalk DataMosaix Private Cloud to Version 8.01.02 or later.</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's best security practices.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Initial republication of Rockwell Automation advisory 'FactoryTalk DataMosaix Private Cloud SQL Injection'</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 13 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 13 Jan 26 12:00:00 +0000"
    }
]