· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Process Expert

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure™ Process Expert for AVEVA System Platform product enables users to…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure™ Process Expert for AVEVA System Platform product enables users to achieve operational profitability from design engineering to meeting the demands of modern-day production. It provides an asset centric and object-oriented automation platform to deploy system-wide standards in a digital ecosystem. Failure to apply the Fix/Mitigations provided below may risk modification of the executable binaries, which could result in privilege escalation. The following versions of Schneider Electric are affected: EcoStruxure™ Process Expert (CVE-2025-13905) CVSS Vendor Equipment Vulnerabilities v3 7.3 Schneider Electric Schneider Electric EcoStruxure Process Expert Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13905 CWE-276 : Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart. View CVE Details Affected Products Schneider Electric Vendor: Schneider Electric Product Version: EcoStruxure™ Process Expert versions prior to 2025, EcoStruxure™ Process Expert All Versions Product Status: fixed, known_affected Remediations Vendor fix Version 2025 of EcoStruxure™ Process Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert Mitigation Schneider Electric is establishing a remediation plan for all the future versions of EcoStruxure™™ Process Expert for AVEVA System Platform that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: • Recommended to apply application whitelisting at system level to allow execution of authenticated applications. More details available here: https://www.se.com/ww/en/download/document/EIO0000004778/ • Recommended to allow access to the system only to the required users. Relevant CWE: CWE-276 Incorrect Default Permissions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. Charit Misra of DNV Cyber reported this vulnerability to Schneider Electric General Security Recommendations We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-013-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Original Release 2026-01-22 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-013-02 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AutomationDirect CLICK Programmable Logic Controller

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to impersonate users, escalate privileges, gain unauthorized access to systems and services, and decrypt sensitive data. The following versions of AutomationDirect CLICK Programmable Logic Controller are affected: CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CLICK Programmable Logic Controller…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to impersonate users, escalate privileges, gain unauthorized access to systems and services, and decrypt sensitive data. The following versions of AutomationDirect CLICK Programmable Logic Controller are affected: CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CVSS Vendor Equipment Vulnerabilities v3 6.1 AutomationDirect AutomationDirect CLICK Programmable Logic Controller Weak Encoding for Password, Plaintext Storage of a Password Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-67652 An attacker with access to the project file could use the exposed credentials to impersonate users, escalate privileges, or gain unauthorized access to systems and services. The absence of robust encryption or secure handling mechanisms increases the likelihood of this type of exploitation, leaving sensitive information more vulnerable. View CVE Details Affected Products AutomationDirect CLICK Programmable Logic Controller Vendor: AutomationDirect Product Version: AutomationDirect CLICK Programmable Logic Controller: C0-0x, AutomationDirect CLICK Programmable Logic Controller: C0-1x, AutomationDirect CLICK Programmable Logic Controller: C2-x Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update CLICK PLUS and firmware to V3.90. Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed: Mitigation Network Isolation – Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Secure Communications – Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Access Control – Restrict both physical and logical access to authorized personnel only. Mitigation Application Whitelisting – Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Endpoint Protection – Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Logging & Monitoring – Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Backup & Recovery – Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Ongoing Risk Assessment – Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-261 Weak Encoding for Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N CVE-2025-25051 An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks. View CVE Details Affected Products AutomationDirect CLICK Programmable Logic Controller Vendor: AutomationDirect Product Version: AutomationDirect CLICK Programmable Logic Controller: C0-0x, AutomationDirect CLICK Programmable Logic Controller: C0-1x, AutomationDirect CLICK Programmable Logic Controller: C2-x Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update CLICK PLUS and firmware to V3.90. Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed: Mitigation Network Isolation – Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Secure Communications – Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Access Control – Restrict both physical and logical access to authorized personnel only. Mitigation Application Whitelisting – Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Endpoint Protection – Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Logging & Monitoring – Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Backup & Recovery – Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Ongoing Risk Assessment – Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-256 Plaintext Storage of a Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N Acknowledgments Dylan Chambers Bourgeois of Triskele Labs reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-01-22 Date Revision Summary 2026-01-22 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20045 Cisco Unified Communications Products Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20045 Cisco Unified Communications Products Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Foxboro DCS

View CSAF Summary Schneider Electric is aware of a vulnerability disclosed by INTEL used in the EcoStruxure™ Foxboro DCS product formerly known as Foxboro Evo Process Automation System and I/A Series. The [EcoStruxure™ Foxboro DCS product](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/#overview) is an innovative family of fault-tolerant, highly available control components, which consolidates…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability disclosed by INTEL used in the EcoStruxure™ Foxboro DCS product formerly known as Foxboro Evo Process Automation System and I/A Series. The [EcoStruxure™ Foxboro DCS product](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/#overview) is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediations provided below may risk allowing an authenticated user to potentially enable information disclosure via a side channel with local access, which could result in loss of system functionality or unauthorized access to system functions. The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected: EcoStruxure™ Foxboro DCS Virtualization Server () EcoStruxure™ Foxboro DCS Virtualization Server () EcoStruxure™ Foxboro DCS Standard Workstation () EcoStruxure™ Foxboro DCS Standard Workstation () CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric EcoStruxure Foxboro DCS Exposure of Sensitive Information to an Unauthorized Actor Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2018-12130 A vulnerability disclosed by INTEL in Intel Xeon Silver 4110 and Intel Xeon W-2123 and prior impact Schneider Electric EcoStruxure™ Foxboro DCS V91 DCS Virtualization Server and H92 DCS Standard Workstation. View CVE Details Affected Products Schneider Electric EcoStruxure Foxboro DCS Vendor: Schneider Electric Product Version: Product Status: fixed, known_affected Remediations Vendor fix Upgrade to the latest Foxboro server (V95) and workstations (Dell D96): Please contact your local Service Representative or Schneider Electric Process Automation Global Customer Support Center for information on how to migrate to new hardware. https://pasupport.schneider-electric.com/home2020.asp?code=i1swrtYD1O7YcWYkLo5iZJHxEEY9U-agDBBtcLSP7EXks Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The BIOS, OS security patches are applied to significantly reduce the exploit possibility. Additional information is available here: https://se.my.site.com/PAkb/s/article/KA000127385 Several layers of defense-in-depth mechanisms available in the recommended security architecture of DCS system, including the computers themselves, and by following the General Security Recommendations specified below mitigate this vulnerability. https://pasupport.schneider-electric.com/Content/Documents/IASeries/b0700_lastrev/b0700hz_f.pdf Relevant CWE: CWE-200 Exposure of Sensitive Information to an Unauthorized Actor Metrics CVSS Version Base Score Base Severity Vector String 3.0 6.5 MEDIUM CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-343-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-12-09 Date Revision Summary 2025-12-09 1 Original Release 2026-01-20 2 Initial Republication of Schneider Electric CPCERT SEVD-2025-343-01 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Verve Asset Manager

View CSAF Summary Successful exploitation of these vulnerabilities may allow an attacker to access sensitive information stored in variables within the ADI server. The following versions of Rockwell Automation Verve Asset Manager are affected: Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities may allow an attacker to access sensitive information stored in variables within the ADI server. The following versions of Rockwell Automation Verve Asset Manager are affected: Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) Verve Asset Manager (CVE-2025-14376, CVE-2025-14377) CVSS Vendor Equipment Vulnerabilities v3 7.9 Rockwell Automation Rockwell Automation Verve Asset Manager Insecure Storage of Sensitive Information, Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-14376 A security issue was discovered within the legacy ADI server component of Verve Asset Manager, where unencrypted sensitive data was stored in environment variables. This component was retired and became optional beginning with the 1.36 release in 2024. View CVE Details Affected Products Rockwell Automation Verve Asset Manager Vendor: Rockwell Automation Product Version: Rockwell Automation Verve Asset Manager: 1.33, Rockwell Automation Verve Asset Manager: 1.34, Rockwell Automation Verve Asset Manager: 1.35, Rockwell Automation Verve Asset Manager: 1.36, Rockwell Automation Verve Asset Manager: 1.37, Rockwell Automation Verve Asset Manager: 1.38, Rockwell Automation Verve Asset Manager: 1.39, Rockwell Automation Verve Asset Manager: 1.40, Rockwell Automation Verve Asset Manager: 1.41, Rockwell Automation Verve Asset Manager: 1.41.1, Rockwell Automation Verve Asset Manager: 1.41.2, Rockwell Automation Verve Asset Manager: 1.41.3 Product Status: known_affected Remediations Mitigation Rockwell Automation reports that the issue was resolved in version 1.42, and the component has been optional since version 1.36. Rockwell Automation recommends updating to the latest available version. Mitigation For additional details, refer to the advisory on the Rockwell Automation security page. Mitigation For further assistance, contact Rockwell Automation TechConnect for help. Relevant CWE: CWE-922 Insecure Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N CVE-2025-14377 A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager. The issue occurred because unencrypted sensitive information was incorrectly stored during playbook execution. This component was retired and became optional starting with the 1.36 release in 2024. View CVE Details Affected Products Rockwell Automation Verve Asset Manager Vendor: Rockwell Automation Product Version: Rockwell Automation Verve Asset Manager: 1.33, Rockwell Automation Verve Asset Manager: 1.34, Rockwell Automation Verve Asset Manager: 1.35, Rockwell Automation Verve Asset Manager: 1.36, Rockwell Automation Verve Asset Manager: 1.37, Rockwell Automation Verve Asset Manager: 1.38, Rockwell Automation Verve Asset Manager: 1.39, Rockwell Automation Verve Asset Manager: 1.40, Rockwell Automation Verve Asset Manager: 1.41, Rockwell Automation Verve Asset Manager: 1.41.1, Rockwell Automation Verve Asset Manager: 1.41.2, Rockwell Automation Verve Asset Manager: 1.41.3 Product Status: known_affected Remediations Mitigation Rockwell Automation reports that the issue was resolved in version 1.42, and the component has been optional since version 1.36. Rockwell Automation recommends updating to the latest available version. Mitigation For additional details, refer to the advisory on the Rockwell Automation security page. Mitigation For further assistance, contact Rockwell Automation TechConnect for help. Relevant CWE: CWE-312 Cleartext Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.9 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:L Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-01-20 Date Revision Summary 2026-01-20 1 Initial Republication of Rockwell Automation's security advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric devices using CODESYS Runtime

View CSAF Summary Schneider Electric is aware of multiple vulnerabilities disclosed on CODESYS runtime system V3 communication server. Many vendors, including Schneider Electric, embed CODESYS in their offers. If successfully exploited, these vulnerabilities could result in a denial of service or, in some cases, in remote code execution on PacDrive controllers, Modicon Controllers M241 / M251 / M262 / M258 / LMC058…
Read full source summary
View CSAF Summary Schneider Electric is aware of multiple vulnerabilities disclosed on CODESYS runtime system V3 communication server. Many vendors, including Schneider Electric, embed CODESYS in their offers. If successfully exploited, these vulnerabilities could result in a denial of service or, in some cases, in remote code execution on PacDrive controllers, Modicon Controllers M241 / M251 / M262 / M258 / LMC058 / LMC078 / M218 , HMISCU, the Simulation Runtime SoftSPS from EcoStruxure Machine Expert and EcoStruxure Microgrid Operation products. Failure to apply the mitigations provided below may result in denial of service and/or arbitrary remote code execution. The following versions of Schneider Electric devices using CODESYS Runtime are affected: HMISCU Controller (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller LMC078 (CVE-2022-4046, CVE-2023-28355) Modicon Controller M241 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller M251 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller M262 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller M258 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller LMC058 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Modicon Controller M218 (CVE-2022-4046, CVE-2023-28355) PacDrive 3 Controllers: LMC Eco/Pro/Pro2 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) SoftSPS embedded in EcoStruxure Machine Expert (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Vijeo Designer embedded in EcoStruxure Machine Expert (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) HMISCU Controller () Modicon Controller M241 () Modicon Controller M251 () Modicon Controller M262 () PacDrive 3 Controllers: LMC Eco/Pro/Pro2 () SoftSPS embedded in EcoStruxure Machine Expert () Vijeo Designer embedded in EcoStruxure Machine Expert () Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series iPC series with Vijeo Designer runtime () Vijeo Designer Basic () Harmony iPC series () Magelis XBT series (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Easy Modicon M310 (CVE-2022-4046, CVE-2023-28355, CVE-2022-47378, CVE-2022-47379, CVE-2022-47380, CVE-2022-47381, CVE-2022-47382, CVE-2022-47383, CVE-2022-47384, CVE-2022-47386, CVE-2022-47387, CVE-2022-47388, CVE-2022-47389, CVE-2022-47390, CVE-2022-47385, CVE-2022-47392, CVE-2022-47393, CVE-2022-47391, CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550, CVE-2023-37551, CVE-2023-37552, CVE-2023-37553, CVE-2023-37554, CVE-2023-37555, CVE-2023-37556, CVE-2023-37557, CVE-2023-37558, CVE-2023-37559, CVE-2023-3662, CVE-2023-3663, CVE-2023-3669, CVE-2023-3670) Harmony P6 series () Vijeo Designer runtime () Vijeo Designer runtime () Easy Modicon M310 () CVSS Vendor Equipment Vulnerabilities v3 8.8 Schneider Electric Schneider Electric devices using CODESYS Runtime Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Validation of Integrity Check Value, Improper Validation of Consistency within Input, Out-of-bounds Write, Stack-based Buffer Overflow, Untrusted Pointer Dereference, Improper Input Validation, Files or Directories Accessible to External Parties, Uncontrolled Search Path Element, Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Improper Restriction of Excessive Authentication Attempts, Exposure of Resource to Wrong Sphere Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2022-4046 In addition to the functionality described above, there are memory access functions that allow the PLC application code to read or write memory. These are not limited to the data memories that are assigned to it or allocated by it. For this reason, the PLC application code can potentially access the entire RAM memory of the CODESYS Control runtime process surrounding it. This could allow PLC programmers who have successfully authenticated themselves at the controller to execute PLC application code that can modify itself or read or write sensitive data of the CODESYS Control runtime process. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller LMC078 All Versions, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric Modicon Controller M218 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. No fix planned Schneider Electric´s Modicon LMC078 controllers have reached end of their life and are no longer commercially available. They have been replaced by the Modicon M262 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information. No fix planned Schneider Electric’s Modicon M218 controllers have reached their end of life and are no longer commercially available. They have been replaced by the Modicon Easy M200 and Modicon M241 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2023-28355 The PLC application code executed by the CODESYS Control Runtime contains a checksum. This enables the CODESYS development system to check at login whether its loaded project matches the PLC application code executed on the controller. This checksum is not sufficient to reliably detect PLC application code that has been modified in memory or boot application files that have been manipulated. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller LMC078 All Versions, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric Modicon Controller M218 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. No fix planned Schneider Electric´s Modicon LMC078 controllers have reached end of their life and are no longer commercially available. They have been replaced by the Modicon M262 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information. No fix planned Schneider Electric’s Modicon M218 controllers have reached their end of life and are no longer commercially available. They have been replaced by the Modicon Easy M200 and Modicon M241 controllers. We recommend our customers to migrate to the latest offer. Please contact your local Schneider Electric technical support for more information. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-354 Improper Validation of Integrity Check Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N CVE-2022-47378 After successful authentication, specific crafted communication requests with inconsistent content can cause the CmpFiletransfer component to read internally from an invalid address, potentially leading to a denial-of-service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-1288 Improper Validation of Consistency within Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47379 After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to memory, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47380 After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47381 After successful authentication, specific crafted communication requests can cause the CmpApp component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47382 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47383 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47384 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47386 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47387 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47388 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47389 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47390 After successful authentication, specific crafted communication requests can cause the CmpTraceMgr component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47385 After successful authentication, specific crafted communication requests can cause the CmpAppForce component to write attacker-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47392 After successful authentication, specific crafted communication requests with inconsistent content can cause the CmpApp/CmpAppBP/CmpAppForce components to read internally from an invalid address, potentially leading to a denial-of-service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-1288 Improper Validation of Consistency within Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47393 After successful authentication, specific crafted communication requests can cause the CmpFiletransfer component to dereference addresses provided by the request for internal read access, which can lead to a denial-of-service situation. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-822 Untrusted Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47391 Crafted communication requests can cause the affected products to read internally from an invalid address, potentially leading to a denial-of-service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-1288 Improper Validation of Consistency within Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2023-37545 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37546 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37547 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37548 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37549 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37550 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-ofservice condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37551 After successful authentication as a user, specially crafted communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N CVE-2023-37552 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37553 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37554 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37555 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37556 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37557 After successful authentication as a user, specific crafted communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37558 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37559 After successful authentication as a user, specific crafted communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of service condition. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-3662 The CODESYS Development System is vulnerable to the execution of malicious binaries from the current working directory. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2023-3663 The Notification Center of the CODESYS Development System receives messages without ensuring that the message was not modified during transmission. This finally enables MITMs code execution when the user clicks the Learn More button. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2023-3669 The Notification Center of the CODESYS Development System receives messages without ensuring that the message was not modified during transmission. This finally enables MITMs code execution when the user clicks the Learn More button. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.3 LOW CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N CVE-2023-3670 CODESYS Scripting executes potentially malicious scripts saved by another user. View CVE Details Affected Products Schneider Electric devices using CODESYS Runtime Vendor: Schneider Electric Product Version: Schneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18, Schneider Electric Modicon Controller M251 All Versions prior to v5.2.11.18, Schneider Electric Modicon Controller M262 All versions prior to v5.2.8.12, Schneider Electric Modicon Controller M258 All Versions, Schneider Electric Modicon Controller LMC058 All Versions, Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 All versions prior to v1.76.14.1, Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert All Versions prior to Machine Expert v2.2, Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert All versions prior to v6.3.1, Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series All Versions prior to V6.3 HF3, Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU all versions prior to v2.0 HF2, Schneider Electric Magelis XBT series All Versions, Schneider Electric Easy Modicon M310 All versions prior to v3.1.5.82 Product Status: fixed, known_affected Remediations Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1. Vendor fix Modicon Controller M241 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M241 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M251 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M251 to the latest Firmware and preform reboot. Vendor fix Modicon Controller M262 Firmware delivered with Machine Expert v2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2 of Machine Expert. Update Modicon Controller M262 to the latest firmware and preform reboot. No fix planned Schneider Electric’s Magelis XBT series have reached their end of commercialization. Magelis XBTGT/XBTGK offers have been replaced by HMIGTO/HMIGTU/HMIGK. We recommend our customers to migrate to the latest offers. For Magelis XBT series that haven't been replaced, please contact your local Schneider Electric technical support for more information. Vendor fix PacDrive 3 Controllers LMC Eco/Pro/Pro2 Firmware delivered with Machine Expert V2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to V2.2 of Machine Expert. Update PacDrive 3 Controllers: LMC Eco/Pro/Pro2 to the latest Firmware and preform reboot. Vendor fix Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. Vendor fix SoftSPS component has been removed from Machine Expert V2.2. Machine Expert can be updated through the Schneider Electric Software Update (SESU) application. Mitigation • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Use encrypted communication links. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide mitigations through the activation of project encryption in the Enhanced Security Settings, chapter https://download.schneiderelectric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. • Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/1105. Mitigation • Enable the optional ‘Implicit Checks’ on logic applications. • Avoid use of the POINTER data type and MEMMOVE instructions, especially on untrusted inputs. • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. • Use firewalls to protect and separate the control system network from other networks. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp Vendor fix Version 3.1.5.82 includes a fix for this vulnerability and can be download here: https://www.se.com/ww/en/product-range/268959560-easy-modicon-m310 As an alternative, contact your Schneider Electric Customer Care Center to obtain the firmware. To complete the update, connect to M310 and download the firmware using EcoStruxureTM Motion Expert. Vendor fix Version 6.3 HF3 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Hot Fix. For additional detail please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 HF3 of Vijeo Designer. Vendor fix Vijeo Designer Basic v2.0 HotFix 2 includes a fix for this vulnerability. Please contact your Schneider Electric Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic. Vendor fix Version 6.3 SP2 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware As an alternative, please contact your Schneider Electric Customer Care Center to obtain the Fix. For additional details, please refer to the supplied help file in Hot Fix. On the engineering workstation, update to v6.3 SP2 of Vijeo Designer. Mitigation Customers should immediately apply the following mitigations to reduce the risk of exploitation: • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.• Restrict access to programming ports, typically UDP/1740, TCP/11740 and TCP/484.• Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.• Use firewalls to protect and separate the control system network from other networks.• Use VPN (Virtual Private Networks) tunnels if remote access is required. • Limit the access to both development and control system by physical means, operating system features, etc. • Protect both development and control system by using up to date malware protection. Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reported these vulnerabilities to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider’s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. Details Vulnerabilities disclosed by CODESYSTM group in the CODESYS Runtime and Simulation Runtime impact Schneider Electric controller products and software. Additional information about the vulnerabilities can be found in the CODESYSTM Advisories at: Advisory 2023-02 • Advisory 2023-03 • Advisory 2023-04 • Advisory 2023-05 • Advisory 2023-06 • Advisory 2023-07 • Advisory 2023-08 • Advisory 2023-09 Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2023-192-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2023-07-11 Date Revision Summary 2023-07-11 1 Original Release 2023-08-08 2 New CODESYS advisories 2023-04 to 2023-09 added. Additional impacted product: Harmony and Easy Harmony, Vijeo Designer embedded in EcoStruxure Machine Expert. 2024-01-09 3 Remediations added for different products. 2024-03-12 4 A remediation is now available for HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series 2024-04-09 5 A remediation is now available for Easy Harmony HMIET6/HMIFT6, and Magelis HMIGXU series 2024-06-11 6 Easy Modicon M310 is added to the list of products impacted 2025-08-12 7 Remediations are available for Harmony iPC series and Harmony P6 series with Vijeo Designer. 2025-11-11 8 Remediation is available for Easy Modicon M310. 2025-12-09 9 Replaced advisory IDs with CVE IDs. Added vulnerability details, including CVE descriptions, CWE identifiers, CVSS scores, and vector strings. Corrected mappings of affected and fixed products for each CVE. 2026-01-20 10 Initial Republication of Schneider Electric CPCERT SEVD-2023-192-04 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AVEVA Process Optimization

View CSAF Summary Successful exploitation of these vulnerabilities could enable an attacker to execute remote code, perform SQL injection, escalate privileges, or access sensitive information. The following versions of AVEVA Process Optimization are affected: Process Optimization (CVE-2025-61937, CVE-2025-64691, CVE-2025-61943, CVE-2025-65118, CVE-2025-64729, CVE-2025-65117, CVE-2025-64769) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable an attacker to execute remote code, perform SQL injection, escalate privileges, or access sensitive information. The following versions of AVEVA Process Optimization are affected: Process Optimization (CVE-2025-61937, CVE-2025-64691, CVE-2025-61943, CVE-2025-65118, CVE-2025-64729, CVE-2025-65117, CVE-2025-64769) CVSS Vendor Equipment Vulnerabilities v3 10 AVEVA AVEVA Process Optimization Improper Control of Generation of Code ('Code Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Uncontrolled Search Path Element, Missing Authorization, Use of Potentially Dangerous Function, Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-61937 The vulnerability, if exploited, could allow an unauthenticated miscreant to achieve remote code execution under OS System privileges of "taoimr" service, potentially resulting in complete compromise of the Model Application Server. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2025-64691 The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to tamper with TCL Macro scripts and escalate privileges to OS System, potentially resulting in complete compromise of the Model Application Server. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-61943 The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Standard User) to tamper with queries in Captive Historian and achieve code execution under SQL Server administrative privileges, potentially resulting in complete compromise of the SQL Server. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.4 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N CVE-2025-65118 The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to trick Process Optimization services into loading arbitrary code and escalate privileges to OS System, potentially resulting in complete compromise of the Model Application Server. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-64729 The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to tamper with Process Optimization project files, embed code, and escalate their privileges to the identity of a victim user who subsequently interacts with the project files. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L CVE-2025-65117 The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Designer User) to embed OLE objects into graphics, and escalate their privileges to the identity of a victim user who subsequently interacts with the graphical elements. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-676 Use of Potentially Dangerous Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N CVE-2025-64769 The Process Optimization application suite leverages connection channels/protocols that by-default are not encrypted and could become subject to hijacking or data leakage in certain man-in-the-Middle or passive inspection scenarios. View CVE Details Affected Products AVEVA Process Optimization Vendor: AVEVA Product Version: AVEVA Process Optimization: <=2024.1 Product Status: known_affected Remediations Mitigation AVEVA recommends users take the following action: Vendor fix Update to AVEVA Process Optimization v2025 Mitigation AVEVA alternatively recommends the following actions users can take to mitigate risk: Vendor fix Apply Host and/or Network firewall rules restricting the taoimr service to accept traffic only from trusted source(s). By default, AVEVA Process Optimization listens on port 8888/8889(TLS). Please refer to the AVEVA Process Optimization Installation Guide for additional details on ports configuration. Mitigation Apply ACLs to the installation and data folders, limiting write-access to trusted users only. Vendor fix Maintain a trusted chain-of-custody on Process Optimization project files during creation, modification, distribution, backups, and use. Mitigation For more information, please Aveva's security bulletin AVEVA-2026-001. Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L Acknowledgments Christopher Wu of Veracode reported these vulnerabilities to AVEVA AVEVA reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this (these) vulnerability(ies), such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-01-15 Date Revision Summary 2026-01-15 1 Initial Republication of AVEVA-2026-001 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SIMATIC and SIPLUS products

View CSAF Summary Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends…
Read full source summary
View CSAF Summary Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC and SIPLUS products are affected: SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (CVE-2025-40944) SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (CVE-2025-40944) SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (CVE-2025-40944) SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (CVE-2025-40944) SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (CVE-2025-40944) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens SIMATIC and SIPLUS products Uncontrolled Resource Consumption Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40944 Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation. View CVE Details Affected Products Siemens SIMATIC and SIPLUS products Vendor: Siemens Product Version: SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) Product Status: known_affected Remediations Mitigation Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk: All affected products: Filter the port 102 of the devices to only accepted connections to/from the IP addresses of machines that are trusted e.g. with an external firewall. All affected products: Restrict access to the network where S7 communication messages are exchanged. SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0): Currently no fix is planned SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): Update to V1.3 SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0): Update to V4.2.2 SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0): Update to V6.0.0 SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0): Update to V6.0.1 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-674753 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Publication Date 2026-01-14 2 Initial Republication of Siemens ProductCERT SSA-674753 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Power Build Rapsody

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components.…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components. Failure to apply the mitigations/remediations provided below may risk memory corruption, heap-based buffer overflow, stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code. The following versions of Schneider Electric EcoStruxure Power Build Rapsody are affected: EcoStruxure Power Build Rapsody software (CVE-2025-13844) CVSS Vendor Equipment Vulnerabilities v3 7.8 Schneider Electric Schneider Electric EcoStruxure Power Build Rapsody Double Free, Use After Free Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13844 CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody. View CVE Details Affected Products Schneider Electric EcoStruxure Power Build Rapsody Vendor: Schneider Electric Product Version: EcoStruxure Power Build Rapsody software FR 2.8.1 and prior, EcoStruxure Power Build Rapsody software INT 2.8.6 and prior, EcoStruxure Power Build Rapsody software ES 2.8.5 and prior, EcoStruxure Power Build Rapsody software BEL(NL) 2.8.3 and prior, EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8 and prior Product Status: fixed, known_affected Remediations Vendor fix Versions FR V2.8.1.0401, INT V2.8.6.200, ES V2.8.5.0301, BEL(NL) V2.8.3.0201, BEL(FR) V2.8.8.0201 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309 Please restart the service after installing the new version. Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: For CVE-2025-13844: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project Relevant CWE: CWE-415 Double Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L CVE-2025-13845 CWE-416: Use After Free vulnerability exists that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody. View CVE Details Affected Products Schneider Electric EcoStruxure Power Build Rapsody Vendor: Schneider Electric Product Version: EcoStruxure Power Build Rapsody software FR 2.8.1.0300 and prior, EcoStruxure Power Build Rapsody software ES 2.8.5.0200 and prior, EcoStruxure Power Build Rapsody software PT 2.8.7.0100 and prior, EcoStruxure Power Build Rapsody software BEL(FR) 2.8.8.0100 and prior, EcoStruxure Power Build Rapsody software BEL(EN) 2.8.3.0100 and prior, EcoStruxure Power Build Rapsody software INT(EN) 2.8.4.0300 and prior, EcoStruxure Power Build Rapsody software NL 2.8.2.0000 and prior Product Status: fixed, known_affected Remediations Vendor fix Versions FR V2.8.1.0401, ES V2.8.5.0301, PT V2.8.7.0101, BEL(FR) V2.8.8.0201, BEL(EN) V2.8.3.0201, INT(EN) V2.8.4.0401, NL V2.8.2.000 of EcoStruxure Power Build Rapsody includes a fix for the CVE-2025-13845 vulnerability and are available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309 Please restart the service after installing the new version. Mitigation For CVE-2025-13845: - Only open projects from trusted sources - Ensure use of Malware scans before opening any externally created Project Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reporting these vulnerabilities to CISA. Rocco Calvi in collaboration with Trend Zero Day Initiative (ZDI) independently reporting these vulnerabilities to CISA. Michael Heinzl independently reporting these vulnerabilities to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-013-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Original Release 2026-01-14 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-013-04 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Secure Connectivity Principles for Operational Technology (OT)

CISA and the UK National Cyber Security Centre (NCSC-UK), in collaboration with federal and international partners, have released Secure Connectivity Principles for Operational Technology (OT) guidance to help asset owners address increasing business and regulatory pressures for connectivity into operational technology (OT) networks. This guidance outlines eight principles to use as a framework to design, secure,…
Read full source summary
CISA and the UK National Cyber Security Centre (NCSC-UK), in collaboration with federal and international partners, have released Secure Connectivity Principles for Operational Technology (OT) guidance to help asset owners address increasing business and regulatory pressures for connectivity into operational technology (OT) networks. This guidance outlines eight principles to use as a framework to design, secure, and manage connectivity into OT environments. These principles are particularly critical for operators of essential services. Please share your thoughts! We welcome your feedback. CISA Product Survey