[
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-01",
        "title": "TP-Link Systems Inc. VIGI Series IP Camera",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in unauthorized users gaining administrative access to affected closed circuit television cameras.</strong></p>\n<p>The following versions of TP-Link Systems Inc. VIGI Series IP Camera are affected:</p>\n<ul>\n<li>VIGI Cx45 Series Models C345, C445 &lt;=3.1.0_Build_250820_Rel.57668n (CVE-2026-0629)</li>\n<li>VIGI Cx55 Series Models C355, C455 &lt;=3.1.0_Build_250820_Rel.58873n (CVE-2026-0629)</li>\n<li>VIGI Cx85 Series Models C385, C485 &lt;=3.0.2_Build_250630_Rel.71279n (CVE-2026-0629)</li>\n<li>VIGI C340S Series &lt;=3.1.0_Build_250625_Rel.65381n (CVE-2026-0629)</li>\n<li>VIGI C540S Series Models C540S, EasyCam C540S &lt;=3.1.0_Build_250625_Rel.66601n (CVE-2026-0629)</li>\n<li>VIGI C540V Series &lt;=2.1.0_Build_250702_Rel.54300n (CVE-2026-0629)</li>\n<li>VIGI C250 Series &lt;=2.1.0_Build_250702_Rel.54301n (CVE-2026-0629)</li>\n<li>VIGI Cx50 Series Models C350, C450 &lt;=2.1.0_Build_250702_Rel.54294n (CVE-2026-0629)</li>\n<li>VIGI Cx20I (1.0) Series Models C220I 1.0, C320I 1.0, C420I 1.0 &lt;=2.1.0_Build_251014_Rel.58331n (CVE-2026-0629)</li>\n<li>VIGI Cx20I (1.20) Series Models C220I 1.20, C320I 1.20, C420I 1.20 &lt;=2.1.0_Build_250701_Rel.44071n (CVE-2026-0629)</li>\n<li>VIGI Cx30I (1.0) Series Models C230I 1.0, C330I 1.0, C430I 1.0 &lt;=2.1.0_Build_250701_Rel.45506n (CVE-2026-0629)</li>\n<li>VIGI Cx30I (1.20) Series Models C230I 1.20, C330I 1.20, C430I 1.20 &lt;=2.1.0_Build_250701_Rel.44555n (CVE-2026-0629)</li>\n<li>VIGI Cx30 (1.0) Series Models C230 1.0, C330 1.0, C430 1.0 &lt;=2.1.0_Build_250701_Rel.46796n (CVE-2026-0629)</li>\n<li>VIGI Cx30 (1.20) Series Models C230 1.20, C330 1.20, C430 1.20 &lt;=2.1.0_Build_250701_Rel.46796n (CVE-2026-0629)</li>\n<li>VIGI Cx40I (1.0) Series Models C240I 1.0, C340I 1.0, C440I 1.0 &lt;=2.1.0_Build_250701_Rel.46003n (CVE-2026-0629)</li>\n<li>VIGI Cx40I (1.20) Series Models C240I 1.20, C340I 1.20, C440I 1.20 &lt;=2.1.0_Build_250701_Rel.45041n (CVE-2026-0629)</li>\n<li>VIGI C230I Mini Series &lt;=2.1.0_Build_250701_Rel.47570n (CVE-2026-0629)</li>\n<li>VIGI C240 1.0 Series &lt;=2.1.0_Build_250701_Rel.48425n (CVE-2026-0629)</li>\n<li>VIGI C340 2.0 Series &lt;=2.1.0_Build_250701_Rel.49304n (CVE-2026-0629)</li>\n<li>VIGI C440 2.0 Series &lt;=2.1.0_Build_250701_Rel.49778n (CVE-2026-0629)</li>\n<li>VIGI C540 2.0 Series &lt;=2.1.0_Build_250701_Rel.50397n (CVE-2026-0629)</li>\n<li>VIGI C540\u20114G Series &lt;=2.2.0_Build_250826_Rel.56808n (CVE-2026-0629)</li>\n<li>VIGI Cx40\u2011W Series Models C340\u2011W 2.0/2.20, C440\u2011W 2.0, C540\u2011W 2.0 &lt;=2.1.1_Build_250717 (CVE-2026-0629)</li>\n<li>VIGI Cx20 Series Models C320, C420 &lt;=2.1.0_Build_250701_Rel.39597n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx45 Series Models S245, S345, S445 &lt;=3.1.0_Build_250820_Rel.57668n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx55 Series Models S355, S455 &lt;=3.1.0_Build_250820_Rel.58873n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx85 Series Models S285, S385 &lt;=3.0.2_Build_250630_Rel.71279n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx45ZI Series Models S245ZI, S345ZI, S445ZI &lt;=1.2.0_Build_250820_Rel.60930n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx85PI Series Models S385PI, S485PI &lt;=1.2.0_Build_250827_Rel.66817n (CVE-2026-0629)</li>\n<li>VIGI InSight S655I Series &lt;=1.1.1_Build_250625_Rel.64224n (CVE-2026-0629)</li>\n<li>VIGI InSight S345\u20114G Series &lt;=2.1.0_Build_250725_Rel.36867n (CVE-2026-0629)</li>\n<li>VIGI InSight Sx25 Series Models S225, S325, S425 &lt;=1.1.0_Build_250630_Rel.39597n (CVE-2026-0629)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>TP-Link Systems Inc.</td>\n<td>TP-Link Systems Inc. VIGI Series IP Camera</td>\n<td>Improper Authentication</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0629</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-0629\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>TP-Link Systems Inc. VIGI Series IP Camera</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>TP-Link Systems Inc.</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>TP-Link Systems Inc. VIGI Cx45 Series Models C345, C445: &lt;=3.1.0_Build_250820_Rel.57668n, TP-Link Systems Inc. VIGI Cx55 Series Models C355, C455: &lt;=3.1.0_Build_250820_Rel.58873n, TP-Link Systems Inc. VIGI Cx85 Series Models C385, C485: &lt;=3.0.2_Build_250630_Rel.71279n, TP-Link Systems Inc. VIGI C340S Series: &lt;=3.1.0_Build_250625_Rel.65381n, TP-Link Systems Inc. VIGI C540S Series Models C540S, EasyCam C540S: &lt;=3.1.0_Build_250625_Rel.66601n, TP-Link Systems Inc. VIGI C540V Series: &lt;=2.1.0_Build_250702_Rel.54300n, TP-Link Systems Inc. VIGI C250 Series: &lt;=2.1.0_Build_250702_Rel.54301n, TP-Link Systems Inc. VIGI Cx50 Series Models C350, C450: &lt;=2.1.0_Build_250702_Rel.54294n, TP-Link Systems Inc. VIGI Cx20I (1.0) Series Models C220I 1.0, C320I 1.0, C420I 1.0: &lt;=2.1.0_Build_251014_Rel.58331n, TP-Link Systems Inc. VIGI Cx20I (1.20) Series Models C220I 1.20, C320I 1.20, C420I 1.20: &lt;=2.1.0_Build_250701_Rel.44071n, TP-Link Systems Inc. VIGI Cx30I (1.0) Series Models C230I 1.0, C330I 1.0, C430I 1.0: &lt;=2.1.0_Build_250701_Rel.45506n, TP-Link Systems Inc. VIGI Cx30I (1.20) Series Models C230I 1.20, C330I 1.20, C430I 1.20: &lt;=2.1.0_Build_250701_Rel.44555n, TP-Link Systems Inc. VIGI Cx30 (1.0) Series Models C230 1.0, C330 1.0, C430 1.0: &lt;=2.1.0_Build_250701_Rel.46796n, TP-Link Systems Inc. VIGI Cx30 (1.20) Series Models C230 1.20, C330 1.20, C430 1.20: &lt;=2.1.0_Build_250701_Rel.46796n, TP-Link Systems Inc. VIGI Cx40I (1.0) Series Models C240I 1.0, C340I 1.0, C440I 1.0: &lt;=2.1.0_Build_250701_Rel.46003n, TP-Link Systems Inc. VIGI Cx40I (1.20) Series Models C240I 1.20, C340I 1.20, C440I 1.20: &lt;=2.1.0_Build_250701_Rel.45041n, TP-Link Systems Inc. VIGI C230I Mini Series: &lt;=2.1.0_Build_250701_Rel.47570n, TP-Link Systems Inc. VIGI C240 1.0 Series: &lt;=2.1.0_Build_250701_Rel.48425n, TP-Link Systems Inc. VIGI C340 2.0 Series: &lt;=2.1.0_Build_250701_Rel.49304n, TP-Link Systems Inc. VIGI C440 2.0 Series: &lt;=2.1.0_Build_250701_Rel.49778n, TP-Link Systems Inc. VIGI C540 2.0 Series: &lt;=2.1.0_Build_250701_Rel.50397n, TP-Link Systems Inc. VIGI C540\u20114G Series: &lt;=2.2.0_Build_250826_Rel.56808n, TP-Link Systems Inc. VIGI Cx40\u2011W Series Models C340\u2011W 2.0/2.20, C440\u2011W 2.0, C540\u2011W 2.0: &lt;=2.1.1_Build_250717, TP-Link Systems Inc. VIGI Cx20 Series Models C320, C420: &lt;=2.1.0_Build_250701_Rel.39597n, TP-Link Systems Inc. VIGI InSight Sx45 Series Models S245, S345, S445: &lt;=3.1.0_Build_250820_Rel.57668n, TP-Link Systems Inc. VIGI InSight Sx55 Series Models S355, S455: &lt;=3.1.0_Build_250820_Rel.58873n, TP-Link Systems Inc. VIGI InSight Sx85 Series Models S285, S385: &lt;=3.0.2_Build_250630_Rel.71279n, TP-Link Systems Inc. VIGI InSight Sx45ZI Series Models S245ZI, S345ZI, S445ZI: &lt;=1.2.0_Build_250820_Rel.60930n, TP-Link Systems Inc. VIGI InSight Sx85PI Series Models S385PI, S485PI: &lt;=1.2.0_Build_250827_Rel.66817n, TP-Link Systems Inc. VIGI InSight S655I Series: &lt;=1.1.1_Build_250625_Rel.64224n, TP-Link Systems Inc. VIGI InSight S345\u20114G Series: &lt;=2.1.0_Build_250725_Rel.36867n, TP-Link Systems Inc. VIGI InSight Sx25 Series Models S225, S325, S425: &lt;=1.1.0_Build_250630_Rel.39597n</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>TP-Link Communications strongly recommends that users with affected devices take the following actions:</p>\n<p><strong>Mitigation</strong><br>Download and update to the latest firmware version to fix the vulnerability from the following links.</p>\n<p><strong>Mitigation</strong><br>United States users should visit the TP-Link US Download Center here: https://www.vigi.com/us/support/download/.</p>\n<p><strong>Mitigation</strong><br>Global English users should visit the TP-Link EN Download Center:https://www.vigi.com/es/support/download/.</p>\n<p><strong>Mitigation</strong><br>India users should visit the TP-Link India Download Center:https://www.vigi.com/in/support/download/.</p>\n<p><strong>Mitigation</strong><br>Please visit https://www.tp-link.com/us/support/faq/4906/ for the TP-Link advisory.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/287.html\">CWE-287 Improper Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Arko Dhar of Redinent Innovations reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-05</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-05</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-02",
        "title": "Mitsubishi Electric MELSEC iQ-R Series",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability may allow an attacker to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial-of-service condition on the affected product.</strong></p>\n<p>The following versions of Mitsubishi Electric MELSEC iQ-R Series are affected:</p>\n<ul>\n<li>MELSEC iQ-R Series R08/16/32/120PCPU firmware &lt;=48 (CVE-2025-15080)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric MELSEC iQ-R Series</td>\n<td>Improper Validation of Specified Quantity in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-15080</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An information disclosure, information tampering, and denial-of-service vulnerability exists in Mitsubishi Electric proprietary protocol communication and SLMP communication used in FA products. An attacker may be able to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial-of-service condition on the affected product by sending a specially crafted packet containing a specific command to the affected product.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-15080\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSEC iQ-R Series</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU firmware: &lt;=48</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric recommends users of the affected products follow the procedure below to update firmware version 49 or later. Download the update file for the fixed version, the engineering software for firmware upgrade, and the manual from the download website at https://www.mitsubishielectric.com/fa/download/index.html . For details on updating the firmware, see MELSEC iQ-R Module Configuration Manual \"Appendix 2 Firmware Update Function\".</p>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric recommends the following mitigations to reduce the risk of exploiting this vulnerability: Use a firewall or virtual private network (VPN) block access from untrusted networks and hosts using a firewall. Use the product within a LAN and block access from untrusted networks and hosts through a firewall. Use firewalls, IP filters, and similar controls to minimize connections to the product and prevent access from untrusted networks and hosts. For details on the IP filter function, refer to \"IP Filter\" in section 1.13, Security, of the MELSEC iQ-R Ethernet User's Manual (Application). Restrict physical access to the affected product and its connected LAN.</p>\n<p><strong>Mitigation</strong><br>For specific update instructions and additional details see the Mitsubishi Electric advisory at https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-020_en.pdf .</p>\n<p><strong>Mitigation</strong><br>For further information, contact your local Mitsubishi Electric representative at https://www.mitsubishielectric.com/fa/service-support/index.html .</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1284.html\">CWE-1284 Improper Validation of Specified Quantity in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-05</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-05</td>\n<td>1</td>\n<td>Initial Republication of Mitsubishi Electric 2025-020</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-06",
        "title": "Hitachi Energy FOX61x",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Hitachi Energy is aware of a vulnerability that affects FOX61x product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only if FOX61x devices are configured to use remote RADIUS authentication.</strong></p>\n<p>The following versions of Hitachi Energy FOX61x are affected:</p>\n<ul>\n<li>FOX61x R18, vers:FOX61x/&lt;=R17A (CVE-2024-3596, CVE-2024-3596)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9</td>\n<td>Hitachi Energy</td>\n<td>Hitachi Energy FOX61x</td>\n<td>Improper Enforcement of Message Integrity During Transmission in a Communication Channel</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-3596</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The RADIUS protocol under RFC 2865 is vulnerable to forgery attacks that allow a local attacker to modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response by exploiting a chosen-prefix collision attack on the MD5 Response Authenticator signature..</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-3596\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FOX61x</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FOX61x version R18, FOX61x version R17A and earlier</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Enable the RADIUS Message-Authenticator option in both the FOX61x and RADIUS Server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029042&amp;LanguageCode=en&amp;DocumentPartId=R18&amp;Action=launch.</p>\n<p><strong>Vendor fix</strong><br>Update to FOX61x R18, then enable the RADIUS Message-Authenticator option in both the FOX61x and RADIUS Server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029042&amp;LanguageCode=en&amp;DocumentPartId=R18&amp;Action=launch.</p>\n<p><strong>Mitigation</strong><br>If the upgrade is not possible, apply general mitigation factors with segmentation of FOX management traffic to minimize the risk.</p>\n<p><strong>Mitigation</strong><br>For more information, see the associated Hitachi Energy cybersecurity advisory 8DBD000225 Radius MD5 Vulnerability in Hitachi Energy FOX61x product at https://publisher.hitachienergy.com/preview?DocumentID=8DBD000225&amp;LanguageCode=en or https://publisher.hitachienergy.com/preview?DocumentID=8DBD000225-CSAF&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch .</p>\n<p><strong>Mitigation</strong><br>Hitachi Energy recommends implementing security practices and firewall configurations to help protect process control networks from external attacks. Such practices include ensuring that process control systems are physically protected from unauthorized access, have no direct Internet connections, and are separated from other networks by a firewall system that minimizes exposed ports, and any additional ports should be evaluated on a case-by-case basis. Process control systems should not be used for web browsing, instant messaging, or email. Portable computers and removable storage media should be thoroughly scanned for malware before being connected to a control system. Organizations should enforce proper password policies and procedures.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/924.html\">CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hitachi Energy reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Support</h2>\n<p>For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.</p>\n<hr>\n<h2>General Mitigation Factors</h2>\n<p>Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000225 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-27</td>\n<td>1</td>\n<td>Initial public release</td>\n</tr>\n<tr>\n<td>2026-02-05</td>\n<td>2</td>\n<td>Initial CISA Republication of Hitachi Energy PSIRT 8DBD000225 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-03",
        "title": "o6 Automation GmbH Open62541",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition and memory corruption.</strong></p>\n<p>The following versions of o6 Automation GmbH Open62541 are affected:</p>\n<ul>\n<li>Open62541 &gt;=1.5-rc1|&lt;1.5-rc2 (CVE-2026-1301)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.7</td>\n<td>o6 Automation GmbH</td>\n<td>o6 Automation GmbH Open62541</td>\n<td>Out-of-bounds Write</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1301</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In builds with PubSub and JSON enabled, a crafted JSON message can cause the decoder to write beyond a heap-allocated array before authentication, reliably crashing the process and corrupting memory.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1301\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>o6 Automation GmbH Open62541</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>o6 Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>o6 Automation GmbH Open62541: &gt;=1.5-rc1|&lt;1.5-rc2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>o6 Automation GmbH recommends users upgrade to the stable release of v1.5.0.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Andrew Fasano of NIST CAISI reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-05</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-05</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/02/05/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/02/05/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<div class=\"OutlineElement Ltr SCXW128239988 BCX8\">\n<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>Known Exploited Vulnerabilities (KEV) Catalog</u></a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11953\" target=\"_blank\"><u>CVE-2025-11953</u></a> React Native Community CLI OS Command Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24423\" target=\"_blank\"><u>CVE-2026-24423</u></a> SmarterTools SmarterMail Missing Authentication for Critical Function Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW128239988 BCX8\">\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\"><u>Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</u></a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\"><u>BOD 22-01 Fact Sheet</u></a> for more information.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW128239988 BCX8\">\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\"><u>specified criteria</u></a>.</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-05",
        "title": "Hitachi Energy XMC20",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Hitachi Energy is aware of a vulnerability that affects XMC20 product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only if XMC20 devices are configured to use remote RADIUS authentication.</strong></p>\n<p>The following versions of Hitachi Energy XMC20 are affected:</p>\n<ul>\n<li>XMC20 R18, vers:XMC20/&lt;=R17A (CVE-2024-3596, CVE-2024-3596)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9</td>\n<td>Hitachi Energy</td>\n<td>Hitachi Energy XMC20</td>\n<td>Improper Enforcement of Message Integrity During Transmission in a Communication Channel</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-3596</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker. An attacker can modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response using a chosen-prefix collision attack targeting the MD5 Response Authenticator signature.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-3596\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy XMC20</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>XMC20 version R18, XMC20 version R17A and earlier</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Enable the RADIUS Message-Authenticator option in both the XMC20 and RADIUS server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029001&amp;LanguageCode=en&amp;DocumentPartId=R18&amp;Action=launch.</p>\n<p><strong>Vendor fix</strong><br>Update to XMC20 R18 and then enable the RADIUS Message-Authenticator option in both the XMC20 and RADIUS server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029001&amp;LanguageCode=en&amp;DocumentPartId=R18&amp;Action=launch.</p>\n<p><strong>Mitigation</strong><br>If the upgrade is not possible, apply general mitigation factors with segmentation of FOX management traffic to minimize the risk.</p>\n<p><strong>Mitigation</strong><br>For more information, see the associated Hitachi Energy cybersecurity advisory 8DBD000233 RADIUS MD5 Vulnerability in Hitachi Energy XMC20 product available in PDF format here https://publisher.hitachienergy.com/preview?DocumentID=8DBD000233&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch or JSON format here https://publisher.hitachienergy.com/preview?DocumentID=8DBD000233-CSAF&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch.</p>\n<p><strong>Mitigation</strong><br>Hitachi Energy recommends implementing security practices and firewall configurations to help protect process control networks from external attacks. Such practices include ensuring that process control systems are physically protected from unauthorized access, have no direct Internet connections, and are separated from other networks by a firewall system that minimizes exposed ports, and any additional ports should be evaluated on a case-by-case basis. Process control systems should not be used for web browsing, instant messaging, or email. Portable computers and removable storage media should be thoroughly scanned for malware before being connected to a control system. Organizations should enforce proper password policies and procedures.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/924.html\">CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hitachi Energy reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Support</h2>\n<p>For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.</p>\n<hr>\n<h2>General Mitigation Factors</h2>\n<p>Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000233 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-27</td>\n<td>1</td>\n<td>Initial public release</td>\n</tr>\n<tr>\n<td>2026-02-05</td>\n<td>2</td>\n<td>Initial CISA Republication of Hitachi Energy PSIRT 8DBD000233 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-04",
        "title": "Ilevia EVE X1 Server",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-036-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary shell commands and the disclosure of sensitive system information.</strong></p>\n<p>The following versions of Ilevia EVE X1 Server are affected:</p>\n<ul>\n<li>EVE X1 &lt;=4.7.18.0 (CVE-2025-34185, CVE-2025-34184, CVE-2025-34183, CVE-2025-34186, CVE-2025-34187, CVE-2025-34517, CVE-2025-34518, CVE-2025-34512, CVE-2025-34513)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Ilevia</td>\n<td>Ilevia EVE X1 Server</td>\n<td>Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Insertion of Sensitive Information into Log File, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Italy</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34185</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server contains a pre-authentication file disclosure vulnerability via the 'db_log' POST parameter. Remote attackers can retrieve arbitrary files from the server, exposing sensitive system information and credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34185\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34184</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server contains an unauthenticated OS command injection vulnerability in the /ajax/php/login.php script. Remote attackers can execute arbitrary system commands by injecting payloads into the 'passwd' HTTP POST parameter, leading to full system compromise or denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34184\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34183</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server contains a vulnerability in its server-side logging mechanism that allows unauthenticated remote attackers to retrieve plaintext credentials from exposed .log files. This flaw enables full authentication bypass and system compromise through credential reuse.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34183\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/532.html\">CWE-532 Insertion of Sensitive Information into Log File</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34186</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1/X5 Server contains a vulnerability in its authentication mechanism. Unsanitized input is passed to a system() call for authentication, allowing attackers to inject special characters and manipulate command parsing. Due to the binary's interpretation of non-zero exit codes as successful authentication, remote attackers can bypass authentication and gain full access to the system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34186\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34187</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1/X5 Server contains a misconfiguration in the sudoers file that allows passwordless execution of certain Bash scripts. If these scripts are writable by web-facing users or accessible via command injection, attackers can replace them with malicious payloads. Execution with sudo grants full root access, resulting in remote privilege escalation and potential system compromise.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34187\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34517</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server firmware contains an absolute path traversal vulnerability in get_file_content.php that allows an attacker to read arbitrary files. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34517\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34518</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server firmware contains a relative path traversal vulnerability in get_file_content.php that allows an attacker to read arbitrary files. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34518\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34512</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server firmware contains a reflected cross-site scripting (XSS) vulnerability in index.php that allows an unauthenticated attacker to execute arbitrary code. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34512\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-34513</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ilevia EVE X1 Server firmware contains an OS command injection vulnerability in mbus_build_from_csv.php that allows an unauthenticated attacker to execute arbitrary code. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34513\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ilevia EVE X1 Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ilevia</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ilevia EVE X1: &lt;=4.7.18.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ilevia recommends that users perform the following mitigation steps: Update to the newest version of Ilevia Manager at https://www.ilevia.com/downloads/. Verify port 8080 is closed on all devices and routers and enable access only through the secure option provided in the updated Ilevia Manager. Change all default passwords on active systems to strong, unique credentials to prevent unauthorized access and automated attacks. Review firewall configurations to confirm that internal protections are functioning as intended and external exposure is minimized. Monitor for unauthorized access attempts and apply network segmentation where possible to reduce attack surfaces.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Gjoko Krstic of Zero Science Lab reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-05</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-05</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/reducing-attack-surface-end-support-edge-devices",
        "title": "Reducing the Attack Surface for End-of-Support Edge Devices",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/reducing-attack-surface-end-support-edge-devices",
        "summary": "<h2><strong>Introduction</strong></h2>\n<p>The Cybersecurity and Infrastructure Security Agency (CISA), the Federal Bureau of Investigation (FBI), and the U.K.\u2019s National Cyber Security Centre (NCSC) are releasing this fact sheet to urge defensive action against malicious cyber activity by nation-state threat actors. Nation-state threat actors exploit end-of-support (EOS) edge devices\u2014including, but not limited to, load balancers, firewalls, routers, and virtual private network (VPN) gateways\u2014to gain network access, maintain presence, and compromise sensitive data.</p>\n<p>Organizations using EOS devices are particularly vulnerable to compromise, especially if they are using EOS devices exposed to the public internet or external systems at the network\u2019s \u201cedge.\u201d <a href=\"https://www.cisa.gov/news-events/directives/bod-26-02-mitigating-risk-end-support-edge-devices\" data-entity-type=\"node\" data-entity-uuid=\"5277815c-d15b-4c31-aa9c-2a197136bad0\" data-entity-substitution=\"canonical\" title=\"BOD 26-02: Mitigating Risk From End-of-Support Edge Devices \">CISA\u2019s Binding Operational Directive (BOD) 26-02: Mitigating Risk From End-of-Support Edge Devices</a> requires U.S. Federal Civilian Executive Branch (FCEB) agencies to manage the lifecycle of edge devices to defend against malicious cyber activity. Although the BOD 26-02 requirement only applies to FCEB agencies, CISA, FBI, and NCSC strongly encourage organizations to follow the guidance in the BOD and this fact sheet to safeguard systems, data, and operations from nation-state threat actors.</p>\n<h2><strong>What Are EOS Edge Devices?</strong></h2>\n<p>Edge devices include technology that resides on the boundary of an organization\u2019s network and is accessible from the public internet and other external environments. An edge device becomes an \u201cend-of-support\u201d or \u201cunsupported\u201d device when its manufacturer no longer:</p>\n<ul>\n<li>Monitors it for defects in its software and/or firmware, and</li>\n<li>Updates it with patches for common vulnerabilities and exposures (CVEs), security updates, and software fixes (hotfixes).</li>\n</ul>\n<p>EOS edge devices pose significant risks for organizations because threat actors can exploit unresolved security gaps. Nation-state threat actors can exploit these devices as entry points to access modern, supported environments, placing organizations\u2019 data, services, and overall security at serious risk. EOS devices may also cause compatibility issues that disrupt productivity.</p>\n<h2><strong>Mitigations</strong></h2>\n<p>Organizations should be prepared to respond to malicious cyber activity. As the nation\u2019s cyber defense agency, CISA and its partners stand ready to help prepare organizations to respond to and mitigate the impact of malicious cyber activity. CISA and its partners strongly urge all organizations to review <a href=\"https://www.cisa.gov/news-events/directives/bod-26-02-mitigating-risk-end-support-edge-devices\" data-entity-type=\"node\" data-entity-uuid=\"5277815c-d15b-4c31-aa9c-2a197136bad0\" data-entity-substitution=\"canonical\" title=\"BOD 26-02: Mitigating Risk From End-of-Support Edge Devices \">BOD 26-02</a> and implement the following mitigations.</p>\n<h3><strong>Maintain Asset Inventory and Audits</strong></h3>\n<p>Keeping track of all devices within a network will equip network defenders with the awareness necessary to protect vulnerable assets.</p>\n<ul>\n<li>Actively scan networks for undocumented and outdated edge devices.</li>\n<li>Maintain an inventory of all edge devices and their respective support timelines.</li>\n<li>Regularly review inventory and EOS dates.\n<ul>\n<li>Critical infrastructure owners and operators, see <a href=\"https://www.cisa.gov/resources-tools/resources/foundations-ot-cybersecurity-asset-inventory-guidance-owners-and-operators\" data-entity-type=\"node\" data-entity-uuid=\"3984818e-d858-4c63-8885-20c174d56f28\" data-entity-substitution=\"canonical\" title=\"Foundations for OT Cybersecurity: Asset Inventory Guidance for Owners and Operators\">Foundations for OT Cybersecurity: Asset Inventory Guidance for Owners and Operators</a>.</li>\n</ul>\n</li>\n</ul>\n<h3><strong>Replace EOS Edge Devices and Software</strong></h3>\n<p>Network defenders should proactively monitor for and replace unsupported edge devices to reduce a network perimeter\u2019s vulnerability.</p>\n<ul>\n<li>Take prompt action to replace EOS edge devices; as these devices age, managing their risks becomes increasingly challenging and costly.</li>\n</ul>\n<h3><strong>Install Updates and Patch Known CVEs</strong></h3>\n<p>Software updates will patch known CVEs; if automatic updates are not enabled, network defenders should proactively monitor for these updates.</p>\n<ul>\n<li>Ensure EOS devices operate on the latest supported software version when immediate replacement is not possible. By using the latest software update, organizations can address CVEs and other known vulnerabilities identified up to the time of the update.</li>\n<li>Enable automatic updates on all devices to install timely patches.</li>\n</ul>\n<h2><strong>Resources</strong></h2>\n<p>The following resources provide further guidance on protecting systems from cyber threats linked to EOS software or devices:</p>\n<ul>\n<li>CISA: <a href=\"https://www.cisa.gov/topics/cybersecurity-best-practices/edge-device-security\" data-entity-type=\"node\" data-entity-uuid=\"665a3e35-4340-49d6-9c65-67dd9a39dd62\" data-entity-substitution=\"canonical\" title=\"Edge Device Security\">Edge Device Security</a> webpage provides edge device best practices to help organizations secure their network perimeters against modern cyber threats.</li>\n<li>CISA: <a href=\"https://www.cisa.gov/resources-tools/resources/guidance-and-strategies-protect-network-edge-devices\" data-entity-type=\"node\" data-entity-uuid=\"5e2f547f-3188-4ff4-8791-808a5f04f28f\" data-entity-substitution=\"canonical\" title=\"Guidance and Strategies to Protect Network Edge Devices\">Guidance and Strategies to Protect Network Edge Devices</a> offers practical advice and recommendations for protecting edge devices, focusing on minimizing vulnerabilities and improving network resilience.</li>\n<li>CISA: <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities Catalog</a> provides a regularly updated list of vulnerabilities actively exploited by threat actors, allowing organizations to prioritize remediation efforts effectively.</li>\n<li>ASD\u2019s ACSC: <a href=\"https://www.cyber.gov.au/business-government/protecting-devices-systems/legacy-it-management/managing-the-risks-of-legacy-it-executive-guidance\" target=\"_blank\">Managing the risks of legacy IT: Executive guidance</a> provides strategies and high-level guidance for executives to mitigate risks stemming from outdated and legacy IT systems.</li>\n<li>ASD\u2019s ACSC: <a href=\"https://media.defense.gov/2025/Feb/03/2003636716/-1/-1/0/CSI_MITIGATION-STRATEGIES-FOR-EDGE-DEVICES-PRACTITIONER-GUIDANCE.PDF\" target=\"_blank\">Mitigation strategies for edge devices: Practitioner guidance</a> offers detailed technical advice and actionable steps for IT practitioners to enhance the security of edge devices in their networks.</li>\n<li>CISA: <a href=\"https://www.cisa.gov/free-cybersecurity-services-and-tools\">No-Cost Cybersecurity Services and Tools</a> lists no-cost services and tools provided by CISA, as well as private and public sector organizations across the cyber community, to strengthen security postures and address cyber risks.</li>\n<li>CISA: <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa20-245a\" data-entity-type=\"node\" data-entity-uuid=\"6a19e531-60dd-4c14-9232-240b001d67c8\" data-entity-substitution=\"canonical\" title=\"Technical Approaches to Uncovering and Remediating Malicious Activity\">Technical Approaches to Uncovering and Remediating Malicious Activity</a> presents detailed technical methodologies and best practices for detecting, analyzing, and addressing malicious activity within networks.</li>\n<li>OASIS: <a href=\"https://openeox.org/\" target=\"_blank\">OpenEoX</a> provides robust guidance on the secure lifecycle management and handling of EOS software and associated tools to reduce security vulnerabilities.</li>\n<li>NCSC: <a href=\"https://www.ncsc.gov.uk/guidance/guidance-on-digital-forensics-protective-monitoring\" target=\"_blank\">Guidance on digital forensics and protective monitoring specifications for producers of network devices and appliances</a> delivers best practices and recommendations for conducting digital forensic investigations and implementing protective monitoring to safeguard network devices against cyber threats.&nbsp;</li>\n</ul>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/reducing-attack-surface-end-support-edge-devices\">CISA PRODUCT SURVEY</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Thu, 05 Feb 26 12:00:00 +0000",
        "last_updated": "Thu, 05 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-04",
        "title": "Synectix LAN 232 TRIO",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-034-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in an unauthenticated attacker modifying critical device settings or factory resetting the device.</strong></p>\n<p>The following versions of Synectix LAN 232 TRIO are affected:</p>\n<ul>\n<li>LAN 232 TRIO vers:all/* (CVE-2026-1633)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>Synectix</td>\n<td>Synectix LAN 232 TRIO</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Emergency Services, Energy, Information Technology, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1633</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Synectix LAN 232 TRIO 3-Port serial to ethernet adapter exposes its web management interface without requiring authentication, allowing unauthenticated users to modify critical device settings or factory reset the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1633\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Synectix LAN 232 TRIO</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Synectix</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Synectix LAN 232 TRIO: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The affected products should be considered end-of-life, as Synectix is no longer in business and therefore firmware fixes, mitigations and updates will be unavailable.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Souvik Kandar of MicroSec (microsec.io) reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-03</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 03 Feb 26 12:00:00 +0000",
        "last_updated": "Tue, 03 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-03",
        "title": "RISS SRL MOMA Seismic Station",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-034-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in an unauthenticated attacker creating a denial-of-service condition.</strong></p>\n<p>The following versions of RISS SRL MOMA Seismic Station are affected:</p>\n<ul>\n<li>MOMA Seismic Station &lt;=v2.4.2520 (CVE-2026-1632)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>RISS SRL</td>\n<td>RISS SRL MOMA Seismic Station</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Dams, Energy, Water and Wastewater, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Italy</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1632</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MOMA Seismic Station Version v2.4.2520 and prior exposes its web management interface without requiring authentication, which could allow an unauthenticated attacker to modify configuration settings, acquire device data or remotely reset the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1632\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>RISS SRL MOMA Seismic Station</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>RISS SRL</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RISS SRL MOMA Seismic Station: &lt;=v2.4.2520</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>RISS SRL did not respond to CISA's request for coordination. Users of RISS MOMA Seismic Station are encouraged to contact RISS SRL (info@riss-srl.com) for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Souvik Kandar reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-03</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 03 Feb 26 12:00:00 +0000",
        "last_updated": "Tue, 03 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-01",
        "title": "Mitsubishi Electric FREQSHIP-mini for Windows",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-034-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to, modify, delete, or destroy information stored on the system where the affected product is installed, or cause a denial-of-service condition on the affected system.</strong></p>\n<p>The following versions of Mitsubishi Electric FREQSHIP-mini for Windows are affected:</p>\n<ul>\n<li>FREQSHIP-mini for Windows &gt;=8.0.0|&lt;=8.0.2 (CVE-2025-10314)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric FREQSHIP-mini for Windows</td>\n<td>Incorrect Default Permissions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Information Technology, Healthcare and Public Health, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Japan</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-10314</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A malicious code execution vulnerability exists in Mitsubishi's small-capacity UPS shutdown software, FREQSHIP-mini for Windows, due to incorrect default permissions. A local attacker may be able to execute arbitrary code with system privileges by replacing service executable or DLL files in the installation directory with specially crafted files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-10314\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric FREQSHIP-mini for Windows</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric FREQSHIP-mini for Windows: &gt;=8.0.0|&lt;=8.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The vulnerability has been addressed in FREQSHIP-mini for Windows version 8.1.0 or later. Download and install the updated version from the Mitsubishi Electric download site at https://www.mitsubishielectric.co.jp/fa/download/index.html .</p>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of this vulnerability being exploited: Use the PCs with the affected product installed only within a LAN, and block remote logins from untrusted networks, hosts, and non-administrator users. Block unauthorized access by using a firewall or virtual private network (VPN), etc., and allow remote login only for administrators when connecting the PCs with the affected product installed to the internet. Restrict physical access to the PC and its connected network to prevent unauthorized access. Do not click on links or open attachments in emails from untrusted sources. Install and regularly update antivirus software.</p>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric Corporation recommends users contact their local Mitsubishi Electric representative at https://www.mitsubishielectric.co.jp/fa/support/purchase/index.html with questions.</p>\n<p><strong>Mitigation</strong><br>For additional details, refer to Mitsubishi Electric's security advisory at https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2025-019_en.pdf .</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Kazuma Matsumoto of GMO Cybersecurity by IERAE, Inc. reported this vulnerability to Mitsubishi Electric</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-03</td>\n<td>1</td>\n<td>Initial Republication of Mitsubishi Electric 2025-019.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 03 Feb 26 12:00:00 +0000",
        "last_updated": "Tue, 03 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-02",
        "title": "Avation Light Engine Pro",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-034-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to take full control of the device.</strong></p>\n<p>The following versions of Avation Light Engine Pro are affected:</p>\n<ul>\n<li>Light Engine Pro vers:all/* (CVE-2026-1341)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Avation</td>\n<td>Avation Light Engine Pro</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Australia</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1341</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Avation Light Engine Pro exposes its configuration and control interface without any authentication or access control.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1341\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Avation Light Engine Pro</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Avation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Avation Light Engine Pro: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Avation has not responded to CISA's request to coordinate. Users of Avation Light Engine Pro are encouraged to contact Avation for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Souvik Kandar reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-03</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 03 Feb 26 12:00:00 +0000",
        "last_updated": "Tue, 03 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/02/03/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Four Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/02/03/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added&nbsp;four&nbsp;new&nbsp;vulnerabilities&nbsp;to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-19006\" target=\"_blank\">CVE-2019-19006</a>&nbsp;Sangoma&nbsp;FreePBX&nbsp;Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-39935\" target=\"_blank\">CVE-2021-39935</a>&nbsp;GitLab Community and Enterprise Editions Server-Side Request Forgery (SSRF) Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40551\" target=\"_blank\">CVE-2025-40551</a>&nbsp;SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-64328\" target=\"_blank\">CVE-2025-64328</a>&nbsp;Sangoma&nbsp;FreePBX&nbsp;OS Command Injection Vulnerability&nbsp;</li>\n</ul>\n<p>These&nbsp;types&nbsp;of&nbsp;vulnerabilities&nbsp;are&nbsp;frequent attack&nbsp;vectors&nbsp;for malicious cyber actors and&nbsp;pose&nbsp;significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate&nbsp;identified&nbsp;vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a>&nbsp;for more information.&nbsp;</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing&nbsp;timely&nbsp;remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>&nbsp;as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 03 Feb 26 12:00:00 +0000",
        "last_updated": "Tue, 03 Feb 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1281\" target=\"_blank\">CVE-2026-1281</a> Ivanti Endpoint Manager Mobile (EPMM) Code Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 29 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 29 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-02",
        "title": "Rockwell Automation ArmorStart LT",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-029-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition.</strong></p>\n<p>The following versions of Rockwell Automation ArmorStart LT are affected:</p>\n<ul>\n<li>ArmorStart LT 290D &lt;=V2.002 (CVE-2025-9464, CVE-2025-9465, CVE-2025-9466, CVE-2025-9278, CVE-2025-9279, CVE-2025-9280, CVE-2025-9281, CVE-2025-9282, CVE-2025-9283)</li>\n<li>ArmorStart LT 291D &lt;=V2.002 (CVE-2025-9464, CVE-2025-9465, CVE-2025-9466, CVE-2025-9278, CVE-2025-9279, CVE-2025-9280, CVE-2025-9281, CVE-2025-9282, CVE-2025-9283)</li>\n<li>ArmorStart LT 294D &lt;=V2.002 (CVE-2025-9464, CVE-2025-9465, CVE-2025-9466, CVE-2025-9278, CVE-2025-9279, CVE-2025-9280, CVE-2025-9281, CVE-2025-9282, CVE-2025-9283)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation ArmorStart LT</td>\n<td>Uncontrolled Resource Consumption</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9464</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. This vulnerability is triggered during fuzzing of multiple CIP classes, which causes the CIP port to become unresponsive.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9464\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9465</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9465\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9466</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9466\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9278</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. After running a Burp Suite active scan, the device loses ICMP connectivity, causing the web application to become inaccessible.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9278\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9279</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limit Storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9279\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9280</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. Fuzzing performed using Defensics causes the device to become unresponsive, requiring a reboot.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9280\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9281</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive step limit storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9281\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9282</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive limited storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9282\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9283</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ArmorStart\u00ae LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limits Storms tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-9283\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT 290D: &lt;=V2.002, Rockwell Automation ArmorStart LT 291D: &lt;=V2.002, Rockwell Automation ArmorStart LT 294D: &lt;=V2.002</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>There is no patch or upgrade at this time. Rockwell Automation recommends users apply security best practices to mitigate the risk of these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1768 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilties to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-29</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-29</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation advisory SD1768</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 29 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 29 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-03",
        "title": "Rockwell Automation ControlLogix",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-029-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.</strong></p>\n<p>The following versions of Rockwell Automation ControlLogix are affected:</p>\n<ul>\n<li>ControlLogix Redundancy Enhanced Module Catalog 1756-RM2 Firmware vers:all/* (CVE-2025-14027)</li>\n<li>ControlLogix Redundancy Enhanced Module Catalog 1756-RM2XT Firmware vers:all/* (CVE-2025-14027)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation ControlLogix</td>\n<td>Missing Release of Memory after Effective Lifetime</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Energy, Critical Manufacturing, Food and Agriculture, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14027</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple denial-of-service issues exist in 1756-RM2 and 1756-RM2XT firmware (ControlLogix Redundancy Enhanced Modules). These issues can be triggered through various crafted inputs, including malformed Class 3 messages, memory leak conditions, and other resource exhaustion scenarios. Exploitation may cause the device to become unresponsive and, in some cases, result in a major nonrecoverable fault. Recovery may require a restart.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14027\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ControlLogix</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ControlLogix Redundancy Enhanced Module Catalog 1756-RM2 Firmware: vers:all/*, Rockwell Automation ControlLogix Redundancy Enhanced Module Catalog 1756-RM2XT Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends that users upgrade from the 1756-RM2 to 1756-RM3.</p>\n<p><strong>Mitigation</strong><br>If users are unable to upgrade to the 1756-RM3, security best practices should be applied.</p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1769 advisory for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-29</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-29</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation advisory SD1769</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 29 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 29 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-01",
        "title": "KiloView Encoder Series (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-029-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-029-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated attacker to create or delete administrator accounts, granting full administrative control.</strong></p>\n<p>The following versions of KiloView Encoder Series are affected:</p>\n<ul>\n<li>Encoder Series E1 hardware Version 1.4 4.7.2516 (CVE-2026-1453)</li>\n<li>Encoder Series E1 hardware Version 1.6.20 4.7.2511|4.8.2523|4.8.2611|4.6.2400|4.7.2512|4.8.2561|4.8.2554|4.3.2029|4.8.2555|4.6.2408 (CVE-2026-1453)</li>\n<li>Encoder Series E1-s hardware Version 1.4 4.7.2516|4.8.2519|4.8.2525|4.8.2611|4.8.2561|4.8.2554|4.8.2523 (CVE-2026-1453)</li>\n<li>Encoder Series E2 hardware Version 1.7.20 4.8.2611|4.8.2561 (CVE-2026-1453)</li>\n<li>Encoder Series E2 hardware Version 1.8.20 4.8.2523|4.8.2611|4.8.2554 (CVE-2026-1453)</li>\n<li>Encoder Series G1 hardware Version 1.6.20 4.8.2561 (CVE-2026-1453)</li>\n<li>Encoder Series P1 hardware Version 1.3.20 4.8.2633|4.8.2608 (CVE-2026-1453)</li>\n<li>Encoder Series P2 hardware Version 1.8.20 4.8.2633 (CVE-2026-1453)</li>\n<li>Encoder Series RE1 hardware Version 2.0.00 4.7.2513 (CVE-2026-1453)</li>\n<li>Encoder Series RE1 hardware Version 3.0.00 4.8.2519|4.8.2561|4.8.2611|4.8.2525 (CVE-2026-1453)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>KiloView</td>\n<td>KiloView Encoder Series</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1453</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A missing authentication for critical function vulnerability in KiloView Encoder Series could allow an unauthenticated attacker to create or delete administrator accounts. This vulnerability can grant the attacker full administrative control over the product.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1453\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>KiloView Encoder Series</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>KiloView</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>KiloView Encoder Series E1 hardware Version 1.4: 4.7.2516, KiloView Encoder Series E1 hardware Version 1.6.20: 4.7.2511|4.8.2523|4.8.2611|4.6.2400|4.7.2512|4.8.2561|4.8.2554|4.3.2029|4.8.2555|4.6.2408, KiloView Encoder Series E1-s hardware Version 1.4: 4.7.2516|4.8.2519|4.8.2525|4.8.2611|4.8.2561|4.8.2554|4.8.2523, KiloView Encoder Series E2 hardware Version 1.7.20: 4.8.2611|4.8.2561, KiloView Encoder Series E2 hardware Version 1.8.20: 4.8.2523|4.8.2611|4.8.2554, KiloView Encoder Series G1 hardware Version 1.6.20: 4.8.2561, KiloView Encoder Series P1 hardware Version 1.3.20: 4.8.2633|4.8.2608, KiloView Encoder Series P2 hardware Version 1.8.20: 4.8.2633, KiloView Encoder Series RE1 hardware Version 2.0.00: 4.7.2513, KiloView Encoder Series RE1 hardware Version 3.0.00: 4.8.2519|4.8.2561|4.8.2611|4.8.2525</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>KiloView states that these specific hardware versions are end-of-life; therefore, no patches will be released due to hardware limitations. KiloView recommends that users implement mitigation measures such as network isolation or upgrade to newer hardware generations.</p>\n<p><strong>Mitigation</strong><br>Users of affected versions of KiloView Encoder Series are invited to contact KiloView customer support at https://www.kiloview.com/contact/ for additional information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Muhammad Ammar (0xam225) reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-29</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-29</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-02-05</td>\n<td>2</td>\n<td>Update A - Affected products are end-of-life</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 29 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 29 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/28/fortinet-releases-guidance-address-ongoing-exploitation-authentication-bypass-vulnerability-cve-2026",
        "title": "Fortinet Releases Guidance to Address Ongoing Exploitation of Authentication Bypass Vulnerability CVE-2026-24858",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/28/fortinet-releases-guidance-address-ongoing-exploitation-authentication-bypass-vulnerability-cve-2026",
        "summary": "<p>Newly disclosed vulnerability <a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24858\" target=\"_blank\">Common Vulnerabilities and Exposures (CVE)-2026-24858</a> [<a href=\"https://cwe.mitre.org/data/definitions/288.html\" target=\"_blank\" title=\"CWE-288: Authentication Bypass Using an Alternate Path or Channel\">Common Weakness Enumeration (CWE)-288: Authentication Bypass Using an Alternate Path or Channel</a>] allows malicious actors with a FortiCloud account and a registered device to log in to separate devices registered to other users in FortiOS, FortiManager, FortiWeb, FortiProxy, and FortiAnalyzer, if FortiCloud single sign on (SSO) is enabled on devices.<a href=\"#Note1\"><sup>1</sup></a></p>\n<p>Users are vulnerable to <a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24858\" target=\"_blank\">CVE-2026-24858</a> even if they updated Fortinet devices to address previously disclosed FortiCloud SSO bypass vulnerabilities <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59718\" target=\"_blank\" title=\"CVE-2025-59718\">CVE-2025-59718</a> and <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59719\" target=\"_blank\" title=\"CVE-2025-59719\">CVE-2025-59719</a> [<a href=\"https://cwe.mitre.org/data/definitions/347.html\" target=\"_blank\" title=\"CWE-347: Improper Verification of Cryptographic Signature\">CWE-347: Improper Verification of Cryptographic Signature</a>].<a href=\"#Note2\"><sup>2</sup></a> <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59718\" target=\"_blank\" title=\"CVE-2025-59718\">CVE-2025-59718</a> and <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59719\" target=\"_blank\" title=\"CVE-2025-59719\">CVE-2025-59719</a> affect FortiOS, FortiWeb, FortiProxy, and FortiSwitch Manager, and allow malicious actors to bypass the SSO login authentication via a crafted Security Assertion Markup Language (SAML) message.<a href=\"#Note3\"><sup>3&nbsp;</sup></a> On Fortinet devices that had been fully upgraded to the latest release addressing <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59718\" target=\"_blank\" title=\"CVE-2025-59718\">CVE-2025-59718</a> and <a href=\"https://www.cve.org/CVERecord?id=CVE-2025-59719\" target=\"_blank\" title=\"CVE-2025-59719\">CVE-2025-59719</a> at the time of <a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24858\" target=\"_blank\">CVE-2026-24858</a> exploitation, Fortinet observed the following malicious activity:</p>\n<ul>\n<li>Unauthorized firewall configuration changes on FortiGate devices.</li>\n<li>Unauthorized creation of accounts.</li>\n<li>Unauthorized configuration changes of virtual private networks (VPNs) to grant access to new accounts.<a href=\"#Note4\"><sup>4</sup></a><sup>&nbsp;</sup></li>\n</ul>\n<p>According to Fortinet, on Jan. 26, 2026, Fortinet disabled all FortiCloud SSO authentication to mitigate <a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24858\" target=\"_blank\">CVE-2026-24858</a>, then reinstated the service on Jan. 27, 2026, with changes to prevent exploitation of vulnerable devices. &nbsp;</p>\n<p>CISA added CVE-2026-24858 to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" title=\"Known Exploited Vulnerabilities (KEV) Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a> on Jan. 27, 2026.</p>\n<p>CISA urges users to check for indicators of compromise on all internet-accessible Fortinet products affected by this vulnerability and immediately apply updates as soon as they are available using Fortinet\u2019s instructions:</p>\n<ul>\n<li><a href=\"https://fortiguard.fortinet.com/psirt/FG-IR-26-060\" target=\"_blank\" title=\"Administrative FortiCloud SSO authentication bypass\">Administrative FortiCloud SSO authentication bypass</a></li>\n<li><a href=\"https://www.fortinet.com/blog/psirt-blogs/analysis-of-sso-abuse-on-fortios\" target=\"_blank\" title=\"Analysis of Single Sign-On Abuse on FortiOS\">Analysis of Single Sign-On Abuse on FortiOS</a></li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.\u202f</p>\n<h2><strong>Notes</strong></h2>\n<ol>\n<li><a class=\"ck-anchor\" id=\"Note1\"></a>Fortinet, \u201cAdministrative FortiCloud SSO Authentication Bypass,\u201d <em>FortiGuard Labs,&nbsp;</em>last modified January 27, 2026, <a href=\"https://fortiguard.fortinet.com/psirt/FG-IR-26-060\" target=\"_blank\">https://fortiguard.fortinet.com/psirt/FG-IR-26-060</a>.</li>\n<li><a class=\"ck-anchor\" id=\"Note2\"></a>Fortinet, \u201cMultiple Fortinet Products\u2019 FortiCloud SSO Login Authentication Bypass,\u201d <em>FortiGuard Labs,&nbsp;</em>last modified<em>&nbsp;</em>December 9, 2025, <a href=\"https://fortiguard.fortinet.com/psirt/FG-IR-25-647\" target=\"_blank\" title=\"https://fortiguard.fortinet.com/psirt/FG-IR-25-647\">https://fortiguard.fortinet.com/psirt/FG-IR-25-647</a>.</li>\n<li><a class=\"ck-anchor\" id=\"Note3\"></a>Carl Windsor, \u201cAnalysis of Single Sign-On Abuse on FortiOS,\u201d <em>PSIRT Blogs&nbsp;</em>(blog), <em>Fortinet</em>, last modified January 22, 2026, <a href=\"https://www.fortinet.com/blog/psirt-blogs/analysis-of-sso-abuse-on-fortios\" target=\"_blank\" title=\"https://www.fortinet.com/blog/psirt-blogs/analysis-of-sso-abuse-on-fortios\">https://www.fortinet.com/blog/psirt-blogs/analysis-of-sso-abuse-on-fortios</a>.</li>\n<li><a class=\"ck-anchor\" id=\"Note4\"></a>Arctic Wolf Labs, \u201cArctic Wolf Observes Malicious Configuration Changes on Fortinet FortiGate Devices via SSO Accounts,\u201d <em>Arctic Wolf Blog&nbsp;</em>(blog), <em>Arctic Wolf,&nbsp;</em>last modified January 21, 2026<em>,&nbsp;</em><a href=\"https://arcticwolf.com/resources/blog/arctic-wolf-observes-malicious-configuration-changes-fortinet-fortigate-devices-via-sso-accounts/\" target=\"_blank\" title=\"https://arcticwolf.com/resources/blog/arctic-wolf-observes-malicious-configuration-changes-fortinet-fortigate-devices-via-sso-accounts/\">https://arcticwolf.com/resources/blog/arctic-wolf-observes-malicious-configuration-changes-fortinet-fortigate-devices-via-sso-accounts/</a>.</li>\n</ol>",
        "summary_is_html": true,
        "first_seen": "Wed, 28 Jan 26 12:00:00 +0000",
        "last_updated": "Wed, 28 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-01",
        "title": "iba Systems ibaPDA",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-027-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to perform unauthorized actions on the file system.</strong></p>\n<p>The following versions of iba Systems ibaPDA are affected:</p>\n<ul>\n<li>ibaPDA (CVE-2025-14988)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>iba Systems</td>\n<td>iba Systems ibaPDA</td>\n<td>Incorrect Permission Assignment for Critical Resource</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14988</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue has been identified in ibaPDA that could allow unauthorized actions on the file system under certain conditions. This may impact the confidentiality, integrity, or availability of the system.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-14988\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>iba Systems ibaPDA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>iba Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>iba Systems ibaPDA: 8.12.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>iba Systems recommends users update to ibaPDA v8.12.1 or a later version.</p>\n<p><strong>Mitigation</strong><br>If Installing the update is not possible, iba Systems recommends users:</p>\n<p><strong>Mitigation</strong><br>Enable User Management:To activate user management, navigate to User Management settings under the Configure option. Set a password for the admin user to enable user management.</p>\n<p><strong>Vendor fix</strong><br>Configure Server Access:To configure, open Server Access Manager (found under Configure in the ibaPDA Client). Set the configuration to restrict access. For example, only 127.0.0.1 (localhost) or specific system IP addresses to communicate with ibaPDA can connect to the ibaPDA Server. (In this example, only connections from localhost are permitted to access ibaPDA.)</p>\n<p><strong>Vendor fix</strong><br>Restrict Connections to Localhost (if ibaPDA is only accessed from the system where it runs):</p>\n<p><strong>Vendor fix</strong><br>Go to I/O Manager, then General, and deactivate the option \"Automatically open necessary ports in Windows Firewall.\" (If this option remains active, after a restart of ibaPDA or a restart for data acquisition, the firewall will be reconfigured automatically.)</p>\n<p><strong>Vendor fix</strong><br>Then, go to Advanced Windows Firewall settings and delete or deactivate all incoming rules for the ibaPDA Client and Server.</p>\n<p><strong>Vendor fix</strong><br>Manually create firewall rules for the connection used for ibaPDA and verify that the correct ports are configured. For assistance with identifying the ports used by the ibaPDA service can be found in the iba Help Center.</p>\n<p><strong>Vendor fix</strong><br>Note: After making the changes, verify that all ibaPDA services are operating as expected and that the data acquisition is functioning correctly.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/732.html\">CWE-732 Incorrect Permission Assignment for Critical Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-27</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 27 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 27 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-04",
        "title": "Johnson Controls Metasys Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-027-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in remote SQL execution, leading to alteration or loss of data.</strong></p>\n<p>The following versions of Johnson Controls Metasys Products are affected:</p>\n<ul>\n<li>Metasys Application and Data Server (ADS) (CVE-2025-26385)</li>\n<li>Metasys Extended Application and Data Server (ADX) (CVE-2025-26385)</li>\n<li>Metasys LCS8500 (CVE-2025-26385)</li>\n<li>Metasys NAE8500 (CVE-2025-26385)</li>\n<li>Metasys System Configuration Tool (SCT) (CVE-2025-26385)</li>\n<li>Metasys Controller Configuration Tool (CCT) (CVE-2025-26385)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>Johnson Controls</td>\n<td>Johnson Controls Metasys Products</td>\n<td>Improper Neutralization of Special Elements used in a Command ('Command Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Government Services and Facilities, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Ireland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-26385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Under certain circumstances a successful exploitation of this vulnerability could allow remote SQL execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-26385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Johnson Controls Metasys Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Johnson Controls</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Johnson Controls Metasys Application and Data Server (ADS): &lt;=14.1, Johnson Controls Metasys Extended Application and Data Server (ADX):14.1, Johnson Controls Metasys LCS8500: &gt;=12.0|&lt;=14.1, Johnson Controls Metasys NAE8500: &gt;=12.0|&lt;=14.1, Johnson Controls Metasys System Configuration Tool (SCT): &lt;=17.1, Johnson Controls Metasys Controller Configuration Tool (CCT): &lt;=17.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Johnson Controls recommends downloading and executing the Metasys patch for GIV-165989 from the License Portal. Login credentials are required.</p>\n<p><strong>Mitigation</strong><br>Johnson Controls advises following the Metasys Release 14 Hardening Guide to ensure each Metasys installation is on a segmented network and not exposed to untrusted networks such as the internet.</p>\n<p><strong>Mitigation</strong><br>Additionally, closing incoming TCP port 1433 can protect against exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more detailed mitigation instructions, visit Johnson Controls Product Security Advisory JCI-PSA-2026-02.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/77.html\">CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Johnson Controls reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-27</td>\n<td>1</td>\n<td>Initial Republication of Johnson Controls advisory JCI-PSA-2026-02</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 27 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 27 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02",
        "title": "Festo Didactic SE MES PC",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-027-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>MES PCs shipped with Windows 10 come pre-installed with XAMPP. XAMPP is a bundle of third-party open-source applications including the Apache HTTP Server, the MariaDB database and more. From time to time, vulnerabilities in these applications are discovered. These are fixed in newer versions of XAMPP by updating the bundled applications. MES PCs shipped with Windows 10 include a copy of XAMPP which contains around 140 such vulnerabilities listed in this advisory. They can be fixed by replacing XAMPP with Festo Didactic's Factory Control Panel application.</strong></p>\n<p>The following versions of Festo Didactic SE MES PC are affected:</p>\n<ul>\n<li>MES PC (CVE-2019-11036, CVE-2023-25727, CVE-2021-2011, CVE-2022-32083, CVE-2021-46668, CVE-2018-19518, CVE-2021-2194, CVE-2019-11049, CVE-2022-31626, CVE-2022-32084, CVE-2022-32088, CVE-2022-27377, CVE-2020-2922, CVE-2019-9638, CVE-2019-11044, CVE-2020-7068, CVE-2020-7069, CVE-2015-2301, CVE-2023-0568, CVE-2022-27458, CVE-2021-21706, CVE-2022-27452, CVE-2020-7071, CVE-2022-27387, CVE-2022-27376, CVE-2019-11043, CVE-2021-2032, CVE-2021-2007, CVE-2019-11045, CVE-2022-27445, CVE-2022-27457, CVE-2022-27384, CVE-2022-23808, CVE-2023-0567, CVE-2019-9025, CVE-2022-27379, CVE-2019-9637, CVE-2021-27928, CVE-2021-21703, CVE-2020-2760, CVE-2021-2166, CVE-2015-2787, CVE-2022-23807, CVE-2020-2752, CVE-2021-46666, CVE-2020-2814, CVE-2020-7065, CVE-2021-21705, CVE-2020-7062, CVE-2019-11039, CVE-2019-11035, CVE-2022-27447, CVE-2019-11046, CVE-2022-27446, CVE-2022-27386, CVE-2019-9639, CVE-2019-11042, CVE-2022-27385, CVE-2020-7059, CVE-2020-7070, CVE-2022-32091, CVE-2015-2348, CVE-2019-9020, CVE-2021-35604, CVE-2022-27444, CVE-2018-14883, CVE-2014-9705, CVE-2020-7064, CVE-2022-27382, CVE-2020-7063, CVE-2021-2372, CVE-2019-9021, CVE-2018-14851, CVE-2022-27448, CVE-2021-46663, CVE-2021-2180, CVE-2014-9709, CVE-2023-25690, CVE-2022-32082, CVE-2022-31629, CVE-2019-9022, CVE-2016-3078, CVE-2023-0662, CVE-2021-2022, CVE-2022-32089, CVE-2019-11048, CVE-2021-46669, CVE-2019-11047, CVE-2022-27383, CVE-2021-46667, CVE-2022-32087, CVE-2022-36760, CVE-2020-7060, CVE-2018-17082, CVE-2019-9640, CVE-2021-46661, CVE-2019-11034, CVE-2022-27456, CVE-2020-7061, CVE-2022-27455, CVE-2021-2144, CVE-2021-2154, CVE-2022-21595, CVE-2019-11040, CVE-2021-2389, CVE-2023-27522, CVE-2020-2812, CVE-2021-46665, CVE-2022-32086, CVE-2022-32085, CVE-2021-21704, CVE-2020-7066, CVE-2022-31628, CVE-2021-46662, CVE-2016-5385, CVE-2022-37436, CVE-2013-6501, CVE-2021-21702, CVE-2019-9024, CVE-2019-9023, CVE-2022-27449, CVE-2021-46664, CVE-2019-11050, CVE-2021-21708, CVE-2022-31625, CVE-2022-32081, CVE-2022-27378, CVE-2006-20001, CVE-2018-19935, CVE-2022-4900, CVE-2018-12882, CVE-2019-9641, CVE-2022-27380, CVE-2022-27381, CVE-2021-21707, CVE-2022-27451, CVE-2020-2780, CVE-2019-11041, CVE-2021-2174)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Festo Didactic SE</td>\n<td>Festo Didactic SE MES PC</td>\n<td>Buffer Over-read, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Input Validation, Improper Handling of Values, Uncontrolled Resource Consumption, Improper Neutralization of Argument Delimiters in a Command ('Argument Injection'), Double Free, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Use After Free, Exposure of Sensitive Information to an Unauthorized Actor, Out-of-bounds Read, Improper Null Termination, Incorrect Calculation of Buffer Size, Path Traversal: '../filedir', Reachable Assertion, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Use of Password Hash With Insufficient Computational Effort, Out-of-bounds Write, Incorrect Privilege Assignment, Improper Control of Generation of Code ('Code Injection'), Improper Authentication, Stack-based Buffer Overflow, NULL Pointer Dereference, Missing Initialization of Resource, Null Byte Interaction Error (Poison Null Byte), Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Preservation of Permissions, Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Integer Overflow or Wraparound, Uncontrolled Recursion, URL Redirection to Untrusted Site ('Open Redirect'), Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting'), Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Free of Memory not on the Heap, Use of Uninitialized Resource, Improper Handling of Invalid Use of Special Elements, Improper Use of Validation Framework</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Communications, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11036</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When processing certain files, PHP EXIF extension in versions 7.1.x below 7.1.29, 7.2.x below 7.2.18 and 7.3.x below 7.3.5 can be caused to read past allocated buffer in exif_process_IFD_TAG function. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11036\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/126.html\">CWE-126 Buffer Over-read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-25727</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In phpMyAdmin before 4.9.11 and 5.x before 5.2.1, an authenticated user can trigger XSS by uploading a crafted .sql file through the drag-and-drop interface.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-25727\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2011</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Client product of Oracle MySQL (component: C API). Supported versions that are affected are 5.7.32 and prior and 8.0.22 and prior. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise MySQL Client. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Client.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2011\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32083</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.2 to v10.6.1 was discovered to contain a segmentation fault via the component Item_subselect::init_expr_cache_tracker.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32083\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46668</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows an application crash via certain long SELECT DISTINCT statements that improperly interact with storage-engine resource limitations for temporary data structures.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46668\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-19518</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>University of Washington IMAP Toolkit 2007f on UNIX, as used in imap_open() in PHP and other products, launches an rsh command (by means of the imap_rimap function in c-client/imap4r1.c and the tcp_aopen function in osdep/unix/tcp_unix.c) without preventing argument injection, which might allow remote attackers to execute arbitrary OS commands if the IMAP server name is untrusted input (e.g., entered by a user of a web application) and if rsh has been replaced by a program with different argument semantics. For example, if rsh is a link to ssh (as seen on Debian and Ubuntu systems), then the attack can use an IMAP server name containing a \"-oProxyCommand\" argument.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-19518\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/88.html\">CWE-88 Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2194</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.33 and prior and 8.0.23 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2194\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11049</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.13 and 7.4.0 on Windows, when supplying custom headers to mail() function, due to mistake introduced in commit 78f4b4a2dcf92ddbccea1bb95f8390a18ac3342e, if the header is supplied in lowercase, this can result in double-freeing certain memory locations.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11049\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/415.html\">CWE-415 Double Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31626</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.4.x below 7.4.30, 8.0.x below 8.0.20, and 8.1.x below 8.1.7, when pdo_mysql extension with mysqlnd driver, if the third party is allowed to supply host to connect to and the password for the connection, password of excessive length can trigger a buffer overflow in PHP, which can lead to a remote code execution vulnerability.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-31626\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32084</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.2 to v10.7 was discovered to contain a segmentation fault via the component sub_select.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32084\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32088</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.2 to v10.7 was discovered to contain a segmentation fault via the component Exec_time_tracker::get_loops/Filesort_tracker::report_use/filesort.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32088\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27377</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.3 and below was discovered to contain an use-after-free in the component Item_func_in::cleanup(), which is exploited via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27377\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2922</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Client product of Oracle MySQL (component: C API). Supported versions that are affected are 5.6.47 and prior, 5.7.29 and prior and 8.0.18 and prior. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise MySQL Client. Successful attacks of this vulnerability can result in unauthorized read access to a subset of MySQL Client accessible data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2922\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/200.html\">CWE-200 Exposure of Sensitive Information to an Unauthorized Actor</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.7</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9638</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the EXIF component in PHP before 7.1.27, 7.2.x before 7.2.16, and 7.3.x before 7.3.3. There is an uninitialized read in exif_process_IFD_in_MAKERNOTE because of mishandling the maker_note-&gt;offset relationship to value_len.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9638\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11044</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0 on Windows, PHP link() function accepts filenames with embedded \\0 byte and treats them as terminating at that byte. This could lead to security vulnerabilities, e.g. in applications checking paths that the code is allowed to access.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11044\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/170.html\">CWE-170 Improper Null Termination</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7068</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.33, 7.3.x below 7.3.21 and 7.4.x below 7.4.9, while processing PHAR files using phar extension, phar_parse_zipfile could be tricked into accessing freed memory, which could lead to a crash or information disclosure.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7068\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.6</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:L\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7069</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.34, 7.3.x below 7.3.23 and 7.4.x below 7.4.11, when AES-CCM mode is used with openssl_encrypt() function with 12 bytes IV, only first 7 bytes of the IV is actually used. This can lead to both decreased security and incorrect encryption data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7069\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-2301</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Use-after-free vulnerability in the phar_rename_archive function in phar_object.c in PHP before 5.5.22 and 5.6.x before 5.6.6 allows remote attackers to cause a denial of service or possibly have unspecified other impact via vectors that trigger an attempted renaming of a Phar archive to the name of an existing file.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2015-2301\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-0568</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, core path resolution function allocate buffer one byte too small. When resolving paths with lengths close to system MAXPATHLEN setting, this may lead to the byte after the allocated buffer being overwritten with NUL value, which might lead to unauthorized data access or modification.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-0568\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/131.html\">CWE-131 Incorrect Calculation of Buffer Size</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27458</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.3 and below was discovered to contain an use-after-free in the component Binary_string::free_buffer() at /sql/sql_string.h.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27458\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21706</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.31, 7.4.x below 7.4.24 and 8.0.x below 8.0.11, in Microsoft Windows environment, ZipArchive::extractTo may be tricked into writing a file outside target directory when extracting a ZIP file, thus potentially causing files to be created or overwritten, subject to OS permissions.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21706\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/24.html\">CWE-24 Path Traversal: '../filedir'</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27452</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/item_cmpfunc.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27452\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7071</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.26, 7.4.x below 7.4.14 and 8.0.0, when validating URL with functions like filter_var($url, FILTER_VALIDATE_URL), PHP will accept an URL with invalid password as valid URL. This may lead to functions that rely on URL being valid to mis-parse the URL and produce wrong data as components of the URL.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7071\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27387</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.7 and below was discovered to contain a global buffer overflow in the component decimal_bin_size, which is exploited via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27387\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27376</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.5 and below was discovered to contain an use-after-free in the component Item_args::walk_arg, which is exploited via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27376\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11043</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.1.x below 7.1.33, 7.2.x below 7.2.24 and 7.3.x below 7.3.11 in certain configurations of FPM setup it is possible to cause FPM module to write past allocated buffers into the space reserved for FCGI protocol data, thus opening the possibility of remote code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11043\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2032</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Information Schema). Supported versions that are affected are 5.7.32 and prior and 8.0.22 and prior. Easily exploitable vulnerability allows low privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized read access to a subset of MySQL Server accessible data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2032\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2007</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Client product of Oracle MySQL (component: C API). Supported versions that are affected are 5.6.47 and prior, 5.7.29 and prior and 8.0.19 and prior. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise MySQL Client. Successful attacks of this vulnerability can result in unauthorized read access to a subset of MySQL Client accessible data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2007\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.7</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11045</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0, PHP DirectoryIterator class accepts filenames with embedded \\0 byte and treats them as terminating at that byte. This could lead to security vulnerabilities, e.g. in applications checking paths that the code is allowed to access.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11045\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/170.html\">CWE-170 Improper Null Termination</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27445</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/sql_window.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27445\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27457</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.3 and below was discovered to contain an use-after-free in the component my_mb_wc_latin1 at /strings/ctype-latin1.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27457\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27384</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component Item_subselect::init_expr_cache_tracker of MariaDB Server v10.6 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27384\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-23808</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in phpMyAdmin 5.1 before 5.1.2. An attacker can inject malicious code into aspects of the setup script, which can allow XSS or HTML injection.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-23808\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-0567</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, password_verify() function may accept some invalid Blowfish hashes as valid. If such invalid hash ever ends up in the password database, it may lead to an application allowing any password for this entry as valid.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-0567\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/916.html\">CWE-916 Use of Password Hash With Insufficient Computational Effort</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.2</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9025</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP 7.3.x before 7.3.1. An invalid multibyte string supplied as an argument to the mb_split() function in ext/mbstring/php_mbregex.c can cause PHP to execute memcpy() with a negative argument, which could read and write past buffers allocated for the data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9025\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27379</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component Arg_comparator::compare_real_fixed of MariaDB Server v10.6.2 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27379\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9637</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 7.1.27, 7.2.x before 7.2.16, and 7.3.x before 7.3.3. Due to the way rename() across filesystems is implemented, it is possible that file being renamed is briefly available with wrong permissions while the rename is ongoing, thus enabling unauthorized users to access the data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9637\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/266.html\">CWE-266 Incorrect Privilege Assignment</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-27928</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A remote code execution issue was discovered in MariaDB 10.2 before 10.2.37, 10.3 before 10.3.28, 10.4 before 10.4.18, and 10.5 before 10.5.9; Percona Server through 2021-03-03; and the wsrep patch through 2021-03-03 for MySQL. An untrusted search path leads to eval injection, in which a database SUPER user can execute OS commands after modifying wsrep_provider and wsrep_notify_cmd. NOTE: this does not affect an Oracle product.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-27928\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21703</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x up to and including 7.3.31, 7.4.x below 7.4.25 and 8.0.x below 8.0.12, when running PHP FPM SAPI with main FPM daemon process running as root and child worker processes running as lower-privileged users, it is possible for the child processes to access memory shared with the main process and write to it, modifying it in a way that would cause the root process to conduct invalid memory reads and writes, which can be used to escalate privileges from local unprivileged user to the root user.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21703\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2760</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.29 and prior and 8.0.19 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server as well as unauthorized update, insert or delete access to some of MySQL Server accessible data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2760\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2166</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: DML). Supported versions that are affected are 5.7.33 and prior and 8.0.23 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2166\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-2787</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Use-after-free vulnerability in the process_nested_data function in ext/standard/var_unserializer.re in PHP before 5.4.39, 5.5.x before 5.5.23, and 5.6.x before 5.6.7 allows remote attackers to execute arbitrary code via a crafted unserialize call that leverages use of the unset function within an __wakeup function, a related issue to CVE-2015-0231.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2015-2787\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-23807</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in phpMyAdmin 4.9 before 4.9.8 and 5.1 before 5.1.2. A valid user who is already authenticated to phpMyAdmin can manipulate their account to bypass two-factor authentication for future login instances.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-23807\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/287.html\">CWE-287 Improper Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2752</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Client product of Oracle MySQL (component: C API). Supported versions that are affected are 5.6.47 and prior, 5.7.27 and prior and 8.0.17 and prior. Difficult to exploit vulnerability allows low privileged attacker with network access via multiple protocols to compromise MySQL Client. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Client.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2752\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46666</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB before 10.6.2 allows an application crash because of mishandling of a pushdown from a HAVING clause to a WHERE clause.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46666\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2814</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.6.47 and prior, 5.7.28 and prior and 8.0.18 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2814\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7065</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.16 and 7.4.x below 7.4.4, while using mb_strtolower() function with UTF-32LE encoding, certain invalid strings could cause PHP to overwrite stack-allocated buffer. This could lead to memory corruption, crashes and potentially code execution.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7065\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21705</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.29, 7.4.x below 7.4.21 and 8.0.x below 8.0.8, when using URL validation functionality via filter_var() function with FILTER_VALIDATE_URL parameter, an URL with invalid password field can be accepted as valid. This can lead to the code incorrectly parsing the URL and potentially leading to other security implications - like contacting a wrong server or making a wrong access decision.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21705\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7062</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.28, 7.3.x below 7.3.15 and 7.4.x below 7.4.3, when using file upload functionality, if upload progress tracking is enabled, but session.upload_progress.cleanup is set to 0 (disabled), and the file upload fails, the upload procedure would try to clean up data that does not exist and encounter null pointer dereference, which would likely lead to a crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7062\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11039</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Function iconv_mime_decode_headers() in PHP versions 7.1.x below 7.1.30, 7.2.x below 7.2.19 and 7.3.x below 7.3.6 may perform out-of-buffer read due to integer overflow when parsing MIME headers. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11039\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11035</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When processing certain files, PHP EXIF extension in versions 7.1.x below 7.1.28, 7.2.x below 7.2.17 and 7.3.x below 7.3.4 can be caused to read past allocated buffer in exif_iif_add_value function. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11035\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27447</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a use-after-free via the component Binary_string::free_buffer() at /sql/sql_string.h.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27447\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11046</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0, PHP bcmath extension functions on some systems, including Windows, can be tricked into reading beyond the allocated space by supplying it with string containing characters that are identified as numeric by the OS but aren't ASCII numbers. This can read to disclosure of the content of some memory locations.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11046\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27446</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/item_cmpfunc.h.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27446\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.7 and below was discovered to contain a segmentation fault via the component sql/sql_class.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9639</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the EXIF component in PHP before 7.1.27, 7.2.x before 7.2.16, and 7.3.x before 7.3.3. There is an uninitialized read in exif_process_IFD_in_MAKERNOTE because of mishandling the data_len variable.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9639\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/909.html\">CWE-909 Missing Initialization of Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11042</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When PHP EXIF extension is parsing EXIF information from an image, e.g. via exif_read_data() function, in PHP versions 7.1.x below 7.1.31, 7.2.x below 7.2.21 and 7.3.x below 7.3.8 it is possible to supply it with data what will cause it to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11042\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component Used_tables_and_const_cache::used_tables_and_const_cache_join of MariaDB Server v10.7 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7059</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When using fgetss() function to read data with stripping tags, in PHP versions 7.2.x below 7.2.27, 7.3.x below 7.3.14 and 7.4.x below 7.4.2 it is possible to supply data that will cause this function to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7059\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7070</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.34, 7.3.x below 7.3.23 and 7.4.x below 7.4.11, when PHP is processing incoming HTTP cookie values, the cookie names are url-decoded. This may lead to cookies with prefixes like __Host confused with cookies that decode to such prefix, thus leading to an attacker being able to forge cookie which is supposed to be secure. See also CVE-2020-8184 for more information.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7070\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32091</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.7 was discovered to contain an use-after-poison in in __interceptor_memset at /libsanitizer/sanitizer_common/sanitizer_common_interceptors.inc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32091\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-2348</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The move_uploaded_file implementation in ext/standard/basic_functions.c in PHP before 5.4.39, 5.5.x before 5.5.23, and 5.6.x before 5.6.7 truncates a pathname upon encountering a \\x00 character, which allows remote attackers to bypass intended extension restrictions and create files with unexpected names via a crafted second argument. NOTE: this vulnerability exists because of an incomplete fix for CVE-2006-7243.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2015-2348\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/626.html\">CWE-626 Null Byte Interaction Error (Poison Null Byte)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9020</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 5.6.40, 7.x before 7.1.26, 7.2.x before 7.2.14, and 7.3.x before 7.3.1. Invalid input to the function xmlrpc_decode() can lead to an invalid memory access (heap out of bounds read or read after free). This is related to xml_elem_parse_buf in ext/xmlrpc/libxmlrpc/xml_element.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9020\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-35604</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.35 and prior and 8.0.26 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server as well as unauthorized update, insert or delete access to some of MySQL Server accessible data.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-35604\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27444</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/item_subselect.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27444\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-14883</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 5.6.37, 7.0.x before 7.0.31, 7.1.x before 7.1.20, and 7.2.x before 7.2.8. An Integer Overflow leads to a heap-based buffer over-read in exif_thumbnail_extract of exif.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-14883\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2014-9705</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Heap-based buffer overflow in the enchant_broker_request_dict function in ext/enchant/enchant.c in PHP before 5.4.38, 5.5.x before 5.5.22, and 5.6.x before 5.6.6 allows remote attackers to execute arbitrary code via vectors that trigger creation of multiple dictionaries.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2014-9705\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7064</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.9, 7.3.x below 7.3.16 and 7.4.x below 7.4.4, while parsing EXIF data with exif_read_data() function, it is possible for malicious data to cause PHP to read one byte of uninitialized memory. This could potentially lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7064\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27382</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.7 and below was discovered to contain a segmentation fault via the component Item_field::used_tables/update_depend_map_for_order.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27382\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7063</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.28, 7.3.x below 7.3.15 and 7.4.x below 7.4.3, when creating PHAR archive using PharData::buildFromIterator() function, the files are added with default permissions (0666, or all access) even if the original files on the filesystem were with more restrictive permissions. This may result in files having more lax permissions than intended when such archive is extracted.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7063\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/281.html\">CWE-281 Improper Preservation of Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2372</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.34 and prior and 8.0.25 and prior. Difficult to exploit vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2372\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9021</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 5.6.40, 7.x before 7.1.26, 7.2.x before 7.2.14, and 7.3.x before 7.3.1. A heap-based buffer over-read in PHAR reading functions in the PHAR extension may allow an attacker to read allocated or unallocated memory past the actual data when trying to parse the file name, a different vulnerability than CVE-2018-20783. This is related to phar_detect_phar_fname_ext in ext/phar/phar.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9021\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-14851</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>exif_process_IFD_in_MAKERNOTE in ext/exif/exif.c in PHP before 5.6.37, 7.0.x before 7.0.31, 7.1.x before 7.1.20, and 7.2.x before 7.2.8 allows remote attackers to cause a denial of service (out-of-bounds read and application crash) via a crafted JPEG file.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-14851\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27448</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is an Assertion failure in MariaDB Server v10.9 and below via 'node-&gt;pcur-&gt;rel_pos == BTR_PCUR_ON' at /row/row0mysql.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27448\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.13 allows a ha_maria::extra application crash via certain SELECT statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2180</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.33 and prior and 8.0.23 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2180\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2014-9709</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The GetCode_ function in gd_gif_in.c in GD 2.1.1 and earlier, as used in PHP before 5.5.21 and 5.6.x before 5.6.5, allows remote attackers to cause a denial of service (buffer over-read and application crash) via a crafted GIF image that is improperly handled by the gdImageCreateFromGif function.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2014-9709\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-25690</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Some mod_proxy configurations on Apache HTTP Server versions 2.4.0 through 2.4.55 allow a HTTP Request Smuggling attack. Configurations are affected when mod_proxy is enabled along with some form of RewriteRule or ProxyPassMatch in which a non-specific pattern matches some portion of the user-supplied request-target (URL) data and is then re-inserted into the proxied request-target using variable substitution. For example, something like: RewriteEngine on RewriteRule \"^/here/(.*)\" \"http://example.com:8080/elsewhere?$1\"; [P] ProxyPassReverse /here/ http://example.com:8080/Request splitting/smuggling could result in bypass of access controls in the proxy server, proxying unintended URLs to existing origin servers, and cache poisoning. Users are recommended to update to at least version 2.4.56 of Apache HTTP Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-25690\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/444.html\">CWE-444 Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32082</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.5 to v10.7 was discovered to contain an assertion failure at table-&gt;get_ref_count() == 0 in dict0dict.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32082\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31629</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions before 7.4.31, 8.0.24 and 8.1.11, the vulnerability enables network and same-site attackers to set a standard insecure cookie in the victim's browser which is treated as a `__Host-` or `__Secure-` cookie by PHP applications.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-31629\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9022</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP 7.x before 7.1.26, 7.2.x before 7.2.14, and 7.3.x before 7.3.2. dns_get_record misparses a DNS response, which can allow a hostile DNS server to cause PHP to misuse memcpy, leading to read operations going past the buffer allocated for DNS data. This affects php_parserr in ext/standard/dns.c for DNS_CAA and DNS_ANY queries.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9022\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2016-3078</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple integer overflows in php_zip.c in the zip extension in PHP before 7.0.6 allow remote attackers to cause a denial of service (heap-based buffer overflow and application crash) or possibly have unspecified other impact via a crafted call to (1) getFromIndex or (2) getFromName in the ZipArchive class.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2016-3078\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-0662</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, excessive number of parts in HTTP form upload can cause high resource consumption and excessive number of log entries. This can cause denial of service on the affected server by exhausting CPU resources or disk space.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-0662\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2022</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.6.50 and prior, 5.7.32 and prior and 8.0.22 and prior. Difficult to exploit vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2022\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32089</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.5 to v10.7 was discovered to contain a segmentation fault via the component st_select_lex_unit::exclude_level.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32089\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11048</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.31, 7.3.x below 7.3.18 and 7.4.x below 7.4.6, when HTTP file uploads are allowed, supplying overly long filenames or field names could lead PHP engine to try to allocate oversized memory storage, hit the memory limit and stop processing the request, without cleaning up temporary files created by upload request. This potentially could lead to accumulation of uncleaned temporary files exhausting the disk space on the target server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11048\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46669</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows attackers to trigger a convert_const_to_int use-after-free when the BIGINT data type is used.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46669\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11047</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When PHP EXIF extension is parsing EXIF information from an image, e.g. via exif_read_data() function, in PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0 it is possible to supply it with data what will cause it to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11047\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27383</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6 and below was discovered to contain an use-after-free in the component my_strcasecmp_8bit, which is exploited via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27383\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46667</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB before 10.6.5 has a sql_lex.cc integer overflow, leading to an application crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46667\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32087</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.2 to v10.7 was discovered to contain a segmentation fault via the component Item_args::walk_args.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32087\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-36760</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Inconsistent Interpretation of HTTP Requests ('HTTP Request Smuggling') vulnerability in mod_proxy_ajp of Apache HTTP Server allows an attacker to smuggle requests to the AJP server it forwards requests to. This issue affects Apache HTTP Server Apache HTTP Server 2.4 version 2.4.54 and prior versions.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-36760\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/444.html\">CWE-444 Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7060</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When using certain mbstring functions to convert multibyte encodings, in PHP versions 7.2.x below 7.2.27, 7.3.x below 7.3.14 and 7.4.x below 7.4.2 it is possible to supply data that will cause function mbfl_filt_conv_big5_wchar to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7060\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-17082</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Apache2 component in PHP before 5.6.38, 7.0.x before 7.0.32, 7.1.x before 7.1.22, and 7.2.x before 7.2.10 allows XSS via the body of a \"Transfer-Encoding: chunked\" request, because the bucket brigade is mishandled in the php_handler function in sapi/apache2handler/sapi_apache2.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-17082\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9640</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the EXIF component in PHP before 7.1.27, 7.2.x before 7.2.16, and 7.3.x before 7.3.3. There is an Invalid Read in exif_process_SOFn.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9640\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46661</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows an application crash in find_field_in_tables and find_order_in_list via an unused common table expression (CTE).</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46661\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11034</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When processing certain files, PHP EXIF extension in versions 7.1.x below 7.1.28, 7.2.x below 7.2.17 and 7.3.x below 7.3.4 can be caused to read past allocated buffer in exif_process_IFD_TAG function. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11034\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27456</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.3 and below was discovered to contain an use-after-free in the component VDec::VDec at /sql/sql_type.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27456\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7061</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.15 and 7.4.x below 7.4.3, while extracting PHAR files on Windows using phar extension, certain content inside PHAR file could lead to one-byte read past the allocated buffer. This could potentially lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7061\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27455</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.6.3 and below was discovered to contain an use-after-free in the component my_wildcmp_8bit_impl at /strings/ctype-simple.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27455\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2144</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: Parser). Supported versions that are affected are 5.7.29 and prior and 8.0.19 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in takeover of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2144\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2154</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: DML). Supported versions that are affected are 5.7.33 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2154\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-21595</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: C API). Supported versions that are affected are 5.7.36 and prior and 8.0.27 and prior. Difficult to exploit vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-21595\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11040</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When PHP EXIF extension is parsing EXIF information from an image, e.g. via exif_read_data() function, in PHP versions 7.1.x below 7.1.30, 7.2.x below 7.2.19 and 7.3.x below 7.3.6 it is possible to supply it with data what will cause it to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11040\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2389</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.34 and prior and 8.0.25 and prior. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2389\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-27522</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>HTTP Response Smuggling vulnerability in Apache HTTP Server via mod_proxy_uwsgi. This issue affects Apache HTTP Server: from 2.4.30 through 2.4.55. Special characters in the origin response header can truncate/split the response forwarded to the client.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2023-27522\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/444.html\">CWE-444 Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2812</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: Stored Procedure). Supported versions that are affected are 5.6.47 and prior, 5.7.29 and prior and 8.0.19 and prior. Easily exploitable vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2812\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46665</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows a sql_parse.cc application crash because of incorrect used_tables expectations.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46665\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32086</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.4 to v10.8 was discovered to contain a segmentation fault via the component Item_field::fix_outer_field.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32086\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32085</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.2 to v10.7 was discovered to contain a segmentation fault via the component Item_func_in::cleanup/Item::cleanup_processor.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32085\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/229.html\">CWE-229 Improper Handling of Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21704</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.29, 7.4.x below 7.4.21 and 8.0.x below 8.0.8, when using Firebird PDO driver extension, a malicious database server could cause crashes in various database functions, such as getAttribute(), execute(), fetch() and others by returning invalid response data that is not parsed correctly by the driver. This can result in crashes, denial of service or potentially memory corruption.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21704\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7066</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.2.x below 7.2.29, 7.3.x below 7.3.16 and 7.4.x below 7.4.4, while using get_headers() with user-supplied URL, if the URL contains zero (\\0) character, the URL will be silently truncated at it. This may cause some software to make incorrect assumptions about the target of the get_headers() and possibly send some information to a wrong server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-7066\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/170.html\">CWE-170 Improper Null Termination</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31628</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions before 7.4.31, 8.0.24 and 8.1.11, the phar uncompressor code would recursively uncompress \"quines\" gzip files, resulting in an infinite loop.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-31628\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/674.html\">CWE-674 Uncontrolled Recursion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46662</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows a set_var.cc application crash via certain uses of an UPDATE statement in conjunction with a nested subquery.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46662\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2016-5385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>PHP through 7.0.8 does not attempt to address RFC 3875 section 4.1.18 namespace conflicts and therefore does not protect applications from the presence of untrusted client data in the HTTP_PROXY environment variable, which might allow remote attackers to redirect an application's outbound HTTP traffic to an arbitrary proxy server via a crafted Proxy header in an HTTP request, as demonstrated by (1) an application that makes a getenv('HTTP_PROXY') call or (2) a CGI configuration of PHP, aka an \"httpoxy\" issue.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2016-5385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/601.html\">CWE-601 URL Redirection to Untrusted Site ('Open Redirect')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-37436</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Prior to Apache HTTP Server 2.4.55, a malicious backend can cause the response headers to be truncated early, resulting in some headers being incorporated into the response body. If the later headers have any security purpose, they will not be interpreted by the client.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-37436\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/113.html\">CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2013-6501</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The default soap.wsdl_cache_dir setting in (1) php.ini-production and (2) php.ini-development in PHP through 5.6.7 specifies the /tmp directory, which makes it easier for local users to conduct WSDL injection attacks by creating a file under /tmp with a predictable filename that is used by the get_sdl function in ext/soap/php_sdl.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2013-6501\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/74.html\">CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21702</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.27, 7.4.x below 7.4.15 and 8.0.x below 8.0.2, when using SOAP extension to connect to a SOAP server, a malicious SOAP server could return malformed XML data as a response that would cause PHP to access a null pointer and thus cause a crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21702\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9024</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 5.6.40, 7.x before 7.1.26, 7.2.x before 7.2.14, and 7.3.x before 7.3.1. xmlrpc_decode() can allow a hostile XMLRPC server to cause PHP to read memory outside of allocated areas in base64_decode_xmlrpc in ext/xmlrpc/libxmlrpc/base64.c.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9024\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9023</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in PHP before 5.6.40, 7.x before 7.1.26, 7.2.x before 7.2.14, and 7.3.x before 7.3.1. A number of heap-based buffer over-read instances are present in mbstring regular expression functions when supplied with invalid multibyte data. These occur in ext/mbstring/oniguruma/regcomp.c, ext/mbstring/oniguruma/regexec.c, ext/mbstring/oniguruma/regparse.c, ext/mbstring/oniguruma/enc/unicode.c, and ext/mbstring/oniguruma/src/utf32_be.c when a multibyte regular expression pattern contains invalid multibyte sequences.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9023\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27449</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/item_func.cc:148.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27449\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-46664</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB through 10.5.9 allows an application crash in sub_select_postjoin_aggr for a NULL value of aggr.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-46664\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11050</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When PHP EXIF extension is parsing EXIF information from an image, e.g. via exif_read_data() function, in PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0 it is possible to supply it with data what will cause it to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11050\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21708</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.4.x below 7.4.28, 8.0.x below 8.0.16, and 8.1.x below 8.1.3, when using filter functions with FILTER_VALIDATE_FLOAT filter and min/max limits, if the filter fails, there is a possibility to trigger use of allocated memory after free, which can result it crashes, and potentially in overwrite of other memory chunks and RCE. This issue affects: code that uses FILTER_VALIDATE_FLOAT with min/max limits.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21708\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31625</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.4.x below 7.4.30, 8.0.x below 8.0.20, and 8.1.x below 8.1.7, when using Postgres database extension, supplying invalid parameters to the parametrized query may lead to PHP attempting to free memory using uninitialized data as pointers. This could lead to RCE vulnerability or denial of service.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-31625\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/590.html\">CWE-590 Free of Memory not on the Heap</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32081</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB v10.4 to v10.7 was discovered to contain an use-after-poison in prepare_inplace_add_virtual at /storage/innobase/handler/handler0alter.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-32081\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27378</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component Create_tmp_table::finalize of MariaDB Server v10.7 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27378\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2006-20001</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A carefully crafted If: request header can cause a memory read, or write of a single zero byte, in a pool (heap) memory location beyond the header value sent. This could cause the process to crash. This issue affects Apache HTTP Server 2.4.54 and earlier.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2006-20001\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-19935</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>ext/imap/php_imap.c in PHP 5.x and 7.x before 7.3.0 allows remote attackers to cause a denial of service (NULL pointer dereference and application crash) via an empty string in the message argument to the imap_mail function.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-19935\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4900</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability was found in PHP where setting the environment variable PHP_CLI_SERVER_WORKERS to a large value leads to a heap buffer overflow.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-4900\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-12882</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>exif_read_from_impl in ext/exif/exif.c in PHP 7.2.x through 7.2.7 allows attackers to trigger a use-after-free (in exif_read_from_file) because it closes a stream that it is not responsible for closing. The vulnerable code is reachable through the PHP exif_read_data function.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2018-12882\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9641</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the EXIF component in PHP before 7.1.27, 7.2.x before 7.2.16, and 7.3.x before 7.3.3. There is an uninitialized read in exif_process_IFD_in_TIFF.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-9641\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/908.html\">CWE-908 Use of Uninitialized Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27380</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component my_decimal::operator= of MariaDB Server v10.6.3 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27380\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27381</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the component Field::set_default of MariaDB Server v10.6 and below was discovered to allow attackers to cause a Denial of Service (DoS) via specially crafted SQL statements.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27381\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21707</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In PHP versions 7.3.x below 7.3.33, 7.4.x below 7.4.26 and 8.0.x below 8.0.13, certain XML parsing functions, like simplexml_load_file(), URL-decode the filename passed to them. If that filename contains URL-encoded NUL character, this may cause the function to interpret this as the end of the filename, thus interpreting the filename differently from what the user intended, which may lead it to reading a different file than intended.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-21707\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/159.html\">CWE-159 Improper Handling of Invalid Use of Special Elements</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-27451</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MariaDB Server v10.9 and below was discovered to contain a segmentation fault via the component sql/field_conv.cc.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2022-27451\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1173.html\">CWE-1173 Improper Use of Validation Framework</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-2780</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: Server: DML). Supported versions that are affected are 5.6.47 and prior, 5.7.29 and prior and 8.0.19 and prior. Easily exploitable vulnerability allows low privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2020-2780\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11041</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When PHP EXIF extension is parsing EXIF information from an image, e.g. via exif_read_data() function, in PHP versions 7.1.x below 7.1.31, 7.2.x below 7.2.21 and 7.3.x below 7.3.8 it is possible to supply it with data what will cause it to read past the allocated buffer. This may lead to information disclosure or crash.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2019-11041\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-2174</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Vulnerability in the MySQL Server product of Oracle MySQL (component: InnoDB). Supported versions that are affected are 5.7.33 and prior and 8.0.23 and prior. Difficult to exploit vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Server.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2021-2174\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Festo Didactic SE MES PC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Festo Didactic SE</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Festo Didactic SE MES PC shipped with Windows 10</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CERT@VDE helped coordinate and support this publication</li>\n</ul>\n<hr>\n<h2>General recommendation</h2>\n<p>Festo Didactic offers products with security functions that aid the safe operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks from cyber threats, a comprehensive security concept must be implemented and continuously updated. Festo products and services only constitute one part of such a concept. The customer is responsible for preventing unauthorized access to their plants, systems, machines and networks. Systems, machines and components should only be connected to a company's network or the Internet if and as necessary, and only when the suitable security measures (e.g., firewalls and network segmentation, defense-in-depth) are in place. Failure to ensure adequate security measures when connecting the product to the network can result in vulnerabilities which allow unauthorized, remote access to the network - even beyond the product boundaries. This access could be abused to incur a loss of data or manipulate or sabotage systems. Typical forms of attack include but are not limited to: Denial-of-Service (rendering the system temporarily non-functional), remote execution of malicious code, privilege escalation (executing malicious code with higher system privileges than expected), ransomware (encryption of data and demanding payment for decryption). In the context of industrial systems and machines this can also lead to unsafe states, posing a danger to people and equipment. Furthermore, Festo guidelines on suitable security measures should be observed. Festo products and solutions are constantly being developed further in order to make them more secure. Festo strongly recommends that customers install product updates as soon as they become available and always use the latest versions of its products. Any use of product versions that are no longer supported or any failure to install the latest updates may render the customer vulnerable to cyber-attacks.</p>\n<hr>\n<h2>Disclaimer</h2>\n<p>Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment, or liability on the part of Festo.\\n\\nNote: In no case does this information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.\\n\\nIn addition, the actual general terms, and conditions for delivery, payment and software use of Festo, available under http://www.festo.com and the special provisions for the use of Festo Security Advisory available at https://www.festo.com/psirt shall apply.</p>\n<hr>\n<h2>Impact</h2>\n<p>The vulnerabilities covered by this advisory have a broad range of impacts ranging from denial-of-service to disclosure or manipulation/deletion of information. Given the intended usage of MES PCs for didactic purposes in controlled lab environments, separate from productive systems, it never comes into contact with sensitive information. Therefore the impact is reduced to limited availability of the system.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Festo SE &amp; Co. KG FSA-202402 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Festo SE &amp; Co. KG directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2024-02-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2024-02-27</td>\n<td>1</td>\n<td>Initial version</td>\n</tr>\n<tr>\n<td>2025-11-04</td>\n<td>2</td>\n<td>Adjust to VDE template. Add missing CWE-IDs if available. Updated legal disclaimer to add references to special provisions.</td>\n</tr>\n<tr>\n<td>2025-12-08</td>\n<td>3</td>\n<td>Add all missing CWE identifier and CVSS 3.x scores.</td>\n</tr>\n<tr>\n<td>2026-01-27</td>\n<td>4</td>\n<td>Initial Republication of Festo SE &amp; Co. KG FSA-202402 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 27 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 27 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-03",
        "title": "Schneider Electric Zigbee Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-027-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of multiple vulnerabilities with EmberZNet disclosed by Silicon Labs. Many vendors, including Schneider Electric, use Silicon Labs\u2019 Zigbee processors in their offers. The following have denial of service vulnerabilities: Wiser iTRV, Wiser RTR, Wiser UFH, Wiser Heat Switch, Wiser Boiler Relay, cFMT (Exaact, Elko, Odace, Merten), Wiser Micromodule, Iconic Wiser Connected Smart Dimmer, Iconic Zigbee devices, Wiser Application Modules, Wiser Connected Pushbutton Switch/Dimmer/Shutter controller, Rotary Dimmer, Motion Sensor Dimmer/Switch, Smart socket outlets, and EV socket outlet. See the following table. Failure to apply the mitigations provided below may risk denial of service, which could result in products being unavailable.</strong></p>\n<p>The following versions of Schneider Electric Zigbee Products are affected:</p>\n<ul>\n<li>Wiser iTRV2 (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser iTRV3 (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser RTR2 (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser UFH (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser 16A Electrical Heat Switch (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Boiler Relay (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Exxact cFMT 16a (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Elko cFMT 16a (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Odace cFMT 2a (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Merten cFMT 16a (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Merten cFMT 2a (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Power Micromodule (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser FIP Micromodule (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Iconic, Wiser Connected Smart Dimmer (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Iconic, Wiser Connected Smart Switch, 2AX (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Iconic, Wiser Connected Smart Switch, 10AX (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Iconic, Connected AC Fan Controller (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Iconic, Connected Smart Socket (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Application Module 1-Gang (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Application Module 2-Gang (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Push Button Dimmer (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Push Button Switch (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Push Button Shutter (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Motion Dimmer (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Motion Switch (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Wiser Connected Rotary Dimmer (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Connected Wireless Switch (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Micromodule Switch (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Micromodule Dimmer (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Micromodule Shutter (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Connected Single Socket Outlet (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Connected Double Socket Outlet (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Fuga Connected Socket Outlet (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n<li>Mureva EV Link (CVE-2024-6350, CVE-2024-6351, CVE-2024-6352, CVE-2024-10106, CVE-2024-7322)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Zigbee Products</td>\n<td>Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Uncontrolled Resource Consumption</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-6350</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CWE-120: A buffer overflow vulnerability exists that could cause a denial of service when a malicious device joins the network.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2024-6350\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Zigbee Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Wiser iTRV2 All Versions, Wiser iTRV3 All Versions, Wiser RTR2 All Versions, Wiser UFH All Versions, Wiser 16A Electrical Heat Switch All Versions, Wiser Boiler Relay All Versions, Exxact cFMT 16a All Versions, Elko cFMT 16a All Versions, Odace cFMT 2a All Versions, Merten cFMT 16a All Versions, Merten cFMT 2a All Versions, Wiser Power Micromodule All Versions, Wiser FIP Micromodule All Versions, Iconic, Wiser Connected Smart Dimmer All Versions, Iconic, Wiser Connected Smart Switch, 2AX All Versions, Iconic, Wiser Connected Smart Switch, 10AX All Versions, Iconic, Connected AC Fan Controller All Versions, Iconic, Connected Smart Socket All Versions, Wiser Connected Application Module 1-Gang All Versions, Wiser Connected Application Module 2-Gang All Versions, Wiser Connected Push Button Dimmer All Versions, Wiser Connected Push Button Switch All Versions, Wiser Connected Push Button Shutter All Versions, Wiser Connected Motion Dimmer All Versions, Wiser Connected Motion Switch All Versions, Wiser Connected Rotary Dimmer All Versions, Connected Wireless Switch All Versions, Micromodule Switch All Versions, Micromodule Dimmer All Versions, Micromodule Shutter All Versions, Connected Single Socket Outlet All Versions, Connected Double Socket Outlet All Versions, Fuga Connected Socket Outlet All Versions, Mureva EV Link All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploit: To keep your Zigbee network safe and prevent unauthorized access: \u2022 Restrict device access: Do not allow unknown devices to join your network. \u2022 Review hub settings: Check how your Zigbee hub manages device pairing. \u2022 Control network availability: Only open the network when adding new devices and close it immediately after. \u2022 Use install codes and avoid the well-known key: Whenever possible, use unique install codes for added security. Replace default keys with secure, unique keys.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-6351</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CWE-120: A buffer overflow vulnerability exists that could cause a denial of service when a malicious device joins the network.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2024-6351\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Zigbee Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Wiser iTRV2 All Versions, Wiser iTRV3 All Versions, Wiser RTR2 All Versions, Wiser UFH All Versions, Wiser 16A Electrical Heat Switch All Versions, Wiser Boiler Relay All Versions, Exxact cFMT 16a All Versions, Elko cFMT 16a All Versions, Odace cFMT 2a All Versions, Merten cFMT 16a All Versions, Merten cFMT 2a All Versions, Wiser Power Micromodule All Versions, Wiser FIP Micromodule All Versions, Iconic, Wiser Connected Smart Dimmer All Versions, Iconic, Wiser Connected Smart Switch, 2AX All Versions, Iconic, Wiser Connected Smart Switch, 10AX All Versions, Iconic, Connected AC Fan Controller All Versions, Iconic, Connected Smart Socket All Versions, Wiser Connected Application Module 1-Gang All Versions, Wiser Connected Application Module 2-Gang All Versions, Wiser Connected Push Button Dimmer All Versions, Wiser Connected Push Button Switch All Versions, Wiser Connected Push Button Shutter All Versions, Wiser Connected Motion Dimmer All Versions, Wiser Connected Motion Switch All Versions, Wiser Connected Rotary Dimmer All Versions, Connected Wireless Switch All Versions, Micromodule Switch All Versions, Micromodule Dimmer All Versions, Micromodule Shutter All Versions, Connected Single Socket Outlet All Versions, Connected Double Socket Outlet All Versions, Fuga Connected Socket Outlet All Versions, Mureva EV Link All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploit: To keep your Zigbee network safe and prevent unauthorized access: \u2022 Restrict device access: Do not allow unknown devices to join your network. \u2022 Review hub settings: Check how your Zigbee hub manages device pairing. \u2022 Control network availability: Only open the network when adding new devices and close it immediately after. \u2022 Use install codes and avoid the well-known key: Whenever possible, use unique install codes for added security. Replace default keys with secure, unique keys.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-6352</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CWE-120: A buffer overflow vulnerability exists that could cause a denial of service when a malicious device joins the network.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2024-6352\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Zigbee Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Wiser iTRV2 All Versions, Wiser iTRV3 All Versions, Wiser RTR2 All Versions, Wiser UFH All Versions, Wiser 16A Electrical Heat Switch All Versions, Wiser Boiler Relay All Versions, Exxact cFMT 16a All Versions, Elko cFMT 16a All Versions, Odace cFMT 2a All Versions, Merten cFMT 16a All Versions, Merten cFMT 2a All Versions, Wiser Power Micromodule All Versions, Wiser FIP Micromodule All Versions, Iconic, Wiser Connected Smart Dimmer All Versions, Iconic, Wiser Connected Smart Switch, 2AX All Versions, Iconic, Wiser Connected Smart Switch, 10AX All Versions, Iconic, Connected AC Fan Controller All Versions, Iconic, Connected Smart Socket All Versions, Wiser Connected Application Module 1-Gang All Versions, Wiser Connected Application Module 2-Gang All Versions, Wiser Connected Push Button Dimmer All Versions, Wiser Connected Push Button Switch All Versions, Wiser Connected Push Button Shutter All Versions, Wiser Connected Motion Dimmer All Versions, Wiser Connected Motion Switch All Versions, Wiser Connected Rotary Dimmer All Versions, Connected Wireless Switch All Versions, Micromodule Switch All Versions, Micromodule Dimmer All Versions, Micromodule Shutter All Versions, Connected Single Socket Outlet All Versions, Connected Double Socket Outlet All Versions, Fuga Connected Socket Outlet All Versions, Mureva EV Link All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploit: To keep your Zigbee network safe and prevent unauthorized access: \u2022 Restrict device access: Do not allow unknown devices to join your network. \u2022 Review hub settings: Check how your Zigbee hub manages device pairing. \u2022 Control network availability: Only open the network when adding new devices and close it immediately after. \u2022 Use install codes and avoid the well-known key: Whenever possible, use unique install codes for added security. Replace default keys with secure, unique keys.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-10106</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CWE-120: A buffer overflow vulnerability exists that could cause a denial of service when a malicious device joins the network.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2024-10106\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Zigbee Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Wiser iTRV2 All Versions, Wiser iTRV3 All Versions, Wiser RTR2 All Versions, Wiser UFH All Versions, Wiser 16A Electrical Heat Switch All Versions, Wiser Boiler Relay All Versions, Exxact cFMT 16a All Versions, Elko cFMT 16a All Versions, Odace cFMT 2a All Versions, Merten cFMT 16a All Versions, Merten cFMT 2a All Versions, Wiser Power Micromodule All Versions, Wiser FIP Micromodule All Versions, Iconic, Wiser Connected Smart Dimmer All Versions, Iconic, Wiser Connected Smart Switch, 2AX All Versions, Iconic, Wiser Connected Smart Switch, 10AX All Versions, Iconic, Connected AC Fan Controller All Versions, Iconic, Connected Smart Socket All Versions, Wiser Connected Application Module 1-Gang All Versions, Wiser Connected Application Module 2-Gang All Versions, Wiser Connected Push Button Dimmer All Versions, Wiser Connected Push Button Switch All Versions, Wiser Connected Push Button Shutter All Versions, Wiser Connected Motion Dimmer All Versions, Wiser Connected Motion Switch All Versions, Wiser Connected Rotary Dimmer All Versions, Connected Wireless Switch All Versions, Micromodule Switch All Versions, Micromodule Dimmer All Versions, Micromodule Shutter All Versions, Connected Single Socket Outlet All Versions, Connected Double Socket Outlet All Versions, Fuga Connected Socket Outlet All Versions, Mureva EV Link All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploit: To keep your Zigbee network safe and prevent unauthorized access: \u2022 Restrict device access: Do not allow unknown devices to join your network. \u2022 Review hub settings: Check how your Zigbee hub manages device pairing. \u2022 Control network availability: Only open the network when adding new devices and close it immediately after. \u2022 Use install codes and avoid the well-known key: Whenever possible, use unique install codes for added security. Replace default keys with secure, unique keys.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.7</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-7322</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when a malicious device joins the network.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2024-7322\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Zigbee Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Wiser iTRV2 All Versions, Wiser iTRV3 All Versions, Wiser RTR2 All Versions, Wiser UFH All Versions, Wiser 16A Electrical Heat Switch All Versions, Wiser Boiler Relay All Versions, Exxact cFMT 16a All Versions, Elko cFMT 16a All Versions, Odace cFMT 2a All Versions, Merten cFMT 16a All Versions, Merten cFMT 2a All Versions, Wiser Power Micromodule All Versions, Wiser FIP Micromodule All Versions, Iconic, Wiser Connected Smart Dimmer All Versions, Iconic, Wiser Connected Smart Switch, 2AX All Versions, Iconic, Wiser Connected Smart Switch, 10AX All Versions, Iconic, Connected AC Fan Controller All Versions, Iconic, Connected Smart Socket All Versions, Wiser Connected Application Module 1-Gang All Versions, Wiser Connected Application Module 2-Gang All Versions, Wiser Connected Push Button Dimmer All Versions, Wiser Connected Push Button Switch All Versions, Wiser Connected Push Button Shutter All Versions, Wiser Connected Motion Dimmer All Versions, Wiser Connected Motion Switch All Versions, Wiser Connected Rotary Dimmer All Versions, Connected Wireless Switch All Versions, Micromodule Switch All Versions, Micromodule Dimmer All Versions, Micromodule Shutter All Versions, Connected Single Socket Outlet All Versions, Connected Double Socket Outlet All Versions, Fuga Connected Socket Outlet All Versions, Mureva EV Link All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers should immediately apply the following mitigations to reduce the risk of exploit: To keep your Zigbee network safe and prevent unauthorized access: \u2022 Restrict device access: Do not allow unknown devices to join your network. \u2022 Review hub settings: Check how your Zigbee hub manages device pairing. \u2022 Control network availability: Only open the network when adding new devices and close it immediately after. \u2022 Use install codes and avoid the well-known key: Whenever possible, use unique install codes for added security. Replace default keys with secure, unique keys.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported these vulnerabilities to CISA.</li>\n<li>Silicon Labs reported these vulnerabilities to Schneider Electric</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment. We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries. We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values. www.se.com</p>\n<hr>\n<h2>Vulnerability Details</h2>\n<p>These vulnerabilities disclosed by Silicon Labs affect their Zigbee processors, which are used in multiple Schneider Electric's products.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-013-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-13</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-13</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-01-27</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-013-03 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 27 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 27 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24858\" target=\"_blank\">CVE-2026-24858</a> Fortinet Multiple Products Authentication Bypass Using an Alternate Path or Channel Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 27 Jan 26 12:00:00 +0000",
        "last_updated": "Tue, 27 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/26/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Five Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/26/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added five new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-14634\" target=\"_blank\" data-entity-type=\"external\">CVE-2018-14634</a> Linux Kernel Integer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-52691\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-52691</a> SmarterTools SmarterMail Unrestricted Upload of File with Dangerous Type Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-21509\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-21509</a> Microsoft Office Security Feature Bypass Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-23760\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-23760</a> SmarterTools SmarterMail Authentication Bypass Using an Alternate Path or Channel Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24061\" target=\"_blank\" data-entity-type=\"external\">CVE-2026-24061</a> GNU InetUtils Argument Injection Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 26 Jan 26 12:00:00 +0000",
        "last_updated": "Mon, 26 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards",
        "title": "Product Categories for Technologies That Use Post-Quantum Cryptography Standards",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards",
        "summary": "<h2><strong>Executive Summary</strong></h2>\n<p>In response to the June 6, 2025, Executive Order (EO) 14306, \u201cSustaining Select Efforts to Strengthen the Nation\u2019s Cybersecurity and Amending Executive Order 13694 and Executive Order 14144,\u201d the Cybersecurity and Infrastructure Security Agency (CISA) is providing and regularly updating the below lists to aid in post-quantum cryptography (PQC) adoption. The lists include hardware and software categories with example types of widely available products that use PQC standards to protect sensitive information.<a href=\"#Note1\"><sup>1</sup></a> The lists focus on categories of available products, typically acquired by the federal government, that utilize cryptographic algorithms. Because PQC-capable products are widely available in the listed categories, organizations should acquire only PQC-capable products when planning acquisitions and procuring products in these categories. &nbsp;</p>\n<h2><strong>Introduction</strong></h2>\n<h3>Purpose</h3>\n<p>The lists below are CISA\u2019s response to Executive Order (EO) 14306, which instructed:</p>\n<p>By December 1, 2025, the Secretary of Homeland Security, acting through the Director of the Cybersecurity and Infrastructure Security Agency (CISA), and in consultation with the Director of the National Security Agency, shall release and thereafter regularly update a list of product categories in which products that support post-quantum cryptography (PQC) are widely available.</p>\n<p>When a particular category offers widely available PQC-capable products, organizations should plan acquisitions to procure only PQC-capable products from that category.</p>\n<h3>Scope and Definitions</h3>\n<p>The scope of the lists below includes categories of hardware and software products that are\u2014or are anticipated to be\u2014widely available and use PQC standards.&nbsp;</p>\n<p><strong>Note:</strong> \u201cWidely available\u201d describes products that are generally available in the marketplace, and agencies can acquire them in accordance with their typical procurement policies and procedures.</p>\n<p>The categories cover hardware and software products that apply PQC standards for encryption and authentication through the following cryptographic functions:</p>\n<ul>\n<li><strong>Key establishment:</strong><a href=\"#Note2\"><strong><sup>2</sup></strong></a> A function in the lifecycle of keying material; the process by which cryptographic keys are securely established among cryptographic modules using manual transport methods (e.g., key loaders), automated methods (e.g., key-transport and/or key-agreement protocols), or a combination of automated and manual methods (consisting of key transport plus key agreement).</li>\n<li><strong>Digital signatures:</strong><a href=\"#Note3\"><strong><sup>3</sup></strong></a><sup> </sup>The result of a cryptographic transformation of data that, when properly implemented, provides the services of 1. origin authentication, 2. data integrity, and 3. signer non-repudiation.&nbsp;</li>\n</ul>\n<p>Key establishment is often essential for establishing confidential communication using encryption among two or more parties. Digital signatures are often essential for authenticating the parties participating in a communication and for establishing the authenticity of data, products, and services.</p>\n<p>Automated cryptographic discovery and inventory products are out of scope of these lists.</p>\n<h2><strong>Considerations for Products That Use PQC Standards</strong></h2>\n<h3><strong>PQC Transition of Information Technology (IT) Infrastructure</strong></h3>\n<p>Recognizing the global need to support PQC algorithms, product manufacturers are developing new products and updating existing products to incorporate post-quantum cryptographic standards.&nbsp;</p>\n<h3>National Institute of Standards and Technology</h3>\n<p>In 2016, the National Institute of Standards and Technology (NIST) initiated a process to solicit, evaluate, and standardize one or more quantum-resistant public-key cryptographic algorithms. The ongoing PQC standardization process has produced PQC standards and will likely standardize additional algorithms in the coming years.</p>\n<p>The NIST Internal Report (IR) 8547, <em>Transition to Post-Quantum Cryptography Standards</em>, describes NIST\u2019s expected approach to transitioning from quantum-vulnerable cryptographic algorithms to post-quantum digital signature algorithms and key-establishment schemes. The report identifies existing quantum-vulnerable cryptographic standards and the current quantum-resistant standards that organizations will use in the transition. The report informs the efforts and timelines of federal agencies, industry, and standards organizations for transitioning products, services, and infrastructure to PQC. NIST will revise this report and feed into other algorithms- and application-specific guidance for the transition to PQC as necessary to support transition timelines.</p>\n<p><a href=\"#Table1\">Table 1</a> shows three NIST PQC standards along with a recommendation for stateful hash-based signature algorithms that support quantum-resistant standards.<br>&nbsp;<a class=\"ck-anchor\" id=\"Table1\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 1: NIST Standard PQC Algorithms</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\">Cryptographic Function</p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\">Algorithm Standard</p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Standard</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Key Establishment</td>\n<td>Module-Lattice-Based Key- Encapsulation Mechanism (ML-KEM)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/203/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 203</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Module-Lattice-Based Digital Signature Algorithm (ML-DSA)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/204/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 204</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Stateless Hash-Based Digital Signature Algorithm (SLH-DSA)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/fips/205/final\" target=\"_blank\">Federal Information Processing Standards (FIPS) 205</a></td>\n</tr>\n<tr>\n<td>Digital Signature</td>\n<td>Stateful Hash-Based Digital Signature Algorithms: Leighton-Micali Signature Scheme (LMS), Hierarchical Merkle Signature Scheme (HMS), eXtended Merkle Signature Scheme (XMSS), eXtended Merkle Signature Scheme with Multi-Tree (XMSSMT)</td>\n<td><a href=\"https://csrc.nist.gov/pubs/sp/800/208/final\" target=\"_blank\">NISTSP 800-208</a></td>\n</tr>\n</tbody>\n</table>\n<h2><strong>Product Lists</strong></h2>\n<p><a href=\"#Table2\">Table 2</a> details widely available categories with respective types of hardware and software products that use PQC standards to protect sensitive information well into the foreseeable future, including after the advent of a cryptographically relevant quantum computer (CRQC). Organizations building PQC migration plans can use these categories as a guide to assess future technological needs. Once a category is listed as having PQC-capable products widely available, organizations should plan acquisitions to procure only PQC-capable products in that category.<a href=\"#Note4\"><sup>4</sup></a>&nbsp;</p>\n<p><a href=\"#Table3\">Table 3</a> does not list categories of PQC-capable products that are currently widely available; instead, it lists product categories where manufacturer implementation and testing of PQC capabilities are encouraged. It is important that&nbsp;the products listed in <a href=\"#Table3\">Table 3</a> implement PQC for core features and for all secondary functionality, such as for software updates.&nbsp;As the <a href=\"#Table3\">Table 3</a> product categories mature their capabilities and transition to PQC, CISA will move them from <a href=\"#Table3\">Table 3</a> to the list in <a href=\"#Table2\">Table 2</a>.</p>\n<p><a href=\"#Table2\">Tables 2</a> and <a href=\"#Table3\">3</a> consider efforts within the General Services Administration (GSA),<a href=\"#Note5\"><sup>5</sup></a><sup>,</sup><a href=\"#Note6\"><sup>6</sup></a> CISA,<a href=\"#Note7\"><sup>7</sup></a> NIST,<a href=\"#Note8\"><sup>8</sup></a> and the National Security Agency (NSA)<a href=\"#Note9\"><sup>9</sup></a>. &nbsp;<strong>Note: </strong><a href=\"#Table2\">Tables 2</a> and <a href=\"#Table3\">3</a> are not exhaustive lists; CISA will periodically update these tables as needed to cover new examples of widely available products that use PQC standards.</p>\n<p><a class=\"ck-anchor\" id=\"Table2\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 2: Widely Available Hardware and Software Product Categories That Use PQC Standards</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\"><strong>Product Category*</strong></p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Example Product Type</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Cloud Services</td>\n<td>Platform-as-a-service (PaaS), infrastructure-as-a-service (IaaS)&nbsp;</td>\n</tr>\n<tr>\n<td>Collaboration Software</td>\n<td>Chat/messaging</td>\n</tr>\n<tr>\n<td>Web Software</td>\n<td>Web browsers, web servers</td>\n</tr>\n<tr>\n<td>Endpoint Security<a href=\"#Note10\"><sup>10</sup></a></td>\n<td>Data at rest (DAR) security, full disk encryption</td>\n</tr>\n</tbody>\n</table>\n<p><strong>*&nbsp;</strong>Most of these categories have implemented&nbsp;PQC for key encapsulation and key agreement but have not yet widely implemented PQC for digital signatures and authentication. As a result, these categories are not considered to be <em>fully</em> quantum resistant; CISA includes them on this list because one of their main security services is quantum resistant and Federal Civilian Executive Branch (FCEB) departments and agencies should procure them appropriately.&nbsp;</p>\n<p><a class=\"ck-anchor\" id=\"Table3\"></a></p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><em>Table 3: Hardware and Software Product Categories Transitioning to Use PQC Standards</em></caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">\n<p class=\"text-align-center\"><strong>Product Category</strong></p>\n</th>\n<th role=\"columnheader\">\n<p class=\"text-align-center\"><strong>Example Product Type</strong></p>\n</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Networking Hardware</td>\n<td>Proxy servers, routers, firewalls, switches, appliances</td>\n</tr>\n<tr>\n<td>Networking Software</td>\n<td>Software-defined network (SDN), domain name service (DNS), network operating systems</td>\n</tr>\n<tr>\n<td>Cloud Services</td>\n<td>Software-as-a-service (SaaS)</td>\n</tr>\n<tr>\n<td>Telecommunications Hardware</td>\n<td>Desk phones, fax machine, voice over IP (VoIP), radio</td>\n</tr>\n<tr>\n<td>Computers (Physical and Virtual)</td>\n<td>Operating systems, hypervisors, containers</td>\n</tr>\n<tr>\n<td>Computer Peripherals</td>\n<td>Wireless keyboards, wireless headsets</td>\n</tr>\n<tr>\n<td>Storage Area Network</td>\n<td>Appliances, operating systems, applications</td>\n</tr>\n<tr>\n<td>Identity, Credential, and Access Management (ICAM) Software</td>\n<td>Identity management systems, identity provider and federation services, certificate authorities, access brokers, access management software, public key infrastructure (PKI) management software&nbsp;</td>\n</tr>\n<tr>\n<td>Identity, Credential, and Access Management (ICAM) Hardware</td>\n<td>Hardware security modules (HSM), authentication tokens, badges/cards, badge/card readers</td>\n</tr>\n<tr>\n<td>Collaboration Software</td>\n<td>Email clients, email servers, conferencing, file sharing</td>\n</tr>\n<tr>\n<td>Data</td>\n<td>Database, Structured Query Language (SQL) server&nbsp;</td>\n</tr>\n<tr>\n<td>Endpoint Security</td>\n<td>Password managers, antivirus/anti-malware software, asset management</td>\n</tr>\n<tr>\n<td>Enterprise Security</td>\n<td>Continuous diagnostics and mitigation (CDM) tools, intrusion detection/monitoring, inspection systems, security information, and event monitoring (SIEM)</td>\n</tr>\n</tbody>\n</table>\n<p><strong>Note:&nbsp;</strong>The above lists<strong>&nbsp;</strong>exclude categories of hardware and software products, such as operational technology (OT) and internet of things (IoT) devices, that are not considered traditional IT products. These also should be transitioning to PQC standards as well but are out of scope for these lists.</p>\n<h2><strong>Notes&nbsp;</strong></h2>\n<ol>\n<li><a class=\"ck-anchor\" id=\"Note1\"></a>Per EO 14306, \u201cthe Secretary of Homeland Security, acting through the Director of the Cybersecurity and Infrastructure Security Agency (CISA), and in consultation with the Director of the National Security Agency, shall release and thereafter regularly update a list of product categories in which products that support post-quantum cryptography (PQC) are widely available.\u201d</li>\n<li><a class=\"ck-anchor\" id=\"Note2\"></a><a href=\"https://csrc.nist.rip/glossary/term/key_establishment\" target=\"_blank\">https://csrc.nist.rip/glossary/term/key_establishment</a></li>\n<li><a class=\"ck-anchor\" id=\"Note3\"></a><a href=\"https://csrc.nist.rip/glossary/term/digital_signature\" target=\"_blank\">https://csrc.nist.rip/glossary/term/digital_signature</a></li>\n<li><a class=\"ck-anchor\" id=\"Note4\"></a>Even once a product that supports PQC standards is procured, it may need to use non-PQC algorithms for a time for interoperability reasons.</li>\n<li><a class=\"ck-anchor\" id=\"Note5\"></a><a href=\"https://buy.gsa.gov/api/system/files/documents/final-508c-pqc_buyer-s_guide_2025.pdf\" target=\"_blank\">https://buy.gsa.gov/api/system/files/documents/final-508c-pqc_buyer-s_guide_2025.pdf</a></li>\n<li><a class=\"ck-anchor\" id=\"Note6\"></a><a href=\"https://www.gsa.gov/technology/it-contract-vehicles-and-purchasing-programs/multiple-award-schedule-it\" target=\"_blank\">https://www.gsa.gov/technology/it-contract-vehicles-and-purchasing-programs/multiple-award-schedule-it</a></li>\n<li><a class=\"ck-anchor\" id=\"Note7\"></a><a href=\"https://www.cisa.gov/sites/default/files/cdm_files/HWAMInitializationGuide.pdf\">https://www.cisa.gov/sites/default/files/cdm_files/HWAMInitializationGuide.pdf</a></li>\n<li><a class=\"ck-anchor\" id=\"Note8\"></a><a href=\"https://www.nist.gov/itl/executive-order-improving-nations-cybersecurity/critical-software-definition-explanatory\" target=\"_blank\">https://www.nist.gov/itl/executive-order-improving-nations-cybersecurity/critical-software-definition-explanatory</a></li>\n<li><a class=\"ck-anchor\" id=\"Note9\"></a><a href=\"https://www.niap-ccevs.org/products\" target=\"_blank\">https://www.niap-ccevs.org/products</a></li>\n<li><a class=\"ck-anchor\" id=\"Note10\"></a>The principal security service of the Endpoint Security category is not naturally quantum vulnerable. When procuring, one needs to ensure that other relevant features of the product, such as firmware updates, are utilizing post-quantum cryptography (PQC).</li>\n</ol>\n<p>&nbsp;</p>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.&nbsp;</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/product-categories-technologies-use-post-quantum-cryptography-standards\" data-entity-type=\"external\">CISA Product Survey</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Fri, 23 Jan 26 12:00:00 +0000",
        "last_updated": "Fri, 23 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/23/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/23/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>Known Exploited Vulnerabilities (KEV) Catalog</u></a>, based on evidence of active exploitation.&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW240314876 BCX8\">\n<ul>\n<li><a class=\"Hyperlink SCXW240314876 BCX8\" href=\"https://www.cve.org/CVERecord?id=CVE-2024-37079\" target=\"_blank\" rel=\"noreferrer noopener\"><u>CVE-2024-37079</u></a> Broadcom VMware vCenter Server Out-of-bounds Write Vulnerability&nbsp;</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\"><u>Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</u></a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\"><u>BOD 22-01 Fact Sheet</u></a> for more information.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW240314876 BCX8\">\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Fri, 23 Jan 26 12:00:00 +0000",
        "last_updated": "Fri, 23 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-07",
        "title": "Delta Electronics DIAView",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could enable an attacker to execute arbitrary code.</strong></p>\n<p>The following versions of Delta Electronics DIAView are affected:</p>\n<ul>\n<li>DIAView (CVE-2026-0975)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Delta Electronics</td>\n<td>Delta Electronics DIAView</td>\n<td>Improper Neutralization of Special Elements used in a Command ('Command Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0975</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>DIAView functions can execute shell commands within a project script. If an attacker tricks the victim into running a project containing a malicious script, then arbitrary code can be executed when the malicious project starts.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-0975\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics DIAView</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics DIAView: 4.2.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Delta Electronics recommends users update to DIAView v4.4 or later.</p>\n<p><strong>Mitigation</strong><br>For more information, see Delta Electronics advisory Delta-PCSA-2026-00002.</p>\n<p><strong>Mitigation</strong><br>Delta Electronics offers users the following general recommendations:</p>\n<p><strong>Mitigation</strong><br>Do not click on untrusted Internet links or open unsolicited attachments in emails.</p>\n<p><strong>Mitigation</strong><br>Avoid exposing control systems and equipment to the Internet.</p>\n<p><strong>Mitigation</strong><br>Place control system networks and remote devices behind firewalls, and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use a secure access method, such as a virtual private network (VPN).</p>\n<p><strong>Mitigation</strong><br>If you have any product-related support concerns, contact Delta via the portal page for any information or materials you may require.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/77.html\">CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous researcher at Trend Zero Day Initiative reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-08",
        "title": "EVMAPA",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could lead to degraded service, a denial-of-service, or unauthorized remote command execution, which could lead to spoofing or a manipulation of charging station statuses.</strong></p>\n<p>The following versions of EVMAPA are affected:</p>\n<ul>\n<li>EVMAPA (CVE-2025-54816, CVE-2025-53968, CVE-2025-55705)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>EVMAPA</td>\n<td>EVMAPA</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Czechia, Slovakia</li>\n<li><strong>Company Headquarters Location: </strong>Czechia</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-54816</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability occurs when a WebSocket endpoint does not enforce proper authentication mechanisms, allowing unauthorized users to establish connections. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-54816\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-54816: EVMAPA informed CISA some of their charging stations do not allow changes to the authorization key using the Open Charge Point Protocol (OCPP). Currently, charge point operators have the option to connect stations using WebSocket Secure (WSS), and EVMAPA connects stations they supply via their own VPN. For OCPP 2.x and newer stations, EVMAPA plans to implement BASIC authorization control.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-53968</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability arises because there are no limitations on the number of authentication attempts a user can make. An attacker can exploit this weakness by continuously sending authentication requests, leading to a denial-of-service (DoS) condition. This can overwhelm the authentication system, rendering it unavailable to legitimate users and potentially causing service disruption. This can also allow attackers to conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-53968\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-53968: EVMAPA did not release a statement regarding this vulnerability. Contact EVMAPA directly for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-55705</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability occurs when the system permits multiple simultaneous connections to the backend using the same charging station ID. This can result in unauthorized access, data inconsistency, or potential manipulation of charging sessions. The lack of proper session management and expiration control allows attackers to exploit this weakness by reusing valid charging station IDs to establish multiple sessions concurrently.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-55705\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVMAPA</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVMAPA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVMAPA EVMAPA: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CVE-2025-55705: EVMAPA informed CISA they have resolved this issue and do not allow simultaneous connection of charging stations with the same CBID.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine reported these vulnerabilities to CISA</li>\n<li>Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/01/22/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Four Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/01/22/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added four new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-31125\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-31125</a> Vite Vitejs Improper Access Control Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34026\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-34026</a> Versa Concerto Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-54313\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-54313</a> Prettier eslint-config-prettier Embedded Malicious Code Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-68645\" target=\"_blank\" data-entity-type=\"external\">CVE-2025-68645</a> Synacor Zimbra Collaboration Suite (ZCS) PHP Remote File Inclusion Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-06",
        "title": "Hubitat Elevation Hubs",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an authenticated attacker to escalate their privileges and control devices outside of their authorized scope.</strong></p>\n<p>The following versions of Hubitat Elevation Hubs are affected:</p>\n<ul>\n<li>Elevation C3 (CVE-2026-1201)</li>\n<li>Elevation C4 (CVE-2026-1201)</li>\n<li>Elevation C5 (CVE-2026-1201)</li>\n<li>Elevation C7 (CVE-2026-1201)</li>\n<li>Elevation C8 (CVE-2026-1201)</li>\n<li>Elevation C8 pro (CVE-2026-1201)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Hubitat</td>\n<td>Hubitat Elevation Hubs</td>\n<td>Authorization Bypass Through User-Controlled Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1201</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Authorization Bypass Through User-Controlled Key vulnerability in Hubitat Elevation home automation controllers prior to version 2.4.2.157 could allow a remote authenticated user to control connected devices outside of their authorized scope via client-side request manipulation.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-1201\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hubitat Elevation Hubs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hubitat</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Hubitat Elevation C3: &lt;firmware_2.4.2.157, Hubitat Elevation C4: &lt;firmware_2.4.2.157, Hubitat Elevation C5: &lt;firmware_2.4.2.157, Hubitat Elevation C7: &lt;firmware_2.4.2.157, Hubitat Elevation C8: &lt;firmware_2.4.2.157, Hubitat Elevation C8 pro: &lt;firmware_2.4.2.157</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Hubitat has released the following for users to implement:</p>\n<p><strong>Mitigation</strong><br>Firmware version 2.4.2.157</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Aaron 'theHastyOne' Hasty of Ostrich Lab reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-22</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-22</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 22 Jan 26 12:00:00 +0000",
        "last_updated": "Thu, 22 Jan 26 12:00:00 +0000"
    }
]