· CISA Cybersecurity Advisory

Chargemap chargemap.com

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment Vulnerabilities v3 9.4 Chargemap Chargemap chargemap.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-25851 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-20792 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or misrouting legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25711 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-20791 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Yokogawa CENTUM VP R6, R7

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to terminate the software stack process, cause a denial-of-service condition, or execute arbitrary code. The following versions of Yokogawa CENTUM VP R6, R7 are affected: Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to terminate the software stack process, cause a denial-of-service condition, or execute arbitrary code. The following versions of Yokogawa CENTUM VP R6, R7 are affected: Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022, CVE-2025-48023) Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022, CVE-2025-48023) CVSS Vendor Equipment Vulnerabilities v3 6.9 Yokogawa Yokogawa CENTUM VP R6, R7 Out-of-bounds Write, Reachable Assertion, Integer Underflow (Wrap or Wraparound), Improper Handling of Length Parameter Inconsistency Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-1924 If the affected product receives maliciously crafted packets, a DoS attack may cause Vnet/IP communication functions to stop or arbitrary programs to be executed. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.9 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:H CVE-2025-48019 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48020 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48021 If theaffected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-191 Integer Underflow (Wrap or Wraparound) Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48022 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48023 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Dmitry Sklyar and Demid Uzenkov of Positive Technologies reported these vulnerabilities to Yokogawa Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. These vulnerabilities have a high attack complexity. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Republication of YSAR-26-0002 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Pelco, Inc. Sarix Pro 3 Series IP Cameras

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized access to sensitive device data, bypass surveillance controls, and expose facilities to privacy breaches, operational risks, and regulatory compliance issues. The following versions of Pelco, Inc. Sarix Pro 3 Series IP Cameras are affected: Sarix Professional IMP 3 Series <=02.52 (CVE-2026-1241) Sarix…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized access to sensitive device data, bypass surveillance controls, and expose facilities to privacy breaches, operational risks, and regulatory compliance issues. The following versions of Pelco, Inc. Sarix Pro 3 Series IP Cameras are affected: Sarix Professional IMP 3 Series <=02.52 (CVE-2026-1241) Sarix Professional IXP 3 Series <=02.52 (CVE-2026-1241) Sarix Professional IBP 3 Series <=02.52 (CVE-2026-1241) Sarix Professional IWP 3 Series <=02.52 (CVE-2026-1241) CVSS Vendor Equipment Vulnerabilities v3 7.5 Pelco, Inc. Pelco, Inc. Sarix Pro 3 Series IP Cameras Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Commercial Facilities, Defense Industrial Base, Energy, Government Services and Facilities, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1241 The Pelco, Inc. Sarix Professional 3 Series Cameras are vulnerable to an authentication bypass issue in their web management interface. The flaw stems from inadequate enforcement of access controls, allowing certain functionality to be accessed without proper authentication. This weakness can lead to unauthorized viewing of live video streams, creating privacy concerns and operational risks for organizations relying on these cameras. Additionally, it may expose operators to regulatory and compliance challenges. View CVE Details Affected Products Pelco, Inc. Sarix Pro 3 Series IP Cameras Vendor: Pelco, Inc. Product Version: Pelco, Inc. Sarix Professional IMP 3 Series: <=02.52, Pelco, Inc. Sarix Professional IXP 3 Series: <=02.52, Pelco, Inc. Sarix Professional IBP 3 Series: <=02.52, Pelco, Inc. Sarix Professional IWP 3 Series: <=02.52 Product Status: known_affected Remediations Mitigation Pelco, Inc. recommends that all Sarix Professional 3 Series Camera users update their camera firmware to version 02.53 or later. Installing the latest firmware ensures your device receives the most up-to-date bug fixes and critical security enhancements. Mitigation More information can be found by visiting Pelco, Inc's technical support page (https://www.pelco.com/support) for assistance. Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Copeland XWEB and XWEB Pro

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication, cause a denial-of-service condition, cause memory corruption, and execute arbitrary code. The following versions of Copeland XWEB and XWEB Pro are affected: XWEB 300D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication, cause a denial-of-service condition, cause memory corruption, and execute arbitrary code. The following versions of Copeland XWEB and XWEB Pro are affected: XWEB 300D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) XWEB 500D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) XWEB 500B PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) CVSS Vendor Equipment Vulnerabilities v3 10 Copeland Copeland XWEB and XWEB Pro Unexpected Status Code or Return Value, Use of a Broken or Risky Cryptographic Algorithm, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-25085 A vulnerability exists in Copeland XWEB Pro version 1.12.1 and prior, in which an unexpected return value from the authentication routine is later on processed as a legitimate value, resulting in an authentication bypass. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-394 Unexpected Status Code or Return Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L CVE-2026-21718 An authentication bypass vulnerability exists in Copeland XWEB Pro version 1.12.1 and prior, enabling any attackers to bypass the authentication requirement and achieve pre-authenticated code execution on the system. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-24663 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an unauthenticated attacker to achieve remote code execution on the system by sending a crafted request to the libraries installation route and injecting malicious input into the request body. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-21389 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the request body sent to the contacts import route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25111 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the restore route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20742 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the templates route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24517 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the firmware update route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25195 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by supplying a crafted firmware update file via the firmware update route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20910 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field of the firmware update update action to achieve remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24689 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field of the firmware update apply action. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25109 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field when accessing the get setup route, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20902 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the map filename field during the map upload action of the parameters route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24695 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into OpenSSL argument fields within requests sent to the utility route, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25105 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into parameters of the Modbus command tool in the debug route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24452 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by supplying a crafted template file to the devices route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-23702 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by sending malicious input injected into the server username field of the import preconfiguration action in the API V1 route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25721 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the server username and/or password fields of the restore action in the API V1 route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20764 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by providing malicious input via the device hostname configuration which is later processed during system setup, resulting in remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25196 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the Wi-Fi SSID and/or password fields can lead to remote code execution when the configuration is processed. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25037 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by configuring a maliciously crafted LCD state which is later processed during system setup, enabling remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-22877 An arbitrary file-read vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling unauthenticated attackers to read arbitrary files on the system, and potentially causing a denial-of-service attack. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-20797 A stack based buffer overflow exists in an API route of XWEB Pro version 1.12.1 and prior, enabling unauthenticated attackers to cause stack corruption and a termination of the program. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L CVE-2026-3037 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by modifying malicious input injected into the MBird SMS service URL and/or code via the utility route which is later processed during system setup, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Acknowledgments Amir Zaltzman and Noam Moshe of Claroty Team82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EV Energy ev.energy

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EV Energy ev.energy are affected: ev.energy vers:all/* (CVE-2026-27772, CVE-2026-24445, CVE-2026-26290, CVE-2026-25774) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EV Energy ev.energy are affected: ev.energy vers:all/* (CVE-2026-27772, CVE-2026-24445, CVE-2026-26290, CVE-2026-25774) CVSS Vendor Equipment Vulnerabilities v3 9.4 EV Energy EV Energy ev.energy Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-27772 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-24445 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-26290 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-25774 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mobility46 mobility46.se

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment Vulnerabilities v3 9.4 Mobility46 Mobility46 mobility46.se Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-27028 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-26305 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27647 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-22878 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CloudCharge cloudcharge.se

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of CloudCharge cloudcharge.se are affected: cloudcharge.se vers:all/* (CVE-2026-20781, CVE-2026-25114, CVE-2026-27652, CVE-2026-20733)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of CloudCharge cloudcharge.se are affected: cloudcharge.se vers:all/* (CVE-2026-20781, CVE-2026-25114, CVE-2026-27652, CVE-2026-20733) CVSS Vendor Equipment Vulnerabilities v3 9.4 CloudCharge CloudCharge cloudcharge.se Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-20781 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25114 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27652 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-20733 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EV2GO ev2go.io

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of EV2GO ev2go.io are affected: ev2go.io vers:all/* (CVE-2026-24731, CVE-2026-25945, CVE-2026-20895, CVE-2026-22890) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of EV2GO ev2go.io are affected: ev2go.io vers:all/* (CVE-2026-24731, CVE-2026-25945, CVE-2026-20895, CVE-2026-22890) CVSS Vendor Equipment Vulnerabilities v3 9.4 EV2GO EV2GO ev2go.io Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-24731 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25945 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-20895 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-22890 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SWITCH EV swtchenergy.com

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773) CVSS Vendor Equipment Vulnerabilities v3 9.4 SWITCH EV SWITCH EV swtchenergy.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-27767 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25113 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25778 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27773 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls, Inc. Frick Controls Quantum HD

View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities v3 9.1 Johnson Controls, Inc. Johnson Controls, Inc. Frick Controls Quantum HD Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Control of Generation of Code ('Code Injection'), Relative Path Traversal, Plaintext Storage of a Password Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21654 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21656 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21657 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21658 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21659 The Frick Controls Quantum HD contains a vulnerability that allows an unauthenticated attacker to execute arbitrary code on the affected device, leading to full system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-21660 Hardcoded credentials in the Frick Controls Quantum HD create a vulnerability that leads to unauthorized access, exposure of sensitive information, and potential misuse or system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-256 Plaintext Storage of a Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.2 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Noam Moshe of Claroty Research Team 82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA and Partners Release Guidance for Ongoing Global Exploitation of Cisco SD-WAN Systems

The purpose of this Alert is to provide resources for organizations with Cisco Software-Defined Wide-Area Networking (SD-WAN) systems, including Federal Civilian Executive Branch (FCEB) agencies, to address ongoing exploitation of multiple vulnerabilities. Notably, the Cybersecurity and Infrastructure Security Agency (CISA) has added CVE-2026-20127 and CVE-2022-20775 to its Known Exploited Vulnerabilities (KEV)…
Read full source summary
The purpose of this Alert is to provide resources for organizations with Cisco Software-Defined Wide-Area Networking (SD-WAN) systems, including Federal Civilian Executive Branch (FCEB) agencies, to address ongoing exploitation of multiple vulnerabilities. Notably, the Cybersecurity and Infrastructure Security Agency (CISA) has added CVE-2026-20127 and CVE-2022-20775 to its Known Exploited Vulnerabilities (KEV) Catalog on Feb. 25, 2026. As a result of the malicious cyber activity and vulnerabilities involving Cisco SD-WAN systems, CISA has outlined requirements for FCEB agencies in Emergency Directive (ED) 26-03 to inventory Cisco SD-WAN systems, update them, and assess compromise. CISA and partners have observed malicious cyber actors targeting and compromising Cisco SD-WAN systems of organizations, globally. These actors have been observed exploiting a previously undisclosed authentication bypass vulnerability, CVE-2026-20127, for initial access before escalating privileges using CVE-2022-20775 and establishing long-term persistence in Cisco SD-WAN systems. CISA, National Security Agency (NSA), and international partners Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC), Canadian Centre for Cyber Security (Cyber Centre), New Zealand National Cyber Security Centre (NCSC-NZ), and United Kingdom National Cyber Security Centre (NCSC-UK), hereafter the “authoring organizations,” strongly urge network defenders to immediately 1) inventory all in-scope Cisco SD-WAN systems, 2) collect artifacts, including virtual snapshots and logs off of SD-WAN systems to support threat hunt activities, 3) fully patch Cisco SD-WAN systems with available updates, 4) hunt for evidence of compromise, and 5) concurrently review Cisco’s latest security advisories, Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability and Cisco Catalyst SD-WAN Vulnerabilities, and implement Cisco’s SD-WAN Hardening Guidance.1 To address malicious activity involving vulnerable Cisco SD-WAN systems, CISA issued Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems, which outlines requirements for FCEB agencies to inventory Cisco SD-WAN systems, update them, and assess compromise. Further, CISA released Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems to provide prescriptive actions for FCEB agencies. Cisco’s Catalyst SD-WAN Hardening Guide recommends that network defenders address: Network perimeter controls: Ensure control components are behind a firewall, isolate virtual private network (VPN) 512 interfaces, and use internet protocol (IP) blocks for manually provisioned edge IPs. SD-WAN manager access: Replace the self-signed certificate for the web user interface. Control and data plane security: Use pairwise keys. Session timeout: Limit to the shortest period possible. Logging: Forward to a remote syslog server. CISA and the authoring organizations are providing the following resources: CISA: Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems CISA: Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems Cisco: Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability Cisco: Cisco Catalyst SD-WAN Vulnerabilities Cisco: Cisco Catalyst SD-WAN Hardening Guide ASD’s ACSC: Cisco SD-WAN Threat Hunt Guide, co-sealed by CISA, NSA, Cyber Centre, NCSC-NZ, and NCSC-UK. This guide, based on investigative data, supports network defenders’ detection of and response to the malicious actors’ threat activity Acknowledgements NSA, ASD’s ACSC, Cyber Centre, NCSC-NZ, and NCSC-UK contributed to this alert. Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Notes 1 Cisco Security, “Cisco Catalyst SD-WAN Hardening Guide,” last modified February 9, 2026, https://sec.cloudapps.cisco.com/security/center/resources/Cisco-Catalyst-SD-WAN-HardeningGuide
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2022-20775 Cisco Catalyst SD-WAN Path Traversal Vulnerability CVE-2026-20127 Cisco Catalyst SD-WAN Controller and Manager Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2022-20775 Cisco Catalyst SD-WAN Path Traversal Vulnerability CVE-2026-20127 Cisco Catalyst SD-WAN Controller and Manager Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Gardyn Home Kit

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control edge devices, access cloud-based devices and user information without authentication, and pivot to other edge devices managed in the Gardyn cloud environment. The following versions of Gardyn Home Kit are affected: Home Kit Firmware Gardyn Home Kit Mobile Application <2.11.0 (CVE-2025-29628,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control edge devices, access cloud-based devices and user information without authentication, and pivot to other edge devices managed in the Gardyn cloud environment. The following versions of Gardyn Home Kit are affected: Home Kit Firmware Gardyn Home Kit Mobile Application <2.11.0 (CVE-2025-29628, CVE-2025-29629, CVE-2025-29631, CVE-2025-1242) Gardyn Home Kit Cloud API <2.12.2026 (CVE-2025-29628, CVE-2025-29629, CVE-2025-29631, CVE-2025-1242) CVSS Vendor Equipment Vulnerabilities v3 9.1 Gardyn Gardyn Home Kit Cleartext Transmission of Sensitive Information, Use of Default Credentials, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-29628 A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2025-29629 The Gardyn Home Kit uses weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-1392 Use of Default Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2025-29631 The Gardyn Home Kit is vulnerable to command injection through vulnerable methods that do not sanitize input before passing content to the operating system for execution. The vulnerability may allow an attacker to execute arbitrary operating system commands on a target Home Kit. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation For CVE-2025-29631: Gardyn is currently working on a full mitigation to address this vulnerability. As previously stated, Gardyn recommends that users ensure their devices are always updated to the most current firmware version. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2025-1242 The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments Michael Groberman reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-24 Date Revision Summary 2026-02-24 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Building Operation Workstation

View CSAF Summary Schneider Electric is aware of a vulnerability in EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation. [EcoStruxure Building Operation (EBO)](https://www.se.com/ww/en/product-range/62111-ecostruxure-building-operation-software/#overview) is an open and scalable software platform providing insight, control and management of multiple building systems and devices…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation. [EcoStruxure Building Operation (EBO)](https://www.se.com/ww/en/product-range/62111-ecostruxure-building-operation-software/#overview) is an open and scalable software platform providing insight, control and management of multiple building systems and devices in one mobile-enabled convenient view. It delivers valuable data for decision-making to improve energy management and increase efficiency for better building performance and comfort, reduced carbon, and more sustainable building environments. Failure to apply the remediations below may risk exposure of local files or denial of service, which could result in data breaches, and operational disruptions. The following versions of Schneider Electric EcoStruxure Building Operation Workstation are affected: EcoStruxure Building Operation Workstation vers:generic/>=7.0.x|<7.0.3.2000_(CP1), 7.0.3.2000_CP1, vers:generic/>=6.x|<6.0.4.14001_(CP10), 6.0.4.14001_CP10, vers:intdot/>=7.0.x|<7.0.2, 7.0.2, vers:generic/>=6.0.x|<6.0.4.7000_(CP5), 6.0.4.7000_CP5 (CVE-2026-1227, CVE-2026-1227, CVE-2026-1226, CVE-2026-1226) EcoStruxure Building Operation WebStation vers:generic/>=7.0.x|<7.0.3.2000_(CP1), 7.0.3.2000_CP1, vers:generic/>=6.x|<6.0.4.14001_(CP10), 6.0.4.14001_CP10, vers:intdot/>=7.0.x|<7.0.2, 7.0.2, vers:generic/>=6.0.x|<6.0.4.7000_(CP5), 6.0.4.7000_CP5 (CVE-2026-1227, CVE-2026-1227, CVE-2026-1226, CVE-2026-1226) CVSS Vendor Equipment Vulnerabilities v3 7.3 Schneider Electric Schneider Electric EcoStruxure Building Operation Workstation Improper Restriction of XML External Entity Reference, Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Energy, Government Services and Facilities, Healthcare and Public Health, Information Technology, Transportation Systems, Financial Services, Defense Industrial Base, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-1227 An improper restriction of XML external entity reference vulnerability exists that could result in unauthorized disclosure of local files, unauthorized interaction with the EBO system, or denial-of-service conditions. This occurs when a local user uploads a maliciously crafted TGML graphics file to the EBO server from Workstation. View CVE Details Affected Products Schneider Electric EcoStruxure Building Operation Workstation Vendor: Schneider Electric Product Version: EcoStruxure Building Operation Workstation All 7.0.x versions prior to 7.0.3.2000 (CP1), EcoStruxure Building Operation Workstation All 6.x versions prior to 6.0.4.14001 (CP10), EcoStruxure Building Operation WebStation All 7.0.x versions prior to 7.0.3.2000 (CP1), EcoStruxure Building Operation WebStation All 6.x versions prior to 6.0.4.14001 (CP10) Product Status: fixed, known_affected Remediations Vendor fix The following versions of EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation include a fix for CVE-2026-1227: • 7.0.3.2000 (CP1) Step 1: Navigate to this link: https://www.se.com/myschneider/documentsDownloadCenter/detail?id=EBO-Patch-v7-0 Step 2: Download 'EcoStruxure Building Operation Patch v7.0' Step 3: Follow the installation instructions provided in the accompanying readme file. Additionally, ensure you are following the [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Vendor fix The following versions of EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation includes a fix for CVE-2026-1227: • 6.0.4.14001 (CP10) Step 1: Locate the appropriate version for your system here: https://www.se.com/myschneider/documentsDownloadCenter/detail?id=EBO-Patch-v6-0 Step 2: Download ‘EcoStruxure Building Operation Patch v6.0‘ Step 3: Follow the installation instructions provided in the accompanying readme file. Additionally, ensure you are following the [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Implement strong access controls to limit system access to authorized personnel. • Use multi factor authentication if using EBO version 7.0 or later. • Use firewalls to segregate networks and protect the building management system. • Regularly monitor system activity. • Ensure you are following [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Mitigation For more information see the associated Schneider Electric security advisory SEVD-2026-041-02, titled ‘Multiple Vulnerabilities on EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation‘. • PDF Version: [https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-02.pdf](https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-02.pdf) • CSAF Version: [https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-041-02.json](https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-041-02.json). Relevant CWE: CWE-611 Improper Restriction of XML External Entity Reference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2026-1226 An improper control of generation of code vulnerability exists that could result in the execution of untrusted or unintended code within the application. This occurs when maliciously crafted design content is processed through a TGML graphics file. View CVE Details Affected Products Schneider Electric EcoStruxure Building Operation Workstation Vendor: Schneider Electric Product Version: EcoStruxure Building Operation Workstation All 7.0.x versions prior to 7.0.2, EcoStruxure Building Operation Workstation All 6.0.x versions prior to 6.0.4.7000 (CP5), EcoStruxure Building Operation Webstation All 7.0.x versions prior to 7.0.2, EcoStruxure Building Operation Webstation All 6.0.x versions prior to 6.0.4.7000 (CP5) Product Status: fixed, known_affected Remediations Vendor fix The following versions of EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation include a fix for CVE-2026-1226: • 7.0.2 Step 1: Navigate to this link: https://www.se.com/myschneider/documentsDownloadCenter/detail?id=EBO-Patch-v7-0 Step 2: Download 'EcoStruxure Building Operation Patch v7.0' Step 3: Follow the installation instructions provided in the accompanying readme file. Additionally, ensure you are following the [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Vendor fix The following versions of EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation includes a fix for CVE-2026-1226: • 6.0.4.7000 (CP5) Step 1: Locate the appropriate version for your system here: https://www.se.com/myschneider/documentsDownloadCenter/detail?id=EBO-Patch-v6-0 Step 2: Download ‘EcoStruxure Building Operation Patch v6.0‘ Step 3: Follow the installation instructions provided in the accompanying readme file. Additionally, ensure you are following the [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Implement strong access controls to limit system access to authorized personnel. • Use multi factor authentication if using EBO version 7.0 or later. • Use firewalls to segregate networks and protect the building management system. • Regularly monitor system activity. • Ensure you are following [EBO hardening guidelines](https://ecostruxure-building-help.se.com/bms/Topics/show.castle?id=14923&productversion=7.1&locale=en-US). Mitigation For more information see the associated Schneider Electric security advisory SEVD-2026-041-02, titled "Multiple Vulnerabilities on EcoStruxure Building Operation Workstation and EcoStruxure Building Operation WebStation". • PDF Version: [https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-02.pdf](https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-02.pdf) • CSAF Version: [https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-041-02.json](https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-041-02.json). Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H Acknowledgments Pentest Limited reported these vulnerabilities to Schneider Electric. Robin Plugge reported these vulnerabilities to Schneider Electric. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability: * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. * Locate control system networks and remote devices behind firewalls and isolate them from business networks. * When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. (https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf) CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. (https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf) Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric SEVD-2026-041-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-10 Date Revision Summary 2026-02-10 1 Original Release 2026-02-24 2 Initial CISA Republication of Schneider Electric SEVD-2026-041-02 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25108 Soliton Systems K.K. FileZen OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25108 Soliton Systems K.K. FileZen OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

InSAT MasterSCADA BUK-TS

View CSAF Summary Successful exploitation of these vulnerabilities may allow remote code execution. The following versions of InSAT MasterSCADA BUK-TS are affected: MasterSCADA BUK-TS vers:all/* (CVE-2026-21410, CVE-2026-22553) CVSS Vendor Equipment Vulnerabilities v3 9.8 InSAT InSAT MasterSCADA BUK-TS Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Neutralization of…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities may allow remote code execution. The following versions of InSAT MasterSCADA BUK-TS are affected: MasterSCADA BUK-TS vers:all/* (CVE-2026-21410, CVE-2026-22553) CVSS Vendor Equipment Vulnerabilities v3 9.8 InSAT InSAT MasterSCADA BUK-TS Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Russia Vulnerabilities Expand All + CVE-2026-21410 InSAT MasterSCADA BUK-TS is susceptible to SQL Injection through its main web interface. Malicious users that use the vulnerable endpoint are potentially able to cause remote code execution. View CVE Details Affected Products InSAT MasterSCADA BUK-TS Vendor: InSAT Product Version: InSAT MasterSCADA BUK-TS: vers:all/* Product Status: known_affected Remediations Mitigation InSAT has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact info@insat.ru or scada@insat.ru for additional information. Mitigation InSAT has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact info@insat.ru or scada@insat.ru for additional information. Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-22553 All versions of InSAT MasterSCADA BUK-TS are susceptible to OS command injection through a field in its MMadmServ web interface. Malicious users that use the vulnerable endpoint are potentially able to cause remote code execution. View CVE Details Affected Products InSAT MasterSCADA BUK-TS Vendor: InSAT Product Version: InSAT MasterSCADA BUK-TS: vers:all/* Product Status: known_affected Remediations Mitigation InSAT has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact info@insat.ru or scada@insat.ru for additional information. Mitigation InSAT has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact info@insat.ru or scada@insat.ru for additional information. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Adem El Adeb reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-24 Date Revision Summary 2026-02-24 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-49113 RoundCube Webmail Deserialization of Untrusted Data Vulnerability CVE-2025-68461 RoundCube Webmail Cross-site Scripting Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-49113 RoundCube Webmail Deserialization of Untrusted Data Vulnerability CVE-2025-68461 RoundCube Webmail Cross-site Scripting Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller

View CSAF Summary Successful exploitation of this vulnerability could result in an over- or under-odorization event. The following versions of Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller are affected: OdorEyes EcoSystem Pulse Bypass System with XL4 Controller vers:all/* (CVE-2026-24790) CVSS Vendor Equipment Vulnerabilities v3 8.2 Welker Welker OdorEyes EcoSystem Pulse Bypass System with XL4…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an over- or under-odorization event. The following versions of Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller are affected: OdorEyes EcoSystem Pulse Bypass System with XL4 Controller vers:all/* (CVE-2026-24790) CVSS Vendor Equipment Vulnerabilities v3 8.2 Welker Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-24790 The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication. View CVE Details Affected Products Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller Vendor: Welker Product Version: Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller: vers:all/* Product Status: known_affected Remediations Mitigation Welker did not respond to CISA's attempts at coordination. Users of Welker OdorEyes devices are encouraged to contact Welker and keep their systems up to date. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L Acknowledgments A project sponsored by DHS S&T reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-19 Date Revision Summary 2026-02-19 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EnOcean SmartServer IoT

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely execute arbitrary code and bypass ASLR. The following versions of EnOcean SmartServer IoT are affected: SmartServer IoT <=4.60.009 (CVE-2026-20761, CVE-2026-22885) CVSS Vendor Equipment Vulnerabilities v3 8.1 EnOcean Edge Inc EnOcean SmartServer IoT Improper Neutralization of Special Elements used in a Command…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely execute arbitrary code and bypass ASLR. The following versions of EnOcean SmartServer IoT are affected: SmartServer IoT <=4.60.009 (CVE-2026-20761, CVE-2026-22885) CVSS Vendor Equipment Vulnerabilities v3 8.1 EnOcean Edge Inc EnOcean SmartServer IoT Improper Neutralization of Special Elements used in a Command ('Command Injection'), Out-of-bounds Read Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-20761 A vulnerability exists in EnOcean SmartServer IoT version 4.60.009 and prior, which would allow remote attackers, in the LON IP-852 management messages, to send specially crafted IP-852 messages resulting in arbitrary OS command execution on the device. View CVE Details Affected Products EnOcean SmartServer IoT Vendor: EnOcean Edge Inc Product Version: EnOcean Edge Inc SmartServer IoT: <=4.60.009 Product Status: known_affected Remediations Mitigation EnOcean recommends users update the SmartServer platform software to SmartServer 4.6 Update 2 (v4.60.023) or a later release at: http://https//enoceanwiki.atlassian.net/wiki/spaces/IEC/pages/5275672/SmartServer+Release+Notes#Current-Stable-Release For additional mitigations and workarounds, refer to EnOcean's hardening guide at: https://enoceanwiki.atlassian.net/wiki/spaces/IEC/pages/288063529/Enhancing+Security. Relevant CWE: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-22885 A vulnerability exists in EnOcean SmartServer IoT version 4.60.009 and prior, which would allow remote attackers, in the LON IP-852 management messages, to send specially crafted IP-852 messages resulting in a memory leak from the program's memory. View CVE Details Affected Products EnOcean SmartServer IoT Vendor: EnOcean Edge Inc Product Version: EnOcean Edge Inc SmartServer IoT: <=4.60.009 Product Status: known_affected Remediations Mitigation EnOcean recommends users update the SmartServer platform software to SmartServer 4.6 Update 2 (v4.60.023) or a later release at: http://https//enoceanwiki.atlassian.net/wiki/spaces/IEC/pages/5275672/SmartServer+Release+Notes#Current-Stable-Release For additional mitigations and workarounds, refer to EnOcean's hardening guide at: https://enoceanwiki.atlassian.net/wiki/spaces/IEC/pages/288063529/Enhancing+Security. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments Amir Zaltzman of Claroty Team82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity. Revision History Initial Release Date: 2026-02-19 Date Revision Summary 2026-02-19 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Jinan USR IOT Technology Limited (PUSR) USR-W610

View CSAF Summary Successful exploitation of these vulnerabilities could result in authentication being disabled, a denial-of-service condition, or an attacker stealing valid user credentials, including administrator credentials. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 are affected: USR-W610 <=3.1.1.0 (CVE-2026-25715, CVE-2026-24455, CVE-2026-26049, CVE-2026-26048) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could result in authentication being disabled, a denial-of-service condition, or an attacker stealing valid user credentials, including administrator credentials. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 are affected: USR-W610 <=3.1.1.0 (CVE-2026-25715, CVE-2026-24455, CVE-2026-26049, CVE-2026-26048) CVSS Vendor Equipment Vulnerabilities v3 9.8 Jinan USR IOT Technology Limited (PUSR) Jinan USR IOT Technology Limited (PUSR) USR-W610 Weak Password Requirements, Cleartext Transmission of Sensitive Information, Insufficiently Protected Credentials, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-25715 The web management interface of the device allows the administrator username and password to be set to blank values. Once applied, the device permits authentication with empty credentials over the web management interface and Telnet service. This effectively disables authentication across all critical management channels, allowing any network-adjacent attacker to gain full administrative control without credentials. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610: <=3.1.1.0 Product Status: known_affected Remediations Vendor fix Jinan USR IOT Technology Limited (PUSR) has stated that the product is end-of-life, and there are no plans to patch. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-521 Weak Password Requirements Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-24455 The embedded web interface of the device does not support HTTPS/TLS for authentication and uses HTTP Basic Authentication. Traffic is encoded but not encrypted, exposing user credentials to passive interception by attackers on the same network. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610: <=3.1.1.0 Product Status: known_affected Remediations Vendor fix Jinan USR IOT Technology Limited (PUSR) has stated that the product is end-of-life, and there are no plans to patch. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-26049 The web management interface of the device renders the passwords in a plaintext input field. The current password is directly visible to anyone with access to the UI, potentially exposing administrator credentials to unauthorized observation via shoulder surfing, screenshots, or browser form caching. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610: <=3.1.1.0 Product Status: known_affected Remediations Vendor fix Jinan USR IOT Technology Limited (PUSR) has stated that the product is end-of-life, and there are no plans to patch. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.7 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N CVE-2026-26048 The Wi-Fi router is vulnerable to de-authentication attacks due to the absence of Management Frame Protection, allowing forged deauthentication and disassociation frames to be broadcast without authentication or encryption. An attacker can use this to cause unauthorized disruptions and create a denial-of-service condition. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610: <=3.1.1.0 Product Status: known_affected Remediations Vendor fix Jinan USR IOT Technology Limited (PUSR) has stated that the product is end-of-life, and there are no plans to patch. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Abhishek Pandey of Payatu Security Consulting reported CVE-2026-25715, CVE-2026-24455, and CVE-2026-26049 to CISA Abhishek Pandey and Ranit Pradhan of Payatu Security Consulting reported CVE-2026-26048 to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-19 Date Revision Summary 2026-02-19 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots