Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Mar 13, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Portwell Engineering Toolkits

View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to escalate privileges or cause a denial-of-service condition. The following versions of Portwell Engineering Toolkits are affected: Portwell Engineering Toolkits 4.8.2 CVSS Vendor Equipment Vulnerabilities v3 8.8 Portwell Portwell Engineering Toolkits Improper Restriction of Operations within the Bounds of a Memory Buffer…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to escalate privileges or cause a denial-of-service condition. The following versions of Portwell Engineering Toolkits are affected: Portwell Engineering Toolkits 4.8.2 CVSS Vendor Equipment Vulnerabilities v3 8.8 Portwell Portwell Engineering Toolkits Improper Restriction of Operations within the Bounds of a Memory Buffer Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-3437 An Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Portwell Engineering Toolkits version 4.8.2 could allow a local authenticated attacker to read and write to arbitrary memory via the Portwell Engineering Toolkits driver. Successful exploitation of this vulnerability could result in escalation of privileges or cause a denial-of-service condition. View CVE Details Affected Products Portwell Engineering Toolkits Vendor: Portwell Product Version: Portwell Portwell Engineering Toolkits: 4.8.2 Product Status: known_affected Remediations Vendor fix Portwell has not responded to requests to work with CISA to mitigate this vulnerability. Users of affected versions of Portwell Engineering Toolkits are invited to contact Portwell customer support (https://portwell.com/support.php) for additional information. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H Acknowledgments Jason Huang of Cyber Threat & Product Defense Center of TXOne Networks Inc. reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Labkotec LID-3300IP

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized control over system operations, leading to disruption of normal functionality and potential safety hazards. The following versions of Labkotec LID-3300IP are affected: LID-3300IP vers:all/* LID-3300IP Type 2 CVSS Vendor Equipment Vulnerabilities v3 9.4 Labkotec Labkotec LID-3300IP Missing Authentication for…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized control over system operations, leading to disruption of normal functionality and potential safety hazards. The following versions of Labkotec LID-3300IP are affected: LID-3300IP vers:all/* LID-3300IP Type 2 CVSS Vendor Equipment Vulnerabilities v3 9.4 Labkotec Labkotec LID-3300IP Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Communications, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-1775 The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device. View CVE Details Affected Products Labkotec LID-3300IP Vendor: Labkotec Product Version: Labkotec LID-3300IP: vers:all/*, Labkotec LID-3300IP Type 2: <V2.20 Product Status: known_affected Remediations Vendor fix Labkotec reports that it is not possible to implement secure and encrypted network traffic on the LID-3300IP. For this reason, Labkotec recommends updating ice detectors to the LID-3300IP Type 2 model and installing the latest firmware version V2.40. It is also highly recommended to activate HTTPS for network traffic. The device type and software version can be verified in the web interface. Mitigation Devices not connected to an Ethernet network are not susceptible to this attack. Ice detectors operating on secure internal networks that adhere to modern security standards, where only authorized devices and users have access, are protected against external threats. Mitigation Labkotec recommends implementing the following additional security controls: Do not connect the device to the public Internet Follow good security practices Change Default Credentials Enable Secure Management Access Network Segmentation Implement Firewall and Access Controls Restrict Protocols Monitor and Alert Avoid Direct Internet Exposure Keep Firmware Updated Control Physical Access Maintain Inventory and Access Reviews Mitigation Users can find more information in Labkotec's security advisory (https://labkotec.fi/wp-content/uploads/CA-000001-Cybersecurity-Advisory.pdf). Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ePower epower.ie

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of ePower epower.ie are affected: epower.ie vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 ePower ePower epower.ie Missing Authentication for Critical…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of ePower epower.ie are affected: epower.ie vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 ePower ePower epower.ie Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-22552 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-27778 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-24912 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27770 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mobility46 mobility46.se

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment Vulnerabilities v3 9.4 Mobility46 Mobility46 mobility46.se Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-27028 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-26305 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27647 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-22878 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EV Energy ev.energy

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EV Energy ev.energy are affected: ev.energy vers:all/* (CVE-2026-27772, CVE-2026-24445, CVE-2026-26290, CVE-2026-25774) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EV Energy ev.energy are affected: ev.energy vers:all/* (CVE-2026-27772, CVE-2026-24445, CVE-2026-26290, CVE-2026-25774) CVSS Vendor Equipment Vulnerabilities v3 9.4 EV Energy EV Energy ev.energy Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-27772 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-24445 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-26290 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-25774 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EV Energy ev.energy Vendor: EV Energy Product Version: EV Energy ev.energy: vers:all/* Product Status: known_affected Remediations Vendor fix EV Energy did not respond to CISA's request for coordination. Contact EV Energy using their contact page here: https://www.ev.energy/en-us for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Copeland XWEB and XWEB Pro

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication, cause a denial-of-service condition, cause memory corruption, and execute arbitrary code. The following versions of Copeland XWEB and XWEB Pro are affected: XWEB 300D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication, cause a denial-of-service condition, cause memory corruption, and execute arbitrary code. The following versions of Copeland XWEB and XWEB Pro are affected: XWEB 300D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) XWEB 500D PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) XWEB 500B PRO <=1.12.1 (CVE-2026-25085, CVE-2026-21718, CVE-2026-24663, CVE-2026-21389, CVE-2026-25111, CVE-2026-20742, CVE-2026-24517, CVE-2026-25195, CVE-2026-20910, CVE-2026-24689, CVE-2026-25109, CVE-2026-20902, CVE-2026-24695, CVE-2026-25105, CVE-2026-24452, CVE-2026-23702, CVE-2026-25721, CVE-2026-20764, CVE-2026-25196, CVE-2026-25037, CVE-2026-22877, CVE-2026-20797, CVE-2026-3037) CVSS Vendor Equipment Vulnerabilities v3 10 Copeland Copeland XWEB and XWEB Pro Unexpected Status Code or Return Value, Use of a Broken or Risky Cryptographic Algorithm, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-25085 A vulnerability exists in Copeland XWEB Pro version 1.12.1 and prior, in which an unexpected return value from the authentication routine is later on processed as a legitimate value, resulting in an authentication bypass. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-394 Unexpected Status Code or Return Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L CVE-2026-21718 An authentication bypass vulnerability exists in Copeland XWEB Pro version 1.12.1 and prior, enabling any attackers to bypass the authentication requirement and achieve pre-authenticated code execution on the system. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-24663 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an unauthenticated attacker to achieve remote code execution on the system by sending a crafted request to the libraries installation route and injecting malicious input into the request body. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-21389 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the request body sent to the contacts import route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25111 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the restore route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20742 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the templates route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24517 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into requests sent to the firmware update route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25195 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by supplying a crafted firmware update file via the firmware update route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20910 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field of the firmware update update action to achieve remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24689 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field of the firmware update apply action. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25109 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the devices field when accessing the get setup route, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20902 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the map filename field during the map upload action of the parameters route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24695 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into OpenSSL argument fields within requests sent to the utility route, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25105 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into parameters of the Modbus command tool in the debug route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-24452 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by supplying a crafted template file to the devices route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-23702 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by sending malicious input injected into the server username field of the import preconfiguration action in the API V1 route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25721 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the server username and/or password fields of the restore action in the API V1 route. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-20764 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by providing malicious input via the device hostname configuration which is later processed during system setup, resulting in remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25196 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by injecting malicious input into the Wi-Fi SSID and/or password fields can lead to remote code execution when the configuration is processed. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-25037 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by configuring a maliciously crafted LCD state which is later processed during system setup, enabling remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2026-22877 An arbitrary file-read vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling unauthenticated attackers to read arbitrary files on the system, and potentially causing a denial-of-service attack. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-20797 A stack based buffer overflow exists in an API route of XWEB Pro version 1.12.1 and prior, enabling unauthenticated attackers to cause stack corruption and a termination of the program. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L CVE-2026-3037 An OS Command injection vulnerability exists in XWEB Pro version 1.12.1 and prior, enabling an authenticated attacker to achieve remote code execution on the system by modifying malicious input injected into the MBird SMS service URL and/or code via the utility route which is later processed during system setup, leading to remote code execution. View CVE Details Affected Products Copeland XWEB and XWEB Pro Vendor: Copeland Product Version: Copeland XWEB 300D PRO: <=1.12.1, Copeland XWEB 500D PRO: <=1.12.1, Copeland XWEB 500B PRO: <=1.12.1 Product Status: known_affected Remediations Mitigation Copeland has provided a fix for the vulnerabilities and recommends users update the XWEB Pro to the latest version by going to their software update page https://webapps.copeland.com/Dixell/Pages/SystemSoftwareUpdate in the sections dedicated to the different XWEBPRO models page. Mitigation Alternatively, a user logged into an XWEB Pro with internet access can update XWEB Pro directly from Copeland servers via the menu SYSTEM -- Updates | Network. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Acknowledgments Amir Zaltzman and Noam Moshe of Claroty Team82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SWITCH EV swtchenergy.com

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773) CVSS Vendor Equipment Vulnerabilities v3 9.4 SWITCH EV SWITCH EV swtchenergy.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-27767 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25113 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25778 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27773 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Yokogawa CENTUM VP R6, R7

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to terminate the software stack process, cause a denial-of-service condition, or execute arbitrary code. The following versions of Yokogawa CENTUM VP R6, R7 are affected: Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to terminate the software stack process, cause a denial-of-service condition, or execute arbitrary code. The following versions of Yokogawa CENTUM VP R6, R7 are affected: Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022, CVE-2025-48023) Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300) <=R1.07.00 (CVE-2025-1924, CVE-2025-48019, CVE-2025-48020, CVE-2025-48021, CVE-2025-48022, CVE-2025-48023) CVSS Vendor Equipment Vulnerabilities v3 6.9 Yokogawa Yokogawa CENTUM VP R6, R7 Out-of-bounds Write, Reachable Assertion, Integer Underflow (Wrap or Wraparound), Improper Handling of Length Parameter Inconsistency Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-1924 If the affected product receives maliciously crafted packets, a DoS attack may cause Vnet/IP communication functions to stop or arbitrary programs to be executed. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.9 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:H CVE-2025-48019 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48020 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48021 If theaffected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-191 Integer Underflow (Wrap or Wraparound) Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48022 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-48023 If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. View CVE Details Affected Products Yokogawa CENTUM VP R6, R7 Vendor: Yokogawa Product Version: Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300): <=R1.07.00, Yokogawa Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300): <=R1.07.00 Product Status: known_affected Remediations Mitigation Yokogawa recommends users apply patch software (R1.08.00). Mitigation Yokogawa recommends users contact a local supporting office for further information or support. https://contact.yokogawa.com/cs/gw?c-id=000498 Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0002 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0002-E.pdf Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Dmitry Sklyar and Demid Uzenkov of Positive Technologies reported these vulnerabilities to Yokogawa Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. These vulnerabilities have a high attack complexity. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Republication of YSAR-26-0002 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls, Inc. Frick Controls Quantum HD

View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities v3 9.1 Johnson Controls, Inc. Johnson Controls, Inc. Frick Controls Quantum HD Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Control of Generation of Code ('Code Injection'), Relative Path Traversal, Plaintext Storage of a Password Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21654 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21656 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21657 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21658 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21659 The Frick Controls Quantum HD contains a vulnerability that allows an unauthenticated attacker to execute arbitrary code on the affected device, leading to full system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-21660 Hardcoded credentials in the Frick Controls Quantum HD create a vulnerability that leads to unauthorized access, exposure of sensitive information, and potential misuse or system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-256 Plaintext Storage of a Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.2 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Noam Moshe of Claroty Research Team 82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Chargemap chargemap.com

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment Vulnerabilities v3 9.4 Chargemap Chargemap chargemap.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-25851 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-20792 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or misrouting legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25711 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-20791 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots