· CISA Cybersecurity Advisory

Siemens SICAM SIAPP SDK

View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens…
Read full source summary
View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens has released a new version for SICAM SIAPP SDK and recommends to update to the latest version. The following versions of Siemens SICAM SIAPP SDK are affected: SICAM SIAPP SDK vers:intdot/<2.1.7 CVSS Vendor Equipment Vulnerabilities v3 7.4 Siemens Siemens SICAM SIAPP SDK Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25569 An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25570 The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25571 The SICAM SIAPP SDK client component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25572 The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25573 The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25605 The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. Maxime Rossi Bellom of Secmate reported these vulnerabilities to Siemens. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-903736 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-17 2 Initial CISA Republication of Siemens ProductCERT SSA-903736 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Data Center Expert

View CSAF Summary Schneider Electric is aware of a hard-coded credentials vulnerability in its EcoStruxure IT Data Center Expert (DCE) product that requires administrator credentials and enabling a feature (SOCKS Proxy) that is off by default. The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive…
Read full source summary
View CSAF Summary Schneider Electric is aware of a hard-coded credentials vulnerability in its EcoStruxure IT Data Center Expert (DCE) product that requires administrator credentials and enabling a feature (SOCKS Proxy) that is off by default. The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure, and remote compromise of the offer which could result in disruption of operations and access to system data. The following versions of Schneider Electric EcoStruxure Data Center Expert are affected: EcoStruxure IT Data Center Expert vers:intdot/<=9.0 EcoStruxure IT Data Center Expert 9.1 CVSS Vendor Equipment Vulnerabilities v3 7.2 Schneider Electric Schneider Electric EcoStruxure Data Center Expert Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13957 A hard-coded credentials vulnerability exists that could lead to information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. View CVE Details Affected Products Schneider Electric EcoStruxure Data Center Expert Vendor: Schneider Electric Product Version: EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) v9.0 and prior Product Status: fixed, known_affected Remediations Vendor fix v9.1 of EcoStruxure IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data-center-expert/#software-and-firmware Mitigation If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Harden the DCE instance according to the cybersecurity best practices documented in the EcoStruxure IT Data Center Expert Security Handbook • Ensure the SOCKS Proxy is disabled as in the default configuration. Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert PDF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-05.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert CSAF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-05.json Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments hassan ali of TrendAI Zero Day Initiative reported this vulnerability to Schneider Electric General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices: * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-05 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric SEVD-2026-069-05 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric SCADAPack and RemoteConnect

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. The following versions of Schneider Electric SCADAPack and RemoteConnect are affected: SCADAPack™ vers:generic/ SCADAPack™ firmware vers:intdot/<9.12.2, 9.12.2, vers:intdot/<9.12.2, 9.12.2 () RemoteConnect vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric SCADAPack and RemoteConnect Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-0667 CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol. View CVE Details Affected Products Schneider Electric SCADAPack and RemoteConnect Vendor: Schneider Electric Product Version: SCADAPack™ 57x All Versions, RemoteConnect Versions prior to R3.4.2 Product Status: fixed, known_affected Remediations Vendor fix Version R3.4.2 (Firmware version 9.12.2) of SCADAPack™ 47x and SCADAPack™ 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Vendor fix Version R3.4.2 of RemoteConnect includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service. Mitigation Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services. • Disable the logic debug service. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-041-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-10 Date Revision Summary 2026-02-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-041-01 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CODESYS in Festo Automation Suite

View CSAF Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* FESTO…
Read full source summary
View CSAF Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 FESTO, CODESYS CODESYS in Festo Automation Suite Direct Request ('Forced Browsing'), Untrusted Search Path, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Recursion, Improper Access Control, Use of Insufficiently Random Values, Improper Restriction of Communication Channel to Intended Endpoints, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), NULL Pointer Dereference, Stack-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Incorrect Permission Assignment for Critical Resource, Improper Handling of Exceptional Conditions, Exposure of Resource to Wrong Sphere, Allocation of Resources Without Limits or Throttling, Use of a Broken or Risky Cryptographic Algorithm, Out-of-bounds Write, Weak Password Recovery Mechanism for Forgotten Password, Improper Privilege Management, Use of Password Hash With Insufficient Computational Effort, Buffer Access with Incorrect Length Value, Improper Input Validation, Improper Verification of Cryptographic Signature, Inadequate Encryption Strength, Origin Validation Error, Missing Release of Memory after Effective Lifetime, Improper Resource Shutdown or Release, Deserialization of Untrusted Data, Path Equivalence: '//multiple/leading/slash', Insufficient Verification of Data Authenticity, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Out-of-bounds Read, Failure to Sanitize Special Elements into a Different Plane (Special Element Injection), Use of Out-of-range Pointer Offset, Improper Neutralization of Script in Attributes of IMG Tags in a Web Page, Files or Directories Accessible to External Parties, Untrusted Pointer Dereference, Path Traversal: '....' (Multiple Dot), ASP.NET Misconfiguration: Missing Custom Error Page, Uncontrolled Resource Consumption, Unprotected Transport of Credentials, Initialization of a Resource with an Insecure Default, Heap-based Buffer Overflow, Unexpected Sign Extension, Buffer Over-read, Uncontrolled Search Path Element, Improper Verification of Source of a Communication Channel, Improper Restriction of Excessive Authentication Attempts, Use After Free, ASP.NET Misconfiguration: Password in Configuration File, Improper Check for Unusual or Exceptional Conditions, Observable Discrepancy, Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-2595 An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-425 Direct Request ('Forced Browsing') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2010-5250 Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory.NOTE: some of these details are obtained from third party information. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-426 Untrusted Search Path Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.8 HIGH CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2017-3735 While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2018-0739 Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-674 Uncontrolled Recursion Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H CVE-2018-10612 In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2018-20025 Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-330 Use of Insufficiently Random Values Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2018-20026 Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-923 Improper Restriction of Communication Channel to Intended Endpoints Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2019-13532 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2019-13538 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H CVE-2019-13542 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2019-13548 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-18858 CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-19789 3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2019-5105 An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9008 An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2019-9009 An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9010 An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-9011 In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2019-9012 An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9013 An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-10245 CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-12067 In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user's password may be changed by an attacker without knowledge of the current password. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-640 Weak Password Recovery Mechanism for Forgotten Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-12068 An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-269 Improper Privilege Management Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2020-12069 In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational Effort Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2020-14509 Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-805 Buffer Access with Incorrect Length Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-14513 CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2020-14515 CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-14517 Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-326 Inadequate Encryption Strength Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-14519 This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-346 Origin Validation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-15806 CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2020-16233 An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2020-7052 CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2021-21863 A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21864 A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21865 A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21866 A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21867 An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21868 An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21869 An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-29239 CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-345 Insufficient Verification of Data Authenticity Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2021-29240 The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-345 Insufficient Verification of Data Authenticity Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-29241 CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-29242 CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2021-30186 CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-30187 CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L CVE-2021-30188 CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-30190 CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-30195 CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-33485 CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-33486 All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-34593 In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-75 Failure to Sanitize Special Elements into a Different Plane (Special Element Injection) Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-34595 A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2021-34596 A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2021-36763 In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2021-36764 In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-36765 In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2022-1965 Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2022-1989 All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2022-22508 Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L CVE-2022-22513 An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 6.5 MEDIUM CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-22514 An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-822 Untrusted Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H CVE-2022-22515 A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N CVE-2022-22516 The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-22517 An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-33 Path Traversal: '....' (Multiple Dot) Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-22519 A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-12 ASP.NET Misconfiguration: Missing Custom Error Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-30791 In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-30792 In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-31805 In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-523 Unprotected Transport of Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2022-31806 In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2022-32136 In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32137 In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-32138 In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-194 Unexpected Sign Extension Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-32139 In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32140 Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32141 Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32142 Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.1 HIGH CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2022-32143 In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-4046 In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.8 HIGH CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-4048 Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-326 Inadequate Encryption Strength Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2022-4224 In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47378 Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47379 An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47380 An authenticated remote attacker may use a stack basedout-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47381 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47383 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47384 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47385 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47386 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47387 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47388 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47389 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47390 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47391 In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-47392 An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47393 An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-3662 In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context . View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2023-3663 In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2023-3669 A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.3 LOW CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N CVE-2023-3670 In CODESYS Development System 3.5.9.0 to 3.5.17.0 and CODESYS Scripting 4.0.0.0 to 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2023-37545 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37546 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37547 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37548 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37549 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37550 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37551 In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N CVE-2023-37552 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37553 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37554 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37555 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37556 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37557 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37558 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37559 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-3935 A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2023-49675 An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2023-49676 An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H CVE-2023-6357 A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2024-5000 An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-13 ASP.NET Misconfiguration: Password in Configuration File Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-8175 An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-0694 Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-1468 An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-203 Observable Discrepancy Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2025-41658 CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-276 Incorrect Default Permissions Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N CVE-2025-41659 A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2020-11023 In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing option elements from untrusted sources - even after sanitizing it - to one of jQuery's DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N CVE-2022-47382 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments CERT@VDE reported this vulnerability to Festo Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-17 Date Revision Summary 2026-03-17 1 Initial Republication of Festo SE & Co. KG FSA-202601 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-47813 Wing FTP Server Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-47813 Wing FTP Server Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3909 Google Skia Out-of-Bounds Write Vulnerability CVE-2026-3910 Google Chromium V8 Unspecified Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3909 Google Skia Out-of-Bounds Write Vulnerability CVE-2026-3910 Google Chromium V8 Unspecified Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Siemens SIDIS Prime

View CSAF Summary SIDIS Prime before V4.0.800 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, and several Node.js packages as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version. The following versions of Siemens SIDIS Prime are affected: SIDIS Prime vers:intdot/<4.0.800 (CVE-2024-29857, CVE-2024-30171, CVE-2024-30172,…
Read full source summary
View CSAF Summary SIDIS Prime before V4.0.800 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, and several Node.js packages as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version. The following versions of Siemens SIDIS Prime are affected: SIDIS Prime vers:intdot/<4.0.800 (CVE-2024-29857, CVE-2024-30171, CVE-2024-30172, CVE-2024-41996, CVE-2025-6965, CVE-2025-7783, CVE-2025-9230, CVE-2025-9232, CVE-2025-9670, CVE-2025-12816, CVE-2025-15284, CVE-2025-58751, CVE-2025-58752, CVE-2025-58754, CVE-2025-62522, CVE-2025-64718, CVE-2025-64756, CVE-2025-66030, CVE-2025-66031, CVE-2025-66035, CVE-2025-66412, CVE-2025-69277, CVE-2026-22610) CVSS Vendor Equipment Vulnerabilities v3 8.7 Siemens Siemens SIDIS Prime Out-of-bounds Read, Observable Discrepancy, Improper Input Validation, Improper Certificate Validation, Numeric Truncation Error, Use of Insufficiently Random Values, Out-of-bounds Write, Inefficient Regular Expression Complexity, Interpretation Conflict, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Relative Path Traversal, Allocation of Resources Without Limits or Throttling, Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Integer Overflow or Wraparound, Uncontrolled Recursion, Insertion of Sensitive Information Into Sent Data, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Incomplete List of Disallowed Inputs Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2024-29857 An issue was discovered in ECCurve.java and ECCurve.cs in Bouncy Castle Java (BC Java) before 1.78, BC Java LTS before 2.73.6, BC-FJA before 1.0.2.5, and BC C# .Net before 2.3.1. Importing an EC certificate with crafted F2m parameters can lead to excessive CPU consumption during the evaluation of the curve parameters. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-30171 An issue was discovered in Bouncy Castle Java TLS API and JSSE Provider before 1.78. Timing-based leakage may occur in RSA based handshakes because of exception processing. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-203 Observable Discrepancy Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2024-30172 An issue was discovered in Bouncy Castle Java Cryptography APIs before 1.78. An Ed25519 verification code infinite loop can occur via a crafted signature and public key. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-41996 Validating the order of the public keys in the Diffie-Hellman Key Agreement Protocol, when an approved safe prime is used, allows remote attackers (from the client side) to trigger unnecessarily expensive server-side DHE modular-exponentiation calculations. The client may cause asymmetric resource consumption. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE and validate the order of the public key. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-295 Improper Certificate Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-6965 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-197 Numeric Truncation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L CVE-2025-7783 Use of Insufficiently Random Values vulnerability in form-data allows HTTP Parameter Pollution (HPP). This vulnerability is associated with program files lib/form_data.Js. This issue affects form-data: < 2.5.4, 3.0.0 - 3.0.3, 4.0.0 - 4.0.3. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-330 Use of Insufficiently Random Values Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N CVE-2025-9230 An application trying to decrypt CMS messages encrypted using password based encryption can trigger an out-of-bounds read and write. Impact summary: This out-of-bounds read may trigger a crash which leads to Denial of Service for an application. The out-of-bounds write can cause a memory corruption which can have various consequences including a Denial of Service or Execution of attacker-supplied code. Although the consequences of a successful exploit of this vulnerability could be severe, the probability that the attacker would be able to perform it is low. Besides, password based (PWRI) encryption support in CMS messages is very rarely used. For that reason the issue was assessed as Moderate severity according to our Security Policy. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.6 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2025-9232 Issue summary: An application using the OpenSSL HTTP client API functions may trigger an out-of-bounds read if the 'no_proxy' environment variable is set and the host portion of the authority component of the HTTP URL is an IPv6 address. Impact summary: An out-of-bounds read can trigger a crash which leads to Denial of Service for an application. The OpenSSL HTTP client API functions can be used directly by applications but they are also used by the OCSP client functions and CMP (Certificate Management Protocol) client implementation in OpenSSL. However the URLs used by these implementations are unlikely to be controlled by an attacker. In this vulnerable code the out of bounds read can only trigger a crash. Furthermore the vulnerability requires an attacker-controlled URL to be passed from an application to the OpenSSL function and the user has to have a 'no_proxy' environment variable set. For the aforementioned reasons the issue was assessed as Low severity. The vulnerable code was introduced in the following patch releases: 3.0.16, 3.1.8, 3.2.4, 3.3.3, 3.4.0 and 3.5.0. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as the HTTP client implementation is outside the OpenSSL FIPS module boundary. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-9670 A security flaw has been discovered in mixmark-io turndown up to 7.2.1. This affects an unknown function of the file src/commonmark-rules.js. Performing manipulation results in inefficient regular expression complexity. It is possible to initiate the attack remotely. The exploit has been released to the public and may be exploited. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-1333 Inefficient Regular Expression Complexity Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L CVE-2025-12816 An interpretation-conflict (CWE-436) vulnerability in node-forge versions 1.3.1 and earlier enables unauthenticated attackers to craft ASN.1 structures to desynchronize schema validations, yielding a semantic divergence that may bypass downstream cryptographic verifications and security decisions. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-436 Interpretation Conflict Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N CVE-2025-15284 Improper Input Validation vulnerability in qs (parse modules) allows HTTP DoS.This issue affects qs: < 6.14.1. SummaryThe arrayLimit option in qs does not enforce limits for bracket notation (a[]=1&a[]=2), allowing attackers to cause denial-of-service via memory exhaustion. Applications using arrayLimit for DoS protection are vulnerable. DetailsThe arrayLimit option only checks limits for indexed notation (a[0]=1&a[1]=2) but completely bypasses it for bracket notation (a[]=1&a[]=2). Vulnerable code (lib/parse.js:159-162): if (root === '[]' && options.parseArrays) { obj = utils.combine([], leaf); // No arrayLimit check } Working code (lib/parse.js:175): else if (index <= options.arrayLimit) { // Limit checked here obj = []; obj[index] = leaf; } The bracket notation handler at line 159 uses utils.combine([], leaf) without validating against options.arrayLimit, while indexed notation at line 175 checks index <= options.arrayLimit before creating arrays. PoCTest 1 - Basic bypass: npm install qs const qs = require('qs'); const result = qs.parse('a[]=1&a[]=2&a[]=3&a[]=4&a[]=5&a[]=6', { arrayLimit: 5 }); console.log(result.a.length); // Output: 6 (should be max 5) Test 2 - DoS demonstration: const qs = require('qs'); const attack = 'a[]=' + Array(10000).fill('x').join('&a[]='); const result = qs.parse(attack, { arrayLimit: 100 }); console.log(result.a.length); // Output: 10000 (should be max 100) Configuration: * arrayLimit: 5 (test 1) or arrayLimit: 100 (test 2) * Use bracket notation: a[]=value (not indexed a[0]=value) ImpactDenial of Service via memory exhaustion. Affects applications using qs.parse() with user-controlled input and arrayLimit for protection. Attack scenario: * Attacker sends HTTP request: GET /api/search?filters[]=x&filters[]=x&...&filters[]=x (100,000+ times) * Application parses with qs.parse(query, { arrayLimit: 100 }) * qs ignores limit, parses all 100,000 elements into array * Server memory exhausted → application crashes or becomes unresponsive * Service unavailable for all users Real-world impact: * Single malicious request can crash server * No authentication required * Easy to automate and scale * Affects any endpoint parsing query strings with bracket notation View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-58751 Vite is a frontend tooling framework for JavaScript. Prior to versions 7.1.5, 7.0.7, 6.3.6, and 5.4.20, files starting with the same name with the public directory were served bypassing the `server.fs` settings. Only apps that explicitly expose the Vite dev server to the network (using --host or `server.host` config option), use the public directory feature (enabled by default), and have a symlink in the public directory are affected. Versions 7.1.5, 7.0.7, 6.3.6, and 5.4.20 fix the issue. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N CVE-2025-58752 Vite is a frontend tooling framework for JavaScript. Prior to versions 7.1.5, 7.0.7, 6.3.6, and 5.4.20, any HTML files on the machine were served regardless of the `server.fs` settings. Only apps that explicitly expose the Vite dev server to the network (using --host or server.host config option) and use `appType: 'spa'` (default) or `appType: 'mpa'` are affected. This vulnerability also affects the preview server. The preview server allowed HTML files not under the output directory to be served. Versions 7.1.5, 7.0.7, 6.3.6, and 5.4.20 fix the issue. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N CVE-2025-58754 Axios is a promise based HTTP client for the browser and Node.js. When Axios starting in version 0.28.0 and prior to versions 0.30.2 and 1.12.0 runs on Node.js and is given a URL with the `data:` scheme, it does not perform HTTP. Instead, its Node http adapter decodes the entire payload into memory (`Buffer`/`Blob`) and returns a synthetic 200 response. This path ignores `maxContentLength` / `maxBodyLength` (which only protect HTTP responses), so an attacker can supply a very large `data:` URI and cause the process to allocate unbounded memory and crash (DoS), even if the caller requested `responseType: 'stream'`. Versions 0.30.2 and 1.12.0 contain a patch for the issue. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-62522 Vite is a frontend tooling framework for JavaScript. In versions from 2.9.18 to before 3.0.0, 3.2.9 to before 4.0.0, 4.5.3 to before 5.0.0, 5.2.6 to before 5.4.21, 6.0.0 to before 6.4.1, 7.0.0 to before 7.0.8, and 7.1.0 to before 7.1.11, files denied by server.fs.deny were sent if the URL ended with \ when the dev server is running on Windows. Only apps explicitly exposing the Vite dev server to the network and running the dev server on Windows were affected. This issue has been patched in versions 5.4.21, 6.4.1, 7.0.8, and 7.1.11. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N CVE-2025-64718 js-yaml is a JavaScript YAML parser and dumper. In js-yaml before 4.1.1 and 3.14.2, it's possible for an attacker to modify the prototype of the result of a parsed yaml document via prototype pollution (`__proto__`). All users who parse untrusted yaml documents may be impacted. The problem is patched in js-yaml 4.1.1 and 3.14.2. Users can protect against this kind of attack on the server by using `node --disable-proto=delete` or `deno` (in Deno, pollution protection is on by default). View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-1321 Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2025-64756 Glob matches files using patterns the shell uses. Starting in version 10.2.0 and prior to versions 10.5.0 and 11.1.0, the glob CLI contains a command injection vulnerability in its -c/--cmd option that allows arbitrary command execution when processing files with malicious names. When glob -c are used, matched filenames are passed to a shell with shell: true, enabling shell metacharacters in filenames to trigger command injection and achieve arbitrary code execution under the user or CI account privileges. This issue has been patched in versions 10.5.0 and 11.1.0. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-66030 Forge (also called `node-forge`) is a native implementation of Transport Layer Security in JavaScript. An Integer Overflow vulnerability in node-forge versions 1.3.1 and below enables remote, unauthenticated attackers to craft ASN.1 structures containing OIDs with oversized arcs. These arcs may be decoded as smaller, trusted OIDs due to 32-bit bitwise truncation, enabling the bypass of downstream OID-based security decisions. This issue has been patched in version 1.3.2. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2025-66031 Forge (also called `node-forge`) is a native implementation of Transport Layer Security in JavaScript. An Uncontrolled Recursion vulnerability in node-forge versions 1.3.1 and below enables remote, unauthenticated attackers to craft deep ASN.1 structures that trigger unbounded recursive parsing. This leads to a Denial-of-Service (DoS) via stack exhaustion when parsing untrusted DER inputs. This issue has been patched in version 1.3.2. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-674 Uncontrolled Recursion Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-66035 Angular is a development platform for building mobile and desktop web applications using TypeScript/JavaScript and other languages. Prior to versions 19.2.16, 20.3.14, and 21.0.1, there is a XSRF token leakage via protocol-relative URLs in angular HTTP clients. The vulnerability is a Credential Leak by App Logic that leads to the unauthorized disclosure of the Cross-Site Request Forgery (XSRF) token to an attacker-controlled domain. Angular's HttpClient has a built-in XSRF protection mechanism that works by checking if a request URL starts with a protocol (http:// or https://) to determine if it is cross-origin. If the URL starts with protocol-relative URL (//), it is incorrectly treated as a same-origin request, and the XSRF token is automatically added to the X-XSRF-TOKEN header. This issue has been patched in versions 19.2.16, 20.3.14, and 21.0.1. A workaround for this issue involves avoiding using protocol-relative URLs (URLs starting with //) in HttpClient requests. All backend communication URLs should be hardcoded as relative paths (starting with a single /) or fully qualified, trusted absolute URLs. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-201 Insertion of Sensitive Information Into Sent Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N CVE-2025-66412 Angular is a development platform for building mobile and desktop web applications using TypeScript/JavaScript and other languages. Prior to 21.0.2, 20.3.15, and 19.2.17, A Stored Cross-Site Scripting (XSS) vulnerability has been identified in the Angular Template Compiler. It occurs because the compiler's internal security schema is incomplete, allowing attackers to bypass Angular's built-in security sanitization. Specifically, the schema fails to classify certain URL-holding attributes (e.g., those that could contain javascript: URLs) as requiring strict URL security, enabling the injection of malicious scripts. This vulnerability is fixed in 21.0.2, 20.3.15, and 19.2.17. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2025-69277 libsodium before ad3004e, in atypical use cases involving certain custom cryptography or untrusted data to crypto_core_ed25519_is_valid_point, mishandles checks for whether an elliptic curve point is valid because it sometimes allows points that aren't in the main cryptographic group. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-184 Incomplete List of Disallowed Inputs Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.5 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N CVE-2026-22610 Angular is a development platform for building mobile and desktop web applications using TypeScript/JavaScript and other languages. Prior to versions 19.2.18, 20.3.16, 21.0.7, and 21.1.0-rc.0, a cross-site scripting (XSS) vulnerability has been identified in the Angular Template Compiler. The vulnerability exists because Angular’s internal sanitization schema fails to recognize the href and xlink:href attributes of SVG elements as a Resource URL context. This issue has been patched in versions 19.2.18, 20.3.16, 21.0.7, and 21.1.0-rc.0. View CVE Details Affected Products Siemens SIDIS Prime Vendor: Siemens Product Version: SIDIS Prime Product Status: known_affected Remediations Vendor fix Update to V4.0.800 or later version Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-485750 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-485750 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/*, vers:all/* (CVE-2026-24858, CVE-2025-55018, CVE-2025-62439,…
Read full source summary
View CSAF Summary Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/*, vers:all/* (CVE-2026-24858, CVE-2025-55018, CVE-2025-62439, CVE-2025-64157) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens RUGGEDCOM APE1808 Devices Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Improper Verification of Source of a Communication Channel, Use of Externally-Controlled Format String, Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-55018 An inconsistent interpretation of http requests ('http request smuggling') vulnerability in Fortinet FortiOS 7.6.0, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4.3 through 6.4.16 may allow an unauthenticated attacker to smuggle an unlogged http request through the firewall policies via a specially crafted header View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-444 Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N CVE-2025-62439 An inconsistent interpretation of http requests ('http request smuggling') vulnerability in Fortinet FortiOS 7.6.0, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4.3 through 6.4.16 may allow an unauthenticated attacker to smuggle an unlogged http request through the firewall policies via a specially crafted header. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version with FSSO TS Agent version 5.0 build 0324 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.2 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N CVE-2025-64157 A use of externally-controlled format string vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0 all versions allows an authenticated admin to execute unauthorized code or commands via specifically crafted configuration. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-134 Use of Externally-Controlled Format String Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-24858 An authentication bypass using an alternate path or channel vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.5, FortiAnalyzer 7.4.0 through 7.4.9, FortiAnalyzer 7.2.0 through 7.2.11, FortiAnalyzer 7.0.0 through 7.0.15, FortiManager 7.6.0 through 7.6.5, FortiManager 7.4.0 through 7.4.9, FortiManager 7.2.0 through 7.2.11, FortiManager 7.0.0 through 7.0.15, FortiOS 7.6.0 through 7.6.5, FortiOS 7.4.0 through 7.4.10, FortiOS 7.2.0 through 7.2.12, FortiOS 7.0.0 through 7.0.18 may allow an attacker with a FortiCloud account and a registered device to log into other devices registered to other accounts, if FortiCloud SSO authentication is enabled on those devices. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.11 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-975644 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-975644 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products…
Read full source summary
View CSAF Summary SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V2 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Industrial OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516T-3 PN (6ES7516-3TP10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516TF-3 PN (6ES7516-3UP10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517-3 PN (6ES7517-3AQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN (6ES7517-3FQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517H-4 PN (6ES7517-4HQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517T-3 PN (6ES7517-3TQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517TF-3 PN (6ES7517-3UQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-3 PN (6ES7518-3AT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-3 PN (6ES7518-3FT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518T-3 PN (6ES7518-3TT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518TF-3 PN (6ES7518-3UT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S T V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S TF V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller Linux V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller Linux V3 vers:all/* (CVE-2025-40943) SIMATIC S7-PLCSIM Advanced vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) vers:all/* (CVE-2025-40943) CVSS Vendor Equipment Vulnerabilities v3 9.6 Siemens Siemens SIMATIC Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40943 Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering a legitimate user to import a specially crafted trace file View CVE Details Affected Products Siemens SIMATIC Vendor: Siemens Product Version: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0), SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0), SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0), SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0), SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0), SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DK03-0AB0), SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0), SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0), SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0), SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DM03-0AB0), SIMATIC ET 200SP CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0), SIMATIC ET 200SP CPU 1514SP-2 PN (6ES7514-2DN03-0AB0), SIMATIC ET 200SP CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0), SIMATIC ET 200SP CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V2 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Industrial OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Windows OS, SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0), SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0), SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0), SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0), SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN (6ES7516-3TP10-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN (6ES7516-3UP10-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0), SIMATIC S7-1500 CPU 1517-3 PN (6ES7517-3AQ10-0AB0), SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN (6ES7517-3FQ10-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0), SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0), SIMATIC S7-1500 CPU 1517H-4 PN (6ES7517-4HQ10-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN (6ES7517-3TQ10-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN (6ES7517-3UQ10-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0), SIMATIC S7-1500 CPU 1518-3 PN (6ES7518-3AT10-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0), SIMATIC S7-1500 CPU 1518F-3 PN (6ES7518-3FT10-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JT10-0AB0), SIMATIC S7-1500 CPU 1518T-3 PN (6ES7518-3TT10-0AB0), SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0), SIMATIC S7-1500 CPU 1518TF-3 PN (6ES7518-3UT10-0AB0), SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0), SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0), SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0), SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0), SIMATIC S7-1500 Software Controller CPU 1507S F V2, SIMATIC S7-1500 Software Controller CPU 1507S F V3, SIMATIC S7-1500 Software Controller CPU 1507S F V4, SIMATIC S7-1500 Software Controller CPU 1507S V2, SIMATIC S7-1500 Software Controller CPU 1507S V3, SIMATIC S7-1500 Software Controller CPU 1507S V4, SIMATIC S7-1500 Software Controller CPU 1508S F V2, SIMATIC S7-1500 Software Controller CPU 1508S F V3, SIMATIC S7-1500 Software Controller CPU 1508S F V4, SIMATIC S7-1500 Software Controller CPU 1508S T V3, SIMATIC S7-1500 Software Controller CPU 1508S TF V3, SIMATIC S7-1500 Software Controller CPU 1508S V2, SIMATIC S7-1500 Software Controller CPU 1508S V3, SIMATIC S7-1500 Software Controller CPU 1508S V4, SIMATIC S7-1500 Software Controller Linux V2, SIMATIC S7-1500 Software Controller Linux V3, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0), SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0), SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0), SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0), SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0), SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0), SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0), SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0), SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0), SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0), SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0), SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0), SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0), SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0), SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0), SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0), SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0), SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0), SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0), SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0), SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0), SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0), SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0), SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) Product Status: known_affected Remediations Mitigation Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only Mitigation Only upload trusted trace files None available Currently no fix is available Vendor fix Update to V4.1.2 or later version Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.6 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-452276 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-452276 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Trane Tracer SC, Tracer SC+, and Tracer Concierge

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, execute arbitrary commands, or perform a denial-of-service on the product. The following versions of Trane Tracer SC, Tracer SC+, and Tracer Concierge are affected: Tracer SC Tracer SC+ Tracer Concierge CVSS Vendor Equipment Vulnerabilities v3 8.1 Trane Trane Tracer SC, Tracer SC+, and Tracer…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, execute arbitrary commands, or perform a denial-of-service on the product. The following versions of Trane Tracer SC, Tracer SC+, and Tracer Concierge are affected: Tracer SC Tracer SC+ Tracer Concierge CVSS Vendor Equipment Vulnerabilities v3 8.1 Trane Trane Tracer SC, Tracer SC+, and Tracer Concierge Use of a Broken or Risky Cryptographic Algorithm, Memory Allocation with Excessive Size Value, Missing Authorization, Use of Hard-coded Credentials, Use of Hard-coded, Security-relevant Constants Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-28252 A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to bypass authentication and gain root-level access to the device. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310, Trane Tracer Concierge: <v6.3.2310 Product Status: known_affected Remediations Vendor fix Trane has released the following versions of Tracer SC+ for users to upgrade to: Vendor fix CVE-2026-28252, CVE-2026-28253, CVE-2026-28254: Tracer SC+ version v6.30.2313 Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.1 HIGH CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-28253 A Memory Allocation with Excessive Size Value vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an unauthenticated attacker to cause a denial-of-service condition. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310, Trane Tracer Concierge: <v6.3.2310 Product Status: known_affected Remediations Vendor fix Trane has released the following versions of Tracer SC+ for users to upgrade to: Vendor fix CVE-2026-28252, CVE-2026-28253, CVE-2026-28254: Tracer SC+ version v6.30.2313 Relevant CWE: CWE-789 Memory Allocation with Excessive Size Value Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-28254 A Missing Authorization vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an unauthenticated attacker to access sensitive information through unprotected APIs. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310, Trane Tracer Concierge: <v6.3.2310 Product Status: known_affected Remediations Vendor fix Trane has released the following versions of Tracer SC+ for users to upgrade to: Vendor fix CVE-2026-28252, CVE-2026-28253, CVE-2026-28254: Tracer SC+ version v6.30.2313 Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.0 5.8 MEDIUM CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N CVE-2026-28255 A Use of Hard-coded Credentials vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310, Trane Tracer Concierge: <v6.3.2310 Product Status: known_affected Remediations Vendor fix Trane has released the following versions of Tracer SC+ for users to upgrade to: Mitigation CVE-2026-28255: Trane has implemented enhanced cloud security controls to mitigate this vulnerability. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N CVE-2026-28256 A Use of Hard-coded, Security-relevant Constants vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310, Trane Tracer Concierge: <v6.3.2310 Product Status: known_affected Remediations Vendor fix Trane has released the following versions of Tracer SC+ for users to upgrade to: Mitigation CVE-2026-28256: Trane has implemented enhanced security controls which have been communicated to their customers. For more information, contact Trane. Relevant CWE: CWE-547 Use of Hard-coded, Security-relevant Constants Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N Acknowledgments Noam Moshe of Claroty reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-12 Date Revision Summary 2026-03-12 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Heliox EV Chargers

View CSAF Summary Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Heliox EV Chargers are affected: Heliox Flex 180 kW EV Charging Station Heliox Mobile DC 40 kW…
Read full source summary
View CSAF Summary Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Heliox EV Chargers are affected: Heliox Flex 180 kW EV Charging Station Heliox Mobile DC 40 kW EV Charging Station CVSS Vendor Equipment Vulnerabilities v3 2.6 Siemens Siemens Heliox EV Chargers Improper Restriction of Communication Channel to Intended Endpoints Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-27769 Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable. View CVE Details Affected Products Siemens Heliox EV Chargers Vendor: Siemens Product Version: Heliox Flex 180 kW EV Charging Station, Heliox Mobile DC 40 kW EV Charging Station Product Status: known_affected Remediations Vendor fix Contact customer support for patch information via OTA update Relevant CWE: CWE-923 Improper Restriction of Communication Channel to Intended Endpoints Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.6 LOW CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-126399 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-126399 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Inductive Automation Ignition Software

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. The following versions of Inductive Automation Ignition Software are affected: Ignition Software <8.3.0 (CVE-2025-13913) CVSS Vendor Equipment Vulnerabilities v3 6.3 Inductive…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. The following versions of Inductive Automation Ignition Software are affected: Ignition Software <8.3.0 (CVE-2025-13913) CVSS Vendor Equipment Vulnerabilities v3 6.3 Inductive Automation Inductive Automation Ignition Software Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13913 A privileged Ignition user, intentionally or otherwise, imports an external file with a specially crafted payload, which executes embedded malicious code during deserialization. View CVE Details Affected Products Inductive Automation Ignition Software Vendor: Inductive Automation Product Version: Inductive Automation Ignition Software: <8.3.0 Product Status: known_affected Remediations Mitigation Fix - upgrade Ignition software from 8.1.x to 8.3.0 or greater. Mitigation MITIGATION (8.1.x Linux). Implement Ignition Security Hardening Guide Appendix A. https://inductiveautomation.com/resources/article/ignition-security-hardening-guide Mitigation MITIGATION (8.1.x Windows). Covered in Ignition Security Hardening Guide Appendix A. 1. Create a new dedicated local Windows account that will be used exclusively for the Ignition service (e.g. svc-ign). a. The best security practice is that the Ignition service should not be a domain account (unless otherwise needed). b. Remove all group memberships from the service account (including Users and Administrators). c. Add to security policy to log in as a service. d. Add to "Deny log on locally" security policy. 2. Provide full read/write access only to the Ignition installation directory for the service account created in #1. a. Add read/write permissions to other directories in the local filesystem as needed (e.g.: if configured to use optional Enterprise Administration Module to write automated backups to the file system). 3. Set deny access settings for service account on other directories not needed by the Ignition service. a. Specifically the C:\Windows, C:\Users, and directories for any other applications in the Program Files or Program Files(x86) directories. b. Use java param to change temp directory to a location within the Ignition install directory so the Users folder can be denied access to the Ignition service account. Mitigation BEST PRACTICES (8.1.x and 8.3.x)4. Restrict project imports to verified and trusted sources only, ideally using checksums or digital signatures.5. Use multiple environments (e.g. Dev, Test, Prod) with a staging workflow so that new data is never introduced directly to Production environments. See Ignition Deployment Best Practices.6. When feasible, segment or isolate Ignition gateways from corporate resources and Windows Domains.a. The Ignition service account or AD server object should never need Windows Domain or Windows Active Directory privileges. This would only be needed if an Asset Owners IT or OT department uses this for management outside Ignition.b. Ignition may be federated with Active Directory environments (e.g. OT domains) by entering "Authentication Profile" credentials within the Ignition gateway itself. This could use secure LDAP, SAML, or OpenID Connect.7. When feasible, enforce strong credential management and MFA for all users with Designer permissions (8.1.x and 8.3.x), Config Page permissions (8.1.x), and Config Write permissions (8.3.x).8. When feasible, deploy Ignition within hardened or containerized environments. Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H Acknowledgments Nik Tsytsarkin, Ismail Aydemir, and Ryan Hall of Meta reported this vulnerability to Inductive Automation Nathan Boeger and Joel Specht of Inductive Automation (security@inductiveautomation.com) reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-03-12 Date Revision Summary 2026-03-12 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-68613 n8n Improper Control of Dynamically-Managed Code Resources Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-68613 n8n Improper Control of Dynamically-Managed Code Resources Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Honeywell IQ4x BMS Controller

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4x BMS Controller are affected: IQ4E >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ412 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4x BMS Controller are affected: IQ4E >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ412 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ422 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ4NC >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ41x >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ3 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQECO >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) CVSS Vendor Equipment Vulnerabilities v3 10 Honeywell Honeywell IQ4x BMS Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Government Services and Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3611 The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration. View CVE Details Affected Products Honeywell IQ4x BMS Controller Vendor: Honeywell Product Version: Honeywell IQ4E: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ412: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ422: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ4NC: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ41x: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ3: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQECO: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 Product Status: known_affected Remediations Mitigation Honeywell is aware of the issue, but has not released a fix. For more information, contact Honeywell directly. https://www.honeywell.com/us/en/contact. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Gjoko Krstic of Zero Science reported this vulnerability to Honeywell Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Ceragon Siklu MultiHaul and EtherHaul Series

View CSAF Summary Successful exploitation of this vulnerability could result in arbitrary file upload to the target equipment. The following versions of Ceragon Siklu MultiHaul and EtherHaul Series are affected: MultiHaul MH-B100-CCS MultiHaul MH-T200-CCC MultiHaul MH-T200-CNN MultiHaul MH-T201-CNN EtherHaul EH-8010FX EtherHaul EH-500TX EtherHaul EH-600TX EtherHaul EH-614TX EtherHaul EH-700TX EtherHaul EH-710TX…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in arbitrary file upload to the target equipment. The following versions of Ceragon Siklu MultiHaul and EtherHaul Series are affected: MultiHaul MH-B100-CCS MultiHaul MH-T200-CCC MultiHaul MH-T200-CNN MultiHaul MH-T201-CNN EtherHaul EH-8010FX EtherHaul EH-500TX EtherHaul EH-600TX EtherHaul EH-614TX EtherHaul EH-700TX EtherHaul EH-710TX EtherHaul EH-1200TX EtherHaul EH-1200FX EtherHaul EH-2200FX EtherHaul EH-2500FX EtherHaul EH-5500FD CVSS Vendor Equipment Vulnerabilities v3 5.3 Ceragon Ceragon Siklu MultiHaul and EtherHaul Series Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: Israel Vulnerabilities Expand All + CVE-2025-57176 The rfpiped service on TCP port 555 in Ceragon Networks / Siklu Communication EtherHaul and MultiHaul Series microwave antennas allow unauthenticated file uploads to any writable location on the device. File upload packets use weak encryption (metadata only) with file contents transmitted in cleartext. No authentication or path validation is performed. View CVE Details Affected Products Ceragon Siklu MultiHaul and EtherHaul Series Vendor: Ceragon Product Version: Ceragon MultiHaul MH-B100-CCS: <R2.4.0, Ceragon MultiHaul MH-T200-CCC: <R2.4.0, Ceragon MultiHaul MH-T200-CNN: <R2.4.0, Ceragon MultiHaul MH-T201-CNN: <R2.4.0, Ceragon EtherHaul EH-8010FX: <R10.8.1, Ceragon EtherHaul EH-500TX: <R7.7.12, Ceragon EtherHaul EH-600TX: <R7.7.12, Ceragon EtherHaul EH-614TX: <R7.7.12, Ceragon EtherHaul EH-700TX: <R7.7.12, Ceragon EtherHaul EH-710TX: <R7.7.12, Ceragon EtherHaul EH-1200TX: <R7.7.12, Ceragon EtherHaul EH-1200FX: <R7.7.12, Ceragon EtherHaul EH-2200FX: <R7.7.12, Ceragon EtherHaul EH-2500FX: <R7.7.12, Ceragon EtherHaul EH-5500FD: <R7.7.12 Product Status: known_affected Remediations Vendor fix Ceragon has released a software update for the affected models: Vendor fix Affected users should install firmware version R2.4.0 for affected MultiHaul models. Vendor fix Affected users should install firmware version R10.8.1 for the affected EH-8010FX model. Vendor fix Affected users should install firmware version R7.7.12 for other affected EtherHaul models. Mitigation Additionally Ceragon has provided the following security recommendations for mitigating the listed vulnerability. To prevent exposure, management access must follow standard operator security guidelines: Mitigation Management IP addresses must use private subnets (RFC 1918) Mitigation Management networks must be protected by: *-* Firewalls *-* Access Control Lists *-* Network Access Translation / Secure management domains Mitigation Firewalls Mitigation Access Control Lists Mitigation Network Access Translation / Secure management domains Mitigation Public exposure of management IP Addresses is not supported nor recommendedCeragon requests that affected users please verify that all affected radio units: Mitigation Use private management IP addresses only Mitigation Are placed behind internal security controls Mitigation Follow your organization's authentication and access-control policies Mitigation Please visit the Ceragon portal here: https://portal.ceragon.com/ (login required) for further information. Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments CISA discovered a public Proof of Concept (PoC) as authored by semaja22 and reported it to Ceragon Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this (these) vulnerability(ies), such as: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Apeman Cameras

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During Web Page…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-11126 A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-11851 A vulnerability has been found in Apeman ID71 EN75.8.53.20. The affected element is an unknown function of the file /set_alias.cgi. Such manipulation of the argument alias leads to cross site scripting. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N CVE-2025-11852 A vulnerability was found in Apeman ID71 218.53.203.117. The impacted element is an unknown function of the file /onvif/device_service of the component ONVIF Service. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments CISA discovered the PoCs (Proof of Concept) as authored by Julio Urena Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Lantronix EDS3000PS and EDS5000

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor Equipment Vulnerabilities v3 9.8 Lantronix Lantronix EDS3000PS and EDS5000 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Authentication Bypass Using an Alternate Path or Channel, Unverified Password Change Background Critical Infrastructure Sectors: Communications, Information Technology, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-67034 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67035 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The SSH Client and SSH Server pages are affected by multiple OS injection vulnerabilities due to missing sanitization of input parameters. An attacker can inject arbitrary commands in delete actions of various objects, such as server keys, users, and known hosts. Commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67036 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenticated attacker can inject arbitrary OS commands that are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67037 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67038 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-67039 An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The authentication on management pages can be bypassed by appending a specific suffix to the URL and by sending an Authorization header that uses "admin" as the username. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-70082 The administrator password can be changed without knowledge of the current password. When chained with an authentication bypass vulnerability, this issue may allow unauthenticated attackers to modify the administrator password. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.7 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N CVE-2025-67041 An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The host parameter of the TFTP client in the Filesystem Browser page is not properly sanitized. This can be exploited to escape from the original command and execute an arbitrary one with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Francesco La Spina and Stanislav Dashevskyi of Forescout Technologies reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Delta Electronics CNCSoft-G2

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker achieving remote code execution on the device. The following versions of Delta Electronics CNCSoft-G2 are affected: CNCSoft-G2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics CNCSoft-G2 Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker achieving remote code execution on the device. The following versions of Delta Electronics CNCSoft-G2 are affected: CNCSoft-G2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics CNCSoft-G2 Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-3094 Delta Electronics CNCSoft-G2 devices prior to version V2.1.0.39 are vulnerable to an Out-of-Bounds Write while parsing DPAX files in the DOPSoft component. View CVE Details Affected Products Delta Electronics CNCSoft-G2 Vendor: Delta Electronics Product Version: Delta Electronics CNCSoft-G2: <V2.1.0.39 Product Status: known_affected Remediations Mitigation Delta Electronics recommends users update to Version 2.1.0.39, which has resolved this vulnerability. The update can be obtained from the Delta Electronics download center at https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=cncsoft&sort_expr=cdate&sort_dir=DESC. Mitigation For more information, see the associated Delta Electronics security advisory Delta-PCSA-2026-00004 which can be downloaded in PDF format here: https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00004_CNCSoft-G2_File%20Parsing%20Out-Of-Bounds%20Write.pdf Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Natnael Samson (@NattiSamson) of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. CISA recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-03-05 Date Revision Summary 2026-03-05 1 Initial Republication of Delta Electronics Delta-PCSA-2026-00004 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Five Known Exploited Vulnerabilities to Catalog

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2017-7921 Hikvision Multiple Products Improper Authentication Vulnerability CVE-2021-22681 Rockwell Multiple Products Insufficient Protected Credentials Vulnerability CVE-2021-30952 Apple Multiple Products Integer Overflow or Wraparound Vulnerability CVE-2023-41974 Apple iOS and…
Read full source summary
CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2017-7921 Hikvision Multiple Products Improper Authentication Vulnerability CVE-2021-22681 Rockwell Multiple Products Insufficient Protected Credentials Vulnerability CVE-2021-30952 Apple Multiple Products Integer Overflow or Wraparound Vulnerability CVE-2023-41974 Apple iOS and iPadOS Use-After-Free Vulnerability CVE-2023-43000 Apple Multiple products Use-After-Free Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.