Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Mar 19, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds Five Known Exploited Vulnerabilities to Catalog

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2017-7921 Hikvision Multiple Products Improper Authentication Vulnerability CVE-2021-22681 Rockwell Multiple Products Insufficient Protected Credentials Vulnerability CVE-2021-30952 Apple Multiple Products Integer Overflow or Wraparound Vulnerability CVE-2023-41974 Apple iOS and…
Read full source summary
CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2017-7921 Hikvision Multiple Products Improper Authentication Vulnerability CVE-2021-22681 Rockwell Multiple Products Insufficient Protected Credentials Vulnerability CVE-2021-30952 Apple Multiple Products Integer Overflow or Wraparound Vulnerability CVE-2023-41974 Apple iOS and iPadOS Use-After-Free Vulnerability CVE-2023-43000 Apple Multiple products Use-After-Free Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Delta Electronics CNCSoft-G2

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker achieving remote code execution on the device. The following versions of Delta Electronics CNCSoft-G2 are affected: CNCSoft-G2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics CNCSoft-G2 Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker achieving remote code execution on the device. The following versions of Delta Electronics CNCSoft-G2 are affected: CNCSoft-G2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics CNCSoft-G2 Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-3094 Delta Electronics CNCSoft-G2 devices prior to version V2.1.0.39 are vulnerable to an Out-of-Bounds Write while parsing DPAX files in the DOPSoft component. View CVE Details Affected Products Delta Electronics CNCSoft-G2 Vendor: Delta Electronics Product Version: Delta Electronics CNCSoft-G2: <V2.1.0.39 Product Status: known_affected Remediations Mitigation Delta Electronics recommends users update to Version 2.1.0.39, which has resolved this vulnerability. The update can be obtained from the Delta Electronics download center at https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=cncsoft&sort_expr=cdate&sort_dir=DESC. Mitigation For more information, see the associated Delta Electronics security advisory Delta-PCSA-2026-00004 which can be downloaded in PDF format here: https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00004_CNCSoft-G2_File%20Parsing%20Out-Of-Bounds%20Write.pdf Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Natnael Samson (@NattiSamson) of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. CISA recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-03-05 Date Revision Summary 2026-03-05 1 Initial Republication of Delta Electronics Delta-PCSA-2026-00004 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Labkotec LID-3300IP

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized control over system operations, leading to disruption of normal functionality and potential safety hazards. The following versions of Labkotec LID-3300IP are affected: LID-3300IP vers:all/* LID-3300IP Type 2 CVSS Vendor Equipment Vulnerabilities v3 9.4 Labkotec Labkotec LID-3300IP Missing Authentication for…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow attackers to gain unauthorized control over system operations, leading to disruption of normal functionality and potential safety hazards. The following versions of Labkotec LID-3300IP are affected: LID-3300IP vers:all/* LID-3300IP Type 2 CVSS Vendor Equipment Vulnerabilities v3 9.4 Labkotec Labkotec LID-3300IP Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Communications, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-1775 The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device. View CVE Details Affected Products Labkotec LID-3300IP Vendor: Labkotec Product Version: Labkotec LID-3300IP: vers:all/*, Labkotec LID-3300IP Type 2: <V2.20 Product Status: known_affected Remediations Vendor fix Labkotec reports that it is not possible to implement secure and encrypted network traffic on the LID-3300IP. For this reason, Labkotec recommends updating ice detectors to the LID-3300IP Type 2 model and installing the latest firmware version V2.40. It is also highly recommended to activate HTTPS for network traffic. The device type and software version can be verified in the web interface. Mitigation Devices not connected to an Ethernet network are not susceptible to this attack. Ice detectors operating on secure internal networks that adhere to modern security standards, where only authorized devices and users have access, are protected against external threats. Mitigation Labkotec recommends implementing the following additional security controls: Do not connect the device to the public Internet Follow good security practices Change Default Credentials Enable Secure Management Access Network Segmentation Implement Firewall and Access Controls Restrict Protocols Monitor and Alert Avoid Direct Internet Exposure Keep Firmware Updated Control Physical Access Maintain Inventory and Access Reviews Mitigation Users can find more information in Labkotec's security advisory (https://labkotec.fi/wp-content/uploads/CA-000001-Cybersecurity-Advisory.pdf). Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ePower epower.ie

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of ePower epower.ie are affected: epower.ie vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 ePower ePower epower.ie Missing Authentication for Critical…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of ePower epower.ie are affected: epower.ie vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 ePower ePower epower.ie Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-22552 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-27778 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-24912 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27770 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products ePower epower.ie Vendor: ePower Product Version: ePower epower.ie: vers:all/* Product Status: known_affected Remediations Vendor fix ePower did not respond to CISA's request for coordination. Contact ePower using their contact page here: https://www.epower.ie/support/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module

View CSAF Summary Successful exploitation of these vulnerabilities could allow a remote attacker to cause a denial-of-service condition by continuously sending UDP packets to the affected products. The following versions of Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module are affected: MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP <=1.106, vers:all/* (CVE-2026-1874,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow a remote attacker to cause a denial-of-service condition by continuously sending UDP packets to the affected products. The following versions of Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module are affected: MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP <=1.106, vers:all/* (CVE-2026-1874, CVE-2026-1876) MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP vers:all/* (CVE-2026-1874, CVE-2026-1875) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module Always-Incorrect Control Flow Implementation, Improper Resource Shutdown or Release Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-1874 An always-incorrect control flow implementation vulnerability may allow a remote attacker to cause a denial-of-service condition by continuously sending UDP packets to the affected products. View CVE Details Affected Products Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: <=1.106, Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP: vers:all/* Product Status: known_affected Remediations Vendor fix Users of FX5-ENET/IP versions 1.106 and prior should download the update file for version 1.107 or later and apply it. The update file is available at: https://www.mitsubishielectric.com/fa/download/index.html. Mitigation The fixed version for the FX5-EIP is scheduled to be released in the near future. In the meantime, users should apply mitigations or workarounds. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. and preventing unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the IP filter function of the affected product and blocking access from untrusted hosts, to minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to “13.1 IP Filter Function” in the MELSEC iQ-F FX5 User’s Manual (Communication). Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For more information, see Mitsubishi Electric 2025-021. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-021_en.pdf Relevant CWE: CWE-670 Always-Incorrect Control Flow Implementation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-1875 An improper resource shutdown or release vulnerability in the affected products may allow a remote attacker to cause a denial-of-service condition by continuously sending UDP packets. View CVE Details Affected Products Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP: vers:all/* Product Status: known_affected Remediations Mitigation The fixed version for the FX5-EIP is scheduled to be released in the near future. In the meantime, users should apply mitigations or workarounds. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. and preventing unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the IP filter function of the affected product and blocking access from untrusted hosts, to minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to “13.1 IP Filter Function” in the MELSEC iQ-F FX5 User’s Manual (Communication). Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For more information, see Mitsubishi Electric 2025-021. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-021_en.pdf Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-1876 An improper resource shutdown or release vulnerability may allow a remote attacker to cause a denial-of-service condition in the affected products by continuously sending UDP packets. View CVE Details Affected Products Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: vers:all/* Product Status: known_affected Remediations No fix planned Users should apply mitigations or workarounds since there are no plans to release a fixed version. Mitigation For users of products that do not have a fixed version, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. and preventing unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version, Mitsubishi Electric recommends using the IP filter function of the affected product and blocking access from untrusted hosts, to minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to “13.1 IP Filter Function” in the MELSEC iQ-F FX5 User’s Manual (Communication). Mitigation For users of products that do not have a fixed version, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For users of products that do not have a fixed version, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For more information, see Mitsubishi Electric 2025-021. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-021_en.pdf Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Mitsubishi Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this notification (https://www.cisa.gov/notification) and this privacy & use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a republication of Mitsubishi Electric security advisory "2025-021 Multiple denial-of-service vulnerabilities in Ethernet function of MELSEC iQ-F Series EtherNet/IP module and Ethernet module" from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication 2026-03-03 2 Initial CISA Republication of Mitsubishi Electric security advisory 2025-021 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy Relion REB500 Product

View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the Relion REB500 product versions listed in this document. Authenticated users with certain roles can exploit the vulnerabilities to access and modify the directory contents they are not authorized to do so. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi…
Read full source summary
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the Relion REB500 product versions listed in this document. Authenticated users with certain roles can exploit the vulnerabilities to access and modify the directory contents they are not authorized to do so. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Relion REB500 Product are affected: Relion REB500 vers:Relion_REB500/<=8.3.3.0 (CVE-2026-2459, CVE-2026-2460) CVSS Vendor Equipment Vulnerabilities v3 6.8 Hitachi Energy Hitachi Energy Relion REB500 Product Privilege Defined With Unsafe Actions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-2459 A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so. View CVE Details Affected Products Hitachi Energy Relion REB500 Product Vendor: Hitachi Energy Product Version: REB500 versions 8.3.3.0 and prior Product Status: known_affected Remediations Vendor fix Hitachi Energy recommends that users update to version 8.3.3.1. Mitigation For CVE-2026-2459, as a mitigation strategy, users may also disable the Installer role and enable it only during the firmware update process. Relevant CWE: CWE-267 Privilege Defined With Unsafe Actions Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N CVE-2026-2460 A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so. View CVE Details Affected Products Hitachi Energy Relion REB500 Product Vendor: Hitachi Energy Product Version: REB500 versions 8.3.3.0 and prior Product Status: known_affected Remediations Vendor fix Update to version 8.3.3.1 Mitigation Apply general mitigation factors Relevant CWE: CWE-267 Privilege Defined With Unsafe Actions Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N Acknowledgments Hitachi Energy reported this vulnerability to CISA. Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000217 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-24 Date Revision Summary 2026-02-24 1 Initial public release 2026-03-03 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000217 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy RTU500 Product

View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. Successful exploitation of these vulnerabilities can result in the exposure of low-value user management information and device outage. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are…
Read full source summary
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. Successful exploitation of these vulnerabilities can result in the exposure of low-value user management information and device outage. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are affected: RTU500 series CMU Firmware vers:RTU500_series_CMU_Firmware/>=12.7.1|<=12.7.7, vers:RTU500_series_CMU_Firmware/>=13.5.1|<=13.5.4, vers:RTU500_series_CMU_Firmware/>=13.6.1|<=13.6.2, vers:RTU500_series_CMU_Firmware/>=13.7.1|<=13.7.7, 13.8.1 CVSS Vendor Equipment Vulnerabilities v3 7.5 Hitachi Energy Hitachi Energy RTU500 Product Improper Handling of Insufficient Permissions or Privileges , Incomplete List of Disallowed Inputs, Uncontrolled Recursion, Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-1772 RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges. View CVE Details Affected Products Hitachi Energy RTU500 Product Vendor: Hitachi Energy Product Version: RTU500 series CMU Firmware version 12.7.1 through 12.7.7, RTU500 series CMU Firmware version 13.5.1 through 13.5.4, RTU500 series CMU Firmware version 13.6.1 through 13.6.2, RTU500 series CMU Firmware version 13.7.1 through 13.7.7, RTU500 series CMU Firmware version 13.8.1 Product Status: known_affected Remediations Vendor fix Update to CMU Firmware version 12.7.8 Mitigation Follow general mitigation factors/workarounds Vendor fix Update to CMU Firmware version 13.7.8 or latest Vendor fix Update to CMU Firmware version 13.8.2 Relevant CWE: CWE-280 Improper Handling of Insufficient Permissions or Privileges Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N CVE-2026-1773 IEC 60870-5-104: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation. View CVE Details Affected Products Hitachi Energy RTU500 Product Vendor: Hitachi Energy Product Version: RTU500 series CMU Firmware version 12.7.1 through 12.7.7, RTU500 series CMU Firmware version 13.5.1 through 13.5.4, RTU500 series CMU Firmware version 13.6.1 through 13.6.2, RTU500 series CMU Firmware version 13.7.1 through 13.7.7, RTU500 series CMU Firmware version 13.8.1 Product Status: known_affected Remediations Vendor fix Update to CMU Firmware version 12.7.8 Mitigation Follow general mitigation factors/workarounds Vendor fix Update to CMU Firmware version 13.7.8 or latest Vendor fix Update to CMU Firmware version 13.8.2 Relevant CWE: CWE-184 Incomplete List of Disallowed Inputs Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-8176 A stack overflow vulnerability exists in the libexpat library due to the way it handles recursive entity expansion in XML documents. When parsing an XML document with deeply nested entity references, libexpat can be forced to recurse indefinitely, exhausting the stack space and causing a crash. This issue could lead to denial of service (DoS) or, in some cases, exploitable memory corruption, depending on the environment and library usage. Product is only affected if IEC61850 functionality is configured. View CVE Details Affected Products Hitachi Energy RTU500 Product Vendor: Hitachi Energy Product Version: RTU500 series CMU Firmware version 12.7.1 through 12.7.7, RTU500 series CMU Firmware version 13.5.1 through 13.5.4, RTU500 series CMU Firmware version 13.6.1 through 13.6.2, RTU500 series CMU Firmware version 13.7.1 through 13.7.7, RTU500 series CMU Firmware version 13.8.1 Product Status: known_affected Remediations Vendor fix Update to CMU Firmware version 12.7.8 Mitigation Follow general mitigation factors/workarounds Vendor fix Update to CMU Firmware version 13.7.8 or latest Vendor fix Update to CMU Firmware version 13.8.2 Relevant CWE: CWE-674 Uncontrolled Recursion Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-59375 libexpat in Expat before 2.7.2 allows attackers to trigger large dynamic memory allocations via a small document that is submitted for parsing. Product is only affected if IEC61850 functionality is configured. View CVE Details Affected Products Hitachi Energy RTU500 Product Vendor: Hitachi Energy Product Version: RTU500 series CMU Firmware version 12.7.1 through 12.7.7, RTU500 series CMU Firmware version 13.5.1 through 13.5.4, RTU500 series CMU Firmware version 13.6.1 through 13.6.2, RTU500 series CMU Firmware version 13.7.1 through 13.7.7, RTU500 series CMU Firmware version 13.8.1 Product Status: known_affected Remediations Vendor fix Update to CMU Firmware version 12.7.8 Mitigation Follow general mitigation factors/workarounds Vendor fix Update to CMU Firmware version 13.7.8 or latest Vendor fix Update to CMU Firmware version 13.8.2 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Hitachi Energy PSIRT reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000237 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-24 Date Revision Summary 2026-02-24 1 Initial public release 2026-03-03 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000237 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Everon OCPP Backends

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Everon OCPP Backends are affected: api.everon.io vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 Everon Everon OCPP Backends Missing Authentication for…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Everon OCPP Backends are affected: api.everon.io vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 Everon Everon OCPP Backends Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Netherlands Vulnerabilities Expand All + CVE-2026-26288 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Everon OCPP Backends Vendor: Everon Product Version: Everon api.everon.io: vers:all/* Product Status: known_affected Remediations Mitigation Everon has shut down their platform on December 1st, 2025. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-24696 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Everon OCPP Backends Vendor: Everon Product Version: Everon api.everon.io: vers:all/* Product Status: known_affected Remediations Mitigation Everon has shut down their platform on December 1st, 2025. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-20748 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Everon OCPP Backends Vendor: Everon Product Version: Everon api.everon.io: vers:all/* Product Status: known_affected Remediations Mitigation Everon has shut down their platform on December 1st, 2025. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27027 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Everon OCPP Backends Vendor: Everon Product Version: Everon api.everon.io: vers:all/* Product Status: known_affected Remediations Mitigation Everon has shut down their platform on December 1st, 2025. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mobiliti e-mobi.hu

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobiliti e-mobi.hu are affected: e-mobi.hu vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 Mobiliti Mobiliti e-mobi.hu Missing Authentication for…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobiliti e-mobi.hu are affected: e-mobi.hu vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 Mobiliti Mobiliti e-mobi.hu Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Hungary Vulnerabilities Expand All + CVE-2026-26051 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Mobiliti e-mobi.hu Vendor: Mobiliti Product Version: Mobiliti e-mobi.hu: vers:all/* Product Status: known_affected Remediations Mitigation Mobiliti did not respond to CISA's request for coordination. Contact Mobiliti using their contact page here: https://www.mobiliti.hu/emobilitas/ugyfeltamogatas/ugyfelszolgalat for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-20882 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Mobiliti e-mobi.hu Vendor: Mobiliti Product Version: Mobiliti e-mobi.hu: vers:all/* Product Status: known_affected Remediations Mitigation Mobiliti did not respond to CISA's request for coordination. Contact Mobiliti using their contact page here: https://www.mobiliti.hu/emobilitas/ugyfeltamogatas/ugyfelszolgalat for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27764 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Mobiliti e-mobi.hu Vendor: Mobiliti Product Version: Mobiliti e-mobi.hu: vers:all/* Product Status: known_affected Remediations Mitigation Mobiliti did not respond to CISA's request for coordination. Contact Mobiliti using their contact page here: https://www.mobiliti.hu/emobilitas/ugyfeltamogatas/ugyfelszolgalat for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27777 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Mobiliti e-mobi.hu Vendor: Mobiliti Product Version: Mobiliti e-mobi.hu: vers:all/* Product Status: known_affected Remediations Mitigation Mobiliti did not respond to CISA's request for coordination. Contact Mobiliti using their contact page here: https://www.mobiliti.hu/emobilitas/ugyfeltamogatas/ugyfelszolgalat for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-03 Date Revision Summary 2026-03-03 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots