Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Mar 20, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/*, vers:all/* (CVE-2026-24858, CVE-2025-55018, CVE-2025-62439,…
Read full source summary
View CSAF Summary Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/*, vers:all/* (CVE-2026-24858, CVE-2025-55018, CVE-2025-62439, CVE-2025-64157) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens RUGGEDCOM APE1808 Devices Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Improper Verification of Source of a Communication Channel, Use of Externally-Controlled Format String, Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-55018 An inconsistent interpretation of http requests ('http request smuggling') vulnerability in Fortinet FortiOS 7.6.0, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4.3 through 6.4.16 may allow an unauthenticated attacker to smuggle an unlogged http request through the firewall policies via a specially crafted header View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-444 Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N CVE-2025-62439 An inconsistent interpretation of http requests ('http request smuggling') vulnerability in Fortinet FortiOS 7.6.0, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4.3 through 6.4.16 may allow an unauthenticated attacker to smuggle an unlogged http request through the firewall policies via a specially crafted header. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version with FSSO TS Agent version 5.0 build 0324 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.2 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N CVE-2025-64157 A use of externally-controlled format string vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0 all versions allows an authenticated admin to execute unauthorized code or commands via specifically crafted configuration. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.10 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-134 Use of Externally-Controlled Format String Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-24858 An authentication bypass using an alternate path or channel vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.5, FortiAnalyzer 7.4.0 through 7.4.9, FortiAnalyzer 7.2.0 through 7.2.11, FortiAnalyzer 7.0.0 through 7.0.15, FortiManager 7.6.0 through 7.6.5, FortiManager 7.4.0 through 7.4.9, FortiManager 7.2.0 through 7.2.11, FortiManager 7.0.0 through 7.0.15, FortiOS 7.6.0 through 7.6.5, FortiOS 7.4.0 through 7.4.10, FortiOS 7.2.0 through 7.2.12, FortiOS 7.0.0 through 7.0.18 may allow an attacker with a FortiCloud account and a registered device to log into other devices registered to other accounts, if FortiCloud SSO authentication is enabled on those devices. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.4.11 or later version. Contact customer support to receive patch and update information. Mitigation For more information see the associated Siemens security advisory SSA-975644 in HTML https://cert-portal.siemens.com/productcert/html/ssa-975644.html Mitigation For more information see the associated Siemens security advisory SSA-975644 in CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-975644.json Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-975644 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-975644 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Inductive Automation Ignition Software

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. The following versions of Inductive Automation Ignition Software are affected: Ignition Software <8.3.0 (CVE-2025-13913) CVSS Vendor Equipment Vulnerabilities v3 6.3 Inductive…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. The following versions of Inductive Automation Ignition Software are affected: Ignition Software <8.3.0 (CVE-2025-13913) CVSS Vendor Equipment Vulnerabilities v3 6.3 Inductive Automation Inductive Automation Ignition Software Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13913 A privileged Ignition user, intentionally or otherwise, imports an external file with a specially crafted payload, which executes embedded malicious code during deserialization. View CVE Details Affected Products Inductive Automation Ignition Software Vendor: Inductive Automation Product Version: Inductive Automation Ignition Software: <8.3.0 Product Status: known_affected Remediations Mitigation Fix - upgrade Ignition software from 8.1.x to 8.3.0 or greater. Mitigation MITIGATION (8.1.x Linux). Implement Ignition Security Hardening Guide Appendix A. https://inductiveautomation.com/resources/article/ignition-security-hardening-guide Mitigation MITIGATION (8.1.x Windows). Covered in Ignition Security Hardening Guide Appendix A. 1. Create a new dedicated local Windows account that will be used exclusively for the Ignition service (e.g. svc-ign). a. The best security practice is that the Ignition service should not be a domain account (unless otherwise needed). b. Remove all group memberships from the service account (including Users and Administrators). c. Add to security policy to log in as a service. d. Add to "Deny log on locally" security policy. 2. Provide full read/write access only to the Ignition installation directory for the service account created in #1. a. Add read/write permissions to other directories in the local filesystem as needed (e.g.: if configured to use optional Enterprise Administration Module to write automated backups to the file system). 3. Set deny access settings for service account on other directories not needed by the Ignition service. a. Specifically the C:\Windows, C:\Users, and directories for any other applications in the Program Files or Program Files(x86) directories. b. Use java param to change temp directory to a location within the Ignition install directory so the Users folder can be denied access to the Ignition service account. Mitigation BEST PRACTICES (8.1.x and 8.3.x)4. Restrict project imports to verified and trusted sources only, ideally using checksums or digital signatures.5. Use multiple environments (e.g. Dev, Test, Prod) with a staging workflow so that new data is never introduced directly to Production environments. See Ignition Deployment Best Practices.6. When feasible, segment or isolate Ignition gateways from corporate resources and Windows Domains.a. The Ignition service account or AD server object should never need Windows Domain or Windows Active Directory privileges. This would only be needed if an Asset Owners IT or OT department uses this for management outside Ignition.b. Ignition may be federated with Active Directory environments (e.g. OT domains) by entering "Authentication Profile" credentials within the Ignition gateway itself. This could use secure LDAP, SAML, or OpenID Connect.7. When feasible, enforce strong credential management and MFA for all users with Designer permissions (8.1.x and 8.3.x), Config Page permissions (8.1.x), and Config Write permissions (8.3.x).8. When feasible, deploy Ignition within hardened or containerized environments. Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H Acknowledgments Nik Tsytsarkin, Ismail Aydemir, and Ryan Hall of Meta reported this vulnerability to Inductive Automation Nathan Boeger and Joel Specht of Inductive Automation (security@inductiveautomation.com) reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-03-12 Date Revision Summary 2026-03-12 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Heliox EV Chargers

View CSAF Summary Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Heliox EV Chargers are affected: Heliox Flex 180 kW EV Charging Station Heliox Mobile DC 40 kW…
Read full source summary
View CSAF Summary Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Heliox EV Chargers are affected: Heliox Flex 180 kW EV Charging Station Heliox Mobile DC 40 kW EV Charging Station CVSS Vendor Equipment Vulnerabilities v3 2.6 Siemens Siemens Heliox EV Chargers Improper Restriction of Communication Channel to Intended Endpoints Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-27769 Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable. View CVE Details Affected Products Siemens Heliox EV Chargers Vendor: Siemens Product Version: Heliox Flex 180 kW EV Charging Station, Heliox Mobile DC 40 kW EV Charging Station Product Status: known_affected Remediations Vendor fix Contact customer support for patch information via OTA update Relevant CWE: CWE-923 Improper Restriction of Communication Channel to Intended Endpoints Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.6 LOW CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-126399 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-126399 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products…
Read full source summary
View CSAF Summary SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V2 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Industrial OS vers:all/* (CVE-2025-40943) SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Windows OS vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516T-3 PN (6ES7516-3TP10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1516TF-3 PN (6ES7516-3UP10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517-3 PN (6ES7517-3AQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN (6ES7517-3FQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517H-4 PN (6ES7517-4HQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517T-3 PN (6ES7517-3TQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1517TF-3 PN (6ES7517-3UQ10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-3 PN (6ES7518-3AT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-3 PN (6ES7518-3FT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518T-3 PN (6ES7518-3TT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU 1518TF-3 PN (6ES7518-3UT10-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S F V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1507S V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S F V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S T V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S TF V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V3 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller CPU 1508S V4 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller Linux V2 vers:all/* (CVE-2025-40943) SIMATIC S7-1500 Software Controller Linux V3 vers:all/* (CVE-2025-40943) SIMATIC S7-PLCSIM Advanced vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) vers:all/* (CVE-2025-40943) SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) vers:all/* (CVE-2025-40943) CVSS Vendor Equipment Vulnerabilities v3 9.6 Siemens Siemens SIMATIC Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40943 Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering a legitimate user to import a specially crafted trace file View CVE Details Affected Products Siemens SIMATIC Vendor: Siemens Product Version: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0), SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0), SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0), SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0), SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0), SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DK03-0AB0), SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0), SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0), SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0), SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DM03-0AB0), SIMATIC ET 200SP CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0), SIMATIC ET 200SP CPU 1514SP-2 PN (6ES7514-2DN03-0AB0), SIMATIC ET 200SP CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0), SIMATIC ET 200SP CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V2 CPUs - Windows OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Industrial OS, SIMATIC ET 200SP Open Controller CPU 1515SP PC3 (incl. SIPLUS variants) V3 CPUs - Windows OS, SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0), SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0), SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0), SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0), SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN (6ES7516-3TP10-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN (6ES7516-3UP10-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0), SIMATIC S7-1500 CPU 1517-3 PN (6ES7517-3AQ10-0AB0), SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN (6ES7517-3FQ10-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0), SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0), SIMATIC S7-1500 CPU 1517H-4 PN (6ES7517-4HQ10-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN (6ES7517-3TQ10-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN (6ES7517-3UQ10-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0), SIMATIC S7-1500 CPU 1518-3 PN (6ES7518-3AT10-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0), SIMATIC S7-1500 CPU 1518F-3 PN (6ES7518-3FT10-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JT10-0AB0), SIMATIC S7-1500 CPU 1518T-3 PN (6ES7518-3TT10-0AB0), SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0), SIMATIC S7-1500 CPU 1518TF-3 PN (6ES7518-3UT10-0AB0), SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0), SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0), SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0), SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0), SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0), SIMATIC S7-1500 Software Controller CPU 1507S F V2, SIMATIC S7-1500 Software Controller CPU 1507S F V3, SIMATIC S7-1500 Software Controller CPU 1507S F V4, SIMATIC S7-1500 Software Controller CPU 1507S V2, SIMATIC S7-1500 Software Controller CPU 1507S V3, SIMATIC S7-1500 Software Controller CPU 1507S V4, SIMATIC S7-1500 Software Controller CPU 1508S F V2, SIMATIC S7-1500 Software Controller CPU 1508S F V3, SIMATIC S7-1500 Software Controller CPU 1508S F V4, SIMATIC S7-1500 Software Controller CPU 1508S T V3, SIMATIC S7-1500 Software Controller CPU 1508S TF V3, SIMATIC S7-1500 Software Controller CPU 1508S V2, SIMATIC S7-1500 Software Controller CPU 1508S V3, SIMATIC S7-1500 Software Controller CPU 1508S V4, SIMATIC S7-1500 Software Controller Linux V2, SIMATIC S7-1500 Software Controller Linux V3, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0), SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0), SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0), SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0), SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0), SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0), SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0), SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0), SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0), SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0), SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0), SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0), SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0), SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0), SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0), SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0), SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0), SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0), SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0), SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0), SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0), SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0), SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0), SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0), SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0), SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0), SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0), SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0), SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0), SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) Product Status: known_affected Remediations Mitigation Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only Mitigation Only upload trusted trace files None available Currently no fix is available Vendor fix Update to V4.1.2 or later version Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.6 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-452276 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-12 2 Initial CISA Republication of Siemens ProductCERT SSA-452276 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-68613 n8n Improper Control of Dynamically-Managed Code Resources Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-68613 n8n Improper Control of Dynamically-Managed Code Resources Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Honeywell IQ4x BMS Controller

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4x BMS Controller are affected: IQ4E >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ412 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4x BMS Controller are affected: IQ4E >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ412 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ422 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ4NC >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ41x >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ3 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQECO >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) CVSS Vendor Equipment Vulnerabilities v3 10 Honeywell Honeywell IQ4x BMS Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Government Services and Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3611 The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration. View CVE Details Affected Products Honeywell IQ4x BMS Controller Vendor: Honeywell Product Version: Honeywell IQ4E: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ412: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ422: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ4NC: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ41x: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQ3: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9, Honeywell IQECO: >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 Product Status: known_affected Remediations Mitigation Honeywell is aware of the issue, but has not released a fix. For more information, contact Honeywell directly. https://www.honeywell.com/us/en/contact. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Gjoko Krstic of Zero Science reported this vulnerability to Honeywell Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Ceragon Siklu MultiHaul and EtherHaul Series

View CSAF Summary Successful exploitation of this vulnerability could result in arbitrary file upload to the target equipment. The following versions of Ceragon Siklu MultiHaul and EtherHaul Series are affected: MultiHaul MH-B100-CCS MultiHaul MH-T200-CCC MultiHaul MH-T200-CNN MultiHaul MH-T201-CNN EtherHaul EH-8010FX EtherHaul EH-500TX EtherHaul EH-600TX EtherHaul EH-614TX EtherHaul EH-700TX EtherHaul EH-710TX…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in arbitrary file upload to the target equipment. The following versions of Ceragon Siklu MultiHaul and EtherHaul Series are affected: MultiHaul MH-B100-CCS MultiHaul MH-T200-CCC MultiHaul MH-T200-CNN MultiHaul MH-T201-CNN EtherHaul EH-8010FX EtherHaul EH-500TX EtherHaul EH-600TX EtherHaul EH-614TX EtherHaul EH-700TX EtherHaul EH-710TX EtherHaul EH-1200TX EtherHaul EH-1200FX EtherHaul EH-2200FX EtherHaul EH-2500FX EtherHaul EH-5500FD CVSS Vendor Equipment Vulnerabilities v3 5.3 Ceragon Ceragon Siklu MultiHaul and EtherHaul Series Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: Israel Vulnerabilities Expand All + CVE-2025-57176 The rfpiped service on TCP port 555 in Ceragon Networks / Siklu Communication EtherHaul and MultiHaul Series microwave antennas allow unauthenticated file uploads to any writable location on the device. File upload packets use weak encryption (metadata only) with file contents transmitted in cleartext. No authentication or path validation is performed. View CVE Details Affected Products Ceragon Siklu MultiHaul and EtherHaul Series Vendor: Ceragon Product Version: Ceragon MultiHaul MH-B100-CCS: <R2.4.0, Ceragon MultiHaul MH-T200-CCC: <R2.4.0, Ceragon MultiHaul MH-T200-CNN: <R2.4.0, Ceragon MultiHaul MH-T201-CNN: <R2.4.0, Ceragon EtherHaul EH-8010FX: <R10.8.1, Ceragon EtherHaul EH-500TX: <R7.7.12, Ceragon EtherHaul EH-600TX: <R7.7.12, Ceragon EtherHaul EH-614TX: <R7.7.12, Ceragon EtherHaul EH-700TX: <R7.7.12, Ceragon EtherHaul EH-710TX: <R7.7.12, Ceragon EtherHaul EH-1200TX: <R7.7.12, Ceragon EtherHaul EH-1200FX: <R7.7.12, Ceragon EtherHaul EH-2200FX: <R7.7.12, Ceragon EtherHaul EH-2500FX: <R7.7.12, Ceragon EtherHaul EH-5500FD: <R7.7.12 Product Status: known_affected Remediations Vendor fix Ceragon has released a software update for the affected models: Vendor fix Affected users should install firmware version R2.4.0 for affected MultiHaul models. Vendor fix Affected users should install firmware version R10.8.1 for the affected EH-8010FX model. Vendor fix Affected users should install firmware version R7.7.12 for other affected EtherHaul models. Mitigation Additionally Ceragon has provided the following security recommendations for mitigating the listed vulnerability. To prevent exposure, management access must follow standard operator security guidelines: Mitigation Management IP addresses must use private subnets (RFC 1918) Mitigation Management networks must be protected by: *-* Firewalls *-* Access Control Lists *-* Network Access Translation / Secure management domains Mitigation Firewalls Mitigation Access Control Lists Mitigation Network Access Translation / Secure management domains Mitigation Public exposure of management IP Addresses is not supported nor recommendedCeragon requests that affected users please verify that all affected radio units: Mitigation Use private management IP addresses only Mitigation Are placed behind internal security controls Mitigation Follow your organization's authentication and access-control policies Mitigation Please visit the Ceragon portal here: https://portal.ceragon.com/ (login required) for further information. Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments CISA discovered a public Proof of Concept (PoC) as authored by semaja22 and reported it to Ceragon Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this (these) vulnerability(ies), such as: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Apeman Cameras

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During Web Page…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-11126 A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-11851 A vulnerability has been found in Apeman ID71 EN75.8.53.20. The affected element is an unknown function of the file /set_alias.cgi. Such manipulation of the argument alias leads to cross site scripting. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N CVE-2025-11852 A vulnerability was found in Apeman ID71 218.53.203.117. The impacted element is an unknown function of the file /onvif/device_service of the component ONVIF Service. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Apeman Cameras Vendor: Apeman Product Version: Apeman ID71: vers:all/* Product Status: known_affected Remediations Mitigation Apeman did not respond to CISAs request for coordination. Users are encouraged to reach out to Apeman for support https://apemans.com/pages/contactus Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments CISA discovered the PoCs (Proof of Concept) as authored by Julio Urena Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Lantronix EDS3000PS and EDS5000

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor Equipment Vulnerabilities v3 9.8 Lantronix Lantronix EDS3000PS and EDS5000 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Authentication Bypass Using an Alternate Path or Channel, Unverified Password Change Background Critical Infrastructure Sectors: Communications, Information Technology, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-67034 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67035 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The SSH Client and SSH Server pages are affected by multiple OS injection vulnerabilities due to missing sanitization of input parameters. An attacker can inject arbitrary commands in delete actions of various objects, such as server keys, users, and known hosts. Commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67036 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenticated attacker can inject arbitrary OS commands that are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67037 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-67038 An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS5000: 2.1.0.0R3 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038 Lantronix recommends users upgrade to EDS5000 version 2.2.0.0R1. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/2538438657/Latest+Firmware+for+the+EDS5000+series+EDS5008+EDS5016+EDS5032. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-67039 An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The authentication on management pages can be bypassed by appending a specific suffix to the URL and by sending an Authorization header that uses "admin" as the username. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-70082 The administrator password can be changed without knowledge of the current password. When chained with an authentication bypass vulnerability, this issue may allow unauthenticated attackers to modify the administrator password. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.7 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N CVE-2025-67041 An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The host parameter of the TFTP client in the Filesystem Browser page is not properly sanitized. This can be exploited to escape from the original command and execute an arbitrary one with root privileges. View CVE Details Affected Products Lantronix EDS3000PS and EDS5000 Vendor: Lantronix Product Version: Lantronix EDS3000PS: 3.1.0.0R2 Product Status: known_affected Remediations Vendor fix For vulnerabilities CVE-2025-67039, CVE-2025-70082, and CVE-2025-67041, Lantronix recommends users upgrade to EDS3000PS version 3.2.0.0R2. The patch can be found here: https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1349189633/Latest+Firmware+for+the+EDS3000PS+series. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Francesco La Spina and Stanislav Dashevskyi of Forescout Technologies reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-22054 Omnissa Workspace ONE Server-Side Request Forgery CVE-2025-26399 SolarWinds Web Help Desk Deserialization of Untrusted Data Vulnerability CVE-2026-1603 Ivanti Endpoint Manager (EPM) Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Browse saved snapshots