[
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-53521\" target=\"_blank\">CVE-2025-53521</a> F5 BIG-IP Remote Code Execution Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 27 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 27 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33634\" target=\"_blank\">CVE-2026-33634</a> Aqua Security Trivy Embedded Malicious Code Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-02",
        "title": "OpenCode Systems OC Messaging and USSD Gateway",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter.</strong></p>\n<p>The following versions of OpenCode Systems OC Messaging and USSD Gateway are affected:</p>\n<ul>\n<li>OC Messaging 6.32.2 (CVE-2025-70614)</li>\n<li>USSD Gateway 6.32.2 (CVE-2025-70614)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.1</td>\n<td>OpenCode Systems</td>\n<td>OpenCode Systems OC Messaging and USSD Gateway</td>\n<td>Improper Access Control</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Bulgaria</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-70614</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>OpenCode Systems Custom Messaging Gateway 6.32.2 contains a web access vulnerability allowing one authenticated user to gain access to another authenticated user's messages via a crafted identifier parameter.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-70614\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OpenCode Systems OC Messaging and USSD Gateway</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OpenCode Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OpenCode Systems OC Messaging: 6.32.2, OpenCode Systems USSD Gateway: 6.32.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The vulnerability was identified by OpenCode Systems on January 5, 2026 and remediated on January 6, 2026 with the release of version 6.33.11.</p>\n<p><strong>Mitigation</strong><br>For more information, contact OpenCode: https://opencode.com/about/contact-us<br><a href=\"https://opencode.com/about/contact-us\">https://opencode.com/about/contact-us</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/284.html\">CWE-284 Improper Access Control</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hussein Amer reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-03",
        "title": "PTC Windchill Product Lifecycle Management",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution.</strong></p>\n<p>The following versions of PTC Windchill Product Lifecycle Management are affected:</p>\n<ul>\n<li>Windchill PDMLink 11.0_M030 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 11.1_M020 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 11.2.1.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 12.0.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 12.1.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.0.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.0.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.1.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 11.0_M030 (CVE-2026-4681)</li>\n<li>FlexPLM 11.1_M020 (CVE-2026-4681)</li>\n<li>FlexPLM 11.2.1.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.0.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.1.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.1.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 13.0.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 13.0.3.0 (CVE-2026-4681)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>PTC</td>\n<td>PTC Windchill Product Lifecycle Management</td>\n<td>Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-4681</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-4681\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>PTC Windchill Product Lifecycle Management</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>PTC</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PTC Windchill PDMLink: 11.0_M030, PTC Windchill PDMLink: 11.1_M020, PTC Windchill PDMLink: 11.2.1.0, PTC Windchill PDMLink: 12.0.2.0, PTC Windchill PDMLink: 12.1.2.0, PTC Windchill PDMLink: 13.0.2.0, PTC Windchill PDMLink: 13.1.0.0, PTC Windchill PDMLink: 13.1.1.0, PTC Windchill PDMLink: 13.1.2.0, PTC Windchill PDMLink: 13.1.3.0, PTC FlexPLM: 11.0_M030, PTC FlexPLM: 11.1_M020, PTC FlexPLM: 11.2.1.0, PTC FlexPLM: 12.0.0.0, PTC FlexPLM: 12.0.2.0, PTC FlexPLM: 12.0.3.0, PTC FlexPLM: 12.1.2.0, PTC FlexPLM: 12.1.3.0, PTC FlexPLM: 13.0.2.0, PTC FlexPLM: 13.0.3.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>PTC is aware of the issue and is actively developing a fix. In the meantime, PTC recommends applying the recommended workaround. Until official patches are available, customers must take urgent steps to safeguard their environments. Specifically: Protect any publicly accessible Windchill systems</p>\n<p><strong>Vendor fix</strong><br>While publicly accessible Windchill and FlexPLM systems are at higher risk and require immediate attention, PTC strongly recommends applying the mitigation steps to all deployments, regardless of Internet exposure</p>\n<p><strong>Vendor fix</strong><br>Apply the same precautions to FlexPLM deployments</p>\n<p><strong>Vendor fix</strong><br>The following Apache and IIS HTTP Server configuration update should be IMMEDIATELY applied to every Windchill or FlexPLM system: Customers using Apache HTTP Server should only follow \"Apache HTTP Server Configuration \u2013 Workaround Steps\" section steps</p>\n<p><strong>Mitigation</strong><br>Customers using Microsoft IIS should only follow \"IIS Configuration - Workaround Steps\" section steps</p>\n<p><strong>Mitigation</strong><br>Please explicitly note that the same mitigation steps must also be applied on File Server / Replica Server configurations where applicable</p>\n<p><strong>Mitigation</strong><br>For Windchill releases prior to 11.0 M030, workarounds may need to be altered to apply to unsupported previous releases</p>\n<p><strong>Mitigation</strong><br>For Apache HTTP Server and IIS configuration workaround steps, please refer to the official advisory at:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability.<br><a href=\"https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability\">https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability</a></p>\n<p><strong>Mitigation</strong><br>If immediate remediation is not feasible, additional guidance and remediation options are available:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability.<br><a href=\"https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability\">https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous source reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Republication of PTC's CS466318</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-01",
        "title": "WAGO GmbH & Co. KG Industrial Managed Switches",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.</strong></p>\n<p>The following versions of WAGO GmbH &amp; Co. KG Industrial Managed Switches are affected:</p>\n<ul>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S1 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>WAGO</td>\n<td>WAGO GmbH &amp; Co. KG Industrial Managed Switches</td>\n<td>Hidden Functionality</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-3587</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3587\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>WAGO GmbH &amp; Co. KG Industrial Managed Switches</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>WAGO</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware versions prior to V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware versions prior to V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware versions prior to V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware versions prior to V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware version V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware version V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware version V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-001, WAGO WAGO Firmware version V1.2.1.S1: WAGO_Hardware_852-1813/010-001</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>WAGO has identified the following specific workarounds and mitigations users can apply to reduce risk: Product Group: WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1813/010-001, WAGO Firmware installed on WAGO Hardware 852-1813/010-001): Please update your devices to the specified fixed Firmware version.</p>\n<p><strong>Mitigation</strong><br>Lean Managed Switch 852-1812, Lean Managed Switch 852-1813, Lean Managed Switch 852-1813/000-001, Lean Managed Switch 852-1816, Lean Managed Switch 852-1812/010-000, Lean Managed Switch 852-1813/010-000, Lean Managed Switch 852-1816/010-000, Lean Managed Switch 852-1813/010-001: To eliminate the attack vector deactivate ssh and telnet on the device.</p>\n<p><strong>Mitigation</strong><br>Industrial Managed Switch 852-303, Industrial Managed Switch 852-1305, Industrial Managed Switch 852-1305/000-001, Industrial Managed Switch 852-1505/000-001, Industrial Managed Switch 852-1505, Industrial Managed Switch 852-602, Industrial Managed Switch 852-603, Industrial Managed Switch 852-1605: To reduce the attack vector deactivate ssh and telnet on the devices. This ensures that the CLI is only accessible locally via RS232.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed: Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.3.S1 installed on Lean Managed Switch 852-1813/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.8.S1 installed on Industrial Managed Switch 852-303 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1505/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.1.9.S1 installed on Industrial Managed Switch 852-1505 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-602 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-603 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.5.S1 installed on Industrial Managed Switch 852-1605 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://www.wago.com/de-en/automation-technology/psirt\">https://www.wago.com/de-en/automation-technology/psirt</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://certvde.com/en/advisories/VDE-2026-020\">https://certvde.com/en/advisories/VDE-2026-020</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json\">https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/912.html\">CWE-912 Hidden Functionality</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CERT@VDE coordination reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Republication of WAGO GmbH &amp; Co. KG VDE-2026-020</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/25/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/25/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33017\" target=\"_blank\">CVE-2026-33017</a> Langflow Code Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 25 Mar 26 12:00:00 +0000",
        "last_updated": "Wed, 25 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-01",
        "title": "Pharos Controls Mosaic Show Controller",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges.</strong></p>\n<p>The following versions of Pharos Controls Mosaic Show Controller are affected:</p>\n<ul>\n<li>Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Pharos Controls</td>\n<td>Pharos Controls Mosaic Show Controller</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United Kingdom</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-2417</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-2417\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Pharos Controls Mosaic Show Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Pharos Controls</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Pharos Controls Mosaic Show Controller Firmware: 2.15.3</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>James Tully reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-03",
        "title": "Schneider Electric Plant iT/Brewmaxx",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution.</strong></p>\n<p>The following versions of Schneider Electric Plant iT/Brewmaxx are affected:</p>\n<ul>\n<li>Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.9</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Plant iT/Brewmaxx</td>\n<td>Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Critical Manufacturing, Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-49844</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-49844\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46817</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46817\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46818</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46818\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46819</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46819\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Republication of SEVD-2026-013-01</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-02",
        "title": "Schneider Electric EcoStruxure Foxboro DCS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure Foxboro DCS Control Software on Foxboro DCS workstations and servers. Control Core Services and all runtime software, like FCPs, FDCs, and FBMs, are not affected. The EcoStruxure Foxboro DCS ([https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/)) product is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediation provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected:</p>\n<ul>\n<li>EcoStruxure Foxboro DCS vers:generic/</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Foxboro DCS</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1286</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1286\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Foxboro DCS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Foxboro DCS versions prior to CS8.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version CS 8.1 of EcoStruxure Foxboro DCS includes a fix for this vulnerability and is available through [https://buyautomation.se.com/](https://buyautomation.se.com/) CS 8.1 requires FX-V3 licenses, standard upgrade procedures apply. A reboot is required for workstations and servers. Depending on the existing system version, online upgrade without production interruption might be possible. Schneider Electric recommends you work with your local field service representative or technical service consultant for further information.&nbsp;<br><a href=\"https://buyautomation.se.com/\">https://buyautomation.se.com/</a></p>\n<p><strong>Mitigation</strong><br>If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The vulnerability is attacked with manipulated data from external sources to the DCS computers. Examples for these are: * Configuration taglists * DirectAccess Scripts * Any partial or full Galaxy backups * Library files * Code snippets * ASCII files of any sort * Generally, any file getting from outside the DCS computer on a DCS computer. Only use data from trusted sources, check for correct file name endings on data files, check for reasonable file sizes for any files coming to the system, and check structured data for any fields or columns which might be unexpected. Check for unusual manipulations of data within data files and reject files containing unexpected data or structures. Use secure communication channels and encrypt communications when communicating outside the site network. Avoid and ban removable media (e.g. USB sticks or drives) Minimize count of users with engineering or administrative rights to DCS computers and ensure all interactions on DCS computers are executed with minimal user access rights. Consequently, isolating Foxboro DCS computers will help minimizing the risk of this vulnerability being exploited.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-13</td>\n<td>2</td>\n<td>Updated remediation and mitigations section.</td>\n</tr>\n<tr>\n<td>2026-03-24</td>\n<td>3</td>\n<td>Initial CISA Republication of Schneider Electric Security Notification SEVD-2026-069-03</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-083-01",
        "title": "Grassroots DICOM (GDCM)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-083-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-083-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to send a specially crafted file, and when parsed, could result in a denial-of-service condition.</strong></p>\n<p>The following versions of Grassroots DICOM (GDCM) are affected:</p>\n<ul>\n<li>Grassroots DICOM (GDCM) 3.2.2 (CVE-2026-3650)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Grassroots</td>\n<td>Grassroots DICOM (GDCM)</td>\n<td>Missing Release of Memory after Effective Lifetime</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-3650</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A memory leak exists in the Grassroots DICOM library (GDCM). The bug occurs when parsing malformed DICOM files with non-standard VR types in file meta information. The vulnerability leads to vast memory allocations and resource depletion, triggering a denial-of-service condition. A maliciously crafted file can fill the heap in a single read operation without properly releasing it.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3650\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Grassroots DICOM (GDCM)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Grassroots</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Grassroots Grassroots DICOM (GDCM): 3.2.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer of Grassroots DICOM (GDCM) has not responded to requests to work with CISA to mitigate this vulnerability. For update information refer to the software page on SourceForge.</p>\n<p><strong>Mitigation</strong><br>https://sourceforge.net/projects/gdcm/.<br><a href=\"https://sourceforge.net/projects/gdcm/\">https://sourceforge.net/projects/gdcm/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Volodymyr Bihunenko, Mykyta Mudryi, and Markiian Chaklosh of ARIMLABS reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Publication.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/20/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Five Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/20/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added five new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-31277\" target=\"_blank\">CVE-2025-31277</a> Apple Multiple Products Buffer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-32432\" target=\"_blank\">CVE-2025-32432</a> Craft CMS Code Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-43510\" target=\"_blank\">CVE-2025-43510</a> Apple Multiple Products Improper Locking Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-43520\" target=\"_blank\">CVE-2025-43520</a> Apple Multiple Products Classic Buffer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-54068\" target=\"_blank\">CVE-2025-54068</a> Laravel Livewire Code Injection Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 20 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 20 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-target-commercial-messaging-application-accounts",
        "title": "Russian Intelligence Services Target Commercial Messaging Application Accounts",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-target-commercial-messaging-application-accounts",
        "summary": "<p>CISA and the Federal Bureau of Investigation released a <a href=\"https://www.ic3.gov/PSA/2026/PSA260320\" target=\"_blank\">Public Service Announcement (PSA)</a> warning about ongoing phishing campaigns by cyber actors associated with the Russian Intelligence Services targeting commercial messaging applications (CMAs). These campaigns aim to bypass encryption to compromise to individual user accounts with targets including current and former U.S. government officials, military personnel, political figures, and journalists.&nbsp;&nbsp;</p>\n<p>Evidence shows that cyber actors have been able to compromise individual CMA accounts, but not encryption of the applications themselves. The actors\u2019 global campaigns have resulted in unauthorized access to thousands of individual CMA accounts to view the victims\u2019 messages and contact lists, send messages, and conduct additional phishing against other CMA accounts. &nbsp;</p>\n<p>CISA and FBI urge CMA users to review the PSA, follow recommended cybersecurity practices, and remain vigilant for suspicious activity.</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 20 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 20 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-06",
        "title": "CTEK Chargeportal",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.</strong></p>\n<p>The following versions of CTEK Chargeportal are affected:</p>\n<ul>\n<li>Chargeportal vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>CTEK</td>\n<td>CTEK Chargeportal</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Sweden</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25192</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25192\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31904</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31904\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27649</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27649\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-28204</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Charging station authentication identifiers are publicly accessible via web-based mapping platforms.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-28204\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine, Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-02",
        "title": "Schneider Electric Modicon Controllers M241, M251, M258, and LMC058",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser.</strong></p>\n<p>The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected:</p>\n<ul>\n<li>Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241</li>\n<li>Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251</li>\n<li>Modicon Controllers M258 all firmware versions Modicon_Controllers_M258</li>\n<li>Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.4</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Modicon Controllers M241, M251, M258, and LMC058</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13902</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13902\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Modicon Controllers M241, M251, M258, and LMC058</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000003059/\">https://www.se.com/ww/en/download/document/EIO0000003059/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/us/en/download/document/EIO0000003089/\">https://www.se.com/us/en/download/document/EIO0000003089/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER</a></p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric</li>\n<li>Schneider Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-08",
        "title": "Automated Logic WebCTRL Premium Server",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to read, intercept, or modify communications.</strong></p>\n<p>The following versions of Automated Logic WebCTRL Premium Server are affected:</p>\n<ul>\n<li>WebCTRL Premium Server</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Automated Logic</td>\n<td>Automated Logic WebCTRL Premium Server</td>\n<td>Multiple Binds to the Same Port, Authentication Bypass by Spoofing, Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25086</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Under certain conditions, an attacker could bind to the same port used by WebCTRL. This could allow the attacker to craft and send malicious packets and impersonate the WebCTRL service without requiring code injection into the WebCTRL software.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25086\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/605.html\">CWE-605 Multiple Binds to the Same Port</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32666</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebCTRL systems that communicate over BACnet inherit the protocol's lack of network layer authentication. WebCTRL does not implement additional validation of BACnet traffic so an attacker with network access could spoof BACnet packets directed at either the WebCTRL server or associated AutomatedLogic controllers. Spoofed packets may be processed as legitimate.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32666\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/290.html\">CWE-290 Authentication Bypass by Spoofing</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-24060</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Service information is not encrypted when transmitted as BACnet packets over the wire, and can be sniffed, intercepted, and modified by an attacker. Valuable information such as the File Start Position and File Data can be sniffed from network traffic using Wireshark's BACnet dissector filter. The proprietary format used by WebCTRL to receive updates from the PLC can also be sniffed and reverse engineered.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24060\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jonathan Lee, Thuy D. Nguyen and Neil C. Rowe of the Naval Postgraduate School reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/19/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/19/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20131\" target=\"_blank\">CVE-2026-20131</a> Cisco Secure Firewall Management Center (FMC) Software and Cisco Security Cloud Control (SCC) Firewall Management Deserialization of Untrusted Data Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-01",
        "title": "Schneider Electric Modicon M241, M251, and M262",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product.</strong></p>\n<p>The following versions of Schneider Electric Modicon M241, M251, and M262 are affected:</p>\n<ul>\n<li>Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241</li>\n<li>Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251</li>\n<li>Modicon M262 versions prior to 5.4.10.12 Modicon_Controller_M262</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Modicon M241, M251, and M262</td>\n<td>Improper Resource Shutdown or Release</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13901</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13901\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Modicon M241, M251, and M262</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon M262 versions prior to 5.4.10.12: Modicon_Controller_M262</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure\u2122 Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure\u2122 Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-01 Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf. Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-01.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf</a></p>\n<p><strong>Mitigation</strong><br>All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Filter ports and IP through the embedded firewall. Use encrypted communication links. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/404.html\">CWE-404 Improper Resource Shutdown or Release</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric</li>\n<li>Schneider Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-069-01</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-04",
        "title": "Schneider Electric EcoStruxure PME and EPO",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure PME and EPO are affected:</p>\n<ul>\n<li>EcoStruxure Power Monitoring Expert (PME) 2022 &lt;=2022</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023_R2</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024_R2</li>\n<li>EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module &lt;=2022</li>\n<li>EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module 2024</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023_R2_Hotfix_282807</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024_R2_Hotfix_279338__2024R2</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure PME and EPO</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health, Information Technology, Critical Manufacturing, Commercial Facilities, Energy, Transportation Systems, Government Services and Facilities, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11739</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A deserialization of untrusted data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11739\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure PME and EPO</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Power Monitoring Expert (PME) Version 2022 and prior, EcoStruxure Power Monitoring Expert (PME) Version 2023, EcoStruxure Power Monitoring Expert (PME) Version 2023 R2, EcoStruxure Power Monitoring Expert (PME) Version 2024, EcoStruxure Power Monitoring Expert (PME) Version 2024 R2, EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module Version 2022 and prior, EcoStruxure Power Operation (EPO) 2024 with Advanced Reporting and Dashboards Module Version 2024</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Hotfix_279338_Release_2024R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this hotfix. No reboot required.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2024 R3. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>Vendor fix</strong><br>Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this hotfix. No reboot required.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>No fix planned</strong><br>EcoStruxure Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. \u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments\u2022 Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.&nbsp;<br><a href=\"https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm\">https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm</a></p>\n<p><strong>No fix planned</strong><br>EcoStruxure Power Operation (EPO) 2022 version and EcoStruxure Power Monitoring Expert (PME) 2022 has reached its end of life and is no longer supported. \u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments\u2022 Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.&nbsp;<br><a href=\"https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm\">https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Note</h2>\n<p>EcoStruxure Power Operation 2022 with Advanced Reporting AND EcoStruxure Power Operation 2024 with Advanced Reporting utilizes EcoStruxure Power Monitoring Expert. You must update EcoStruxure Power Monitoring Expert separately from EcoStruxure Power Operation and apply the appropriate update for Power Monitoring Expert as described above.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-06 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-19</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric SEVD-2026-069-06 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-03",
        "title": "Schneider Electric EcoStruxure Automation Expert",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure\u2122 Automation Expert product. The EcoStruxure\u2122 Automation Expert product is plant automation software designed for digital control systems in discrete, hybrid and continuous industrial processes. A totally integrated automation solution designed to enhance your flexibility, efficiency and scalability. Failure to apply the remediation provided below may risk execution of arbitrary commands on the engineering workstation, which could result in a potential compromise of full system.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Automation Expert are affected:</p>\n<ul>\n<li>EcoStruxure\u2122 Automation Expert vers:intdot/&lt;25.0.1, 25.0.1</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.2</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Automation Expert</td>\n<td>Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-2273</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-2273\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Automation Expert</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure\u2122 Automation Expert Versions prior to v25.0.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version v25.0.1 of EcoStruxure\u2122 Automation Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/<br><a href=\"https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/\">https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/</a></p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Solution and archive files must be stored within the user\u2019s home directory or in any location protected by appropriate Windows file\u2011system access controls to prevent unauthorized access in multi\u2011user environments. Users who choose to store files outside their home directory are responsible for applying restrictive Windows permissions to secure those locations. Before opening any solution or archive file, users are required to verify its authenticity and ensure that it has not been modified by unauthorized users. For detailed mitigation steps, refer to the User Manual - https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help<br><a href=\"https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help\">https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n<li>Raffaele Bova of Nozomi Networks reported this vulnerability to Schneider Electric.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-19</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-069-04 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "title": "Mitsubishi Electric CNC Series",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products.</strong></p>\n<p>The following versions of Mitsubishi Electric CNC Series are affected:</p>\n<ul>\n<li>M800VW (BND-2051W000) &lt;=BB</li>\n<li>M800VS (BND-2052W000) &lt;=BB</li>\n<li>M80V (BND-2053W000) &lt;=BB</li>\n<li>M80VW (BND-2054W000) &lt;=BB</li>\n<li>M800W (BND-2005W000) &lt;=FM</li>\n<li>M800S (BND-2006W000) &lt;=FM</li>\n<li>M80 (BND-2007W000) &lt;=FM</li>\n<li>M80W (BND-2008W000) &lt;=FM</li>\n<li>E80 (BND-2009W000) &lt;=FM</li>\n<li>C80 (BND-2036W000) vers:all/*</li>\n<li>M750VW (BND-1015W002) vers:all/*</li>\n<li>M730VW (BND-1015W000) vers:all/*</li>\n<li>M720VW (BND-1015W000) vers:all/*</li>\n<li>M750VS (BND-1012W002) vers:all/*</li>\n<li>M730VS (BND-1012W000-**) vers:all/*</li>\n<li>M720VS (BND-1012W000) vers:all/*</li>\n<li>M70V (BND-1018W000) vers:all/*</li>\n<li>E70 (BND-1022W000) vers:all/*</li>\n<li>NC Trainer2 (BND-1802W000) vers:all/*</li>\n<li>NC Trainer2 plus (BND-1803W000) vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.9</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric CNC Series</td>\n<td>Improper Validation of Specified Index, Position, or Offset in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-2399</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2399\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric CNC Series</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric M800VW (BND-2051W000): &lt;=BB, Mitsubishi Electric M800VS (BND-2052W000): &lt;=BB, Mitsubishi Electric M80V (BND-2053W000): &lt;=BB, Mitsubishi Electric M80VW (BND-2054W000): &lt;=BB, Mitsubishi Electric M800W (BND-2005W000): &lt;=FM, Mitsubishi Electric M800S (BND-2006W000): &lt;=FM, Mitsubishi Electric M80 (BND-2007W000): &lt;=FM, Mitsubishi Electric M80W (BND-2008W000): &lt;=FM, Mitsubishi Electric E80 (BND-2009W000): &lt;=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): vers:all/*, Mitsubishi Electric M730VW (BND-1015W000): vers:all/*, Mitsubishi Electric M720VW (BND-1015W000): vers:all/*, Mitsubishi Electric M750VS (BND-1012W002): vers:all/*, Mitsubishi Electric M730VS (BND-1012W000): vers:all/*, Mitsubishi Electric M720VS (BND-1012W000): vers:all/*, Mitsubishi Electric M70V (BND-1018W000): vers:all/*, Mitsubishi Electric E70 (BND-1022W000): vers:all/*, Mitsubishi Electric NC Trainer2 (BND-1802W000): vers:all/*, Mitsubishi Electric NC Trainer2 plus (BND-1803W000): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW(BND-2051W000), M800VS(BND-2052W000), M80V(BND-2053W000), and M80VW(BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (FN or later) for Mitsubishi Electric M800W(BND-2005W000), M800S(BND-2006W000), M80(BND-2007W000), M80W(BND-2008W000), and E80(BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product: M800V/M80V Series Instruction Manual \"16. Appendix 3 IP Address Filter Setting Function\", M800/M80/E80 Series Instruction Manual \"15. Appendix 2 IP Address Filter Setting Function\"</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information, see Mitsubishi Electric 2025-022. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf&nbsp;<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1285.html\">CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of CISA V20250121-001#02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial CISA Republication of&nbsp;Mitsubishi Electric security advisory 2025-022</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-07",
        "title": "IGL-Technologies eParking.fi",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.</strong></p>\n<p>The following versions of IGL-Technologies eParking.fi are affected:</p>\n<ul>\n<li>eParking.fi vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>IGL-Technologies</td>\n<td>IGL-Technologies eParking.fi</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Finland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-29796</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-29796\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.<br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31903</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31903\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31926</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Charging station authentication identifiers are publicly accessible via web-based mapping platforms.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31926\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-urges-endpoint-management-system-hardening-after-cyberattack-against-us-organization",
        "title": "CISA Urges Endpoint Management System Hardening After Cyberattack Against US Organization",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-urges-endpoint-management-system-hardening-after-cyberattack-against-us-organization",
        "summary": "<p>CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.<a href=\"#note1\"><sup>1</sup></a> To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions.</p>\n<p>To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft\u2019s newly released <a href=\"https://techcommunity.microsoft.com/blog/intunecustomersuccess/best-practices-for-securing-microsoft-intune/4502117\" target=\"_blank\">best practices for securing Microsoft Intune</a>; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software:&nbsp;</p>\n<ul>\n<li><strong>Use principles of least privilege when designing administrative roles</strong>.\n<ul>\n<li>Leverage Microsoft Intune\u2019s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations\u2014permissions include what actions the role can take, and what users and devices it can apply that action to.</li>\n</ul>\n</li>\n<li><strong>Enforce phishing-resistant multi-factor authentication (MFA) and privileged access hygiene</strong>.\n<ul>\n<li>Use Microsoft Entra ID capabilities (including Conditional Access, MFA, risk signals, and privileged access controls) to block unauthorized access to privileged actions in Microsoft Intune.</li>\n</ul>\n</li>\n<li><strong>Configure access policies to require </strong><a href=\"https://learn.microsoft.com/en-us/intune/intune-service/fundamentals/multi-admin-approval\" target=\"_blank\"><strong>Multi Admin Approval in Microsoft Intune</strong></a>.\n<ul>\n<li>Set up policies that require a second administrative account\u2019s approval to allow changes to sensitive or high-impact actions (such as device wiping), applications, scripts, RBAC, configurations, etc. &nbsp;</li>\n</ul>\n</li>\n</ul>\n<p>Additionally, CISA recommends reviewing the following resources to strengthen defenses against similar malicious cyber activity:</p>\n<ul>\n<li>Microsoft resources:\n<ul>\n<li>For recommendations on securing Microsoft Intune, see <a href=\"https://techcommunity.microsoft.com/blog/intunecustomersuccess/best-practices-for-securing-microsoft-intune/4502117\" target=\"_blank\">Best practices for securing Microsoft Intune</a>.</li>\n<li>For guidance on implementing Multi Admin Approval in Microsoft Intune, see <a href=\"https://learn.microsoft.com/en-us/intune/intune-service/fundamentals/multi-admin-approval\" target=\"_blank\">Use Access policies to implement Multi Admin Approval</a>.</li>\n<li>For recommendations on configuring Microsoft Intune using zero trust principles, see <a href=\"https://learn.microsoft.com/en-us/intune/intune-service/protect/zero-trust-configure-security?toc=/security/zero-trust/assessment/toc.json&amp;bc=/security/zero-trust/assessment/toc.json\" target=\"_blank\">Configure Microsoft Intune for increased security</a>.</li>\n<li>For guidance on implementing Microsoft Intune RBAC policies, see <a href=\"https://learn.microsoft.com/en-us/intune/intune-service/fundamentals/role-based-access-control\" target=\"_blank\">Role-based access control (RBAC) with Microsoft Intune</a>.</li>\n<li>For guidance on deploying Privileged Identity Management (PIM) across Microsoft Intune, Entra ID, and other Microsoft software, see <a href=\"https://learn.microsoft.com/en-us/entra/id-governance/privileged-identity-management/pim-deployment-plan\" target=\"_blank\">Plan a Privileged Identity Management deployment</a>. &nbsp;</li>\n</ul>\n</li>\n<li>CISA resources:\n<ul>\n<li>For guidance on implementing phishing-resistant multifactor authentication (MFA), see <a href=\"https://www.cisa.gov/sites/default/files/2023-01/fact-sheet-implementing-phishing-resistant-mfa-508c.pdf\">Implementing Phishing-Resistant MFA</a>.&nbsp;</li>\n</ul>\n</li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. &nbsp;</p>\n<h2><strong>Acknowledgements</strong></h2>\n<p>Microsoft and Stryker contributed to this alert.&nbsp;</p>\n<h2><strong>Notes </strong><a class=\"ck-anchor\" id=\"note1\"></a></h2>\n<p>1 For updates from Stryker on the incident, see \u201cCustomer Updates: Stryker Network Disruption,\u201d Stryker, last modified March 15, 2026, <a href=\"https://www.stryker.com/us/en/about/news/2026/a-message-to-our-customers-03-2026.html\" target=\"_blank\">https://www.stryker.com/us/en/about/news/2026/a-message-to-our-customers-03-2026.html</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 18 Mar 26 12:00:00 +0000",
        "last_updated": "Wed, 18 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-adds-one-known-exploited-vulnerability-catalog-0",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-adds-one-known-exploited-vulnerability-catalog-0",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20963\" target=\"_blank\">CVE-2026-20963</a> Microsoft SharePoint Deserialization of Untrusted Data Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 18 Mar 26 12:00:00 +0000",
        "last_updated": "Wed, 18 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-66376\" target=\"_blank\">CVE-2025-66376</a> Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 18 Mar 26 12:00:00 +0000",
        "last_updated": "Wed, 18 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-04",
        "title": "Siemens SICAM SIAPP SDK",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-076-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens has released a new version for SICAM SIAPP SDK and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SICAM SIAPP SDK are affected:</p>\n<ul>\n<li>SICAM SIAPP SDK vers:intdot/&lt;2.1.7</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.4</td>\n<td>Siemens</td>\n<td>Siemens SICAM SIAPP SDK</td>\n<td>Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25569</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25569\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25570</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25570\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25571</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The SICAM SIAPP SDK client component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25571\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/130.html\">CWE-130 Improper Handling of Length Parameter Inconsistency</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25572</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25572\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/130.html\">CWE-130 Improper Handling of Length Parameter Inconsistency</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25573</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25573\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/73.html\">CWE-73 External Control of File Name or Path</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25605</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25605\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM SIAPP SDK</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SICAM SIAPP SDK</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.1.7 or later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/73.html\">CWE-73 External Control of File Name or Path</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n<li>Maxime Rossi Bellom of Secmate reported these vulnerabilities to Siemens.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-903736 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-03-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-903736 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 17 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 17 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-01",
        "title": "CODESYS in Festo Automation Suite",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-076-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>3. TECHNICAL DETAILS</strong></p>\n<p>The following versions of CODESYS in Festo Automation Suite are affected:</p>\n<ul>\n<li>FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* </li>\n<li>FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* </li>\n<li>FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* </li>\n<li>FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>FESTO, CODESYS</td>\n<td>CODESYS in Festo Automation Suite</td>\n<td>Direct Request ('Forced Browsing'), Untrusted Search Path, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Recursion, Improper Access Control, Use of Insufficiently Random Values, Improper Restriction of Communication Channel to Intended Endpoints, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), NULL Pointer Dereference, Stack-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Incorrect Permission Assignment for Critical Resource, Improper Handling of Exceptional Conditions, Exposure of Resource to Wrong Sphere, Allocation of Resources Without Limits or Throttling, Use of a Broken or Risky Cryptographic Algorithm, Out-of-bounds Write, Weak Password Recovery Mechanism for Forgotten Password, Improper Privilege Management, Use of Password Hash With Insufficient Computational Effort, Buffer Access with Incorrect Length Value, Improper Input Validation, Improper Verification of Cryptographic Signature, Inadequate Encryption Strength, Origin Validation Error, Missing Release of Memory after Effective Lifetime, Improper Resource Shutdown or Release, Deserialization of Untrusted Data, Path Equivalence: '//multiple/leading/slash', Insufficient Verification of Data Authenticity, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Out-of-bounds Read, Failure to Sanitize Special Elements into a Different Plane (Special Element Injection), Use of Out-of-range Pointer Offset, Improper Neutralization of Script in Attributes of IMG Tags in a Web Page, Files or Directories Accessible to External Parties, Untrusted Pointer Dereference, Path Traversal: '....' (Multiple Dot), ASP.NET Misconfiguration: Missing Custom Error Page, Uncontrolled Resource Consumption, Unprotected Transport of Credentials, Initialization of a Resource with an Insecure Default, Heap-based Buffer Overflow, Unexpected Sign Extension, Buffer Over-read, Uncontrolled Search Path Element, Improper Verification of Source of a Communication Channel, Improper Restriction of Excessive Authentication Attempts, Use After Free, ASP.NET Misconfiguration: Password in Configuration File, Improper Check for Unusual or Exceptional Conditions, Observable Discrepancy, Incorrect Default Permissions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-2595</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2595\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/425.html\">CWE-425 Direct Request ('Forced Browsing')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2010-5250</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory.NOTE: some of these details are obtained from third party information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2010-5250\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/426.html\">CWE-426 Untrusted Search Path</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-3735</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-3735\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-0739</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-0739\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/674.html\">CWE-674 Uncontrolled Recursion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-10612</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-10612\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/284.html\">CWE-284 Improper Access Control</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-20025</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-20025\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/330.html\">CWE-330 Use of Insufficiently Random Values</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-20026</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-20026\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/923.html\">CWE-923 Improper Restriction of Communication Channel to Intended Endpoints</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13532</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13532\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13538</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13538\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13542</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13542\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13548</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13548\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-18858</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-18858\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-19789</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-19789\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-5105</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-5105\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9008</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9008\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/732.html\">CWE-732 Incorrect Permission Assignment for Critical Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9009</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9009\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/755.html\">CWE-755 Improper Handling of Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9010</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9010\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/284.html\">CWE-284 Improper Access Control</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9011</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9011\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/668.html\">CWE-668 Exposure of Resource to Wrong Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9012</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9012\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-9013</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-9013\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/327.html\">CWE-327 Use of a Broken or Risky Cryptographic Algorithm</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-10245</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-10245\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-12067</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user's password may be changed by an attacker without knowledge of the current password.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-12067\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/640.html\">CWE-640 Weak Password Recovery Mechanism for Forgotten Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-12068</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-12068\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/269.html\">CWE-269 Improper Privilege Management</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-12069</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-12069\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/916.html\">CWE-916 Use of Password Hash With Insufficient Computational Effort</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-14509</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-14509\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/805.html\">CWE-805 Buffer Access with Incorrect Length Value</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-14513</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-14513\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-14515</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-14515\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/347.html\">CWE-347 Improper Verification of Cryptographic Signature</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-14517</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-14517\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:<br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:<br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/326.html\">CWE-326 Inadequate Encryption Strength</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-14519</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-14519\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/346.html\">CWE-346 Origin Validation Error</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-15806</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-15806\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-16233</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-16233\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/404.html\">CWE-404 Improper Resource Shutdown or Release</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-7052</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-7052\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21863</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21863\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21864</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21864\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/50.html\">CWE-50 Path Equivalence: '//multiple/leading/slash'</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21865</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21865\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21866</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21866\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21867</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21867\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/50.html\">CWE-50 Path Equivalence: '//multiple/leading/slash'</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21868</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21868\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/50.html\">CWE-50 Path Equivalence: '//multiple/leading/slash'</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-21869</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-21869\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-29239</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-29239\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/345.html\">CWE-345 Insufficient Verification of Data Authenticity</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-29240</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-29240\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/345.html\">CWE-345 Insufficient Verification of Data Authenticity</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-29241</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-29241\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-29242</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-29242\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-30186</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-30186\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-30187</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-30187\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-30188</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-30188\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-30190</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-30190\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-30195</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-30195\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-33485</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-33485\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-33486</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-33486\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/755.html\">CWE-755 Improper Handling of Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-34593</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-34593\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/75.html\">CWE-75 Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-34595</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-34595\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/823.html\">CWE-823 Use of Out-of-range Pointer Offset</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-34596</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-34596\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/82.html\">CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-36763</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-36763\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-36764</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-36764\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-36765</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-36765\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-1965</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-1965\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/755.html\">CWE-755 Improper Handling of Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-1989</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-1989\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22508</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22508\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22513</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22513\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22514</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22514\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/822.html\">CWE-822 Untrusted Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22515</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22515\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/668.html\">CWE-668 Exposure of Resource to Wrong Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22516</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22516\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/732.html\">CWE-732 Incorrect Permission Assignment for Critical Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22517</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22517\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/33.html\">CWE-33 Path Traversal: '....' (Multiple Dot)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-22519</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-22519\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/12.html\">CWE-12 ASP.NET Misconfiguration: Missing Custom Error Page</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-30791</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-30791\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-30792</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-30792\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/400.html\">CWE-400 Uncontrolled Resource Consumption</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31805</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-31805\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/523.html\">CWE-523 Unprotected Transport of Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31806</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-31806\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1188.html\">CWE-1188 Initialization of a Resource with an Insecure Default</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32136</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32136\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/82.html\">CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32137</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32137\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32138</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32138\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/194.html\">CWE-194 Unexpected Sign Extension</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32139</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32139\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32140</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32140\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32141</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32141\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/126.html\">CWE-126 Buffer Over-read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32142</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32142\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/823.html\">CWE-823 Use of Out-of-range Pointer Offset</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-32143</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-32143\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4046</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-4046\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4048</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-4048\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/326.html\">CWE-326 Inadequate Encryption Strength</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4224</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-4224\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1188.html\">CWE-1188 Initialization of a Resource with an Insecure Default</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47378</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47378\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47379</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47379\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47380</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker may use a stack basedout-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47380\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47381</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47381\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47383</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47383\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47384</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47384\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47387</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47387\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47388</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47388\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47389</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47389\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47390</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47390\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47391</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47391\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47392</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead to a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47392\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47393</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47393\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3662</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context .</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-3662\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/427.html\">CWE-427 Uncontrolled Search Path Element</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-3663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/940.html\">CWE-940 Improper Verification of Source of a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3669</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-3669\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.3</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3670</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In CODESYS Development System 3.5.9.0 to 3.5.17.0 and CODESYS Scripting 4.0.0.0 to 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-3670\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/668.html\">CWE-668 Exposure of Resource to Wrong Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37545</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37545\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37546</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37546\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37547</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37547\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37548</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37548\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37549</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37549\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37550</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37550\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37551</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37551\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37552</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37552\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37553</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37553\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37554</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37554\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37555</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37555\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37556</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37556\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37557</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37557\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37558</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37558\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-37559</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-37559\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-3935</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-3935\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-49675</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-49675\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-49676</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-49676\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-6357</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-6357\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-5000</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-5000\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/13.html\">CWE-13 ASP.NET Misconfiguration: Password in Configuration File</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-8175</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-8175\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/754.html\">CWE-754 Improper Check for Unusual or Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-0694</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-0694\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-1468</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-1468\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/203.html\">CWE-203 Observable Discrepancy</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-41658</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-41658\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-41659</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-41659\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/732.html\">CWE-732 Incorrect Permission Assignment for Critical Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-11023</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing option elements from untrusted sources - even after sanitizing it - to one of jQuery's DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-11023\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-47382</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-47382\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CODESYS in Festo Automation Suite</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>FESTO, CODESYS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Mitigation</strong><br>Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed:</p>\n<p><strong>Mitigation</strong><br>CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json\">https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Festo SE &amp; Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML.<br><a href=\"https://certvde.com/en/advisories/VDE-2025-108\">https://certvde.com/en/advisories/VDE-2025-108</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CERT@VDE reported this vulnerability to Festo</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-17</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-17</td>\n<td>1</td>\n<td>Initial Republication of Festo SE &amp; Co. KG FSA-202601</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 17 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 17 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-02",
        "title": "Schneider Electric SCADAPack and RemoteConnect",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-076-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its SCADAPack\u2122 x70 RTU products. The SCADAPack\u2122 47xi, SCADAPack\u2122 47x and SCADAPack\u2122 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.</strong></p>\n<p>The following versions of Schneider Electric SCADAPack and RemoteConnect are affected:</p>\n<ul>\n<li>SCADAPack\u2122 vers:generic/</li>\n<li>SCADAPack\u2122 firmware vers:intdot/&lt;9.12.2, 9.12.2, vers:intdot/&lt;9.12.2, 9.12.2 ()</li>\n<li>RemoteConnect vers:generic/</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric SCADAPack and RemoteConnect</td>\n<td>Improper Check for Unusual or Exceptional Conditions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0667</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality &amp; integrity when communicating over the Modbus TCP protocol.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-0667\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric SCADAPack and RemoteConnect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCADAPack\u2122 57x All Versions, RemoteConnect Versions prior to R3.4.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version R3.4.2 (Firmware version 9.12.2) of SCADAPack\u2122 47x and SCADAPack\u2122 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/</p>\n<p><strong>Vendor fix</strong><br>Version R3.4.2 of RemoteConnect includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack\u2122 Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: \u2022 Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services \u2022 Disable the logic debug service.</p>\n<p><strong>Mitigation</strong><br>Follow the information according to SCADAPack\u2122 Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit \u2022 Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services. \u2022 Disable the logic debug service.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/754.html\">CWE-754 Improper Check for Unusual or Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-041-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-041-01 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 17 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 17 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-03",
        "title": "Schneider Electric EcoStruxure Data Center Expert",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-076-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a hard-coded credentials vulnerability in its EcoStruxure IT Data Center Expert (DCE) product that requires administrator credentials and enabling a feature (SOCKS Proxy) that is off by default. The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure, and remote compromise of the offer which could result in disruption of operations and access to system data.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Data Center Expert are affected:</p>\n<ul>\n<li>EcoStruxure IT Data Center Expert vers:intdot/&lt;=9.0</li>\n<li>EcoStruxure IT Data Center Expert 9.1</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.2</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Data Center Expert</td>\n<td>Use of Hard-coded Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13957</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A hard-coded credentials vulnerability exists that could lead to information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.</p>\n<p><a href=\"https://nvd.nist.gov/vuln/detail/CVE-2025-13957\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Data Center Expert</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) v9.0 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>v9.1 of EcoStruxure IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data-center-expert/#software-and-firmware</p>\n<p><strong>Mitigation</strong><br>If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Harden the DCE instance according to the cybersecurity best practices documented in the EcoStruxure IT Data Center Expert Security Handbook \u2022 Ensure the SOCKS Proxy is disabled as in the default configuration.</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert PDF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-05.pdf</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert CSAF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-05.json</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>hassan ali of TrendAI Zero Day Initiative reported this vulnerability to Schneider Electric</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices: * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-05 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric SEVD-2026-069-05 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 17 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 17 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<div class=\"OutlineElement Ltr SCXW244767289 BCX8\">\n<p>CISA has added one new vulnerability to its <a class=\"Hyperlink SCXW244767289 BCX8\" href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" rel=\"noreferrer noopener\"><u>Known Exploited Vulnerabilities (KEV) Catalog</u></a>, based on evidence of active exploitation.&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW244767289 BCX8\">\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-47813\" target=\"_blank\"><u>CVE-2025-47813</u></a> Wing FTP Server Information Disclosure Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\"><u>Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</u></a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\"><u>BOD 22-01 Fact Sheet</u></a> for more information.</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW244767289 BCX8\">\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Mon, 16 Mar 26 12:00:00 +0000",
        "last_updated": "Mon, 16 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/13/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/13/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3909\" target=\"_blank\">CVE-2026-3909</a> Google Skia Out-of-Bounds Write Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3910\" target=\"_blank\">CVE-2026-3910</a> Google Chromium V8 Unspecified Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 13 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 13 Mar 26 12:00:00 +0000"
    }
]