[
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/06/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/06/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35616\" target=\"_blank\">CVE-2026-35616</a> - Fortinet FortiClient EMS Improper Access Control Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 06 Apr 26 12:00:00 +0000",
        "last_updated": "Mon, 06 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-01",
        "title": "Siemens SICAM 8 Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-092-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - RTUM85 for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE - RTUM85 Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens SICAM 8 Products are affected:</p>\n<ul>\n<li>CPCI85 Central Processing/Communication vers:intdot/&lt;26.10 (CVE-2026-27663, CVE-2026-27664)</li>\n<li>RTUM85&nbsp;RTU Base vers:intdot/&lt;26.10 (CVE-2026-27663)</li>\n<li>SICORE Base system vers:intdot/&lt;26.10.0 (CVE-2026-27664)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Siemens</td>\n<td>Siemens SICAM 8 Products</td>\n<td>Allocation of Resources Without Limits or Throttling, Out-of-bounds Write</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM 8 Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CPCI85 Central Processing/Communication, RTUM85&nbsp;RTU Base</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware RTUM85 V26.10 is present within \u201cCP-8010/CP-8012 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within \u201cSICAM S8000 Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109818240</p>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware CPCI85 V26.10 is present within \u201cCP-8031/CP-8050 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within \u201cSICAM EGS Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109972536/</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27664</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27664\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM 8 Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CPCI85 Central Processing/Communication, SICORE Base system</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware CPCI85 V26.10 is present within \u201cCP-8031/CP-8050 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within \u201cSICAM EGS Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109972536/</p>\n<p><strong>Vendor fix</strong><br>Update to V26.10.0 or later version The firmware SICORE V26.10.0 is present within \u201cCP-8010/CP-8012 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within \u201cSICAM S8000 Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109818240</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>T. Weber, S. Dietz, D. Blagojevic, and F. Koroknai of CyberDanube coordinated disclosure of CVE-2026-27663</li>\n<li>S. Dietz of CyberDanube and VERBUND Digital Power coordinated disclosure of CVE-2026-27664</li>\n<li>S. Dietz of Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-246443 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-02</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-246443 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-02",
        "title": "Yokogawa CENTUM VP",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-092-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to login as the PROG user and modify permissions.</strong></p>\n<p>The following versions of Yokogawa CENTUM VP are affected:</p>\n<ul>\n<li>CENTUM VP &gt;=R5.01.00|</li>\n<li>CENTUM VP &gt;=R6.01.00|</li>\n<li>CENTUM VP vR7.01.00 (CVE-2025-7741)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 4</td>\n<td>Yokogawa</td>\n<td>Yokogawa CENTUM VP</td>\n<td>Use of Hard-coded Password</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Food and Agriculture</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7741</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected products contain a hardcoded password for the user account (PROG) used for CENTUM Authentication Mode within the system. Under the following conditions, there is a risk that an attacker could log in as the PROG user. The default permission for the PROG users is S1 permission (equivalent to OFFUSER). Therefore, for properly permission-controlled targets of operation and monitoring, even if an attacker logs in as the PROG user, the risk of critical operations or configuration changes being performed is considered low. If the PROG user's permissions have been changed for any reason, there is a risk that operations or configuration changes may be performed under the modified permissions. Additionally, exploiting this vulnerability requires an attacker to already have access to the HIS screen controls.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7741\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Yokogawa CENTUM VP</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Yokogawa</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Yokogawa CENTUM VP: &gt;=R5.01.00|&lt;R5.04.20, Yokogawa CENTUM VP: &gt;=R6.01.00|&lt;R6.12.00, Yokogawa CENTUM VP: vR7.01.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Yokogawa recommends users applying the following mitigations to affected versions:</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R5.01.00 to R5.04.20: Change the user authentication mode to Windows Authentication Mode.</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R6.01.00 to R6.12.00: Change the user authentication mode to Windows Authentication Mode.</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R7.01.00: Apply patch software R7.01.10.</p>\n<p><strong>Mitigation</strong><br>NOTE:Changing to Windows Authentication Mode requires engineering work. If users wish to make this change, please contact Yokogawa directly https://contact.yokogawa.com/cs/gw?c-id=000498.<br><a href=\"https://contact.yokogawa.com/cs/gw?c-id=000498\">https://contact.yokogawa.com/cs/gw?c-id=000498</a></p>\n<p><strong>Mitigation</strong><br>For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0003 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf<br><a href=\"https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf\">https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/259.html\">CWE-259 Use of Hard-coded Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Yokogawa reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-02</td>\n<td>1</td>\n<td>Initial Republication of YSAR-26-0003</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/02/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/02/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added&nbsp;one&nbsp;new&nbsp;vulnerability&nbsp;to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3502\" target=\"_blank\">CVE-2026-3502</a>&nbsp;TrueConf&nbsp;Client Download of Code Without Integrity Check Vulnerability&nbsp;</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV&nbsp;Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a>&nbsp;for more information.&nbsp;</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing&nbsp;timely&nbsp;remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>&nbsp;as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-03",
        "title": "Hitachi Energy Ellipse",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-092-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Hitachi Energy is aware of a Jasper Report vulnerability that affects the Ellipse product versions mentioned in this document below. This vulnerability can be exploited to carry out remote code execution (RCE) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.</strong></p>\n<p>The following versions of Hitachi Energy Ellipse are affected:</p>\n<ul>\n<li>Ellipse vers:Ellipse/&lt;=9.0.50 (CVE-2025-10492)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Hitachi Energy</td>\n<td>Hitachi Energy Ellipse</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-10492</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in Jasper Report third party component that is used for creating custom reports in Ellipse product. A Java deserialization vulnerability has been discovered in Jaspersoft Library. Improper handling of externally supplied data may allow attackers to execute arbitrary code remotely on systems that use the affected library.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-10492\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy Ellipse</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ellipse versions 9.0.50 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Since the vulnerability exists in Jasper Report component that is external to Ellipse application, restrict the loading of external custom reports created by end users by allowing only trusted Jasper reports generated by the system administrator.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hitachi Energy PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Support</h2>\n<p>For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.</p>\n<hr>\n<h2>General Mitigation Factors</h2>\n<p>Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000238 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-24</td>\n<td>1</td>\n<td>Initial public release</td>\n</tr>\n<tr>\n<td>2026-04-02</td>\n<td>2</td>\n<td>Initial CISA Republication of Hitachi Energy PSIRT 8DBD000238 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\"> Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-5281\" target=\"_blank\">CVE-2026-5281</a> Google Dawn Use-After-Free Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 01 Apr 26 12:00:00 +0000",
        "last_updated": "Wed, 01 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-090-01",
        "title": "Anritsu Remote Spectrum Monitor",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-090-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-090-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow attackers with network access to alter operational settings, obtain sensitive signal data, or disrupt device availability.</strong></p>\n<p>The following versions of Anritsu Remote Spectrum Monitor are affected:</p>\n<ul>\n<li>Remote Spectrum Monitor MS27100A vers:all/* (CVE-2026-3356)</li>\n<li>Remote Spectrum Monitor MS27101A vers:all/* (CVE-2026-3356)</li>\n<li>Remote Spectrum Monitor MS27102A vers:all/* (CVE-2026-3356)</li>\n<li>Remote Spectrum Monitor MS27103A vers:all/* (CVE-2026-3356)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Anritsu</td>\n<td>Anritsu Remote Spectrum Monitor</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications, Defense Industrial Base, Emergency Services, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-3356</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The MS27102A Remote Spectrum Monitor is vulnerable to an authentication bypass that allows unauthorized users to access and manipulate its management interface. Because the device provides no mechanism to enable or configure authentication, the issue is inherent to its design rather than a deployment error.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3356\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anritsu Remote Spectrum Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anritsu</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anritsu Remote Spectrum Monitor MS27100A: vers:all/*, Anritsu Remote Spectrum Monitor MS27101A: vers:all/*, Anritsu Remote Spectrum Monitor MS27102A: vers:all/*, Anritsu Remote Spectrum Monitor MS27103A: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anritsu has no plans to fix this issue. Anritsu recommends that users deploy Remote Spectrum Monitor within secure network environments to mitigate potential risks.</p>\n<p><strong>Mitigation</strong><br>Users can contact Anritsu Technical Support (1-800-267-4878) for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Souvik Kandar reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-31</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-31</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 31 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 31 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-090-02",
        "title": "PX4 Autopilot",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-090-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-090-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker with access to the MAVLink interface to execute arbitrary shell commands without cryptographic authentication.</strong></p>\n<p>The following versions of PX4 Autopilot are affected:</p>\n<ul>\n<li>Autopilot v1.16.0_SITL_latest_stable (CVE-2026-1579)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>PX4</td>\n<td>PX4 Autopilot</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems, Emergency Services, Defense Industrial Base</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1579</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The MAVLink communication protocol does not require cryptographic authentication by default. When MAVLink 2.0 message signing is not enabled, any message -- including SERIAL_CONTROL, which provides interactive shell access -- can be sent by an unauthenticated party with access to the MAVLink interface. PX4 provides MAVLink 2.0 message signing as the cryptographic authentication mechanism for all MAVLink communication. When signing is enabled, unsigned messages are rejected at the protocol level.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1579\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>PX4 Autopilot</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>PX4</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PX4 Autopilot: v1.16.0_SITL_latest_stable</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>PX4 recommends enabling MAVLink 2.0 message signing as the authentication mechanism for all non\u2011USB communication links. PX4 has published a security hardening guide for integrators and manufacturers at https://docs.px4.io/main/en/mavlink/security_hardening.<br><a href=\"https://docs.px4.io/main/en/mavlink/security_hardening\">https://docs.px4.io/main/en/mavlink/security_hardening</a></p>\n<p><strong>Mitigation</strong><br>Message signing configuration documentation can be found at https://docs.px4.io/main/en/mavlink/message_signing.<br><a href=\"https://docs.px4.io/main/en/mavlink/message_signing\">https://docs.px4.io/main/en/mavlink/message_signing</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Dolev Aviv of Cyviation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-31</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-31</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 31 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 31 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/30/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/30/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3055\" target=\"_blank\">CVE-2026-3055</a> Citrix NetScaler Out-of-Bounds Read Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 30 Mar 26 12:00:00 +0000",
        "last_updated": "Mon, 30 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/27/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-53521\" target=\"_blank\">CVE-2025-53521</a> F5 BIG-IP Remote Code Execution Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 27 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 27 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-02",
        "title": "OpenCode Systems OC Messaging and USSD Gateway",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter.</strong></p>\n<p>The following versions of OpenCode Systems OC Messaging and USSD Gateway are affected:</p>\n<ul>\n<li>OC Messaging 6.32.2 (CVE-2025-70614)</li>\n<li>USSD Gateway 6.32.2 (CVE-2025-70614)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.1</td>\n<td>OpenCode Systems</td>\n<td>OpenCode Systems OC Messaging and USSD Gateway</td>\n<td>Improper Access Control</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Bulgaria</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-70614</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>OpenCode Systems Custom Messaging Gateway 6.32.2 contains a web access vulnerability allowing one authenticated user to gain access to another authenticated user's messages via a crafted identifier parameter.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-70614\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OpenCode Systems OC Messaging and USSD Gateway</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OpenCode Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OpenCode Systems OC Messaging: 6.32.2, OpenCode Systems USSD Gateway: 6.32.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The vulnerability was identified by OpenCode Systems on January 5, 2026 and remediated on January 6, 2026 with the release of version 6.33.11.</p>\n<p><strong>Mitigation</strong><br>For more information, contact OpenCode: https://opencode.com/about/contact-us<br><a href=\"https://opencode.com/about/contact-us\">https://opencode.com/about/contact-us</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/284.html\">CWE-284 Improper Access Control</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hussein Amer reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-01",
        "title": "WAGO GmbH & Co. KG Industrial Managed Switches",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.</strong></p>\n<p>The following versions of WAGO GmbH &amp; Co. KG Industrial Managed Switches are affected:</p>\n<ul>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587)</li>\n<li>WAGO Firmware version V1.2.1.S1 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>WAGO</td>\n<td>WAGO GmbH &amp; Co. KG Industrial Managed Switches</td>\n<td>Hidden Functionality</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-3587</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3587\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>WAGO GmbH &amp; Co. KG Industrial Managed Switches</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>WAGO</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware versions prior to V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware versions prior to V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware versions prior to V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware versions prior to V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware version V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware version V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware version V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-001, WAGO WAGO Firmware version V1.2.1.S1: WAGO_Hardware_852-1813/010-001</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>WAGO has identified the following specific workarounds and mitigations users can apply to reduce risk: Product Group: WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1813/010-001, WAGO Firmware installed on WAGO Hardware 852-1813/010-001): Please update your devices to the specified fixed Firmware version.</p>\n<p><strong>Mitigation</strong><br>Lean Managed Switch 852-1812, Lean Managed Switch 852-1813, Lean Managed Switch 852-1813/000-001, Lean Managed Switch 852-1816, Lean Managed Switch 852-1812/010-000, Lean Managed Switch 852-1813/010-000, Lean Managed Switch 852-1816/010-000, Lean Managed Switch 852-1813/010-001: To eliminate the attack vector deactivate ssh and telnet on the device.</p>\n<p><strong>Mitigation</strong><br>Industrial Managed Switch 852-303, Industrial Managed Switch 852-1305, Industrial Managed Switch 852-1305/000-001, Industrial Managed Switch 852-1505/000-001, Industrial Managed Switch 852-1505, Industrial Managed Switch 852-602, Industrial Managed Switch 852-603, Industrial Managed Switch 852-1605: To reduce the attack vector deactivate ssh and telnet on the devices. This ensures that the CLI is only accessible locally via RS232.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed: Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.3.S1 installed on Lean Managed Switch 852-1813/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.8.S1 installed on Industrial Managed Switch 852-303 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1505/000-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.1.9.S1 installed on Industrial Managed Switch 852-1505 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-602 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-603 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.5.S1 installed on Industrial Managed Switch 852-1605 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816/010-000 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-001 are fixed versions for CVE-2026-3587</p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://www.wago.com/de-en/automation-technology/psirt\">https://www.wago.com/de-en/automation-technology/psirt</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://certvde.com/en/advisories/VDE-2026-020\">https://certvde.com/en/advisories/VDE-2026-020</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated WAGO GmbH &amp; Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json.<br><a href=\"https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json\">https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/912.html\">CWE-912 Hidden Functionality</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CERT@VDE coordination reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Republication of WAGO GmbH &amp; Co. KG VDE-2026-020</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-03",
        "title": "PTC Windchill Product Lifecycle Management",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-085-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-085-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution.</strong></p>\n<p>The following versions of PTC Windchill Product Lifecycle Management are affected:</p>\n<ul>\n<li>Windchill PDMLink 11.0_M030 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 11.1_M020 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 11.2.1.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 12.0.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 12.1.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.0.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.0.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.1.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.2.0 (CVE-2026-4681)</li>\n<li>Windchill PDMLink 13.1.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 11.0_M030 (CVE-2026-4681)</li>\n<li>FlexPLM 11.1_M020 (CVE-2026-4681)</li>\n<li>FlexPLM 11.2.1.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.0.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.0.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.1.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 12.1.3.0 (CVE-2026-4681)</li>\n<li>FlexPLM 13.0.2.0 (CVE-2026-4681)</li>\n<li>FlexPLM 13.0.3.0 (CVE-2026-4681)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>PTC</td>\n<td>PTC Windchill Product Lifecycle Management</td>\n<td>Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-4681</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-4681\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>PTC Windchill Product Lifecycle Management</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>PTC</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PTC Windchill PDMLink: 11.0_M030, PTC Windchill PDMLink: 11.1_M020, PTC Windchill PDMLink: 11.2.1.0, PTC Windchill PDMLink: 12.0.2.0, PTC Windchill PDMLink: 12.1.2.0, PTC Windchill PDMLink: 13.0.2.0, PTC Windchill PDMLink: 13.1.0.0, PTC Windchill PDMLink: 13.1.1.0, PTC Windchill PDMLink: 13.1.2.0, PTC Windchill PDMLink: 13.1.3.0, PTC FlexPLM: 11.0_M030, PTC FlexPLM: 11.1_M020, PTC FlexPLM: 11.2.1.0, PTC FlexPLM: 12.0.0.0, PTC FlexPLM: 12.0.2.0, PTC FlexPLM: 12.0.3.0, PTC FlexPLM: 12.1.2.0, PTC FlexPLM: 12.1.3.0, PTC FlexPLM: 13.0.2.0, PTC FlexPLM: 13.0.3.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>PTC is aware of the issue and is actively developing a fix. In the meantime, PTC recommends applying the recommended workaround. Until official patches are available, customers must take urgent steps to safeguard their environments. Specifically: Protect any publicly accessible Windchill systems</p>\n<p><strong>Vendor fix</strong><br>While publicly accessible Windchill and FlexPLM systems are at higher risk and require immediate attention, PTC strongly recommends applying the mitigation steps to all deployments, regardless of Internet exposure</p>\n<p><strong>Vendor fix</strong><br>Apply the same precautions to FlexPLM deployments</p>\n<p><strong>Vendor fix</strong><br>The following Apache and IIS HTTP Server configuration update should be IMMEDIATELY applied to every Windchill or FlexPLM system: Customers using Apache HTTP Server should only follow \"Apache HTTP Server Configuration \u2013 Workaround Steps\" section steps</p>\n<p><strong>Mitigation</strong><br>Customers using Microsoft IIS should only follow \"IIS Configuration - Workaround Steps\" section steps</p>\n<p><strong>Mitigation</strong><br>Please explicitly note that the same mitigation steps must also be applied on File Server / Replica Server configurations where applicable</p>\n<p><strong>Mitigation</strong><br>For Windchill releases prior to 11.0 M030, workarounds may need to be altered to apply to unsupported previous releases</p>\n<p><strong>Mitigation</strong><br>For Apache HTTP Server and IIS configuration workaround steps, please refer to the official advisory at:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability.<br><a href=\"https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability\">https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability</a></p>\n<p><strong>Mitigation</strong><br>If immediate remediation is not feasible, additional guidance and remediation options are available:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability.<br><a href=\"https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability\">https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous source reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Initial Republication of PTC's CS466318</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33634\" target=\"_blank\">CVE-2026-33634</a> Aqua Security Trivy Embedded Malicious Code Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 26 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 26 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/25/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/25/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33017\" target=\"_blank\">CVE-2026-33017</a> Langflow Code Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 25 Mar 26 12:00:00 +0000",
        "last_updated": "Wed, 25 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-083-01",
        "title": "Grassroots DICOM (GDCM)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-083-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-083-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to send a specially crafted file, and when parsed, could result in a denial-of-service condition.</strong></p>\n<p>The following versions of Grassroots DICOM (GDCM) are affected:</p>\n<ul>\n<li>Grassroots DICOM (GDCM) 3.2.2 (CVE-2026-3650)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Grassroots</td>\n<td>Grassroots DICOM (GDCM)</td>\n<td>Missing Release of Memory after Effective Lifetime</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-3650</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A memory leak exists in the Grassroots DICOM library (GDCM). The bug occurs when parsing malformed DICOM files with non-standard VR types in file meta information. The vulnerability leads to vast memory allocations and resource depletion, triggering a denial-of-service condition. A maliciously crafted file can fill the heap in a single read operation without properly releasing it.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3650\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Grassroots DICOM (GDCM)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Grassroots</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Grassroots Grassroots DICOM (GDCM): 3.2.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer of Grassroots DICOM (GDCM) has not responded to requests to work with CISA to mitigate this vulnerability. For update information refer to the software page on SourceForge.</p>\n<p><strong>Mitigation</strong><br>https://sourceforge.net/projects/gdcm/.<br><a href=\"https://sourceforge.net/projects/gdcm/\">https://sourceforge.net/projects/gdcm/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Volodymyr Bihunenko, Mykyta Mudryi, and Markiian Chaklosh of ARIMLABS reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Publication.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-01",
        "title": "Pharos Controls Mosaic Show Controller",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges.</strong></p>\n<p>The following versions of Pharos Controls Mosaic Show Controller are affected:</p>\n<ul>\n<li>Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Pharos Controls</td>\n<td>Pharos Controls Mosaic Show Controller</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United Kingdom</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-2417</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-2417\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Pharos Controls Mosaic Show Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Pharos Controls</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Pharos Controls Mosaic Show Controller Firmware: 2.15.3</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>James Tully reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-02",
        "title": "Schneider Electric EcoStruxure Foxboro DCS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure Foxboro DCS Control Software on Foxboro DCS workstations and servers. Control Core Services and all runtime software, like FCPs, FDCs, and FBMs, are not affected. The EcoStruxure Foxboro DCS ([https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/)) product is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediation provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected:</p>\n<ul>\n<li>EcoStruxure Foxboro DCS vers:generic/</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Foxboro DCS</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1286</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1286\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Foxboro DCS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Foxboro DCS versions prior to CS8.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version CS 8.1 of EcoStruxure Foxboro DCS includes a fix for this vulnerability and is available through [https://buyautomation.se.com/](https://buyautomation.se.com/) CS 8.1 requires FX-V3 licenses, standard upgrade procedures apply. A reboot is required for workstations and servers. Depending on the existing system version, online upgrade without production interruption might be possible. Schneider Electric recommends you work with your local field service representative or technical service consultant for further information.&nbsp;<br><a href=\"https://buyautomation.se.com/\">https://buyautomation.se.com/</a></p>\n<p><strong>Mitigation</strong><br>If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The vulnerability is attacked with manipulated data from external sources to the DCS computers. Examples for these are: * Configuration taglists * DirectAccess Scripts * Any partial or full Galaxy backups * Library files * Code snippets * ASCII files of any sort * Generally, any file getting from outside the DCS computer on a DCS computer. Only use data from trusted sources, check for correct file name endings on data files, check for reasonable file sizes for any files coming to the system, and check structured data for any fields or columns which might be unexpected. Check for unusual manipulations of data within data files and reject files containing unexpected data or structures. Use secure communication channels and encrypt communications when communicating outside the site network. Avoid and ban removable media (e.g. USB sticks or drives) Minimize count of users with engineering or administrative rights to DCS computers and ensure all interactions on DCS computers are executed with minimal user access rights. Consequently, isolating Foxboro DCS computers will help minimizing the risk of this vulnerability being exploited.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-13</td>\n<td>2</td>\n<td>Updated remediation and mitigations section.</td>\n</tr>\n<tr>\n<td>2026-03-24</td>\n<td>3</td>\n<td>Initial CISA Republication of Schneider Electric Security Notification SEVD-2026-069-03</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-03",
        "title": "Schneider Electric Plant iT/Brewmaxx",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-083-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-083-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution.</strong></p>\n<p>The following versions of Schneider Electric Plant iT/Brewmaxx are affected:</p>\n<ul>\n<li>Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.9</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Plant iT/Brewmaxx</td>\n<td>Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Critical Manufacturing, Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-49844</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-49844\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46817</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46817\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46818</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46818\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-46819</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-46819\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Plant iT/Brewmaxx</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Plant iT/Brewmaxx: 9.60_and_above</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:</p>\n<p><strong>Mitigation</strong><br>Install Patch ProLeiT-2025-001 via ProLeiT Support<br><a href=\"https://www.proleit.com/support/\">https://www.proleit.com/support/</a></p>\n<p><strong>Mitigation</strong><br>After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality</p>\n<p><strong>Mitigation</strong><br>Force usage of secure Redis configuration templates in system settings as documented in the patch manual</p>\n<p><strong>Mitigation</strong><br>Restart all patched servers and workstations</p>\n<p><strong>Mitigation</strong><br>Schneider Electric strongly recommends the following industry cybersecurity best practices.</p>\n<p><strong>Mitigation</strong><br>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.</p>\n<p><strong>Mitigation</strong><br>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.</p>\n<p><strong>Mitigation</strong><br>Place all controllers in locked cabinets and never leave them in the \"Program\" mode.</p>\n<p><strong>Mitigation</strong><br>Never connect programming software to any network other than the network intended for that device.</p>\n<p><strong>Mitigation</strong><br>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.</p>\n<p><strong>Mitigation</strong><br>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.</p>\n<p><strong>Mitigation</strong><br>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.</p>\n<p><strong>Mitigation</strong><br>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.</p>\n<p><strong>Mitigation</strong><br>For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.<br><a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">https://www.se.com/us/en/download/document/7EN52-0390/</a></p>\n<p><strong>Vendor fix</strong><br>For more information, see Schneider Electric security notification \"SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx\"<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-013-01.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-24</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-24</td>\n<td>1</td>\n<td>Initial Republication of SEVD-2026-013-01</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 24 Mar 26 12:00:00 +0000",
        "last_updated": "Tue, 24 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/20/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Five Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/20/cisa-adds-five-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added five new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-31277\" target=\"_blank\">CVE-2025-31277</a> Apple Multiple Products Buffer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-32432\" target=\"_blank\">CVE-2025-32432</a> Craft CMS Code Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-43510\" target=\"_blank\">CVE-2025-43510</a> Apple Multiple Products Improper Locking Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-43520\" target=\"_blank\">CVE-2025-43520</a> Apple Multiple Products Classic Buffer Overflow Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-54068\" target=\"_blank\">CVE-2025-54068</a> Laravel Livewire Code Injection Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 20 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 20 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-target-commercial-messaging-application-accounts",
        "title": "Russian Intelligence Services Target Commercial Messaging Application Accounts",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-target-commercial-messaging-application-accounts",
        "summary": "<p>CISA and the Federal Bureau of Investigation released a <a href=\"https://www.ic3.gov/PSA/2026/PSA260320\" target=\"_blank\">Public Service Announcement (PSA)</a> warning about ongoing phishing campaigns by cyber actors associated with the Russian Intelligence Services targeting commercial messaging applications (CMAs). These campaigns aim to bypass encryption to compromise to individual user accounts with targets including current and former U.S. government officials, military personnel, political figures, and journalists.&nbsp;&nbsp;</p>\n<p>Evidence shows that cyber actors have been able to compromise individual CMA accounts, but not encryption of the applications themselves. The actors\u2019 global campaigns have resulted in unauthorized access to thousands of individual CMA accounts to view the victims\u2019 messages and contact lists, send messages, and conduct additional phishing against other CMA accounts. &nbsp;</p>\n<p>CISA and FBI urge CMA users to review the PSA, follow recommended cybersecurity practices, and remain vigilant for suspicious activity.</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 20 Mar 26 12:00:00 +0000",
        "last_updated": "Fri, 20 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-03",
        "title": "Schneider Electric EcoStruxure Automation Expert",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure\u2122 Automation Expert product. The EcoStruxure\u2122 Automation Expert product is plant automation software designed for digital control systems in discrete, hybrid and continuous industrial processes. A totally integrated automation solution designed to enhance your flexibility, efficiency and scalability. Failure to apply the remediation provided below may risk execution of arbitrary commands on the engineering workstation, which could result in a potential compromise of full system.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Automation Expert are affected:</p>\n<ul>\n<li>EcoStruxure\u2122 Automation Expert vers:intdot/&lt;25.0.1, 25.0.1</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.2</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Automation Expert</td>\n<td>Improper Control of Generation of Code ('Code Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-2273</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-2273\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Automation Expert</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure\u2122 Automation Expert Versions prior to v25.0.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version v25.0.1 of EcoStruxure\u2122 Automation Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/<br><a href=\"https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/\">https://www.se.com/ww/en/product-range/23643079-ecostruxure-automation-expert/</a></p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Solution and archive files must be stored within the user\u2019s home directory or in any location protected by appropriate Windows file\u2011system access controls to prevent unauthorized access in multi\u2011user environments. Users who choose to store files outside their home directory are responsible for applying restrictive Windows permissions to secure those locations. Before opening any solution or archive file, users are required to verify its authenticity and ensure that it has not been modified by unauthorized users. For detailed mitigation steps, refer to the User Manual - https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help<br><a href=\"https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help\">https://product-help.se.com/EcoStruxure%20Automation%20Expert/25.0/Offer%20Guides/en-US/EAE_UM?t=EAE_UM%2FSolutionIntegrity-FE037ED3.html%3Frhhlterm%3Dundefined%253Frhsearch%253Dundefined&amp;theme=Help</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/94.html\">CWE-94 Improper Control of Generation of Code ('Code Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n<li>Raffaele Bova of Nozomi Networks reported this vulnerability to Schneider Electric.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-04 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-19</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-069-04 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "title": "Mitsubishi Electric CNC Series",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products.</strong></p>\n<p>The following versions of Mitsubishi Electric CNC Series are affected:</p>\n<ul>\n<li>M800VW (BND-2051W000) &lt;=BB</li>\n<li>M800VS (BND-2052W000) &lt;=BB</li>\n<li>M80V (BND-2053W000) &lt;=BB</li>\n<li>M80VW (BND-2054W000) &lt;=BB</li>\n<li>M800W (BND-2005W000) &lt;=FM</li>\n<li>M800S (BND-2006W000) &lt;=FM</li>\n<li>M80 (BND-2007W000) &lt;=FM</li>\n<li>M80W (BND-2008W000) &lt;=FM</li>\n<li>E80 (BND-2009W000) &lt;=FM</li>\n<li>C80 (BND-2036W000) vers:all/*</li>\n<li>M750VW (BND-1015W002) vers:all/*</li>\n<li>M730VW (BND-1015W000) vers:all/*</li>\n<li>M720VW (BND-1015W000) vers:all/*</li>\n<li>M750VS (BND-1012W002) vers:all/*</li>\n<li>M730VS (BND-1012W000-**) vers:all/*</li>\n<li>M720VS (BND-1012W000) vers:all/*</li>\n<li>M70V (BND-1018W000) vers:all/*</li>\n<li>E70 (BND-1022W000) vers:all/*</li>\n<li>NC Trainer2 (BND-1802W000) vers:all/*</li>\n<li>NC Trainer2 plus (BND-1803W000) vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.9</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric CNC Series</td>\n<td>Improper Validation of Specified Index, Position, or Offset in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-2399</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2399\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric CNC Series</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric M800VW (BND-2051W000): &lt;=BB, Mitsubishi Electric M800VS (BND-2052W000): &lt;=BB, Mitsubishi Electric M80V (BND-2053W000): &lt;=BB, Mitsubishi Electric M80VW (BND-2054W000): &lt;=BB, Mitsubishi Electric M800W (BND-2005W000): &lt;=FM, Mitsubishi Electric M800S (BND-2006W000): &lt;=FM, Mitsubishi Electric M80 (BND-2007W000): &lt;=FM, Mitsubishi Electric M80W (BND-2008W000): &lt;=FM, Mitsubishi Electric E80 (BND-2009W000): &lt;=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): vers:all/*, Mitsubishi Electric M730VW (BND-1015W000): vers:all/*, Mitsubishi Electric M720VW (BND-1015W000): vers:all/*, Mitsubishi Electric M750VS (BND-1012W002): vers:all/*, Mitsubishi Electric M730VS (BND-1012W000): vers:all/*, Mitsubishi Electric M720VS (BND-1012W000): vers:all/*, Mitsubishi Electric M70V (BND-1018W000): vers:all/*, Mitsubishi Electric E70 (BND-1022W000): vers:all/*, Mitsubishi Electric NC Trainer2 (BND-1802W000): vers:all/*, Mitsubishi Electric NC Trainer2 plus (BND-1803W000): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW(BND-2051W000), M800VS(BND-2052W000), M80V(BND-2053W000), and M80VW(BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (FN or later) for Mitsubishi Electric M800W(BND-2005W000), M800S(BND-2006W000), M80(BND-2007W000), M80W(BND-2008W000), and E80(BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product: M800V/M80V Series Instruction Manual \"16. Appendix 3 IP Address Filter Setting Function\", M800/M80/E80 Series Instruction Manual \"15. Appendix 2 IP Address Filter Setting Function\"</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information, see Mitsubishi Electric 2025-022. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf&nbsp;<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1285.html\">CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of CISA V20250121-001#02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial CISA Republication of&nbsp;Mitsubishi Electric security advisory 2025-022</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-07",
        "title": "IGL-Technologies eParking.fi",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.</strong></p>\n<p>The following versions of IGL-Technologies eParking.fi are affected:</p>\n<ul>\n<li>eParking.fi vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>IGL-Technologies</td>\n<td>IGL-Technologies eParking.fi</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Finland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-29796</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-29796\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.<br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31903</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31903\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31926</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Charging station authentication identifiers are publicly accessible via web-based mapping platforms.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31926\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IGL-Technologies eParking.fi</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IGL-Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IGL-Technologies eParking.fi: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls:<br>1) Enforce modern security profiles and stronger authentication.<br>2) Device\u2011level whitelisting was implemented to ensure that only authorized charging units can connect.<br>3) Rate\u2011limiting controls prevent excessive requests and reduces DoS risk.<br>4) Enhanced automated monitoring and alerting to detection abnormal network activity.</p>\n<p><strong>Mitigation</strong><br>Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO\u202f27001:2022 security program and tighten security requirements for future third\u2011party OCPP hardware approvals.</p>\n<p><strong>Mitigation</strong><br>For more information please contact the IGL-Technologies security team at this email address: security@igl.fi.<br><a href=\"mailto:security@igl.fi\">mailto:security@igl.fi</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-06",
        "title": "CTEK Chargeportal",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.</strong></p>\n<p>The following versions of CTEK Chargeportal are affected:</p>\n<ul>\n<li>Chargeportal vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>CTEK</td>\n<td>CTEK Chargeportal</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Sweden</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25192</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25192\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31904</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31904\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27649</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27649\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-28204</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Charging station authentication identifiers are publicly accessible via web-based mapping platforms.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-28204\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CTEK Chargeportal</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CTEK</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CTEK Chargeportal: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support.<br><a href=\"https://www.ctek.com/support\">https://www.ctek.com/support</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine, Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-01",
        "title": "Schneider Electric Modicon M241, M251, and M262",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product.</strong></p>\n<p>The following versions of Schneider Electric Modicon M241, M251, and M262 are affected:</p>\n<ul>\n<li>Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241</li>\n<li>Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251</li>\n<li>Modicon M262 versions prior to 5.4.10.12 Modicon_Controller_M262</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Modicon M241, M251, and M262</td>\n<td>Improper Resource Shutdown or Release</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13901</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13901\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Modicon M241, M251, and M262</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon M262 versions prior to 5.4.10.12: Modicon_Controller_M262</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure\u2122 Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure\u2122 Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-01 Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf. Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-01.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-01.pdf</a></p>\n<p><strong>Mitigation</strong><br>All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Filter ports and IP through the embedded firewall. Use encrypted communication links. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/404.html\">CWE-404 Improper Resource Shutdown or Release</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric</li>\n<li>Schneider Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-069-01</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-04",
        "title": "Schneider Electric EcoStruxure PME and EPO",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure PME and EPO are affected:</p>\n<ul>\n<li>EcoStruxure Power Monitoring Expert (PME) 2022 &lt;=2022</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023_R2</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024_R2</li>\n<li>EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module &lt;=2022</li>\n<li>EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module 2024</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2023_R2_Hotfix_282807</li>\n<li>EcoStruxure Power Monitoring Expert (PME) 2024_R2_Hotfix_279338__2024R2</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure PME and EPO</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health, Information Technology, Critical Manufacturing, Commercial Facilities, Energy, Transportation Systems, Government Services and Facilities, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11739</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A deserialization of untrusted data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11739\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure PME and EPO</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure Power Monitoring Expert (PME) Version 2022 and prior, EcoStruxure Power Monitoring Expert (PME) Version 2023, EcoStruxure Power Monitoring Expert (PME) Version 2023 R2, EcoStruxure Power Monitoring Expert (PME) Version 2024, EcoStruxure Power Monitoring Expert (PME) Version 2024 R2, EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module Version 2022 and prior, EcoStruxure Power Operation (EPO) 2024 with Advanced Reporting and Dashboards Module Version 2024</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Hotfix_279338_Release_2024R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this hotfix. No reboot required.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2024 R3. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>Vendor fix</strong><br>Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this hotfix. No reboot required.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>Vendor fix</strong><br>Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for assistance.</p>\n<p><strong>No fix planned</strong><br>EcoStruxure Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. \u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments\u2022 Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.&nbsp;<br><a href=\"https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm\">https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm</a></p>\n<p><strong>No fix planned</strong><br>EcoStruxure Power Operation (EPO) 2022 version and EcoStruxure Power Monitoring Expert (PME) 2022 has reached its end of life and is no longer supported. \u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments\u2022 Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.&nbsp;<br><a href=\"https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm\">https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Note</h2>\n<p>EcoStruxure Power Operation 2022 with Advanced Reporting AND EcoStruxure Power Operation 2024 with Advanced Reporting utilizes EcoStruxure Power Monitoring Expert. You must update EcoStruxure Power Monitoring Expert separately from EcoStruxure Power Operation and apply the appropriate update for Power Monitoring Expert as described above.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-06 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-03-19</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric SEVD-2026-069-06 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/03/19/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/03/19/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20131\" target=\"_blank\">CVE-2026-20131</a> Cisco Secure Firewall Management Center (FMC) Software and Cisco Security Cloud Control (SCC) Firewall Management Deserialization of Untrusted Data Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-08",
        "title": "Automated Logic WebCTRL Premium Server",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to read, intercept, or modify communications.</strong></p>\n<p>The following versions of Automated Logic WebCTRL Premium Server are affected:</p>\n<ul>\n<li>WebCTRL Premium Server</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Automated Logic</td>\n<td>Automated Logic WebCTRL Premium Server</td>\n<td>Multiple Binds to the Same Port, Authentication Bypass by Spoofing, Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25086</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Under certain conditions, an attacker could bind to the same port used by WebCTRL. This could allow the attacker to craft and send malicious packets and impersonate the WebCTRL service without requiring code injection into the WebCTRL software.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25086\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/605.html\">CWE-605 Multiple Binds to the Same Port</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32666</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebCTRL systems that communicate over BACnet inherit the protocol's lack of network layer authentication. WebCTRL does not implement additional validation of BACnet traffic so an attacker with network access could spoof BACnet packets directed at either the WebCTRL server or associated AutomatedLogic controllers. Spoofed packets may be processed as legitimate.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32666\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/290.html\">CWE-290 Authentication Bypass by Spoofing</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-24060</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Service information is not encrypted when transmitted as BACnet packets over the wire, and can be sniffed, intercepted, and modified by an attacker. Valuable information such as the File Start Position and File Data can be sniffed from network traffic using Wireshark's BACnet dissector filter. The proprietary format used by WebCTRL to receive updates from the PLC can also be sniffed and reverse engineered.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24060\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Automated Logic WebCTRL Premium Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Automated Logic</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automated Logic WebCTRL Premium Server: &lt;v8.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since January 27, 2023. Users are advised to upgrade to the latest version of the WebCTRL server application, which supports the more secure BACnet/SC.</p>\n<p><strong>Mitigation</strong><br>For customers using supported versions of WebCTRL (WebCTRL 8.5 cumulative releases and later), Automated Logic provides secure configuration guidance for hardware and software deployments; BACnet Secure Connect (BACnet/SC) support, which introduces TLS encryption and mutual authentication; and published best practices for network segmentation, access control, and secure protocol implementation. Additional information is available at: https://www.automatedlogic.com/en/company/security-commitment/.<br><a href=\"https://www.automatedlogic.com/en/company/security-commitment/\">https://www.automatedlogic.com/en/company/security-commitment/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jonathan Lee, Thuy D. Nguyen and Neil C. Rowe of the Naval Postgraduate School reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-02",
        "title": "Schneider Electric Modicon Controllers M241, M251, M258, and LMC058",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser.</strong></p>\n<p>The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected:</p>\n<ul>\n<li>Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241</li>\n<li>Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251</li>\n<li>Modicon Controllers M258 all firmware versions Modicon_Controllers_M258</li>\n<li>Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.4</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Modicon Controllers M241, M251, M258, and LMC058</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13902</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13902\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Modicon Controllers M241, M251, M258, and LMC058</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000003059/\">https://www.se.com/ww/en/download/document/EIO0000003059/</a></p>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/EIO0000005500/\">https://www.se.com/ww/en/download/document/EIO0000005500/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/us/en/download/document/EIO0000003089/\">https://www.se.com/us/en/download/document/EIO0000003089/</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure\u2122 Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure\u2122 Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER.<br><a href=\"https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER\">https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER</a></p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n<p><strong>Mitigation</strong><br>Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The \"Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment\" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242.<br><a href=\"https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242\">https://download.schneider-electric.com/files?p_enDocType=User+guide&amp;p_File_Name=EIO0000004242.00.pdf&amp;p_Doc_Ref=EIO0000004242</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-069-02.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric</li>\n<li>Schneider Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-19</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-19</td>\n<td>1</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 19 Mar 26 12:00:00 +0000",
        "last_updated": "Thu, 19 Mar 26 12:00:00 +0000"
    }
]