· CISA Cybersecurity Advisory

PX4 Autopilot

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the MAVLink interface to execute arbitrary shell commands without cryptographic authentication. The following versions of PX4 Autopilot are affected: Autopilot v1.16.0_SITL_latest_stable (CVE-2026-1579) CVSS Vendor Equipment Vulnerabilities v3 9.8 PX4 PX4 Autopilot Missing Authentication for Critical Function…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the MAVLink interface to execute arbitrary shell commands without cryptographic authentication. The following versions of PX4 Autopilot are affected: Autopilot v1.16.0_SITL_latest_stable (CVE-2026-1579) CVSS Vendor Equipment Vulnerabilities v3 9.8 PX4 PX4 Autopilot Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Transportation Systems, Emergency Services, Defense Industrial Base Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-1579 The MAVLink communication protocol does not require cryptographic authentication by default. When MAVLink 2.0 message signing is not enabled, any message -- including SERIAL_CONTROL, which provides interactive shell access -- can be sent by an unauthenticated party with access to the MAVLink interface. PX4 provides MAVLink 2.0 message signing as the cryptographic authentication mechanism for all MAVLink communication. When signing is enabled, unsigned messages are rejected at the protocol level. View CVE Details Affected Products PX4 Autopilot Vendor: PX4 Product Version: PX4 Autopilot: v1.16.0_SITL_latest_stable Product Status: known_affected Remediations Mitigation PX4 recommends enabling MAVLink 2.0 message signing as the authentication mechanism for all non‑USB communication links. PX4 has published a security hardening guide for integrators and manufacturers at https://docs.px4.io/main/en/mavlink/security_hardening. https://docs.px4.io/main/en/mavlink/security_hardening Mitigation Message signing configuration documentation can be found at https://docs.px4.io/main/en/mavlink/message_signing. https://docs.px4.io/main/en/mavlink/message_signing Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Dolev Aviv of Cyviation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-31 Date Revision Summary 2026-03-31 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Anritsu Remote Spectrum Monitor

View CSAF Summary Successful exploitation of this vulnerability could allow attackers with network access to alter operational settings, obtain sensitive signal data, or disrupt device availability. The following versions of Anritsu Remote Spectrum Monitor are affected: Remote Spectrum Monitor MS27100A vers:all/* (CVE-2026-3356) Remote Spectrum Monitor MS27101A vers:all/* (CVE-2026-3356) Remote Spectrum Monitor…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow attackers with network access to alter operational settings, obtain sensitive signal data, or disrupt device availability. The following versions of Anritsu Remote Spectrum Monitor are affected: Remote Spectrum Monitor MS27100A vers:all/* (CVE-2026-3356) Remote Spectrum Monitor MS27101A vers:all/* (CVE-2026-3356) Remote Spectrum Monitor MS27102A vers:all/* (CVE-2026-3356) Remote Spectrum Monitor MS27103A vers:all/* (CVE-2026-3356) CVSS Vendor Equipment Vulnerabilities v3 9.8 Anritsu Anritsu Remote Spectrum Monitor Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Communications, Defense Industrial Base, Emergency Services, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-3356 The MS27102A Remote Spectrum Monitor is vulnerable to an authentication bypass that allows unauthorized users to access and manipulate its management interface. Because the device provides no mechanism to enable or configure authentication, the issue is inherent to its design rather than a deployment error. View CVE Details Affected Products Anritsu Remote Spectrum Monitor Vendor: Anritsu Product Version: Anritsu Remote Spectrum Monitor MS27100A: vers:all/*, Anritsu Remote Spectrum Monitor MS27101A: vers:all/*, Anritsu Remote Spectrum Monitor MS27102A: vers:all/*, Anritsu Remote Spectrum Monitor MS27103A: vers:all/* Product Status: known_affected Remediations Mitigation Anritsu has no plans to fix this issue. Anritsu recommends that users deploy Remote Spectrum Monitor within secure network environments to mitigate potential risks. Mitigation Users can contact Anritsu Technical Support (1-800-267-4878) for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-31 Date Revision Summary 2026-03-31 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3055 Citrix NetScaler Out-of-Bounds Read Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3055 Citrix NetScaler Out-of-Bounds Read Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-53521 F5 BIG-IP Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-53521 F5 BIG-IP Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

PTC Windchill Product Lifecycle Management

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. The following versions of PTC Windchill Product Lifecycle Management are affected: Windchill PDMLink 11.0_M030 (CVE-2026-4681) Windchill PDMLink 11.1_M020 (CVE-2026-4681) Windchill PDMLink 11.2.1.0 (CVE-2026-4681) Windchill PDMLink 12.0.2.0 (CVE-2026-4681) Windchill PDMLink 12.1.2.0…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. The following versions of PTC Windchill Product Lifecycle Management are affected: Windchill PDMLink 11.0_M030 (CVE-2026-4681) Windchill PDMLink 11.1_M020 (CVE-2026-4681) Windchill PDMLink 11.2.1.0 (CVE-2026-4681) Windchill PDMLink 12.0.2.0 (CVE-2026-4681) Windchill PDMLink 12.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.0.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.0.0 (CVE-2026-4681) Windchill PDMLink 13.1.1.0 (CVE-2026-4681) Windchill PDMLink 13.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.3.0 (CVE-2026-4681) FlexPLM 11.0_M030 (CVE-2026-4681) FlexPLM 11.1_M020 (CVE-2026-4681) FlexPLM 11.2.1.0 (CVE-2026-4681) FlexPLM 12.0.0.0 (CVE-2026-4681) FlexPLM 12.0.2.0 (CVE-2026-4681) FlexPLM 12.0.3.0 (CVE-2026-4681) FlexPLM 12.1.2.0 (CVE-2026-4681) FlexPLM 12.1.3.0 (CVE-2026-4681) FlexPLM 13.0.2.0 (CVE-2026-4681) FlexPLM 13.0.3.0 (CVE-2026-4681) CVSS Vendor Equipment Vulnerabilities v3 10 PTC PTC Windchill Product Lifecycle Management Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-4681 A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0. View CVE Details Affected Products PTC Windchill Product Lifecycle Management Vendor: PTC Product Version: PTC Windchill PDMLink: 11.0_M030, PTC Windchill PDMLink: 11.1_M020, PTC Windchill PDMLink: 11.2.1.0, PTC Windchill PDMLink: 12.0.2.0, PTC Windchill PDMLink: 12.1.2.0, PTC Windchill PDMLink: 13.0.2.0, PTC Windchill PDMLink: 13.1.0.0, PTC Windchill PDMLink: 13.1.1.0, PTC Windchill PDMLink: 13.1.2.0, PTC Windchill PDMLink: 13.1.3.0, PTC FlexPLM: 11.0_M030, PTC FlexPLM: 11.1_M020, PTC FlexPLM: 11.2.1.0, PTC FlexPLM: 12.0.0.0, PTC FlexPLM: 12.0.2.0, PTC FlexPLM: 12.0.3.0, PTC FlexPLM: 12.1.2.0, PTC FlexPLM: 12.1.3.0, PTC FlexPLM: 13.0.2.0, PTC FlexPLM: 13.0.3.0 Product Status: known_affected Remediations Mitigation PTC is aware of the issue and is actively developing a fix. In the meantime, PTC recommends applying the recommended workaround. Until official patches are available, customers must take urgent steps to safeguard their environments. Specifically: Protect any publicly accessible Windchill systems Vendor fix While publicly accessible Windchill and FlexPLM systems are at higher risk and require immediate attention, PTC strongly recommends applying the mitigation steps to all deployments, regardless of Internet exposure Vendor fix Apply the same precautions to FlexPLM deployments Vendor fix The following Apache and IIS HTTP Server configuration update should be IMMEDIATELY applied to every Windchill or FlexPLM system: Customers using Apache HTTP Server should only follow "Apache HTTP Server Configuration – Workaround Steps" section steps Mitigation Customers using Microsoft IIS should only follow "IIS Configuration - Workaround Steps" section steps Mitigation Please explicitly note that the same mitigation steps must also be applied on File Server / Replica Server configurations where applicable Mitigation For Windchill releases prior to 11.0 M030, workarounds may need to be altered to apply to unsupported previous releases Mitigation For Apache HTTP Server and IIS configuration workaround steps, please refer to the official advisory at:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Mitigation If immediate remediation is not feasible, additional guidance and remediation options are available:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments An anonymous source reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of PTC's CS466318 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33634 Aqua Security Trivy Embedded Malicious Code Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33634 Aqua Security Trivy Embedded Malicious Code Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

WAGO GmbH & Co. KG Industrial Managed Switches

View CSAF Summary An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. The following versions of WAGO GmbH & Co. KG Industrial Managed Switches are affected: WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813…
Read full source summary
View CSAF Summary An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. The following versions of WAGO GmbH & Co. KG Industrial Managed Switches are affected: WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware version V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware version V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S1 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) CVSS Vendor Equipment Vulnerabilities v3 10 WAGO WAGO GmbH & Co. KG Industrial Managed Switches Hidden Functionality Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-3587 An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. View CVE Details Affected Products WAGO GmbH & Co. KG Industrial Managed Switches Vendor: WAGO Product Version: WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware versions prior to V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware versions prior to V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware versions prior to V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware versions prior to V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware version V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware version V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware version V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-001, WAGO WAGO Firmware version V1.2.1.S1: WAGO_Hardware_852-1813/010-001 Product Status: known_affected Remediations Mitigation WAGO has identified the following specific workarounds and mitigations users can apply to reduce risk: Product Group: WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1813/010-001, WAGO Firmware installed on WAGO Hardware 852-1813/010-001): Please update your devices to the specified fixed Firmware version. Mitigation Lean Managed Switch 852-1812, Lean Managed Switch 852-1813, Lean Managed Switch 852-1813/000-001, Lean Managed Switch 852-1816, Lean Managed Switch 852-1812/010-000, Lean Managed Switch 852-1813/010-000, Lean Managed Switch 852-1816/010-000, Lean Managed Switch 852-1813/010-001: To eliminate the attack vector deactivate ssh and telnet on the device. Mitigation Industrial Managed Switch 852-303, Industrial Managed Switch 852-1305, Industrial Managed Switch 852-1305/000-001, Industrial Managed Switch 852-1505/000-001, Industrial Managed Switch 852-1505, Industrial Managed Switch 852-602, Industrial Managed Switch 852-603, Industrial Managed Switch 852-1605: To reduce the attack vector deactivate ssh and telnet on the devices. This ensures that the CLI is only accessible locally via RS232. Mitigation The following product versions have been fixed: Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.3.S1 installed on Lean Managed Switch 852-1813/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.8.S1 installed on Industrial Managed Switch 852-303 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1505/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.1.9.S1 installed on Industrial Managed Switch 852-1505 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-602 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-603 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.5.S1 installed on Industrial Managed Switch 852-1605 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-001 are fixed versions for CVE-2026-3587 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://www.wago.com/de-en/automation-technology/psirt Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://certvde.com/en/advisories/VDE-2026-020 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json Relevant CWE: CWE-912 Hidden Functionality Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments CERT@VDE coordination reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of WAGO GmbH & Co. KG VDE-2026-020 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

OpenCode Systems OC Messaging and Custom Messaging Gateway

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter. The following versions of OC Messaging and Custom Messaging Gateway are affected: OC Messaging 6.32.2 (CVE-2025-70614) Custom Messaging Gateway 6.32.2 (CVE-2025-70614) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter. The following versions of OC Messaging and Custom Messaging Gateway are affected: OC Messaging 6.32.2 (CVE-2025-70614) Custom Messaging Gateway 6.32.2 (CVE-2025-70614) CVSS Vendor Equipment Vulnerabilities v3 8.1 OpenCode Systems OC Messaging and Custom Messaging Gateway Improper Access Control Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: Bulgaria Vulnerabilities Expand All + CVE-2025-70614 OpenCode Systems Custom Messaging Gateway 6.32.2 contains a web access vulnerability allowing one authenticated user to gain access to another authenticated user's messages via a crafted identifier parameter. View CVE Details Affected Products OC Messaging and Custom Messaging Gateway Vendor: OpenCode Systems Product Version: OpenCode Systems OC Messaging: 6.32.2, OpenCode Systems Custom Messaging Gateway: 6.32.2 Product Status: known_affected Remediations Mitigation The vulnerability was identified by OpenCode Systems on January 5, 2026 and remediated on January 6, 2026 with the release of version 6.33.11. Mitigation For more information, contact OpenCode: https://opencode.com/about/contact-us https://opencode.com/about/contact-us Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N Acknowledgments Hussein Amer reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Publication 2026-04-16 2 Revision - Update to title and product information Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33017 Langflow Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33017 Langflow Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Pharos Controls Mosaic Show Controller

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges. The following versions of Pharos Controls Mosaic Show Controller are affected: Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pharos Controls Pharos Controls Mosaic Show Controller Missing Authentication for…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges. The following versions of Pharos Controls Mosaic Show Controller are affected: Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pharos Controls Pharos Controls Mosaic Show Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-2417 A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges. View CVE Details Affected Products Pharos Controls Mosaic Show Controller Vendor: Pharos Controls Product Version: Pharos Controls Mosaic Show Controller Firmware: 2.15.3 Product Status: known_affected Remediations Mitigation Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments James Tully reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication Legal Notice and Terms of Use