Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Apr 22, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Silex Technology SD-330AC and AMC Manager

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, cause a denial-of-service, or configuration information may be altered without authentication. The following versions of Silex Technology SD-330AC and AMC Manager are affected: SD-330AC <=1.42 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, cause a denial-of-service, or configuration information may be altered without authentication. The following versions of Silex Technology SD-330AC and AMC Manager are affected: SD-330AC <=1.42 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965) AMC Manager <=5.0.2 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965) CVSS Vendor Equipment Vulnerabilities v3 9.8 Silex Technology Silex Technology SD-330AC and AMC Manager Stack-based Buffer Overflow, Heap-based Buffer Overflow, Missing Authentication for Critical Function, Use of Hard-coded Cryptographic Key, Dependency on Vulnerable Third-Party Component, Use of a Broken or Risky Cryptographic Algorithm, Sensitive Information in Resource Not Removed Before Reuse, Incorrect Privilege Assignment, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of CRLF Sequences ('CRLF Injection'), Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-32955 A Stack-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-32956 A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32957 A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow uploads of arbitrary files to the device without authentication. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2026-32958 A Use of Hard-coded Cryptographic Key vulnerability in Silex Technology SD-330AC and AMC Manager could cause an administrative user to be directed to apply a fake firmware update. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N CVE-2015-5621 The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash). View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2015-5621: Disable SNMP service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-1395 Dependency on Vulnerable Third-Party Component Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-32959 A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to retrieve information via a man-in-the-middle attack. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-32960 A Sensitive Information in Resource Not Removed Before Reuse vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may allow the attacker to login to the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-226 Sensitive Information in Resource Not Removed Before Reuse Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N CVE-2026-32961 A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may cause a temporary denial-of-service (DoS) condition. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L CVE-2026-32962 A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to alter the device configuration without authentication. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2024-24487 An issue discovered in Silex Technology DS-600 Firmware v.1.4.1 allows a remote attacker to cause a denial of service via crafted UDP packets using the EXEC REBOOT SYSTEM command. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-266 Incorrect Privilege Assignment Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:H CVE-2026-32963 An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to trick a user into accessing a special web page and execute arbitrary script on the user's browser. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N CVE-2026-32964 An Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to inject arbitrary entries into the system configuration. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L CVE-2026-32965 An Initialization of a Resource with an Insecure Default vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker using the factory default configuration to configure the device using the null string password. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N Acknowledgments Francesco La Spina of Forescout Technologies reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary

View CSAF Summary RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) contains a vulnerability that could allow an attacker to escalate their own privileges. Siemens has released a new version for RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary are affected: RUGGEDCOM…
Read full source summary
View CSAF Summary RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) contains a vulnerability that could allow an attacker to escalate their own privileges. Siemens has released a new version for RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary are affected: RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) vers:intdot/<5.8 (CVE-2026-27668) CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary Incorrect Privilege Assignment Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-27668 User Administrators are allowed to administer groups they belong to. This could allow an authenticated User Administrator to escalate their own privileges and grant themselves access to any device group at any access level. View CVE Details Affected Products Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary Vendor: Siemens Product Version: RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) Product Status: known_affected Remediations Vendor fix Update to V5.8 or later version https://support.industry.siemens.com/cs/ww/en/view/110000841/ Relevant CWE: CWE-266 Incorrect Privilege Assignment Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-741509 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-741509 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens TPM 2.0

View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to perform an out-of-bound read, potentially leading to information disclosure or denial of service of the TPM. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes…
Read full source summary
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to perform an out-of-bound read, potentially leading to information disclosure or denial of service of the TPM. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens TPM 2.0 are affected: SIMATIC CN 4100 vers:all/* (CVE-2025-2884) SIMATIC Field PG M5 vers:all/* (CVE-2025-2884) SIMATIC Field PG M6 vers:all/* (CVE-2025-2884) SIMATIC IPC BX-32A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC BX-39A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC BX-56A vers:intdot/<32.01.09 (CVE-2025-2884) SIMATIC IPC BX-59A vers:intdot/<32.01.09 (CVE-2025-2884) SIMATIC IPC MD-57A vers:intdot/<30.01.10 (CVE-2025-2884) SIMATIC IPC PX-32A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC PX-39A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC PX-39A PRO vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC RW-528A vers:intdot/<34.01.02 (CVE-2025-2884) SIMATIC IPC RW-548A vers:intdot/<34.01.02 (CVE-2025-2884) SIMATIC IPC227E vers:all/* (CVE-2025-2884) SIMATIC IPC277E vers:all/* (CVE-2025-2884) SIMATIC IPC427E vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC477E vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC477E PRO vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC627E vers:all/* (CVE-2025-2884) SIMATIC IPC647E vers:all/* (CVE-2025-2884) SIMATIC IPC677E vers:all/* (CVE-2025-2884) SIMATIC IPC847E vers:all/* (CVE-2025-2884) SIMATIC ITP1000 vers:all/* (CVE-2025-2884) SIPLUS IPC427E vers:intdot/<21.01.20 (CVE-2025-2884) CVSS Vendor Equipment Vulnerabilities v3 6.6 Siemens Siemens TPM 2.0 Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-2884 TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0 View CVE Details Affected Products Siemens TPM 2.0 Vendor: Siemens Product Version: SIMATIC CN 4100, SIMATIC Field PG M5, SIMATIC Field PG M6, SIMATIC IPC BX-32A, SIMATIC IPC BX-39A, SIMATIC IPC BX-56A, SIMATIC IPC BX-59A, SIMATIC IPC MD-57A, SIMATIC IPC PX-32A, SIMATIC IPC PX-39A, SIMATIC IPC PX-39A PRO, SIMATIC IPC RW-528A, SIMATIC IPC RW-548A, SIMATIC IPC227E, SIMATIC IPC277E, SIMATIC IPC427E, SIMATIC IPC477E, SIMATIC IPC477E PRO, SIMATIC IPC627E, SIMATIC IPC647E, SIMATIC IPC677E, SIMATIC IPC847E, SIMATIC ITP1000, SIPLUS IPC427E Product Status: known_affected Remediations No fix planned Currently no fix is planned None available Currently no fix is available Vendor fix Update to V21.01.20 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V29.01.09 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V30.01.10 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V32.01.09 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V34.01.02 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.6 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-628843 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-628843 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SenseLive X3050

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device. The following versions of SenseLive X3050 are affected: X3050 V1.523 (CVE-2026-40630, CVE-2026-25720, CVE-2026-35503, CVE-2026-39462, CVE-2026-27843, CVE-2026-40431, CVE-2026-40623, CVE-2026-27841, CVE-2026-40620, CVE-2026-35064, CVE-2026-25775) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device. The following versions of SenseLive X3050 are affected: X3050 V1.523 (CVE-2026-40630, CVE-2026-25720, CVE-2026-35503, CVE-2026-39462, CVE-2026-27843, CVE-2026-40431, CVE-2026-40623, CVE-2026-27841, CVE-2026-40620, CVE-2026-35064, CVE-2026-25775) CVSS Vendor Equipment Vulnerabilities v3 9.8 SenseLive SenseLive X3050 Authentication Bypass Using an Alternate Path or Channel, Insufficient Session Expiration, Use of Hard-coded Credentials, Insufficiently Protected Credentials, Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information, Missing Authorization, Cross-Site Request Forgery (CSRF) Background Critical Infrastructure Sectors: Critical Manufacturing, Water and Wastewater, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-40630 A vulnerability in the X3050's web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25720 A vulnerability exists in the X3050's web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N CVE-2026-35503 A vulnerability in the X3050's web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-39462 A vulnerability exists in the X3050's web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-27843 A vulnerability exists in the X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-40431 A vulnerability exists in the X3050's web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-40623 A vulnerability in the X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2026-27841 A vulnerability in the X3050's web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user's browser to submit unauthorized configuration requests to the device. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-352 Cross-Site Request Forgery (CSRF) Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H CVE-2026-40620 A vulnerability in the X3050's embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-35064 A vulnerability in the X3050's management ecosystem allows unauthenticated discovery of deployed units through the vendor's management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-25775 A vulnerability in X3050's remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Jithin Nambiar J reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Analytics Toolkit

View CSAF Summary Multiple Siemens applications are affected by improper certificate validation in Siemens Analytics Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Analytics Toolkit are affected: Siemens Software Center…
Read full source summary
View CSAF Summary Multiple Siemens applications are affected by improper certificate validation in Siemens Analytics Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Analytics Toolkit are affected: Siemens Software Center vers:intdot/<3.5.8.2 (CVE-2025-40745) Simcenter 3D vers:intdot/<2506.6000 (CVE-2025-40745) Simcenter Femap vers:intdot/<2506.0002 (CVE-2025-40745) Simcenter STAR-CCM+ vers:intdot/<2602 (CVE-2025-40745) Solid Edge SE2025 Solid Edge SE2026 Tecnomatix Plant Simulation vers:intdot/<2504.0008 (CVE-2025-40745) CVSS Vendor Equipment Vulnerabilities v3 3.7 Siemens Siemens Analytics Toolkit Improper Certificate Validation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40745 Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. View CVE Details Affected Products Siemens Analytics Toolkit Vendor: Siemens Product Version: Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Solid Edge SE2025, Solid Edge SE2026, Tecnomatix Plant Simulation Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 13 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 04 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V2504.0008 or later version https://support.sw.siemens.com/product/297028302/ Vendor fix Update to V2506.0002 or later version https://support.sw.siemens.com/product/275652363/ Vendor fix Update to V2506.6000 or later version https://support.sw.siemens.com/product/289054037/ Vendor fix Update to V2602 or later version https://support.sw.siemens.com/product/226870983/ Vendor fix Update to V3.5.8.2 or later version https://www.sw.siemens.com/en-US/siemens-software-center/ Relevant CWE: CWE-295 Improper Certificate Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-981622 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-981622 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SCALANCE

View CSAF Summary SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version. The following versions of Siemens SCALANCE are affected: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141,…
Read full source summary
View CSAF Summary SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version. The following versions of Siemens SCALANCE are affected: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) vers:intdot/<6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373) CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens SCALANCE Missing Authentication for Critical Function, Improper Authentication, Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Improper Validation of Integrity Check Value, Improper Input Validation, Out-of-bounds Read, Loop with Unreachable Exit Condition ('Infinite Loop'), Missing Authorization, Allocation of Resources Without Limits or Throttling, Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) Background Critical Infrastructure Sectors: Communications, Information Technology, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2020-24588 The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Mitigation Disable A-MSDU, if possible Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N CVE-2020-26139 An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-287 Improper Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2020-26140 An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-26141 An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-354 Improper Validation of Integrity Check Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-26143 An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-26144 An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-26146 An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-26147 An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Mitigation As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N CVE-2021-3712 ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL's own "d2i" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the "data" and "length" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the "data" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y). View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H CVE-2022-0778 The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-31765 Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2022-36323 Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2022-36324 Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2022-36325 Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2023-44373 Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323. View CVE Details Affected Products Siemens SCALANCE Vendor: Siemens Product Version: SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) Product Status: known_affected Remediations Vendor fix Update to V6.6.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109996102/ Relevant CWE: CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-019200 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-019200 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hardy Barth Salia EV Charge Controller

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution. The following versions of Hardy Barth Salia EV Charge Controller are affected: Salia Board Firmware <=2.3.81 (CVE-2025-5873, CVE-2025-10371) CVSS Vendor Equipment Vulnerabilities v3 7.3 Hardy Barth Hardy Barth Salia EV Charge Controller Unrestricted…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution. The following versions of Hardy Barth Salia EV Charge Controller are affected: Salia Board Firmware <=2.3.81 (CVE-2025-5873, CVE-2025-10371) CVSS Vendor Equipment Vulnerabilities v3 7.3 Hardy Barth Hardy Barth Salia EV Charge Controller Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-5873 A vulnerability was found in eCharge Hardy Barth Salia PLCC 2.3.81. It has been declared as critical. This vulnerability affects unknown code of the file /firmware.php of the component Web UI. The manipulation of the argument media leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Hardy Barth Salia EV Charge Controller Vendor: Hardy Barth Product Version: Hardy Barth Salia Board Firmware: <=2.3.81 Product Status: known_affected Remediations Mitigation Hardy Barth did not respond to CISA's request for coordination. Mitigation Contact Hardy Barth using their contact page here: https://www.hardy-barth.de/de/kontakt for more information. https://www.hardy-barth.de/de/kontakt Mitigation Alternatively, Hardy Barth can also be contacted through their eCharge brand here: https://www.echarge.de/en/contact_company https://www.echarge.de/en/contact_company Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L CVE-2025-10371 A security flaw has been discovered in eCharge Hardy Barth Salia PLCC 2.3.81. This issue affects some unknown processing of the file /api.php. The manipulation of the argument setrfidlist results in unrestricted upload. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. View CVE Details Affected Products Hardy Barth Salia EV Charge Controller Vendor: Hardy Barth Product Version: Hardy Barth Salia Board Firmware: <=2.3.81 Product Status: known_affected Remediations Mitigation Hardy Barth did not respond to CISA's request for coordination. Mitigation Contact Hardy Barth using their contact page here: https://www.hardy-barth.de/de/kontakt for more information. https://www.hardy-barth.de/de/kontakt Mitigation Alternatively, Hardy Barth can also be contacted through their eCharge brand here: https://www.echarge.de/en/contact_company https://www.echarge.de/en/contact_company Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L Acknowledgments CISA discovered a public Proof of Concept (PoC) as authored by YZS17 and reported it to Hardy Barth Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SINEC NMS

View CSAF Summary Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following…
Read full source summary
View CSAF Summary Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment Vulnerabilities v3 7.3 Siemens Siemens SINEC NMS Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-24032 The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. (ZDI-CAN-27564) View CVE Details Affected Products Siemens SINEC NMS Vendor: Siemens Product Version: SINEC NMS Product Status: known_affected Remediations Vendor fix Update to V4.0 SP3 or later version https://support.industry.siemens.com/cs/ww/en/view/110000760/ Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-801704 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-801704 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Zero Motorcycles Firmware

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to pair via Bluetooth with a motorcycle, gaining unauthorized access to all Bluetooth functions, including changing the firmware. The following versions of Zero Motorcycles Firmware are affected: Zero Motorcycles firmware <=44 (CVE-2026-1354) CVSS Vendor Equipment Vulnerabilities v3 6.4 Zero Motorcycles Zero Motorcycles Firmware…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to pair via Bluetooth with a motorcycle, gaining unauthorized access to all Bluetooth functions, including changing the firmware. The following versions of Zero Motorcycles Firmware are affected: Zero Motorcycles firmware <=44 (CVE-2026-1354) CVSS Vendor Equipment Vulnerabilities v3 6.4 Zero Motorcycles Zero Motorcycles Firmware Key Exchange without Entity Authentication Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1354 Zero Motorcycles firmware versions 44 and prior enable an attacker to forcibly pair a device with the motorcycle via Bluetooth. Once paired, an attacker can utilize over-the-air firmware updating functionality to potentially upload malicious firmware to the motorcycle. The motorcycle must first be in Bluetooth pairing mode, and the attacker must be in proximity of the vehicle and understand the full pairing process, to be able to pair their device with the vehicle. The attacker's device must remain paired with and in proximity of the motorcycle for the entire duration of the firmware update. View CVE Details Affected Products Zero Motorcycles Firmware Vendor: Zero Motorcycles Product Version: Zero Motorcycles Zero Motorcycles firmware: <=44 Product Status: known_affected Remediations Mitigation Zero Motorcycles has investigated this report and cautions users to pair their mobile device to their vehicle in a safe location where they can be sure no one else will try to pair at the same time. Once initiated, complete the full pairing process and confirm it is successful. Store physical keys in a secure location and do not leave the bike unattended with the key in the "ON" position. Zero Motorcycles plans to address this issue in a firmware update scheduled for release in May 2026. Update the firmware to the latest available version. Relevant CWE: CWE-322 Key Exchange without Entity Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H Acknowledgments Persephone Karnstein of Bureau Veritas Cybersecurity North America reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SINEC NMS

View CSAF Summary SINEC NMS before V4.0 SP3 contains an Authorization Bypass vulnerability that could allow an attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment…
Read full source summary
View CSAF Summary SINEC NMS before V4.0 SP3 contains an Authorization Bypass vulnerability that could allow an attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens SINEC NMS Authorization Bypass Through User-Controlled Key Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25654 Affected products do not properly validate user authorization when processing password reset requests. This could allow an authenticated remote attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. View CVE Details Affected Products Siemens SINEC NMS Vendor: Siemens Product Version: SINEC NMS Product Status: known_affected Remediations Mitigation Limit network access to trusted users and systems only Vendor fix Update to V4.0 SP3 or later version https://support.industry.siemens.com/cs/ww/en/view/110000760/ Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-605717 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-605717 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Industrial Edge Management

View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens…
Read full source summary
View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Pro V1 vers:intdot/>=1.7.6|<1.15.17 (CVE-2026-33892) Industrial Edge Management Pro V2 vers:intdot/>=2.0.0|<2.1.1 (CVE-2026-33892) Industrial Edge Management Virtual vers:intdot/>=2.2.0|<2.8.0 (CVE-2026-33892) CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens Industrial Edge Management Authentication Bypass by Primary Weakness Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-33892 Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected. View CVE Details Affected Products Siemens Industrial Edge Management Vendor: Siemens Product Version: Industrial Edge Management Pro V1, Industrial Edge Management Pro V2, Industrial Edge Management Virtual Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.15.17 or later version https://iehub.eu1.edge.siemens.cloud/ Vendor fix Update to V2.1.1 or later version https://iehub.eu1.edge.siemens.cloud/ Vendor fix Update to V2.8.0 or later version https://iehub.eu1.edge.siemens.cloud/ Relevant CWE: CWE-305 Authentication Bypass by Primary Weakness Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-609469 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-609469 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)

View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access…
Read full source summary
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) are affected: RUGGEDCOM CROSSBOW Station Access Controller (SAC) vers:intdot/<5.8 (CVE-2025-6965) CVSS Vendor Equipment Vulnerabilities v3 7.7 Siemens Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Numeric Truncation Error Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-6965 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above. View CVE Details Affected Products Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Vendor: Siemens Product Version: RUGGEDCOM CROSSBOW Station Access Controller (SAC) Product Status: known_affected Remediations Vendor fix Update to V5.8 or later version https://support.industry.siemens.com/cs/ww/en/view/110000841/ Relevant CWE: CWE-197 Numeric Truncation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-225816 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-225816 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Eight Known Exploited Vulnerabilities to Catalog

CISA has added eight new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-27351 PaperCut NG/MF Improper Authentication Vulnerability CVE-2024-27199 JetBrains TeamCity Relative Path Traversal Vulnerability CVE-2025-2749 Kentico Xperience Path Traversal Vulnerability CVE-2025-32975 Quest KACE Systems Management Appliance (SMA) Improper…
Read full source summary
CISA has added eight new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-27351 PaperCut NG/MF Improper Authentication Vulnerability CVE-2024-27199 JetBrains TeamCity Relative Path Traversal Vulnerability CVE-2025-2749 Kentico Xperience Path Traversal Vulnerability CVE-2025-32975 Quest KACE Systems Management Appliance (SMA) Improper Authentication Vulnerability CVE-2025-48700 Synacor Zimbra Collaboration Suite (ZCS) Cross-site Scripting Vulnerability CVE-2026-20122 Cisco Catalyst SD-WAN Manager Incorrect Use of Privileged APIs Vulnerability CVE-2026-20128 Cisco Catalyst SD-WAN Manager Storing Passwords in a Recoverable Format Vulnerability CVE-2026-20133 Cisco Catalyst SD-WAN Manager Exposure of Sensitive Information to an Unauthorized Actor Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

​​Supply Chain Compromise Impacts Axios Node Package Manager​

The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this alert to provide guidance in response to the software supply chain compromise of the Axios node package manager (npm).1 Axios is an HTTP client for JavaScript that developers commonly use in Node.js and browser environments. On March 31, 2026, two npm packages for versions axios@1.14.1 and axios@0.30.4 of Axios npm injected the malicious…
Read full source summary
The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this alert to provide guidance in response to the software supply chain compromise of the Axios node package manager (npm).1 Axios is an HTTP client for JavaScript that developers commonly use in Node.js and browser environments. On March 31, 2026, two npm packages for versions axios@1.14.1 and axios@0.30.4 of Axios npm injected the malicious dependency plain-crypto-js@4.2.1 that downloads multi-stage payloads from cyber threat actor infrastructure, including a remote access trojan.2 CISA urges organizations to implement the following recommendations to detect and remediate a potential compromise: Monitor and review code repositories, continuous integration/continuous delivery (CI/CD) pipelines, and developer machines that ran npm install or npm update with the compromised Axios version. Search for cached versions of affected dependencies in artifact repositories and dependency management tools. Pin npm package dependency versions to known safe releases. If compromised dependencies are identified, revert the environment to a known safe state. Downgrade to axios@1.14.0 or axios@0.30.3 and delete node_modules/plain-crypto-js/. Rotate/revoke credentials that may have been exposed on affected systems or pipelines (e.g., version control system [VCS] tokens, CI/CD secrets, cloud keys, npm tokens, and Secure Shell [SSH] keys). For ephemeral CI jobs, rotate all secrets injected into the compromised run. Monitor for unexpected child processes and anomalous network behavior, specifically during npm install or npm update. Block and monitor outbound connections to Sfrclak[.]com domains. Conduct continuous indicator searches and endpoint detection and response (EDR) hunts to confirm no indicators of compromise (IOCs) remain; ensure no further egress to the command and control (C2). In addition, CISA recommends organizations using Axios npm: Mandate phishing-resistant multifactor authentication (MFA) on all developer accounts, especially for critical platforms. Set ignore-scripts=true in the .npmrc configuration file, which prevents potentially malicious scripts from executing during npm install packages. Set min-release-age=7 in the .npmrc configuration file to only install packages that have been published for at least seven days, which helps avoid installation of packages that may not be completely vetted or are potentially malicious. Establish and maintain a baseline of normal execution behavior for tools that use Axios. Alert when a dependency behaves differently (e.g., building containers, enabling shells, executing commands) and trace outbound network activity for anomalous connections. See the following resources for additional guidance on this compromise: GitHub: Post Mortem: axios npm supply chain compromise #10636 Microsoft: Mitigating the Axios npm supply chain compromise StepSecurity: axios Compromised on npm - Malicious Versions Drop Remote Access Trojan npm Docs: Securing your code Socket: Supply Chain Attack on Axios Pulls Malicious Dependency from npm Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Notes 1 “Post Mortem: axios npm supply chain compromise,” axios GitHub, Issue #10636, March 31, 2026, https://github.com/axios/axios/issues/10636. 2 “Mitigating the Axios npm supply chain compromise,” Microsoft Threat Intelligence and Microsoft Defender Security Research Team, April 1, 2026, https://www.microsoft.com/en-us/security/blog/2026/04/01/mitigating-the-axios-npm-supply-chain-compromise/.
· CISA Cybersecurity Advisory

AVEVA Pipeline Simulation

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify simulation parameters, training configuration and training records. The following versions of AVEVA Pipeline Simulation are affected: Pipeline Simulation <=2025_SP1_build_7.1.9497.6351 CVSS Vendor Equipment Vulnerabilities v3 9.1 AVEVA AVEVA Pipeline Simulation Missing Authorization Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify simulation parameters, training configuration and training records. The following versions of AVEVA Pipeline Simulation are affected: Pipeline Simulation <=2025_SP1_build_7.1.9497.6351 CVSS Vendor Equipment Vulnerabilities v3 9.1 AVEVA AVEVA Pipeline Simulation Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-5387 The vulnerability, if exploited, could allow an unauthenticated miscreant to perform operations intended only for Simulator Instructor or Simulator Developer (Administrator) roles, resulting in privilege escalation with potential for modification of simulation parameters, training configuration, and training records. View CVE Details Affected Products AVEVA Pipeline Simulation Vendor: AVEVA Product Version: AVEVA Pipeline Simulation: <=2025_SP1_build_7.1.9497.6351 Product Status: known_affected Remediations Vendor fix All affected versions can be fixed by upgrading to AVEVA Pipeline Simulation 2025 SP1 P01 (build 7.1.9580.8513) or higher. (https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f) https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f Mitigation For more information, please see AVEVA's security bulletin AVEVA-2026-004 (https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf). https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf Vendor fix Restrict Network Access: Implement host-based and/or network firewall controls on all nodes hosting the Pipeline Simulation Server API to ensure that only trusted Pipeline Simulation client systems are permitted to establish connections. Mitigation Enforce Secure Communication: Enable TLS for all API communications and ensure that server certificates are properly managed and protected to reduce the risk of manipulator-in-the-middle(MitM) attacks and tampering with data in transit. Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments AVEVA reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Republication of AVEVA-2026-004 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Delta Electronics ASDA-Soft

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics ASDA-Soft are affected: ASDA-Soft <=V7.2.2.0 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics ASDA-Soft Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics ASDA-Soft are affected: ASDA-Soft <=V7.2.2.0 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics ASDA-Soft Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-5726 A stack-based buffer overflow vulnerability is triggered in ASDA-Soft version 7.2.0.0 during the parsing of malformed .par files. View CVE Details Affected Products Delta Electronics ASDA-Soft Vendor: Delta Electronics Product Version: Delta Electronics ASDA-Soft: <=V7.2.2.0 Product Status: known_affected Remediations Vendor fix Delta Electronics recommends users download and upgrade ASDA-Soft to v7.2.6.0 or later. If you have any product-related support concerns, contact Delta via the portal page at https://www.deltaww.com/en-US/service-support/contact-us?type=1 for any information or materials you may require. https://www.deltaww.com/en-US/service-support/contact-us?type=1 Mitigation Delta Electronics provides the following general recommendations: Do not click on untrusted internet links or open unsolicited attachments in emails. Avoid exposing control systems and equipment to the Internet. Place control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use a secure access method, such as a virtual private network (VPN). Mitigation For more information, see Delta Electronics advisory Delta-PCSA-2026-00007 athttps://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Feng Xiong of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Horner Automation Cscape and XL4, XL7 PLC

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services. The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected: Cscape v10.0 XL7 PLC v15.60 XL4 PLC v16.32.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Horner Automation Horner Automation Cscape and XL4, XL7 PLC Weak Password Requirements Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services. The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected: Cscape v10.0 XL7 PLC v15.60 XL4 PLC v16.32.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Horner Automation Horner Automation Cscape and XL4, XL7 PLC Weak Password Requirements Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6284 An attacker with network access to the PLC is able to brute force discover passwords to gain unauthorized access to systems and services. The limited password complexity and no password input limiters makes brute force password enumeration possible. View CVE Details Affected Products Horner Automation Cscape and XL4, XL7 PLC Vendor: Horner Automation Product Version: Horner Automation Cscape: v10.0, Horner Automation XL7 PLC: v15.60, Horner Automation XL4 PLC: v16.32.0 Product Status: known_affected Remediations Vendor fix Horner Automation recommends users update to Cscape v10.2 SP2 or later. Horner Automation has also released the latest firmware for both XL4 and XL7 PLCs. Horner recommends users update to the latest version of the firmware. https://hornerautomation.com/cscape-software-free/cscape-software/. https://hornerautomation.com/cscape-software-free/cscape-software/ Mitigation For more information, see Horner Automation's release notes. Relevant CWE: CWE-521 Weak Password Requirements Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments An anonymous researcher reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Anviz Multiple Products

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to conduct reconnaissance, capture or decrypt sensitive data, alter device configurations, gain unauthorized administrative or root‑level access, execute arbitrary code, compromise credentials or communications, and ultimately obtain full control over affected devices. The following versions of Anviz Multiple Products are…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to conduct reconnaissance, capture or decrypt sensitive data, alter device configurations, gain unauthorized administrative or root‑level access, execute arbitrary code, compromise credentials or communications, and ultimately obtain full control over affected devices. The following versions of Anviz Multiple Products are affected: CX2 Lite Firmware vers:all/* (CVE-2026-32648, CVE-2026-40461, CVE-2026-35682, CVE-2026-35546, CVE-2026-40066, CVE-2026-33569) CX7 Firmware vers:all/* (CVE-2026-33093, CVE-2026-35061, CVE-2026-32648, CVE-2026-40461, CVE-2026-35546, CVE-2026-40066, CVE-2026-32324, CVE-2026-31927, CVE-2026-33569) CrossChex Standard vers:all/* (CVE-2026-40434, CVE-2026-32650) CVSS Vendor Equipment Vulnerabilities v3 9.8 Anviz Anviz Multiple Products Missing Authorization, Missing Authentication for Critical Function, Improper Neutralization of Special Elements used in a Command ('Command Injection'), Download of Code Without Integrity Check, Use of Hard-coded Cryptographic Key, Relative Path Traversal, Cleartext Transmission of Sensitive Information, Improper Verification of Source of a Communication Channel, Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Defense Industrial Base, Energy, Financial Services, Food and Agriculture, Government Services and Facilities, Healthcare and Public Health, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-33093 CX7 is vulnerable to an unauthenticated POST to the device that captures a photo with the front facing camera, exposing visual information about the deployment environment. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-35061 CX7 is vulnerable to the most recently captured test photo that can be retrieved without authentication, revealing sensitive operational imagery. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-32648 CX2 Lite and CX7 are vulnerable to unauthenticated access that discloses debug configuration details (e.g., SSH/RTTY status), assisting attackers in reconnaissance against the device. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-40461 CX2 Lite and CX7 are vulnerable to unauthenticated POST requests that modify debug settings (e.g., enabling SSH), allowing unauthorized state changes that can facilitate later compromise. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2026-35682 CX2 Lite is vulnerable to an authenticated command injection via a filename parameter that enables arbitrary command execution (e.g., starting telnetd), resulting in root‑level access. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-35546 CX2 Lite and CX7 are vulnerable to unauthenticated firmware uploads. This causes crafted archives to be accepted, enabling attackers to plant and execute code and obtain a reverse shell. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-40066 CX2 Lite and CX7 are vulnerable to unverified update packages that can be uploaded. The device unpacks and executes a script resulting in unauthenticated remote code execution. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-494 Download of Code Without Integrity Check Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-32324 CX7 is vulnerable because the application embeds reusable certificate/key material, enabling decryption of MQTT traffic and potential interaction with device messaging channels at scale. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2026-31927 CX7 is vulnerable to an authenticated CSV upload which allows path traversal to overwrite arbitrary files (e.g., /etc/shadow), enabling unauthorized SSH access when combined with debug‑setting changes. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.9 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N CVE-2026-33569 CX2 Lite and CX7 administrative sessions occur over HTTP, enabling on‑path attackers to sniff credentials and session data, which can be used to compromise the device. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N CVE-2026-40434 CrossChex Standard lacks source verification in the client/server channel, enabling TCP packet injection by an attacker on the same network to alter or disrupt application traffic. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CrossChex Standard: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-32650 CrossChex Standard is vulnerable when an attacker manipulates the TDS7 PreLogin to disable encryption, causing database credentials to be sent in plaintext and enabling unauthorized database access. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CrossChex Standard: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-757 Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments An anonymous researcher reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-34197 Apache ActiveMQ Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-34197 Apache ActiveMQ Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2009-0238 Microsoft Office Remote Code Execution Vulnerability CVE-2026-32201 Microsoft SharePoint Server Improper Input Validation Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2009-0238 Microsoft Office Remote Code Execution Vulnerability CVE-2026-32201 Microsoft SharePoint Server Improper Input Validation Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Browse saved snapshots