[
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-10",
        "title": "Silex Technology SD-330AC and AMC Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-10",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-10.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, cause a denial-of-service, or configuration information may be altered without authentication.</strong></p>\n<p>The following versions of Silex Technology SD-330AC and AMC Manager are affected:</p>\n<ul>\n<li>SD-330AC &lt;=1.42 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965)</li>\n<li>AMC Manager &lt;=5.0.2 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Silex Technology</td>\n<td>Silex Technology SD-330AC and AMC Manager</td>\n<td>Stack-based Buffer Overflow, Heap-based Buffer Overflow, Missing Authentication for Critical Function, Use of Hard-coded Cryptographic Key, Dependency on Vulnerable Third-Party Component, Use of a Broken or Risky Cryptographic Algorithm, Sensitive Information in Resource Not Removed Before Reuse, Incorrect Privilege Assignment, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of CRLF Sequences ('CRLF Injection'), Initialization of a Resource with an Insecure Default</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32955</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Stack-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32955\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32956</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32956\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32957</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow uploads of arbitrary files to the device without authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32957\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32958</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Use of Hard-coded Cryptographic Key vulnerability in Silex Technology SD-330AC and AMC Manager could cause an administrative user to be directed to apply a fake firmware update.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32958\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-5621</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-5621\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2015-5621: Disable SNMP service.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1395.html\">CWE-1395 Dependency on Vulnerable Third-Party Component</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32959</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to retrieve information via a man-in-the-middle attack.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32959\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/327.html\">CWE-327 Use of a Broken or Risky Cryptographic Algorithm</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32960</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Sensitive Information in Resource Not Removed Before Reuse vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may allow the attacker to login to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32960\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/226.html\">CWE-226 Sensitive Information in Resource Not Removed Before Reuse</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32961</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may cause a temporary denial-of-service (DoS) condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32961\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32962</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to alter the device configuration without authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32962\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-24487</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue discovered in Silex Technology DS-600 Firmware v.1.4.1 allows a remote attacker to cause a denial of service via crafted UDP packets using the EXEC REBOOT SYSTEM command.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-24487\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/266.html\">CWE-266 Incorrect Privilege Assignment</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32963</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to trick a user into accessing a special web page and execute arbitrary script on the user's browser.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32963\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32964</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to inject arbitrary entries into the system configuration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32964\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/93.html\">CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32965</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Initialization of a Resource with an Insecure Default vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker using the factory default configuration to configure the device using the null string password.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32965\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Silex Technology SD-330AC and AMC Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Silex Technology</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Silex Technology SD-330AC: &lt;=1.42, Silex Technology AMC Manager: &lt;=5.0.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later</p>\n<p><strong>Vendor fix</strong><br>AMC Manager Ver.5.1.0 or later</p>\n<p><strong>Mitigation</strong><br>CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface.</p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/en/2026-001\">https://www.silex.jp/support/security-advisories/en/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001).<br><a href=\"https://www.silex.jp/support/security-advisories/2026-001\">https://www.silex.jp/support/security-advisories/2026-001</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/en/vu/JVNVU94271449/\">https://jvn.jp/en/vu/JVNVU94271449/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/).<br><a href=\"https://jvn.jp/vu/JVNVU94271449/\">https://jvn.jp/vu/JVNVU94271449/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1188.html\">CWE-1188 Initialization of a Resource with an Insecure Default</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Francesco La Spina of Forescout Technologies reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-21</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-02",
        "title": "Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) contains a vulnerability that could allow an attacker to escalate their own privileges. Siemens has released a new version for RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary are affected:</p>\n<ul>\n<li>RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) vers:intdot/&lt;5.8 (CVE-2026-27668)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Siemens</td>\n<td>Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary</td>\n<td>Incorrect Privilege Assignment</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27668</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>User Administrators are allowed to administer groups they belong to. This could allow an authenticated User Administrator to escalate their own privileges and grant themselves access to any device group at any access level.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27668\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V5.8 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000841/\">https://support.industry.siemens.com/cs/ww/en/view/110000841/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/266.html\">CWE-266 Incorrect Privilege Assignment</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-741509 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-741509 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-01",
        "title": "Siemens TPM 2.0",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>The products listed below contain a vulnerability that could allow an attacker to perform an out-of-bound read, potentially leading to information disclosure or denial of service of the TPM. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens TPM 2.0 are affected:</p>\n<ul>\n<li>SIMATIC CN 4100 vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC Field PG M5 vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC Field PG M6 vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC BX-32A vers:intdot/&lt;29.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC BX-39A vers:intdot/&lt;29.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC BX-56A vers:intdot/&lt;32.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC BX-59A vers:intdot/&lt;32.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC MD-57A vers:intdot/&lt;30.01.10 (CVE-2025-2884)</li>\n<li>SIMATIC IPC PX-32A vers:intdot/&lt;29.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC PX-39A vers:intdot/&lt;29.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC PX-39A PRO vers:intdot/&lt;29.01.09 (CVE-2025-2884)</li>\n<li>SIMATIC IPC RW-528A vers:intdot/&lt;34.01.02 (CVE-2025-2884)</li>\n<li>SIMATIC IPC RW-548A vers:intdot/&lt;34.01.02 (CVE-2025-2884)</li>\n<li>SIMATIC IPC227E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC277E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC427E vers:intdot/&lt;21.01.20 (CVE-2025-2884)</li>\n<li>SIMATIC IPC477E vers:intdot/&lt;21.01.20 (CVE-2025-2884)</li>\n<li>SIMATIC IPC477E PRO vers:intdot/&lt;21.01.20 (CVE-2025-2884)</li>\n<li>SIMATIC IPC627E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC647E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC677E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC IPC847E vers:all/* (CVE-2025-2884)</li>\n<li>SIMATIC ITP1000 vers:all/* (CVE-2025-2884)</li>\n<li>SIPLUS IPC427E vers:intdot/&lt;21.01.20 (CVE-2025-2884)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.6</td>\n<td>Siemens</td>\n<td>Siemens TPM 2.0</td>\n<td>Out-of-bounds Read</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-2884</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2884\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens TPM 2.0</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SIMATIC CN 4100, SIMATIC Field PG M5, SIMATIC Field PG M6, SIMATIC IPC BX-32A, SIMATIC IPC BX-39A, SIMATIC IPC BX-56A, SIMATIC IPC BX-59A, SIMATIC IPC MD-57A, SIMATIC IPC PX-32A, SIMATIC IPC PX-39A, SIMATIC IPC PX-39A PRO, SIMATIC IPC RW-528A, SIMATIC IPC RW-548A, SIMATIC IPC227E, SIMATIC IPC277E, SIMATIC IPC427E, SIMATIC IPC477E, SIMATIC IPC477E PRO, SIMATIC IPC627E, SIMATIC IPC647E, SIMATIC IPC677E, SIMATIC IPC847E, SIMATIC ITP1000, SIPLUS IPC427E</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>None available</strong><br>Currently no fix is available</p>\n<p><strong>Vendor fix</strong><br>Update to V21.01.20 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109763408/\">https://support.industry.siemens.com/cs/ww/en/view/109763408/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V29.01.09 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109763408/\">https://support.industry.siemens.com/cs/ww/en/view/109763408/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V30.01.10 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109763408/\">https://support.industry.siemens.com/cs/ww/en/view/109763408/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V32.01.09 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109763408/\">https://support.industry.siemens.com/cs/ww/en/view/109763408/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V34.01.02 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109763408/\">https://support.industry.siemens.com/cs/ww/en/view/109763408/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-628843 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-628843 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12",
        "title": "SenseLive X3050",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device.</strong></p>\n<p>The following versions of SenseLive X3050 are affected:</p>\n<ul>\n<li>X3050 V1.523 (CVE-2026-40630, CVE-2026-25720, CVE-2026-35503, CVE-2026-39462, CVE-2026-27843, CVE-2026-40431, CVE-2026-40623, CVE-2026-27841, CVE-2026-40620, CVE-2026-35064, CVE-2026-25775)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>SenseLive</td>\n<td>SenseLive X3050</td>\n<td>Authentication Bypass Using an Alternate Path or Channel, Insufficient Session Expiration, Use of Hard-coded Credentials, Insufficiently Protected Credentials, Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information, Missing Authorization, Cross-Site Request Forgery (CSRF)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Water and Wastewater, Energy, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>India</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40630</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40630\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/288.html\">CWE-288 Authentication Bypass Using an Alternate Path or Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25720</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in the X3050's web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25720\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35503</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35503\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-39462</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in the X3050's web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-39462\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27843</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in the X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27843\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40431</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in the X3050's web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40431\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40623</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40623\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27841</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user's browser to submit unauthorized configuration requests to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27841\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/352.html\">CWE-352 Cross-Site Request Forgery (CSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40620</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40620\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35064</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in the X3050's management ecosystem allows unauthenticated discovery of deployed units through the vendor's management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35064\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25775</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in X3050's remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25775\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>SenseLive X3050</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>SenseLive</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SenseLive X3050: V1.523</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact<br><a href=\"https://senselive.io/contact\">https://senselive.io/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jithin Nambiar J reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-21</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-04",
        "title": "Siemens Analytics Toolkit",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Multiple Siemens applications are affected by improper certificate validation in Siemens Analytics Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens Analytics Toolkit are affected:</p>\n<ul>\n<li>Siemens Software Center vers:intdot/&lt;3.5.8.2 (CVE-2025-40745)</li>\n<li>Simcenter 3D vers:intdot/&lt;2506.6000 (CVE-2025-40745)</li>\n<li>Simcenter Femap vers:intdot/&lt;2506.0002 (CVE-2025-40745)</li>\n<li>Simcenter STAR-CCM+ vers:intdot/&lt;2602 (CVE-2025-40745)</li>\n<li>Solid Edge SE2025</li>\n<li>Solid Edge SE2026</li>\n<li>Tecnomatix Plant Simulation vers:intdot/&lt;2504.0008 (CVE-2025-40745)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 3.7</td>\n<td>Siemens</td>\n<td>Siemens Analytics Toolkit</td>\n<td>Improper Certificate Validation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40745</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40745\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Analytics Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Solid Edge SE2025, Solid Edge SE2026, Tecnomatix Plant Simulation</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V225.0 Update 13 or later version<br><a href=\"https://support.sw.siemens.com/product/246738425/\">https://support.sw.siemens.com/product/246738425/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V226.0 Update 04 or later version<br><a href=\"https://support.sw.siemens.com/product/246738425/\">https://support.sw.siemens.com/product/246738425/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2504.0008 or later version<br><a href=\"https://support.sw.siemens.com/product/297028302/\">https://support.sw.siemens.com/product/297028302/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2506.0002 or later version<br><a href=\"https://support.sw.siemens.com/product/275652363/\">https://support.sw.siemens.com/product/275652363/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2506.6000 or later version<br><a href=\"https://support.sw.siemens.com/product/289054037/\">https://support.sw.siemens.com/product/289054037/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2602 or later version<br><a href=\"https://support.sw.siemens.com/product/226870983/\">https://support.sw.siemens.com/product/226870983/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.5.8.2 or later version<br><a href=\"https://www.sw.siemens.com/en-US/siemens-software-center/\">https://www.sw.siemens.com/en-US/siemens-software-center/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/295.html\">CWE-295 Improper Certificate Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.7</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-981622 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-981622 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-07",
        "title": "Siemens SCALANCE",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SCALANCE are affected:</p>\n<ul>\n<li>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n<li>SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) vers:intdot/&lt;6.6.0 (CVE-2020-24588, CVE-2020-26139, CVE-2020-26140, CVE-2020-26141, CVE-2020-26143, CVE-2020-26144, CVE-2020-26146, CVE-2020-26147, CVE-2021-3712, CVE-2022-0778, CVE-2022-31765, CVE-2022-36323, CVE-2022-36324, CVE-2022-36325, CVE-2023-44373)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Siemens</td>\n<td>Siemens SCALANCE</td>\n<td>Missing Authentication for Critical Function, Improper Authentication, Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Improper Validation of Integrity Check Value, Improper Input Validation, Out-of-bounds Read, Loop with Unreachable Exit Condition ('Infinite Loop'), Missing Authorization, Allocation of Resources Without Limits or Throttling, Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications, Information Technology, Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-24588</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-24588\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Mitigation</strong><br>Disable A-MSDU, if possible</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.5</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26139</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26139\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/287.html\">CWE-287 Improper Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26140</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26140\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/74.html\">CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26141</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26141\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/354.html\">CWE-354 Improper Validation of Integrity Check Value</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26143</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26143\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26144</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26144\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26146</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26146\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26147</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26147\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls</p>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N\">CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-3712</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL's own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-3712\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-0778</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-0778\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/835.html\">CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-31765</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-31765\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-36323</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-36323\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/74.html\">CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-36324</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-36324\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-36325</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-36325\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/80.html\">CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-44373</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-44373\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SCALANCE</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V6.6.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996102/\">https://support.industry.siemens.com/cs/ww/en/view/109996102/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/74.html\">CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-019200 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-019200 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-05",
        "title": "Hardy Barth Salia EV Charge Controller",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution.</strong></p>\n<p>The following versions of Hardy Barth Salia EV Charge Controller are affected:</p>\n<ul>\n<li>Salia Board Firmware &lt;=2.3.81 (CVE-2025-5873, CVE-2025-10371)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.3</td>\n<td>Hardy Barth</td>\n<td>Hardy Barth Salia EV Charge Controller</td>\n<td>Unrestricted Upload of File with Dangerous Type</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-5873</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability was found in eCharge Hardy Barth Salia PLCC 2.3.81. It has been declared as critical. This vulnerability affects unknown code of the file /firmware.php of the component Web UI. The manipulation of the argument media leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-5873\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hardy Barth Salia EV Charge Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hardy Barth</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Hardy Barth Salia Board Firmware: &lt;=2.3.81</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Hardy Barth did not respond to CISA's request for coordination.</p>\n<p><strong>Mitigation</strong><br>Contact Hardy Barth using their contact page here: https://www.hardy-barth.de/de/kontakt for more information.<br><a href=\"https://www.hardy-barth.de/de/kontakt\">https://www.hardy-barth.de/de/kontakt</a></p>\n<p><strong>Mitigation</strong><br>Alternatively, Hardy Barth can also be contacted through their eCharge brand here: https://www.echarge.de/en/contact_company<br><a href=\"https://www.echarge.de/en/contact_company\">https://www.echarge.de/en/contact_company</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-10371</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security flaw has been discovered in eCharge Hardy Barth Salia PLCC 2.3.81. This issue affects some unknown processing of the file /api.php. The manipulation of the argument setrfidlist results in unrestricted upload. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-10371\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hardy Barth Salia EV Charge Controller</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hardy Barth</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Hardy Barth Salia Board Firmware: &lt;=2.3.81</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Hardy Barth did not respond to CISA's request for coordination.</p>\n<p><strong>Mitigation</strong><br>Contact Hardy Barth using their contact page here: https://www.hardy-barth.de/de/kontakt for more information.<br><a href=\"https://www.hardy-barth.de/de/kontakt\">https://www.hardy-barth.de/de/kontakt</a></p>\n<p><strong>Mitigation</strong><br>Alternatively, Hardy Barth can also be contacted through their eCharge brand here: https://www.echarge.de/en/contact_company<br><a href=\"https://www.echarge.de/en/contact_company\">https://www.echarge.de/en/contact_company</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CISA discovered a public Proof of Concept (PoC) as authored by YZS17 and reported it to Hardy Barth</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-21</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-03",
        "title": "Siemens SINEC NMS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SINEC NMS are affected:</p>\n<ul>\n<li>SINEC NMS</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.3</td>\n<td>Siemens</td>\n<td>Siemens SINEC NMS</td>\n<td>Improper Verification of Cryptographic Signature</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-24032</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. (ZDI-CAN-27564)</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24032\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC NMS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC NMS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V4.0 SP3 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000760/\">https://support.industry.siemens.com/cs/ww/en/view/110000760/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/347.html\">CWE-347 Improper Verification of Cryptographic Signature</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-801704 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-801704 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-06",
        "title": "Zero Motorcycles Firmware",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to pair via Bluetooth with a motorcycle, gaining unauthorized access to all Bluetooth functions, including changing the firmware.</strong></p>\n<p>The following versions of Zero Motorcycles Firmware are affected:</p>\n<ul>\n<li>Zero Motorcycles firmware &lt;=44 (CVE-2026-1354)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.4</td>\n<td>Zero Motorcycles</td>\n<td>Zero Motorcycles Firmware</td>\n<td>Key Exchange without Entity Authentication</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1354</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Zero Motorcycles firmware versions 44 and prior enable an attacker to forcibly pair a device with the motorcycle via Bluetooth. Once paired, an attacker can utilize over-the-air firmware updating functionality to potentially upload malicious firmware to the motorcycle. The motorcycle must first be in Bluetooth pairing mode, and the attacker must be in proximity of the vehicle and understand the full pairing process, to be able to pair their device with the vehicle. The attacker's device must remain paired with and in proximity of the motorcycle for the entire duration of the firmware update.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1354\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Zero Motorcycles Firmware</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Zero Motorcycles</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Zero Motorcycles Zero Motorcycles firmware: &lt;=44</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Zero Motorcycles has investigated this report and cautions users to pair their mobile device to their vehicle in a safe location where they can be sure no one else will try to pair at the same time. Once initiated, complete the full pairing process and confirm it is successful. Store physical keys in a secure location and do not leave the bike unattended with the key in the \"ON\" position. Zero Motorcycles plans to address this issue in a firmware update scheduled for release in May 2026. Update the firmware to the latest available version.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/322.html\">CWE-322 Key Exchange without Entity Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Persephone Karnstein of Bureau Veritas Cybersecurity North America reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-21</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-09",
        "title": "Siemens SINEC NMS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-09",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-09.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SINEC NMS before V4.0 SP3 contains an Authorization Bypass vulnerability that could allow an attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SINEC NMS are affected:</p>\n<ul>\n<li>SINEC NMS</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Siemens</td>\n<td>Siemens SINEC NMS</td>\n<td>Authorization Bypass Through User-Controlled Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-25654</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected products do not properly validate user authorization when processing password reset requests. This could allow an authenticated remote attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-25654\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC NMS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC NMS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Limit network access to trusted users and systems only</p>\n<p><strong>Vendor fix</strong><br>Update to V4.0 SP3 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000760/\">https://support.industry.siemens.com/cs/ww/en/view/110000760/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-605717 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-605717 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-11",
        "title": "Siemens Industrial Edge Management",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-11",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-11.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens Industrial Edge Management are affected:</p>\n<ul>\n<li>Industrial Edge Management Pro V1 vers:intdot/&gt;=1.7.6|&lt;1.15.17 (CVE-2026-33892)</li>\n<li>Industrial Edge Management Pro V2 vers:intdot/&gt;=2.0.0|&lt;2.1.1 (CVE-2026-33892)</li>\n<li>Industrial Edge Management Virtual vers:intdot/&gt;=2.2.0|&lt;2.8.0 (CVE-2026-33892)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.1</td>\n<td>Siemens</td>\n<td>Siemens Industrial Edge Management</td>\n<td>Authentication Bypass by Primary Weakness</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-33892</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33892\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Industrial Edge Management</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Industrial Edge Management Pro V1, Industrial Edge Management Pro V2, Industrial Edge Management Virtual</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ensure network access to affected products is limited to trusted parties only</p>\n<p><strong>Vendor fix</strong><br>Update to V1.15.17 or later version<br><a href=\"https://iehub.eu1.edge.siemens.cloud/\">https://iehub.eu1.edge.siemens.cloud/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2.1.1 or later version<br><a href=\"https://iehub.eu1.edge.siemens.cloud/\">https://iehub.eu1.edge.siemens.cloud/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2.8.0 or later version<br><a href=\"https://iehub.eu1.edge.siemens.cloud/\">https://iehub.eu1.edge.siemens.cloud/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/305.html\">CWE-305 Authentication Bypass by Primary Weakness</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-609469 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-609469 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-08",
        "title": "Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) are affected:</p>\n<ul>\n<li>RUGGEDCOM CROSSBOW Station Access Controller (SAC) vers:intdot/&lt;5.8 (CVE-2025-6965)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.7</td>\n<td>Siemens</td>\n<td>Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)</td>\n<td>Numeric Truncation Error</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-6965</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-6965\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>RUGGEDCOM CROSSBOW Station Access Controller (SAC)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V5.8 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000841/\">https://support.industry.siemens.com/cs/ww/en/view/110000841/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/197.html\">CWE-197 Numeric Truncation Error</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-225816 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-14</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-14</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-21</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-225816 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 21 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 21 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/20/cisa-adds-eight-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Eight Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/20/cisa-adds-eight-known-exploited-vulnerabilities-catalog",
        "summary": "<div class=\"OutlineElement Ltr SCXW178812853 BCX8\">\n<p>CISA has added eight new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>Known Exploited Vulnerabilities (KEV) Catalog</u></a>, based on evidence of active exploitation.&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW178812853 BCX8\">\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-27351\" target=\"_blank\"><u>CVE-2023-27351</u></a> PaperCut NG/MF Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-27199\" target=\"_blank\"><u>CVE-2024-27199</u></a> JetBrains TeamCity Relative Path Traversal Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2749\" target=\"_blank\"><u>CVE-2025-2749</u></a> Kentico Xperience Path Traversal Vulnerability</li>\n<li><a class=\"Hyperlink SCXW178812853 BCX8\" href=\"https://www.cve.org/CVERecord?id=CVE-2025-32975\" target=\"_blank\" rel=\"noreferrer noopener\"><u>CVE-2025-32975</u></a> Quest KACE Systems Management Appliance (SMA) Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-48700\" target=\"_blank\"><u>CVE-2025-48700</u></a> Synacor Zimbra Collaboration Suite (ZCS) Cross-site Scripting Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20122\" target=\"_blank\"><u>CVE-2026-20122</u></a> Cisco Catalyst SD-WAN Manager Incorrect Use of Privileged APIs Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20128\" target=\"_blank\"><u>CVE-2026-20128</u></a> Cisco Catalyst SD-WAN Manager Storing Passwords in a Recoverable Format Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20133\" target=\"_blank\"><u>CVE-2026-20133</u></a> Cisco Catalyst SD-WAN Manager Exposure of Sensitive Information to an Unauthorized Actor Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW178812853 BCX8\">\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\"><u>Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</u></a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\"><u>BOD 22-01 Fact Sheet</u></a> for more information.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW178812853 BCX8\">\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Mon, 20 Apr 26 12:00:00 +0000",
        "last_updated": "Mon, 20 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/20/supply-chain-compromise-impacts-axios-node-package-manager",
        "title": "\u200b\u200bSupply Chain Compromise Impacts Axios Node Package Manager\u200b",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/20/supply-chain-compromise-impacts-axios-node-package-manager",
        "summary": "<div class=\"OutlineElement Ltr SCXW232133708 BCX8\">\n<p>The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this alert to provide guidance in response to the software supply chain compromise of the Axios node package manager (npm).<a href=\"#note1\"><sup>1</sup></a> Axios is an HTTP client for JavaScript that developers commonly use in Node.js and browser environments.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW232133708 BCX8\">\n<p>On March 31, 2026, two npm packages for versions <code>axios@1.14.1</code> and <code>axios@0.30.4</code> of Axios npm injected the malicious dependency <code>plain-crypto-js@4.2.1</code> that downloads multi-stage payloads from cyber threat actor infrastructure, including a remote access trojan.<a href=\"#note2\"><sup>2</sup></a></p>\n<div class=\"OutlineElement Ltr SCXW205905216 BCX8\">\n<p>CISA urges organizations to implement the following recommendations to detect and remediate a potential compromise:\u202f</p>\n</div>\n<div class=\"ListContainerWrapper SCXW205905216 BCX8\">\n<ul>\n<li>Monitor and review code repositories, continuous integration/continuous delivery (CI/CD) pipelines, and developer machines that ran <code>npm install</code> or <code>npm update</code> with the compromised Axios version.\n<ul>\n<li>Search for cached versions of affected dependencies in artifact repositories and dependency management tools. Pin npm package dependency versions to known safe releases.</li>\n</ul>\n</li>\n</ul>\n<div class=\"OutlineElement Ltr SCXW94631961 BCX8\">\n<p>If compromised dependencies are identified, revert the environment to a known safe state.&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW94631961 BCX8\">\n<ul>\n<li>Downgrade to <code>axios@1.14.0</code> or <code>axios@0.30.3</code> and delete <code>node_modules/plain-crypto-js/</code>.</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW94631961 BCX8\">\n<ul>\n<li>Rotate/revoke credentials that may have been exposed on affected systems or pipelines (e.g., version control system [VCS] tokens, CI/CD secrets, cloud keys, npm tokens, and Secure Shell [SSH] keys). For ephemeral CI jobs, rotate all secrets injected into the compromised run.</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW94631961 BCX8\">\n<ul>\n<li>Monitor for unexpected child processes and anomalous network behavior, specifically during <code>npm install</code> or <code>npm update</code>.\n<ul>\n<li>Block and monitor outbound connections to <code>Sfrclak[.]com</code> domains.</li>\n<li>Conduct continuous indicator searches and endpoint detection and response (EDR) hunts to confirm no indicators of compromise (IOCs) remain; ensure no further egress to the command and control (C2).</li>\n</ul>\n</li>\n</ul>\n<div class=\"OutlineElement Ltr SCXW237985159 BCX8\">\n<p>In addition, CISA recommends organizations using Axios npm:</p>\n</div>\n<div class=\"ListContainerWrapper SCXW237985159 BCX8\">\n<ul>\n<li>Mandate phishing-resistant multifactor authentication (MFA) on all developer accounts, especially for critical platforms.</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW237985159 BCX8\">\n<ul>\n<li>Set\u202f<code>ignore-scripts=true</code> in the <code>.npmrc</code> configuration file, which prevents potentially malicious scripts from executing during npm install packages.</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW237985159 BCX8\">\n<ul>\n<li>Set <code>min-release-age=7</code> in the <code>.npmrc</code> configuration file to only install packages that have been published for at least seven days, which helps avoid installation of packages that may not be completely vetted or are potentially malicious.</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW237985159 BCX8\">\n<ul>\n<li>Establish and maintain a baseline of normal execution behavior for tools that use Axios.\n<ul>\n<li>Alert when a dependency behaves differently (e.g., building containers, enabling shells, executing commands) and trace outbound network activity for anomalous connections.</li>\n</ul>\n</li>\n</ul>\n<div class=\"SCXW13694102 BCX8\">\n<div class=\"OutlineElement Ltr SCXW13694102 BCX8\">\n<p>See the following resources for additional guidance on this compromise:&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW13694102 BCX8\">\n<ul>\n<li>GitHub: <a href=\"https://github.com/axios/axios/issues/10636\" target=\"_blank\"><u>Post Mortem: axios npm supply chain compromise #10636</u></a></li>\n</ul>\n</div>\n</div>\n<div class=\"SCXW13694102 BCX8\">\n<div class=\"ListContainerWrapper SCXW13694102 BCX8\">\n<ul>\n<li>Microsoft: <a href=\"https://www.microsoft.com/en-us/security/blog/2026/04/01/mitigating-the-axios-npm-supply-chain-compromise/\" target=\"_blank\"><u>Mitigating the Axios npm supply chain compromise</u></a></li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW13694102 BCX8\">\n<ul>\n<li>StepSecurity: <a href=\"https://www.stepsecurity.io/blog/axios-compromised-on-npm-malicious-versions-drop-remote-access-trojan\" target=\"_blank\"><u>axios Compromised on npm - Malicious Versions Drop Remote Access Trojan</u></a></li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW13694102 BCX8\">\n<ul>\n<li>npm Docs: <a href=\"https://docs.npmjs.com/packages-and-modules/securing-your-code\" target=\"_blank\"><u>Securing your code</u></a></li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW13694102 BCX8\">\n<ul>\n<li>Socket: <a href=\"https://socket.dev/blog/axios-npm-package-compromised\" target=\"_blank\"><u>Supply Chain Attack on Axios Pulls Malicious Dependency from npm</u></a></li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.</p>\n<h2><strong>Notes</strong></h2>\n<p><a class=\"ck-anchor\" id=\"note1\"></a><sup>1</sup> \u201cPost Mortem: axios npm supply chain compromise,\u201d axios GitHub, Issue #10636, March 31, 2026, <a href=\"https://github.com/axios/axios/issues/10636\" target=\"_blank\">https://github.com/axios/axios/issues/10636</a>.</p>\n<p><a class=\"ck-anchor\" id=\"note2\"></a><sup>2</sup> \u201cMitigating the Axios npm supply chain compromise,\u201d Microsoft Threat Intelligence and Microsoft Defender Security Research Team, April 1, 2026, <a href=\"https://www.microsoft.com/en-us/security/blog/2026/04/01/mitigating-the-axios-npm-supply-chain-compromise/\" target=\"_blank\">https://www.microsoft.com/en-us/security/blog/2026/04/01/mitigating-the-axios-npm-supply-chain-compromise/</a>.</p>\n</div>\n</div>\n</div>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Mon, 20 Apr 26 12:00:00 +0000",
        "last_updated": "Mon, 20 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-04",
        "title": "AVEVA Pipeline Simulation",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify simulation parameters, training configuration and training records.</strong></p>\n<p>The following versions of AVEVA Pipeline Simulation are affected:</p>\n<ul>\n<li>Pipeline Simulation &lt;=2025_SP1_build_7.1.9497.6351</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>AVEVA</td>\n<td>AVEVA Pipeline Simulation</td>\n<td>Missing Authorization</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United Kingdom</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-5387</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an unauthenticated miscreant to perform operations intended only for Simulator Instructor or Simulator Developer (Administrator) roles, resulting in privilege escalation with potential for modification of simulation parameters, training configuration, and training records.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-5387\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Pipeline Simulation</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Pipeline Simulation: &lt;=2025_SP1_build_7.1.9497.6351</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>All affected versions can be fixed by upgrading to AVEVA Pipeline Simulation 2025 SP1 P01 (build 7.1.9580.8513) or higher. (https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f)<br><a href=\"https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f\">https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f</a></p>\n<p><strong>Mitigation</strong><br>For more information, please see AVEVA's security bulletin AVEVA-2026-004 (https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf).<br><a href=\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf\">https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf</a></p>\n<p><strong>Vendor fix</strong><br>Restrict Network Access: Implement host-based and/or network firewall controls on all nodes hosting the Pipeline Simulation Server API to ensure that only trusted Pipeline Simulation client systems are permitted to establish connections.</p>\n<p><strong>Mitigation</strong><br>Enforce Secure Communication: Enable TLS for all API communications and ensure that server certificates are properly managed and protected to reduce the risk of manipulator-in-the-middle(MitM) attacks and tampering with data in transit.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>AVEVA reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-16</td>\n<td>1</td>\n<td>Initial Republication of AVEVA-2026-004</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 16 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 16 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-01",
        "title": "Delta Electronics ASDA-Soft",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code.</strong></p>\n<p>The following versions of Delta Electronics ASDA-Soft are affected:</p>\n<ul>\n<li>ASDA-Soft &lt;=V7.2.2.0</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Delta Electronics</td>\n<td>Delta Electronics ASDA-Soft</td>\n<td>Stack-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-5726</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A stack-based buffer overflow vulnerability is triggered in ASDA-Soft version 7.2.0.0 during the parsing of malformed .par files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-5726\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics ASDA-Soft</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics ASDA-Soft: &lt;=V7.2.2.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Delta Electronics recommends users download and upgrade ASDA-Soft to v7.2.6.0 or later. If you have any product-related support concerns, contact Delta via the portal page at https://www.deltaww.com/en-US/service-support/contact-us?type=1 for any information or materials you may require.<br><a href=\"https://www.deltaww.com/en-US/service-support/contact-us?type=1\">https://www.deltaww.com/en-US/service-support/contact-us?type=1</a></p>\n<p><strong>Mitigation</strong><br>Delta Electronics provides the following general recommendations: Do not click on untrusted internet links or open unsolicited attachments in emails. Avoid exposing control systems and equipment to the Internet. Place control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use a secure access method, such as a virtual private network (VPN).</p>\n<p><strong>Mitigation</strong><br>For more information, see Delta Electronics advisory Delta-PCSA-2026-00007 athttps://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf<br><a href=\"https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf\">https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Feng Xiong of TrendAI Zero Day Initiative reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-16</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 16 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 16 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-02",
        "title": "Horner Automation Cscape and XL4, XL7 PLC",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services.</strong></p>\n<p>The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected:</p>\n<ul>\n<li>Cscape v10.0</li>\n<li>XL7 PLC v15.60</li>\n<li>XL4 PLC v16.32.0</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>Horner Automation</td>\n<td>Horner Automation Cscape and XL4, XL7 PLC</td>\n<td>Weak Password Requirements</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-6284</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker with network access to the PLC is able to brute force discover passwords to gain unauthorized access to systems and services. The limited password complexity and no password input limiters makes brute force password enumeration possible.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-6284\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Horner Automation Cscape and XL4, XL7 PLC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Horner Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Horner Automation Cscape: v10.0, Horner Automation XL7 PLC: v15.60, Horner Automation XL4 PLC: v16.32.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Horner Automation recommends users update to Cscape v10.2 SP2 or later. Horner Automation has also released the latest firmware for both XL4 and XL7 PLCs. Horner recommends users update to the latest version of the firmware. https://hornerautomation.com/cscape-software-free/cscape-software/.<br><a href=\"https://hornerautomation.com/cscape-software-free/cscape-software/\">https://hornerautomation.com/cscape-software-free/cscape-software/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Horner Automation's release notes.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/521.html\">CWE-521 Weak Password Requirements</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous researcher reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-16</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 16 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 16 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03",
        "title": "Anviz Multiple Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow attackers to conduct reconnaissance, capture or decrypt sensitive data, alter device configurations, gain unauthorized administrative or root\u2011level access, execute arbitrary code, compromise credentials or communications, and ultimately obtain full control over affected devices.</strong></p>\n<p>The following versions of Anviz Multiple Products are affected:</p>\n<ul>\n<li>CX2 Lite Firmware vers:all/* (CVE-2026-32648, CVE-2026-40461, CVE-2026-35682, CVE-2026-35546, CVE-2026-40066, CVE-2026-33569)</li>\n<li>CX7 Firmware vers:all/* (CVE-2026-33093, CVE-2026-35061, CVE-2026-32648, CVE-2026-40461, CVE-2026-35546, CVE-2026-40066, CVE-2026-32324, CVE-2026-31927, CVE-2026-33569)</li>\n<li>CrossChex Standard vers:all/* (CVE-2026-40434, CVE-2026-32650)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Anviz</td>\n<td>Anviz Multiple Products</td>\n<td>Missing Authorization, Missing Authentication for Critical Function, Improper Neutralization of Special Elements used in a Command ('Command Injection'), Download of Code Without Integrity Check, Use of Hard-coded Cryptographic Key, Relative Path Traversal, Cleartext Transmission of Sensitive Information, Improper Verification of Source of a Communication Channel, Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Defense Industrial Base, Energy, Financial Services, Food and Agriculture, Government Services and Facilities, Healthcare and Public Health, Information Technology, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-33093</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX7 is vulnerable to an unauthenticated POST to the device that captures a photo with the front facing camera, exposing visual information about the deployment environment.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33093\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35061</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX7 is vulnerable to the most recently captured test photo that can be retrieved without authentication, revealing sensitive operational imagery.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35061\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32648</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite and CX7 are vulnerable to unauthenticated access that discloses debug configuration details (e.g., SSH/RTTY status), assisting attackers in reconnaissance against the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32648\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40461</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite and CX7 are vulnerable to unauthenticated POST requests that modify debug settings (e.g., enabling SSH), allowing unauthorized state changes that can facilitate later compromise.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40461\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35682</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite is vulnerable to an authenticated command injection via a filename parameter that enables arbitrary command execution (e.g., starting telnetd), resulting in root\u2011level access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35682\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/77.html\">CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35546</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite and CX7 are vulnerable to unauthenticated firmware uploads. This causes crafted archives to be accepted, enabling attackers to plant and execute code and obtain a reverse shell.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35546\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40066</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite and CX7 are vulnerable to unverified update packages that can be uploaded. The device unpacks and executes a script resulting in unauthenticated remote code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40066\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/494.html\">CWE-494 Download of Code Without Integrity Check</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32324</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX7 is vulnerable because the application embeds reusable certificate/key material, enabling decryption of MQTT traffic and potential interaction with device messaging channels at scale.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32324\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31927</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX7 is vulnerable to an authenticated CSV upload which allows path traversal to overwrite arbitrary files (e.g., /etc/shadow), enabling unauthorized SSH access when combined with debug\u2011setting changes.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31927\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/23.html\">CWE-23 Relative Path Traversal</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-33569</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CX2 Lite and CX7 administrative sessions occur over HTTP, enabling on\u2011path attackers to sniff credentials and session data, which can be used to compromise the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33569\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40434</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CrossChex Standard lacks source verification in the client/server channel, enabling TCP packet injection by an attacker on the same network to alter or disrupt application traffic.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40434\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CrossChex Standard: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/940.html\">CWE-940 Improper Verification of Source of a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-32650</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CrossChex Standard is vulnerable when an attacker manipulates the TDS7 PreLogin to disable encryption, causing database credentials to be sent in plaintext and enabling unauthorized database access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32650\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Anviz Multiple Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Anviz</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Anviz CrossChex Standard: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html.<br><a href=\"https://www.anviz.com/contact-us.html\">https://www.anviz.com/contact-us.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/757.html\">CWE-757 Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous researcher reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-16</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 16 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 16 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34197\" target=\"_blank\">CVE-2026-34197</a> Apache ActiveMQ Improper Input Validation Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 16 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 16 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/14/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/14/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2009-0238\" target=\"_blank\">CVE-2009-0238</a> Microsoft Office Remote Code Execution Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-32201\" target=\"_blank\">CVE-2026-32201</a> Microsoft SharePoint Server Improper Input Validation Vulnerability&nbsp;</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet </a>for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 14 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 14 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/13/cisa-adds-seven-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Seven Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/13/cisa-adds-seven-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added seven new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2012-1854\" target=\"_blank\">CVE-2012-1854</a> Microsoft Visual Basic for Applications Insecure Library Loading Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-9715\" target=\"_blank\">CVE-2020-9715</a> Adobe Acrobat Use-After-Free Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-21529\" target=\"_blank\">CVE-2023-21529</a> Microsoft Exchange Server Deserialization of Untrusted Data Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-36424\" target=\"_blank\">CVE-2023-36424</a> Microsoft Windows Out-of-Bounds Read Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-60710\" target=\"_blank\">CVE-2025-60710</a> Microsoft Windows Link Following Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-21643\" target=\"_blank\">CVE-2026-21643</a> Fortinet SQL Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34621\" target=\"_blank\">CVE-2026-34621</a> Adobe Acrobat and Reader Prototype Pollution Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 13 Apr 26 12:00:00 +0000",
        "last_updated": "Mon, 13 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-099-01",
        "title": "Contemporary Controls BASC 20T",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-099-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-099-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to enumerate the functionality of each component associated with the PLC, reconfigure, rename, delete, perform file transfers, and make remote procedure calls.</strong></p>\n<p>The following versions of Contemporary Controls BASC 20T are affected:</p>\n<ul>\n<li>BASControl20 3.1 (CVE-2025-13926)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Contemporary Controls Sedona Alliance</td>\n<td>Contemporary Controls BASC 20T</td>\n<td>Reliance on Untrusted Inputs in a Security Decision</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13926</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker could use data obtained by sniffing the network traffic to forge packets in order to make arbitrary requests to Contemporary Controls BASC 20T.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13926\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Contemporary Controls BASC 20T</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Contemporary Controls Sedona Alliance</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Contemporary Controls Sedona Alliance BASControl20: 3.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>According to Contemporary Controls, the BASC-20T is an obsolete product. It is recommended that users of the affected product contact Contemporary Controls for additional information.<br><a href=\"https://www.ccontrols.com/support/contacttech.htm\">https://www.ccontrols.com/support/contacttech.htm</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/807.html\">CWE-807 Reliance on Untrusted Inputs in a Security Decision</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Joseph Fields of Naval Information Warfare Center Pacific reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-09</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 09 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 09 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-099-02",
        "title": "GPL Odorizers GPL750",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-099-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-099-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a low privileged remote attacker to manipulate register values, which would result in too much or too little odorant being injected into a gas line.</strong></p>\n<p>The following versions of GPL Odorizers GPL750 are affected:</p>\n<ul>\n<li>GPL750 (XL4) &gt;=v1.0|</li>\n<li>GPL750 (XL4 Prime) &gt;=v4.0|</li>\n<li>GPL750 (XL7) &gt;=v13.0|</li>\n<li>GPL750 (XL7 Prime) &gt;=v18.4|</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.6</td>\n<td>GPL Odorizers</td>\n<td>GPL Odorizers GPL750</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-4436</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A low-privileged remote attacker can send Modbus packets to manipulate register values that are inputs to the odorant injection logic such that too much or too little odorant is injected into a gas line.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-4436\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>GPL Odorizers GPL750</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>GPL Odorizers</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>GPL Odorizers GPL750 (XL4): &gt;=v1.0|&lt;v6.0, GPL Odorizers GPL750 (XL4 Prime): &gt;=v4.0|&lt;v6.0, GPL Odorizers GPL750 (XL7): &gt;=v13.0|&lt;v20.0, GPL Odorizers GPL750 (XL7 Prime): &gt;=v18.4|&lt;v20.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>GPL Odorizers recommends users update to the latest software version of the GPL750 in connection with the latest firmware from Horner Automation for the XL4, XL4 Prime, XL7, and XL7 Prime devices.https://lincenergysystems-my.sharepoint.com/:f:/p/h_baer/IgDYaHIhXpyLQJvnKPd6b80TAUgV7Lp8qmVYBFUb0lmr7ak?e=JLeADm.<br><a href=\"https://lincenergysystems-my.sharepoint.com/:f:/p/h_baer/IgDYaHIhXpyLQJvnKPd6b80TAUgV7Lp8qmVYBFUb0lmr7ak?e=JLeADm\">https://lincenergysystems-my.sharepoint.com/:f:/p/h_baer/IgDYaHIhXpyLQJvnKPd6b80TAUgV7Lp8qmVYBFUb0lmr7ak?e=JLeADm</a></p>\n<p><strong>Mitigation</strong><br>GPL Odorizers recommends users clear the old files from their microSD cards, keeping only the LOGS folder and the FIRMWARE.LIC file if they have a WebMI license. The compressed folder downloaded from the link above can then be extracted to the root directory of the microSD card. These files already include the corresponding firmware update. If users do not have IT permissions to access their microSD cards, GPL Odorizers can provide preconfigured SD cards that technicians can simply swap into their odorizers prior to installation.</p>\n<p><strong>Mitigation</strong><br>For assistance in updating GPL Odorizers to the latest version, users should reach out to GPL Odorizers directly via phone number (303) 697-6701 during the hours of 8:00 a.m. to 4:00 p.m. MST.</p>\n<p><strong>Mitigation</strong><br>Horner Automation offers firmware version 15.76 for their XL Series and version 17.30 for their XL Prime Series controllers https://hornerautomation.com/controller-firmware/. An installation guide is available for both the XL series and the XL Prime series.<br><a href=\"https://hornerautomation.com/controller-firmware/\">https://hornerautomation.com/controller-firmware/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous researcher reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-09</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 09 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 09 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/08/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/08/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1340\" target=\"_blank\">CVE-2026-1340</a> Ivanti Endpoint Manager Mobile (EPMM) Code Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 08 Apr 26 12:00:00 +0000",
        "last_updated": "Wed, 08 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-097-01",
        "title": "Mitsubishi Electric GENESIS64 and ICONICS Suite products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-097-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-097-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow a local attacker to disclose SQL Server credentials used by the affected products and use them to disclose, tamper with, or destroy data, or to cause a denial-of-service (DoS) condition on the system.</strong></p>\n<p>The following versions of Mitsubishi Electric GENESIS64 and ICONICS Suite products are affected:</p>\n<ul>\n<li>GENESIS64 &lt;=10.97.3 (CVE-2025-14815, CVE-2025-14816)</li>\n<li>ICONICS Suite &lt;=10.97.3 (CVE-2025-14815, CVE-2025-14816)</li>\n<li>MobileHMI &lt;=10.97.3 (CVE-2025-14815, CVE-2025-14816)</li>\n<li>Hyper Historian &lt;=10.97.3 (CVE-2025-14815, CVE-2025-14816)</li>\n<li>AnalytiX &lt;=10.97.3 (CVE-2025-14815, CVE-2025-14816)</li>\n<li>MC Works 64 vers:all/* (CVE-2025-14815, CVE-2025-14816)</li>\n<li>GENESIS &lt;=11.02 (CVE-2025-14815, CVE-2025-14816)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric GENESIS64 and ICONICS Suite products</td>\n<td>Cleartext Storage of Sensitive Information, Cleartext Storage of Sensitive Information in GUI</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan, United States<strong>&nbsp;</strong></li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14815</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When the local caching feature using SQLite is enabled and SQL authentication is used for the SQL Server authentication, the SQL Server credentials are stored in plaintext within the local SQLite file. This results in a vulnerability due to Cleartext Storage of Sensitive Information (CWE 312), which may lead to information disclosure, tampering, or denial of service (DoS).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-14815\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric GENESIS64 and ICONICS Suite products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric GENESIS64: &lt;=10.97.3, Mitsubishi Electric ICONICS Suite: &lt;=10.97.3, Mitsubishi Electric MobileHMI: &lt;=10.97.3, Mitsubishi Electric Hyper Historian: &lt;=10.97.3, Mitsubishi Electric AnalytiX: &lt;=10.97.3, Mitsubishi Electric MC Works 64: vers:all/*, Mitsubishi Electric GENESIS: &lt;=11.02, Mitsubishi Electric Iconics Digital Solutions GENESIS64: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions MobileHMI: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions Hyper Historian: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions AnalytiX: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS: &lt;=11.02</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian and AnalytiX. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. After installation, perform the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\Cache\\*.sdf\". For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian and AnalytiX. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. After installation, perform the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\Cache\\*.sdf\". For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at \"https://iconics.com/about/security/cert\".<br><a href=\"https://iconics.com/about/security/cert\">https://iconics.com/about/security/cert</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 11.03 or later for GENESIS. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. After installation, perform the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\11\\Cache\\*.sqlite3\". For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 11.03 or later for GENESIS. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. After installation, perform the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\11\\Cache\\*.sqlite3\". For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at \"https://iconics.com/about/security/cert\".<br><a href=\"https://iconics.com/about/security/cert\">https://iconics.com/about/security/cert</a></p>\n<p><strong>No fix planned</strong><br>There are no plans to release fixed version for MC Works64. For users of MC Works64, refer to the Mitsubishi Electric security advisory \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\", and take the actions described there.<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Mitigation</strong><br>For customer of GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend performing the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\Cache\\*.sdf\".</p>\n<p><strong>Mitigation</strong><br>For customer of GENESIS that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend performing the following step (1) and (2). (1) In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\11\\Cache\\*.sqlite3\".</p>\n<p><strong>Mitigation</strong><br>For customer of MC Works 64, Mitsubishi Electric recommends performing the following step (1) and (2). (1)In Workbench, open the \u201cConfigure Application(s) Settings\u201d dialog. In the \u201cAvailable Applications\u201d list, uncheck the \u201cLocal Cache\u201d column for applications. (2) Delete the files created by the local cache functionality from \"C:\\ProgramData\\ICONICS\\Cache\\*.sdf\".</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend using Windows authentication instead of SQL authentication for the SQL server authentication method, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend configuring the PCs with the affected product installed so that only an administrator can log in, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend using the PCs with the affected product installed in the LAN and blocking remote login from untrusted networks and hosts, and from non-administrator users, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed and to the network to which the PC is connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14816</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Hyper Historian Splitter feature of the affected products, when SQL authentication is used for the SQL Server authentication, the SQL Server credentials are displayed in plain text in the GUI. This results in a vulnerability due to Cleartext Storage of Sensitive Information in GUI (CWE\u2011317 ), which may lead to information disclosure, tampering, or denial\u2011of\u2011service (DoS).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-14816\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric GENESIS64 and ICONICS Suite products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric GENESIS64: &lt;=10.97.3, Mitsubishi Electric ICONICS Suite: &lt;=10.97.3, Mitsubishi Electric MobileHMI: &lt;=10.97.3, Mitsubishi Electric Hyper Historian: &lt;=10.97.3, Mitsubishi Electric AnalytiX: &lt;=10.97.3, Mitsubishi Electric MC Works 64: vers:all/*, Mitsubishi Electric GENESIS: &lt;=11.02, Mitsubishi Electric Iconics Digital Solutions GENESIS64: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions MobileHMI: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions Hyper Historian: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions AnalytiX: &lt;=10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS: &lt;=11.02</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian and AnalytiX. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian and AnalytiX. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at \"https://iconics.com/about/security/cert\".<br><a href=\"https://iconics.com/about/security/cert\">https://iconics.com/about/security/cert</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 11.03 or later for GENESIS. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 11.03 or later for GENESIS. Please download the fixed version from the link \"https://iconicsinc.my.site.com/community/s/resource-center/product-downloads\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at \"https://iconics.com/about/security/cert\".<br><a href=\"https://iconics.com/about/security/cert\">https://iconics.com/about/security/cert</a></p>\n<p><strong>No fix planned</strong><br>There are no plans to release fixed version for MC Works64. For users of MC Works64, refer to the Mitsubishi Electric security advisory \"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\", and take the actions described there.<br><a href=\"https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf\">https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2025-023.pdf</a></p>\n<p><strong>Mitigation</strong><br>For customer of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend performing the following steps (1) and (2). (1) Change the permissions of HHSplitter.exe so that only trusted administrators can execute it. (2) Delete HHSplitter.exe from the system if it is unnecessary.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend using Windows authentication instead of SQL authentication for the SQL server authentication method, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend configuring the PCs with the affected product installed so that only an administrator can log in, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend using the PCs with the affected product installed in the LAN and blocking remote login from untrusted networks and hosts, and from non-administrator users, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when internet access is required, and from non-administrator users, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed and the network to which the PC is connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/317.html\">CWE-317 Cleartext Storage of Sensitive Information in GUI</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric V20251021-001, V20251029-001 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-07</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-07</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-04-07</td>\n<td>2</td>\n<td>Initial CISA Republication of CISA V20251021-001, V20251029-001 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 07 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 07 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/cybersecurity-advisories/aa26-097a",
        "title": "Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across US Critical Infrastructure",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/cybersecurity-advisories/aa26-097a",
        "summary": "<h2><strong>Advisory at a Glance</strong></h2>\n<table>\n<tbody>\n<tr>\n<th>Title</th>\n<td>Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across US Critical Infrastructure</td>\n</tr>\n<tr>\n<th>Original Publication</th>\n<td>April 7, 2026</td>\n</tr>\n<tr>\n<th>Executive Summary</th>\n<td>\n<p>Iran-affiliated advanced persistent threat (APT) actors are conducting exploitation activity targeting internet-facing operational technology (OT) devices, including programmable logic controllers (PLCs) manufactured by Rockwell Automation/Allen-Bradley. This activity has led to PLC disruptions across several U.S. critical infrastructure sectors through malicious interactions with the project file and manipulation of data on human machine interface (HMI) and supervisory control and data acquisition (SCADA) displays, resulting in operational disruption and financial loss.&nbsp;</p>\n<p>U.S. organizations should urgently review the tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) in this advisory for indications of current or historical activity on their networks, and apply the recommendations listed in the <a href=\"#Mitigations\"><strong>Mitigations</strong></a><strong> </strong>section of this advisory to reduce the risk of compromise.</p>\n</td>\n</tr>\n<tr>\n<th>Affected Products</th>\n<td>\n<ul>\n<li>Rockwell Automation/Allen-Bradley manufactured PLCs</li>\n<li>Potentially other branded PLCs</li>\n</ul>\n</td>\n</tr>\n<tr>\n<th>Key Actions</th>\n<td>\n<ul>\n<li>Remove PLCs from direct internet exposure via secure gateway and firewall.</li>\n<li>Query available logs for the provided IOCs in the corresponding time frames.</li>\n<li>Check available logs for suspicious traffic on the ports associated with OT devices, including <code>44818</code>, <code>2222</code>, <code>102</code>, and <code>502</code>, especially traffic originating from overseas hosting providers.</li>\n<li>For Rockwell Automation devices, place the physical mode switch on the controller into run position.&nbsp;Contact the authoring agencies and Rockwell Automation for guidance if you believe your organization was targeted.</li>\n</ul>\n</td>\n</tr>\n<tr>\n<th>Indicators of Compromise</th>\n<td>\n<p>For a downloadable copy of IOCs, see:</p>\n<ul>\n<li><a href=\"https://www.cisa.gov/sites/default/files/2026-04/AA26-097A.stix_.xml\">AA26-097A STIX XML</a> (35KB)</li>\n<li><a href=\"https://www.cisa.gov/sites/default/files/2026-04/AA26-097A.stix_.json\">AA26-097A STIX JSON</a> (12 KB)<br>&nbsp;</li>\n</ul>\n</td>\n</tr>\n<tr>\n<th>Intended Audience</th>\n<td>\n<p><strong>Organizations:</strong> Critical Infrastructure</p>\n<p><strong>Sectors: </strong><a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/government-services-facilities-sector\" title=\"Government Services and Facilities\">Government Services and Facilities</a>, <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/water-and-wastewater-sector\" title=\"Water and Wastewater Systems\">Water and Wastewater Systems</a> (WWS), and <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/energy-sector\" title=\"Energy\">Energy</a>&nbsp;</p>\n<p><strong>Roles:</strong> <a href=\"https://niccs.cisa.gov/tools/nice-framework/work-role/defensive-cybersecurity\" target=\"_blank\" title=\"Defensive cybersecurity analysts\">Defensive cybersecurity analysts</a>, <a href=\"https://niccs.cisa.gov/tools/nice-framework/work-role/operational-technology-ot-cybersecurity-engineering\" target=\"_blank\" title=\"OT cybersecurity engineers\">OT cybersecurity engineers</a>, <a href=\"https://niccs.cisa.gov/tools/nice-framework/work-role/cybersecurity-architecture\" target=\"_blank\" title=\"cybersecurity architects\">cybersecurity architects</a>, <a href=\"https://niccs.cisa.gov/tools/nice-framework/work-role/secure-systems-development\" target=\"_blank\" title=\"secure systems developer\">secure systems developer</a></p>\n</td>\n</tr>\n</tbody>\n</table>\n<h2><strong>Introduction</strong></h2>\n<p>The Federal Bureau of Investigation (FBI), Cybersecurity and Infrastructure Security Agency (CISA), National Security Agency (NSA), Environmental Protection Agency (EPA), Department of Energy (DOE), and United States Cyber Command \u2013 Cyber National Mission Force (CNMF), hereafter referred to as the \u201cauthoring agencies,\u201d are urgently warning U.S. organizations of ongoing cyber exploitation of internet-connected operational technology (OT) devices, including Rockwell Automation/Allen-Bradley-manufactured programmable logic controllers (PLCs), across multiple U.S. critical infrastructure sectors. As a result of this activity, organizations from multiple U.S. critical infrastructure sectors experienced disruptions through malicious interactions with the project files<a href=\"#Note1\"><sup>1</sup></a> and the manipulation of data displayed on human machine interface (HMI) and supervisory control and data acquisition (SCADA) displays. In a few cases, this activity has resulted in operational disruption and financial loss.&nbsp;</p>\n<p>Due to the widespread use of these PLCs and the potential for additional targeting of other branded OT devices across critical infrastructure, the authoring agencies recommend U.S. organizations urgently review the tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) in this advisory for indications of current or historical activity on their networks, and apply the recommendations listed in the <a href=\"#Mitigations\"><strong>Mitigations</strong></a> section to reduce the risk of compromise.</p>\n<p>The authoring agencies assess a group of Iranian-affiliated advanced persistent threat (APT) actors is conducting this activity to cause disruptive effects within the United States. The group has targeted devices spanning multiple U.S. critical infrastructure sectors, including <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/government-services-facilities-sector\" title=\"Government Services and Facilities\">Government Services and Facilities</a> (to include local municipalities), <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/water-and-wastewater-sector\" title=\"Water and Wastewater Systems\">Water and Wastewater Systems</a> (WWS), and <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/energy-sector\" title=\"Energy\">Energy</a> Sectors. The authoring agencies previously reported on similar activity targeting PLCs by <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-335a\" title=\"CyberAv3ngers\">CyberAv3ngers</a> (aka Shahid Kaveh Group)\u2014a cyber threat actor affiliated with Iran\u2019s Islamic Revolutionary Guard Corps (IRGC) Cyber Electronic Command (CEC).&nbsp;</p>\n<p>If owners and operators discover an affected internet-accessible device in their environment, additional technical measures may be necessary to evaluate the risk of compromise. Please contact the authoring agencies and applicable vendors through existing support channels available to customers and integrators (see <a href=\"#Contact\"><strong>Contact Information</strong></a>) to receive support, mitigation, and investigation assistance, and engage your cyber incident response plans.</p>\n<p>In addition to contacting the authoring agencies, organizations with Rockwell Automation/Allen-Bradley-manufactured PLCs should review the manufacturer\u2019s previously issued guidance to strengthen the security of their operational technology deployments: <a href=\"https://www.rockwellautomation.com/en-fi/trust-center/security-advisories/advisory.PN1550.html\" target=\"_blank\" title=\"PN1550 | CVE-2021-22681: Authentication Bypass Vulnerability Found in Logix Controllers\">PN1550 | CVE-2021-22681: Authentication Bypass Vulnerability Found in Logix Controllers</a>, published in 2021, and <a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1771.html\" target=\"_blank\" title=\"Rockwell Automation Reiterates Customer Guidance to Disconnect Devices from the Internet and Harden PLCs to Protect from Cyber Threats\">SD1771 | Rockwell Automation Reiterates Customer Guidance to Disconnect Devices from the Internet and Harden PLCs to Protect from Cyber Threats</a>, published in 2026. Contact the Rockwell Automation Product Security Incident Response Team (PSIRT) at <a href=\"mailto:PSIRT@rockwellautomation.com\" title=\"PSIRT@rockwellautomation.com\">PSIRT@rockwellautomation.com</a> for questions regarding this guidance, or to report cyber incidents related to Rockwell Automation products.</p>\n<p>For more information on Iranian malicious cyber activity, see CISA\u2019s <a href=\"https://www.cisa.gov/topics/cyber-threats-and-advisories/advanced-persistent-threats/iran\" title=\"Iran Cyber Threat Overview and Advisories\">Iran Threat Overview and Advisories</a> webpage and the FBI\u2019s <a href=\"https://www.fbi.gov/investigate/counterintelligence/the-iran-threat\" target=\"_blank\" title=\"Iran Threat\">Iran Threat</a> webpage.</p>\n<p>Download the PDF version of this report:</p>\n\n\n\n\n\n<div class=\"c-file\">\n    <div class=\"c-file__download\">\n    <a href=\"https://www.cisa.gov/sites/default/files/2026-04/AA26-097A-Iranian-Affiliated-Cyber-Actors-Exploit-Programmable-Logic-Controllers-Across-US-Critical-Infrastructure_508c.pdf\" class=\"c-file__link\" target=\"_blank\">Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across US Critical Infrastructure</a>\n    <span class=\"c-file__size\">(PDF,       816.90 KB\n  )</span>\n  </div>\n</div>\n<p><strong>For a downloadable copy of IOCs, see:</strong></p>\n\n\n\n\n\n<div class=\"c-file\">\n    <div class=\"c-file__download\">\n    <a href=\"https://www.cisa.gov/sites/default/files/2026-04/AA26-097A.stix_.xml\" class=\"c-file__link\" target=\"_blank\">AA26-097A.stix_.xml</a>\n    <span class=\"c-file__size\">(XML,       35.97 KB\n  )</span>\n  </div>\n</div>\n\n\n\n\n\n<div class=\"c-file\">\n    <div class=\"c-file__download\">\n    <a href=\"https://www.cisa.gov/sites/default/files/2026-04/AA26-097A.stix_.json\" class=\"c-file__link\" target=\"_blank\">AA26-097A.stix_.json</a>\n    <span class=\"c-file__size\">(JSON,       11.87 KB\n  )</span>\n  </div>\n</div>\n<h2><strong>Background Information</strong></h2>\n<h3><strong>Similar Historical Activity Targeting Programmable Logic Controllers</strong></h3>\n<p>During a similar campaign beginning in November 2023, the IRGC CEC-affiliated cyber threat actors known as \"CyberAv3ngers\u201d targeted U.S.-based PLCs and HMIs, causing disruptive effects. Private industry and open sources also refer to this group as Hydro Kitten, Storm-0784, APT Iran, Bauxite, Mr. Soul, Soldiers of Solomon, UNC5691,&nbsp;and the Shahid Kaveh Group. These attacks compromised at least 75 devices, targeting U.S.-based Unitronics PLC devices with an HMI used across multiple critical infrastructure sectors, including WWS. For more information on this group\u2019s activity, see the authoring agencies\u2019 Joint Cybersecurity Advisory <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-335a\" title=\"IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities\">IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities</a>.</p>\n<h3><strong>Ongoing Threat Actor Activity Against U.S.-Based Programmable Logic Controllers</strong></h3>\n<p>The FBI assesses a group of Iranian-affiliated APT actors are targeting internet-exposed PLCs with the intent to cause disruptions\u2014including maliciously interacting with project files, and manipulating data displayed on HMI and SCADA displays\u2014to U.S. critical infrastructure organizations. Iranian-affiliated APT targeting campaigns against U.S. organizations have recently escalated, likely in response to hostilities between Iran, and the United States and Israel.&nbsp;</p>\n<p>Since at least March 2026, the authoring agencies identified (through engagements with victim organizations) an Iranian-affiliated APT-group that disrupted the function of PLCs. These PLCs were deployed across multiple U.S. critical infrastructure sectors (including <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/government-services-facilities-sector\" title=\"Government Services and Facilities\">Government Services and Facilities</a>, <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/water-and-wastewater-sector\" title=\"Water and Wastewater Systems\">WWS</a>, and <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/energy-sector\" title=\"Energy\">Energy</a> sectors) within a wide variety of industrial automation processes. Some of the victims experienced operational disruption and financial loss.</p>\n<h2><strong>Technical Details</strong></h2>\n<p><strong>Note:</strong> This advisory uses the <a href=\"https://attack.mitre.org/versions/v18/matrices/enterprise/\" target=\"_blank\" title=\"MITRE ATTACK Matrix for Enterprise\">MITRE ATT&amp;CK<sup>\u00ae</sup> Matrix for Enterprise</a> framework, version 18.&nbsp;See the <a href=\"#MITRE\"><strong>MITRE ATT&amp;CK Tactics and Techniques</strong></a> section of this advisory for tables of the threat actors\u2019 activity mapped to MITRE ATT&amp;CK tactics and techniques.</p>\n<h3><strong>Initial Access</strong></h3>\n<p>The authoring agencies observed Iranian-affiliated APT actors using several overseas-based IP addresses to access internet-facing Rockwell Automation/Allen-Bradley-manufactured PLCs [<a href=\"https://attack.mitre.org/techniques/T0883/\" target=\"_blank\" title=\"T0883\">T0883</a>]. The actors used leased, third-party hosted infrastructure with configuration software, such as Rockwell Automation\u2019s Studio 5000 Logix Designer software, to create an accepted connection to the victim\u2019s PLC. Targeted devices include CompactLogix and Micro850 PLC devices.&nbsp;</p>\n<h3><strong>Command and Control</strong></h3>\n<p>Inbound malicious traffic may be directed to devices on any of following ports:&nbsp;<code>44818</code>,&nbsp;<code>2222</code>,&nbsp;<code>102</code>,&nbsp;<code>22</code>, or&nbsp;<code>502</code>. The targeting of ports [<a href=\"https://attack.mitre.org/techniques/T0885/\" target=\"_blank\" title=\"T0885\">T0885</a>] associated with other OT vendors\u2019 protocols suggests these actors may also be targeting devices manufactured by companies other than Rockwell Automation/Allen-Bradley, including the Siemens&nbsp;S7 PLC. Additionally, the actors deployed Dropbear Secure Shell (SSH) software on victim endpoints to enable them to gain remote access through port&nbsp;<code>22</code> [<a href=\"https://attack.mitre.org/versions/v18/techniques/T1219/\" target=\"_blank\" title=\"T1219\">T1219</a>].</p>\n<h3><strong>Impact</strong></h3>\n<p>The FBI identified that this activity resulted in the extraction of the device\u2019s project file and data manipulation on HMI and SCADA displays [<a href=\"https://attack.mitre.org/techniques/T1565/\" target=\"_blank\" title=\"T1565\">T1565</a>].</p>\n<h2><strong>Indicators of Compromise</strong></h2>\n<p>See <a href=\"#Table1\"><strong>Table 1</strong></a> for recent IP addresses used by the Iranian-affiliated APT actors to communicate with Rockwell Automation/Allen-Bradley-manufactured devices (and potentially other branded OT devices) in the United States.</p>\n<p><strong>Disclaimer:</strong> The FBI observed that the threat actors used the IP addresses listed below in the specified time frames. This data is being provided for customers to query against logs for indications of historical targeting by the Iranian-affiliated APT actors. The authoring agencies recommend organizations investigate or vet these IP addresses prior to taking action, such as blocking.</p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><a class=\"ck-anchor\" id=\"Table1\"></a>Table 1. Indicators of Compromise</caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Indicator</th>\n<th role=\"columnheader\">Beginning of Actor Association</th>\n<th role=\"columnheader\">End of Actor Association</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>135.136.1[.]133</td>\n<td>March 2026</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]162</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]164</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]165</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]167</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]168</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]170</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n<tr>\n<td>185.82.73[.]171</td>\n<td>January 2025</td>\n<td>March 2026</td>\n</tr>\n</tbody>\n</table>\n<h2><a class=\"ck-anchor\" id=\"MITRE\"></a><a class=\"ck-anchor\" id=\"MITRE\"><strong>MITRE ATT&amp;CK Tactics and Techniques</strong></a></h2>\n<p>See <a href=\"#Table2\"><strong>Table 2</strong></a> to <a href=\"#Table4\"><strong>Table 4</strong></a><strong> </strong>for all referenced threat actor tactics and techniques in this advisory. The authoring agencies recommend organizations review historical TTPs for similar Iranian-affiliated cyber actor activity in <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-335a\" title=\"IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities\">IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities</a>. For assistance with mapping malicious cyber activity to the MITRE ATT&amp;CK framework, see CISA and MITRE ATT&amp;CK\u2019s <a href=\"https://www.cisa.gov/news-events/news/best-practices-mitre-attckr-mapping\" title=\"Best Practices for MITRE ATT&amp;CK Mapping\">Best Practices for MITRE ATT&amp;CK Mapping</a> and CISA\u2019s <a href=\"https://github.com/cisagov/Decider/\" title=\"Decider Tool\">Decider Tool</a>.</p>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><a class=\"ck-anchor\" id=\"Table2\"></a>Table 2. Initial Access</caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Technique Title</th>\n<th role=\"columnheader\">ID</th>\n<th role=\"columnheader\">Use</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Internet Accessible Device</td>\n<td><a href=\"https://attack.mitre.org/versions/v18/techniques/T0883/\" target=\"_blank\" title=\"T0833\">T0883</a></td>\n<td>The actors used Rockwell Automation\u2019s programming software (such as Studio 5000 Logix Designer) to access and interact with publicly exposed, internet-accessible PLCs installed and deployed without sufficient network and/or hardening security controls.&nbsp;</td>\n</tr>\n</tbody>\n</table>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><a class=\"ck-anchor\" id=\"Table3\"></a>Table 3. Impact</caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Technique Title</th>\n<th role=\"columnheader\">ID</th>\n<th role=\"columnheader\">Use</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Stored Data Manipulation</td>\n<td><a href=\"https://attack.mitre.org/techniques/T1565/\" target=\"_blank\" title=\"T1565\">T1565</a></td>\n<td>The actors maliciously interacted with project files and altered data displayed on HMI and SCADA displays</td>\n</tr>\n</tbody>\n</table>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<caption><a class=\"ck-anchor\" id=\"Table4\"></a>Table 4. Command and Control</caption>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Technique Title</th>\n<th role=\"columnheader\">ID</th>\n<th role=\"columnheader\">Use</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>Commonly Used Port</td>\n<td><a href=\"https://attack.mitre.org/techniques/T0885/\" target=\"_blank\" title=\"T0885\">T0885</a></td>\n<td>The actors used commonly used OT ports to communicate with PLCs.</td>\n</tr>\n<tr>\n<td>Remote Access Tools&nbsp;</td>\n<td><a href=\"https://attack.mitre.org/versions/v18/techniques/T1219/\" target=\"_blank\" title=\"T1219\">T1219</a></td>\n<td>The actors deployed Dropbear SSH software on victim endpoints to enable them to gain remote access through port <code>22</code>.</td>\n</tr>\n</tbody>\n</table>\n<h2><a class=\"ck-anchor\" id=\"Mitigations\"><strong>Mitigations</strong></a></h2>\n<p>The authoring agencies recommend organizations implement the mitigations below to improve your organization\u2019s cybersecurity posture on the basis of the threat actors\u2019 activity. These mitigations align with the Cross-Sector Cybersecurity Performance Goals 2.0 (CPGs 2.0) developed by CISA and the National Institute of Standards and Technology (NIST). The CPGs provide a minimum set of practices and protections that CISA and NIST recommend all organizations implement. CISA and NIST based the CPGs on existing cybersecurity frameworks and guidance to protect against the most common and impactful threats, tactics, techniques, and procedures. Visit CISA\u2019s <a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0\" title=\"CPG 2.0\">CPG 2.0</a> webpage for more information on the CPGs, including additional recommended baseline protections.</p>\n<h3><strong>Network Defenders</strong></h3>\n<p>The cyber threat actors accessed Rockwell Automation/Allen-Bradley-manufactured PLCs to cause disruptions to victim systems. To safeguard against this threat and threats to other types of PLCs, the authoring agencies urge organizations to consider the following mitigations.</p>\n<p>In addition, organizations with these PLCs should view Rockwell Automation\u2019s guidance: <a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1771.html\" target=\"_blank\" title=\"Rockwell Automation Reiterates Customer Guidance to Disconnect Devices from the Internet and Harden PLCs to Protect from Cyber Threats\">Rockwell Automation Reiterates Customer Guidance to Disconnect Devices from the Internet and Harden PLCs to Protect from Cyber Threats</a>.</p>\n<p><strong>Immediate steps to prevent the attack:</strong></p>\n<ul>\n<li><strong>Disconnect the PLC from the public-facing internet</strong> [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#SecureInternetFacingDevices3S\" title=\"CPG 3.S\">CPG 3.S</a>]. Follow the joint guidance <a href=\"https://www.ncsc.gov.uk/collection/operational-technology/secure-connectivity\" target=\"_blank\" title=\"Secure Connectivity Principles for OT\">Secure connectivity principles for OT</a> to safely allow remote access. Specifically, \u201cremove inbound port exposure,\u201d so the OT system is never directly exposed to the internet or external networks, and to ensure all access is mediated, monitored, and controlled. Do this through a secure gateway (jump host) that brokers the connection.\n<ul>\n<li>Ensure cellular modems, used for remote field connectivity and access, are secured with strong authentication and updated.</li>\n<li>Enable logs for the connected modems to detect intrusion and improve incident response speed.</li>\n</ul>\n</li>\n<li><strong>For controllers with a physical mode switch, place the physical mode switch into run position to prevent remote modification.&nbsp;</strong>Devices should only be in the program or remote position when updating or downloading software online and immediately switched back to the run position when complete.&nbsp;(See Rockwell\u2019s<a href=\"#Note2\"><sup>2</sup></a><sup> </sup><a href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/rm/secure-rm001_-en-p.pdf\" target=\"_blank\" title=\"System Security Design Guidelines\">System Security Design Guidelines</a> for manufacturer\u2019s instructions.)</li>\n<li><strong>For devices that allow for software key switching,&nbsp;</strong>enable programming protection in PLC configuration software (S7 Totally Integrated Automation [TIA] Portal) to limit who can modify PLCs remotely. (See Siemens\u2019 <a href=\"https://assets.new.siemens.com/siemens/assets/api/uuid:c9a2de6e-6bd0-4c32-bba0-f64cac44fcc9/industrial-security-operational-guidelines-en.pdf\" target=\"_blank\">Cybersecurity for Industry Operational Guidelines</a> for the manufacturer\u2019s instructions.)</li>\n<li><strong>Create and test strong backups of the logic and configurations of PLCs</strong>. Store backup files offline and secure the physical removal media to enable fast recovery.</li>\n</ul>\n<p><strong>Follow-up steps to strengthen security posture:</strong></p>\n<ul>\n<li><strong>Implement multifactor authentication</strong> <strong>(MFA)</strong> [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#ImplementMultifactorAuthentication3F\" title=\"CPG 3.F\">CPG 3.F</a>] for access to the OT network from an external network.</li>\n<li>If remote access is required, <strong>implement a network proxy, gateway, firewall, and/or virtual private network (VPN) in front of the PLC to control network access</strong>.\n<ul>\n<li>A VPN or gateway device can enable MFA for remote access even if the PLC does not support MFA. Implement security rules on these higher-level network security mechanisms that prevent the type of repeated and sustained login attempts that would be seen during a brute force attack. When possible, implement a device control list for workstations sending messages or connecting to OT components.</li>\n<li>Use the device control list to monitor for logon activity for unexpected or unusual access to devices from the internet.</li>\n</ul>\n</li>\n<li><strong>Keep PLC devices updated with the latest software patches by the manufacturer.</strong> Use established downtime windows to install patches. <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" title=\"Known Exploited Vulnerabilities\">Known Exploited Vulnerabilities</a> may need to be prioritized outside a downtime window.</li>\n<li><strong>Configure external and internal firewalls to block traffic using common ports&nbsp;</strong>associated with network protocols that are unnecessary for the particular network segment.</li>\n<li><strong>Disable any unused authentication methods, logic, or features,&nbsp;</strong>such as default authentication keys, as well as unused or needed services such as Teletype Network (Telnet), File Transfer Protocol (FTP), Remote Desktop Protocol (RDP), Virtual Network Computing (VNC), and web services.</li>\n<li><strong>Monitor asset management systems for device configuration changes</strong>, which can be used to understand expected parameter settings.</li>\n<li><strong>Monitor the content of network traffic</strong> for the following:\n<ul>\n<li>Unusual logins to internet-connected devices or unexpected protocols to/from the internet.</li>\n<li>Functions of industrial control systems (ICS) management protocols that change an asset\u2019s operating mode or modify programs.</li>\n</ul>\n</li>\n</ul>\n<p>In addition, the authoring agencies recommend network defenders apply the following mitigations to limit potential adversarial use of common system and network discovery techniques, as well as reduce the impact and risk of compromise by cyber threat actors:</p>\n<ul>\n<li><strong>Reduce risk exposure</strong>. CISA offers a range of services at no cost, including scanning and testing, to help organizations reduce exposure to threats via mitigating attack vectors. CISA\u2019s <a href=\"https://www.cisa.gov/cyber-hygiene-services\" title=\"Cyber Hygiene Services\">Cyber Hygiene Services</a> can help provide additional review of organizations\u2019 internet accessible assets.&nbsp;</li>\n</ul>\n<h3><strong>Device Manufacturers</strong></h3>\n<p><strong>Note:</strong> The following guidance is general in nature and not specific to any OT vendor. Some of the features, settings, and practices may already be offered by certain vendors. The inclusion of this guidance should not be interpreted as an assertion that vendors referenced in this product do not offer such security features.</p>\n<p>Although critical infrastructure organizations using PLC devices can take steps to mitigate the risks, it is ultimately the responsibility of the device manufacturer to build products that are secure by design and default. The authoring agencies urge device manufacturers to take ownership of their customers\u2019 security outcomes by following the principles in the joint guide <a href=\"https://www.cisa.gov/resources-tools/resources/secure-demand-priority-considerations-operational-technology-owners-and-operators-when-selecting\" title=\"Secure by Demand: Priority Considerations for Operational Technology Owners and Operators when Selecting Digital Products\">Secure by Demand: Priority Considerations for OT Owners and Operators when Selecting Digital Products</a>, primarily:</p>\n<ul>\n<li>Change the manufacturers\u2019 default settings to prevent exposing administrative interfaces to the internet.</li>\n<li>Do not charge additional fees for basic security features needed to operate the product securely.</li>\n<li>Support MFA, including via phishing-resistant methods.</li>\n</ul>\n<p>By using secure by design tactics, software manufacturers can make product lines secure \u201cout of the box\u201d without requiring customers to spend additional resources making configuration changes, purchasing tiered security software and logs, monitoring, and making routine updates.</p>\n<p>For more information on common misconfigurations and guidance on reducing their prevalence, see joint advisory <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-278a\" title=\"NSA and CISA Red and Blue Teams Share Top Ten Cybersecurity Misconfigurations\">NSA and CISA Red and Blue Teams Share Top Ten Cybersecurity Misconfigurations</a>. For more information on secure by design, see CISA\u2019s <a href=\"https://www.cisa.gov/securebydesign\" title=\"Secure by Design\">Secure by Design</a> webpage and joint guide.</p>\n<h2><strong>Validate Security Controls</strong></h2>\n<p>In addition to applying mitigations, the authoring agencies recommend exercising, testing, and validating your organization's security program against the threat behaviors mapped to the MITRE ATT&amp;CK for Enterprise framework in this advisory. The authoring agencies recommend testing your existing security controls inventory to assess how they perform against the ATT&amp;CK techniques described in this advisory.</p>\n<p>To get started:</p>\n<ol>\n<li>Select an ATT&amp;CK technique described in this advisory (see <a href=\"#Table2\"><strong>Table 2</strong></a> to <a href=\"#Table4\"><strong>Table 4</strong></a>).</li>\n<li>Align your security technologies against the technique.</li>\n<li>Test your technologies against the technique.</li>\n<li>Analyze your detection and prevention technologies\u2019 performance.</li>\n<li>Repeat the process for all security technologies to obtain a set of comprehensive performance data.</li>\n<li>Tune your security program, including people, processes, and technologies, based on the data generated by this process.</li>\n</ol>\n<p>The authoring agencies recommend continually testing your security program, at scale, in a production environment to ensure optimal performance against the MITRE ATT&amp;CK techniques identified in this advisory.</p>\n<h2><strong>Resources</strong></h2>\n<ul>\n<li>Authoring Agencies: <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-335a\" title=\"IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities\">IRGC-Affiliated Cyber Actors Exploit PLCs in Multiple Sectors, Including US Water and Wastewater Systems Facilities</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/resources-tools/resources/bulletproof-defense-mitigating-risks-bulletproof-hosting-providers\" title=\"Bulletproof Defense: Mitigating Risks From Bulletproof Hosting Providers\">Bulletproof Defense: Mitigating Risks From Bulletproof Hosting Providers</a></li>\n<li>EPA: <a href=\"https://www.epa.gov/cyberwater/epa-cybersecurity-water-sector\" target=\"_blank\" title=\"Cybersecurity for the Water Sector\">Cybersecurity for the Water Sector</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/water\" title=\"Water and Wastewater Cybersecurity\">Water and Wastewater Systems Sector</a></li>\n<li>CISA Alert: <a href=\"https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems\" title=\"Exploitation of Unitronics PLCs used in Water and Wastewater Systems\">Exploitation of Unitronics PLCs used in Water and Wastewater Systems</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/topics/cyber-threats-and-advisories/advanced-persistent-threats/iran\" title=\"Iran Cyber Threat Overview and Advisories\">Iran Threat Overview and Advisories</a></li>\n<li>FBI: <a href=\"https://www.fbi.gov/investigate/counterintelligence/the-iran-threat\" target=\"_blank\" title=\"The Iran Threat\">The Iran Threat</a></li>\n<li>CISA, MITRE: <a href=\"https://www.cisa.gov/news-events/news/best-practices-mitre-attckr-mapping\" title=\"Best Practices for MITRE ATT&amp;CK Mapping\">Best Practices for MITRE ATT&amp;CK Mapping</a></li>\n<li>CISA: <a href=\"https://github.com/cisagov/Decider/\" title=\"Decider Tool\">Decider Tool</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0\" title=\"Cross-Sector Cybersecurity Performance Goals 2.0\">Cross-Sector Cybersecurity Performance Goals 2.0</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/topics/cyber-threats-and-advisories/cyber-hygiene-services\" title=\"No-Cost Cybersecurity Services and Tools\">No-Cost Cybersecurity Services and Tools</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/resources-tools/resources/secure-demand-priority-considerations-operational-technology-owners-and-operators-when-selecting\" title=\"Secure by Demand: Priority Considerations for Operational Technology Owners and Operators when Selecting Digital Products\">Secure by Demand: Priority Considerations for Operational Technology Owners and Operators when Selecting Digital Products</a></li>\n<li>NSA, CISA: <a href=\"https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-278a\" title=\"NSA and CISA Red and Blue Teams Share Top Ten Cybersecurity Misconfigurations\">NSA and CISA Red and Blue Teams Share Top Ten Cybersecurity Misconfigurations</a></li>\n<li>CISA: <a href=\"https://www.cisa.gov/securebydesign\" title=\"Secure by Design\">Secure by Design</a></li>\n<li>FBI: <a href=\"https://www.ic3.gov/CSA/2025/250506.pdf\" target=\"_blank\" title=\"Primary Mitigations to Reduce Cyber Threats to Operational Technology\">Primary Mitigations to Reduce Cyber Threats to Operational Technology</a></li>\n<li>United Kingdom National Cyber Security Center: <a href=\"https://www.ic3.gov/CSA/2026/260114.pdf\" target=\"_blank\" title=\"Secure Connectivity Principles for Operational Technology (OT)\">Secure connectivity principles for operational technology (OT)</a></li>\n</ul>\n<h2><a class=\"ck-anchor\" id=\"Contact\"><strong>Contact Information</strong></a></h2>\n<p>U.S. organizations are encouraged to report suspicious or criminal activity related to information in this advisory to CISA, FBI, and/or NSA:</p>\n<ul>\n<li>Contact CISA via CISA\u2019s 24/7 Operations Center at <a href=\"mailto:contact@cisa.dhs.gov\" title=\"contact@cisa.dhs.gov\">contact@cisa.dhs.gov</a> or 1-844-Say-CISA (1-844-729-2472) or your local <a href=\"https://www.fbi.gov/contact-us/field-offices\" target=\"_blank\" title=\"FBI field office\">FBI field office</a>. When available, please include the following information regarding the incident: date, time, and location of the incident; type of activity; number of people affected; type of equipment used for the activity; the name of the submitting company or organization; and a designated point of contact.</li>\n<li>For NSA cybersecurity guidance inquiries, contact <a href=\"mailto:CybersecurityReports@nsa.gov\" title=\"CybersecurityReports@nsa.gov\">CybersecurityReports@nsa.gov</a>.</li>\n<li>Entities required to report incidents to DOE should follow established reporting requirements, as appropriate. For other energy sector inquiries, contact <a href=\"mailto:EnergySRMA@hq.doe.gov\" title=\"EnergySRMA@hq.doe.gov\">EnergySRMA@hq.doe.gov</a>.</li>\n<li>Contact the Rockwell Automation PSIRT for questions regarding their guidance or for reporting cyber incidents related to Rockwell Automation at <a href=\"mailto:PSIRT@rockwellautomation.com\" title=\"PSIRT@rockwellautomation.com\">PSIRT@rockwellautomation.com</a>.</li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. The authoring agencies do not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by the authoring agencies.</p>\n<h2><strong>Version History</strong></h2>\n<p><strong>April 7, 2026</strong>: Initial version.</p>\n<h2><strong>Notes</strong></h2>\n<p><a class=\"ck-anchor\" id=\"Note1\"></a><sup>1</sup>Project file refers to the software file that contains ladder logic and configuration settings. On Rockwell Automation devices, it is referred to as an .ACD file.</p>\n<p><a class=\"ck-anchor\" id=\"Note2\"></a><sup>2 </sup>See <a href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1769-um021_-en-p.pdf\" target=\"_blank\" title=\"CompactLogix 5370 Controllers\">CompactLogix 5370 Controllers</a> (Chapter 5: \"Select the Operating Mode of the Controller\") for more information on functions available for the switch.</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 07 Apr 26 12:00:00 +0000",
        "last_updated": "Tue, 07 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/06/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/06/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35616\" target=\"_blank\">CVE-2026-35616</a> - Fortinet FortiClient EMS Improper Access Control Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\" data-entity-type=\"node\" data-entity-uuid=\"79453b83-86b9-4e2f-b1ec-abf73c6eb291\" data-entity-substitution=\"canonical\" title=\"Known Exploited Vulnerabilities Catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" data-entity-type=\"node\" data-entity-uuid=\"f2adba9a-0404-494c-a90c-4363a4a5c934\" data-entity-substitution=\"canonical\" title=\"Reducing the Significant Risk of Known Exploited Vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 06 Apr 26 12:00:00 +0000",
        "last_updated": "Mon, 06 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-01",
        "title": "Siemens SICAM 8 Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-092-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - RTUM85 for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE - RTUM85 Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens SICAM 8 Products are affected:</p>\n<ul>\n<li>CPCI85 Central Processing/Communication vers:intdot/&lt;26.10 (CVE-2026-27663, CVE-2026-27664)</li>\n<li>RTUM85&nbsp;RTU Base vers:intdot/&lt;26.10 (CVE-2026-27663)</li>\n<li>SICORE Base system vers:intdot/&lt;26.10.0 (CVE-2026-27664)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Siemens</td>\n<td>Siemens SICAM 8 Products</td>\n<td>Allocation of Resources Without Limits or Throttling, Out-of-bounds Write</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM 8 Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CPCI85 Central Processing/Communication, RTUM85&nbsp;RTU Base</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware RTUM85 V26.10 is present within \u201cCP-8010/CP-8012 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within \u201cSICAM S8000 Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109818240</p>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware CPCI85 V26.10 is present within \u201cCP-8031/CP-8050 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within \u201cSICAM EGS Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109972536/</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-27664</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-27664\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SICAM 8 Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CPCI85 Central Processing/Communication, SICORE Base system</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V26.10 or later version The firmware CPCI85 V26.10 is present within \u201cCP-8031/CP-8050 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within \u201cSICAM EGS Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109972536/</p>\n<p><strong>Vendor fix</strong><br>Update to V26.10.0 or later version The firmware SICORE V26.10.0 is present within \u201cCP-8010/CP-8012 Package\u201d V26.10 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within \u201cSICAM S8000 Package\u201d V26.10 https://support.industry.siemens.com/cs/document/109818240</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>T. Weber, S. Dietz, D. Blagojevic, and F. Koroknai of CyberDanube coordinated disclosure of CVE-2026-27663</li>\n<li>S. Dietz of CyberDanube and VERBUND Digital Power coordinated disclosure of CVE-2026-27664</li>\n<li>S. Dietz of Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-246443 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-26</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-04-02</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-246443 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/04/02/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/04/02/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added&nbsp;one&nbsp;new&nbsp;vulnerability&nbsp;to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-3502\" target=\"_blank\">CVE-2026-3502</a>&nbsp;TrueConf&nbsp;Client Download of Code Without Integrity Check Vulnerability&nbsp;</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV&nbsp;Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a>&nbsp;for more information.&nbsp;</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing&nbsp;timely&nbsp;remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>&nbsp;as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-02",
        "title": "Yokogawa CENTUM VP",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-092-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-092-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to login as the PROG user and modify permissions.</strong></p>\n<p>The following versions of Yokogawa CENTUM VP are affected:</p>\n<ul>\n<li>CENTUM VP &gt;=R5.01.00|</li>\n<li>CENTUM VP &gt;=R6.01.00|</li>\n<li>CENTUM VP vR7.01.00 (CVE-2025-7741)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 4</td>\n<td>Yokogawa</td>\n<td>Yokogawa CENTUM VP</td>\n<td>Use of Hard-coded Password</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Food and Agriculture</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7741</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected products contain a hardcoded password for the user account (PROG) used for CENTUM Authentication Mode within the system. Under the following conditions, there is a risk that an attacker could log in as the PROG user. The default permission for the PROG users is S1 permission (equivalent to OFFUSER). Therefore, for properly permission-controlled targets of operation and monitoring, even if an attacker logs in as the PROG user, the risk of critical operations or configuration changes being performed is considered low. If the PROG user's permissions have been changed for any reason, there is a risk that operations or configuration changes may be performed under the modified permissions. Additionally, exploiting this vulnerability requires an attacker to already have access to the HIS screen controls.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7741\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Yokogawa CENTUM VP</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Yokogawa</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Yokogawa CENTUM VP: &gt;=R5.01.00|&lt;R5.04.20, Yokogawa CENTUM VP: &gt;=R6.01.00|&lt;R6.12.00, Yokogawa CENTUM VP: vR7.01.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Yokogawa recommends users applying the following mitigations to affected versions:</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R5.01.00 to R5.04.20: Change the user authentication mode to Windows Authentication Mode.</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R6.01.00 to R6.12.00: Change the user authentication mode to Windows Authentication Mode.</p>\n<p><strong>Vendor fix</strong><br>CENTUM VP R7.01.00: Apply patch software R7.01.10.</p>\n<p><strong>Mitigation</strong><br>NOTE:Changing to Windows Authentication Mode requires engineering work. If users wish to make this change, please contact Yokogawa directly https://contact.yokogawa.com/cs/gw?c-id=000498.<br><a href=\"https://contact.yokogawa.com/cs/gw?c-id=000498\">https://contact.yokogawa.com/cs/gw?c-id=000498</a></p>\n<p><strong>Mitigation</strong><br>For more information and details on implementing these mitigations, users should see the Yokogawa advisory YSAR-26-0003 at https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf<br><a href=\"https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf\">https://web-material3.yokogawa.com/1/39281/files/YSAR-26-0003-E.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/259.html\">CWE-259 Use of Hard-coded Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Yokogawa reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-04-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-04-02</td>\n<td>1</td>\n<td>Initial Republication of YSAR-26-0003</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Apr 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Apr 26 12:00:00 +0000"
    }
]