Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Apr 23, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)

View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access…
Read full source summary
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) are affected: RUGGEDCOM CROSSBOW Station Access Controller (SAC) vers:intdot/<5.8 (CVE-2025-6965) CVSS Vendor Equipment Vulnerabilities v3 7.7 Siemens Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Numeric Truncation Error Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-6965 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above. View CVE Details Affected Products Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Vendor: Siemens Product Version: RUGGEDCOM CROSSBOW Station Access Controller (SAC) Product Status: known_affected Remediations Vendor fix Update to V5.8 or later version https://support.industry.siemens.com/cs/ww/en/view/110000841/ Relevant CWE: CWE-197 Numeric Truncation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-225816 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-225816 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

​​Supply Chain Compromise Impacts Axios Node Package Manager​

The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this alert to provide guidance in response to the software supply chain compromise of the Axios node package manager (npm).1 Axios is an HTTP client for JavaScript that developers commonly use in Node.js and browser environments. On March 31, 2026, two npm packages for versions axios@1.14.1 and axios@0.30.4 of Axios npm injected the malicious…
Read full source summary
The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this alert to provide guidance in response to the software supply chain compromise of the Axios node package manager (npm).1 Axios is an HTTP client for JavaScript that developers commonly use in Node.js and browser environments. On March 31, 2026, two npm packages for versions axios@1.14.1 and axios@0.30.4 of Axios npm injected the malicious dependency plain-crypto-js@4.2.1 that downloads multi-stage payloads from cyber threat actor infrastructure, including a remote access trojan.2 CISA urges organizations to implement the following recommendations to detect and remediate a potential compromise: Monitor and review code repositories, continuous integration/continuous delivery (CI/CD) pipelines, and developer machines that ran npm install or npm update with the compromised Axios version. Search for cached versions of affected dependencies in artifact repositories and dependency management tools. Pin npm package dependency versions to known safe releases. If compromised dependencies are identified, revert the environment to a known safe state. Downgrade to axios@1.14.0 or axios@0.30.3 and delete node_modules/plain-crypto-js/. Rotate/revoke credentials that may have been exposed on affected systems or pipelines (e.g., version control system [VCS] tokens, CI/CD secrets, cloud keys, npm tokens, and Secure Shell [SSH] keys). For ephemeral CI jobs, rotate all secrets injected into the compromised run. Monitor for unexpected child processes and anomalous network behavior, specifically during npm install or npm update. Block and monitor outbound connections to Sfrclak[.]com domains. Conduct continuous indicator searches and endpoint detection and response (EDR) hunts to confirm no indicators of compromise (IOCs) remain; ensure no further egress to the command and control (C2). In addition, CISA recommends organizations using Axios npm: Mandate phishing-resistant multifactor authentication (MFA) on all developer accounts, especially for critical platforms. Set ignore-scripts=true in the .npmrc configuration file, which prevents potentially malicious scripts from executing during npm install packages. Set min-release-age=7 in the .npmrc configuration file to only install packages that have been published for at least seven days, which helps avoid installation of packages that may not be completely vetted or are potentially malicious. Establish and maintain a baseline of normal execution behavior for tools that use Axios. Alert when a dependency behaves differently (e.g., building containers, enabling shells, executing commands) and trace outbound network activity for anomalous connections. See the following resources for additional guidance on this compromise: GitHub: Post Mortem: axios npm supply chain compromise #10636 Microsoft: Mitigating the Axios npm supply chain compromise StepSecurity: axios Compromised on npm - Malicious Versions Drop Remote Access Trojan npm Docs: Securing your code Socket: Supply Chain Attack on Axios Pulls Malicious Dependency from npm Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Notes 1 “Post Mortem: axios npm supply chain compromise,” axios GitHub, Issue #10636, March 31, 2026, https://github.com/axios/axios/issues/10636. 2 “Mitigating the Axios npm supply chain compromise,” Microsoft Threat Intelligence and Microsoft Defender Security Research Team, April 1, 2026, https://www.microsoft.com/en-us/security/blog/2026/04/01/mitigating-the-axios-npm-supply-chain-compromise/.
· CISA Cybersecurity Advisory

CISA Adds Eight Known Exploited Vulnerabilities to Catalog

CISA has added eight new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-27351 PaperCut NG/MF Improper Authentication Vulnerability CVE-2024-27199 JetBrains TeamCity Relative Path Traversal Vulnerability CVE-2025-2749 Kentico Xperience Path Traversal Vulnerability CVE-2025-32975 Quest KACE Systems Management Appliance (SMA) Improper…
Read full source summary
CISA has added eight new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-27351 PaperCut NG/MF Improper Authentication Vulnerability CVE-2024-27199 JetBrains TeamCity Relative Path Traversal Vulnerability CVE-2025-2749 Kentico Xperience Path Traversal Vulnerability CVE-2025-32975 Quest KACE Systems Management Appliance (SMA) Improper Authentication Vulnerability CVE-2025-48700 Synacor Zimbra Collaboration Suite (ZCS) Cross-site Scripting Vulnerability CVE-2026-20122 Cisco Catalyst SD-WAN Manager Incorrect Use of Privileged APIs Vulnerability CVE-2026-20128 Cisco Catalyst SD-WAN Manager Storing Passwords in a Recoverable Format Vulnerability CVE-2026-20133 Cisco Catalyst SD-WAN Manager Exposure of Sensitive Information to an Unauthorized Actor Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

AVEVA Pipeline Simulation

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify simulation parameters, training configuration and training records. The following versions of AVEVA Pipeline Simulation are affected: Pipeline Simulation <=2025_SP1_build_7.1.9497.6351 CVSS Vendor Equipment Vulnerabilities v3 9.1 AVEVA AVEVA Pipeline Simulation Missing Authorization Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify simulation parameters, training configuration and training records. The following versions of AVEVA Pipeline Simulation are affected: Pipeline Simulation <=2025_SP1_build_7.1.9497.6351 CVSS Vendor Equipment Vulnerabilities v3 9.1 AVEVA AVEVA Pipeline Simulation Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-5387 The vulnerability, if exploited, could allow an unauthenticated miscreant to perform operations intended only for Simulator Instructor or Simulator Developer (Administrator) roles, resulting in privilege escalation with potential for modification of simulation parameters, training configuration, and training records. View CVE Details Affected Products AVEVA Pipeline Simulation Vendor: AVEVA Product Version: AVEVA Pipeline Simulation: <=2025_SP1_build_7.1.9497.6351 Product Status: known_affected Remediations Vendor fix All affected versions can be fixed by upgrading to AVEVA Pipeline Simulation 2025 SP1 P01 (build 7.1.9580.8513) or higher. (https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f) https://softwaresupportsp.aveva.com/en-US/downloads/products/details/57b79fdb-7b5f-4125-8a44-833b6b5c6d6f Mitigation For more information, please see AVEVA's security bulletin AVEVA-2026-004 (https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf). https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-004.pdf Vendor fix Restrict Network Access: Implement host-based and/or network firewall controls on all nodes hosting the Pipeline Simulation Server API to ensure that only trusted Pipeline Simulation client systems are permitted to establish connections. Mitigation Enforce Secure Communication: Enable TLS for all API communications and ensure that server certificates are properly managed and protected to reduce the risk of manipulator-in-the-middle(MitM) attacks and tampering with data in transit. Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments AVEVA reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Republication of AVEVA-2026-004 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-34197 Apache ActiveMQ Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-34197 Apache ActiveMQ Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Delta Electronics ASDA-Soft

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics ASDA-Soft are affected: ASDA-Soft <=V7.2.2.0 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics ASDA-Soft Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics ASDA-Soft are affected: ASDA-Soft <=V7.2.2.0 CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics ASDA-Soft Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-5726 A stack-based buffer overflow vulnerability is triggered in ASDA-Soft version 7.2.0.0 during the parsing of malformed .par files. View CVE Details Affected Products Delta Electronics ASDA-Soft Vendor: Delta Electronics Product Version: Delta Electronics ASDA-Soft: <=V7.2.2.0 Product Status: known_affected Remediations Vendor fix Delta Electronics recommends users download and upgrade ASDA-Soft to v7.2.6.0 or later. If you have any product-related support concerns, contact Delta via the portal page at https://www.deltaww.com/en-US/service-support/contact-us?type=1 for any information or materials you may require. https://www.deltaww.com/en-US/service-support/contact-us?type=1 Mitigation Delta Electronics provides the following general recommendations: Do not click on untrusted internet links or open unsolicited attachments in emails. Avoid exposing control systems and equipment to the Internet. Place control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use a secure access method, such as a virtual private network (VPN). Mitigation For more information, see Delta Electronics advisory Delta-PCSA-2026-00007 athttps://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00007_ASDA-Soft%20Stack-based%20Buffer%20Overflow%20Vulnerability%20(CVE-2026-5726).pdf Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Feng Xiong of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Horner Automation Cscape and XL4, XL7 PLC

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services. The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected: Cscape v10.0 XL7 PLC v15.60 XL4 PLC v16.32.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Horner Automation Horner Automation Cscape and XL4, XL7 PLC Weak Password Requirements Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services. The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected: Cscape v10.0 XL7 PLC v15.60 XL4 PLC v16.32.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Horner Automation Horner Automation Cscape and XL4, XL7 PLC Weak Password Requirements Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6284 An attacker with network access to the PLC is able to brute force discover passwords to gain unauthorized access to systems and services. The limited password complexity and no password input limiters makes brute force password enumeration possible. View CVE Details Affected Products Horner Automation Cscape and XL4, XL7 PLC Vendor: Horner Automation Product Version: Horner Automation Cscape: v10.0, Horner Automation XL7 PLC: v15.60, Horner Automation XL4 PLC: v16.32.0 Product Status: known_affected Remediations Vendor fix Horner Automation recommends users update to Cscape v10.2 SP2 or later. Horner Automation has also released the latest firmware for both XL4 and XL7 PLCs. Horner recommends users update to the latest version of the firmware. https://hornerautomation.com/cscape-software-free/cscape-software/. https://hornerautomation.com/cscape-software-free/cscape-software/ Mitigation For more information, see Horner Automation's release notes. Relevant CWE: CWE-521 Weak Password Requirements Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments An anonymous researcher reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Anviz Multiple Products

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to conduct reconnaissance, capture or decrypt sensitive data, alter device configurations, gain unauthorized administrative or root‑level access, execute arbitrary code, compromise credentials or communications, and ultimately obtain full control over affected devices. The following versions of Anviz Multiple Products are…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to conduct reconnaissance, capture or decrypt sensitive data, alter device configurations, gain unauthorized administrative or root‑level access, execute arbitrary code, compromise credentials or communications, and ultimately obtain full control over affected devices. The following versions of Anviz Multiple Products are affected: CX2 Lite Firmware vers:all/* (CVE-2026-32648, CVE-2026-40461, CVE-2026-35682, CVE-2026-35546, CVE-2026-40066, CVE-2026-33569) CX7 Firmware vers:all/* (CVE-2026-33093, CVE-2026-35061, CVE-2026-32648, CVE-2026-40461, CVE-2026-35546, CVE-2026-40066, CVE-2026-32324, CVE-2026-31927, CVE-2026-33569) CrossChex Standard vers:all/* (CVE-2026-40434, CVE-2026-32650) CVSS Vendor Equipment Vulnerabilities v3 9.8 Anviz Anviz Multiple Products Missing Authorization, Missing Authentication for Critical Function, Improper Neutralization of Special Elements used in a Command ('Command Injection'), Download of Code Without Integrity Check, Use of Hard-coded Cryptographic Key, Relative Path Traversal, Cleartext Transmission of Sensitive Information, Improper Verification of Source of a Communication Channel, Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Defense Industrial Base, Energy, Financial Services, Food and Agriculture, Government Services and Facilities, Healthcare and Public Health, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-33093 CX7 is vulnerable to an unauthenticated POST to the device that captures a photo with the front facing camera, exposing visual information about the deployment environment. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-35061 CX7 is vulnerable to the most recently captured test photo that can be retrieved without authentication, revealing sensitive operational imagery. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-32648 CX2 Lite and CX7 are vulnerable to unauthenticated access that discloses debug configuration details (e.g., SSH/RTTY status), assisting attackers in reconnaissance against the device. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-40461 CX2 Lite and CX7 are vulnerable to unauthenticated POST requests that modify debug settings (e.g., enabling SSH), allowing unauthorized state changes that can facilitate later compromise. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2026-35682 CX2 Lite is vulnerable to an authenticated command injection via a filename parameter that enables arbitrary command execution (e.g., starting telnetd), resulting in root‑level access. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-35546 CX2 Lite and CX7 are vulnerable to unauthenticated firmware uploads. This causes crafted archives to be accepted, enabling attackers to plant and execute code and obtain a reverse shell. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-40066 CX2 Lite and CX7 are vulnerable to unverified update packages that can be uploaded. The device unpacks and executes a script resulting in unauthenticated remote code execution. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-494 Download of Code Without Integrity Check Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-32324 CX7 is vulnerable because the application embeds reusable certificate/key material, enabling decryption of MQTT traffic and potential interaction with device messaging channels at scale. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2026-31927 CX7 is vulnerable to an authenticated CSV upload which allows path traversal to overwrite arbitrary files (e.g., /etc/shadow), enabling unauthorized SSH access when combined with debug‑setting changes. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.9 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N CVE-2026-33569 CX2 Lite and CX7 administrative sessions occur over HTTP, enabling on‑path attackers to sniff credentials and session data, which can be used to compromise the device. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CX2 Lite Firmware: vers:all/*, Anviz CX7 Firmware: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N CVE-2026-40434 CrossChex Standard lacks source verification in the client/server channel, enabling TCP packet injection by an attacker on the same network to alter or disrupt application traffic. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CrossChex Standard: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-32650 CrossChex Standard is vulnerable when an attacker manipulates the TDS7 PreLogin to disable encryption, causing database credentials to be sent in plaintext and enabling unauthorized database access. View CVE Details Affected Products Anviz Multiple Products Vendor: Anviz Product Version: Anviz CrossChex Standard: vers:all/* Product Status: known_affected Remediations Mitigation Anviz did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Anviz for more information at https://www.anviz.com/contact-us.html. https://www.anviz.com/contact-us.html Relevant CWE: CWE-757 Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments An anonymous researcher reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-16 Date Revision Summary 2026-04-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2009-0238 Microsoft Office Remote Code Execution Vulnerability CVE-2026-32201 Microsoft SharePoint Server Improper Input Validation Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2009-0238 Microsoft Office Remote Code Execution Vulnerability CVE-2026-32201 Microsoft SharePoint Server Improper Input Validation Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds Seven Known Exploited Vulnerabilities to Catalog

CISA has added seven new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2012-1854 Microsoft Visual Basic for Applications Insecure Library Loading Vulnerability CVE-2020-9715 Adobe Acrobat Use-After-Free Vulnerability CVE-2023-21529 Microsoft Exchange Server Deserialization of Untrusted Data Vulnerability CVE-2023-36424 Microsoft Windows…
Read full source summary
CISA has added seven new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2012-1854 Microsoft Visual Basic for Applications Insecure Library Loading Vulnerability CVE-2020-9715 Adobe Acrobat Use-After-Free Vulnerability CVE-2023-21529 Microsoft Exchange Server Deserialization of Untrusted Data Vulnerability CVE-2023-36424 Microsoft Windows Out-of-Bounds Read Vulnerability CVE-2025-60710 Microsoft Windows Link Following Vulnerability CVE-2026-21643 Fortinet SQL Injection Vulnerability CVE-2026-34621 Adobe Acrobat and Reader Prototype Pollution Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Browse saved snapshots