Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Apr 27, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-7399 Samsung MagicINFO 9 Server Path Traversal Vulnerability CVE-2024-57726 SimpleHelp Missing Authorization Vulnerability CVE-2024-57728 SimpleHelp Path Traversal Vulnerability CVE-2025-29635 D-Link DIR-823X Command Injection Vulnerability These types of vulnerabilities…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-7399 Samsung MagicINFO 9 Server Path Traversal Vulnerability CVE-2024-57726 SimpleHelp Missing Authorization Vulnerability CVE-2024-57728 SimpleHelp Path Traversal Vulnerability CVE-2025-29635 D-Link DIR-823X Command Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Carlson Software VASCO-B GNSS Receiver

View CSAF Summary Successful exploitation of this vulnerability could enable a remote attacker to alter critical system functions or disrupt device operation. The following versions of Carlson Software VASCO-B GNSS Receiver are affected: VASCO-B GNSS Receiver <1.4.0 (CVE-2026-3893) CVSS Vendor Equipment Vulnerabilities v3 9.4 Carlson Software Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could enable a remote attacker to alter critical system functions or disrupt device operation. The following versions of Carlson Software VASCO-B GNSS Receiver are affected: VASCO-B GNSS Receiver <1.4.0 (CVE-2026-3893) CVSS Vendor Equipment Vulnerabilities v3 9.4 Carlson Software Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3893 The Carlson VASCO-B GNSS Receiver lacks an authentication mechanism, allowing an attacker with network access to directly access and modify its configuration and operational functions without needing credentials. View CVE Details Affected Products Carlson Software VASCO-B GNSS Receiver Vendor: Carlson Software Product Version: Carlson Software VASCO-B GNSS Receiver: <1.4.0 Product Status: known_affected Remediations Mitigation Carlson Software recommends users update to Version 1.4.0 or greater. For more information contact Carlson Software https://www.carlsonsw.com/support-and-training/ https://www.carlsonsw.com/support-and-training/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass authentication and have remote access to sensitive information on the device. The following versions of Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera are affected: IP Camera XM530V200_X6-WEQ_8M firmware V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 (CVE-2025-65856) CVSS Vendor Equipment Vulnerabilities v3 9.8…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass authentication and have remote access to sensitive information on the device. The following versions of Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera are affected: IP Camera XM530V200_X6-WEQ_8M firmware V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 (CVE-2025-65856) CVSS Vendor Equipment Vulnerabilities v3 9.8 Hangzhou Xiongmai Technology Co., Ltd Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-65856 Authentication bypass vulnerability in Xiongmai XM530 IP cameras on Firmware V5.00.R02.000807D8.10010.346624.S.ONVIF 21.06 allows unauthenticated remote attackers to access sensitive device information and live video streams. The ONVIF implementation fails to enforce authentication on 31 critical endpoints, enabling direct unauthorized video stream access. View CVE Details Affected Products Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera Vendor: Hangzhou Xiongmai Technology Co., Ltd Product Version: Hangzhou Xiongmai Technology Co., Ltd IP Camera XM530V200_X6-WEQ_8M firmware: V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 Product Status: known_affected Remediations Mitigation Hangzhou Xiongmai Technology Co., Ltd has not responded to requests to work with CISA to mitigate this vulnerability. Users of affected versions of XM530 IP cameras are invited to contact Xiongmai Technology customer support for additional information (https://www.xiongmaitech.com/en/index.php/about/contact/42). https://www.xiongmaitech.com/en/index.php/about/contact/42 Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments CISA discovered a public Proof of Concept (PoC) as authored by Luis Miranda Acebedo and reported it to MITRE Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-39987 Marimo Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-39987 Marimo Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

FIRESTARTER Backdoor

Malware Analysis Report at a Glance Malware Name FIRESTARTER Original Publication April 23, 2026 Executive Summary The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess advanced persistent threat (APT) actors are using FIRESTARTER malware for persistence,…
Read full source summary
Malware Analysis Report at a Glance Malware Name FIRESTARTER Original Publication April 23, 2026 Executive Summary The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess advanced persistent threat (APT) actors are using FIRESTARTER malware for persistence, specifically targeting publicly accessible Cisco Firepower and Secure Firewall devices running Adaptive Security Appliance (ASA) or Firepower Threat Defense (FTD) software. CISA and the NCSC are releasing this Malware Analysis Report to share analysis of one FIRESTARTER malware sample operating as a backdoor and urge organizations to take key response actions. Note: The release of this Malware Analysis Report aligns with CISA’s update to V1: Emergency Directive (ED) 25-03: Identify and Mitigate Potential Compromise of Cisco Devices and Supplemental Direction ED 25-03: Core Dump and Hunt Instructions. The malware outlined in this report is relevant for both Cisco Firepower and Secure Firewall devices; however, CISA has only observed a successful implant of the malware in the wild on a Cisco Firepower device running ASA software. Key Actions for U.S. FCEB Agencies Collect and submit core dumps to CISA’s Malware Next Generation platform. Immediately report the submission via CISA’s 24/7 Operations Center; CISA will reach out with next steps. Take no additional action until CISA provides further guidance. Key Actions for All Other Organizations Use the YARA rules to detect FIRESTARTER malware against either a disk image or core dump of a device. Report any findings to CISA or the NCSC. If compromise is confirmed, conduct incident response actions. Intended Audience Organizations: Government and critical infrastructure organizations (Note: While this publication supplements CISA ED 25-03, the guidance is applicable to all organizations, including U.K. organizations.) Sector: Government Services and Facilities Sector Roles: Digital forensics analysts, incident responders, vulnerability analysts, system administrators Introduction The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess that FIRESTARTER—a backdoor that allows remote access and control—is part of a widespread campaign that afforded an advanced persistent threat (APT) actor initial access to Cisco Adaptive Security Appliance (ASA) firmware by exploiting CVE-2025-20333 [CWE-862: Missing Authorization] and/or CVE-2025-20362 [CWE-120: Classic Buffer Overflow]. For more information on this campaign, see CISA’s original version of Emergency Directive (ED) 25-03: Identify and Mitigate Potential Compromise of Cisco Devices (released Sept. 25, 2025). CISA and the NCSC assess that FIRESTARTER can persist as an active threat on Cisco devices running ASA or Firepower Threat Defense (FTD) software, maintaining post-patching persistence and enabling threat actors to re-access compromised devices without re-exploiting vulnerabilities. U.S. Federal Civilian Executive Branch (FCEB) agencies are required to implement the new required actions in CISA’s updated Emergency Directive (V1: ED 25-03). CISA and the NCSC urge other U.S. and U.K. organizations to use the YARA rules to detect FIRESTARTER malware against either a disk image or core dump of a device and report any findings to CISA or the NCSC. Organizations can also refer to Cisco’s Security Advisory and Talos Blog. Download the PDF version of this report: AR26-113A_MAR_FIRESTARTER_backdoor_ (PDF, 604.62 KB ) FIRESTARTER Collection CISA is authorized to monitor for, analyze, and notify U.S. FCEB agencies of anomalous or suspected malicious activity detected on federal networks. Through continuous monitoring, CISA identified suspicious connections on one U.S. FCEB agency’s Cisco Firepower device running ASA software. CISA notified and validated the true positive finding with agency personnel and initiated a forensic engagement. During the engagement, CISA discovered one malware sample—named FIRESTARTER—on the Firepower device. In this incident, APT actors initially deployed LINE VIPER as a post-exploitation implant and subsequently used FIRESTARTER as a persistence mechanism to maintain continued access to the compromised device. Although Cisco’s patches addressed CVE-2025-20333 and CVE-2025-20362, devices compromised prior to patching may remain vulnerable because FIRESTARTER is not removed by firmware updates. Threat Actor Activity Note: This advisory uses the MITRE ATT&CK® Matrix for Enterprise framework, version 18. See Appendix A: MITRE ATT&CK Techniques for tables mapping the cyber actors’ activity to MITRE ATT&CK tactics and techniques. CISA’s analysis identified the following: Initial Access: CISA assesses, but has not confirmed, that APT actors obtained initial access by exploiting CVE-2025-20333 and/or CVE-2025-20362 [T1190]. CISA has not confirmed the exact date of initial exploitation but assesses the compromise occurred in early September 2025, and before the agency implemented patches in accordance with ED 25-03. Privilege Escalation and Defense Evasion: CISA identified that APT actors first deployed LINE VIPER to establish illegitimate virtual private network (VPN) sessions [T1133] that bypassed all VPN authentication policies. This activity was associated with user accounts that existed but were no longer active within the agency [T1078]. Although this behavior was observed in this incident, threat actors may use other (including fabricated) accounts. LINE VIPER enabled APT actors access to all configuration elements of the victim Firepower device, including administrative credentials, certificates, and private keys [T1082]. Persistence: APT actors deployed FIRESTARTER on the Firepower device before Sept. 25, 2025 (exact date is unknown). Because it was present before patching, FIRESTARTER persisted through remediation and established command and control (C2) channels on the victim Firepower device [T1219]. APT actors leveraged FIRESTARTER to regain access without re-exploiting the original vulnerabilities and deployed LINE VIPER in March 2026. Malware Summary FIRESTARTER is a Linux Executable and Linkable File (ELF) designed to execute on Cisco Firepower and Secure Firewall devices, serving as a C2 channel for remote access and control. The malware achieves persistence by detecting termination signals and relaunching itself, and it can survive firmware updates and device reboots unless a hard power cycle occurs. FIRESTARTER attempts to install a hook—a way to intercept and modify normal operations—within LINA, the device’s core engine for network processing and security functions. This hook enables the execution of arbitrary shell code provided by the APT actors, including the deployment of LINE VIPER. Note: The file CISA obtained for analysis was named lina_cs; filenames may vary, as threat actors can easily modify the name of the malicious file. Malware Functionality Initialization Upon execution, FIRESTARTER accesses its own binary located at /usr/bin/lina_cs on the device [T1036.005] and copies its contents into memory. It then registers a callback function that triggers when the program receives any of the following termination-related signals [T1546.004]: SIGTERM SIGINT SIGQUIT SIGABRT SIGHUP SIGTSTP After copying itself into heap, and updating the signal handlers, the shell executor initiates the following sequential commands: rm /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null cp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null chmod 755 /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null chown‑reference=/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null touch‑r /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null rm /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null rm /usr/bin/lina_cs 2>/dev/null These commands delete the modified CSP_MOUNT_LIST file [T1070.004] restoring the original CSP_MOUNT_LIST. Execute permissions are granted to any user, the owner and timestamp are set to match the original [T1070.006], and the temporary file is then deleted. Finally, /usr/bin/lina_cs is deleted. Persistence and Shutdown Task When any of these signals are received or runlevel (6) is reached, the callback function is triggered and first checks whether the /opt/cisco/platform/logs/var/log/ directory exists. If absent, it creates the directory with full read/write/execute permissions [T1222]. The callback then opens /opt/cisco/platform/logs/var/log/svc_samcore.log and writes a copy of itself to this file, which is in a reboot-persistent directory. Next, the callback verifies whether /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST is present on the device. If the file is missing, FIRESTARTER creates it using a special function that can run shell commands [T1059]. After creating the file, the malware runs a series of callback commands (in sequential order) to establish persistence and manage its files: cp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null chown ‑reference=/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null touch‑r /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null Append the contents below to /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST mv /opt/cisco/platform/logs/var/log/svc_samcore.log /usr/bin/lina_cs chmod 755 /usr/bin/lina_cs lina_cs & These commands first create a temporary copy of CSP_MOUNT_LIST with the same ownership information and timestamps. A script is appended to CSP_MOUNT_LIST. This script is the persistence mechanism, which moves FIRESTARTER from its staging location, svc_samcore.log, to /usr/bin/lina_cs. It then makes it executable and runs it in the background [T1547]. This sequence ensures persistent execution of the file, even when termination signals are received. All commands redirect any standard error (stderr) messages to /dev/null and hides them from the console [T1564]. Memory Scanning and Hook Installation The process enumerates LINA’s virtual memory map to locate the private read-write (rw-p) segment associated with lina [T1057], which represents the main process’s writable data region. Once identified, this memory segment is parsed using a custom algorithm to locate the XML Handler element table. The algorithm inspects each 0x260-byte region for element IDs. After identifying five element IDs in the correct offset sequence (each separated by 0x260 bytes), it calculates and stores the handler pointer address for the seventeenth element. Shellcode Injection FIRESTARTER scans LINA’s memory to locate the executable (r-xp) segment of libstdc++.so, which corresponds to the C++ standard library’s code section. The malware injects a block of shellcode 0x200 bytes before the end of the library’s text segment, installing the detour for the XML element handler [T1055]. The process then resumes its main loop and continues operating until it detects a reboot runlevel or the termination-related signals. Victim Identification and Stage Loading The FIRESTARTER malware closely mirrors the RayInitiator Cisco ASA bootkit stage 3 deploy path. The injected shellcode is triggered when LINA processes a WebVPN request containing the XML tag with the detoured handler. Within the <group-select> element, the malware searches for a hard-coded 8-byte ASCII string unique to the installation, verifying it against a predefined value embedded in the shellcode. Additionally, a victim-specific ID—another hard-coded 8-byte sequence—is compared against WebVPN request elements until a match is found. Upon successful verification of identification, the next stage of the malware is loaded by copying it into LINA’s memory and invoking mprotect to enable execution of the newly injected code [T1543]. Detection U.S. FCEB Agency Instructions The primary detection method for FIRESTARTER is memory analysis. In accordance with V1: ED 25-03, all U.S. FCEB agencies are required to collect device core dumps and submit them to CISA’s Malware Next Generation (MNG) platform (see Incident Response section), which analyzes core dumps for the presence and behavior of the lina_cs binary. U.S. FCEB agencies should not take further action without first consulting CISA. To preserve evidence, avoid any hard power cycles and other changes (e.g., reboots, patching, configuration changes) before collection and coordination, as these can affect volatile artifacts. Other U.S. and U.K. Recommendations CISA and the NCSC recommend using the following CISA-created YARA rules to detect FIRESTARTER when applied to a disk image or a core dump from a device: To obtain a disk image, open a Cisco Technical Assistance Center (TAC) case. For instructions on obtaining a core dump, see CISA’s Supplemental Direction for ED 25-03. Note: CISA recommends following this Supplemental Direction rather than other open source resources, as APT actors commonly employ anti-forensic techniques. YARA Rules See Table 1 for a list of FIRESTARTER YARA rules. Table 1. YARA Rules FIRESTARTER Rule 1 rule CISA_261290_01 : FIRESTARTER backdoor captures_system_state_data cleans_traces_of_infection fingerprints_host persists_after_system_reboot { meta: author = "CISA Code & Media Analysis" incident = "261290" date = "2026-4-3" last_modified = "20260406_732" actor = "n/a" family = "n/a" capabilities = "captures-system-state-data cleans-traces-of-infection fingerprints-host persists-after-system-reboot" malware_type = "backdoor" tool_type = "unknown" description = "Detects CISCO Firepower FIRESTARTER injector samples" strings: $s1 = { 57 48 C1 EF 0C 48 C1 E7 0C BA 07 00 00 00 48 C7 C6 00 20 00 00 } $s2 = { 2f 6f 70 74 2f 63 69 73 63 6f 2f 70 6c 61 74 66 6f 72 6d 2f 6c 6f 67 73 2f 76 61 72 2f 6c 6f 67 2f } $s3 = { 2f 6f 70 74 2f 63 69 73 63 6f 2f 63 6f 6e 66 69 67 2f 70 6c 61 74 66 6f 72 6d 2f 72 6d 64 62 2f } $s4 = { 2f 76 61 72 2f 72 75 6e 2f 72 75 6e 6c 65 76 65 6c} $s5 = { 2f 70 72 6f 63 2f 25 73 2f 63 6f 6d 6d } $s6 = { 2f 70 72 6f 63 2f 25 64 2f 6d 61 70 73 } $s7 = { 2f 61 73 61 2f 62 69 6e 2f 6c 69 6e 61 } condition: 5 of them } FIRESTARTER Rule 2 rule CISA_261290_02 : FIRESTARTER_shellcode backdoor captures_system_state_data cleans_traces_of_infection fingerprints_host persists_after_system_reboot { meta: author = "CISA Code & Media Analysis" incident = "261290" date = "2026-4-3" last_modified = "20260406_732" actor = "n/a" family = "n/a" capabilities = "captures-system-state-data cleans-traces-of-infection fingerprints-host persists-after-system-reboot" malware_type = "backdoor" tool_type = "unknownk" description = "Detects CISCO Firepower FIRESTARTER_shellcode samples" strings: $1 = { 57 4C 8B 47 18 4D 85 C0 0F 84 C7 01 00 00 49 8B 38 48 85 FF } $2 = { 48 83 C6 08 4C 39 C6 0F 87 7A 01 00 00 4C 8B 0E } $3 = { 48 89 D7 4C 89 CE B9 D0 01 00 F3 A4 48 89 D7 57 48 C1 EF 0C 48 C1 E7 0C } $4 = { 0F 05 58 5F FF E0 90 90 } condition: 3 of them } Sigma Rules Given the nature of this malware, Sigma rules do not offer effective detection because it does not generate observable log events or behavioral anomalies in standard monitoring platforms. Incident Response U.S. FCEB Agencies CISA requires U.S. FCEB agencies to: Refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and submit it through CISA’s Malware Next Generation platform. Report the submission immediately via CISA’s 24/7 Operations Center (contact@cisa.dhs.gov, 1-844-Say-CISA [1-844-729-2472], or CISA’s Incident Reporting System). Identify the activity is related to FIRESTARTER. After incident intake, CISA will provide guidance on next steps. If compromise is confirmed, this may include instructions to physically unplug the device from power to remove FIRESTARTER’s persistence. Organizations should not unplug the device unless directed to do so by CISA. Other U.S. Organizations CISA recommends organizations take the following actions: Although applicable to U.S. FCEB agencies, refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and deploy the provided YARA rules. U.S. organizations can submit core dumps through CISA’s Malware Next Generation platform. If the core dump indicates the presence of FIRESTARTER malware, proceed with steps 3 and 4 below; additionally, activate internal incident response plans to assess potential lateral movement and impact: Unplug the device from all power sources—CISA assesses this is the only method to remove FIRESTARTER’s persistence from a device—then conduct the following steps: Locate the physical device. Unplug the physical device from its power source while the device is still powered on. Note: It is not sufficient to power the device off or reboot it. The device must be entirely removed from all power sources, including duplicate power sources created for redundancy. Leave the device fully disconnected from any power source for one minute. Reconnect the device to its power source and allow it to reboot. Promptly report any detection of FIRESTARTER malware to CISA. U.S. organizations can report to CISA’s 24/7 Operations Center (contact@cisa.dhs.gov, 1-844-Say-CISA [1-844-729-2472], or CISA’s Incident Reporting System). Requests for assistance can also be submitted to CISA via this reporting channel. U.K. Organizations The NCSC recommends U.K. organizations take the following actions: Refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and deploy the provided YARA rules. If FIRESTARTER is detected, report an incident to the NCSC via https://report.ncsc.gov.uk. After reporting an incident, the NCSC will provide guidance on next steps. If compromise is confirmed, this may include instructions to physically unplug the device from power to remove FIRESTARTER’s persistence. Organizations should not unplug the device unless directed to do so by the NCSC. Mitigations CISA and the NCSC recommend all organizations implement the mitigations below to improve cybersecurity posture on the basis of the threat actors’ activity. These mitigations align with the Cross-Sector Cybersecurity Performance Goals 2.0 (CPG 2.0) developed by CISA and the National Institute of Standards and Technology (NIST). The CPGs provide a minimum set of practices and protections recommended for all organizations. CISA and NIST based the CPGs on existing cybersecurity frameworks and guidance to protect against the most common and impactful threats, tactics, techniques, and procedures. Visit CISA’s CPG 2.0 webpage for more information on the CPGs, including additional recommended baseline protections. Maintain all systems and software with the latest security patches, prioritizing expedited remediation of vulnerabilities listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog [CPG 2.B]. At the time of ED 25-03’s release (Sept. 25, 2025), available patches did not specifically remediate FIRESTARTER; although patching mitigated initial access, it did not eliminate this persistence mechanism. For additional information on software updates that prevent FIRESTARTER’s persistence and for remediation guidance, refer to Cisco’s Security Advisory. Inventory all network edge devices [CPG 2.A], with a specific focus on Cisco devices. Monitor these devices for any suspicious network connections that correlate with the activity described in this report. Monitor and audit activity for all accounts with elevated privileges, including network administrators and service accounts, to detect unauthorized use or anomalous behavior. For example, track and review commands executed by these accounts, and promptly investigate any suspicious activity identified. Apply the principle of least privilege and restrict service accounts to needed permissions only [CPG 3.H]. Regularly rotate passwords for privileged accounts (such as network administrators) and service accounts. Routine password changes invalidate credentials that threat actors may have compromised, forcing them to reestablish access and increasing the likelihood of detection or disruption. While not specific to FIRESTARTER, modernize administrative access controls by implementing TACACS+ over TLS 1.3. This approach encrypts device administration Authentication, Authorization, and Accounting traffic, safeguards administrator and service account credentials, and reduces the risk of interception [CPG 3.K]. See Cisco’s blog, Modernizing TACACS+: Why Full-Session Encryption Matters More Than Ever. Disclaimer CISA and the NCSC do not endorse any commercial entity, product, company, or service, including any entities, products, companies, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favor by CISA or the NCSC. Acknowledgements Cisco contributed to this Malware Analysis Report. Version History April 23, 2026: Initial version. Appendix A: MITRE ATT&CK Techniques See Table 2 through Table 7 all referenced threat actor tactics and techniques in this advisory. For assistance with mapping malicious cyber activity to the MITRE ATT&CK framework, see CISA and MITRE ATT&CK’s Best Practices for MITRE ATT&CK Mapping and CISA’s Decider Tool. Table 2. Initial Access Technique Title ID Use Exploit Public-Facing Application T1190 The APT actors gained access to the victim’s Cisco Firepower device, likely by exploiting CVE-2025-20333 and/or CVE-2025-20362. Table 3. Execution Technique Title ID Use Command and Scripting Interpreter T1059 FIRESTARTER uses a special function to run shell commands that create /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST if it is missing. FIRESTARTER runs callback commands to manage its files. Table 4. Persistence Technique Title ID Use Create or Modify System Process T1543 FIRESTARTER invokes mprotect to enable execution of newly injected code. Event Triggered Execution: Unix Shell Configuration Modification T1546.004 FIRESTARTER registers a callback function that is automatically triggered when the program receives any of the following termination-related signals: SIGTERM, SIGINT, SIGQUIT, SIGABRT, SIGHUP, or SIGTSTP. Boot or Logon Autostart Execution T1547 Persistence is maintained by modifying a boot-time configuration/mount script so FIRESTARTER runs on startup. External Remote Services T1133 The APT actors used LINE VIPER to establish illegitimate VPN sessions. Valid Accounts T1078 The APT actors used valid user accounts for their illegitimate VPN sessions (the user accounts belonged to former employees). Table 5. Defense Evasion Technique Title ID Use File and Directory Permissions Modification T1222 FIRESTARTER creates the /opt/cisco/platform/logs/var/log/ directory with full read/write/execute permissions. FIRESTARTER uses chown and chmod to modify file permissions. Hide Artifacts: Hidden Users T1564 FIRESTARTER redirects standard error (stderr) messages to /dev/null and hides them from the console. Indicator Removal on Host: File Deletion T1070.004 FIRESTARTER deletes the following files: CSP_MOUNT_LIST, CSP_MOUNT_LIST.tmp, and /usr/bin/lina_cs. Indicator Removal on Host: Timestomp T1070.006 FIRESTARTER uses touch -r to copy timestamps from original files to modified and temporary ones, explicitly to match the original. Masquerading: Match Legitimate Resource Name or Location T1036.005 FIRESTARTER accesses its own binary located at /usr/bin/lina_cs on the victim device. Process Injection T1055 FIRESTARTER injects shellcode into a library’s code section before the start of the text segment. Table 6. Discovery Technique Title ID Use Process Discovery T1057 FIRESTARTER enumerates LINA’s virtual memory map to locate the private read-write (rw-p) segment associated with lina. System Information Discovery T1082 The APT actors used LINE VIPER to access Cisco Firepower device configuration elements, including administrative credentials, certificates, and private keys. Table 7. Command and Control Technique Title ID Use Remote Access Tools T1219 FIRESTARTER is a Linux ELF designed to execute on Cisco Firepower and Secure Firewall devices, serving as a C2 channel for remote access and control.
· CISA Cybersecurity Advisory

Yadea T5 Electric Bicycle

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker being able to unlock and start the bicycle, leading to vehicle theft. The following versions of Yadea T5 Electric Bicycle are affected: T5 Electric Bicycle vers:all/* (CVE-2025-70994) CVSS Vendor Equipment Vulnerabilities v3 7.3 Yadea Yadea T5 Electric Bicycle Weak Authentication Background Critical Infrastructure Sectors:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker being able to unlock and start the bicycle, leading to vehicle theft. The following versions of Yadea T5 Electric Bicycle are affected: T5 Electric Bicycle vers:all/* (CVE-2025-70994) CVSS Vendor Equipment Vulnerabilities v3 7.3 Yadea Yadea T5 Electric Bicycle Weak Authentication Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-70994 Yadea T5 Electric Bicycles have a weak authentication mechanism which is vulnerable to signal forgery after a local attacker intercepts any legitimate key fob transmissions. View CVE Details Affected Products Yadea T5 Electric Bicycle Vendor: Yadea Product Version: Yadea T5 Electric Bicycle: vers:all/* Product Status: known_affected Remediations Mitigation Yadea did not respond to CISA's attempts at coordination. Users of Yadea T5 Electric Bicycles are encouraged to keep their systems up to date and lock their property securely with external mechanisms. Users can contact Yadea at https://yadea.com/contact-us. https://yadea.com/contact-us Relevant CWE: CWE-1390 Weak Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H Acknowledgments Ashen Chathuranga reported this vulnerability to MITRE and CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Defending Against China-Nexus Covert Networks of Compromised Devices

Defending against china-nexus covert networks of compromised devices executive summary Defending against China-nexus covert networks of compromised devices Explaining the widespread shift in tactics, techniques and procedures (TTPs) towards networks of compromised infrastructure, and how to defend against it Summary With support from the UK Cyber League, this advisory has been jointly released by the National Cyber…
Read full source summary
Defending against china-nexus covert networks of compromised devices executive summary Defending against China-nexus covert networks of compromised devices Explaining the widespread shift in tactics, techniques and procedures (TTPs) towards networks of compromised infrastructure, and how to defend against it Summary With support from the UK Cyber League, this advisory has been jointly released by the National Cyber Security Centre (NCSC-UK) and international partners: Australian Signals Directorate’s (ASD’s) Australian Cyber Security Centre (ACSC) Communications Security Establishment Canada’s (CSE’s) Canadian Centre for Cyber Security (Cyber Centre) Germany Federal Office for the Protection of the Constitution - Bundesamt für Verfassungsschutz (BfV) Germany Federal Intelligence Service – Bundesnachrichtendienst (BND) Germany Federal Office for Information Security - Bundesamt für Sicherheit in der Informationstechnik (BSI) Japan National Cybersecurity Office (NCO) - 国家サイバー統括室 Netherlands General Intelligence and Security Service - Algemene Inlichtingen- en Veiligheidsdienst (AIVD) Netherlands Defence Intelligence and Security Service - Militaire Inlichtingen- en Veiligheidsdienst (MIVD) New Zealand National Cyber Security Centre (NCSC-NZ) Spain National Cryptologic Centre – Centro Criptológico Nacional (CCN) Sweden National Cyber Security Centre - Nationellt cybersäkerhetscenter (NCSC-SE) United States Cybersecurity and Infrastructure Security Agency (CISA) United States Department of Defense Cyber Crime Center (DC3) United States Federal Bureau of Investigation (FBI) United States National Security Agency (NSA) Its purpose is to provide network defenders with the tools needed to defend against China-nexus cyber actors and their tactic of using large scale networks of compromised devices (covert networks) to route their cyber activity. Introduction Over the past few years there has been a major shift in the tactics, techniques and procedures (TTPs) used by China-nexus cyber actors, moving away from the use of individually procured infrastructure, and towards the use of externally provisioned, large-scale networks of compromised devices. The NCSC believes that the majority of China-nexus threat actors are using these networks (hereafter “covert networks”), that multiple covert networks have been created and are being constantly updated, and that a single covert network could be being used by multiple actors. These networks are mainly made up of compromised Small Office Home Office (SOHO) routers, as well as Internet of Things (IoT) and smart devices. Anyone who is a target of China-nexus cyber actors may be impacted by the use of covert networks. They have been used by Chinese state-sponsored actors Volt Typhoon to pre-position offensive cyber capabilities on critical national infrastructure. The group Flax Typhoon used a different covert network of compromised infrastructure to conduct cyber espionage. The use of covert networks of compromised devices - also known as botnets - to facilitate malicious cyber activity is not new, but China-nexus cyber actors are now using them strategically, and at scale. This advisory describes the typical makeup of a covert network and what they are being used for. It also includes protective advice for organizations being targeted by cyber activity using a covert network as an access vector. Covert Networks Covert networks are used to connect across the internet in a low-cost, low-risk, deniable way, disguising the origin and attribution of malicious activity. Actors have been observed using them for each phase of their Cyber Kill Chains, from performing scans as part of reconnaissance, to the delivery of malware, communicating with said malware, and exfiltrating stolen data from a victim. They can also be used for general deniable internet browsing, allowing threat actors to research exploitation techniques, new TTPs, and their victims without attribution. Some covert networks are also used by legitimate customers to browse the internet, making it challenging to attribute malicious activity. There is evidence that covert networks used by China-nexus actors are created and maintained by Chinese information security companies. A network known to network defenders as Raptor Train, which in 2024 infected more than 200,000 devices worldwide, was controlled and managed by the Chinese company, Integrity Technology Group. This company was also assessed by the FBI to be responsible for the computer intrusion activities attributed to China-based hackers known as Flax Typhoon. Botnet operations represent a significant threat to the UK by exploiting vulnerabilities in everyday internet-connected devices with the potential to carry out large-scale cyber attacks – NCSC Director of Operations, Paul Chichester Covert networks mostly consist of compromised SOHO routers, but they also pull in any vulnerable device they can exploit at scale. Raptor Train was made up of thousands of SOHO routers and IoT devices, such as web cameras and video recorders, as well as firewalls and Network Attached Storage (NAS) devices. The KV Botnet used by Volt Typhoon was mainly made up of vulnerable Cisco and NetGear routers. The edge devices were vulnerable because they were “end of life” – out of date and no longer receiving updates or security patches by their manufacturers. The cyber security industry has been aware of examples of these networks for some time and has publicly reported on the widespread scale of the threat and its implications. Mandiant Intelligence produced a public blog in May 2024 talking about covert networks in which they highlighted a key issue for defenders – indicator of compromise (IOC) Extinction. If a particular threat group could now come from one of many covert networks, each with potentially hundreds of thousands of endpoints, and each used by multiple threat actors, old network defense paradigms of static malicious IP block lists will be less effective. This is compounded by the dynamic nature of these networks where new nodes will be added as old devices are patched or removed from use. Typical Network Topology The number of covert networks used by China-nexus cyber actors is large, with new networks regularly developed and deployed. The existing covert networks change too, either because of defensive or legal action, or simply as a result of software updates and new exploits being used to target different technologies for incorporation into the network. Because of this, a description of all known covert networks in detail, including how they are constructed and how they communicate, would immediately be out of date – and for most network defenders would not be practically useful. However, most covert networks of compromised devices use the same basic set up. Understanding this generalized structure can aid researchers and defenders by helping them to understand which part of a network they may have found, and how to defend against it. A diagram illustrating the basic setup of a covert network. The diagram above illustrates the basic setup of a covert network, where typically an actor will connect to the network via an on-ramp or entry node. Their traffic will be forwarded through multiple compromised devices, used as traversal nodes, before exiting the network from an exit node, usually in the same geographic region as the target. Protective Advice Defending from attackers using covert networks is not straightforward, and defensive tactics will be different based on the levels of resource and the nature of the target organization. General advice for good cyber security practice should be followed, and some key messages can be found in the appendix of this advisory. The following advice is specifically tailored to steps which can be taken to combat the risk of attacks coming from large, dynamic networks of compromised devices. Further guidance for all organizations facing cyber security threats is available on the NCSC website. This guidance should be considered alongside all applicable laws and regulations of the UK and co-sealing countries relating to the security of networks and data. It will be each organization’s responsibility to ensure compliance with any such laws and regulations. Organizations should note that following the recommended actions set out below will not remove all risks. All organizations The NCSC recommends the following steps for all affected organizations to either take themselves, or ask their managed service and/or security providers to investigate for them: Map and understand network edge devices, developing a clear understanding of organizational assets and what should be connecting to them. Baseline normal connections, especially to corporate virtual private networks (VPNs) or other similar services. Would you expect connections from consumer broadband ranges? Leverage available dynamic threat feeds which include covert network infrastructure. Implement multifactor authentication for remote connections. Smaller organizations should consider creating and actioning a free NCSC Cyber Action Toolkit. Larger or more at-risk organizations Some more comprehensive measures may be appropriate if the risk to an organization is high enough, to be conducted either in-house or through a security provider: Apply IP address allow lists rather than deny lists for connections to corporate VPNs for remote workers. Use geographic allow lists or profile incoming connections based on operating system, time zones, and/or organization specific system configuration settings. Implement zero trust policies for connections. Enforce machine certificates for Secure Sockets Layer (SSL) connections. Reduce the internet-facing presence of the IT estate. Investigate machine learning techniques to profile normal network edge activity to detect and block anomalies. The NCSC's Cyber Essentials can help protect organizations of all sizes. Largest or most at-risk organizations If Advanced Persistent Threat (APT) tracking is part of an organization’s in-house capability, or if it is part of the service provided by a security vendor, consider tracking China-nexus covert networks as APTs in their own right. Active hunting – look for connections from IP addresses likely to be part of a covert network of compromised devices, for instance those hosting SOHO routers or IoT devices. Track and map covert networks reported by industry or government by looking at banners and certificates. Use threat reporting and threat feeds to create and implement dynamic blocklists and create alert rules to detect incoming threats. Consider using NetFlow feeds to look upstream and map covert networks to find new nodes. The NCSC Cyber Assessment Framework provides guidance for organizations under the highest levels of threat, including those operating essential services, in sectors such as energy, healthcare, transport, digital infrastructure and government. MITRE ATT&CK® This advisory has been compiled with respect to the MITRE ATT&CK® framework, a globally accessible knowledge base of adversary tactics and techniques based on real-world observations. Tactic ID Technique Procedure Resource Development T1584.005 Compromise Infrastructure: Botnet Botnets are used as core components of covert networks Resource Development T1584.008 Compromise Infrastructure: Network Devices Devices are compromised and added to botnets Resource Development T1583.003 Acquire Infrastructure: Virtual Private Server Virtual private servers (VPS) are used in covert networks, typically as on-ramps Command and Control T1090.003 Proxy: Multi-hop Proxy Used by China-nexus cyber actors to route traffic Appendix: Cyber Security Best Practices In addition to the protective advice outlined in this advisory, a number of cyber security best practices will also be useful in defending against the activity described in this advisory. Protect your devices and networks by keeping them up to date: use the latest supported versions, apply security updates promptly, use antivirus and scan regularly to guard against known malware threats. See NCSC Guidance: https://www.ncsc.gov.uk/collection/device-security-guidance/policies-and-settings/antivirus-and-other-security-software Prevent and detect lateral movement in your organization’s networks. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/preventing-lateral-movement Implement architectural controls for network segregation. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/10-steps-network-security Set up a security monitoring capability so you are collecting the data that will be needed to analyze network intrusions. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/introduction-logging-security-purposes and https://www.ncsc.gov.uk/information/logging-made-easy Use modern systems and software. These have better security built-in. If you cannot move off out-of-date platforms and applications straight away, there are short term steps you can take to improve your position. See NCSC Guidance: https://www.ncsc.gov.uk/collection/mobile-device-guidance/managing-the-risks-from-obsolete-products Restrict intruders' ability to move freely around your systems and networks. Pay particular attention to potentially vulnerable entry points such as third-party systems with onward access to your core network. During an incident, disable remote access from third-party systems until you are sure they are clean. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/preventing-lateral-movement and https://www.ncsc.gov.uk/guidance/assessing-supply-chain-security. Deploy a host-based intrusion detection system. A variety of products are available, free and paid-for, to suit different needs and budgets. Further information: Invest in preventing malware-based attacks across various scenarios. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/mitigating-malware-and-ransomware-attacks Disclaimer This report draws on information derived from NCSC and industry sources. Any NCSC findings and recommendations made have not been provided with the intention of avoiding all risks and following the recommendations will not remove all such risk. Ownership of information risks remains with the relevant system owner at all times. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by co-sealers. UK readers should refer to the NCSC website for information about NCSC assured services. This information is exempt under the Freedom of Information Act 2000 (FOIA) and may be exempt under other UK information legislation. Refer any FOIA queries to ncscinfoleg@ncsc.gov.uk. All material is UK Crown Copyright ©
· CISA Cybersecurity Advisory

Milesight Cameras

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed or allow remote code execution. The following versions of Milesight Cameras are affected: MS-Cxx63-PD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx64-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed or allow remote code execution. The following versions of Milesight Cameras are affected: MS-Cxx63-PD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx64-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx73-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx75-xxPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx83-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx74-PA <=3x.8.0.3-r11 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C8477-HPG1 <=63.8.0.4-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C8477-PC <=48.8.0.4-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5321-FPE <=62.8.0.4-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx62-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx52-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxGPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx61-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx67-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx71-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx41-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx76-PE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx65-PE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx62-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx31-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx68-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx72-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-NxE <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxC <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxE <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxG <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxH <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxT <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PMC8266-FPE <=PO_61.8.0.4_LPR (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PMC8266-FGPE <=PO_61.8.0.4_LPR (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PM3322-E <=PI_61.8.0.3_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-RFIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-RFIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIWG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIWG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5510-GVH <=T_47.8.0.4_LPR-r7 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5510-GH <=T_47.8.0.4_LPR-r6 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5511-GVH <=T_47.8.0.4_LPR-r6 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2966-X12TPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12PE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4PE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2966-X12TVPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RVPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12VPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4VPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4441-X36RPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4441-X36RE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RWE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4WE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2964-RFLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2972-RFLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-RFLWPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TGPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2841-X36TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2841-X36TPC/W <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2867-X5TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2961-X12TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-FPC/P <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-X12RLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-X12RLVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5366-X12LPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5366-X12LVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5361-X12LPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxxGOPC <=45.8.0.2-AIoT-r4 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) SC211 <=C_21.1.0.8-r4 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) SP111 <=52.8.0.4-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-RFIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-RFIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-FIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-FIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) CVSS Vendor Equipment Vulnerabilities v3 9.8 Milesight Milesight Cameras Authorization Bypass Through User-Controlled Key, Use of Hard-coded Credentials, Use of Hard-coded Cryptographic Key, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-28747 A weak key generation vulnerability exists in specific firmware versions of Milesight AIOT cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-27785 Specific firmware versions of Milesight AIOT camera firmware contain hard-coded credentials. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32644 Specific firmware versions of Milesight AIOT cameras use SSL certificates with default private keys. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32649 A command injection vulnerability exists in the web server of specific firmware versions of Milesight cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H CVE-2026-20766 An out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC: 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Souvik Kandar reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SpiceJet Online Booking System

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information. The following versions of SpiceJet Online Booking System are affected: Online Booking System vers:all/* (CVE-2026-6375, CVE-2026-6376) CVSS Vendor Equipment Vulnerabilities v3 7.5 SpiceJet SpiceJet Online Booking System Authorization Bypass Through User-Controlled Key, Missing Authentication…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information. The following versions of SpiceJet Online Booking System are affected: Online Booking System vers:all/* (CVE-2026-6375, CVE-2026-6376) CVSS Vendor Equipment Vulnerabilities v3 7.5 SpiceJet SpiceJet Online Booking System Authorization Bypass Through User-Controlled Key, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-6375 A vulnerability in SpiceJet's booking API allows unauthenticated users to query passenger name records (PNRs) without any access controls. Because PNR identifiers follow a predictable pattern, an attacker could systematically enumerate valid records and obtain associated passenger names. This flaw stems from missing authorization checks on an endpoint intended for authenticated profile access. View CVE Details Affected Products SpiceJet Online Booking System Vendor: SpiceJet Product Version: SpiceJet Online Booking System: vers:all/* Product Status: known_affected Remediations Mitigation SpiceJet did not respond to CISA's requests to coordinate. Users are encouraged to reach out to SpiceJet for more information: https://corporate.spicejet.com/contactus.aspx https://corporate.spicejet.com/contactus.aspx Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-6376 A weakness in SpiceJet's public booking retrieval page permits full passenger booking details to be accessed using only a PNR and last name, with no authentication or verification mechanisms. This results in exposure of extensive personal, travel, and booking metadata to any unauthenticated user who can obtain or guess those basic inputs. The issue arises from improper access control on a sensitive data retrieval function. View CVE Details Affected Products SpiceJet Online Booking System Vendor: SpiceJet Product Version: SpiceJet Online Booking System: vers:all/* Product Status: known_affected Remediations Mitigation SpiceJet did not respond to CISA's requests to coordinate. Users are encouraged to reach out to SpiceJet for more information: https://corporate.spicejet.com/contactus.aspx https://corporate.spicejet.com/contactus.aspx Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Owais Shaikh reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Intrado 911 Emergency Gateway (EGW)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read, modify, or delete files. The following versions of Intrado 911 Emergency Gateway (EGW) are affected: Emergency Gateway 7.x (CVE-2026-6074) Emergency Gateway 6.x (CVE-2026-6074) Emergency Gateway 5.x (CVE-2026-6074) CVSS Vendor Equipment Vulnerabilities v3 9.8 Intrado Intrado 911 Emergency Gateway (EGW) Path Traversal:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read, modify, or delete files. The following versions of Intrado 911 Emergency Gateway (EGW) are affected: Emergency Gateway 7.x (CVE-2026-6074) Emergency Gateway 6.x (CVE-2026-6074) Emergency Gateway 5.x (CVE-2026-6074) CVSS Vendor Equipment Vulnerabilities v3 9.8 Intrado Intrado 911 Emergency Gateway (EGW) Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Emergency Services Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6074 A path traversal condition in Intrado 911 Emergency Gateway could allow an attacker with existing network access the ability to access the EGW management interface without authentication. Successful exploitation of this vulnerability could allow a user to read, modify, or delete files. View CVE Details Affected Products Intrado 911 Emergency Gateway (EGW) Vendor: Intrado Product Version: Intrado Emergency Gateway: 7.x, Intrado Emergency Gateway: 6.x, Intrado Emergency Gateway: 5.x Product Status: known_affected Remediations Mitigation Intrado developed and released a software update on March 2nd, 2026, that addresses this issue and has contacted customers to coordinate applying the patch. Mitigation If you have questions, contact Intrado E911 Support: E911Support@intrado.com mailto:E911Support@intrado.com Relevant CWE: CWE-35 Path Traversal: '.../...//' Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments An anonymous source reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33825 Microsoft Defender Insufficient Granularity of Access Control Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33825 Microsoft Defender Insufficient Granularity of Access Control Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Siemens SINEC NMS

View CSAF Summary SINEC NMS before V4.0 SP3 contains an Authorization Bypass vulnerability that could allow an attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment…
Read full source summary
View CSAF Summary SINEC NMS before V4.0 SP3 contains an Authorization Bypass vulnerability that could allow an attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens SINEC NMS Authorization Bypass Through User-Controlled Key Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25654 Affected products do not properly validate user authorization when processing password reset requests. This could allow an authenticated remote attacker to bypass authorization checks, leading to the ability to reset the password of any arbitrary user account. View CVE Details Affected Products Siemens SINEC NMS Vendor: Siemens Product Version: SINEC NMS Product Status: known_affected Remediations Mitigation Limit network access to trusted users and systems only Vendor fix Update to V4.0 SP3 or later version https://support.industry.siemens.com/cs/ww/en/view/110000760/ Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-605717 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-605717 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens TPM 2.0

View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to perform an out-of-bound read, potentially leading to information disclosure or denial of service of the TPM. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes…
Read full source summary
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to perform an out-of-bound read, potentially leading to information disclosure or denial of service of the TPM. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens TPM 2.0 are affected: SIMATIC CN 4100 vers:all/* (CVE-2025-2884) SIMATIC Field PG M5 vers:all/* (CVE-2025-2884) SIMATIC Field PG M6 vers:all/* (CVE-2025-2884) SIMATIC IPC BX-32A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC BX-39A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC BX-56A vers:intdot/<32.01.09 (CVE-2025-2884) SIMATIC IPC BX-59A vers:intdot/<32.01.09 (CVE-2025-2884) SIMATIC IPC MD-57A vers:intdot/<30.01.10 (CVE-2025-2884) SIMATIC IPC PX-32A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC PX-39A vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC PX-39A PRO vers:intdot/<29.01.09 (CVE-2025-2884) SIMATIC IPC RW-528A vers:intdot/<34.01.02 (CVE-2025-2884) SIMATIC IPC RW-548A vers:intdot/<34.01.02 (CVE-2025-2884) SIMATIC IPC227E vers:all/* (CVE-2025-2884) SIMATIC IPC277E vers:all/* (CVE-2025-2884) SIMATIC IPC427E vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC477E vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC477E PRO vers:intdot/<21.01.20 (CVE-2025-2884) SIMATIC IPC627E vers:all/* (CVE-2025-2884) SIMATIC IPC647E vers:all/* (CVE-2025-2884) SIMATIC IPC677E vers:all/* (CVE-2025-2884) SIMATIC IPC847E vers:all/* (CVE-2025-2884) SIMATIC ITP1000 vers:all/* (CVE-2025-2884) SIPLUS IPC427E vers:intdot/<21.01.20 (CVE-2025-2884) CVSS Vendor Equipment Vulnerabilities v3 6.6 Siemens Siemens TPM 2.0 Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-2884 TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0 View CVE Details Affected Products Siemens TPM 2.0 Vendor: Siemens Product Version: SIMATIC CN 4100, SIMATIC Field PG M5, SIMATIC Field PG M6, SIMATIC IPC BX-32A, SIMATIC IPC BX-39A, SIMATIC IPC BX-56A, SIMATIC IPC BX-59A, SIMATIC IPC MD-57A, SIMATIC IPC PX-32A, SIMATIC IPC PX-39A, SIMATIC IPC PX-39A PRO, SIMATIC IPC RW-528A, SIMATIC IPC RW-548A, SIMATIC IPC227E, SIMATIC IPC277E, SIMATIC IPC427E, SIMATIC IPC477E, SIMATIC IPC477E PRO, SIMATIC IPC627E, SIMATIC IPC647E, SIMATIC IPC677E, SIMATIC IPC847E, SIMATIC ITP1000, SIPLUS IPC427E Product Status: known_affected Remediations No fix planned Currently no fix is planned None available Currently no fix is available Vendor fix Update to V21.01.20 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V29.01.09 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V30.01.10 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V32.01.09 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Vendor fix Update to V34.01.02 or later version https://support.industry.siemens.com/cs/ww/en/view/109763408/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.6 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-628843 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-628843 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Industrial Edge Management

View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens…
Read full source summary
View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Pro V1 vers:intdot/>=1.7.6|<1.15.17 (CVE-2026-33892) Industrial Edge Management Pro V2 vers:intdot/>=2.0.0|<2.1.1 (CVE-2026-33892) Industrial Edge Management Virtual vers:intdot/>=2.2.0|<2.8.0 (CVE-2026-33892) CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens Industrial Edge Management Authentication Bypass by Primary Weakness Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-33892 Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected. View CVE Details Affected Products Siemens Industrial Edge Management Vendor: Siemens Product Version: Industrial Edge Management Pro V1, Industrial Edge Management Pro V2, Industrial Edge Management Virtual Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.15.17 or later version https://iehub.eu1.edge.siemens.cloud/ Vendor fix Update to V2.1.1 or later version https://iehub.eu1.edge.siemens.cloud/ Vendor fix Update to V2.8.0 or later version https://iehub.eu1.edge.siemens.cloud/ Relevant CWE: CWE-305 Authentication Bypass by Primary Weakness Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-609469 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-609469 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SINEC NMS

View CSAF Summary Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following…
Read full source summary
View CSAF Summary Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment Vulnerabilities v3 7.3 Siemens Siemens SINEC NMS Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-24032 The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. (ZDI-CAN-27564) View CVE Details Affected Products Siemens SINEC NMS Vendor: Siemens Product Version: SINEC NMS Product Status: known_affected Remediations Vendor fix Update to V4.0 SP3 or later version https://support.industry.siemens.com/cs/ww/en/view/110000760/ Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-801704 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-801704 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SenseLive X3050

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device. The following versions of SenseLive X3050 are affected: X3050 V1.523 (CVE-2026-40630, CVE-2026-25720, CVE-2026-35503, CVE-2026-39462, CVE-2026-27843, CVE-2026-40431, CVE-2026-40623, CVE-2026-27841, CVE-2026-40620, CVE-2026-35064, CVE-2026-25775) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to take complete control of the device. The following versions of SenseLive X3050 are affected: X3050 V1.523 (CVE-2026-40630, CVE-2026-25720, CVE-2026-35503, CVE-2026-39462, CVE-2026-27843, CVE-2026-40431, CVE-2026-40623, CVE-2026-27841, CVE-2026-40620, CVE-2026-35064, CVE-2026-25775) CVSS Vendor Equipment Vulnerabilities v3 9.8 SenseLive SenseLive X3050 Authentication Bypass Using an Alternate Path or Channel, Insufficient Session Expiration, Use of Hard-coded Credentials, Insufficiently Protected Credentials, Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information, Missing Authorization, Cross-Site Request Forgery (CSRF) Background Critical Infrastructure Sectors: Critical Manufacturing, Water and Wastewater, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-40630 A vulnerability in the X3050's web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25720 A vulnerability exists in the X3050's web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N CVE-2026-35503 A vulnerability in the X3050's web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-39462 A vulnerability exists in the X3050's web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-27843 A vulnerability exists in the X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-40431 A vulnerability exists in the X3050's web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-40623 A vulnerability in the X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2026-27841 A vulnerability in the X3050's web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user's browser to submit unauthorized configuration requests to the device. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-352 Cross-Site Request Forgery (CSRF) Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H CVE-2026-40620 A vulnerability in the X3050's embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-35064 A vulnerability in the X3050's management ecosystem allows unauthenticated discovery of deployed units through the vendor's management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-25775 A vulnerability in X3050's remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware. View CVE Details Affected Products SenseLive X3050 Vendor: SenseLive Product Version: SenseLive X3050: V1.523 Product Status: known_affected Remediations Mitigation SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact https://senselive.io/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Jithin Nambiar J reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Zero Motorcycles Firmware

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to pair via Bluetooth with a motorcycle, gaining unauthorized access to all Bluetooth functions, including changing the firmware. The following versions of Zero Motorcycles Firmware are affected: Zero Motorcycles firmware <=44 (CVE-2026-1354) CVSS Vendor Equipment Vulnerabilities v3 6.4 Zero Motorcycles Zero Motorcycles Firmware…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to pair via Bluetooth with a motorcycle, gaining unauthorized access to all Bluetooth functions, including changing the firmware. The following versions of Zero Motorcycles Firmware are affected: Zero Motorcycles firmware <=44 (CVE-2026-1354) CVSS Vendor Equipment Vulnerabilities v3 6.4 Zero Motorcycles Zero Motorcycles Firmware Key Exchange without Entity Authentication Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1354 Zero Motorcycles firmware versions 44 and prior enable an attacker to forcibly pair a device with the motorcycle via Bluetooth. Once paired, an attacker can utilize over-the-air firmware updating functionality to potentially upload malicious firmware to the motorcycle. The motorcycle must first be in Bluetooth pairing mode, and the attacker must be in proximity of the vehicle and understand the full pairing process, to be able to pair their device with the vehicle. The attacker's device must remain paired with and in proximity of the motorcycle for the entire duration of the firmware update. View CVE Details Affected Products Zero Motorcycles Firmware Vendor: Zero Motorcycles Product Version: Zero Motorcycles Zero Motorcycles firmware: <=44 Product Status: known_affected Remediations Mitigation Zero Motorcycles has investigated this report and cautions users to pair their mobile device to their vehicle in a safe location where they can be sure no one else will try to pair at the same time. Once initiated, complete the full pairing process and confirm it is successful. Store physical keys in a secure location and do not leave the bike unattended with the key in the "ON" position. Zero Motorcycles plans to address this issue in a firmware update scheduled for release in May 2026. Update the firmware to the latest available version. Relevant CWE: CWE-322 Key Exchange without Entity Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H Acknowledgments Persephone Karnstein of Bureau Veritas Cybersecurity North America reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Analytics Toolkit

View CSAF Summary Multiple Siemens applications are affected by improper certificate validation in Siemens Analytics Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Analytics Toolkit are affected: Siemens Software Center…
Read full source summary
View CSAF Summary Multiple Siemens applications are affected by improper certificate validation in Siemens Analytics Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Analytics Toolkit are affected: Siemens Software Center vers:intdot/<3.5.8.2 (CVE-2025-40745) Simcenter 3D vers:intdot/<2506.6000 (CVE-2025-40745) Simcenter Femap vers:intdot/<2506.0002 (CVE-2025-40745) Simcenter STAR-CCM+ vers:intdot/<2602 (CVE-2025-40745) Solid Edge SE2025 Solid Edge SE2026 Tecnomatix Plant Simulation vers:intdot/<2504.0008 (CVE-2025-40745) CVSS Vendor Equipment Vulnerabilities v3 3.7 Siemens Siemens Analytics Toolkit Improper Certificate Validation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40745 Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. View CVE Details Affected Products Siemens Analytics Toolkit Vendor: Siemens Product Version: Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Solid Edge SE2025, Solid Edge SE2026, Tecnomatix Plant Simulation Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 13 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 04 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V2504.0008 or later version https://support.sw.siemens.com/product/297028302/ Vendor fix Update to V2506.0002 or later version https://support.sw.siemens.com/product/275652363/ Vendor fix Update to V2506.6000 or later version https://support.sw.siemens.com/product/289054037/ Vendor fix Update to V2602 or later version https://support.sw.siemens.com/product/226870983/ Vendor fix Update to V3.5.8.2 or later version https://www.sw.siemens.com/en-US/siemens-software-center/ Relevant CWE: CWE-295 Improper Certificate Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-981622 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-981622 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary

View CSAF Summary RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) contains a vulnerability that could allow an attacker to escalate their own privileges. Siemens has released a new version for RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary are affected: RUGGEDCOM…
Read full source summary
View CSAF Summary RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) contains a vulnerability that could allow an attacker to escalate their own privileges. Siemens has released a new version for RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary are affected: RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) vers:intdot/<5.8 (CVE-2026-27668) CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary Incorrect Privilege Assignment Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-27668 User Administrators are allowed to administer groups they belong to. This could allow an authenticated User Administrator to escalate their own privileges and grant themselves access to any device group at any access level. View CVE Details Affected Products Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary Vendor: Siemens Product Version: RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) Product Status: known_affected Remediations Vendor fix Update to V5.8 or later version https://support.industry.siemens.com/cs/ww/en/view/110000841/ Relevant CWE: CWE-266 Incorrect Privilege Assignment Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-741509 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Publication Date 2026-04-21 2 Initial CISA Republication of Siemens ProductCERT SSA-741509 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Silex Technology SD-330AC and AMC Manager

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, cause a denial-of-service, or configuration information may be altered without authentication. The following versions of Silex Technology SD-330AC and AMC Manager are affected: SD-330AC <=1.42 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, cause a denial-of-service, or configuration information may be altered without authentication. The following versions of Silex Technology SD-330AC and AMC Manager are affected: SD-330AC <=1.42 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965) AMC Manager <=5.0.2 (CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, CVE-2026-32958, CVE-2015-5621, CVE-2026-32959, CVE-2026-32960, CVE-2026-32961, CVE-2026-32962, CVE-2024-24487, CVE-2026-32963, CVE-2026-32964, CVE-2026-32965) CVSS Vendor Equipment Vulnerabilities v3 9.8 Silex Technology Silex Technology SD-330AC and AMC Manager Stack-based Buffer Overflow, Heap-based Buffer Overflow, Missing Authentication for Critical Function, Use of Hard-coded Cryptographic Key, Dependency on Vulnerable Third-Party Component, Use of a Broken or Risky Cryptographic Algorithm, Sensitive Information in Resource Not Removed Before Reuse, Incorrect Privilege Assignment, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of CRLF Sequences ('CRLF Injection'), Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-32955 A Stack-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-32956 A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to execute arbitrary code on the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32957 A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow uploads of arbitrary files to the device without authentication. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2026-32958 A Use of Hard-coded Cryptographic Key vulnerability in Silex Technology SD-330AC and AMC Manager could cause an administrative user to be directed to apply a fake firmware update. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N CVE-2015-5621 The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash). View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2015-5621: Disable SNMP service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-1395 Dependency on Vulnerable Third-Party Component Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-32959 A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to retrieve information via a man-in-the-middle attack. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-32960 A Sensitive Information in Resource Not Removed Before Reuse vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may allow the attacker to login to the device. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-226 Sensitive Information in Resource Not Removed Before Reuse Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N CVE-2026-32961 A Heap-based Buffer Overflow vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to send specially crafted packets that may cause a temporary denial-of-service (DoS) condition. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L CVE-2026-32962 A Missing Authentication for Critical Function vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to alter the device configuration without authentication. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2024-24487 An issue discovered in Silex Technology DS-600 Firmware v.1.4.1 allows a remote attacker to cause a denial of service via crafted UDP packets using the EXEC REBOOT SYSTEM command. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-266 Incorrect Privilege Assignment Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:H CVE-2026-32963 An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to trick a user into accessing a special web page and execute arbitrary script on the user's browser. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32955, CVE-2026-32956, CVE-2026-32957, and CVE-2026-32963: Disable HTTP/HTTPS service. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N CVE-2026-32964 An Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker to inject arbitrary entries into the system configuration. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L CVE-2026-32965 An Initialization of a Resource with an Insecure Default vulnerability in Silex Technology SD-330AC and AMC Manager could allow an attacker using the factory default configuration to configure the device using the null string password. View CVE Details Affected Products Silex Technology SD-330AC and AMC Manager Vendor: Silex Technology Product Version: Silex Technology SD-330AC: <=1.42, Silex Technology AMC Manager: <=5.0.2 Product Status: known_affected Remediations Vendor fix The developer has released the following versions to address this vulnerability: SD-330AC firmware Ver 1.50 or later Vendor fix AMC Manager Ver.5.1.0 or later Mitigation CVE-2026-32958 and CVE-2026-32965: Set a password for the settings web interface. Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/en/2026-001 Mitigation For more information, see Silex Technology's security advisory in English (https://www.silex.jp/support/security-advisories/en/2026-001) or in Japanese (https://www.silex.jp/support/security-advisories/2026-001). https://www.silex.jp/support/security-advisories/2026-001 Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/en/vu/JVNVU94271449/ Mitigation For more information, see JPCERT/CC vulnerability notes in English (https://jvn.jp/en/vu/JVNVU94271449/) or in Japanese (https://jvn.jp/vu/JVNVU94271449/). https://jvn.jp/vu/JVNVU94271449/ Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N Acknowledgments Francesco La Spina of Forescout Technologies reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-21 Date Revision Summary 2026-04-21 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots