Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on May 1, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

ABB AWIN Gateways

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely reboot the device or complete an unauthenticated query to reveal system configuration, including sensitive details. The following versions of ABB AWIN Gateways are affected: ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2 2.0-0 ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2 2.0-1 ABB AWIN…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely reboot the device or complete an unauthenticated query to reveal system configuration, including sensitive details. The following versions of ABB AWIN Gateways are affected: ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2 2.0-0 ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2 2.0-1 ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120 1.2-0 ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120 1.2-1 CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AWIN Gateways Authentication Bypass by Capture-replay, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-13777 An unauthenticated query reveals data. Authentication Bypass due to Improper Session Validation. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13777 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13777 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-294 Authentication Bypass by Capture-replay Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H CVE-2025-13778 An unauthenticated query allows an attacker to remotely reboot the device, potentially causing a denial of service. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13778 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13778 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-13779 An unauthenticated query reveals the system configuration, including sensitive details. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13779 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13779 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H Acknowledgments Fred Alvarez reported these vulnerabilities to ABB Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB 4JNO000329 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Ability OPTIMAX

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass user authentication on OPTIMAX installations that make use of the Azure Active Directory Single-Sign On integration. The following versions of ABB Ability OPTIMAX are affected: ABB Ability OPTIMAX 6.1 vers:all/* ABB Ability OPTIMAX 6.2 vers:all/* ABB Ability OPTIMAX 6.3 <6.3.1-251120 ABB Ability OPTIMAX 6.4…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass user authentication on OPTIMAX installations that make use of the Azure Active Directory Single-Sign On integration. The following versions of ABB Ability OPTIMAX are affected: ABB Ability OPTIMAX 6.1 vers:all/* ABB Ability OPTIMAX 6.2 vers:all/* ABB Ability OPTIMAX 6.3 <6.3.1-251120 ABB Ability OPTIMAX 6.4 <6.4.1-251120 CVSS Vendor Equipment Vulnerabilities v3 8.1 ABB ABB Ability OPTIMAX Incorrect Implementation of Authentication Algorithm Background Critical Infrastructure Sectors: Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-14510 The vulnerability allows an attacker to bypass user authentication on OPTIMAX installations that make use of the Azure Active Directory Single-Sign On integration. View CVE Details Affected Products ABB Ability OPTIMAX Vendor: ABB Product Version: ABB ABB Ability OPTIMAX 6.1: vers:all/*, ABB ABB Ability OPTIMAX 6.2: vers:all/*, ABB ABB Ability OPTIMAX 6.3: <6.3.1-251120, ABB ABB Ability OPTIMAX 6.4: <6.4.1-251120 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: Ability OPTIMAX 6.3 6.3.1-251120 is a fixed version for CVE-2025-14510 Mitigation For more information see the associated ABB PSIRT security advisory 9AKK108472A1331 ABB CYBERSECURITY ADVISORY - PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A1331&LanguageCode=en&DocumentPartId=&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF Version (https://psirt.abb.com/csaf/2026/9akk108472a1331.json). https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A1331&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 9AKK108472A1331 ABB CYBERSECURITY ADVISORY - PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A1331&LanguageCode=en&DocumentPartId=&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF Version (https://psirt.abb.com/csaf/2026/9akk108472a1331.json). https://psirt.abb.com/csaf/2026/9akk108472a1331.json Relevant CWE: CWE-303 Incorrect Implementation of Authentication Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB PSIRT 9AKK108472A1331 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB PCM600

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send specially crafted messages to the system node resulting in execution of arbitrary code. The following versions of ABB PCM600 are affected: PCM600 >=1.5|<=2.13 CVSS Vendor Equipment Vulnerabilities v3 4.4 ABB ABB PCM600 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send specially crafted messages to the system node resulting in execution of arbitrary code. The following versions of ABB PCM600 are affected: PCM600 >=1.5|<=2.13 CVSS Vendor Equipment Vulnerabilities v3 4.4 ABB ABB PCM600 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2018-1002208 A vulnerability exists in the SharpZip.dll included in the product versions listed above. An attacker could exploit vulnerability by providing a specially crafted message to the system node, causing insertion, and running of arbitrary code. View CVE Details Affected Products ABB PCM600 Vendor: ABB Product Version: ABB PCM600: >=1.5|<=2.13 Product Status: known_affected Remediations Vendor fix The problem is corrected in the following product version: ABB Protection and control IED manager PCM600 version 2.14. ABB recommends that customers apply the update at earliest convenience. Vendor fix Note: RE_630 protection relays are not compatible with PCM600 version 2.14. When using earlier PCM600 versions with RE_630, the known vulnerability must be mitigated through system-level defenses. For mitigation guidance, refer to the General Security Recommendations. Vendor fix The following product versions have been fixed: Protection and Control IED manager PCM600 2.14 is a fixed version for CVE-2018-1002208 Mitigation For more information see the associated ABB PSIRT security advisory 2NGA002813 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/2nga002813.json). https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 2NGA002813 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/2nga002813.json). https://psirt.abb.com/csaf/2025/2nga002813.json Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N Acknowledgments ABB PSIRT reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB PSIRT 2NGA002813 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Edgenius Management Portal

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send a specially crafted message to the system node allowing the attacker to install and run arbitrary code, uninstall applications, and modify the configuration of installed applications. The following versions of ABB Edgenius Management Portal are affected: Edgenius Management Portal 3.2.0.0|3.2.1.1 CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send a specially crafted message to the system node allowing the attacker to install and run arbitrary code, uninstall applications, and modify the configuration of installed applications. The following versions of ABB Edgenius Management Portal are affected: Edgenius Management Portal 3.2.0.0|3.2.1.1 CVSS Vendor Equipment Vulnerabilities v3 9.6 ABB ABB Edgenius Management Portal Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-10571 The Edgenius Management Portal in the affected product versions contains a vulnerability that allows authentication to be bypassed. An attacker could exploit the vulnerability by sending a specially crafted message to the system node allowing the attacker to install and run arbitrary code, uninstall in-stalled applications and modify the configuration of installed applications. View CVE Details Affected Products ABB Edgenius Management Portal Vendor: ABB Product Version: ABB Edgenius Management Portal: 3.2.0.0|3.2.1.1 Product Status: known_affected Remediations Vendor fix ABB has prepared an update to fix this vulnerability included in the latest Roll-Up, ABB Ability Edgenius version 3.2.2.0. ABB advises customers to upgrade as soon as possible. Until the upgrade is applied, ABB advises customers to disable the Edgenius Management Portal to mitigate the vulnerability. Vendor fix All affected products: Exploitation requires an attacker to have gained access to the network where Edgenius has been deployed, and while the Edgenius Management Portal is running. Refer to section "General security recommendations" for further advise on how to keep your system secure. Mitigation All affected products: Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workaround. Mitigation The following product versions have been fixed: Ability Edgenius 3.2.2.0 is a fixed version for CVE-2025-10571 Mitigation For more information see the associated ABB PSIRT security advisory 7PAA022088 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA022088&LanguageCode=en&DocumentPartId=&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/7paa022088.json). https://search.abb.com/library/Download.aspx?DocumentID=7PAA022088&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 7PAA022088 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA022088&LanguageCode=en&DocumentPartId=&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/7paa022088.json). https://psirt.abb.com/csaf/2025/7paa022088.json Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.6 CRITICAL CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB PSIRT 7PAA022088 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-41940 WebPros cPanel & WHM and WP2 (WordPress Squared) Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-41940 WebPros cPanel & WHM and WP2 (WordPress Squared) Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

ABB Ability Symphony Plus Engineering

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. The ABB S+ Engineering product versions are affected by vulnerabilities in PostgreSQL version 13.11 and earlier versions. If an attacker gains access to a site’s S+ Client Server network, they could exploit such vulnerabilities by executing arbitrary code and potentially compromising the entire system.…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. The ABB S+ Engineering product versions are affected by vulnerabilities in PostgreSQL version 13.11 and earlier versions. If an attacker gains access to a site’s S+ Client Server network, they could exploit such vulnerabilities by executing arbitrary code and potentially compromising the entire system. The following versions of ABB Ability Symphony Plus Engineering are affected: Ability Symphony Plus 2.2, 2.3, 2.3_RU1, 2.3_RU2, 2.3_RU3, 2.4, 2.4_SP1, 2.4_SP2, 2.4_SP2_RU1 CVSS Vendor Equipment Vulnerabilities v3 8.8 ABB ABB Ability Symphony Plus Engineering Integer Overflow or Wraparound, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Time-of-check Time-of-use (TOCTOU) Race Condition, Privilege Dropping / Lowering Errors Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2023-5869 An attacker running as an authenticated PostgreSQL user can provide crafted data and trigger the integer overflow due to such missing overflow check. This can enable the execution of arbitrary code in the system. View CVE Details Affected Products ABB Ability Symphony Plus Engineering Vendor: ABB Product Version: ABB Ability Symphony Plus S+ Engineering 2.2, ABB Ability Symphony Plus S+ Engineering 2.3, ABB Ability Symphony Plus S+ Engineering 2.3 RU1, ABB Ability Symphony Plus S+ Engineering 2.3 RU2, ABB Ability Symphony Plus S+ Engineering 2.3 RU3, ABB Ability Symphony Plus S+ Engineering 2.4, ABB Ability Symphony Plus S+ Engineering 2.4 SP1, ABB Ability Symphony Plus S+ Engineering 2.4 SP2 Product Status: fixed, known_affected Remediations Vendor fix ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: - Systems using S+ Engineering 2.2 through 2.4 SP2 should upgrade to S+ Engineering 2.4 SP2 RU1 (re-leased in December 2024) or later. - End users who are unable to install one of these updates should immediately look to implement the Mitigation and Workarounds listed below as this will restrict or prevent an attacker’s ability to com-promise the system. ABB recommends that customers apply the update at the earliest convenience. Mitigation Any exploit of these vulnerabilities would require that the attacker has access to the site’s S+ client/server network. Following ABB’s recommended security practices, including network architecture and perimeter firewall, are mitigating factors in preventing external access to the S+ client/server net-work. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C CVE-2023-39417 If an administrator has installed Extension scripts and specific data is used inside a quoting con-struct, an attacker having proper PostgreSQL privileges can execute arbitrary code in the system as the administrator. View CVE Details Affected Products ABB Ability Symphony Plus Engineering Vendor: ABB Product Version: ABB Ability Symphony Plus S+ Engineering 2.2, ABB Ability Symphony Plus S+ Engineering 2.3, ABB Ability Symphony Plus S+ Engineering 2.3 RU1, ABB Ability Symphony Plus S+ Engineering 2.3 RU2, ABB Ability Symphony Plus S+ Engineering 2.3 RU3, ABB Ability Symphony Plus S+ Engineering 2.4, ABB Ability Symphony Plus S+ Engineering 2.4 SP1, ABB Ability Symphony Plus S+ Engineering 2.4 SP2 Product Status: fixed, known_affected Remediations Vendor fix ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: - Systems using S+ Engineering 2.2 through 2.4 SP2 should upgrade to S+ Engineering 2.4 SP2 RU1 (re-leased in December 2024) or later. - End users who are unable to install one of these updates should immediately look to implement the Mitigation and Workarounds listed below as this will restrict or prevent an attacker’s ability to com-promise the system. ABB recommends that customers apply the update at the earliest convenience. Mitigation Any exploit of these vulnerabilities would require that the attacker has access to the site’s S+ client/server network. Following ABB’s recommended security practices, including network architecture and perimeter firewall, are mitigating factors in preventing external access to the S+ client/server net-work. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”. Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C CVE-2024-7348 A ‘time-of-check time-of-use’ (TOCTOU) race condition in a PostgreSQL can allow an attacker to easily execute arbitrary SQL functions by leveraging a PostgreSQL utility often executed with high privileges. View CVE Details Affected Products ABB Ability Symphony Plus Engineering Vendor: ABB Product Version: ABB Ability Symphony Plus S+ Engineering 2.2, ABB Ability Symphony Plus S+ Engineering 2.3, ABB Ability Symphony Plus S+ Engineering 2.3 RU1, ABB Ability Symphony Plus S+ Engineering 2.3 RU2, ABB Ability Symphony Plus S+ Engineering 2.3 RU3, ABB Ability Symphony Plus S+ Engineering 2.4, ABB Ability Symphony Plus S+ Engineering 2.4 SP1, ABB Ability Symphony Plus S+ Engineering 2.4 SP2 Product Status: fixed, known_affected Remediations Vendor fix ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: - Systems using S+ Engineering 2.2 through 2.4 SP2 should upgrade to S+ Engineering 2.4 SP2 RU1 (re-leased in December 2024) or later. - End users who are unable to install one of these updates should immediately look to implement the Mitigation and Workarounds listed below as this will restrict or prevent an attacker’s ability to com-promise the system. ABB recommends that customers apply the update at the earliest convenience. Mitigation Any exploit of these vulnerabilities would require that the attacker has access to the site’s S+ client/server network. Following ABB’s recommended security practices, including network architecture and perimeter firewall, are mitigating factors in preventing external access to the S+ client/server net-work. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”. Relevant CWE: CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C CVE-2024-0985 An attacker can provide untrusted materialized views and lure a high privileged authorized user to inadvertently execute arbitrary SQL functions by refreshing the attacker's materialized view. View CVE Details Affected Products ABB Ability Symphony Plus Engineering Vendor: ABB Product Version: ABB Ability Symphony Plus S+ Engineering 2.2, ABB Ability Symphony Plus S+ Engineering 2.3, ABB Ability Symphony Plus S+ Engineering 2.3 RU1, ABB Ability Symphony Plus S+ Engineering 2.3 RU2, ABB Ability Symphony Plus S+ Engineering 2.3 RU3, ABB Ability Symphony Plus S+ Engineering 2.4, ABB Ability Symphony Plus S+ Engineering 2.4 SP1, ABB Ability Symphony Plus S+ Engineering 2.4 SP2 Product Status: fixed, known_affected Remediations Vendor fix ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: - Systems using S+ Engineering 2.2 through 2.4 SP2 should upgrade to S+ Engineering 2.4 SP2 RU1 (re-leased in December 2024) or later. - End users who are unable to install one of these updates should immediately look to implement the Mitigation and Workarounds listed below as this will restrict or prevent an attacker’s ability to com-promise the system. ABB recommends that customers apply the update at the earliest convenience. Mitigation Any exploit of these vulnerabilities would require that the attacker has access to the site’s S+ client/server network. Following ABB’s recommended security practices, including network architecture and perimeter firewall, are mitigating factors in preventing external access to the S+ client/server net-work. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”. Relevant CWE: CWE-271 Privilege Dropping / Lowering Errors Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C Acknowledgments ABB Global reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What is the scope of the vulnerability? - An attacker who successfully exploited these vulnerabilities could insert and run arbitrary code in the S+ system. What causes the vulnerability? - It is caused by several vulnerabilities in the PostgreSQL version 13.11 and earlier versions component used by the S+ Engineering product (see Affected products). What might an attacker use the vulnerability to do? - An attacker who successfully accessed the site’s S+ client/server network could cause a denial-of-service situation, corruptions of data or unauthorized disclosure of information. How could an attacker exploit the vulnerability? - To exploit the PostgreSQL vulnerabilities (see Vulnerability severity and details), an attacker should successfully access to the site’s S+ client/server network, remotely (through a wrongly configured or penetrated firewall) or even compromising a local machine and then accessing to PostgreSQL. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? - Yes, see the above How could an attacker exploit the vulnerability? Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. Can functional safety be affected by an exploit of this vulnerability? - Functional safety systems are not affected by these vulnerabilities What does the update do? - The S+ Engineering update removes the vulnerability by installing a secure updated PostgreSQL version. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, PostgreSQL 13.11 vulnerabilities have been publicly disclosed. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that S+ Engineering had been exploited when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA017341 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-13 Date Revision Summary 2026-04-13 1 Initial version. 2026-04-30 2 Initial CISA Republication of ABB PSIRT 7PAA017341 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB System 800xA, Symphony Plus IEC 61850

View CSAF Summary This vulnerability was privately reported relating to ABB’s implementation of the IEC 61850 communication stack for MMS client applications used in some Automation control system products. Note: IEC 61850 communication typically supports MMS and GOOSE protocols. Some ABB products support both, others only MMS (e.g. S+ Operations and PM 877). In any case, GOOSE communication is not impacted by this…
Read full source summary
View CSAF Summary This vulnerability was privately reported relating to ABB’s implementation of the IEC 61850 communication stack for MMS client applications used in some Automation control system products. Note: IEC 61850 communication typically supports MMS and GOOSE protocols. Some ABB products support both, others only MMS (e.g. S+ Operations and PM 877). In any case, GOOSE communication is not impacted by this reported vulnerability. If an attacker gains access to a site’s IEC 61850 network, then exploiting this vulnerability will result in a device fault (PM 877, CI850 and CI868 modules) and will require a manual restart. If this attack is directed at a S+ Operations node running IEC 61850 connectivity, this will result in a crash in the IEC 61850 communication driver which, if continued a repeating basis, will also result in a denial-of-service situation. Note that this does not have an impact on the overall availability and functionality of the S+ Operations node, only the IEC 61850 communication function. The System 800xA IEC61850 Connect is not affected. The following versions of ABB System 800xA, Symphony Plus IEC 61850 are affected: AC800M Product line (System 800xA) CI868 Symphony Plus SD Series CI850 Symphony Plus MR (Melody Rack) PM 877 S+ Operations Firmware <=6.0.0303.0, <=6.1.0031.0 , <=6.1.1004.0 , <=6.1.1202.0 , <=6.2.0006.0 , 6.1.1-3, 7.0, A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005, C_0, >=3.10|<=3.52, 3.53, 3.3, 2.3, 2.2, 2.1, 3.4 () CVSS Vendor Equipment Vulnerabilities v3 6.5 ABB ABB System 800xA, Symphony Plus IEC 61850 Improper Validation of Specified Quantity in Input Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-3756 A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed above. An attacker with access to IEC 61850 networks could exploit the vulnerability by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation. The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function. View CVE Details Affected Products ABB System 800xA, Symphony Plus IEC 61850 Vendor: ABB Product Version: Product Status: fixed, known_affected Remediations Vendor fix ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: - CI868 (for AC 800M) Devices with firmware versions reported in Affected products are vulnerable. All the vulnerabilities will be corrected in 6.1.1 and 7.0 tracks for 800xA. AC 800M 6.1.1-3 is planned for Q2 2027, AC 800M 7.0 has been released in December 2025. - CI850 (for Symphony Plus SD Series) Devices with firmware versions reported in Affected products are vulnerable. All the vulnerabilities will be corrected in version C_0 or later (planned Q2 2026). - PM 877 (Symphony Plus MR) Devices with firmware versions reported in Affected products are vulnerable. All the vulnerabilities will be corrected with firmware version 3.53 or later (planned Q1 2026). - S+ Operations Versions reported in Affected products are vulnerable. All the vulnerabilities will be corrected in version 3.4 or later (released in January 2026). ABB recommends customers apply updates, as they become available, at their earliest convenience. It is also advisable to review the Mitigating Factors, Workarounds and General security recommendations sections for additional actions which may help reduce overall risk. Mitigation The vulnerabilities announced in this Advisory for ABB Process Automation products require that an attacker has access to the system network and hosts which are generally expected to be protected. Process Control and IEC 61850 networks are NOT recommended to be exposed directly to Internet connections. If these networks are not properly isolated, then connected components may be remotely exploitable as described in this advisory. To exploit the vulnerability, an attacker with remote network access can send a specially crafted packet to the PM 877, CI850 and CI868 modules which causes the fault of these devices. S+ Operations only implements 61850 client services and therefore are not intended to listen to in-coming connection requests. However, if a specially crafted message is sent anyway, it can still cause the 61850-communication driver to crash. The usage of a perimeter firewall to allow legitimate client communications is an effective mitigation. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”. Relevant CWE: CWE-1284 Improper Validation of Specified Quantity in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Hitachi Energy reported this vulnerability to ABB Global. ABB Global reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What is the scope of the vulnerability? - An attacker having access to the IEC 61850 network can force the ABB hardware devices to go to ‘fault’ state by sending a specially crafted 61850 packet. This will result in a denial-of-service situation affecting the primary functionality of the listed devices and requiring a manual reset. In the same way this vulnerability can cause the unavailability of the S+ Operations 61850 connectivity, if continued on a repeating basis (but not the whole S+ Operations node). The System 800xA IEC61850 Connect is not affected. What causes the vulnerability? - The vulnerability is caused by a weakness in the message processing in the IEC 61850 communication stack. What is CI868? - CI868 is a module used in AC800M product line (System 800xA) for IEC 61850 communication. What is CI850? - CI868 is a module used in Symphony Plus SD Series product line for IEC 61850 communication. What is PM 877? - PM 877 is a controller used in Symphony Plus MR (Melody Rack) product line for IEC 61850 communication. What is S+ Operations? - S+ Operations is the Human Machine Interface for supervision and control of Symphony based control or SCADA systems. It is a module used in AC800M product line (System 800xA) for IEC 61850 communication. What might an attacker use the vulnerability to do? - An attacker with access to IEC 61850 networks could exploit the vulnerability by sending a specially crafted 61850 packet to the S+ products, forcing the Communication Interfaces to fault modes or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation. How could an attacker exploit the vulnerability? - An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the net-work with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors. Could the vulnerability be exploited remotely? - Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. Can functional safety be affected by an exploit of this vulnerability? - Functional safety systems are not affected by these vulnerabilities. What does the update do? - The update removes the vulnerability by modifying the way that the IEC 61850 stack, used by the ABB Process Automation Products described above, manages 61850 incoming messages. When this security advisory was issued, had this vulnerability been publicly disclosed? - No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA020125 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-13 Date Revision Summary 2026-04-13 1 Initial version. 2026-04-30 2 Initial CISA Republication of ABB PSIRT 7PAA020125 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Adapting Zero Trust Principles to Operational Technology

Adapting Zero Trust Principles to Operational Technology CISA, in coordination with the Department of War, Department of Energy, Federal Bureau of Investigation, and Department of State, released Adapting Zero Trust Principles to Operational Technology, joint guidance for organizations applying zero trust (ZT) principles to operational technology (OT). Zero trust is a modern, adaptive approach to cybersecurity that…
Read full source summary
Adapting Zero Trust Principles to Operational Technology CISA, in coordination with the Department of War, Department of Energy, Federal Bureau of Investigation, and Department of State, released Adapting Zero Trust Principles to Operational Technology, joint guidance for organizations applying zero trust (ZT) principles to operational technology (OT). Zero trust is a modern, adaptive approach to cybersecurity that eliminates implicit trust and requires continuously validating access based on identity, context, and risk. With advancements in technology, OT systems that were traditionally isolated or manually operated are now increasingly interconnected, digitally monitored, and remotely controlled. This IT-OT convergence introduces new cybersecurity risks that make perimeter-based defenses and implicit trust models inadequate for safeguarding OT systems and the critical physical processes they control. This guidance supports OT owners and operators in addressing the unique challenges of transitioning to a ZT architecture, considering technology gaps from legacy infrastructure, operational constraints, and safety requirements. It focuses on establishing comprehensive asset visibility, proactively addressing supply chain risks, and implementing robust identity and access management while stressing the importance of layered security measures—including network segmentation, secure communication protocols, and vulnerability management. To learn more about ZT principles, visit Zero Trust CISA Product Survey We welcome your feedback. CISA Product Survey
· CISA Cybersecurity Advisory

NSA GRASSMARLIN

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to disclose sensitive information. The following versions of NSA GRASSMARLIN are affected: GRASSMARLIN vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.5 NSA NSA GRASSMARLIN Improper Restriction of XML External Entity Reference Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to disclose sensitive information. The following versions of NSA GRASSMARLIN are affected: GRASSMARLIN vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.5 NSA NSA GRASSMARLIN Improper Restriction of XML External Entity Reference Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6807 A vulnerability in GRASSMARLIN v3.2.1 allows crafted session data to trigger improper handling of XML input, which may result in unintended exposure of sensitive information. The flaw stems from insufficient hardening of the XML parsing process. View CVE Details Affected Products NSA GRASSMARLIN Vendor: NSA Product Version: NSA GRASSMARLIN: vers:all/* Product Status: known_affected Remediations Vendor fix NSA has indicated that the GRASSMARLIN project has reached end-of-life status as of 2017 and is no longer supported. The project is archived, and no patches or further updates are planned or expected. Relevant CWE: CWE-611 Improper Restriction of XML External Entity Reference Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N Acknowledgments Grady DeRosa reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-28 Date Revision Summary 2026-04-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-1708 ConnectWise ScreenConnect Path Traversal Vulnerability CVE-2026-32202 Microsoft Windows Protection Mechanism Failure Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-1708 ConnectWise ScreenConnect Path Traversal Vulnerability CVE-2026-32202 Microsoft Windows Protection Mechanism Failure Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-7399 Samsung MagicINFO 9 Server Path Traversal Vulnerability CVE-2024-57726 SimpleHelp Missing Authorization Vulnerability CVE-2024-57728 SimpleHelp Path Traversal Vulnerability CVE-2025-29635 D-Link DIR-823X Command Injection Vulnerability These types of vulnerabilities…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-7399 Samsung MagicINFO 9 Server Path Traversal Vulnerability CVE-2024-57726 SimpleHelp Missing Authorization Vulnerability CVE-2024-57728 SimpleHelp Path Traversal Vulnerability CVE-2025-29635 D-Link DIR-823X Command Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Carlson Software VASCO-B GNSS Receiver

View CSAF Summary Successful exploitation of this vulnerability could enable a remote attacker to alter critical system functions or disrupt device operation. The following versions of Carlson Software VASCO-B GNSS Receiver are affected: VASCO-B GNSS Receiver <1.4.0 (CVE-2026-3893) CVSS Vendor Equipment Vulnerabilities v3 9.4 Carlson Software Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could enable a remote attacker to alter critical system functions or disrupt device operation. The following versions of Carlson Software VASCO-B GNSS Receiver are affected: VASCO-B GNSS Receiver <1.4.0 (CVE-2026-3893) CVSS Vendor Equipment Vulnerabilities v3 9.4 Carlson Software Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3893 The Carlson VASCO-B GNSS Receiver lacks an authentication mechanism, allowing an attacker with network access to directly access and modify its configuration and operational functions without needing credentials. View CVE Details Affected Products Carlson Software VASCO-B GNSS Receiver Vendor: Carlson Software Product Version: Carlson Software VASCO-B GNSS Receiver: <1.4.0 Product Status: known_affected Remediations Mitigation Carlson Software recommends users update to Version 1.4.0 or greater. For more information contact Carlson Software https://www.carlsonsw.com/support-and-training/ https://www.carlsonsw.com/support-and-training/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H Acknowledgments Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass authentication and have remote access to sensitive information on the device. The following versions of Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera are affected: IP Camera XM530V200_X6-WEQ_8M firmware V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 (CVE-2025-65856) CVSS Vendor Equipment Vulnerabilities v3 9.8…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass authentication and have remote access to sensitive information on the device. The following versions of Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera are affected: IP Camera XM530V200_X6-WEQ_8M firmware V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 (CVE-2025-65856) CVSS Vendor Equipment Vulnerabilities v3 9.8 Hangzhou Xiongmai Technology Co., Ltd Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-65856 Authentication bypass vulnerability in Xiongmai XM530 IP cameras on Firmware V5.00.R02.000807D8.10010.346624.S.ONVIF 21.06 allows unauthenticated remote attackers to access sensitive device information and live video streams. The ONVIF implementation fails to enforce authentication on 31 critical endpoints, enabling direct unauthorized video stream access. View CVE Details Affected Products Hangzhou Xiongmai Technology Co., Ltd XM530 IP Camera Vendor: Hangzhou Xiongmai Technology Co., Ltd Product Version: Hangzhou Xiongmai Technology Co., Ltd IP Camera XM530V200_X6-WEQ_8M firmware: V5.00.R02.000807D8.10010.346624.S.ONVIF_21.06 Product Status: known_affected Remediations Mitigation Hangzhou Xiongmai Technology Co., Ltd has not responded to requests to work with CISA to mitigate this vulnerability. Users of affected versions of XM530 IP cameras are invited to contact Xiongmai Technology customer support for additional information (https://www.xiongmaitech.com/en/index.php/about/contact/42). https://www.xiongmaitech.com/en/index.php/about/contact/42 Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments CISA discovered a public Proof of Concept (PoC) as authored by Luis Miranda Acebedo and reported it to MITRE Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SpiceJet Online Booking System

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information. The following versions of SpiceJet Online Booking System are affected: Online Booking System vers:all/* (CVE-2026-6375, CVE-2026-6376) CVSS Vendor Equipment Vulnerabilities v3 7.5 SpiceJet SpiceJet Online Booking System Authorization Bypass Through User-Controlled Key, Missing Authentication…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information. The following versions of SpiceJet Online Booking System are affected: Online Booking System vers:all/* (CVE-2026-6375, CVE-2026-6376) CVSS Vendor Equipment Vulnerabilities v3 7.5 SpiceJet SpiceJet Online Booking System Authorization Bypass Through User-Controlled Key, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-6375 A vulnerability in SpiceJet's booking API allows unauthenticated users to query passenger name records (PNRs) without any access controls. Because PNR identifiers follow a predictable pattern, an attacker could systematically enumerate valid records and obtain associated passenger names. This flaw stems from missing authorization checks on an endpoint intended for authenticated profile access. View CVE Details Affected Products SpiceJet Online Booking System Vendor: SpiceJet Product Version: SpiceJet Online Booking System: vers:all/* Product Status: known_affected Remediations Mitigation SpiceJet did not respond to CISA's requests to coordinate. Users are encouraged to reach out to SpiceJet for more information: https://corporate.spicejet.com/contactus.aspx https://corporate.spicejet.com/contactus.aspx Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-6376 A weakness in SpiceJet's public booking retrieval page permits full passenger booking details to be accessed using only a PNR and last name, with no authentication or verification mechanisms. This results in exposure of extensive personal, travel, and booking metadata to any unauthenticated user who can obtain or guess those basic inputs. The issue arises from improper access control on a sensitive data retrieval function. View CVE Details Affected Products SpiceJet Online Booking System Vendor: SpiceJet Product Version: SpiceJet Online Booking System: vers:all/* Product Status: known_affected Remediations Mitigation SpiceJet did not respond to CISA's requests to coordinate. Users are encouraged to reach out to SpiceJet for more information: https://corporate.spicejet.com/contactus.aspx https://corporate.spicejet.com/contactus.aspx Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Owais Shaikh reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Intrado 911 Emergency Gateway (EGW)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read, modify, or delete files. The following versions of Intrado 911 Emergency Gateway (EGW) are affected: Emergency Gateway 7.x (CVE-2026-6074) Emergency Gateway 6.x (CVE-2026-6074) Emergency Gateway 5.x (CVE-2026-6074) CVSS Vendor Equipment Vulnerabilities v3 9.8 Intrado Intrado 911 Emergency Gateway (EGW) Path Traversal:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read, modify, or delete files. The following versions of Intrado 911 Emergency Gateway (EGW) are affected: Emergency Gateway 7.x (CVE-2026-6074) Emergency Gateway 6.x (CVE-2026-6074) Emergency Gateway 5.x (CVE-2026-6074) CVSS Vendor Equipment Vulnerabilities v3 9.8 Intrado Intrado 911 Emergency Gateway (EGW) Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Emergency Services Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6074 A path traversal condition in Intrado 911 Emergency Gateway could allow an attacker with existing network access the ability to access the EGW management interface without authentication. Successful exploitation of this vulnerability could allow a user to read, modify, or delete files. View CVE Details Affected Products Intrado 911 Emergency Gateway (EGW) Vendor: Intrado Product Version: Intrado Emergency Gateway: 7.x, Intrado Emergency Gateway: 6.x, Intrado Emergency Gateway: 5.x Product Status: known_affected Remediations Mitigation Intrado developed and released a software update on March 2nd, 2026, that addresses this issue and has contacted customers to coordinate applying the patch. Mitigation If you have questions, contact Intrado E911 Support: E911Support@intrado.com mailto:E911Support@intrado.com Relevant CWE: CWE-35 Path Traversal: '.../...//' Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments An anonymous source reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Milesight Cameras

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed or allow remote code execution. The following versions of Milesight Cameras are affected: MS-Cxx63-PD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx64-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed or allow remote code execution. The following versions of Milesight Cameras are affected: MS-Cxx63-PD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx64-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx73-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx75-xxPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx83-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx74-PA <=3x.8.0.3-r11 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C8477-HPG1 <=63.8.0.4-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C8477-PC <=48.8.0.4-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5321-FPE <=62.8.0.4-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx62-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx52-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxGPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx61-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx67-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx71-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx41-xxxPE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx76-PE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx65-PE <=61.8.0.5-r2 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx62-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-xxxG1 <=63.8.0.5-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx31-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx68-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-CQxx72-xxxG1 <=CQ_63.8.0.5-r1 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-NxE <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxC <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxE <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxG <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxH <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Nxxxx-xxT <=7x.9.0.19-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PMC8266-FPE <=PO_61.8.0.4_LPR (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PMC8266-FGPE <=PO_61.8.0.4_LPR (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) PM3322-E <=PI_61.8.0.3_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-RFIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-RFIVPG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RIWG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4RIWG1 <=T_63.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5510-GVH <=T_47.8.0.4_LPR-r7 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5510-GH <=T_47.8.0.4_LPR-r6 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5511-GVH <=T_47.8.0.4_LPR-r6 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2966-X12TPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12PE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4PE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2966-X12TVPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RVPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS5366-X12VPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4VPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4441-X36RPE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4441-X36RE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS4466-X4RWE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-X4WE <=T_61.8.0.4_LPR-r3 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2964-RFLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2972-RFLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-RFLWPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2866-X4TGPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2841-X36TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2841-X36TPC/W <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2867-X5TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS2961-X12TPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) TS8266-FPC/P <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-X12RLPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C2966-X12RLVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5366-X12LPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5366-X12LVPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-C5361-X12LPC <=T_45.8.0.3-r9 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-xxxxGOPC <=45.8.0.2-AIoT-r4 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) SC211 <=C_21.1.0.8-r4 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) SP111 <=52.8.0.4-r5 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-RFIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-RFIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx66-FIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx72-FIPKG1 <=63.8.0.4-r1-NX (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) CVSS Vendor Equipment Vulnerabilities v3 9.8 Milesight Milesight Cameras Authorization Bypass Through User-Controlled Key, Use of Hard-coded Credentials, Use of Hard-coded Cryptographic Key, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-28747 A weak key generation vulnerability exists in specific firmware versions of Milesight AIOT cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-27785 Specific firmware versions of Milesight AIOT camera firmware contain hard-coded credentials. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32644 Specific firmware versions of Milesight AIOT cameras use SSL certificates with default private keys. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-32649 A command injection vulnerability exists in the web server of specific firmware versions of Milesight cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions : Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC : 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H CVE-2026-20766 An out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras. View CVE Details Affected Products Milesight Cameras Vendor: Milesight Product Version: Milesight MS-Cxx63-PD: <=51.7.0.77-r12, Milesight MS-Cxx64-xPD: <=51.7.0.77-r12, Milesight MS-Cxx73-xPD: <=51.7.0.77-r12, Milesight MS-Cxx75-xxPD: <=51.7.0.77-r12, Milesight MS-Cxx83-xPD: <=51.7.0.77-r12, Milesight MS-Cxx74-PA: <=3x.8.0.3-r11, Milesight MS-C8477-HPG1: <=63.8.0.4-r3, Milesight MS-C8477-PC: <=48.8.0.4-r3, Milesight MS-C5321-FPE: <=62.8.0.4-r5, Milesight MS-Cxx72-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx62-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx52-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxGPE: <=61.8.0.5-r2, Milesight MS-Cxx61-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx67-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx71-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx41-xxxPE: <=61.8.0.5-r2, Milesight MS-Cxx76-PE: <=61.8.0.5-r2, Milesight MS-Cxx65-PE: <=61.8.0.5-r2, Milesight MS-Cxx66-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx62-xxxG1: <=63.8.0.5-r3, Milesight MS-Cxx72-xxxG1: <=63.8.0.5-r3, Milesight MS-CQxx31-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx68-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-CQxx72-xxxG1: <=CQ_63.8.0.5-r1, Milesight MS-Nxxxx-NxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxC: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxE: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxG: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxH: <=7x.9.0.19-r5, Milesight MS-Nxxxx-xxT: <=7x.9.0.19-r5, Milesight PMC8266-FPE: <=PO_61.8.0.4_LPR, Milesight PMC8266-FGPE: <=PO_61.8.0.4_LPR, Milesight PM3322-E: <=PI_61.8.0.3_LPR-r3, Milesight TS4466-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS5366-X12RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-RFIVPG1: <=T_63.8.0.4_LPR-r3, Milesight TS4466-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS8266-X4RIWG1: <=T_63.8.0.4_LPR-r3, Milesight TS5510-GVH: <=T_47.8.0.4_LPR-r7, Milesight TS5510-GH: <=T_47.8.0.4_LPR-r6, Milesight TS5511-GVH: <=T_47.8.0.4_LPR-r6, Milesight TS2966-X12TPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12PE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4PE: <=T_61.8.0.4_LPR-r3, Milesight TS2966-X12TVPE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RVPE: <=T_61.8.0.4_LPR-r3, Milesight TS5366-X12VPE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4VPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RPE: <=T_61.8.0.4_LPR-r3, Milesight TS4441-X36RE: <=T_61.8.0.4_LPR-r3, Milesight TS4466-X4RWE: <=T_61.8.0.4_LPR-r3, Milesight TS8266-X4WE: <=T_61.8.0.4_LPR-r3, Milesight MS-C2964-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2972-RFLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-RFLWPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TVPC: <=T_45.8.0.3-r9, Milesight TS2866-X4TGPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC: <=T_45.8.0.3-r9, Milesight TS2841-X36TPC/W: <=T_45.8.0.3-r9, Milesight TS2867-X5TPC: <=T_45.8.0.3-r9, Milesight TS2961-X12TPC: <=T_45.8.0.3-r9, Milesight TS8266-FPC/P: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLPC: <=T_45.8.0.3-r9, Milesight MS-C2966-X12RLVPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LPC: <=T_45.8.0.3-r9, Milesight MS-C5366-X12LVPC: <=T_45.8.0.3-r9, Milesight MS-C5361-X12LPC: <=T_45.8.0.3-r9, Milesight MS-Cxx66-xxxxGOPC: <=45.8.0.2-AIoT-r4, Milesight SC211: <=C_21.1.0.8-r4, Milesight SP111: <=52.8.0.4-r5, Milesight MS-Cxx66-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-RFIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx66-FIPKG1: <=63.8.0.4-r1-NX, Milesight MS-Cxx72-FIPKG1: <=63.8.0.4-r1-NX Product Status: known_affected Remediations Mitigation Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware Vendor fix MS-Cxx63-PD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx64-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx73-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx75-xxPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx83-xPD: 51.7.0.77-r12 and prior versions: Update to 51.7.0.77-r13 Vendor fix MS-Cxx74-PA: 3x.8.0.3-r11 and prior versions: Update to 3x.8.0.3-r13 Vendor fix MS-C8477-HPG1: 63.8.0.4-r3 and prior versions: Update to 63.8.0.4-r4 Vendor fix MS-C8477-PC: 48.8.0.4-r3 and prior versions: Update to 48.8.0.4-r4 Vendor fix MS-C5321-FPE: 62.8.0.4-r5 and prior versions: Update to 62.8.0.4-r6 Vendor fix MS-Cxx72-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx62-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx52-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxGPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx61-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx67-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx71-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx41-xxxPE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx76-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx65-PE: 61.8.0.5-r2 and prior versions: Update to 61.8.0.5-r2 Vendor fix MS-Cxx66-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx62-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-Cxx72-xxxG1: 63.8.0.5-r3 and prior versions: Update to 63.8.0.5-r4 Vendor fix MS-CQxx31-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx68-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-CQxx72-xxxG1: CQ_63.8.0.5-r1 and prior versions: Update to CQ_63.8.0.5-r2 Vendor fix MS-Nxxxx-NxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxC: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxE: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxG: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxH: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix MS-Nxxxx-xxT: 7x.9.0.19-r5 and prior versions: Update to 7x.9.0.19-r6 Vendor fix PMC8266-FPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PMC8266-FGPE: PO_61.8.0.4_LPR and prior versions: Update to PO_61.8.0.4-r1 Vendor fix PM3322-E: PI_61.8.0.3_LPR-r3 and prior versions: Update to PI_61.8.0.3-r5 Vendor fix TS4466-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5366-X12RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-RFIVPG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS4466-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS8266-X4RIWG1: T_63.8.0.4_LPR-r3 and prior versions: Update to T_63.8.0.4-r4 Vendor fix TS5510-GVH: T_47.8.0.4_LPR-r7 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5510-GH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS5511-GVH: T_47.8.0.4_LPR-r6 and prior versions: Update to T_47.8.0.4-r8 Vendor fix TS2966-X12TPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4PE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS2966-X12TVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RVPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS5366-X12VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4VPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RPE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4441-X36RE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS4466-X4RWE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix TS8266-X4WE: T_61.8.0.4_LPR-r3 and prior versions: Update to T_61.8.0.4-r4 Vendor fix MS-C2964-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2972-RFLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-RFLWPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2866-X4TGPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2841-X36TPC/W: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2867-X5TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS2961-X12TPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix TS8266-FPC/P: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C2966-X12RLVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5366-X12LVPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-C5361-X12LPC: T_45.8.0.3-r9 and prior versions: Update to T_45.8.0.3-r10 Vendor fix MS-Cxx66-xxxxGOPC: 45.8.0.2-AIoT-r4 and prior versions: Update to 45.8.0.2-AIoT-r5 Vendor fix SC211: C_21.1.0.8-r4 and prior versions: Update to C_21.1.0.8-r5 Vendor fix SP111: 52.8.0.4-r5 and prior versions: Update to 52.8.0.4-r6 Vendor fix MS-Cxx66-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-RFIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx66-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Vendor fix MS-Cxx72-FIPKG1: 63.8.0.4-r1-NX and prior versions: Update to 63.8.0.5-r2-NX Mitigation Milesight asks all users to report potential security vulnerabilities to security@milesight.com. mailto:security@milesight.com Mitigation Learn more: Milesight Vulnerability Reporting Policy https://www.milesight.com/legal/vulnerability-report Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Souvik Kandar reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Defending Against China-Nexus Covert Networks of Compromised Devices

Defending against china-nexus covert networks of compromised devices executive summary Defending against China-nexus covert networks of compromised devices Explaining the widespread shift in tactics, techniques and procedures (TTPs) towards networks of compromised infrastructure, and how to defend against it Summary With support from the UK Cyber League, this advisory has been jointly released by the National Cyber…
Read full source summary
Defending against china-nexus covert networks of compromised devices executive summary Defending against China-nexus covert networks of compromised devices Explaining the widespread shift in tactics, techniques and procedures (TTPs) towards networks of compromised infrastructure, and how to defend against it Summary With support from the UK Cyber League, this advisory has been jointly released by the National Cyber Security Centre (NCSC-UK) and international partners: Australian Signals Directorate’s (ASD’s) Australian Cyber Security Centre (ACSC) Communications Security Establishment Canada’s (CSE’s) Canadian Centre for Cyber Security (Cyber Centre) Germany Federal Office for the Protection of the Constitution - Bundesamt für Verfassungsschutz (BfV) Germany Federal Intelligence Service – Bundesnachrichtendienst (BND) Germany Federal Office for Information Security - Bundesamt für Sicherheit in der Informationstechnik (BSI) Japan National Cybersecurity Office (NCO) - 国家サイバー統括室 Netherlands General Intelligence and Security Service - Algemene Inlichtingen- en Veiligheidsdienst (AIVD) Netherlands Defence Intelligence and Security Service - Militaire Inlichtingen- en Veiligheidsdienst (MIVD) New Zealand National Cyber Security Centre (NCSC-NZ) Spain National Cryptologic Centre – Centro Criptológico Nacional (CCN) Sweden National Cyber Security Centre - Nationellt cybersäkerhetscenter (NCSC-SE) United States Cybersecurity and Infrastructure Security Agency (CISA) United States Department of Defense Cyber Crime Center (DC3) United States Federal Bureau of Investigation (FBI) United States National Security Agency (NSA) Its purpose is to provide network defenders with the tools needed to defend against China-nexus cyber actors and their tactic of using large scale networks of compromised devices (covert networks) to route their cyber activity. Introduction Over the past few years there has been a major shift in the tactics, techniques and procedures (TTPs) used by China-nexus cyber actors, moving away from the use of individually procured infrastructure, and towards the use of externally provisioned, large-scale networks of compromised devices. The NCSC believes that the majority of China-nexus threat actors are using these networks (hereafter “covert networks”), that multiple covert networks have been created and are being constantly updated, and that a single covert network could be being used by multiple actors. These networks are mainly made up of compromised Small Office Home Office (SOHO) routers, as well as Internet of Things (IoT) and smart devices. Anyone who is a target of China-nexus cyber actors may be impacted by the use of covert networks. They have been used by Chinese state-sponsored actors Volt Typhoon to pre-position offensive cyber capabilities on critical national infrastructure. The group Flax Typhoon used a different covert network of compromised infrastructure to conduct cyber espionage. The use of covert networks of compromised devices - also known as botnets - to facilitate malicious cyber activity is not new, but China-nexus cyber actors are now using them strategically, and at scale. This advisory describes the typical makeup of a covert network and what they are being used for. It also includes protective advice for organizations being targeted by cyber activity using a covert network as an access vector. Covert Networks Covert networks are used to connect across the internet in a low-cost, low-risk, deniable way, disguising the origin and attribution of malicious activity. Actors have been observed using them for each phase of their Cyber Kill Chains, from performing scans as part of reconnaissance, to the delivery of malware, communicating with said malware, and exfiltrating stolen data from a victim. They can also be used for general deniable internet browsing, allowing threat actors to research exploitation techniques, new TTPs, and their victims without attribution. Some covert networks are also used by legitimate customers to browse the internet, making it challenging to attribute malicious activity. There is evidence that covert networks used by China-nexus actors are created and maintained by Chinese information security companies. A network known to network defenders as Raptor Train, which in 2024 infected more than 200,000 devices worldwide, was controlled and managed by the Chinese company, Integrity Technology Group. This company was also assessed by the FBI to be responsible for the computer intrusion activities attributed to China-based hackers known as Flax Typhoon. Botnet operations represent a significant threat to the UK by exploiting vulnerabilities in everyday internet-connected devices with the potential to carry out large-scale cyber attacks – NCSC Director of Operations, Paul Chichester Covert networks mostly consist of compromised SOHO routers, but they also pull in any vulnerable device they can exploit at scale. Raptor Train was made up of thousands of SOHO routers and IoT devices, such as web cameras and video recorders, as well as firewalls and Network Attached Storage (NAS) devices. The KV Botnet used by Volt Typhoon was mainly made up of vulnerable Cisco and NetGear routers. The edge devices were vulnerable because they were “end of life” – out of date and no longer receiving updates or security patches by their manufacturers. The cyber security industry has been aware of examples of these networks for some time and has publicly reported on the widespread scale of the threat and its implications. Mandiant Intelligence produced a public blog in May 2024 talking about covert networks in which they highlighted a key issue for defenders – indicator of compromise (IOC) Extinction. If a particular threat group could now come from one of many covert networks, each with potentially hundreds of thousands of endpoints, and each used by multiple threat actors, old network defense paradigms of static malicious IP block lists will be less effective. This is compounded by the dynamic nature of these networks where new nodes will be added as old devices are patched or removed from use. Typical Network Topology The number of covert networks used by China-nexus cyber actors is large, with new networks regularly developed and deployed. The existing covert networks change too, either because of defensive or legal action, or simply as a result of software updates and new exploits being used to target different technologies for incorporation into the network. Because of this, a description of all known covert networks in detail, including how they are constructed and how they communicate, would immediately be out of date – and for most network defenders would not be practically useful. However, most covert networks of compromised devices use the same basic set up. Understanding this generalized structure can aid researchers and defenders by helping them to understand which part of a network they may have found, and how to defend against it. A diagram illustrating the basic setup of a covert network. The diagram above illustrates the basic setup of a covert network, where typically an actor will connect to the network via an on-ramp or entry node. Their traffic will be forwarded through multiple compromised devices, used as traversal nodes, before exiting the network from an exit node, usually in the same geographic region as the target. Protective Advice Defending from attackers using covert networks is not straightforward, and defensive tactics will be different based on the levels of resource and the nature of the target organization. General advice for good cyber security practice should be followed, and some key messages can be found in the appendix of this advisory. The following advice is specifically tailored to steps which can be taken to combat the risk of attacks coming from large, dynamic networks of compromised devices. Further guidance for all organizations facing cyber security threats is available on the NCSC website. This guidance should be considered alongside all applicable laws and regulations of the UK and co-sealing countries relating to the security of networks and data. It will be each organization’s responsibility to ensure compliance with any such laws and regulations. Organizations should note that following the recommended actions set out below will not remove all risks. All organizations The NCSC recommends the following steps for all affected organizations to either take themselves, or ask their managed service and/or security providers to investigate for them: Map and understand network edge devices, developing a clear understanding of organizational assets and what should be connecting to them. Baseline normal connections, especially to corporate virtual private networks (VPNs) or other similar services. Would you expect connections from consumer broadband ranges? Leverage available dynamic threat feeds which include covert network infrastructure. Implement multifactor authentication for remote connections. Smaller organizations should consider creating and actioning a free NCSC Cyber Action Toolkit. Larger or more at-risk organizations Some more comprehensive measures may be appropriate if the risk to an organization is high enough, to be conducted either in-house or through a security provider: Apply IP address allow lists rather than deny lists for connections to corporate VPNs for remote workers. Use geographic allow lists or profile incoming connections based on operating system, time zones, and/or organization specific system configuration settings. Implement zero trust policies for connections. Enforce machine certificates for Secure Sockets Layer (SSL) connections. Reduce the internet-facing presence of the IT estate. Investigate machine learning techniques to profile normal network edge activity to detect and block anomalies. The NCSC's Cyber Essentials can help protect organizations of all sizes. Largest or most at-risk organizations If Advanced Persistent Threat (APT) tracking is part of an organization’s in-house capability, or if it is part of the service provided by a security vendor, consider tracking China-nexus covert networks as APTs in their own right. Active hunting – look for connections from IP addresses likely to be part of a covert network of compromised devices, for instance those hosting SOHO routers or IoT devices. Track and map covert networks reported by industry or government by looking at banners and certificates. Use threat reporting and threat feeds to create and implement dynamic blocklists and create alert rules to detect incoming threats. Consider using NetFlow feeds to look upstream and map covert networks to find new nodes. The NCSC Cyber Assessment Framework provides guidance for organizations under the highest levels of threat, including those operating essential services, in sectors such as energy, healthcare, transport, digital infrastructure and government. MITRE ATT&CK® This advisory has been compiled with respect to the MITRE ATT&CK® framework, a globally accessible knowledge base of adversary tactics and techniques based on real-world observations. Tactic ID Technique Procedure Resource Development T1584.005 Compromise Infrastructure: Botnet Botnets are used as core components of covert networks Resource Development T1584.008 Compromise Infrastructure: Network Devices Devices are compromised and added to botnets Resource Development T1583.003 Acquire Infrastructure: Virtual Private Server Virtual private servers (VPS) are used in covert networks, typically as on-ramps Command and Control T1090.003 Proxy: Multi-hop Proxy Used by China-nexus cyber actors to route traffic Appendix: Cyber Security Best Practices In addition to the protective advice outlined in this advisory, a number of cyber security best practices will also be useful in defending against the activity described in this advisory. Protect your devices and networks by keeping them up to date: use the latest supported versions, apply security updates promptly, use antivirus and scan regularly to guard against known malware threats. See NCSC Guidance: https://www.ncsc.gov.uk/collection/device-security-guidance/policies-and-settings/antivirus-and-other-security-software Prevent and detect lateral movement in your organization’s networks. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/preventing-lateral-movement Implement architectural controls for network segregation. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/10-steps-network-security Set up a security monitoring capability so you are collecting the data that will be needed to analyze network intrusions. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/introduction-logging-security-purposes and https://www.ncsc.gov.uk/information/logging-made-easy Use modern systems and software. These have better security built-in. If you cannot move off out-of-date platforms and applications straight away, there are short term steps you can take to improve your position. See NCSC Guidance: https://www.ncsc.gov.uk/collection/mobile-device-guidance/managing-the-risks-from-obsolete-products Restrict intruders' ability to move freely around your systems and networks. Pay particular attention to potentially vulnerable entry points such as third-party systems with onward access to your core network. During an incident, disable remote access from third-party systems until you are sure they are clean. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/preventing-lateral-movement and https://www.ncsc.gov.uk/guidance/assessing-supply-chain-security. Deploy a host-based intrusion detection system. A variety of products are available, free and paid-for, to suit different needs and budgets. Further information: Invest in preventing malware-based attacks across various scenarios. See NCSC Guidance: https://www.ncsc.gov.uk/guidance/mitigating-malware-and-ransomware-attacks Disclaimer This report draws on information derived from NCSC and industry sources. Any NCSC findings and recommendations made have not been provided with the intention of avoiding all risks and following the recommendations will not remove all such risk. Ownership of information risks remains with the relevant system owner at all times. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by co-sealers. UK readers should refer to the NCSC website for information about NCSC assured services. This information is exempt under the Freedom of Information Act 2000 (FOIA) and may be exempt under other UK information legislation. Refer any FOIA queries to ncscinfoleg@ncsc.gov.uk. All material is UK Crown Copyright ©
· CISA Cybersecurity Advisory

Yadea T5 Electric Bicycle

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker being able to unlock and start the bicycle, leading to vehicle theft. The following versions of Yadea T5 Electric Bicycle are affected: T5 Electric Bicycle vers:all/* (CVE-2025-70994) CVSS Vendor Equipment Vulnerabilities v3 7.3 Yadea Yadea T5 Electric Bicycle Weak Authentication Background Critical Infrastructure Sectors:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker being able to unlock and start the bicycle, leading to vehicle theft. The following versions of Yadea T5 Electric Bicycle are affected: T5 Electric Bicycle vers:all/* (CVE-2025-70994) CVSS Vendor Equipment Vulnerabilities v3 7.3 Yadea Yadea T5 Electric Bicycle Weak Authentication Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2025-70994 Yadea T5 Electric Bicycles have a weak authentication mechanism which is vulnerable to signal forgery after a local attacker intercepts any legitimate key fob transmissions. View CVE Details Affected Products Yadea T5 Electric Bicycle Vendor: Yadea Product Version: Yadea T5 Electric Bicycle: vers:all/* Product Status: known_affected Remediations Mitigation Yadea did not respond to CISA's attempts at coordination. Users of Yadea T5 Electric Bicycles are encouraged to keep their systems up to date and lock their property securely with external mechanisms. Users can contact Yadea at https://yadea.com/contact-us. https://yadea.com/contact-us Relevant CWE: CWE-1390 Weak Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H Acknowledgments Ashen Chathuranga reported this vulnerability to MITRE and CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-04-23 Date Revision Summary 2026-04-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-39987 Marimo Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-39987 Marimo Remote Code Execution Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

FIRESTARTER Backdoor

Malware Analysis Report at a Glance Malware Name FIRESTARTER Original Publication April 23, 2026 Executive Summary The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess advanced persistent threat (APT) actors are using FIRESTARTER malware for persistence,…
Read full source summary
Malware Analysis Report at a Glance Malware Name FIRESTARTER Original Publication April 23, 2026 Executive Summary The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess advanced persistent threat (APT) actors are using FIRESTARTER malware for persistence, specifically targeting publicly accessible Cisco Firepower and Secure Firewall devices running Adaptive Security Appliance (ASA) or Firepower Threat Defense (FTD) software. CISA and the NCSC are releasing this Malware Analysis Report to share analysis of one FIRESTARTER malware sample operating as a backdoor and urge organizations to take key response actions. Note: The release of this Malware Analysis Report aligns with CISA’s update to V1: Emergency Directive (ED) 25-03: Identify and Mitigate Potential Compromise of Cisco Devices and Supplemental Direction ED 25-03: Core Dump and Hunt Instructions. The malware outlined in this report is relevant for both Cisco Firepower and Secure Firewall devices; however, CISA has only observed a successful implant of the malware in the wild on a Cisco Firepower device running ASA software. Key Actions for U.S. FCEB Agencies Collect and submit core dumps to CISA’s Malware Next Generation platform. Immediately report the submission via CISA’s 24/7 Operations Center; CISA will reach out with next steps. Take no additional action until CISA provides further guidance. Key Actions for All Other Organizations Use the YARA rules to detect FIRESTARTER malware against either a disk image or core dump of a device. Report any findings to CISA or the NCSC. If compromise is confirmed, conduct incident response actions. Intended Audience Organizations: Government and critical infrastructure organizations (Note: While this publication supplements CISA ED 25-03, the guidance is applicable to all organizations, including U.K. organizations.) Sector: Government Services and Facilities Sector Roles: Digital forensics analysts, incident responders, vulnerability analysts, system administrators Introduction The Cybersecurity and Infrastructure Security Agency (CISA) analyzed a sample of FIRESTARTER malware obtained from a forensic investigation. CISA and the United Kingdom National Cyber Security Centre (NCSC) assess that FIRESTARTER—a backdoor that allows remote access and control—is part of a widespread campaign that afforded an advanced persistent threat (APT) actor initial access to Cisco Adaptive Security Appliance (ASA) firmware by exploiting CVE-2025-20333 [CWE-862: Missing Authorization] and/or CVE-2025-20362 [CWE-120: Classic Buffer Overflow]. For more information on this campaign, see CISA’s original version of Emergency Directive (ED) 25-03: Identify and Mitigate Potential Compromise of Cisco Devices (released Sept. 25, 2025). CISA and the NCSC assess that FIRESTARTER can persist as an active threat on Cisco devices running ASA or Firepower Threat Defense (FTD) software, maintaining post-patching persistence and enabling threat actors to re-access compromised devices without re-exploiting vulnerabilities. U.S. Federal Civilian Executive Branch (FCEB) agencies are required to implement the new required actions in CISA’s updated Emergency Directive (V1: ED 25-03). CISA and the NCSC urge other U.S. and U.K. organizations to use the YARA rules to detect FIRESTARTER malware against either a disk image or core dump of a device and report any findings to CISA or the NCSC. Organizations can also refer to Cisco’s Security Advisory and Talos Blog. Download the PDF version of this report: AR26-113A_MAR_FIRESTARTER_backdoor_ (PDF, 604.62 KB ) For a downloadable copy of the YARA rules associated with this malware, see: FIRESTARTER_STIX (JSON, 24.27 KB ) FIRESTARTER Collection CISA is authorized to monitor for, analyze, and notify U.S. FCEB agencies of anomalous or suspected malicious activity detected on federal networks. Through continuous monitoring, CISA identified suspicious connections on one U.S. FCEB agency’s Cisco Firepower device running ASA software. CISA notified and validated the true positive finding with agency personnel and initiated a forensic engagement. During the engagement, CISA discovered one malware sample—named FIRESTARTER—on the Firepower device. In this incident, APT actors initially deployed LINE VIPER as a post-exploitation implant and subsequently used FIRESTARTER as a persistence mechanism to maintain continued access to the compromised device. Although Cisco’s patches addressed CVE-2025-20333 and CVE-2025-20362, devices compromised prior to patching may remain vulnerable because FIRESTARTER is not removed by firmware updates. Threat Actor Activity Note: This advisory uses the MITRE ATT&CK® Matrix for Enterprise framework, version 18. See Appendix A: MITRE ATT&CK Techniques for tables mapping the cyber actors’ activity to MITRE ATT&CK tactics and techniques. CISA’s analysis identified the following: Initial Access: CISA assesses, but has not confirmed, that APT actors obtained initial access by exploiting CVE-2025-20333 and/or CVE-2025-20362 [T1190]. CISA has not confirmed the exact date of initial exploitation but assesses the compromise occurred in early September 2025, and before the agency implemented patches in accordance with ED 25-03. Privilege Escalation and Defense Evasion: CISA identified that APT actors first deployed LINE VIPER to establish illegitimate virtual private network (VPN) sessions [T1133] that bypassed all VPN authentication policies. This activity was associated with user accounts that existed but were no longer active within the agency [T1078]. Although this behavior was observed in this incident, threat actors may use other (including fabricated) accounts. LINE VIPER enabled APT actors access to all configuration elements of the victim Firepower device, including administrative credentials, certificates, and private keys [T1082]. Persistence: APT actors deployed FIRESTARTER on the Firepower device before Sept. 25, 2025 (exact date is unknown). Because it was present before patching, FIRESTARTER persisted through remediation and established command and control (C2) channels on the victim Firepower device [T1219]. APT actors leveraged FIRESTARTER to regain access without re-exploiting the original vulnerabilities and deployed LINE VIPER in March 2026. Malware Summary FIRESTARTER is a Linux Executable and Linkable File (ELF) designed to execute on Cisco Firepower and Secure Firewall devices, serving as a C2 channel for remote access and control. The malware achieves persistence by detecting termination signals and relaunching itself, and it can survive firmware updates and device reboots unless a hard power cycle occurs. FIRESTARTER attempts to install a hook—a way to intercept and modify normal operations—within LINA, the device’s core engine for network processing and security functions. This hook enables the execution of arbitrary shell code provided by the APT actors, including the deployment of LINE VIPER. Note: The file CISA obtained for analysis was named lina_cs; filenames may vary, as threat actors can easily modify the name of the malicious file. Malware Functionality Initialization Upon execution, FIRESTARTER accesses its own binary located at /usr/bin/lina_cs on the device [T1036.005] and copies its contents into memory. It then registers a callback function that triggers when the program receives any of the following termination-related signals [T1546.004]: SIGTERM SIGINT SIGQUIT SIGABRT SIGHUP SIGTSTP After copying itself into heap, and updating the signal handlers, the shell executor initiates the following sequential commands: rm /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null cp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null chmod 755 /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null chown‑reference=/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null touch‑r /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST 2>/dev/null rm /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null rm /usr/bin/lina_cs 2>/dev/null These commands delete the modified CSP_MOUNT_LIST file [T1070.004] restoring the original CSP_MOUNT_LIST. Execute permissions are granted to any user, the owner and timestamp are set to match the original [T1070.006], and the temporary file is then deleted. Finally, /usr/bin/lina_cs is deleted. Persistence and Shutdown Task When any of these signals are received or runlevel (6) is reached, the callback function is triggered and first checks whether the /opt/cisco/platform/logs/var/log/ directory exists. If absent, it creates the directory with full read/write/execute permissions [T1222]. The callback then opens /opt/cisco/platform/logs/var/log/svc_samcore.log and writes a copy of itself to this file, which is in a reboot-persistent directory. Next, the callback verifies whether /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST is present on the device. If the file is missing, FIRESTARTER creates it using a special function that can run shell commands [T1059]. After creating the file, the malware runs a series of callback commands (in sequential order) to establish persistence and manage its files: cp /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null chown ‑reference=/opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null touch‑r /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST.tmp 2>/dev/null Append the contents below to /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST mv /opt/cisco/platform/logs/var/log/svc_samcore.log /usr/bin/lina_cs chmod 755 /usr/bin/lina_cs lina_cs & These commands first create a temporary copy of CSP_MOUNT_LIST with the same ownership information and timestamps. A script is appended to CSP_MOUNT_LIST. This script is the persistence mechanism, which moves FIRESTARTER from its staging location, svc_samcore.log, to /usr/bin/lina_cs. It then makes it executable and runs it in the background [T1547]. This sequence ensures persistent execution of the file, even when termination signals are received. All commands redirect any standard error (stderr) messages to /dev/null and hides them from the console [T1564]. Memory Scanning and Hook Installation The process enumerates LINA’s virtual memory map to locate the private read-write (rw-p) segment associated with lina [T1057], which represents the main process’s writable data region. Once identified, this memory segment is parsed using a custom algorithm to locate the XML Handler element table. The algorithm inspects each 0x260-byte region for element IDs. After identifying five element IDs in the correct offset sequence (each separated by 0x260 bytes), it calculates and stores the handler pointer address for the seventeenth element. Shellcode Injection FIRESTARTER scans LINA’s memory to locate the executable (r-xp) segment of libstdc++.so, which corresponds to the C++ standard library’s code section. The malware injects a block of shellcode 0x200 bytes before the end of the library’s text segment, installing the detour for the XML element handler [T1055]. The process then resumes its main loop and continues operating until it detects a reboot runlevel or the termination-related signals. Victim Identification and Stage Loading The FIRESTARTER malware closely mirrors the RayInitiator Cisco ASA bootkit stage 3 deploy path. The injected shellcode is triggered when LINA processes a WebVPN request containing the XML tag with the detoured handler. Within the <group-select> element, the malware searches for a hard-coded 8-byte ASCII string unique to the installation, verifying it against a predefined value embedded in the shellcode. Additionally, a victim-specific ID—another hard-coded 8-byte sequence—is compared against WebVPN request elements until a match is found. Upon successful verification of identification, the next stage of the malware is loaded by copying it into LINA’s memory and invoking mprotect to enable execution of the newly injected code [T1543]. Detection U.S. FCEB Agency Instructions The primary detection method for FIRESTARTER is memory analysis. In accordance with V1: ED 25-03, all U.S. FCEB agencies are required to collect device core dumps and submit them to CISA’s Malware Next Generation (MNG) platform (see Incident Response section), which analyzes core dumps for the presence and behavior of the lina_cs binary. U.S. FCEB agencies should not take further action without first consulting CISA. To preserve evidence, avoid any hard power cycles and other changes (e.g., reboots, patching, configuration changes) before collection and coordination, as these can affect volatile artifacts. Other U.S. and U.K. Recommendations CISA and the NCSC recommend using the following CISA-created YARA rules to detect FIRESTARTER when applied to a disk image or a core dump from a device: To obtain a disk image, open a Cisco Technical Assistance Center (TAC) case. For instructions on obtaining a core dump, see CISA’s Supplemental Direction for ED 25-03. Note: CISA recommends following this Supplemental Direction rather than other open source resources, as APT actors commonly employ anti-forensic techniques. YARA Rules See Table 1 for a list of FIRESTARTER YARA rules. Table 1. YARA Rules FIRESTARTER Rule 1 rule CISA_261290_01 : FIRESTARTER backdoor captures_system_state_data cleans_traces_of_infection fingerprints_host persists_after_system_reboot { meta: author = "CISA Code & Media Analysis" incident = "261290" date = "2026-4-3" last_modified = "20260406_732" actor = "n/a" family = "n/a" capabilities = "captures-system-state-data cleans-traces-of-infection fingerprints-host persists-after-system-reboot" malware_type = "backdoor" tool_type = "unknown" description = "Detects CISCO Firepower FIRESTARTER injector samples" strings: $s1 = { 57 48 C1 EF 0C 48 C1 E7 0C BA 07 00 00 00 48 C7 C6 00 20 00 00 } $s2 = { 2f 6f 70 74 2f 63 69 73 63 6f 2f 70 6c 61 74 66 6f 72 6d 2f 6c 6f 67 73 2f 76 61 72 2f 6c 6f 67 2f } $s3 = { 2f 6f 70 74 2f 63 69 73 63 6f 2f 63 6f 6e 66 69 67 2f 70 6c 61 74 66 6f 72 6d 2f 72 6d 64 62 2f } $s4 = { 2f 76 61 72 2f 72 75 6e 2f 72 75 6e 6c 65 76 65 6c} $s5 = { 2f 70 72 6f 63 2f 25 73 2f 63 6f 6d 6d } $s6 = { 2f 70 72 6f 63 2f 25 64 2f 6d 61 70 73 } $s7 = { 2f 61 73 61 2f 62 69 6e 2f 6c 69 6e 61 } condition: 5 of them } FIRESTARTER Rule 2 rule CISA_261290_02 : FIRESTARTER_shellcode backdoor captures_system_state_data cleans_traces_of_infection fingerprints_host persists_after_system_reboot { meta: author = "CISA Code & Media Analysis" incident = "261290" date = "2026-4-3" last_modified = "20260406_732" actor = "n/a" family = "n/a" capabilities = "captures-system-state-data cleans-traces-of-infection fingerprints-host persists-after-system-reboot" malware_type = "backdoor" tool_type = "unknownk" description = "Detects CISCO Firepower FIRESTARTER_shellcode samples" strings: $1 = { 57 4C 8B 47 18 4D 85 C0 0F 84 C7 01 00 00 49 8B 38 48 85 FF } $2 = { 48 83 C6 08 4C 39 C6 0F 87 7A 01 00 00 4C 8B 0E } $3 = { 48 89 D7 4C 89 CE B9 D0 01 00 F3 A4 48 89 D7 57 48 C1 EF 0C 48 C1 E7 0C } $4 = { 0F 05 58 5F FF E0 90 90 } condition: 3 of them } Sigma Rules Given the nature of this malware, Sigma rules do not offer effective detection because it does not generate observable log events or behavioral anomalies in standard monitoring platforms. Incident Response U.S. FCEB Agencies CISA requires U.S. FCEB agencies to: Refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and submit it through CISA’s Malware Next Generation platform. Report the submission immediately via CISA’s 24/7 Operations Center (contact@cisa.dhs.gov, 1-844-Say-CISA [1-844-729-2472], or CISA’s Incident Reporting System). Identify the activity is related to FIRESTARTER. After incident intake, CISA will provide guidance on next steps. If compromise is confirmed, this may include instructions to physically unplug the device from power to remove FIRESTARTER’s persistence. Organizations should not unplug the device unless directed to do so by CISA. Other U.S. Organizations CISA recommends organizations take the following actions: Although applicable to U.S. FCEB agencies, refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and deploy the provided YARA rules. U.S. organizations can submit core dumps through CISA’s Malware Next Generation platform. If the core dump indicates the presence of FIRESTARTER malware, proceed with steps 3 and 4 below; additionally, activate internal incident response plans to assess potential lateral movement and impact: Unplug the device from all power sources—CISA assesses this is the only method to remove FIRESTARTER’s persistence from a device—then conduct the following steps: Locate the physical device. Unplug the physical device from its power source while the device is still powered on. Note: It is not sufficient to power the device off or reboot it. The device must be entirely removed from all power sources, including duplicate power sources created for redundancy. Leave the device fully disconnected from any power source for one minute. Reconnect the device to its power source and allow it to reboot. Promptly report any detection of FIRESTARTER malware to CISA. U.S. organizations can report to CISA’s 24/7 Operations Center (contact@cisa.dhs.gov, 1-844-Say-CISA [1-844-729-2472], or CISA’s Incident Reporting System). Requests for assistance can also be submitted to CISA via this reporting channel. U.K. Organizations The NCSC recommends U.K. organizations take the following actions: Refer to the Supplemental Direction for ED 25-03 for guidance on running the “show checkheaps” and “show tech-support detail” commands. Ensure to save the full output off the device (preferably to an isolated system). Generate a core dump from the affected Cisco device(s) and deploy the provided YARA rules. If FIRESTARTER is detected, report an incident to the NCSC via https://report.ncsc.gov.uk. After reporting an incident, the NCSC will provide guidance on next steps. If compromise is confirmed, this may include instructions to physically unplug the device from power to remove FIRESTARTER’s persistence. Organizations should not unplug the device unless directed to do so by the NCSC. Mitigations CISA and the NCSC recommend all organizations implement the mitigations below to improve cybersecurity posture on the basis of the threat actors’ activity. These mitigations align with the Cross-Sector Cybersecurity Performance Goals 2.0 (CPG 2.0) developed by CISA and the National Institute of Standards and Technology (NIST). The CPGs provide a minimum set of practices and protections recommended for all organizations. CISA and NIST based the CPGs on existing cybersecurity frameworks and guidance to protect against the most common and impactful threats, tactics, techniques, and procedures. Visit CISA’s CPG 2.0 webpage for more information on the CPGs, including additional recommended baseline protections. Maintain all systems and software with the latest security patches, prioritizing expedited remediation of vulnerabilities listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog [CPG 2.B]. At the time of ED 25-03’s release (Sept. 25, 2025), available patches did not specifically remediate FIRESTARTER; although patching mitigated initial access, it did not eliminate this persistence mechanism. For additional information on software updates that prevent FIRESTARTER’s persistence and for remediation guidance, refer to Cisco’s Security Advisory. Inventory all network edge devices [CPG 2.A], with a specific focus on Cisco devices. Monitor these devices for any suspicious network connections that correlate with the activity described in this report. Monitor and audit activity for all accounts with elevated privileges, including network administrators and service accounts, to detect unauthorized use or anomalous behavior. For example, track and review commands executed by these accounts, and promptly investigate any suspicious activity identified. Apply the principle of least privilege and restrict service accounts to needed permissions only [CPG 3.H]. Regularly rotate passwords for privileged accounts (such as network administrators) and service accounts. Routine password changes invalidate credentials that threat actors may have compromised, forcing them to reestablish access and increasing the likelihood of detection or disruption. While not specific to FIRESTARTER, modernize administrative access controls by implementing TACACS+ over TLS 1.3. This approach encrypts device administration Authentication, Authorization, and Accounting traffic, safeguards administrator and service account credentials, and reduces the risk of interception [CPG 3.K]. See Cisco’s blog, Modernizing TACACS+: Why Full-Session Encryption Matters More Than Ever. Disclaimer CISA and the NCSC do not endorse any commercial entity, product, company, or service, including any entities, products, companies, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favor by CISA or the NCSC. Acknowledgements Cisco contributed to this Malware Analysis Report. Version History April 23, 2026: Initial version. Appendix A: MITRE ATT&CK Techniques See Table 2 through Table 7 all referenced threat actor tactics and techniques in this advisory. For assistance with mapping malicious cyber activity to the MITRE ATT&CK framework, see CISA and MITRE ATT&CK’s Best Practices for MITRE ATT&CK Mapping and CISA’s Decider Tool. Table 2. Initial Access Technique Title ID Use Exploit Public-Facing Application T1190 The APT actors gained access to the victim’s Cisco Firepower device, likely by exploiting CVE-2025-20333 and/or CVE-2025-20362. Table 3. Execution Technique Title ID Use Command and Scripting Interpreter T1059 FIRESTARTER uses a special function to run shell commands that create /opt/cisco/config/platform/rmdb/CSP_MOUNT_LIST if it is missing. FIRESTARTER runs callback commands to manage its files. Table 4. Persistence Technique Title ID Use Create or Modify System Process T1543 FIRESTARTER invokes mprotect to enable execution of newly injected code. Event Triggered Execution: Unix Shell Configuration Modification T1546.004 FIRESTARTER registers a callback function that is automatically triggered when the program receives any of the following termination-related signals: SIGTERM, SIGINT, SIGQUIT, SIGABRT, SIGHUP, or SIGTSTP. Boot or Logon Autostart Execution T1547 Persistence is maintained by modifying a boot-time configuration/mount script so FIRESTARTER runs on startup. External Remote Services T1133 The APT actors used LINE VIPER to establish illegitimate VPN sessions. Valid Accounts T1078 The APT actors used valid user accounts for their illegitimate VPN sessions (the user accounts belonged to former employees). Table 5. Defense Evasion Technique Title ID Use File and Directory Permissions Modification T1222 FIRESTARTER creates the /opt/cisco/platform/logs/var/log/ directory with full read/write/execute permissions. FIRESTARTER uses chown and chmod to modify file permissions. Hide Artifacts: Hidden Users T1564 FIRESTARTER redirects standard error (stderr) messages to /dev/null and hides them from the console. Indicator Removal on Host: File Deletion T1070.004 FIRESTARTER deletes the following files: CSP_MOUNT_LIST, CSP_MOUNT_LIST.tmp, and /usr/bin/lina_cs. Indicator Removal on Host: Timestomp T1070.006 FIRESTARTER uses touch -r to copy timestamps from original files to modified and temporary ones, explicitly to match the original. Masquerading: Match Legitimate Resource Name or Location T1036.005 FIRESTARTER accesses its own binary located at /usr/bin/lina_cs on the victim device. Process Injection T1055 FIRESTARTER injects shellcode into a library’s code section before the start of the text segment. Table 6. Discovery Technique Title ID Use Process Discovery T1057 FIRESTARTER enumerates LINA’s virtual memory map to locate the private read-write (rw-p) segment associated with lina. System Information Discovery T1082 The APT actors used LINE VIPER to access Cisco Firepower device configuration elements, including administrative credentials, certificates, and private keys. Table 7. Command and Control Technique Title ID Use Remote Access Tools T1219 FIRESTARTER is a Linux ELF designed to execute on Cisco Firepower and Secure Firewall devices, serving as a C2 channel for remote access and control.
Browse saved snapshots