        "id": "https://www.cisa.gov/resources-tools/resources/cisa-and-partners-urge-hardening-automatic-tank-gauge-systems",
        "title": "CISA and Partners Urge Hardening Automatic Tank Gauge Systems",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/cisa-and-partners-urge-hardening-automatic-tank-gauge-systems",
        "summary": "<p><a class=\"c-button\" href=\"https://www.cisa.gov/sites/default/files/2026-06/fact-sheet-cisa-and-partners-urge-hardening-automatic-tank-gauge-systems_508c.pdf\">CISA and Partners Urge Hardening Automatic Tank Gauge Systems</a></p>\n<h2><strong>Overview</strong></h2>\n<p>The Cybersecurity and Infrastructure Security Agency (CISA), the Federal Bureau of Investigation (FBI), the National Security Agency (NSA), the Department of Energy (DOE), the Environmental Protection Agency (EPA), the Transportation Security Administration (TSA), the Department of Transportation (DOT), and the U.S. Department of Agriculture (USDA)\u2014hereafter referred to as \u201cthe authoring organizations\u201d\u2014are aware of malicious cyber activity targeting U.S.-based automatic tank gauge (ATG) systems. ATG systems are widely used throughout the <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/energy-sector\">Energy</a>, <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/chemical-sector\">Chemical</a>, <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/food-and-agriculture-sector\">Food and Agriculture</a>, and <a href=\"https://www.cisa.gov/topics/critical-infrastructure-security-and-resilience/critical-infrastructure-sectors/transportation-systems-sector\">Transportation Systems</a> Sectors for automated and remote monitoring of storage tank parameters, including fuel and liquid levels, temperature, and possible leak detection. The authoring organizations urge ATG owners and operators to defend against this malicious activity by securing their ATG systems with strong passwords and by removing them from the internet to reduce public exposure. &nbsp;</p>\n<h2><strong>Threat</strong></h2>\n<p>The recent malicious cyber activity observed by the authoring organizations\u2014which the U.S. government has not yet attributed to a nation-state or threat actor group\u2014involves cyber threat actors compromising internet-exposed ATG systems and subsequently modifying them through command execution. This fact sheet provides insight into probable tactics, techniques, and procedures (TTPs) leveraged by these cyber actors, highlights risk factors associated with such compromises, and provides mitigation guidance and resources to reduce the likelihood of continued malicious activity targeting U.S.-based ATG systems. &nbsp;</p>\n<p>Cyber threat actors may exploit flaws in ATG systems through multiple attack vectors:</p>\n<ul>\n<li><strong>Authentication Bypass and Hardcoded Credentials:</strong> Threat actors gain unauthorized access to device management interfaces. &nbsp;</li>\n<li><strong>OS Command Execution and Structured Query Language (SQL) Injection:</strong> Threat actors execute arbitrary code and manipulate underlying databases. &nbsp;</li>\n<li><strong>Privilege Escalation:</strong> Threat actors achieve full administrator privileges over the device application and operating system.</li>\n</ul>\n<p>Should a cyber threat actor exploit these vulnerabilities and compromise an ATG system, they could disrupt or manipulate the below critical functions by interfacing directly with the tank management as though they possessed legitimate physical access to the system console. The cyber threat actors could:</p>\n<ul>\n<li><strong>Alter system(s) attributes</strong>, such as network settings, product identifiers, tank volumes, and pump controls;</li>\n<li><strong>Compound operational malfunctions</strong>; components operating incorrectly could create a denial of view condition of tank fill levels, which could cause permanent damage to the tank system\u2019s critical function;</li>\n<li><strong>Disable system alerts</strong>, reducing an operator\u2019s ability to detect and mitigate system issues increases the risk of environmental or physical hazards from incidents such as leaks or relay failures.</li>\n</ul>\n<h2><strong>Mitigations</strong></h2>\n<p>The authoring organizations recommend ATG owners immediately implement the following recommendations:</p>\n<ol>\n<li><strong>Eliminate public internet exposure: Do not expose the ATG serial port (e.g., default TCP port 8001, 9001, or 10001), or other applicable web interfaces, directly to the internet</strong>. If remote access to the port is necessary, consider the following options:<br>\n<ol type=\"a\">\n<li><strong>Restrict access</strong>: Use a firewall, access control list (ACL), or virtual private network (VPN) to restrict access.</li>\n</ol>\n</li>\n<li><strong>Enforce Credential Security: Change any default passwords immediately</strong> [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#ChangingDefaultPasswords3A\">CPG 3.A</a>] and implement strong, unique security codes and administrative credentials for all interfaces, including the serial port. Further, implement phishing-resistant multifactor authentication wherever feasible [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#ImplementMultifactorAuthentication3F\">CPG 3.F</a>]. If unfamiliar with these procedures, contact your ATG service provider for assistance.</li>\n<li><strong>Apply Patches</strong>: Where possible, work with certified ATG service providers, if available, to verify compliance, update software, and apply the latest security patches from the manufacturer. &nbsp;</li>\n<li><strong>Monitor and Report</strong>: Organizations should actively monitor networks for unauthorized access.<br>\n<ol type=\"a\">\n<li><strong>Enable logging and audit and monitor logs</strong> to identify exposures of ATG device interfaces, unauthorized connections, suspicious alarms, alarm threshold modifications, tank label changes, and other system modifications [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#MaintainLogCollectionStorage3Q\">CPG 3.Q</a>].</li>\n<li><strong>Report suspected incidents</strong> promptly to the CISA <a href=\"https://www.cisa.gov/topics/cyber-threats-and-advisories/information-sharing/cyber-incident-reporting-critical-infrastructure-act-2022-circia/voluntary-cyber-incident-reporting\">portal</a>.</li>\n</ol>\n</li>\n<li><strong>Engage your third-party service providers</strong> to adopt CISA, FBI, EPA, and DOE\u2019s <a href=\"https://www.cisa.gov/sites/default/files/2025-05/fact-sheet-primary-mitigations-to-reduce-cyber-threats-to-operational-technology-508c.pdf\">Primary Mitigations to Reduce Cyber Threats to Operational Technology</a> [<a href=\"https://www.cisa.gov/cybersecurity-performance-goals-2-0-cpg-2-0#ManageRisksfromManagedServiceProviders1E\">CPG 1.E</a>].</li>\n</ol>\n<h2><strong>Resources</strong></h2>\n<p>The authoring organizations recommend ATG owners and operators review the following resources and implement suggested mitigations, where possible, to enhance their security posture.</p>\n<ol>\n<li>For more information on mitigating cyber threat activity targeting internet-exposed OT and ICS, see CISA, FBI, EPA, and DOE\u2019s <a href=\"https://www.cisa.gov/sites/default/files/2025-05/fact-sheet-primary-mitigations-to-reduce-cyber-threats-to-operational-technology-508c.pdf\">Primary Mitigations to Reduce Cyber Threats to Operational Technology</a> fact sheet.</li>\n<li>For more information on vulnerabilities affecting ATG systems, see <a href=\"https://www.bitsight.com/blog/critical-vulnerabilities-discovered-automated-tank-gauge-systems\" target=\"_blank\">Critical Vulnerabilities Discovered in Automated Tank Gauge Systems</a>.<a href=\"#note1\"><sup>1</sup></a></li>\n<li>For ways to identify and remove internet-accessible assets, see CISA\u2019s <a href=\"https://www.cisa.gov/resources-tools/resources/exposure-reduction\">Internet Exposure Reduction Guidance</a> web page. &nbsp;</li>\n<li>For more information about how organizations should design, secure, and manage connectivity in OT, see <a href=\"https://www.ncsc.gov.uk/sites/default/files/documents/ncsc-secure-connectivity-for-operational-technology.pdf\" target=\"_blank\">Secure connectivity principles for Operational Technology (OT)</a>. &nbsp;</li>\n</ol>\n<h2><strong>Contact Information</strong></h2>\n<p>The authoring organizations recommend U.S. organizations report suspicious or criminal activity related to information provided in this fact sheet.</p>\n<ul>\n<li><strong>CISA</strong>: Contact CISA\u2019s 24/7 Operations Center via <a href=\"mailto:report@cisa.gov\" target=\"_blank\">report@cisa.gov</a> or 888-282-0870.\n<ul>\n<li>When available, please include the following information regarding the incident: date, time, and location of the incident; type of activity; number of people affected; type of equipment used for the activity; the name of the submitting company or organization; and a designated point of contact.</li>\n<li>For more information on reporting a cyber incident, refer to CISA\u2019s <a href=\"https://www.cisa.gov/topics/cyber-threats-and-advisories/information-sharing/cyber-incident-reporting-critical-infrastructure-act-2022-circia/voluntary-cyber-incident-reporting\">Voluntary Cyber Incident Reporting</a> web page.</li>\n</ul>\n</li>\n<li><strong>FBI</strong>: File a complaint with the Internet Crime Complaint Center (IC3) at\u202f<a href=\"https://www.ic3.gov/\" target=\"_blank\">www.ic3.gov</a>. When available, include the following incident information: date, time, and location of the incident; type of activity; number of people affected; type of equipment used for the activity; the name of the submitting organization; and designated point of contact.</li>\n<li><strong>EPA</strong>: Contact EPA\u2019s Office of National Security via <a href=\"mailto:ONS-OC@epa.gov\" target=\"_blank\">ONS-OC@epa.gov</a>.</li>\n<li><strong>DOE</strong>: Entities required to report incidents to DOE should follow established reporting requirements, as appropriate. For other energy sector inquiries, contact <a href=\"mailto:EnergySRMA@hq.doe.gov\" target=\"_blank\">EnergySRMA@hq.doe.gov</a>.</li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. The authoring organizations do not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favor by the authoring organizations.&nbsp;</p>\n<h2><strong>Notes</strong></h2>\n<p><a class=\"ck-anchor\" id=\"note1\">1</a> Pedro Umbelino, \u201cCritical Vulnerabilities Discovered in Automated Tank Gauge Systems,\u201d <em>Bitsight,</em> October 11, 2023,&nbsp;<a href=\"https://www.bitsight.com/blog/critical-vulnerabilities-discovered-automated-tank-gauge-systems\" target=\"_blank\">bitsight.com/blog/critical-vulnerabilities-discovered-automated-tank-gauge-systems</a>.</p>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/cisa-and-partners-urge-hardening-automatic-tank-gauge-systems\">CISA PRODUCT SURVEY</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Tue, 02 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 02 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/02/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/02/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-0492\" target=\"_blank\">CVE-2022-0492</a> Linux Kernel Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-48595\" target=\"_blank\">CVE-2025-48595</a> Android Framework Integer Overflow Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 02 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 02 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-21182\" target=\"_blank\">CVE-2024-21182</a> Oracle WebLogic Server Unspecified Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vectors for malicious cyber actors and poses significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 01 Jun 26 12:00:00 +0000",
        "last_updated": "Mon, 01 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-0257\" target=\"_blank\">CVE-2026-0257</a> Palo Alto Networks PAN-OS Authentication Bypass Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vectors for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 29 May 26 12:00:00 +0000",
        "last_updated": "Fri, 29 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-06",
        "title": "KMW CCTV Security Cameras",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability may grant full unauthorized access to camera feeds and settings.</strong></p>\n<p>The following versions of KMW CCTV Security Cameras are affected:</p>\n<ul>\n<li>KM-IP521 IPCAM_V4.04.91.230307</li>\n<li>KM-IP421 IPCAM_V4.04.53.210416&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>KMW</td>\n<td>KMW CCTV Security Cameras</td>\n<td>Unverified Password Change</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Government Services and Facilities, Critical Manufacturing, Financial Services, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Romania</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-5386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is vulnerable to a critical unauthenticated password reset. This flaw allows an attacker to remotely reset the administrator password to a known value without authentication, granting full access to the camera feeds and settings.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-5386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>KMW CCTV Security Cameras</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>KMW</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>KMW KM-IP521: IPCAM_V4.04.91.230307, KMW KM-IP421: IPCAM_V4.04.53.210416</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>KMW has issued a firmware update to address this vulnerability. The firmware update can be found at https://main.kmw.ro/pub/Firmware/521_421.zip.<br><a href=\"https://main.kmw.ro/pub/Firmware/521_421.zip\">https://main.kmw.ro/pub/Firmware/521_421.zip</a></p>\n<p><strong>Vendor fix</strong><br>KM-IP421 - will lose the cloud authorization after this update so users will need to contact customer support to re-authorize the P2P connection.</p>\n<p><strong>Mitigation</strong><br>KMW recommends connecting surveillance equipment on a separate network, allow only specific devices access to the internet, check for firmware updates regularly, and use cloud connections responsibly.</p>\n<p><strong>Mitigation</strong><br>If there are any issues customers are encouraged to contact KMW directly.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/620.html\">CWE-620 Unverified Password Change</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Reporter Name(s): Souvik Kandar</li>\n<li>reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-03",
        "title": "ABB EIBPORT",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. A firmware update is available that resolves these privately reported vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could access sensitive information stored inside the device and can change the configuration of the device.</strong></p>\n<p>The following versions of ABB EIBPORT are affected:</p>\n<ul>\n<li>EIBPORT V3 KNX (2CLA963710W1001) &lt;3.9.2</li>\n<li>EIBPORT V3 KNX (2CSM256242R2001) &lt;3.9.2</li>\n<li>EIBPORT V3 KNX GSM (2CLA963720W1001) &lt;3.9.2</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8</td>\n<td>ABB</td>\n<td>ABB EIBPORT</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-22291</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability allows the successful attacker to receive a copy of the session id.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-22291\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB EIBPORT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EIBPORT V3 KNX (2CLA963710W1001) Version &lt;3.9.2, EIBPORT V3 KNX (2CSM256242R2001) Version &lt;3.9.2, EIBPORT V3 KNX GSM (2CLA963720W1001) version &lt; 3.9.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>ABB recommends that customers apply the update at the earliest convenience.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Psytester reported this vulnerability to ABB.</li>\n</ul>\n<hr>\n<h2>Mitigating factors</h2>\n<p>Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. More information on recommended practices can be found in the documents listed in the Reference section.</p>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerability? The session management of vulnerable FW versions of EIBPORT, fails to maintain a secure session management. What is EIBPORT? EIBPORT is a building management system allowing to automate buildings based on the KNX standards. What might an attacker use the vulnerability to do? An attacker who successfully exploited these vulnerabilities can gain access to the EIBPORT device without authenticating her-, himself. Could the vulnerability be exploited remotely? No, recommended practices include that building automation control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. Following these best practices, an attacker cannot exploit the vulnerability remotely. Unfortunately, ABB became aware that some customers have commissioned EIBPORT not according to these best practices but have made the IP address to the device accessible over the Internet or other untrusted networks. ABB emphasizes that this configuration is against the intended use of the system. Can functional safety be affected by an exploit of this vulnerability? No. EIBPORT is not designed as a functional safety device. What does the update do? The update removes the vulnerabilities by modifying the way that the device firmware verifies login credentials and token or session identifiers. Furthermore, it hardens the product configuration wherever possible. When this security advisory was issued, had this vulnerability been publicly disclosed? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A7808 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-10-07</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-10-07</td>\n<td>1</td>\n<td>Initial version</td>\n</tr>\n<tr>\n<td>2026-05-28</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT 9AKK108471A7808 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-02",
        "title": "Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in an attacker gaining administrator access to the device.</strong></p>\n<p>The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter are affected:</p>\n<ul>\n<li>USR-W610 RS232/485 to Wi-Fi/Ethernet Converter 7.03T.07</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Jinan USR IOT Technology Limited (PUSR)</td>\n<td>Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter</td>\n<td>Use of Hard-coded Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-7786</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The device firmware contains plaintext administrative credentials embedded in the firmware image. These credentials can be extracted through firmware analysis and used to authenticate to device services.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-7786\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Jinan USR IOT Technology Limited (PUSR)</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter: 7.03T.07</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Jinan USR IOT Technology Limited (PUSR) did not respond to CISA's attempts at coordination. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Arun Mane and Omkar Mali reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-04",
        "title": "ABB Busch-Welcome 2 Wire Door Opener Actuator",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed</strong></p>\n<p>The following versions of ABB Busch-Welcome 2 Wire Door Opener Actuator are affected:</p>\n<ul>\n<li>Switch Actuator 4 DU vers:all/*&nbsp;</li>\n<li>Switch actuator, door/light 4 DU vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.8</td>\n<td>ABB</td>\n<td>ABB Busch-Welcome 2 Wire Door Opener Actuator</td>\n<td>Active Debug Code</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7705</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Authentication bypass due to compatibility mode enabled by default</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7705\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Busch-Welcome 2 Wire Door Opener Actuator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Switch Actuator 4 DU -83330 - All Versions, Switch actuator, door/light 4 DU -83330-500 - All Versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The following actions need to be executed on premise where the respective Busch-Welcome\u00ae System is installed: \u2022 While the Busch-Welcome\u00ae System is in operation, toggle the mode switch on the product from \u201cDoor-Open\u201d - to \u201cLight\u201d \u2013 Mode, wait one second and switch back to \u201cDoor-Open\u201d - Mode. \u2022 Restart the Busch-Welcome\u00ae System with a Power reset (mains power off and on again). By executing the above steps, the system will recalibrate itself during boot up and will correct the misconfiguration automatically. ABB recommends that customers apply the above listed actions at the earliest convenience.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/489.html\">CWE-489 Active Debug Code</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>ABB recommends double check the system handbook of a Busch-Welcome\u00ae two wire system regarding security advises for the correct installation.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A4556 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-07-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-07-21</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-28</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT 9AKK108471A4556 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-148-01",
        "title": "Fourth Frontier Frontier X Mobile Application, Frontier X2",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-148-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-148-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm.</strong></p>\n<p>The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected:</p>\n<ul>\n<li>Frontier X Android application vers&lt;v15.0.0</li>\n<li>Frontier X IOS application vers&lt;v25.0.0</li>\n<li>Frontier X2 vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Fourth Frontier</td>\n<td>Fourth Frontier Frontier X Mobile Application, Frontier X2</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-5768</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-5768\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Fourth Frontier Frontier X Mobile Application, Frontier X2</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Fourth Frontier</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Fourth Frontier Frontier X Android application: &lt;v15.0.0, Fourth Frontier Frontier X IOS application: &lt;v25.0.0, Fourth Frontier Frontier X2: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance. https://fourthfrontier.com/pages/contact-usl.<br><a href=\"https://fourthfrontier.com/pages/contact-us\">https://fourthfrontier.com/pages/contact-us</a></p>\n<p><strong>Mitigation</strong><br>Frontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Shakir Zari and Jerin Sunny reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-07",
        "title": "Schneider Electric EcoStruxure Machine Expert HVAC",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcostruxureTM Machine Expert HVAC product. The [EcostruxureTM Machine Expert HVAC](https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC/) product is a programming software for Modicon M171-M172 logic controllers. Failure to apply the remediation provided below may risk in revealing sensitive information, which could result in disclosing protected source code, leading to loss of confidentiality.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01) are affected:</p>\n<ul>\n<li>Ecostruxure\u2122 Machine Expert HVAC vers&lt;1.10.0</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01)</td>\n<td>Cleartext Storage of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-6332</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revealing protected source code and loss of confidentiality, when an authorized attacker accesses the source code for editing or compiling it.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-6332\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ecostruxure\u2122 Machine Expert HVAC Versions prior to 1.10.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 1.10.0 of Ecostruxure\u2122 Machine Expert HVAC includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/&nbsp;<br><a href=\"https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/\">https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-12</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-05-28</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-132-01 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-01",
        "title": "MacGregor Voyage Data Recorder (VDR) G4e",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could result in an attacker gaining administrator access to the device.</strong></p>\n<p>The following versions of MacGregor Voyage Data Recorder (VDR) G4e are affected:</p>\n<ul>\n<li>MacGregor Voyage Data Recorder (VDR) G4e &lt;V5.250</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>Danelec</td>\n<td>MacGregor Voyage Data Recorder (VDR) G4e</td>\n<td>Use of Default Credentials, Insufficiently Protected Credentials, Use of Password Hash With Insufficient Computational Effort, Use of Hard-coded Credentials, Files or Directories Accessible to External Parties</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Denmark</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-42941</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The VDR device includes a default username and password, with no enforced password change.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42941\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>MacGregor Voyage Data Recorder (VDR) G4e</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Danelec</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Danelec MacGregor Voyage Data Recorder (VDR) G4e: &lt;V5.250</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact<br><a href=\"https://www.danelec.com/contact\">https://www.danelec.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1392.html\">CWE-1392 Use of Default Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-42951</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authenticated user can download a backup of the device which includes account data and password hashes.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42951\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>MacGregor Voyage Data Recorder (VDR) G4e</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Danelec</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Danelec MacGregor Voyage Data Recorder (VDR) G4e: &lt;V5.250</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact<br><a href=\"https://www.danelec.com/contact\">https://www.danelec.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-44611</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Passwords are stored with a hashing method which limits password length and is susceptible to brute force attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-44611\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>MacGregor Voyage Data Recorder (VDR) G4e</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Danelec</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Danelec MacGregor Voyage Data Recorder (VDR) G4e: &lt;V5.250</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact<br><a href=\"https://www.danelec.com/contact\">https://www.danelec.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/916.html\">CWE-916 Use of Password Hash With Insufficient Computational Effort</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-42929</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The device includes default accounts with hard-coded credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42929\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>MacGregor Voyage Data Recorder (VDR) G4e</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Danelec</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Danelec MacGregor Voyage Data Recorder (VDR) G4e: &lt;V5.250</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact<br><a href=\"https://www.danelec.com/contact\">https://www.danelec.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40425</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The administrator account for the web interface can directly edit sensitive files related to authentication, potentially changing the root password.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40425\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>MacGregor Voyage Data Recorder (VDR) G4e</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Danelec</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Danelec MacGregor Voyage Data Recorder (VDR) G4e: &lt;V5.250</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact<br><a href=\"https://www.danelec.com/contact\">https://www.danelec.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:L\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Andrew Tierney of Pen Test Partners reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-05",
        "title": "CP Plus 8 Ch. Network Video Recorder",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability allows an attacker's malicious script to execute in the browser of any authenticated user or administrator who accesses the affected interface. This could lead to compromise of user sessions, execution of unauthorized actions with the victim's privileges, exposure or manipulation of sensitive data, and degradation of overall system integrity.</strong></p>\n<p>The following versions of CP Plus 8 Ch. Network Video Recorder are affected:</p>\n<ul>\n<li>CP-UNR-108F1 Hardware V1.0</li>\n<li>CP-UNR-108F1 Web V3.2.7.128806&nbsp;</li>\n<li>CP-UNR-108F1 System V4.001.00AT009.0.R&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.4</td>\n<td>CP Plus</td>\n<td>CP Plus 8 Ch. Network Video Recorder</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Emergency Services</li>\n<li><strong>Countries/Areas Deployed: </strong>India, Nepal, United Arab Emirates, Gambia</li>\n<li><strong>Company Headquarters Location: </strong>India</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-6824</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A stored Cross-Site Scripting (XSS) vulnerability exists in certain 1xxx series NVR devices due to insufficient sanitization of user-supplied input in specific functional modules. Attackers can inject malicious scripts, which are then persistently stored on the device backend. When administrators or users access affected pages, the stored scripts are executed in their browsers, leading to potential session hijacking, unauthorized actions, or data theft.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-6824\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CP Plus 8 Ch. Network Video Recorder</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CP Plus</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CP Plus CP-UNR-108F1 Hardware: V1.0, CP Plus CP-UNR-108F1 Web: V3.2.7.128806, CP Plus CP-UNR-108F1 System: V4.001.00AT009.0.R</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CP Plus recommends updating the firmware on the device to the latest firmware version.</p>\n<p><strong>Mitigation</strong><br>CP-UNR-AxxxMars_PN_15_Q_00_V1.00.14.01.T.260326 which can be downloaded at https://drive.google.com/file/d/1Ctxdp55UtlrQY7CSepkImM9zFgdcuCyL/view<br><a href=\"https://drive.google.com/file/d/1Ctxdp55UtlrQY7CSepkImM9zFgdcuCyL/view\">https://drive.google.com/file/d/1Ctxdp55UtlrQY7CSepkImM9zFgdcuCyL/view</a></p>\n<p><strong>Mitigation</strong><br>For firmware access and upgrade instructions, please contact support at:</p>\n<p><strong>Mitigation</strong><br>Phone: +91-8800952952</p>\n<p><strong>Mitigation</strong><br>Email: support@cpplusworld.com<br><a href=\"mailto:support@cpplusworld.com\">mailto:support@cpplusworld.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jithin Nambiar J reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-08",
        "title": "XCharge C6",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-148-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to gain administrator rights or execute code on the affected device.</strong></p>\n<p>The following versions of XCharge C6 are affected:</p>\n<ul>\n<li>C6</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>XCharge</td>\n<td>XCharge C6</td>\n<td>Download of Code Without Integrity Check, Stack-based Buffer Overflow, Initialization of a Resource with an Insecure Default</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9037</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A firmware update mechanism in the affected charging controller fails to validate the authenticity of firmware packages delivered through the device's management interface. Because cryptographic signatures are not verified, an attacker with the ability to interfere with or impersonate the management channel could cause the device to install an unauthorized firmware package. This condition could allow execution of unauthorized code with high privileges on the device,</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9037\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>XCharge C6</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>XCharge</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>XCharge C6: &lt;May_22_2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact<br><a href=\"https://www.xcharge.com/contact\">https://www.xcharge.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/494.html\">CWE-494 Download of Code Without Integrity Check</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9038</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A stack-based buffer overflow vulnerability in the charging controller's signal-processing logic allows an attacker with physical access to the charging interface to supply message fields that exceed expected bounds. Because the input is not sufficiently validated, memory corruption may occur, which can lead to execution of unauthorized code with elevated privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9038\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>XCharge C6</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>XCharge</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>XCharge C6: &lt;May_22_2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact<br><a href=\"https://www.xcharge.com/contact\">https://www.xcharge.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9039</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A configuration weakness in the device's remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9039\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>XCharge C6</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>XCharge</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>XCharge C6: &lt;May_22_2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact<br><a href=\"https://www.xcharge.com/contact\">https://www.xcharge.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1188.html\">CWE-1188 Initialization of a Resource with an Insecure Default</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Lionel R. Saposnik of SaiFlow reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-28</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/28/supply-chain-compromises-impact-nx-console-and-github-repositories",
        "title": "Supply Chain Compromises Impact Nx Console and GitHub Repositories",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/28/supply-chain-compromises-impact-nx-console-and-github-repositories",
        "summary": "<p>CISA is prioritizing the response to multiple emerging software supply chain intrusion campaigns targeting developer ecosystems Continuous Integration/Continuous Development (CI/CD) pipelines. These recent incidents, including the GitHub compromise via a malicious Nx Console Visual Studio Code (VS Code) extension and the \u201cMegalodon\u201d supply chain intrusion campaign, demonstrate how cyber threat actors are abusing tools and processes that support enterprise, cloud, and DevOps environments\u2014specifically CI/CD pipelines, code extensions and workflows.&nbsp;</p>\n<p>Threat actors leveraged a prior compromise of Nx developer systems to compromise a GitHub employee\u2019s device&nbsp;through a poisoned third-party VS Code extension, resulting in unauthorized access and exfiltration of internal GitHub repositories. The malicious extension version (18.95.0) was distributed through VS Code\u2019s automatic update mechanism, meaning systems with Nx Console previously installed may have received the malicious build without developers taking any manual installation action. GitHub released a <a href=\"https://github.com/nrwl/nx-console/security/advisories/GHSA-c9j4-9m59-847w\" target=\"_blank\">security advisory</a> on this activity, and <a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48027\" target=\"_blank\">CVE-2026-48027</a> has been assigned to the malicious version of Nx Console and added to <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">CISA\u2019s Known Exploited Vulnerabilities (KEV) Catalog</a>.</p>\n<p>Additionally, in a campaign known as \u201cMegalodon,\u201d a cyber threat actor injected malicious GitHub Action workflows to harvest CI/CD secrets, cloud credentials, and tokens, impacting both development and deployment pipelines in public GitHub repositories.</p>\n<p>CISA urges organizations to implement the following recommendations to detect and remediate a potential compromise:</p>\n<ul>\n<li>Monitor and audit workflow files and contributor activity for suspicious pull requests and direct commits, particularly those authored by automated accounts.</li>\n<li>Revert unauthorized changes, especially from automated accounts, e.g., <code>build-bot</code>, <code>auto-ci</code>, <code>ci-bot</code>, <code>pipeline-bot</code> and especially those made after May 18, 2026.</li>\n</ul>\n<p>If your organization discovers a compromise resulting from previously compromised GitHub or Nx Console software, CISA recommends the following steps:</p>\n<ul type=\"square\">\n<li>Conduct a forensics review of CI/CD logs, cloud audit trails, and affected developer machines.&nbsp;</li>\n<li>Rotate/revoke all secrets including: all credentials, tokens, and secrets accessible to CI/CD pipelines, including API keys, cloud provider credentials (Amazon Web Services, Google Cloud Platform, Microsoft Azure), SSH keys, Docker/npm/PyPI/Vault/Terraform/Kubernetes tokens, GitHub/GitLab/Bitbucket tokens, and developer or pipeline secrets.&nbsp;</li>\n<li>Notify proper stakeholders if necessary.</li>\n</ul>\n<p>CISA recommends the following best practices for using package repos:</p>\n<ul type=\"square\">\n<li>Wait at least three hours before pulling a new package. This gives the software community time to identify suspicious or malicious packages before they are widely downloaded.&nbsp;</li>\n<li>Pin software to specific trusted versions. Pinning software prevents pulling a malicious or unscreened package during the build process.&nbsp;</li>\n<li>Only pull packages from known and trusted sources. Relying on known and trusted sources reduces the likelihood of downloading a package that has been maliciously forked.&nbsp;</li>\n</ul>\n<p>See the following resources for additional guidance on these compromises:</p>\n<ul type=\"square\">\n<li>GitHub: <a href=\"https://github.blog/security/investigating-unauthorized-access-to-githubs-internal-repositories/\" target=\"_blank\">Investigating unauthorized access to GitHub-owned repositories</a></li>\n<li>Nx:&nbsp;<a href=\"https://nx.dev/blog/nx-console-v18-95-0-postmortem\" target=\"_blank\">Postmortem: Nx Console v18.95.0 supply-chain compromise</a></li>\n<li>Ox Security: <a href=\"https://www.ox.security/blog/megalodon-cicd-malware-github/\" target=\"_blank\">Megalodon: CI/CD Malware Spreading Across GitHub Repositories</a></li>\n<li>StepSecurity: <a href=\"https://www.stepsecurity.io/blog/nx-console-vs-code-extension-compromised#indicators-of-compromise\" target=\"_blank\">Nx Console VS Code Extension Compromised</a>&nbsp;</li>\n<li>SafeDep: <a href=\"https://safedep.io/megalodon-mass-github-repo-backdooring-ci-workflows/\" target=\"_blank\">Megalodon: Mass GitHub Repo Backdooring via CI Workflows</a></li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.\u202f&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 28 May 26 12:00:00 +0000",
        "last_updated": "Thu, 28 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/27/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Three Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/27/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added&nbsp;three&nbsp;new vulnerabilities&nbsp;to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-8398\" target=\"_blank\">CVE-2026-8398</a>&nbsp;Daemon Tools Lite Embedded Malicious Code Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-45321\" target=\"_blank\">CVE-2026-45321</a>&nbsp;TanStack&nbsp;Unspecified Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48027\" target=\"_blank\">CVE-2026-48027</a>&nbsp;Nx Console Embedded Malicious Code Vulnerability</li>\n</ul>\n<p>These&nbsp;types&nbsp;of vulnerabilities are&nbsp;frequent attack vectors&nbsp;for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a>&nbsp;for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing&nbsp;timely&nbsp;remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>&nbsp;as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 27 May 26 12:00:00 +0000",
        "last_updated": "Wed, 27 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-06",
        "title": "ABB LVS MConfig",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB became aware of an internally discovered vulnerability in the MConfig product versions listed as affected in the advisory. An attacker with access to local networks who successfully exploits vulnerability could have access to application\u2019s sensitive information. ABB strongly advises customers to update MConfig with latest software version.</strong></p>\n<p>The following versions of ABB LVS MConfig are affected:</p>\n<ul>\n<li>LVS &lt;=1.4.9.21</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.4</td>\n<td>ABB</td>\n<td>ABB LVS MConfig</td>\n<td>Cleartext Storage of Sensitive Information in Memory</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-9970</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>During the runtime of the MConfig Software application, an attacker can export the memory dump file into the operating system. If passwords are stored in plain text in memory, they will be included in these dump files. If such dump files are mishandled, attackers could obtain them and extract the passwords.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-9970\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB LVS MConfig</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>MConfig Version &lt;=1.4.9.21</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The vulnerability is resolved in the following product versions: MConfig version 1.4.9.22 ABB advises users to update their devices to the latest software version. Additionally, ABB recommends implementing defensive measures to reduce the risk of vulnerability exploitation, as outlined in the product instruction manual. Please refer to the section \u201cMitigation factors\u201d for more information</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/316.html\">CWE-316 Cleartext Storage of Sensitive Information in Memory</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H/E:P/RL:O/RC:C/CR:L/IR:L/AR:L\">CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H/E:P/RL:O/RC:C/CR:L/IR:L/AR:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third-party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. In case customer cannot upgrade the firmware or it is not feasible then please immediately apply mitigating factors mentioned in \u201cGeneral security recommendations\u201d.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerability? The vulnerability is caused by code defect allowing the attacker to extract the sensitive information such as user credentials from memory dump of the application. Please refer to Vulnerability severity and details for further details. What is MConfig ? MConfig is the parameterizing software for ABB LV switchgear components such as motor and feeder controller, operation panel, temperature monitoring solutions and protocol converter. The components are physically installed in a low voltage switchgear located in switch rooms that require authority to access. To run this software on a host machine (computer), the operating system should be Win11 or later version. What might an attacker use the vulnerability to do? If the mentioned vulnerability has been successfully exploited by an attacker, this could allow the attacker to extract sensitive information such as user credentials. With user credentials and access to a host machine with MConfig installed, and access to the switch room with components installed in a switchgear, the attacker can modify the setting of the components potentially compromising its correct operation. How could an attacker exploit vulnerability? An attacker with host machine physical access could, after a user log into MConfig, exploit a vulnerability by exporting a memory dump during runtime, potentially exposing the user's password. Could vulnerability be exploited remotely? The vulnerability can only be exploited if an attacker has physical access to the host machine with MConfig software. What does the update do? MConfig version V1.4.9.22 update has fix for the vulnerability mentioned in Vulnerability severity and details section. The measures below were implemented to fix the vulnerability: \u2022 Clear any authentication-related memory data after a successful login. \u2022 Hash the passwords in SHA256</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 4TZ00000006008 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-10-08</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-10-08</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT 4TZ00000006008 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-04",
        "title": "ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>An update is available that resolves a vulnerability identified by B&amp;Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited this vulnerability could cause the product to stop.</strong></p>\n<p>The following versions of ABB B&amp;R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM) are affected:</p>\n<ul>\n<li>Automation Runtime &lt;6.3</li>\n<li>Automation Runtime &lt;Q4.93</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>B&amp;R</td>\n<td>ABB B&amp;R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)</td>\n<td>Improper Resource Locking</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-3450</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Improper Resource Locking vulnerability in the SDM component of B&amp;R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service conditions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-3450\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automation Runtime &lt;6.3, Automation Runtime &lt;Q4.93</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in Automation Runtime versions 6.3 and Q4.93. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not in-tended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&amp;R recommends applying the update at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/413.html\">CWE-413 Improper Resource Locking</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H/E:U/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H/E:U/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>Deactivate the vulnerable component The SDM is deactivated by default on Automation Runtime version &gt;=6.0. For Automation Runtime versions &lt;6.0, the SDM can be deactivated in the Automation Studio project. Please refer to Automation Help GUID 1d915d67-07f7-4034-a472-c204b5cabbfe for further guidance. Access to the System Diagnostic Manager (SDM) shall be restricted to trusted personnel through appropriate external security measures. If SDM is required solely for maintenance purposes, it should be enabled or access granted only for the minimum time necessary to perform the task. Limit accessibility B&amp;R recommends in general to configure the HTTP protocol over TLS (HTTPS). Customers may restrict access to the webserver by configuring mutual TLS (mTLS) in the Automation Studio project (Option \u201cValidate SSL communication partner\u201d). Be aware that configuring mTLS would impact also other applications using the AR webserver (e.g. mapp View). Please refer to Automation Help GUID 01ced6c0-28ef-4aaa-bd05-2442b971859c to learn more about the TLS Configuration in Automation Studio. In addition, accessibility of the webserver can be limited to trusted IP addresses using the Automation Runtime host-based firewall. Please refer to Automation Help GUID 75b8994b-f97a-4e0f-8278-43c7a737e65f for details. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerability? The vulnerabilities are caused by improper resource locking. What is System Diagnostics Manager (SDM)? System Diagnostics Manager (SDM) is a webpage available over the Automation Runtime Webserver, showing key diagnostic information of the running controller What is Automation Runtime (AR)? B&amp;R Automation Runtime is a middleware system enabling customers to run applications on B&amp;R target systems. What might an attacker use the vulnerability to do? An attacker who successfully exploited these vulnerabilities could cause the affected system node to stop. How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had this vulnerability been publicly disclosed? No, B&amp;R discovered the vulnerabilities through its own security analysis. When this security advisory was issued, had B&amp;R received any reports that this vulnerability was being exploited? No, B&amp;R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA25P002 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-10-07</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-10-07</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT SA25P002 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-05",
        "title": "ABB Ability Camera Connect",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of public reports of vulnerabilities in a 3rd party component VLC media player Version 2.2.4 which was delivered together with the installation package of Camera Connect Version 1.5.0.14 and below. An update is available that resolves a privately reported outdated 3rd party component with vulnerabilities in the product versions listed as affected in this advisory. An attacker who successfully exploited any of these vulnerabilities in the 3rd party component could potentially compromise the system in different ways.</strong></p>\n<p>The following versions of ABB Ability Camera Connect are affected:</p>\n<ul>\n<li>Ability Camera Connect vers:intdot/&lt;=1.5.0.14, 1.5.0.15</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>ABB</td>\n<td>ABB Ability Camera Connect</td>\n<td>Heap-based Buffer Overflow, Integer Underflow (Wrap or Wraparound), Out-of-bounds Write, Uncontrolled Search Path Element, Integer Overflow or Wraparound, Off-by-one Error, Out-of-bounds Read, Double Free, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Commercial Facilities, Communications, Critical Manufacturing, Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-46461</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>VLC media player 3.0.20 and earlier is vulnerable to denial of service through an integer overflow which could be triggered with a maliciously crafted mms stream (heap based overflow). If successful, a malicious third party could trigger either a crash of VLC or an arbitrary code execution with the target user's privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-46461\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The VLC-based component operates solely within completely isolated environments without internet access or any connectivity to external networks. Consequently: \u2022 No exposure to untrusted MMS streams: The integer overflow vulnerability relies on handling a maliciously crafted external stream, which is not possible in isolated environments \u2022 No remote attacker access: Without network ingress, attackers cannot trigger the vulnerability remotely. \u2022 Drastically reduced attack surface: The absence of any external media inputs effectively neutralizes the exploit path, significantly lowering the risk of both denial of service and code execution.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:F/RL:T/RC:C\">CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:F/RL:T/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-47360</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Videolan VLC prior to version 3.0.20 contains an Integer underflow that leads to an incorrect packet length.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-47360\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 Air-gapped environments only: Camera Connect is deployed in completely isolated environments lacking any network connectivity or internet access. \u2022 No exposure to MMS streams: The vulnerability depends on processing crafted MMS streams, which cannot originate from external or internal network sources when the system is air-gapped. \u2022 Elimination of remote attack surface: Without any method for an attacker to deliver malicious media inputs, the vulnerability cannot be triggered remotely. \u2022 Strong reduction in exploitation risk: The combined absence of external media ingestion and unavailable network paths effectively neutralizes the integer underflow exploit, significantly reducing the likelihood of both denial-of-service and memory corruption scenarios.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/191.html\">CWE-191 Integer Underflow (Wrap or Wraparound)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-47359</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Videolan VLC prior to version 3.0.20 contains an incorrect offset read that leads to a Heap-Based Buffer Overflow in function GetPacket() and results in a memory corruption.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-47359\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Given that Camera Connect is deployed exclusively in fully isolated, air-gapped environments with no internet access or external network connectivity, the following risk-reduction factors apply: \u2022 No exposure to crafted MMS streams: The exploit requires the receipt of specially crafted packets via the MMS protocol, which cannot occur without network connectivity. \u2022 Network attack vector eliminated: As the vulnerability\u2019s CVSS vector highlights a network-based attack (AV:N), the lack of any ingress network path nullifies the attack surface. \u2022 Low likelihood of exploitation: Without access to malicious media input, there is effectively no practical method for an attacker to trigger memory corruption, making the likelihood of denial of service or arbitrary code execution negligible.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-46814</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A binary hijacking vulnerability exists within the VideoLAN VLC media player before 3.0.19 on Windows. The uninstaller attempts to execute code with elevated privileges out of a standard user writable location. Standard users may use this to gain arbitrary code execution as SYSTEM.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-46814\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Given that the VLC-based component is installed exclusively within air-gapped environments under strict administrative control, the following factors substantially reduce risk: \u2022 Restricted user access: Only trusted, privileged users perform installations and modifications. Standard users have no write permissions to the uninstaller directory. \u2022 No internet or network access: The exploit requires local manipulation of VLC\u2019s uninstaller files; without external connectivity, remote coercion or manipulation is impossible. \u2022 Elimination of attacker vector: In air gapped deployments with administrative controls, un-privileged users cannot place malicious DLLs or executables in the uninstaller\u2019s search path. \u2022 Minimized privilege escalation risk: The combination of controlled write access, absence of network exposure, and trusted user roles effectively neutralizes the binary hijacking threat, rendering successful exploitation highly unlikely.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/427.html\">CWE-427 Uncontrolled Search Path Element</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-41325</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An integer overflow in the VNC module in VideoLAN VLC Media Player through 3.0.17.4 allows attackers, by tricking a user into opening a crafted playlist or connecting to a rogue VNC server, to crash VLC or execute code under some conditions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-41325\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Camera Connect is deployed exclusively in air-gapped environments with no internet connectivity or external network access, which significantly reduces the risk: \u2022 No exposure to malicious MKV files: The exploit requires a specially crafted Matroska file. In controlled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-26664</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability in EbmlTypeDispatcher::send in VideoLAN VLC media player 3.0.11 allows attackers to trigger a heap-based buffer overflow via a crafted .mkv file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-26664\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-19721</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An off-by-one error in the DecodeBlock function in codec/sdl_image.c in VideoLAN VLC media player before 3.0.9 allows remote attackers to cause a denial of service (memory corruption) via a crafted image file. NOTE: this may be related to the SDL_Image product.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-19721\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/193.html\">CWE-193 Off-by-one Error</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13962</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>lavc_CopyPicture in modules/codec/avcodec/video.c in VideoLAN VLC media player through 3.0.7 has a heap-based buffer over-read because it does not properly validate the width and height.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13962\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious MKV files: The exploit requires a specially crafted MKV file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13615</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>libebml before 1.3.6, as used in the MKV module in VideoLAN VLC Media Player binaries before 3.0.3, has a heap-based buffer over-read in EbmlElement::FindNextElement.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13615\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-13602</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Integer Underflow in MP4_EIA608_Convert() in modules/demux/mp4/mp4.c in VideoLAN VLC me-dia player through 3.0.7.1 allows remote attackers to cause a denial of service (heap-based buffer over-flow and crash) or possibly have unspecified other impact via a crafted .mp4 file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-13602\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/191.html\">CWE-191 Integer Underflow (Wrap or Wraparound)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-5460</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Double Free in VLC versions &lt;= 3.0.6 leads to a crash.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-5460\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/415.html\">CWE-415 Double Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-5459</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Integer underflow in VLC Media Player versions &lt; 3.0.7 leads to an out-of-band read.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-5459\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/191.html\">CWE-191 Integer Underflow (Wrap or Wraparound)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-5439</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Buffer Overflow in VLC Media Player &lt; 3.0.7 causes a crash which can possibly be further developed into a remote code execution exploit.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-5439\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>\u2022 No exposure to malicious ASF files: The exploit requires a specially crafted ASF file. In con-trolled environments without external media sources, such files cannot be introduced. \u2022 Remote attack vector eliminated: The vulnerability\u2019s CVSS vector indicates a network-based attack scenario, which is impossible without connectivity. \u2022 Strict operational controls: Media ingestion is limited to trusted sources under administrative supervision, further minimizing the likelihood of malicious file introduction. \u2022 Effective risk reduction: These combined factors render exploitation highly improbable, neutralizing the buffer overflow threat.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-11529</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>VideoLAN VLC media player 2.2.x is prone to a use after free vulnerability which an attacker can lever-age to execute arbitrary code via crafted MKV files. Failed exploit attempts will likely result in denial of service conditions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-11529\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The affected software is deployed exclusively in isolated environments with no internet connectivity and restricted external access. Exploitation of this vulnerability requires a user to open a specially crafted MKV file provided by an attacker. Since the system operates in a controlled network without exposure to untrusted sources, the likelihood of receiving and executing malicious media files is significantly reduced. Additionally, operational procedures can enforce the use of trusted media files only, further minimizing the risk.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-17670</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In VideoLAN VLC media player through 2.2.8, there is a type conversion vulnerability in mod-ules/demux/mp4/libmp4.c in the MP4 demux module leading to a invalid free, because the type of a box may be changed between a read operation and a free operation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-17670\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The affected VLC component is deployed exclusively in fully isolated, air gapped environments with no internet connectivity and tightly controlled external sources. Exploitation of CVE 2017 17670 re-quires a user to open a specifically crafted MP4 file containing a type conversion error in the demuxer. Since the system only processes trusted media files\u2014validated through internal procedures and se-cured media channels\u2014the probability of exposure to hostile MP4 content is minimal. Therefore, the risk of successful exploitation is significantly mitigated by the restricted deployment context.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-10699</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>avcodec 2.2.x, as used in VideoLAN VLC media player 2.2.7-x before 2017-06-29, allows out-of-bounds heap memory write due to calling memcpy() with a wrong size, leading to a denial of service (application crash) or possibly code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-10699\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>No network-based exposure: The vulnerability requires an external actor to supply malicious media content. With no Internet connectivity and presumably controlled file sources, the risk of loading un-trusted files is minimal.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-9301</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>plugins\\audio_filter\\libmpgatofixed32_plugin.dll in VideoLAN VLC media player 2.2.4 allows remote attackers to cause a denial of service (invalid read and application crash) or possibly have unspecified other impact via a crafted file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-9301\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>This vulnerability affects the libmpgatofixed32_plugin.dll module in VLC 2.2.4, which is responsible for decoding MPEG audio streams. The software in question does not process audio files or use any functionality related to audio decoding, meaning the vulnerable component is never invoked during normal operation. Additionally, the deployment environment is fully offline with no internet connectivity, and media ingestion is restricted to trusted internal sources. As a result, the attack surface for this vulnerability is effectively nonexistent, and the risk of exploitation is negligible under these conditions.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-9300</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>plugins\\codec\\libflac_plugin.dll in VideoLAN VLC media player 2.2.4 allows remote attackers to cause a denial of service (heap corruption and application crash) or possibly have unspecified other impact via a crafted FLAC file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-9300\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>This vulnerability affects VLC\u2019s FLAC audio processing component. Camera Connect does not handle or process audio files, meaning the vulnerable code path is never executed during normal operation. Combined with the fact that the deployment environment is fully isolated (air gapped) and does not allow external file transfers from untrusted sources, the likelihood of exploitation is effectively eliminated.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-8313</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Heap out-of-bound read in ParseJSS in VideoLAN VLC before 2.2.5 due to missing check of string termination allows attackers to read data beyond allocated memory and potentially crash the process via a crafted subtitles file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-8313\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Even though the affected VLC version (2.2.4) contains this vulnerability, the software is deployed in fully air-gapped environments with no external or internet-facing connectivity. As a result, the likeli-hood of exploiting this vulnerability is extremely low.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-8312</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Heap out-of-bound read in ParseJSS in VideoLAN VLC due to missing check of string length allows attackers to read heap uninitialized data via a crafted subtitles file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-8312\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Because the affected VLC version (2.2.4) suffers from a heap out of bound read in the ParseJSS function\u2014allowing an attacker to read uninitialized heap data via a crafted subtitles file\u2014the risk of external exploitation is significantly reduced in your environment. Since the software is installed in strictly isolated systems with no internet access, no external attacker can deliver malicious subtitle files re-motely. Consequently, the only remaining exposure is local: an insider would need to intentionally load a crafted subtitle file to trigger the issue\u2014a scenario considered highly unlikely under current governance and usage controls.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-8311</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Potential heap based buffer overflow in ParseJSS in VideoLAN VLC before 2.2.5 due to skipping NULL terminator in an input string allows attackers to execute arbitrary code via a crafted subtitles file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-8311\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Since the application is deployed exclusively in isolated, air-gapped environments with no external network connectivity, the attack vector\u2014specifically, the ability for an attacker to deliver a crafted subtitle file\u2014is significantly constrained.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-8310</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Heap out-of-bound read in CreateHtmlSubtitle in VideoLAN VLC 2.2.x due to missing check of string termination allows attackers to read data beyond allocated memory and potentially crash the process (causing a denial of service) via a crafted subtitles file.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-8310\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Camera Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Camera Connect &lt;=1.5.0.14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Because your team\u2019s VLC based software is deployed only in isolated environments without internet access, the risk of malicious delivery of crafted subtitle files is greatly diminished. This significantly reduces exploitation likelihood.</p>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: ABB Ability Camera Connect 1.5.0.15 The 3rd party component has already been updated. The easiest path to mitigate the problem is an update of just VLC Media Player by the customer. ABB recommends that customers apply the update at earliest convenience. It is also possible to update to the latest Version of Camera Connect.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently Asked Questions</h2>\n<p>What causes the vulnerability? The vulnerability is caused by unchecked input data in the VLC media player in Camera Connect What is ? VLC media player What might an attacker use the vulnerability to do? An attacker who successfully exploited this vulnerability could cause the affected system node to stop or become inaccessible and allow the attacker to insert and run arbitrary code . How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by creating a specially crafted file, copying the file to affected system nodes and then manually open the file via VLC Mediaplayer. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? No, to exploit this vulnerability an attacker would need to have physical access to an affected system node. Can functional safety be affected by an exploit of this vulnerability? While these vulnerabilities primarily impact confidentiality, integrity, and availability, they do not directly affect functional safety in the traditional sense. However, a compromised system (due to arbitrary code execution or a critical service crash) may compromise safety-related processes dependent on VLC, potentially disrupting business operations or compliance. What does the update do? The update removes the vulnerability by providing a newer version of the VLC media player When this security advisory was issued, had this vulnerability been publicly disclosed? This vulnerability has been publicly disclosed for the 3rd party component, but not for the ABB product using this component When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 4HZM000603 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-11-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-11-27</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2025-11-28</td>\n<td>2</td>\n<td>Correction in References</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT 4HZM000603 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-146-01",
        "title": "Eppendorf BioFlo 320",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-146-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-146-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to gain full access to functionality and data with the bioreactor.</strong></p>\n<p>The following versions of Eppendorf BioFlo 320 are affected:</p>\n<ul>\n<li>BioFlo 320 Bioreactor vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Eppendorf</td>\n<td>Eppendorf BioFlo 320</td>\n<td>Use of Hard-coded Password</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-7251</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is vulnerable to due to VNC server using a hard-coded password. If a remote attacker knows the network address of any BioFlo 320 model with remote access enabled, they can gain full control of the user interface by using this password. Once connected, the attacker would have full access to all control panel features for the BioFlo 320. VNC traffic is not encrypted.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-7251\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Eppendorf BioFlo 320</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Eppendorf</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Eppendorf BioFlo 320 Bioreactor: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Eppendorf has released a software update that permanently removes VNC access from the controller. Users should download and apply this update from: https://www.eppendorf.com/software-downloads.<br><a href=\"https://www.eppendorf.com/software-downloads\">https://www.eppendorf.com/software-downloads</a></p>\n<p><strong>Mitigation</strong><br>All affected BioFlo 320 systems always shipped with Virtual Network Computing (VNC) disabled by default, and VNC can only be enabled locally at the tower. Eppendorf has removed VNC configuration information from all current documentation, so it no longer appears in BioFlo 320 Operating Manuals.</p>\n<p><strong>Mitigation</strong><br>Eppendorf recommends user do the following:<br>Verify that VNC is disabled on the controller<br>Enable security so that only Admin and Supervisor roles can change VNC settings<br>Install Version 5.0 Software as soon as possible</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/259.html\">CWE-259 Use of Hard-coded Password</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>BIO-ISAC reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-26</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-26</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/26/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added&nbsp;one&nbsp;new vulnerability&nbsp;to its&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.&nbsp;</p>\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48172\" target=\"_blank\">CVE-2026-48172</a>&nbsp;LiteSpeed&nbsp;cPanel Plugin Privilege Escalation Vulnerability</li>\n</ul>\n<p>This&nbsp;type of vulnerability is a&nbsp;frequent attack vector for malicious cyber actors and poses&nbsp;significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a>&nbsp;established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the&nbsp;<a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a>&nbsp;for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing&nbsp;timely&nbsp;remediation of&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>&nbsp;as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-02",
        "title": "ABB AC500 V2",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC</strong></p>\n<p>The following versions of ABB AC500 V2 are affected:</p>\n<ul>\n<li>AC500 V2 &lt;=2.5.2, 2.5.3</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.8</td>\n<td>ABB</td>\n<td>ABB AC500 V2</td>\n<td>Buffer Over-read</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7745</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Sending unsupported function codes to the AC500 V2 Modbus server might result in invalid responses. Fragments of previous responses might be added to the end of the response.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7745\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB AC500 V2</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB AC500 V2 &lt;=2.5.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/126.html\">CWE-126 Buffer Over-read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Reid Wightman of Dragos. Inc reported these vulnerabilities to Schneider Electric.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Regarding this vulnerability it is recommended to \u2022 Do not use the Modbus server for sending any sensitive data, as fragments might be accessible even after the initial sending of the response \u2022 Only use supported Modbus function codes, as invalid responses to unsupported function codes might have negative effects on the requesting Modbus client. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 3ADR011432 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-07-23</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-07-23</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-22</td>\n<td>2</td>\n<td>Minor correction to the affected product version in the product tree.</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT 3ADR011432 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-01",
        "title": "ABB Terra AC",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior.</strong></p>\n<p>The following versions of ABB Terra AC are affected:</p>\n<ul>\n<li>Terra AC wallbox (UL40/80A) &lt;=1.8.32, 1.8.33</li>\n<li>Terra AC wallbox (UL32A) &lt;=1.8.2, 1.8.34</li>\n<li>Terra AC wallbox (MID/ CE) &lt;=1.8.32, 1.8.34</li>\n<li>Terra AC wallbox (JP) &lt;=1.8.2, 1.8.34</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.8</td>\n<td>ABB</td>\n<td>ABB Terra AC</td>\n<td>Heap-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-5517</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is potential risk to pollute the memory when a specially crafted OCPP message may be sent to a target vulnerable charger by exploiting unencrypted communication to the Charging Station Management System (CSMS) or fully remotely from its CSMS server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-5517\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Terra AC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Terra AC wallbox (UL40/80A) &lt;=1.8.32, ABB Terra AC wallbox (UL32A) &lt;=1.8.2, ABB Terra AC wallbox (MID/ CE) Terra AC MID &lt;=1.8.32, ABB Terra AC wallbox (JP) &lt;=1.8.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the product versions listed as fixed in the advisory. Terra AC wallbox (UL40/80A) 1.8.33 Terra AC wallbox (UL32A) 1.8.34 Terra AC MID 1.8.34 Terra AC Juno CE 1.8.34 Terra AC PTB 1.8.33 Terra AC wallbox (JP) 1.8.34 Additionally, we strongly recommend not use unsafe mode(http) to connect your charger to your backend even though OCPP is allowed to do in this way, which absolutely could be attacked by malicious man or organization as a common knowledge. ABB recommends that customers apply the update at earliest convenience.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Itai Shmueli of Saiflow reported this vulnerability to Schneider Electric.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>To attack with this kind of message, hackers must hijack CSMS (OCPP backends) first and then can send messages, OR the way to OCPP backend is unsafe itself (http) which can cause any kind of attack behavior and known as a common knowledge. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<hr>\n<h2>Workarounds</h2>\n<p>Make sure OCPP backend that chargers are connected is strictly secured to avoid any kind of at-tack especially the communication relevant components. Use https(TLS) as basic communication foundation between charger and OCPP backend instead of http.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerability? The vulnerability is caused by firmware which it didn\u2019t limit the length of OCPP field in certain case. What is Terra AC wallbox? Terra AC wallbox is a Level 2 Electric Vehicle charger. What might an attacker use the vulnerability to do? An attacker who successfully exploited this vulnerability could cause the affected system node to take control of the charger to response wrong messages, Denial-of-Service, compromised internal state, and possibly remote code execution. How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by sending a specially crafted OCPP message to chargers via OCPP backend(CSMS), which could be done remotely. This would require that the attacker has access to the system network and hijack the API of sending message OR hijack the network data directly if the charger is connected with unsafe http mode. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Can functional safety be affected by an exploit of this vulnerability? The charger potentially is running with unpredictable mode, including Denial-of-Service, compromised internal state, and possibly remote code execution. What does the update do? The update removes the vulnerability by modifying the validation rules of receiving data from OCPP backend. When this security advisory was issued, had this vulnerability been publicly disclosed? No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A8948 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-10-20</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-10-20</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2025-10-21</td>\n<td>2</td>\n<td>Final version</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT 9AKK108471A8948 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-03",
        "title": "ABB Ability Zenon Remote Transport Vulnerability (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-146-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-146-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this vulnerability is not feasible unless the attacker has already gained access to the network where the affected ABB Ability Zenon system is deployed. At the time of writing, there is no evidence that this vulnerability is being actively exploited in the wild.</strong></p>\n<p>The following versions of ABB Ability Zenon Remote Transport Vulnerability are affected:</p>\n<ul>\n<li>Ability Zenon &gt;=7.50|&lt;=14</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>ABB</td>\n<td>ABB Ability Zenon Remote Transport Vulnerability</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-8754</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the default configuration of the ABB Zenon software platform, the zensyssrv.exe service is set to start automatically. To utilize the Remote Transport Service, users are required to configure a password beforehand. However, a security vulnerability has been identified that enables unauthorized attackers to bypass authentication mechanisms and remotely initiate a system reboot without proper authorization</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-8754\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Zenon Remote Transport Vulnerability</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Zenon &gt;=7.50|&lt;=14</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Workaround</strong><br>\u2022 Restrict network access to systems with the ABB Zenon Software Platform installed. - Ensure that access to a system is restricted by implementing access controls to minimize the risk of unauthorized access. \u2022 Assess the necessity of the ABB Zenon Remote Transport functionality. - Ensure that if the Remote Transport functionality is not used, the zensyssrv.exe (ABB Zenon System Service) is stopped or terminated. The zensyssrv.exe can also be stopped or terminated after authorized use to prevent this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Work around</h2>\n<p>\u2022 Restrict network access to systems with the ABB zenon Software Platform installed. - Ensure that access to a system is restricted by implementing access controls to minimize the risk of unauthorized access. \u2022 Assess the necessity of the ABB Zenon Remote Transport functionality. - Ensure that if the Remote Transport functionality is not used, the zensyssrv.exe (ABB Zenon System Service) is stopped or terminated. The zensyssrv.exe can also be stopped or terminated after authorized use to prevent this vulnerability.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 2NGA002743 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-08-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-08-12</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-22</td>\n<td>2</td>\n<td>Minor correction to the affected product version in the product tree.</td>\n</tr>\n<tr>\n<td>2026-05-26</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT 2NGA002743 advisory</td>\n</tr>\n<tr>\n<td>2026-05-28</td>\n<td>4</td>\n<td>CISA Republication update based on ABB PSIRT 2NGA002743 advisory. Removed \"Trademark\" abbreviation from the Ability product name in the title and throughout the advisory.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 26 May 26 12:00:00 +0000",
        "last_updated": "Tue, 26 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/22/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/22/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9082\" target=\"_blank\">CVE-2026-9082</a> Drupal Core SQL Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 22 May 26 12:00:00 +0000",
        "last_updated": "Fri, 22 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-05",
        "title": "ABB Terra AC Wallbox",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior.</strong></p>\n<p>The following versions of ABB Terra AC Wallbox are affected:</p>\n<ul>\n<li>Terra AC wallbox (JP) &lt;=1.8.33, 1.8.36 (CVE-2025-10504, CVE-2025-12142, CVE-2025-12143)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>ABB</td>\n<td>ABB Terra AC Wallbox</td>\n<td>Heap-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Stack-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-10504</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is potential risk to pollute the memory when developing apps which has used to communicate with charger according to self-defined protocol if developers don\u2019t strictly follow the field length which has not been validated in firmware.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-10504\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Terra AC Wallbox</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Terra AC wallbox (JP) &lt;=1.8.33</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience.</p>\n<p><strong>Mitigation</strong><br>To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-12142</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is potential risk of polluting the BSS memory when developing apps which are used to communicate with charger via Bluetooth according to self-defined protocol if developers configure an unexpected length of bin files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-12142\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Terra AC Wallbox</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Terra AC wallbox (JP) &lt;=1.8.33</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience.</p>\n<p><strong>Mitigation</strong><br>To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-12143</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is potential risk of polluting the stack memory when developing a customized OCPP key of \u201cRan-domDelay\u201c in backend and configuring an unexpected number in the field.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-12143\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Terra AC Wallbox</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Terra AC wallbox (JP) &lt;=1.8.33</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience.</p>\n<p><strong>Mitigation</strong><br>To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A8107 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-09-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-09-16</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2025-09-28</td>\n<td>2</td>\n<td>DocumentID update</td>\n</tr>\n<tr>\n<td>2025-09-28</td>\n<td>3</td>\n<td>Minor corrections</td>\n</tr>\n<tr>\n<td>2025-10-09</td>\n<td>4</td>\n<td>CVSS update</td>\n</tr>\n<tr>\n<td>2025-10-27</td>\n<td>5</td>\n<td>CVE update</td>\n</tr>\n<tr>\n<td>2025-11-28</td>\n<td>6</td>\n<td>CVE update</td>\n</tr>\n<tr>\n<td>2025-11-28</td>\n<td>7</td>\n<td>Fixed Version update</td>\n</tr>\n<tr>\n<td>2026-05-21</td>\n<td>8</td>\n<td>Initial CISA Republication of ABB PSIRT 9AKK108471A8107 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-02",
        "title": "ABB B&R PCs",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. A network attacker could exploit the vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information.</strong></p>\n<p>The following versions of ABB B&amp;R PCs are affected:</p>\n<ul>\n<li>APC4100 &lt;1.09, 1.09 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>APC910 &lt;=1.25 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>C80 &lt;1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>MPC3100 &lt;1.24, 1.24 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>PPC1200 &lt;1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>PPC900 &lt;2.16, 2.16 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>APC2200 &lt;1.35, 1.35 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>PPC2200 &lt;1.35, 1.35 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>APC3100 &lt;1.45, 1.45 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n<li>PPC3100 &lt;1.45, 1.45 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>ABB</td>\n<td>ABB B&amp;R PCs</td>\n<td>Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer, Loop with Unreachable Exit Condition ('Infinite Loop'), Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45229</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing the IA_NA or IA_TA option in a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45229\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45230</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to a buffer overflow vulnerability via a long server ID option in DHCPv6 client. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45230\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45231</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing Neighbor Discovery Redirect message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45231\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45232</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to an infinite loop vulnerability when parsing unknown options in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45232\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/835.html\">CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45233</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to an infinite loop vulnerability when parsing a PadN option in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45233\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/835.html\">CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45234</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to a buffer overflow vulnerability when processing DNS Servers option from a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45234\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45235</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to a buffer overflow vulnerability when handling Server ID option from a DHCPv6 proxy Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45235\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45236</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to a predictable TCP Initial Sequence Number. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45236\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/338.html\">CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-45237</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>EDK2's Network Package is susceptible to a predictable TCP Initial Sequence Number. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-45237\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R PCs</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB APC4100 &lt;1.09, ABB APC910 &lt;=1.25, ABB C80 &lt;1.14, ABB MPC3100 &lt;1.24, ABB PPC1200 &lt;1.14, ABB PPC900 &lt;2.16, ABB APC2200 &lt;1.35, ABB PPC2200 &lt;1.35, ABB APC3100 &lt;1.45, ABB PPC3100 &lt;1.45</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/338.html\">CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently Asked Questions</h2>\n<p>What is the scope of the vulnerabilities? - A network attacker who successfully exploited these vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. In worst case, these vulnerabilities can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability. What causes the vulnerabilities? - The vulnerabilities are caused by usage of vulnerable UEFI firmware in some B&amp;R xPCs. What is a B&amp;R xPC? - A B&amp;R xPC is an industrial PC (IPC) designed for use in industrial environments and is built to handle more demanding conditions than a standard PC. They often feature robust construction, resistance to dust and moisture, extended temperature ranges, and other specifications suited for industrial applications. What might an attacker use the vulnerabilities to do? - A network attacker who successfully exploited the vulnerabilities could execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. How could an attacker exploit the vulnerabilities? - An attacker could try to exploit the vulnerabilities by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerabilities be exploited remotely? - Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. What does the update do? - The update removes the vulnerabilities in the TCP/IP stack used by the UEFI firmware. When this security advisory was issued, had these vulnerabilities been publicly disclosed? - Yes, these vulnerabilities have been publicly disclosed. When this security advisory was issued, had B&amp;R received any reports that this vulnerability was being exploited on B&amp;R products? - No, B&amp;R had not received any information indicating that this vulnerability had been exploited on B&amp;R products when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA24P003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-01-29</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-01-29</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-21</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT SA24P003 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/05/21/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/05/21/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-34291\" target=\"_blank\">CVE-2025-34291</a> Langflow Origin Validation Error Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34926\" target=\"_blank\">CVE-2026-34926</a> Trend Micro Apex One (On-Premise) Directory Traversal Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities</a> established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the <a href=\"https://www.cisa.gov/sites/default/files/publications/Reducing_the_Significant_Risk_of_Known_Exploited_Vulnerabilities_211103.pdf\">BOD 22-01 Fact Sheet</a> for more information.</p>\n<p>Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a> as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-01",
        "title": "Hitachi Energy GMS600",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Hitachi Energy is aware of the vulnerability, CVE-2022-4304 in the OSS component OpenSSL, that affects the GMS600 versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. For immediate mitigation /workaround information, please refer to the General Mitigation Factors/Workarounds</strong></p>\n<p>The following versions of Hitachi Energy GMS600 are affected:</p>\n<ul>\n<li>GMS600 vers:GMS600/&gt;=1.3.0|&lt;=1.3.1 (CVE-2022-4304)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.9</td>\n<td>Hitachi Energy</td>\n<td>Hitachi Energy GMS600</td>\n<td>Observable Discrepancy</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-4304</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A timing-based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-4304\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy GMS600</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>GMS600 versions 1.3.0 and 1.3.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Upgrade to version 1.3.2</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/203.html\">CWE-203 Observable Discrepancy</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hitachi Energy Internal Team reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Support</h2>\n<p>For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.</p>\n<hr>\n<h2>General Mitigation Factors</h2>\n<p>Recommended security practices and firewall configurations such as enforcing ingress IP allowlisting and applying traffic rate limiting in accordance with the operational security policy can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.</p>\n<hr>\n<h2>SSVC</h2>\n<p>SSVCv2/E:N/A:Y/2026-04-22T13:37:14Z/</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000159 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2023-06-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2023-06-27</td>\n<td>1</td>\n<td>Initial public release.</td>\n</tr>\n<tr>\n<td>2026-04-28</td>\n<td>2</td>\n<td>Updated fixed version.</td>\n</tr>\n<tr>\n<td>2026-05-21</td>\n<td>3</td>\n<td>Initial CISA Republication of Hitachi Energy PSIRT 8DBD000159 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-03",
        "title": "ABB B&R Automation Studio",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&amp;R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.</strong></p>\n<p>The following versions of ABB B&amp;R Automation Studio are affected:</p>\n<ul>\n<li>B&amp;R Automation Studio &lt;6.5, 6.5 (CVE-2025-6965, CVE-2025-3277, CVE-2023-7104, CVE-2022-35737, CVE-2020-15358, CVE-2020-13632, CVE-2020-13631, CVE-2020-13630, CVE-2020-13435, CVE-2020-13434, CVE-2020-11656, CVE-2020-11655, CVE-2019-19646, CVE-2019-19645, CVE-2019-8457, CVE-2018-20506, CVE-2018-20505, CVE-2018-20346, CVE-2018-8740, CVE-2017-10989, CVE-2016-6153, CVE-2015-6607, CVE-2015-5895, CVE-2015-3717, CVE-2015-3416)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>ABB</td>\n<td>ABB B&amp;R Automation Studio</td>\n<td>Numeric Truncation Error, Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, NULL Pointer Dereference, Incorrect User Management, Use After Free, Integer Overflow or Wraparound, Improper Check for Unusual or Exceptional Conditions, Uncontrolled Recursion, Out-of-bounds Read, Improper Input Validation, Exposure of Sensitive Information to an Unauthorized Actor, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-6965</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-6965\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/197.html\">CWE-197 Numeric Truncation Error</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-3277</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An integer overflow vulnerability exists in SQLite's concat_ws() function that can lead to a massive heap buffer overflow. When triggered, the integer overflow results in a truncated size value being used for buffer allocation, while the original untruncated size is used for writing the resulting string, causing a heap buffer overflow of approximately 4GB.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-3277\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2023-7104</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability was found in SQLite SQLite3 up to 3.43.0 and classified as critical. This issue affects the function sessionReadRecord of the file ext/session/sqlite3session.c of the component make alltest Handler. The manipulation leads to heap-based buffer overflow.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-7104\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2022-35737</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite 1.0.12 through 3.39.x before 3.39.2 sometimes allows an array-bounds overflow if billions of bytes are used in a string argument to a C API.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-35737\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-15358</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In SQLite before 3.32.3, select.c mishandles query-flattener optimization, leading to a multiSelectOrderBy heap overflow because of misuse of transitive properties for constant propagation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-15358\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13632</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13632\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13631</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite before 3.32.0 allows a virtual table to be renamed to the name of one of its shadow tables, related to alter.c and build.c.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13631\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/286.html\">CWE-286 Incorrect User Management</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13630</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>ext/fts3/fts3.c in SQLite before 3.32.0 has a use-after-free in fts3EvalNextRow, related to the snippet feature.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13630\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13435</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite through 3.32.0 has a segmentation fault in sqlite3ExprCodeTarget in expr.c.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13435\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13434</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite through 3.32.0 has an integer overflow in sqlite3_str_vappendf in printf.c.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13434\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-11656</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In SQLite through 3.31.1, the ALTER TABLE implementation has a use-after-free, as demonstrated by an ORDER BY clause that belongs to a compound SELECT statement.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-11656\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/416.html\">CWE-416 Use After Free</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-11655</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite through 3.31.1 allows attackers to cause a denial of service (segmentation fault) via a malformed window-function query because the AggInfo object's initialization is mishandled.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-11655\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/754.html\">CWE-754 Improper Check for Unusual or Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-19646</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-19646\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/754.html\">CWE-754 Improper Check for Unusual or Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-19645</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>alter.c in SQLite through 3.30.1 allows attackers to trigger infinite recursion via certain types of self-referential views in conjunction with ALTER TABLE statements.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-19645\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/674.html\">CWE-674 Uncontrolled Recursion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-8457</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite3 from 3.6.0 to and including 3.27.2 is vulnerable to heap out-of-bound read in the rtreenode() function when handling invalid rtree tables.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-8457\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-20506</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite before 3.25.3, when the FTS3 extension is enabled, encounters an integer overflow (and resultant buffer overflow) for FTS3 queries in a \"merge\" operation that occurs after crafted changes to FTS3 shadow tables, allow-ing remote attackers to execute arbitrary code by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases). This is a different vulnerability than CVE-2018-20346.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-20506\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-20505</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite 3.25.2, when queries are run on a table with a malformed PRIMARY KEY, allows remote attackers to cause a denial of service (application crash) by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-20505\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-20346</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite before 3.25.3, when the FTS3 extension is enabled, encounters an integer overflow (and resultant buffer overflow) for FTS3 queries that occur after crafted changes to FTS3 shadow tables, allowing remote attackers to execute arbitrary code by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases), aka Magellan.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-20346\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-8740</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In SQLite through 3.22.0, databases whose schema is corrupted using a CREATE TABLE AS statement could cause a NULL pointer dereference, related to build.c and prepare.c.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-8740\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2017-10989</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The getNodeSize function in ext/rtree/rtree.c in SQLite through 3.19.3, as used in GDAL and other products, mis-handles undersized RTree blobs in a crafted database, leading to a heap-based buffer over-read or possibly un-specified other impact.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2017-10989\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2016-6153</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2016-6153\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C\">CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-6607</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>SQLite before 3.8.9, as used in Android before 5.1.1 LMY48T, allows attackers to gain privileges via a crafted application, aka internal bug 20099586.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-6607\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/286.html\">CWE-286 Incorrect User Management</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>3.7</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-5895</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple unspecified vulnerabilities in SQLite before 3.8.10.2, as used in Apple iOS before 9, have unknown im-pact and attack vectors.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-5895\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/200.html\">CWE-200 Exposure of Sensitive Information to an Unauthorized Actor</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-3717</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple buffer overflows in the printf functionality in SQLite, as used in Apple iOS before 8.4 and OS X before 10.10.4, allow remote attackers to execute arbitrary code or cause a denial of service (application crash) via un-specified vectors.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-3717\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2015-3416</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The sqlite3VXPrintf function in printf.c in SQLite before 3.8.9 does not properly handle precision and width values during floating-point conversions, which allows context-dependent attackers to cause a denial of service (integer overflow and stack-based buffer overflow) or possibly have unspecified other impact via large integers in a crafted printf function call in a SELECT statement.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-3416\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Studio</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB B&amp;R Automation Studio &lt;6.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: B&amp;R Automation Studio 6.5 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for advice on how to keep your system secure.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.0</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\">CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA25P007 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-02-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-02-18</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-05-21</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT SA25P007 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-04",
        "title": "ABB B&R Automation Runtime",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>An update is available that resolves a vulnerability identified by B&amp;Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could take over a remote session or execute code in the context of the user\u2019s browser session.</strong></p>\n<p>The following versions of ABB B&amp;R Automation Runtime are affected:</p>\n<ul>\n<li>Automation Runtime &lt;6.4, 6.4 (CVE-2025-3449, CVE-2025-3448, CVE-2025-11498)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>B&amp;R</td>\n<td>ABB B&amp;R Automation Runtime</td>\n<td>Generation of Predictable Numbers or Identifiers, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Formula Elements in a CSV File</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-3449</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Generation of Predictable Numbers or Identifiers vulnerability in the SDM component of B&amp;R Automation Runtime versions before 6.4 may allow an unauthenticated network-based attacker to take over already established sessions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-3449\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automation Runtime &lt;6.4</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&amp;R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/340.html\">CWE-340 Generation of Predictable Numbers or Identifiers</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.2</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N/E:F/RL:O/RC:C\">CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N/E:F/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-3448</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Reflected cross-site scripting (XSS) vulnerabilities exist in System Diagnostics Manager (SDM) of B&amp;R Automation Runtime versions before 6.4 that enables a remote attacker to execute arbitrary JavaScript code in the context of the attacked user\u2019s browser session</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-3448\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automation Runtime &lt;6.4</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&amp;R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:F/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:F/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11498</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An Improper Neutralization of Formula Elements in a CSV File vulnerability exists in System Diagnostics Manager (SDM) of B&amp;R Automation Runtime versions before 6.4 enabling a remote attacker to inject formula data into a generated CSV file. The exploitation of this vulnerability requires the attack-er to create a malicious link. The user would need to click on this link, after which the resulting CSV file additionally needs to be manually opened.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11498\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB B&amp;R Automation Runtime</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Automation Runtime &lt;6.4</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&amp;R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1236.html\">CWE-1236 Improper Neutralization of Formula Elements in a CSV File</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/RL:O/RC:C\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/RL:O/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Mitigating factors</h2>\n<p>Do not enable the System Diagnostics Manager when it is not required. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<hr>\n<h2>Workarounds</h2>\n<p>Do not use Hyperlinks provided by untrusted 3rd party to access the SDM. Hyperlinks may be provided via: \u2022 Emails from unknown users \u2022 Social media channels \u2022 Messaging services \u2022 Webpages with comment functionality \u2022 QR Codes The use of external Web Application Firewalls (WAF) can mitigate attacks using reflected cross-site scripting.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerabilities? The vulnerabilities are caused by insufficient input sanitization and generation of predictable numbers. What is System Diagnostics Manager (SDM)? System Diagnostics Manager (SDM) is a webpage available over the Automation Runtime Webserver, showing key diagnostic information of the running controller. What is Automation Runtime (AR)? B&amp;R Automation Runtime is a middleware system enabling customers to run applications on B&amp;R target systems. What might an attacker use the vulnerabilities to do? An attacker who successfully exploited these vulnerabilities could cause to run arbitrary code in the context of the user\u2019s browser session or take over the user\u2019s session. Since the SDM currently does not process any session-specific data and also does not implement authentication mechanisms at the session level, B&amp;R is not aware of any advantages an attacker could gain by taking over the session ID How could an attacker exploit the vulnerabilities? To exploit the XSS vulnerability CVE-2025-3448, an attacker could try to create a hyperlink including malicious script code. This hyperlink must be opened by the user to launch the attack. To exploit vulnerability CVE-2025-3449, an attacker would need to guess a user's session ID. Could the vulnerabilities be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had this vulnerability been publicly disclosed? No, B&amp;R discovered the vulnerabilities through its own security analysis. When this security advisory was issued, had B&amp;R received any reports that this vulnerability was being exploited? No, B&amp;R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA25P003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-10-07</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-10-07</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2025-10-14</td>\n<td>2</td>\n<td>Added information about CVE-2025-11498</td>\n</tr>\n<tr>\n<td>2026-05-21</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT SA25P003 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 21 May 26 12:00:00 +0000",
        "last_updated": "Thu, 21 May 26 12:00:00 +0000"
    }
]