· CISA Cybersecurity Advisory

ABB AC500 V2

View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical…
Read full source summary
View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7745 Sending unsupported function codes to the AC500 V2 Modbus server might result in invalid responses. Fragments of previous responses might be added to the end of the response. View CVE Details Affected Products ABB AC500 V2 Vendor: ABB Product Version: ABB AC500 V2 <=2.5.2 Product Status: fixed, known_affected Remediations Vendor fix The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N Acknowledgments Reid Wightman of Dragos. Inc reported these vulnerabilities to Schneider Electric. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Regarding this vulnerability it is recommended to • Do not use the Modbus server for sending any sensitive data, as fragments might be accessible even after the initial sending of the response • Only use supported Modbus function codes, as invalid responses to unsupported function codes might have negative effects on the requesting Modbus client. Refer to section “General security recommendations” for further advise on how to keep your system secure. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 3ADR011432 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-07-23 Date Revision Summary 2025-07-23 1 Initial version. 2026-05-22 2 Minor correction to the affected product version in the product tree. 2026-05-26 3 Initial CISA Republication of ABB PSIRT 3ADR011432 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Terra AC

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox (UL40/80A) <=1.8.32, 1.8.33 Terra AC wallbox (UL32A) <=1.8.2, 1.8.34 Terra AC wallbox (MID/ CE) <=1.8.32, 1.8.34 Terra AC wallbox (JP) <=1.8.2, 1.8.34 CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Terra AC Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-5517 There is potential risk to pollute the memory when a specially crafted OCPP message may be sent to a target vulnerable charger by exploiting unencrypted communication to the Charging Station Management System (CSMS) or fully remotely from its CSMS server. View CVE Details Affected Products ABB Terra AC Vendor: ABB Product Version: ABB Terra AC wallbox (UL40/80A) <=1.8.32, ABB Terra AC wallbox (UL32A) <=1.8.2, ABB Terra AC wallbox (MID/ CE) Terra AC MID <=1.8.32, ABB Terra AC wallbox (JP) <=1.8.2 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the product versions listed as fixed in the advisory. Terra AC wallbox (UL40/80A) 1.8.33 Terra AC wallbox (UL32A) 1.8.34 Terra AC MID 1.8.34 Terra AC Juno CE 1.8.34 Terra AC PTB 1.8.33 Terra AC wallbox (JP) 1.8.34 Additionally, we strongly recommend not use unsafe mode(http) to connect your charger to your backend even though OCPP is allowed to do in this way, which absolutely could be attacked by malicious man or organization as a common knowledge. ABB recommends that customers apply the update at earliest convenience. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C Acknowledgments Itai Shmueli of Saiflow reported this vulnerability to Schneider Electric. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors To attack with this kind of message, hackers must hijack CSMS (OCPP backends) first and then can send messages, OR the way to OCPP backend is unsafe itself (http) which can cause any kind of attack behavior and known as a common knowledge. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workarounds Make sure OCPP backend that chargers are connected is strictly secured to avoid any kind of at-tack especially the communication relevant components. Use https(TLS) as basic communication foundation between charger and OCPP backend instead of http. Frequently asked questions What causes the vulnerability? The vulnerability is caused by firmware which it didn’t limit the length of OCPP field in certain case. What is Terra AC wallbox? Terra AC wallbox is a Level 2 Electric Vehicle charger. What might an attacker use the vulnerability to do? An attacker who successfully exploited this vulnerability could cause the affected system node to take control of the charger to response wrong messages, Denial-of-Service, compromised internal state, and possibly remote code execution. How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by sending a specially crafted OCPP message to chargers via OCPP backend(CSMS), which could be done remotely. This would require that the attacker has access to the system network and hijack the API of sending message OR hijack the network data directly if the charger is connected with unsafe http mode. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Can functional safety be affected by an exploit of this vulnerability? The charger potentially is running with unpredictable mode, including Denial-of-Service, compromised internal state, and possibly remote code execution. What does the update do? The update removes the vulnerability by modifying the validation rules of receiving data from OCPP backend. When this security advisory was issued, had this vulnerability been publicly disclosed? No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A8948 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-10-20 Date Revision Summary 2025-10-20 1 Initial version. 2025-10-21 2 Final version 2026-05-26 3 Initial CISA Republication of ABB PSIRT 9AKK108471A8948 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Ability Zenon Remote Transport Vulnerability (Update A)

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this vulnerability is not feasible unless the attacker has already gained access to the network where the affected ABB Ability Zenon system is deployed. At the time of writing, there is no evidence that this vulnerability is being actively exploited in the wild. The following versions of ABB Ability Zenon Remote Transport Vulnerability are affected: Ability Zenon >=7.50|<=14 CVSS Vendor Equipment Vulnerabilities v3 7.5 ABB ABB Ability Zenon Remote Transport Vulnerability Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-8754 In the default configuration of the ABB Zenon software platform, the zensyssrv.exe service is set to start automatically. To utilize the Remote Transport Service, users are required to configure a password beforehand. However, a security vulnerability has been identified that enables unauthorized attackers to bypass authentication mechanisms and remotely initiate a system reboot without proper authorization View CVE Details Affected Products ABB Ability Zenon Remote Transport Vulnerability Vendor: ABB Product Version: ABB Ability Zenon >=7.50|<=14 Product Status: known_affected Remediations Workaround • Restrict network access to systems with the ABB Zenon Software Platform installed. - Ensure that access to a system is restricted by implementing access controls to minimize the risk of unauthorized access. • Assess the necessity of the ABB Zenon Remote Transport functionality. - Ensure that if the Remote Transport functionality is not used, the zensyssrv.exe (ABB Zenon System Service) is stopped or terminated. The zensyssrv.exe can also be stopped or terminated after authorized use to prevent this vulnerability. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Work around • Restrict network access to systems with the ABB zenon Software Platform installed. - Ensure that access to a system is restricted by implementing access controls to minimize the risk of unauthorized access. • Assess the necessity of the ABB Zenon Remote Transport functionality. - Ensure that if the Remote Transport functionality is not used, the zensyssrv.exe (ABB Zenon System Service) is stopped or terminated. The zensyssrv.exe can also be stopped or terminated after authorized use to prevent this vulnerability. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 2NGA002743 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-08-12 Date Revision Summary 2025-08-12 1 Initial version. 2026-05-22 2 Minor correction to the affected product version in the product tree. 2026-05-26 3 Initial CISA Republication of ABB PSIRT 2NGA002743 advisory 2026-05-28 4 CISA Republication update based on ABB PSIRT 2NGA002743 advisory. Removed "Trademark" abbreviation from the Ability product name in the title and throughout the advisory. Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Eppendorf BioFlo 320

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full access to functionality and data with the bioreactor. The following versions of Eppendorf BioFlo 320 are affected: BioFlo 320 Bioreactor vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Eppendorf Eppendorf BioFlo 320 Use of Hard-coded Password Background Critical Infrastructure Sectors: Healthcare and Public…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full access to functionality and data with the bioreactor. The following versions of Eppendorf BioFlo 320 are affected: BioFlo 320 Bioreactor vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Eppendorf Eppendorf BioFlo 320 Use of Hard-coded Password Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-7251 The affected product is vulnerable to due to VNC server using a hard-coded password. If a remote attacker knows the network address of any BioFlo 320 model with remote access enabled, they can gain full control of the user interface by using this password. Once connected, the attacker would have full access to all control panel features for the BioFlo 320. VNC traffic is not encrypted. View CVE Details Affected Products Eppendorf BioFlo 320 Vendor: Eppendorf Product Version: Eppendorf BioFlo 320 Bioreactor: vers:all/* Product Status: known_affected Remediations Mitigation Eppendorf has released a software update that permanently removes VNC access from the controller. Users should download and apply this update from: https://www.eppendorf.com/software-downloads. https://www.eppendorf.com/software-downloads Mitigation All affected BioFlo 320 systems always shipped with Virtual Network Computing (VNC) disabled by default, and VNC can only be enabled locally at the tower. Eppendorf has removed VNC configuration information from all current documentation, so it no longer appears in BioFlo 320 Operating Manuals. Mitigation Eppendorf recommends user do the following: Verify that VNC is disabled on the controller Enable security so that only Admin and Supervisor roles can change VNC settings Install Version 5.0 Software as soon as possible Relevant CWE: CWE-259 Use of Hard-coded Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments BIO-ISAC reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-26 Date Revision Summary 2026-05-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-9082 Drupal Core SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-9082 Drupal Core SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

ABB Terra AC Wallbox

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC Wallbox are affected: Terra AC…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC Wallbox are affected: Terra AC wallbox (JP) <=1.8.33, 1.8.36 (CVE-2025-10504, CVE-2025-12142, CVE-2025-12143) CVSS Vendor Equipment Vulnerabilities v3 6.1 ABB ABB Terra AC Wallbox Heap-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-10504 There is potential risk to pollute the memory when developing apps which has used to communicate with charger according to self-defined protocol if developers don’t strictly follow the field length which has not been validated in firmware. View CVE Details Affected Products ABB Terra AC Wallbox Vendor: ABB Product Version: ABB Terra AC wallbox (JP) <=1.8.33 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience. Mitigation To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C CVE-2025-12142 There is potential risk of polluting the BSS memory when developing apps which are used to communicate with charger via Bluetooth according to self-defined protocol if developers configure an unexpected length of bin files. View CVE Details Affected Products ABB Terra AC Wallbox Vendor: ABB Product Version: ABB Terra AC wallbox (JP) <=1.8.33 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience. Mitigation To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger. Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C CVE-2025-12143 There is potential risk of polluting the stack memory when developing a customized OCPP key of “Ran-domDelay“ in backend and configuring an unexpected number in the field. View CVE Details Affected Products ABB Terra AC Wallbox Vendor: ABB Product Version: ABB Terra AC wallbox (JP) <=1.8.33 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product version; apply the following update depending on product variant: Terra AC wallbox (JP) 1.8.36 ABB recommends that customers apply the update at earliest convenience. Mitigation To attack with this kind of message, hackers must hijack Bluetooth first and then can send messages. Because the communication messages between BLE and charger have been encrypted. In theory, there is no way to attack the charger. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C Acknowledgments ABB PSIRT reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A8107 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-09-16 Date Revision Summary 2025-09-16 1 Initial version. 2025-09-28 2 DocumentID update 2025-09-28 3 Minor corrections 2025-10-09 4 CVSS update 2025-10-27 5 CVE update 2025-11-28 6 CVE update 2025-11-28 7 Fixed Version update 2026-05-21 8 Initial CISA Republication of ABB PSIRT 9AKK108471A8107 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB B&R Automation Studio

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution. The following versions of ABB B&R Automation Studio are affected: B&R Automation Studio <6.5, 6.5 (CVE-2025-6965, CVE-2025-3277, CVE-2023-7104, CVE-2022-35737, CVE-2020-15358, CVE-2020-13632, CVE-2020-13631, CVE-2020-13630, CVE-2020-13435, CVE-2020-13434, CVE-2020-11656, CVE-2020-11655, CVE-2019-19646, CVE-2019-19645, CVE-2019-8457, CVE-2018-20506, CVE-2018-20505, CVE-2018-20346, CVE-2018-8740, CVE-2017-10989, CVE-2016-6153, CVE-2015-6607, CVE-2015-5895, CVE-2015-3717, CVE-2015-3416) CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB B&R Automation Studio Numeric Truncation Error, Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, NULL Pointer Dereference, Incorrect User Management, Use After Free, Integer Overflow or Wraparound, Improper Check for Unusual or Exceptional Conditions, Uncontrolled Recursion, Out-of-bounds Read, Improper Input Validation, Exposure of Sensitive Information to an Unauthorized Actor, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-6965 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-197 Numeric Truncation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2025-3277 An integer overflow vulnerability exists in SQLite's concat_ws() function that can lead to a massive heap buffer overflow. When triggered, the integer overflow results in a truncated size value being used for buffer allocation, while the original untruncated size is used for writing the resulting string, causing a heap buffer overflow of approximately 4GB. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2023-7104 A vulnerability was found in SQLite SQLite3 up to 3.43.0 and classified as critical. This issue affects the function sessionReadRecord of the file ext/session/sqlite3session.c of the component make alltest Handler. The manipulation leads to heap-based buffer overflow. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C CVE-2022-35737 SQLite 1.0.12 through 3.39.x before 3.39.2 sometimes allows an array-bounds overflow if billions of bytes are used in a string argument to a C API. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-15358 In SQLite before 3.32.3, select.c mishandles query-flattener optimization, leading to a multiSelectOrderBy heap overflow because of misuse of transitive properties for constant propagation. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-13632 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 5.5 MEDIUM CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-13631 SQLite before 3.32.0 allows a virtual table to be renamed to the name of one of its shadow tables, related to alter.c and build.c. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-286 Incorrect User Management Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C CVE-2020-13630 ext/fts3/fts3.c in SQLite before 3.32.0 has a use-after-free in fts3EvalNextRow, related to the snippet feature. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.0 7 HIGH CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2020-13435 SQLite through 3.32.0 has a segmentation fault in sqlite3ExprCodeTarget in expr.c. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-13434 SQLite through 3.32.0 has an integer overflow in sqlite3_str_vappendf in printf.c. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.0 5.5 MEDIUM CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-11656 In SQLite through 3.31.1, the ALTER TABLE implementation has a use-after-free, as demonstrated by an ORDER BY clause that belongs to a compound SELECT statement. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2020-11655 SQLite through 3.31.1 allows attackers to cause a denial of service (segmentation fault) via a malformed window-function query because the AggInfo object's initialization is mishandled. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2019-19646 pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2019-19645 alter.c in SQLite through 3.30.1 allows attackers to trigger infinite recursion via certain types of self-referential views in conjunction with ALTER TABLE statements. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-674 Uncontrolled Recursion Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2019-8457 SQLite3 from 3.6.0 to and including 3.27.2 is vulnerable to heap out-of-bound read in the rtreenode() function when handling invalid rtree tables. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2018-20506 SQLite before 3.25.3, when the FTS3 extension is enabled, encounters an integer overflow (and resultant buffer overflow) for FTS3 queries in a "merge" operation that occurs after crafted changes to FTS3 shadow tables, allow-ing remote attackers to execute arbitrary code by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases). This is a different vulnerability than CVE-2018-20346. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.1 HIGH CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2018-20505 SQLite 3.25.2, when queries are run on a table with a malformed PRIMARY KEY, allows remote attackers to cause a denial of service (application crash) by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases). View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2018-20346 SQLite before 3.25.3, when the FTS3 extension is enabled, encounters an integer overflow (and resultant buffer overflow) for FTS3 queries that occur after crafted changes to FTS3 shadow tables, allowing remote attackers to execute arbitrary code by leveraging the ability to run arbitrary SQL statements (such as in certain WebSQL use cases), aka Magellan. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.1 HIGH CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2018-8740 In SQLite through 3.22.0, databases whose schema is corrupted using a CREATE TABLE AS statement could cause a NULL pointer dereference, related to build.c and prepare.c. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2017-10989 The getNodeSize function in ext/rtree/rtree.c in SQLite through 3.19.3, as used in GDAL and other products, mis-handles undersized RTree blobs in a crafted database, leading to a heap-based buffer over-read or possibly un-specified other impact. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.0 9.8 CRITICAL CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2016-6153 There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.0 5.9 MEDIUM CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C CVE-2015-6607 SQLite before 3.8.9, as used in Android before 5.1.1 LMY48T, allows attackers to gain privileges via a crafted application, aka internal bug 20099586. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-286 Incorrect User Management Metrics CVSS Version Base Score Base Severity Vector String 3.0 3.7 LOW CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C CVE-2015-5895 Multiple unspecified vulnerabilities in SQLite before 3.8.10.2, as used in Apple iOS before 9, have unknown im-pact and attack vectors. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-200 Exposure of Sensitive Information to an Unauthorized Actor Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CVE-2015-3717 Multiple buffer overflows in the printf functionality in SQLite, as used in Apple iOS before 8.4 and OS X before 10.10.4, allow remote attackers to execute arbitrary code or cause a denial of service (application crash) via un-specified vectors. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2015-3416 The sqlite3VXPrintf function in printf.c in SQLite before 3.8.9 does not properly handle precision and width values during floating-point conversions, which allows context-dependent attackers to cause a denial of service (integer overflow and stack-based buffer overflow) or possibly have unspecified other impact via large integers in a crafted printf function call in a SELECT statement. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB B&R Automation Studio <6.5 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for advice on how to keep your system secure. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.8 HIGH CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C Acknowledgments ABB PSIRT reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by B&R. B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT SA25P007 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-18 Date Revision Summary 2026-02-18 1 Initial version. 2026-05-21 2 Initial CISA Republication of ABB PSIRT SA25P007 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB B&R PCs

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. A network attacker could exploit the vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. The following versions of ABB B&R PCs are affected: APC4100 <1.09,…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. A network attacker could exploit the vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. The following versions of ABB B&R PCs are affected: APC4100 <1.09, 1.09 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) APC910 <=1.25 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) C80 <1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) MPC3100 <1.24, 1.24 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) PPC1200 <1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) PPC900 <2.16, 2.16 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) APC2200 <1.35, 1.35 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) PPC2200 <1.35, 1.35 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) APC3100 <1.45, 1.45 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) PPC3100 <1.45, 1.45 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB B&R PCs Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer, Loop with Unreachable Exit Condition ('Infinite Loop'), Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2023-45229 EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing the IA_NA or IA_TA option in a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C CVE-2023-45230 EDK2's Network Package is susceptible to a buffer overflow vulnerability via a long server ID option in DHCPv6 client. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C CVE-2023-45231 EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing Neighbor Discovery Redirect message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C CVE-2023-45232 EDK2's Network Package is susceptible to an infinite loop vulnerability when parsing unknown options in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2023-45233 EDK2's Network Package is susceptible to an infinite loop vulnerability when parsing a PadN option in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C CVE-2023-45234 EDK2's Network Package is susceptible to a buffer overflow vulnerability when processing DNS Servers option from a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C CVE-2023-45235 EDK2's Network Package is susceptible to a buffer overflow vulnerability when handling Server ID option from a DHCPv6 proxy Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:P/RL:O/RC:C CVE-2023-45236 EDK2's Network Package is susceptible to a predictable TCP Initial Sequence Number. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N/E:P/RL:O/RC:C CVE-2023-45237 EDK2's Network Package is susceptible to a predictable TCP Initial Sequence Number. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality. View CVE Details Affected Products ABB B&R PCs Vendor: ABB Product Version: ABB APC4100 <1.09, ABB APC910 <=1.25, ABB C80 <1.14, ABB MPC3100 <1.24, ABB PPC1200 <1.14, ABB PPC900 <2.16, ABB APC2200 <1.35, ABB PPC2200 <1.35, ABB APC3100 <1.45, ABB PPC3100 <1.45 Product Status: fixed, known_affected Remediations Vendor fix The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Deactivate the vulnerable component - The vulnerabilities exist in the Preboot eXecution Environment (PXE) of the UEFI firmware. If this functionality is not needed, it is recommended to disable it in the UEFI settings, thus making the vulnerabilities not exploitable. Limit accessibility - If PXE functionality is required, users should tightly restrict network traffic to legitimate users and block illegitimate PXE traffic, specifically related to IPv6. For instance, by blocking IPv6 network traffic on the control network firewall. https://help.br-automation.com/#/en/6/cyber-security/defense-in-depth-for-br-products/reference_architecture.html Refer to section “General security recommendations” for further advise on how to keep your system secure. Relevant CWE: CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C Acknowledgments ABB PSIRT reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by B&R. B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What is the scope of the vulnerabilities? - A network attacker who successfully exploited these vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. In worst case, these vulnerabilities can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability. What causes the vulnerabilities? - The vulnerabilities are caused by usage of vulnerable UEFI firmware in some B&R xPCs. What is a B&R xPC? - A B&R xPC is an industrial PC (IPC) designed for use in industrial environments and is built to handle more demanding conditions than a standard PC. They often feature robust construction, resistance to dust and moisture, extended temperature ranges, and other specifications suited for industrial applications. What might an attacker use the vulnerabilities to do? - A network attacker who successfully exploited the vulnerabilities could execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. How could an attacker exploit the vulnerabilities? - An attacker could try to exploit the vulnerabilities by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerabilities be exploited remotely? - Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. What does the update do? - The update removes the vulnerabilities in the TCP/IP stack used by the UEFI firmware. When this security advisory was issued, had these vulnerabilities been publicly disclosed? - Yes, these vulnerabilities have been publicly disclosed. When this security advisory was issued, had B&R received any reports that this vulnerability was being exploited on B&R products? - No, B&R had not received any information indicating that this vulnerability had been exploited on B&R products when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT SA24P003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-29 Date Revision Summary 2026-01-29 1 Initial version. 2026-05-21 2 Initial CISA Republication of ABB PSIRT SA24P003 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-34291 Langflow Origin Validation Error Vulnerability CVE-2026-34926 Trend Micro Apex One (On-Premise) Directory Traversal Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-34291 Langflow Origin Validation Error Vulnerability CVE-2026-34926 Trend Micro Apex One (On-Premise) Directory Traversal Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Hitachi Energy GMS600

View CSAF Summary Hitachi Energy is aware of the vulnerability, CVE-2022-4304 in the OSS component OpenSSL, that affects the GMS600 versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original…
Read full source summary
View CSAF Summary Hitachi Energy is aware of the vulnerability, CVE-2022-4304 in the OSS component OpenSSL, that affects the GMS600 versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. For immediate mitigation /workaround information, please refer to the General Mitigation Factors/Workarounds The following versions of Hitachi Energy GMS600 are affected: GMS600 vers:GMS600/>=1.3.0|<=1.3.1 (CVE-2022-4304) CVSS Vendor Equipment Vulnerabilities v3 5.9 Hitachi Energy Hitachi Energy GMS600 Observable Discrepancy Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2022-4304 A timing-based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. View CVE Details Affected Products Hitachi Energy GMS600 Vendor: Hitachi Energy Product Version: GMS600 versions 1.3.0 and 1.3.1 Product Status: known_affected Remediations Vendor fix Upgrade to version 1.3.2 Relevant CWE: CWE-203 Observable Discrepancy Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Hitachi Energy Internal Team reported this vulnerability to CISA Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations such as enforcing ingress IP allowlisting and applying traffic rate limiting in accordance with the operational security policy can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. SSVC SSVCv2/E:N/A:Y/2026-04-22T13:37:14Z/ Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000159 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2023-06-27 Date Revision Summary 2023-06-27 1 Initial public release. 2026-04-28 2 Updated fixed version. 2026-05-21 3 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000159 advisory Legal Notice and Terms of Use