Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.
This page is an archived snapshot of the CISA Advisories feed collected on Jun 10, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
View CSAF Summary Successful exploitation of this vulnerability may grant full unauthorized access to camera feeds and settings. The following versions of KMW CCTV Security Cameras are affected: KM-IP521 IPCAM_V4.04.91.230307 KM-IP421 IPCAM_V4.04.53.210416 CVSS Vendor Equipment Vulnerabilities v3 9.1 KMW KMW CCTV Security Cameras Unverified Password Change Background Critical Infrastructure Sectors: Commercial…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may grant full unauthorized access to camera feeds and settings. The following versions of KMW CCTV Security Cameras are affected: KM-IP521 IPCAM_V4.04.91.230307 KM-IP421 IPCAM_V4.04.53.210416 CVSS Vendor Equipment Vulnerabilities v3 9.1 KMW KMW CCTV Security Cameras Unverified Password Change Background Critical Infrastructure Sectors: Commercial Facilities, Government Services and Facilities, Critical Manufacturing, Financial Services, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Romania Vulnerabilities Expand All + CVE-2026-5386 The affected product is vulnerable to a critical unauthenticated password reset. This flaw allows an attacker to remotely reset the administrator password to a known value without authentication, granting full access to the camera feeds and settings. View CVE Details Affected Products KMW CCTV Security Cameras Vendor: KMW Product Version: KMW KM-IP521: IPCAM_V4.04.91.230307, KMW KM-IP421: IPCAM_V4.04.53.210416 Product Status: known_affected Remediations Mitigation KMW has issued a firmware update to address this vulnerability. The firmware update can be found at https://main.kmw.ro/pub/Firmware/521_421.zip. https://main.kmw.ro/pub/Firmware/521_421.zip Vendor fix KM-IP421 - will lose the cloud authorization after this update so users will need to contact customer support to re-authorize the P2P connection. Mitigation KMW recommends connecting surveillance equipment on a separate network, allow only specific devices access to the internet, check for firmware updates regularly, and use cloud connections responsibly. Mitigation If there are any issues customers are encouraged to contact KMW directly. Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments Reporter Name(s): Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain administrator rights or execute code on the affected device. The following versions of XCharge C6 are affected: C6 CVSS Vendor Equipment Vulnerabilities v3 9.8 XCharge XCharge C6 Download of Code Without Integrity Check, Stack-based Buffer Overflow, Initialization of a Resource with an Insecure Default Background…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain administrator rights or execute code on the affected device. The following versions of XCharge C6 are affected: C6 CVSS Vendor Equipment Vulnerabilities v3 9.8 XCharge XCharge C6 Download of Code Without Integrity Check, Stack-based Buffer Overflow, Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9037 A firmware update mechanism in the affected charging controller fails to validate the authenticity of firmware packages delivered through the device's management interface. Because cryptographic signatures are not verified, an attacker with the ability to interfere with or impersonate the management channel could cause the device to install an unauthorized firmware package. This condition could allow execution of unauthorized code with high privileges on the device, View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-494 Download of Code Without Integrity Check Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-9038 A stack-based buffer overflow vulnerability in the charging controller's signal-processing logic allows an attacker with physical access to the charging interface to supply message fields that exceed expected bounds. Because the input is not sufficiently validated, memory corruption may occur, which can lead to execution of unauthorized code with elevated privileges. View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-9039 A configuration weakness in the device's remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access. View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Lionel R. Saposnik of SaiFlow reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker gaining administrator access to the device. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter are affected: USR-W610 RS232/485 to Wi-Fi/Ethernet Converter 7.03T.07 CVSS Vendor Equipment Vulnerabilities v3 9.8 Jinan USR IOT Technology Limited (PUSR) Jinan USR IOT…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker gaining administrator access to the device. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter are affected: USR-W610 RS232/485 to Wi-Fi/Ethernet Converter 7.03T.07 CVSS Vendor Equipment Vulnerabilities v3 9.8 Jinan USR IOT Technology Limited (PUSR) Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-7786 The device firmware contains plaintext administrative credentials embedded in the firmware image. These credentials can be extracted through firmware analysis and used to authenticate to device services. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter: 7.03T.07 Product Status: known_affected Remediations Mitigation Jinan USR IOT Technology Limited (PUSR) did not respond to CISA's attempts at coordination. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Arun Mane and Omkar Mali reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker gaining administrator access to the device. The following versions of MacGregor Voyage Data Recorder (VDR) G4e are affected: MacGregor Voyage Data Recorder (VDR) G4e <V5.250 CVSS Vendor Equipment Vulnerabilities v3 8.3 Danelec MacGregor Voyage Data Recorder (VDR) G4e Use of Default Credentials, Insufficiently Protected…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker gaining administrator access to the device. The following versions of MacGregor Voyage Data Recorder (VDR) G4e are affected: MacGregor Voyage Data Recorder (VDR) G4e <V5.250 CVSS Vendor Equipment Vulnerabilities v3 8.3 Danelec MacGregor Voyage Data Recorder (VDR) G4e Use of Default Credentials, Insufficiently Protected Credentials, Use of Password Hash With Insufficient Computational Effort, Use of Hard-coded Credentials, Files or Directories Accessible to External Parties Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Denmark Vulnerabilities Expand All + CVE-2026-42941 The VDR device includes a default username and password, with no enforced password change. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-1392 Use of Default Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 8.7 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-42951 An authenticated user can download a backup of the device which includes account data and password hashes. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 5.9 MEDIUM CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-44611 Passwords are stored with a hashing method which limits password length and is susceptible to brute force attacks. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational Effort Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 5.9 MEDIUM CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-42929 The device includes default accounts with hard-coded credentials. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 8.7 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-40425 The administrator account for the web interface can directly edit sensitive files related to authentication, potentially changing the root password. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.7 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:L 4.0 6.9 MEDIUM CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Andrew Tierney of Pen Test Partners reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm. The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected: Frontier X Android application vers<v15.0.0 Frontier X IOS application vers<v25.0.0…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm. The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected: Frontier X Android application vers<v15.0.0 Frontier X IOS application vers<v25.0.0 Frontier X2 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 8.8 Fourth Frontier Fourth Frontier Frontier X Mobile Application, Frontier X2 Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-5768 The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application. View CVE Details Affected Products Fourth Frontier Frontier X Mobile Application, Frontier X2 Vendor: Fourth Frontier Product Version: Fourth Frontier Frontier X Android application: <v15.0.0, Fourth Frontier Frontier X IOS application: <v25.0.0, Fourth Frontier Frontier X2: vers:all/* Product Status: known_affected Remediations Mitigation Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance. https://fourthfrontier.com/pages/contact-usl. https://fourthfrontier.com/pages/contact-us Mitigation Frontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Shakir Zari and Jerin Sunny reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed The following versions of ABB Busch-Welcome 2 Wire Door Opener Actuator are affected: Switch Actuator 4 DU vers:all/* Switch actuator, door/light 4 DU vers:all/*…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed The following versions of ABB Busch-Welcome 2 Wire Door Opener Actuator are affected: Switch Actuator 4 DU vers:all/* Switch actuator, door/light 4 DU vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Busch-Welcome 2 Wire Door Opener Actuator Active Debug Code Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7705 Authentication bypass due to compatibility mode enabled by default View CVE Details Affected Products ABB Busch-Welcome 2 Wire Door Opener Actuator Vendor: ABB Product Version: Switch Actuator 4 DU -83330 - All Versions, Switch actuator, door/light 4 DU -83330-500 - All Versions Product Status: known_affected Remediations Mitigation The following actions need to be executed on premise where the respective Busch-Welcome® System is installed: • While the Busch-Welcome® System is in operation, toggle the mode switch on the product from “Door-Open” - to “Light” – Mode, wait one second and switch back to “Door-Open” - Mode. • Restart the Busch-Welcome® System with a Power reset (mains power off and on again). By executing the above steps, the system will recalibrate itself during boot up and will correct the misconfiguration automatically. ABB recommends that customers apply the above listed actions at the earliest convenience. Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors ABB recommends double check the system handbook of a Busch-Welcome® two wire system regarding security advises for the correct installation. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A4556 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-07-21 Date Revision Summary 2025-07-21 1 Initial version. 2026-05-28 2 Initial CISA Republication of ABB PSIRT 9AKK108471A4556 advisory Legal Notice and Terms of Use
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-8398 Daemon Tools Lite Embedded Malicious Code Vulnerability CVE-2026-45321 TanStack Unspecified Vulnerability CVE-2026-48027 Nx Console Embedded Malicious Code Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-8398 Daemon Tools Lite Embedded Malicious Code Vulnerability CVE-2026-45321 TanStack Unspecified Vulnerability CVE-2026-48027 Nx Console Embedded Malicious Code Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
View CSAF Summary ABB became aware of an internally discovered vulnerability in the MConfig product versions listed as affected in the advisory. An attacker with access to local networks who successfully exploits vulnerability could have access to application’s sensitive information. ABB strongly advises customers to update MConfig with latest software version. The following versions of ABB LVS MConfig are affected:…
Read full source summary
View CSAF Summary ABB became aware of an internally discovered vulnerability in the MConfig product versions listed as affected in the advisory. An attacker with access to local networks who successfully exploits vulnerability could have access to application’s sensitive information. ABB strongly advises customers to update MConfig with latest software version. The following versions of ABB LVS MConfig are affected: LVS <=1.4.9.21 CVSS Vendor Equipment Vulnerabilities v3 7.4 ABB ABB LVS MConfig Cleartext Storage of Sensitive Information in Memory Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-9970 During the runtime of the MConfig Software application, an attacker can export the memory dump file into the operating system. If passwords are stored in plain text in memory, they will be included in these dump files. If such dump files are mishandled, attackers could obtain them and extract the passwords. View CVE Details Affected Products ABB LVS MConfig Vendor: ABB Product Version: MConfig Version <=1.4.9.21 Product Status: fixed, known_affected Remediations Vendor fix The vulnerability is resolved in the following product versions: MConfig version 1.4.9.22 ABB advises users to update their devices to the latest software version. Additionally, ABB recommends implementing defensive measures to reduce the risk of vulnerability exploitation, as outlined in the product instruction manual. Please refer to the section “Mitigation factors” for more information Relevant CWE: CWE-316 Cleartext Storage of Sensitive Information in Memory Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H/E:P/RL:O/RC:C/CR:L/IR:L/AR:L Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third-party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. In case customer cannot upgrade the firmware or it is not feasible then please immediately apply mitigating factors mentioned in “General security recommendations”. Frequently asked questions What causes the vulnerability? The vulnerability is caused by code defect allowing the attacker to extract the sensitive information such as user credentials from memory dump of the application. Please refer to Vulnerability severity and details for further details. What is MConfig ? MConfig is the parameterizing software for ABB LV switchgear components such as motor and feeder controller, operation panel, temperature monitoring solutions and protocol converter. The components are physically installed in a low voltage switchgear located in switch rooms that require authority to access. To run this software on a host machine (computer), the operating system should be Win11 or later version. What might an attacker use the vulnerability to do? If the mentioned vulnerability has been successfully exploited by an attacker, this could allow the attacker to extract sensitive information such as user credentials. With user credentials and access to a host machine with MConfig installed, and access to the switch room with components installed in a switchgear, the attacker can modify the setting of the components potentially compromising its correct operation. How could an attacker exploit vulnerability? An attacker with host machine physical access could, after a user log into MConfig, exploit a vulnerability by exporting a memory dump during runtime, potentially exposing the user's password. Could vulnerability be exploited remotely? The vulnerability can only be exploited if an attacker has physical access to the host machine with MConfig software. What does the update do? MConfig version V1.4.9.22 update has fix for the vulnerability mentioned in Vulnerability severity and details section. The measures below were implemented to fix the vulnerability: • Clear any authentication-related memory data after a successful login. • Hash the passwords in SHA256 Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 4TZ00000006008 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-10-08 Date Revision Summary 2025-10-08 1 Initial version. 2026-05-26 2 Initial CISA Republication of ABB PSIRT 4TZ00000006008 advisory Legal Notice and Terms of Use
View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical…
Read full source summary
View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7745 Sending unsupported function codes to the AC500 V2 Modbus server might result in invalid responses. Fragments of previous responses might be added to the end of the response. View CVE Details Affected Products ABB AC500 V2 Vendor: ABB Product Version: ABB AC500 V2 <=2.5.2 Product Status: fixed, known_affected Remediations Vendor fix The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N Acknowledgments Reid Wightman of Dragos. Inc reported these vulnerabilities to Schneider Electric. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Regarding this vulnerability it is recommended to • Do not use the Modbus server for sending any sensitive data, as fragments might be accessible even after the initial sending of the response • Only use supported Modbus function codes, as invalid responses to unsupported function codes might have negative effects on the requesting Modbus client. Refer to section “General security recommendations” for further advise on how to keep your system secure. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 3ADR011432 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-07-23 Date Revision Summary 2025-07-23 1 Initial version. 2026-05-22 2 Minor correction to the affected product version in the product tree. 2026-05-26 3 Initial CISA Republication of ABB PSIRT 3ADR011432 advisory Legal Notice and Terms of Use
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox (UL40/80A) <=1.8.32, 1.8.33 Terra AC wallbox (UL32A) <=1.8.2, 1.8.34 Terra AC wallbox (MID/ CE) <=1.8.32, 1.8.34 Terra AC wallbox (JP) <=1.8.2, 1.8.34 CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Terra AC Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-5517 There is potential risk to pollute the memory when a specially crafted OCPP message may be sent to a target vulnerable charger by exploiting unencrypted communication to the Charging Station Management System (CSMS) or fully remotely from its CSMS server. View CVE Details Affected Products ABB Terra AC Vendor: ABB Product Version: ABB Terra AC wallbox (UL40/80A) <=1.8.32, ABB Terra AC wallbox (UL32A) <=1.8.2, ABB Terra AC wallbox (MID/ CE) Terra AC MID <=1.8.32, ABB Terra AC wallbox (JP) <=1.8.2 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the product versions listed as fixed in the advisory. Terra AC wallbox (UL40/80A) 1.8.33 Terra AC wallbox (UL32A) 1.8.34 Terra AC MID 1.8.34 Terra AC Juno CE 1.8.34 Terra AC PTB 1.8.33 Terra AC wallbox (JP) 1.8.34 Additionally, we strongly recommend not use unsafe mode(http) to connect your charger to your backend even though OCPP is allowed to do in this way, which absolutely could be attacked by malicious man or organization as a common knowledge. ABB recommends that customers apply the update at earliest convenience. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C Acknowledgments Itai Shmueli of Saiflow reported this vulnerability to Schneider Electric. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors To attack with this kind of message, hackers must hijack CSMS (OCPP backends) first and then can send messages, OR the way to OCPP backend is unsafe itself (http) which can cause any kind of attack behavior and known as a common knowledge. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workarounds Make sure OCPP backend that chargers are connected is strictly secured to avoid any kind of at-tack especially the communication relevant components. Use https(TLS) as basic communication foundation between charger and OCPP backend instead of http. Frequently asked questions What causes the vulnerability? The vulnerability is caused by firmware which it didn’t limit the length of OCPP field in certain case. What is Terra AC wallbox? Terra AC wallbox is a Level 2 Electric Vehicle charger. What might an attacker use the vulnerability to do? An attacker who successfully exploited this vulnerability could cause the affected system node to take control of the charger to response wrong messages, Denial-of-Service, compromised internal state, and possibly remote code execution. How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by sending a specially crafted OCPP message to chargers via OCPP backend(CSMS), which could be done remotely. This would require that the attacker has access to the system network and hijack the API of sending message OR hijack the network data directly if the charger is connected with unsafe http mode. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Can functional safety be affected by an exploit of this vulnerability? The charger potentially is running with unpredictable mode, including Denial-of-Service, compromised internal state, and possibly remote code execution. What does the update do? The update removes the vulnerability by modifying the validation rules of receiving data from OCPP backend. When this security advisory was issued, had this vulnerability been publicly disclosed? No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A8948 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-10-20 Date Revision Summary 2025-10-20 1 Initial version. 2025-10-21 2 Final version 2026-05-26 3 Initial CISA Republication of ABB PSIRT 9AKK108471A8948 advisory Legal Notice and Terms of Use