· CISA Cybersecurity Advisory

CISA Urges Hardening Fortinet Devices After Reports of Credential Exposure

CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. To defend against…
Read full source summary
CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. To defend against this malicious cyber activity, CISA urges impacted Fortinet customers with FortiGate appliances and associated secure sockets layer (SSL) VPN gateways to immediately: Terminate sessions and reset credentials. Terminate all active SSL VPN and administrative sessions. Reset all Fortinet VPN and administrative passwords, especially on internet-facing systems, and enforce strong password policies. Ensure secure credential storage. Confirm your organization’s use of the Password-Based Key Derivation Function 2 (PBKDF2) algorithm to store administrator credentials and remove weaker legacy hashes per Fortinet’s guidance (see, Fortinet's Technical Tip: Enforcing PBKDF2 as hash function for administrator accounts in FortiOS v7.2.11 and later). Review logs. Review firewall, VPN, authentication, and domain controller logs for lateral movement, unusual access, suspicious accounts, or unauthorized configuration changes. Enable phishing-resistant multifactor authentication (MFA). Require phishing-resistant MFA on all remote access and administrative accounts and ensure it is enforced on all external gateways and administrative interfaces. Reduce the attack surface and lock down management access. Ensure the administration of your firewall is inaccessible from the public internet; restrict Fortinet management interfaces to trusted internal networks; and remove or disable any unauthorized or unnecessary accounts. See the following resources to determine your organization’s potential impact and find additional guidance on the credentials compromised: Tech Times: Fortinet FortiGate Credential Leak Hits 73,932 Firewalls: Half the Internet-Facing Fleet SOCRadar: FortiBleed: The Compromise of 80,000+ Fortinet Firewalls Hudson Rock: FortiBleed: 75,000 Fortinet Firewalls Compromised: Global Enterprises Exposed – Claim Your Ethical Disclosure Arctic Wolf: Active FortiBleed Campaign Impacting Fortinet Devices Across 194 Countries Fortinet: Attacks at the Speed of AI Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.
· CISA Cybersecurity Advisory

AzeoTech DAQFactory

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 (CVE-2026-12390) CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion') Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 (CVE-2026-12390) CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12390 In AzeoTech DAQFactory versions 21.1 and prior, a Type Confusion vulnerability can be exploited by an attacker using specially crafted .ctl files which can result in code execution. View CVE Details Affected Products AzeoTech DAQFactory Vendor: AzeoTech Product Version: AzeoTech DAQFactory: <=21.1 Product Status: known_affected Remediations Mitigation Users are discouraged from using documents from unknown/untrusted sources. Mitigation Users are encouraged to store .ctl files in a folder only writeable by admin-level users. Mitigation Users are encouraged to operate in "Safe Mode" when loading documents that have been out of their control. Mitigation Users are encouraged to apply a document editing password to their documents. Relevant CWE: CWE-843 Access of Resource Using Incompatible Type ('Type Confusion') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Rocco Calvi (@TecR0c) of TecSecurity reported this vulnerability to CISA rgod of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS Vendor Equipment Vulnerabilities v3 6.5 Apollo Pharmacy Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information, Missing Authorization Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: India Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-50034 An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status: known_affected Remediations Mitigation Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us. https://www.apollopharmacy.in/contact-us Mitigation CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology. https://www.cisa.gov/news-events/news/understanding-bluetooth-technology Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-52866 An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status: known_affected Remediations Mitigation Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us. https://www.apollopharmacy.in/contact-us Mitigation CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology. https://www.cisa.gov/news-events/news/understanding-bluetooth-technology Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP vers:all/* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. View CVE Details Affected Products Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: vers:all/* Product Status: known_affected Remediations No fix planned There are no plans to release fixed version for MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. For customers of MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf", and take the actions described there. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf Mitigation For customers, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to "13.1 IP Filter Function" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html." https://www.mitsubishielectric.com/fa/download/index.html Mitigation For customers, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-440 Expected Behavior Violation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Mitsubishi Electric discovering this vulnerability Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-003 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric MELSEC iQ-F Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series are affected: MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP <=1.000 (CVE-2026-8805) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F Series Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8805 An integer overflow or wraparound vulnerability exists in the EtherNet/IP function of MELSEC iQ-F Series EtherNet/IP module. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. View CVE Details Affected Products Mitsubishi Electric MELSEC iQ-F Series Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP: <=1.000 Product Status: known_affected Remediations Vendor fix Mitsubishi Electric is releasing fixed version 1.001 or later for MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP. Download the update file for the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-002_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to "13.1 IP Filter Function" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html." https://www.mitsubishielectric.com/fa/download/index.html Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Mitsubishi Electric reported this vulnerability to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-002 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-002 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided…
Read full source summary
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products are affected: Easergy MiCOM C264 vers:generic/<=D7.33 (CVE-2026-4827) Easergy MiCOM P139 vers:generic/<=P139.678.700 (CVE-2026-4827) Easergy MiCOM P437 vers:generic/<=P437.678.700 (CVE-2026-4827) Easergy MiCOM P439 vers:generic/<=P439.678.700 (CVE-2026-4827) Easergy MiCOM P532 vers:generic/<=P532.678.700 (CVE-2026-4827) Easergy MiCOM P539 vers:generic/<=P539.678.700 (CVE-2026-4827) Easergy MiCOM P631 vers:generic/<=P631.678.700 (CVE-2026-4827) Easergy MiCOM P632 vers:generic/<=P632.678.700 (CVE-2026-4827) Easergy MiCOM P633 vers:generic/<=P633.678.700 (CVE-2026-4827) Easergy MiCOM P634 vers:generic/<=P634.678.700 (CVE-2026-4827) Easergy MiCOM P633 P633.680.700 (CVE-2026-4827) Easergy MiCOM P634 P634.680.700 (CVE-2026-4827) Easergy MiCOM P138 vers:generic/<=P138.677.700 (CVE-2026-4827) Easergy MiCOM P436 vers:generic/<=P436.677.701 (CVE-2026-4827) Easergy MiCOM P438 vers:generic/<=P438.677.701 (CVE-2026-4827) Easergy MiCOM P638 vers:generic/<=P638.677.700 (CVE-2026-4827) Easergy MiCOM C434 vers:generic/<=C434.679.700 (CVE-2026-4827) EcoStruxure Power Automation System Gateway (EPAS-GTW) vers:intdot/<=6.4.616.200.100 (CVE-2026-4827) EcoStruxure Power Automation System User Interface (EPAS-UI) vers:intdot/<=3.0.3 (CVE-2026-4827) EcoStruxure Power Operation vers:generic/<=2022_CU6 (CVE-2026-4827) EcoStruxure Power Operation vers:generic/<=2024_CU2 (CVE-2026-4827) iPMFLS vers:intdot/<=64.2025.0.13 (CVE-2026-4827) PowerLogic P5 Protection Relay vers:intdot/<=02.502.103 (CVE-2026-4827) PowerLogic P7 Protection and Control Platform vers:intdot/<=02.002.002 (CVE-2026-4827) PowerLogic T300 vers:intdot/<=2.9.4 (CVE-2026-4827) PowerLogic T500 vers:intdot/<=11.08.02 (CVE-2026-4827) Saitel DP vers:intdot/<=11.06.36 () EasyLogic T150 (formerly Saitel DR) vers:intdot/<=11.06.30 () Easergy MiCOM C264 D7.34 () Easergy C5 vers:intdot/<=1.1.17 (CVE-2026-4827) Easergy C5 1.1.18 () Easergy MiCOM P139 version P139.678.700 () Easergy MiCOM P439 P439.678.700 () Easergy MiCOM P539 P539.678.700 () Easergy MiCOM P632 P632.678.700 () Easergy MiCOM P633 P633.680.701 () Easergy MiCOM P634 P634.680.701 () Easergy MiCOM P633 P633.678.700 () Easergy MiCOM P138 P138.677.701 () Easergy MiCOM C434 C434.679.700 () Saitel DR 11.06.31 () EcoStruxure Power Automation System Gateway (EPAS-GTW) 6.4.610.500.101 () EcoStruxure Power Automation Automation System User Interface (EPAS-UI) 3.0.4 () EcoStruxure Power Operation 2022_CU7 () EcoStruxure Power Operation (EPO) 2024_CU3 () iPMFLS 64.2025.0.14 () PowerLogic P5 Protection Relay 02.503.101 () PowerLogic P7 Protection and Control Platform 02.003.001 () PowerLogic T300 2.9.5 () PowerLogic T500 11.08.03 () Saitel DP 11.06.37 () Easergy MiCOM P40 Series vers:all/* (CVE-2026-4827) CVSS Vendor Equipment Vulnerabilities v3 8.3 Schneider Electric Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products Insufficient Entropy Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-4827 CWE-331 Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections. View CVE Details Affected Products Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products Vendor: Schneider Electric Product Version: Easergy MiCOM C264 Versions D7.33 and prior, Easergy MiCOM P139 version prior to P139.678.700, Easergy MiCOM P437 version prior to P437.678.700, Easergy MiCOM P439 version prior to P439.678.700, Easergy MiCOM P532 version prior to P532.678.700, Easergy MiCOM P539 version prior to P539.678.700, Easergy MiCOM P631 version prior to P631.678.700, Easergy MiCOM P632 version prior to P632.678.700, Easergy MiCOM P633 version prior to P633.678.700, Easergy MiCOM P634 version prior to P634.678.700, Easergy MiCOM P633 version P633.680.700, Easergy MiCOM P634 version P634.680.700 , Easergy MiCOM P138 version prior to P138.677.700, Easergy MiCOM P436 version prior to P436.677.701, Easergy MiCOM P438 version prior to P438.677.701, Easergy MiCOM P638 version prior to P638.677.700, Easergy MiCOM C434 version prior to C434.679.700, EcoStruxure Power Automation System Gateway (EPAS-GTW) Version 6.4.616.200.100 and prior, EcoStruxure Power Automation System User Interface (EPAS-UI) Version 3.0.3 and prior, EcoStruxure Power Operation (EPO) 2022 CU6 and prior, EcoStruxure Power Operation (EPO) 2024 CU2 and prior, iPMFLS Version 64.2025.0.13 and prior, PowerLogic P5 Protection Relay V02.502.103 and prior, PowerLogic P7 Protection and Control Platform V02.002.002 and prior, PowerLogic T300 Version 2.9.4 and prior, PowerLogic T500 Version 11.08.02 and prior, Easergy C5 Version 1.1.17 and prior, Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L and all firmware versions Product Status: fixed, known_affected Remediations Vendor fix Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required Vendor fix Version 1.1.18 of Easergy C5 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required Vendor fix Version P139.678.700 Easergy MiCOM P139 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P439.678.700 Easergy MiCOM P439 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P539.678.700 Easergy MiCOM P539 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P632.678.700 Easergy MiCOM P632 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P633.678.700 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P634.680.701 Easergy MiCOM P634 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P633.680.701 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P138.677.701 Easergy MiCOM P138 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version C434.679.700 Easergy MiCOM C434 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix HUe Firmware version 11.06.31 includes a fix for this vulnerability and is available for download here: . Contact Schneider Electric’s Customer Care Center to download this software. A reboot is needed to complete the firmware upgrade Vendor fix Version 6.4.610.500.101 of EPAS Gateway includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this software Vendor fix Version 3.0.4 of EPAS-UI includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this software. Vendor fix EPO 2022 CU 7 of EcoStruxure™ Power Operation includes a fix for this vulnerability and is available for download here: • https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2022-CU7-is-Now-Available/tdp/524787 Reboot needed: yes https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787 Vendor fix EPO 2024 CU 3 of EcoStruxure™ Power Operation includes a fix for this vulnerability and is available for download here: • https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2024-CU3-is-HERE/td-p/534769 Reboot needed: yes https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769 Vendor fix Version 64.2025.0.14 of iPMFLS includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version V02.503.101 of PowerLogic™ P5 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. Vendor fix Version V02.003.001 of PowerLogic™ P7 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. Vendor fix Version 2.9.5 of PowerLogic™ T300 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Vendor fix Version 11.08.03 of PowerLogic™ T500 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Vendor fix CPU866e Firmware version 11.06.37 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Mitigation Schneider Electric is establishing a remediation plan for all future versions of the following models of the Easergy MiCOM P30: P437 P532 P631 P634 P436 P438 P638 Future versions will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: • Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions Mitigation Schneider Electric is establishing a remediation plan for a future version of the Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L. P_ 4_ _ _ _ _ G_ _ _ _ _ M P_ 4_ _ _ _ _ H_ _ _ _ _ M P_ 4_ _ _ _ _ L _ _ _ _ _ M P_ 4_ _ _ _ _ G_ _ _ _ _ L P_ 4_ _ _ _ _ H_ _ _ _ _ L P_ 4_ _ _ _ _ L _ _ _ _ _ L A future version will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: • Ensure P40 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:• Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions. Relevant CWE: CWE-331 Insufficient Entropy Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-05-12 Date Revision Summary 2026-05-12 1 Original Release 2026-06-18 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-132-02 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Historian Site Edition

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00 (CVE-2025-36539) CVSS Vendor Equipment Vulnerabilities v3 7.7 Rockwell Automation Rockwell Automation FactoryTalk Historian Site Edition Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13036 An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: 11 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends the following: Mitigations and Workarounds for CVE-2025-13036: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and consider applying the available patch (BF32850) for their current version (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2025-44019 AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. Depending on the timing of the crash, data present in snapshots/write cache may be lost. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: <=11.00 Product Status: known_affected Remediations Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-248 Uncaught Exception Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N CVE-2025-36539 AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: <=11.00 Product Status: known_affected Remediations Mitigation Mitigations and Workarounds for CVE-2025-36539 & CVE-2025-44109: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and also consider the following: Monitor liveness of PI Network Manager and PI Archive Subsystem services. Set the PI Network Manager and PI Archive Subsystem services to automatically restart. Limit port 5450 access to trusted workstations and software. For a list of PI System firewall port requirements, see knowledge base article KB01162 - Firewall Port Requirements. For a starting point on PI system security best practices, see knowledge base article KB00833 - Best practices for securing your PI Server. Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-248 Uncaught Exception Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Republication of Rockwell Automation Security Advisory SD1773 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AVer PTC cameras

View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External Parties Background Critical Infrastructure Sectors: Government Services and Facilities, Commercial Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-40624 Improper input validation in AVer PTC500S, PTC115, PTC500+, and PTC115+ cameras may allow a remote, unauthenticated attacker to achieve arbitrary code execution via a specially crafted web request. View CVE Details Affected Products AVer PTC cameras Vendor: AVer Product Version: AVer PTC500S: vers:all/*, AVer PTC115: vers:all/*, AVer PTC500+: vers:all/*, AVer PTC115+: vers:all/* Product Status: known_affected Remediations Mitigation AVer has provided a firmware fix to address this vulnerability; users can find it at the following location: (https://presentation.aver.com/DownloadFile.aspx?n=6617|1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&t=ServiceDownload). https://presentation.aver.com/DownloadFile.aspx?n=6617%7C1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&t=ServiceDownload Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments fj016 reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EasyLogic T150 and Saitel DP

View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller…
Read full source summary
View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.31 (CVE-2026-6865) Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.36 (CVE-2026-6865) CVSS Vendor Equipment Vulnerabilities v3 7.1 Schneider Electric Schneider Electric EasyLogic T150 and Saitel DP Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-6865 CWE-22: Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal") vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing. View CVE Details Affected Products Schneider Electric EasyLogic T150 and Saitel DP Vendor: Schneider Electric Product Version: Schneider Electric Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions): vers:semver/<=11.06.31, Schneider Electric Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): vers:semver/<=11.06.36 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware (vers:semver/<=11.06.31) installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller includes a fix for this vulnerability and is available for download here: Mitigation Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes Mitigation Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware (vers:semver/<=11.06.36) installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): Version 11.06.37 of Saitel DP Remote Terminal Unit & Controller includes a fix for this vulnerability and is available for download here: Mitigation Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes Mitigation All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure strict credential controls, even for low privilege users. Mitigation Ensure isolation and credentials are in place, as per the product's security recommendations. Mitigation The following product versions have been fixed: Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller are fixed versions for CVE-2026-6865 Mitigation Firmware Version 11.06.37 installed on Saitel DP Remote Terminal Unit & Controller are fixed versions for CVE-2026-6865 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-03.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-132-03.json Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-12 Date Revision Summary 2026-05-12 1 Initial Publication 2026-06-18 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-132-03 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FLEX I/O EtherNet/IP Adapters

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access, account takeover, and cause loss of availability. The following versions of Rockwell Automation FLEX I/O EtherNet/IP Adapters are affected: 1794-AENTR V2.012 (CVE-2026-0646, CVE-2026-0647) 1794-AENTRXT V2.012 (CVE-2026-0646, CVE-2026-0647) CVSS Vendor Equipment Vulnerabilities v3 9.4 Rockwell…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access, account takeover, and cause loss of availability. The following versions of Rockwell Automation FLEX I/O EtherNet/IP Adapters are affected: 1794-AENTR V2.012 (CVE-2026-0646, CVE-2026-0647) 1794-AENTRXT V2.012 (CVE-2026-0646, CVE-2026-0647) CVSS Vendor Equipment Vulnerabilities v3 9.4 Rockwell Automation Rockwell Automation FLEX I/O EtherNet/IP Adapters Missing Release of Memory after Effective Lifetime, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-0646 A denial-of-service security issue exists within the 1794-AENTR adapter due to improper memory handling of CIP protocol requests. This vulnerability can result in the adapter faulting and losing connection to its associated I/O modules, requiring a manual reset to recover. View CVE Details Affected Products Rockwell Automation FLEX I/O EtherNet/IP Adapters Vendor: Rockwell Automation Product Version: Rockwell Automation 1794-AENTR: V2.012, Rockwell Automation 1794-AENTRXT: V2.012 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users update to 2.013 to resolve these vulnerabilities. Mitigation For more information, please visit Rockwell Automation's SD1775 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-0647 An improper authentication security issue exists within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device's embedded web server's availability. View CVE Details Affected Products Rockwell Automation FLEX I/O EtherNet/IP Adapters Vendor: Rockwell Automation Product Version: Rockwell Automation 1794-AENTR: V2.012, Rockwell Automation 1794-AENTRXT: V2.012 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users update to 2.013 to resolve these vulnerabilities. Mitigation For more information, please visit Rockwell Automation's SD1775 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H 4.0 8.8 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation Security Advisory SD1775 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP

View CSAF Summary Successful exploitation of this vulnerability could cause a denial-of-service condition that may result in a major nonrecoverable fault (MNRF). The following versions of Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP are affected: CompactLogix 5370 <=34.016 (CVE-2026-11317) Compact GuardLogix 5370 <=35.015 (CVE-2026-11317) ControlLogix 5570 <=35.015…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could cause a denial-of-service condition that may result in a major nonrecoverable fault (MNRF). The following versions of Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP are affected: CompactLogix 5370 <=34.016 (CVE-2026-11317) Compact GuardLogix 5370 <=35.015 (CVE-2026-11317) ControlLogix 5570 <=35.015 (CVE-2026-11317) GuardLogix 5570 36.012 (CVE-2026-11317) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP Improper Resource Shutdown or Release Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-11317 A denial of service security issue exists in the affected product. The security issue stems from a fault occurring when a crafted CIP message is sent. Devices with less memory are more likely to be affected. This can result in a major nonrecoverable fault (MNRF). A program download is required to recover. View CVE Details Affected Products Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370: <=34.016, Rockwell Automation Compact GuardLogix 5370: <=35.015, Rockwell Automation ControlLogix 5570: <=35.015, Rockwell Automation GuardLogix 5570: 36.012 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to update to the following versions: CompactLogix 5370: Versions 34.016 and later Vendor fix Compact GuardLogix 5370: Versions 35.015 and later Vendor fix ControlLogix 5570: Versions 36.012 and later Vendor fix GuardLogix 5570: Versions 37.011 and later Mitigation For more information, see Rockwell Automation Security Advisory SD1772 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1772.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1772.html Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation Security Advisory SD1772 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation RSLinx

View CSAF Summary Successful exploitation of this vulnerability can lead to a denial of service, where the application will become unresponsive and will not recover on its own. The following versions of RSLinx Classic Third-Party Vulnerability are affected: RSLinx Classic <=4.50.00 (CVE-2020-13573) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation RSLinx Classic Third-Party Vulnerability Out-of-bounds…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability can lead to a denial of service, where the application will become unresponsive and will not recover on its own. The following versions of RSLinx Classic Third-Party Vulnerability are affected: RSLinx Classic <=4.50.00 (CVE-2020-13573) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation RSLinx Classic Third-Party Vulnerability Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2020-13573 The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. View CVE Details Affected Products RSLinx Classic Third-Party Vulnerability Vendor: Rockwell Automation Product Version: Rockwell Automation RSLinx Classic: <=4.50.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends that customers using the affected software should upgrade to version 4.60.00 or later. Customers who are not able to upgrade to one of the corrected versions, should consider applying the available patch (BF31213) for their current version or applying the recommended security best practices. https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1774.html Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation Advisory SD1774 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Analytics PavilionX

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker executing privileged operations. The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected: FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272) CVSS Vendor Equipment Vulnerabilities v3 7 Rockwell Automation Rockwell Automation FactoryTalk Analytics PavilionX Missing Authorization Background…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker executing privileged operations. The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected: FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272) CVSS Vendor Equipment Vulnerabilities v3 7 Rockwell Automation Rockwell Automation FactoryTalk Analytics PavilionX Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-14272 A security issue was identified in Pavilion due to improper authorization enforcement in API endpoints. This vulnerability can allow an unauthorized actor to execute privileged operations, including user/role management and other administrative actions. View CVE Details Affected Products Rockwell Automation FactoryTalk Analytics PavilionX Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Analytics PavilionX: <7.01 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users update FactoryTalk Analytics PavilionX software to version 7.01 or later. The upgrade can be downloaded from the Rockwell Automation Download Center: https://www.rockwellautomation.com/en-us/support/product/product-downloads.html https://www.rockwellautomation.com/en-us/support/product/product-downloads.html Mitigation See Rockwell Automation's SD1777 advisory for more information: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L 4.0 8.3 HIGH CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation advisory SD1777 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation CompactLogix

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix are affected: CompactLogix 5370 L1 CompactLogix 5370 L2 CompactLogix 5370 L3 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation CompactLogix Improper Validation of Integrity Check Value, Exposure…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix are affected: CompactLogix 5370 L1 CompactLogix 5370 L2 CompactLogix 5370 L3 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation CompactLogix Improper Validation of Integrity Check Value, Exposure of Sensitive System Information to an Unauthorized Control Sphere Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-11694 A security issue exists within 1769 CompactLogix controllers due to the missing validation of sequence numbers and source IP addresses in the CIP protocol. This allows attacker to abuse the exposed Connection ID's visible on the web interface to perform denial-of-service attacks, resulting in a minor fault. View CVE Details Affected Products Rockwell Automation CompactLogix Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370 L1: <V38.011, Rockwell Automation CompactLogix 5370 L2: <V38.011, Rockwell Automation CompactLogix 5370 L3: <V38.011 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users update to V38.011 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&mode=3&refSoft=1&versions=55023,55024,55025,55026,55027,55061 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&mode=3&refSoft=1&versions=55023,55024,55025,55026,55027,55061 Mitigation For more information, please visit Rockwell Automations SD1776 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html Relevant CWE: CWE-354 Improper Validation of Integrity Check Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-9307 A sensitive information disclosure security issue exists within the affected CompactLogix controllers. The controller's web server exposes CIP Connection IDs on the diagnostics webpage, which are accessible to any unauthenticated user on the network. This information can be leveraged by an attacker to construct malicious packets, leading to Denial-of-Service. View CVE Details Affected Products Rockwell Automation CompactLogix Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370 L1: <V38.011, Rockwell Automation CompactLogix 5370 L2: <V38.011, Rockwell Automation CompactLogix 5370 L3: <V38.011 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users update to V38.011 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&mode=3&refSoft=1&versions=55023,55024,55025,55026,55027,55061 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&mode=3&refSoft=1&versions=55023,55024,55025,55026,55027,55061 Mitigation For more information, please visit Rockwell Automations SD1776 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html Relevant CWE: CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N 4.0 6.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Tyler Lentz of Idaho National Laboratory reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation Security Advisory SD1776 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48907 Widget Factory Joomla Content Editor Improper Access Control Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48907 Widget Factory Joomla Content Editor Improper Access Control Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20262 Cisco Catalyst SD-WAN Manager Directory or Path Traversal Vulnerability CVE-2026-54420 LiteSpeed cPanel Plugin UNIX Symbolic Link (Symlink) Following Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20262 Cisco Catalyst SD-WAN Manager Directory or Path Traversal Vulnerability CVE-2026-54420 LiteSpeed cPanel Plugin UNIX Symbolic Link (Symlink) Following Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-35273 Oracle PeopleSoft Enterprise PeopleTools Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-35273 Oracle PeopleSoft Enterprise PeopleTools Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-10520 Ivanti Sentry OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-10520 Ivanti Sentry OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Yarbo Android/iOS Mobile Application and Cloud Infrastructure

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain hard-coded credentials, gain access to telemetry data, and potentially send operational commands to the robot fleet. The following versions of Yarbo Android/iOS Mobile Application and Cloud Infrastructure are affected: Yarbo Android/IOS mobile application Cloud MQTT infrastructure vers:all/* CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain hard-coded credentials, gain access to telemetry data, and potentially send operational commands to the robot fleet. The following versions of Yarbo Android/iOS Mobile Application and Cloud Infrastructure are affected: Yarbo Android/IOS mobile application Cloud MQTT infrastructure vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Yarbo Yarbo Android/iOS Mobile Application and Cloud Infrastructure Use of Hard-coded Credentials, Missing Authorization Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-10557 The Yarbo Android and iOS applications contain hard-coded MQTT broker credentials that are identical for all users and all devices. These credentials are embedded in the application binary and are readily extractable via APK decompilation. The credentials provide access to cloud MQTT brokers carrying real-time telemetry for the entire global Yarbo robot fleet. They allow both wildcard subscription to all robot telemetry topics and publishing to any robot's command topic using only the robot's serial number.. View CVE Details Affected Products Yarbo Android/iOS Mobile Application and Cloud Infrastructure Vendor: Yarbo Product Version: Yarbo Yarbo Android/IOS mobile application: <v3.17.4, Yarbo Cloud MQTT infrastructure: vers:all/* Product Status: known_affected Remediations Mitigation Yarbo recommends users update the Yarbo mobile app to 3.17.4 or later. Server-side broker authorization will be enforced automatically upon deployment of the May 2026 update. No user action is required. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-7368 The Yarbo cloud does not enforce per-device or per-user authorization. Any client possessing valid credentials, whether the shared hard-coded credentials or legitimate per-user credentials, can subscribe to wildcard topics covering all robots globally, and can publish to any robot's command topic using only the robot's serial number (disclosed in the telemetry stream). Even after removal of hard-coded credentials from the app, a single compromised credential could still provide fleet-wide access without per-device access controls. View CVE Details Affected Products Yarbo Android/iOS Mobile Application and Cloud Infrastructure Vendor: Yarbo Product Version: Yarbo Yarbo Android/IOS mobile application: <v3.17.4, Yarbo Cloud MQTT infrastructure: vers:all/* Product Status: known_affected Remediations Mitigation Yarbo recommends users update the Yarbo mobile app to 3.17.4 or later. Server-side broker authorization will be enforced automatically upon deployment of the May 2026 update. No user action is required. Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N 4.0 8.6 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Markus Lassfolk of Truesec reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-11 Date Revision Summary 2026-06-11 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots