[
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-07",
        "title": "Hubbell Aclara Metrum Cellular Web Interface",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device.</strong></p>\n<p>The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected:</p>\n<ul>\n<li>Aclara Metrum Cellular Web Interface</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Hubbell</td>\n<td>Hubbell Aclara Metrum Cellular Web Interface</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>United States</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-1840</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Aclara Metrum Cellular Web Interface is vulnerable to unauthorized access due to the absence of authentication controls on critical system functions. This weakness exposes essential configuration settings, allowing attackers to alter operational parameters and trigger system restarts without restriction. Such unauthorized changes can disrupt normal functionality and, if performed repeatedly, may lead to a loss of communications to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-1840\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hubbell Aclara Metrum Cellular Web Interface</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hubbell</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Hubbell Aclara Metrum Cellular Web Interface: &lt;v2.1.0.105</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Hubbell encourages users to update their firmware to v2.1.0.105 in order to minimize network exposure and ensure that devices are not accessible from the Internet. Users can download version 2.1.0.105 from: <a href=\"https://aclara.my.site.com/AclaraConnect/s/\">https://aclara.my.site.com/AclaraConnect/s/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abhirup Konwar reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-23</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-23</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-03",
        "title": "Siemens Products using OpenSSL",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens Products using OpenSSL are affected:</p>\n<ul>\n<li>AI Lightweight Inference Server vers:all/* (CVE-2025-15467)</li>\n<li>Connector for Azure vers:intdot/&lt;1.8.0 (CVE-2025-15467)</li>\n<li>Databus vers:intdot/&lt;3.3.2 (CVE-2025-15467)</li>\n<li>HiMed Cockpit vers:all/* (CVE-2025-15467)</li>\n<li>RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9403 (6GK5998-3GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M804PB (6GK5804-0AP00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M812-1 ADSL-Router family vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M816-1 ADSL-Router family vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-2 (6GK5874-2AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-3 (6GK5874-3AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-3 (6GK5876-3AA02-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (6GK5876-4AA10-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC622-2C (6GK5622-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC626-2C (6GK5626-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC632-2C (6GK5632-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC636-2C (6GK5636-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC642-2C (6GK5642-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC646-2C (6GK5646-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC316-8 (6GK5324-8TS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC324-4 (6GK5328-4TS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC332 (6GK5332-0GA00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC416-8 (6GK5424-8TR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC424-4 (6GK5428-4TR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC432 (6GK5432-0GR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-2RR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-3RR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>Shopfloor IT Suite vers:all/* (CVE-2025-15467)</li>\n<li>SIDIS Prime vers:intdot/&gt;=4.0.700 (CVE-2025-15467)</li>\n<li>Siemens OPC UA Modelling Editor (SiOME) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC Comfort/Mobile RT vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC HMI Basic Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC HMI Comfort Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC HMI Mobile Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC IOT2050 (6ES7647-0BA00-1YA2) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC BX-21A vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC MD-57A vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC ORCLA vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC PDM V9.3 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA00) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA10) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA20) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA30) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA10) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA20) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA30) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC STEP 7 V5 vers:intdot/&lt;5.7.4 (CVE-2025-15467)</li>\n<li>SIMATIC Target vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.19 vers:intdot/&lt;3.19.024 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.20 vers:intdot/&lt;3.20.012 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.21 vers:intdot/&lt;3.21.02 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC Runtime Advanced V17 vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC Unified Sequence vers:intdot/&lt;21 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V7.5 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V8.0 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V8.1 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOTION OACAMGEN (6AU1820-3EA20-0AB0) vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.1 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.2 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.3 vers:all/* (CVE-2025-15467)</li>\n<li>SINAMICS G200 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS G220 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S200 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S210 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S220 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINEC INS vers:intdot/&lt;1.0.2.5 (CVE-2025-15467)</li>\n<li>SINEC NMS vers:all/* (CVE-2025-15467)</li>\n<li>SINEC Security Monitor vers:all/* (CVE-2025-15467)</li>\n<li>SINUMERIK Access MyMachine /OPC UA vers:all/* (CVE-2025-15467)</li>\n<li>SIPLANT vers:all/* (CVE-2025-15467)</li>\n<li>SITRANS ASM IQ vers:all/* (CVE-2025-15467)</li>\n<li>SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ) vers:all/* (CVE-2025-15467)</li>\n<li>User Management Component (UMC) vers:intdot/&lt;2.15.3.0 (CVE-2025-15467)</li>\n<li>Visual Inspection Cockpit vers:all/* (CVE-2025-15467)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Siemens</td>\n<td>Siemens Products using OpenSSL</td>\n<td>Out-of-bounds Write</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-15467</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Issue summary: Parsing CMS AuthEnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow. Impact summary: A stack buffer overflow may lead to a crash, causing Denial of Service, or potentially remote code execution. When parsing CMS AuthEnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before any authentication or tag verification occurs. Applications and services that parse untrusted CMS or PKCS#7 content using AEAD ciphers (e.g., S/MIME AuthEnvelopedData with AES-GCM) are vulnerable. Because the overflow occurs prior to authentication, no valid key material is required to trigger it. While exploitability to remote code execution depends on platform and toolchain mitigations, the stack-based write primitive represents a severe risk. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-15467\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Products using OpenSSL</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AI Lightweight Inference Server, Connector for Azure, Databus, HiMed Cockpit, RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE LPE9403 (6GK5998-3GS00-2AC2), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router family, SCALANCE M816-1 ADSL-Router family, SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SCALANCE XC316-8 (6GK5324-8TS00-2AC2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2), SCALANCE XC332 (6GK5332-0GA00-2AC2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2), SCALANCE XC432 (6GK5432-0GR00-2AC2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3), SCALANCE XR302-32 (6GK5334-5TS00-3AR3), SCALANCE XR302-32 (6GK5334-5TS00-4AR3), SCALANCE XR322-12 (6GK5334-3TS00-2AR3), SCALANCE XR322-12 (6GK5334-3TS00-3AR3), SCALANCE XR322-12 (6GK5334-3TS00-4AR3), SCALANCE XR326-8 (6GK5334-2TS00-2AR3), SCALANCE XR326-8 (6GK5334-2TS00-3AR3), SCALANCE XR326-8 (6GK5334-2TS00-4AR3), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3), SCALANCE XR502-32 (6GK5534-5TR00-2AR3), SCALANCE XR502-32 (6GK5534-5TR00-3AR3), SCALANCE XR502-32 (6GK5534-5TR00-4AR3), SCALANCE XR522-12 (6GK5534-3TR00-2AR3), SCALANCE XR522-12 (6GK5534-3TR00-3AR3), SCALANCE XR522-12 (6GK5534-3TR00-4AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2RR3), SCALANCE XR524-8WG (6GK5532-2SR00-3AR3), SCALANCE XR524-8WG (6GK5532-2SR00-3RR3), SCALANCE XR526-8 (6GK5534-2TR00-2AR3), SCALANCE XR526-8 (6GK5534-2TR00-3AR3), SCALANCE XR526-8 (6GK5534-2TR00-4AR3), Shopfloor IT Suite, SIDIS Prime, Siemens OPC UA Modelling Editor (SiOME), SIMATIC Comfort/Mobile RT, SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8), SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8), SIMATIC HMI Basic Panels, SIMATIC HMI Comfort Panels, SIMATIC HMI Mobile Panels, SIMATIC IOT2050 (6ES7647-0BA00-1YA2), SIMATIC IPC BX-21A, SIMATIC IPC MD-57A, SIMATIC IPC ORCLA, SIMATIC PDM V9.3, SIMATIC RTLS Locating Manager (6GT2780-0DA00), SIMATIC RTLS Locating Manager (6GT2780-0DA10), SIMATIC RTLS Locating Manager (6GT2780-0DA20), SIMATIC RTLS Locating Manager (6GT2780-0DA30), SIMATIC RTLS Locating Manager (6GT2780-1EA10), SIMATIC RTLS Locating Manager (6GT2780-1EA20), SIMATIC RTLS Locating Manager (6GT2780-1EA30), SIMATIC STEP 7 V5, SIMATIC Target, SIMATIC WinCC OA V3.19, SIMATIC WinCC OA V3.20, SIMATIC WinCC OA V3.21, SIMATIC WinCC Runtime Advanced V17, SIMATIC WinCC Unified Sequence, SIMATIC WinCC V7.5, SIMATIC WinCC V8.0, SIMATIC WinCC V8.1, SIMOTION OACAMGEN (6AU1820-3EA20-0AB0), SIMOVE Fleetmanager V3.1, SIMOVE Fleetmanager V3.2, SIMOVE Fleetmanager V3.3, SINAMICS G200, SINAMICS G220, SINAMICS S200, SINAMICS S210, SINAMICS S220, SINEC INS, SINEC NMS, SINEC Security Monitor, SINUMERIK Access MyMachine /OPC UA, SIPLANT, SITRANS ASM IQ, SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ), User Management Component (UMC), Visual Inspection Cockpit</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As a defense-in-depth measure, organizations may review whether affected systems are exposed to untrusted CMS/PKCS#7 content from external sources.</p>\n<p><strong>Mitigation</strong><br>Do not accept files from untrusted and unvalidated sources in the affected applications</p>\n<p><strong>Mitigation</strong><br>Restrict the port at the host with the DeviceConnectionProxy to secure destinations</p>\n<p><strong>Mitigation</strong><br>Securing the connected email server as follows: \u2022 Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. \u2022 Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). \u2022 Ensure strong authentication to access the email server. \u2022 Keep the email server software and underlying operating system up to date with the latest security patches.</p>\n<p><strong>Mitigation</strong><br>Securing the connected email server as follows: \u2022 Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. \u2022 Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). \u2022 Ensure strong authentication to access the email server. \u2022 Keep the email server software and underlying operating system up to date with the latest security patches.</p>\n<p><strong>Mitigation</strong><br>The hardening instructions mentioned in the products security concept should be followed</p>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>None available</strong><br>Currently no fix is available</p>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 5 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109999722/\">https://support.industry.siemens.com/cs/ww/en/view/109999722/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V1.8.0 or later version<br><a href=\"https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html\">https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17 Update 9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109800912/\">https://support.industry.siemens.com/cs/ww/en/view/109800912/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17.9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109825750/\">https://support.industry.siemens.com/cs/ww/en/view/109825750/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17 Update 9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109825750/\">https://support.industry.siemens.com/cs/ww/en/view/109825750/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2.15.3.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000730/\">https://support.industry.siemens.com/cs/ww/en/view/110000730/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V21 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996963/\">https://support.industry.siemens.com/cs/ww/en/view/109996963/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.19 P024 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000400/\">https://support.industry.siemens.com/cs/ww/en/view/110000400/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.20 P012 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000657/\">https://support.industry.siemens.com/cs/ww/en/view/110000657/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.21 P02 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000985/\">https://support.industry.siemens.com/cs/ww/en/view/110000985/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.3.2 or later version<br><a href=\"https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html\">https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html</a></p>\n<p><strong>Vendor fix</strong><br>Update to V5.7 SP4 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109991080/\">https://support.industry.siemens.com/cs/ww/en/view/109991080/</a></p>\n<p><strong>Vendor fix</strong><br>Contact customer support siplant-support.de@siemens.com</p>\n<p><strong>Vendor fix</strong><br>Contact customer support</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-434797 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-434797 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/23/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Four Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/23/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added four new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation. &nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-67038\" target=\"_blank\">CVE-2025-67038</a> Lantronix EDS5000 Code Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34908\" target=\"_blank\">CVE-2026-34908</a> Ubiquiti UniFi OS Improper Access Control Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34909\" target=\"_blank\">CVE-2026-34909</a> Ubiquiti UniFi OS Path Traversal Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34910\" target=\"_blank\">CVE-2026-34910</a> Ubiquiti UniFi OS Improper Input Validation Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-01",
        "title": "Siemens WinCC Certificate Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens WinCC Certificate Manager are affected:</p>\n<ul>\n<li>SIMATIC WinCC Unified PC Runtime V16 vers:all/*&nbsp;</li>\n<li>SIMATIC WinCC Unified PC Runtime V17 vers:all/*&nbsp;</li>\n<li>SIMATIC WinCC Unified PC Runtime V18 vers:all/*&nbsp;</li>\n<li>SIMATIC WinCC Unified PC Runtime V19 vers:all/*&nbsp;</li>\n<li>SIMATIC WinCC Unified PC Runtime V20 vers:all/*&nbsp;</li>\n<li>SIMATIC WinCC Unified PC Runtime V21 vers:intdot/&lt;21.0.2</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.1</td>\n<td>Siemens</td>\n<td>Siemens WinCC Certificate Manager</td>\n<td>Cleartext Storage in a File or on Disk</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-24349</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Insufficient protection of key material in WinCC Certificate Manager that could allow an attacker to extract sensitive information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-24349\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens WinCC Certificate Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SIMATIC WinCC Unified PC Runtime V16, SIMATIC WinCC Unified PC Runtime V17, SIMATIC WinCC Unified PC Runtime V18, SIMATIC WinCC Unified PC Runtime V19, SIMATIC WinCC Unified PC Runtime V20, SIMATIC WinCC Unified PC Runtime V21</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product.</p>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>Vendor fix</strong><br>Update to V21 Update 2 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109991140/\">https://support.industry.siemens.com/cs/ww/en/view/109991140/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/313.html\">CWE-313 Cleartext Storage in a File or on Disk</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-063511 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-063511 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-05",
        "title": "ABB Freelance Security Lock",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions.</strong></p>\n<p>The following versions of ABB Freelance Security Lock are affected:</p>\n<ul>\n<li>ABB System Version (&lt;=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.6</td>\n<td>ABB</td>\n<td>ABB Freelance Security Lock</td>\n<td>Authentication Bypass by Primary Weakness</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7064</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker is able to attack Freelance user management when Security Lock is enabled. The precondition is that the attacker bypasses Freelance Operations which blocks access to the Windows operating system. This bypass can be achieved via undocumented or special key combinations available on modern keyboards. These combinations may allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7064\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Freelance Security Lock</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB ABB System Version (&lt;=Freelance 2013) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch), CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json).<br><a href=\"https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch\">https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch)&nbsp;</p>\n<p>CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json).<br><a href=\"https://psirt.abb.com/csaf/2026/7paa020361.json\">https://psirt.abb.com/csaf/2026/7paa020361.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/305.html\">CWE-305 Authentication Bypass by Primary Weakness</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Gergely Regweld Szini reported this vulnerability to ABB</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-10</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial Republication of ABB PSIRT 7PAA020361</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-02",
        "title": "Siemens SIPROTEC 5 Using DIGSI5 Protocol",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86 are advised to upgrade to version 10.00 or later, while the remaining models should upgrade to version 9.90 or later. These versions introduce an allow-list feature that restricts arbitrary file uploads and reduces the risk associated with this vulnerability. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens SIPROTEC 5 Using DIGSI5 Protocol are affected:</p>\n<ul>\n<li>SIPROTEC 5 6MD84 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD86 (CP200) vers:all/*</li>\n<li>SIPROTEC 5 6MD86 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 6MD89 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 6MU85 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 7KE85 (CP200) vers:all/*</li>\n<li>SIPROTEC 5 7KE85 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 7SA82 (CP100) vers:all/*</li>\n<li>SIPROTEC 5 7SA82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SA86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ81 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ81 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SL86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SS85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SS85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SX82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SX85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SY82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UM85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VE85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VK87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VK87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VU85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 Compact 7SX800 (CP050) vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>Siemens</td>\n<td>Siemens SIPROTEC 5 Using DIGSI5 Protocol</td>\n<td>Unrestricted Upload of File with Dangerous Type</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40808</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application allows authenticated users to upload arbitrary files using DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, that could cause denial of service condition and potentially lead to code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40808\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SIPROTEC 5 Using DIGSI5 Protocol</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP200), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP200), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5 6MU85 (CP300), SIPROTEC 5 7KE85 (CP200), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA82 (CP100), SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SA86 (CP200), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP200), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD82 (CP100), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SD86 (CP200), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP200), SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ81 (CP100), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP100), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5 7SJ85 (CP200), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP200), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK82 (CP100), SIPROTEC 5 7SK82 (CP150), SIPROTEC 5 7SK85 (CP200), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL82 (CP100), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SL86 (CP200), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87 (CP200), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP200), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP200), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT82 (CP100), SIPROTEC 5 7UT82 (CP150), SIPROTEC 5 7UT85 (CP200), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP200), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP200), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP200), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300), SIPROTEC 5 Compact 7SX800 (CP050)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Users are advised to upgrade to V9.90 or later, which introduces an allow-list feature that restricts arbitrary file uploads</p>\n<p><strong>Mitigation</strong><br>Apply password protection to all DIGSI connections to ensure secure communication</p>\n<p><strong>Mitigation</strong><br>For DIGSI access provision your own certificates signed by your customer PKI as described in https://support.industry.siemens.com/cs/document/109768375</p>\n<p><strong>Mitigation</strong><br>For the available devices [CP050, CP100, CP150 and CP300], activate role-based access control (RBAC) in the device (supported in SIPROTEC 5 firmware versions V7.80 and higher)</p>\n<p><strong>Mitigation</strong><br>Users are advised to upgrade to V10.00 or later, which introduces an allow-list feature that restricts arbitrary file uploads</p>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>None available</strong><br>Currently no fix is available</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-139483 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-139483 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-04",
        "title": "Siemens SINEC INS",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens SINEC INS are affected:</p>\n<ul>\n<li>SINEC INS vers:intdot/&lt;1.0.2.6&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Siemens</td>\n<td>Siemens SINEC INS</td>\n<td>Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Path Traversal: '/dir/../filename', Execution with Unnecessary Privileges, Use of a One-Way Hash with a Predictable Salt</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46746</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins).</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46746\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC INS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC INS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 6 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110002283/\">https://support.industry.siemens.com/cs/ww/en/view/110002283/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46747</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46747\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC INS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC INS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 6 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110002283/\">https://support.industry.siemens.com/cs/ww/en/view/110002283/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/26.html\">CWE-26 Path Traversal: '/dir/../filename'</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46748</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46748\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC INS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC INS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 6 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110002283/\">https://support.industry.siemens.com/cs/ww/en/view/110002283/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/250.html\">CWE-250 Execution with Unnecessary Privileges</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46749</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46749\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SINEC INS</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SINEC INS</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 6 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110002283/\">https://support.industry.siemens.com/cs/ww/en/view/110002283/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/760.html\">CWE-760 Use of a One-Way Hash with a Predictable Salt</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-860189 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-860189 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-06",
        "title": "Impact of Linux Kernel vulnerabilities on B&R products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>B&amp;R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this advisory, B&amp;R had no evidence of active exploitation targeting B&amp;R products.</strong></p>\n<p>The following versions of Impact of Linux Kernel vulnerabilities on B&amp;R products are affected:</p>\n<ul>\n<li>Linux for B&amp;R &lt;=12&nbsp;</li>\n<li>APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602</li>\n<li>X20EDS410 /all&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>B&amp;R Industrial Automation GmbH</td>\n<td>Impact of Linux Kernel vulnerabilities on B&amp;R products</td>\n<td>Incorrect Resource Transfer Between Spheres, Write-what-where Condition, Improper Privilege Management, Out-of-bounds Write, Multiple Releases of Same Resource or Handle</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31431</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: crypto: algif_aead - Revert to operating out-of-place This mostly reverts commit 72548b093ee3 except for the copying of the associated data. There is no benefit in operating in-place in algif_aead since the source and destination come from different mappings. Get rid of all the complexity added for in-place operation and just copy the AD directly.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31431\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/669.html\">CWE-669 Incorrect Resource Transfer Between Spheres</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:H/RC:C\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:H/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-43284</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: xfrm: esp: avoid in-place decrypt on shared skb frags MSG_SPLICE_PAGES can attach pages from a pipe directly to an skb. TCP marks such skbs with SKBFL_SHARED_FRAG after skb_splice_from_iter(), so later paths that may modify packet data can first make a private copy. The IPv4/IPv6 datagram append paths did not set this flag when splicing pages into UDP skbs. That leaves an ESP-in-UDP packet made from shared pipe pages looking like an ordinary uncloned nonlinear skb. ESP input then takes the no-COW fast path for uncloned skbs without a frag_list and decrypts in place over data that is not owned privately by the skb. Mark IPv4/IPv6 datagram splice frags with SKBFL_SHARED_FRAG, matching TCP. Also make ESP input fall back to skb_cow_data() when the flag is present, so ESP does not decrypt external-ly backed frags in place. Private nonlinear skb frags still use the existing fast path. This intentionally does not change ESP output. In esp_output_head(), the path that appends the ESP trailer to existing skb tailroom without calling skb_cow_data() is not reachable for nonlinear skbs: skb_tailroom() returns zero when skb-&gt;data_len is nonzero, while ESP tailen is positive. Thus ESP output will either use the separate destination-frag path or fall back to skb_cow_data().</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-43284\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/123.html\">CWE-123 Write-what-where Condition</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46333</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: ptrace: slightly saner 'get_dumpable()' logic The 'dumpability' of a task is fundamentally about the memory image of the task - the concept comes from whether it can core dump or not - and makes no sense when you don't have an associated mm. And almost all users do in fact use it only for the case where the task has a mm pointer. But we have one odd special case: ptrace_may_access() uses 'dumpable' to check various other things entirely independently of the MM (typically explicitly using flags like PTRACE_MODE_READ_FSCREDS). Including for threads that no longer have a VM (and maybe never did, like most kernel threads). It's not what this flag was designed for, but it is what it is. The ptrace code does check that the uid/gid matches, so you do have to be uid-0 to see kernel thread details, but this means that the traditional \"drop capabilities\" model doesn't make any difference for this all. Make it all make a *bit* more sense by saying that if you don't have a MM pointer, we'll use a cached \"last dumpability\" flag if the thread ever had a MM (it will be zero for kernel threads since it is never set), and require a proper CAP_SYS_PTRACE capability to override.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46333\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/269.html\">CWE-269 Improper Privilege Management</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46300</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: net: skbuff: preserve shared-frag marker during coalescing skb_try_coalesce() can attach paged frags from @from to @to. If @from has SKBFL_SHARED_FRAG set, the resulting @to skb can contain the same externally-owned or page-cache-backed frags, but the shared-frag marker is currently lost. That breaks the invariant relied on by later in-place writers. In particular, ESP input checks skb_has_shared_frag() before deciding whether an uncloned nonlinear skb can skip skb_cow_data(). If TCP receive coalescing has moved shared frags into an unmarked skb, ESP can see skb_has_shared_frag() as false and decrypt in place over page-cache backed frags. Propagate SKBFL_SHARED_FRAG when skb_try_coalesce() transfers paged frags. The tailroom copy path does not need the marker because it copies bytes into @to's linear data rather than transferring frag descriptors..</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46300\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-43494</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: net/rds: reset op_nents when zerocopy page pin fails When iov_iter_get_pages2() fails in rds_message_zcopy_from_user(), the pinned pages are released with put_page(), and rm-&gt;data.op_mmp_znotifier is cleared. But we fail to properly clear rm-&gt;data.op_nents. Later when rds_message_purge() is called from rds_sendmsg() the cleanup loop iterates over the incorrectly non zero number of op_nents and frees them again. Fix this by properly resetting op_nents when it should be in rds_message_zcopy_from_user().</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-43494\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1341.html\">CWE-1341 Multiple Releases of Same Resource or Handle</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerabilities? - The vulnerabilities are caused by a vulnerable Linux Kernel component. What might an attacker use the vulnerability to do? - An authenticated attacker with low privileges may elevate privileges to root. Could the vulnerabilities be exploited remotely? - Yes, an attacker with privileges to login in a vulnerable system node could exploit these vulnerabilities. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had B&amp;R received any reports that these vulnerabilities were being exploited? - B&amp;R is aware of reports indicating that these vulnerabilities had been exploited at the time this security advisory was originally issued; however, no exploitation has been observed in B&amp;R products.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA26P010 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-11</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Updating the CWE classification for CVE-2026-43494.</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT SA26P010 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/18/cisa-urges-hardening-fortinet-devices-after-reports-credential-exposure",
        "title": "CISA Urges Hardening Fortinet Devices After Reports of Credential Exposure",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/18/cisa-urges-hardening-fortinet-devices-after-reports-credential-exposure",
        "summary": "<p><strong>Update June 22, 2026:</strong><br><em>CISA has updated this Alert to incorporate the link to Fortinet\u2019s recent guidance on this activity.&nbsp;</em></p>\n<p>CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. &nbsp;</p>\n<p>To defend against this malicious cyber activity, CISA urges impacted Fortinet customers with FortiGate appliances and associated secure sockets layer (SSL) VPN gateways to immediately:</p>\n<ol>\n<li><strong>Terminate sessions and reset credentials.</strong> Terminate all active SSL VPN and administrative sessions. Reset all Fortinet VPN and administrative passwords, especially on internet-facing systems, and enforce strong password policies.</li>\n<li><strong>Ensure secure credential storage.</strong> Confirm your organization\u2019s use of the Password-Based Key Derivation Function 2 (PBKDF2) algorithm to store administrator credentials and remove weaker legacy hashes per Fortinet\u2019s guidance (see, <a href=\"https://community.fortinet.com/fortigate-3/technical-tip-enforcing-pbkdf2-as-hash-function-for-administrator-accounts-in-fortios-v7-2-11-and-later-220652\" target=\"_blank\">Fortinet's Technical Tip: Enforcing PBKDF2 as hash function for administrator accounts in FortiOS v7.2.11 and later</a>). &nbsp;</li>\n<li><strong>Review logs.</strong> Review firewall, VPN, authentication, and domain controller logs for lateral movement, unusual access, suspicious accounts, or unauthorized configuration changes.</li>\n<li><strong>Enable phishing-resistant multifactor authentication (MFA).</strong> <a href=\"https://www.cisa.gov/sites/default/files/publications/fact-sheet-implementing-phishing-resistant-mfa-508c.pdf\">Require phishing-resistant MFA</a> on all remote access and administrative accounts and ensure it is enforced on all external gateways and administrative interfaces.</li>\n<li><strong>Reduce the attack surface and lock down management access.</strong> Ensure the administration of your firewall is inaccessible from the public internet; restrict Fortinet management interfaces to trusted internal networks; and remove or disable any unauthorized or unnecessary accounts.</li>\n</ol>\n<p>See the following resources to determine your organization\u2019s potential impact and find additional guidance on the credentials compromised:</p>\n<ul>\n<li>Tech Times: <a href=\"https://www.techtimes.com/articles/318599/20260618/fortinet-fortigate-credential-leak-hits-73932-firewalls-half-internet-facing-fleet.htm\" target=\"_blank\">Fortinet FortiGate Credential Leak Hits 73,932 Firewalls: Half the Internet-Facing Fleet</a> &nbsp;</li>\n<li>SOCRadar: <a href=\"https://socradar.io/blog/fortibleed-fortinet-firewalls-compromised/\" target=\"_blank\">FortiBleed: The Compromise of 80,000+ Fortinet Firewalls</a></li>\n<li>Hudson Rock: <a href=\"https://www.hudsonrock.com/blog/fortibleed-75000-fortinet-firewalls-compromised-global-enterprises-exposed-claim-your-ethical-disclosure\" target=\"_blank\">FortiBleed: 75,000 Fortinet Firewalls Compromised: Global Enterprises Exposed \u2013 Claim Your Ethical Disclosure</a></li>\n<li>Arctic Wolf: <a href=\"https://arcticwolf.com/resources/blog/active-fortibleed-campaign-impacting-fortinet-devices-across-194-countries/\" target=\"_blank\">Active FortiBleed Campaign Impacting Fortinet Devices Across 194 Countries</a></li>\n<li>Fortinet: <a href=\"https://www.fortinet.com/blog/industry-trends/attacks-at-the-speed-of-ai\" target=\"_blank\">Attacks at the Speed of AI</a></li>\n<li>Fortinet: <a href=\"https://www.fortinet.com/blog/psirt-blogs/analysis-of-reported-credential-compromise-of-fortigate-devices\" target=\"_blank\">Analysis of Reported Credential Compromise of FortiGate Devices</a></li>\n</ul>\n<h2><strong>Disclaimer</strong></h2>\n<p>The information in this report is being provided \u201cas is\u201d for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20253\" target=\"_blank\">CVE-2026-20253</a> Splunk Enterprise Missing Authentication for Critical Function Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating <a href=\"https://www.cisa.gov/news-events/directives/bod-22-01-reducing-significant-risk-known-exploited-vulnerabilities-revoked\">BOD 22-01</a>. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit for potential addition: <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-169-01",
        "title": "Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-169-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-169-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device.</strong></p>\n<p>The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected:</p>\n<ul>\n<li>Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Apollo Pharmacy</td>\n<td>Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT</td>\n<td>Cleartext Transmission of Sensitive Information, Missing Authorization</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>India</li>\n<li><strong>Company Headquarters Location: </strong>India</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50034</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50034\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Apollo Pharmacy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us.<br><a href=\"https://www.apollopharmacy.in/contact-us\">https://www.apollopharmacy.in/contact-us</a></p>\n<p><strong>Mitigation</strong><br>CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology.<br><a href=\"https://www.cisa.gov/news-events/news/understanding-bluetooth-technology\">https://www.cisa.gov/news-events/news/understanding-bluetooth-technology</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-52866</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-52866\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Apollo Pharmacy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us.<br><a href=\"https://www.apollopharmacy.in/contact-us\">https://www.apollopharmacy.in/contact-us</a></p>\n<p><strong>Mitigation</strong><br>CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology.<br><a href=\"https://www.cisa.gov/news-events/news/understanding-bluetooth-technology\">https://www.cisa.gov/news-events/news/understanding-bluetooth-technology</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-02",
        "title": "AzeoTech DAQFactory",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution.</strong></p>\n<p>The following versions of AzeoTech DAQFactory are affected:</p>\n<ul>\n<li>DAQFactory &lt;=21.1 (CVE-2026-12390)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>AzeoTech</td>\n<td>AzeoTech DAQFactory</td>\n<td>Access of Resource Using Incompatible Type ('Type Confusion')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12390</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In AzeoTech DAQFactory versions 21.1 and prior, a Type Confusion vulnerability can be exploited by an attacker using specially crafted .ctl files which can result in code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12390\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AzeoTech DAQFactory</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AzeoTech</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AzeoTech DAQFactory: &lt;=21.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Users are discouraged from using documents from unknown/untrusted sources.</p>\n<p><strong>Mitigation</strong><br>Users are encouraged to store .ctl files in a folder only writeable by admin-level users.</p>\n<p><strong>Mitigation</strong><br>Users are encouraged to operate in \"Safe Mode\" when loading documents that have been out of their control.</p>\n<p><strong>Mitigation</strong><br>Users are encouraged to apply a document editing password to their documents.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/843.html\">CWE-843 Access of Resource Using Incompatible Type ('Type Confusion')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rocco Calvi (@TecR0c) of TecSecurity reported this vulnerability to CISA</li>\n<li>rgod of TrendAI Zero Day Initiative reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-04",
        "title": "Schneider Electric EasyLogic T150 and Saitel DP",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files</strong></p>\n<p>The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected:</p>\n<ul>\n<li>Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller (All versions) vers:semver/&lt;=11.06.31 (CVE-2026-6865)</li>\n<li>Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller (All versions) vers:semver/&lt;=11.06.36 (CVE-2026-6865)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.1</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EasyLogic T150 and Saitel DP</td>\n<td>Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-6865</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\"Path Traversal\") vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-6865\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EasyLogic T150 and Saitel DP</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller (All versions): vers:semver/&lt;=11.06.31, Schneider Electric Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller (All versions): vers:semver/&lt;=11.06.36</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller Firmware (vers:semver/&lt;=11.06.31) installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller includes a fix for this vulnerability and is available for download here:</p>\n<p><strong>Mitigation</strong><br>Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes</p>\n<p><strong>Mitigation</strong><br>Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller Firmware (vers:semver/&lt;=11.06.36) installed on Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller (All versions): Version 11.06.37 of Saitel DP Remote Terminal Unit &amp; Controller includes a fix for this vulnerability and is available for download here:</p>\n<p><strong>Mitigation</strong><br>Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes</p>\n<p><strong>Mitigation</strong><br>All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure strict credential controls, even for low privilege users.</p>\n<p><strong>Mitigation</strong><br>Ensure isolation and credentials are in place, as per the product's security recommendations.</p>\n<p><strong>Mitigation</strong><br>The following product versions have been fixed: Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-6865</p>\n<p><strong>Mitigation</strong><br>Firmware Version 11.06.37 installed on Saitel DP Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-6865</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-132-03.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-132-03.pdf</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version.<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-132-03.json\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-132-03.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-12</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-132-03</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-01",
        "title": "AVer PTC cameras",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow arbitrary code execution.</strong></p>\n<p>The following versions of AVer PTC cameras are affected:</p>\n<ul>\n<li>PTC500S vers:all/* (CVE-2026-40624)</li>\n<li>PTC115 vers:all/* (CVE-2026-40624)</li>\n<li>PTC500+ vers:all/* (CVE-2026-40624)</li>\n<li>PTC115+ vers:all/* (CVE-2026-40624)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>AVer</td>\n<td>AVer PTC cameras</td>\n<td>Files or Directories Accessible to External Parties</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Government Services and Facilities, Commercial Facilities, Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40624</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper input validation in AVer PTC500S, PTC115, PTC500+, and PTC115+ cameras may allow a remote, unauthenticated attacker to achieve arbitrary code execution via a specially crafted web request.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40624\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVer PTC cameras</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVer</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVer PTC500S: vers:all/*, AVer PTC115: vers:all/*, AVer PTC500+: vers:all/*, AVer PTC115+: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>AVer has provided a firmware fix to address this vulnerability; users can find it at the following location: (https://presentation.aver.com/DownloadFile.aspx?n=6617|1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&amp;t=ServiceDownload).<br><a href=\"https://presentation.aver.com/DownloadFile.aspx?n=6617%7C1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&amp;t=ServiceDownload\">https://presentation.aver.com/DownloadFile.aspx?n=6617%7C1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&amp;t=ServiceDownload</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/552.html\">CWE-552 Files or Directories Accessible to External Parties</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>fj016 reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-03",
        "title": "Rockwell Automation FactoryTalk Historian Site Edition",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system.</strong></p>\n<p>The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected:</p>\n<ul>\n<li>FactoryTalk Historian SE 11 (CVE-2025-13036)</li>\n<li>FactoryTalk Historian SE &lt;=11.00 (CVE-2025-44019)</li>\n<li>FactoryTalk Historian SE &lt;=11.00 (CVE-2025-36539)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.7</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation FactoryTalk Historian Site Edition</td>\n<td>Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Uncaught Exception</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-13036</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-13036\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk Historian Site Edition</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk Historian SE: 11</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends the following: Mitigations and Workarounds for CVE-2025-13036: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and consider applying the available patch (BF32850) for their current version (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US).<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html)<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/362.html\">CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-44019</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. Depending on the timing of the crash, data present in snapshots/write cache may be lost.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-44019\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk Historian Site Edition</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk Historian SE: &lt;=11.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html)<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/248.html\">CWE-248 Uncaught Exception</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-36539</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-36539\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk Historian Site Edition</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk Historian SE: &lt;=11.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitigations and Workarounds for CVE-2025-36539 &amp; CVE-2025-44109: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and also consider the following: Monitor liveness of PI Network Manager and PI Archive Subsystem services. Set the PI Network Manager and PI Archive Subsystem services to automatically restart. Limit port 5450 access to trusted workstations and software. For a list of PI System firewall port requirements, see knowledge base article KB01162 - Firewall Port Requirements. For a starting point on PI system security best practices, see knowledge base article KB00833 - Best practices for securing your PI Server.</p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html)<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/248.html\">CWE-248 Uncaught Exception</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Security Advisory SD1773</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-07",
        "title": "Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of vulnerabilities in its PowerChute\u2122 Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could result in disruption of operations and access to system data.</strong></p>\n<p>The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products are affected:</p>\n<ul>\n<li>Easergy MiCOM C264 vers:generic/&lt;=D7.33 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P139 vers:generic/&lt;=P139.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P437 vers:generic/&lt;=P437.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P439 vers:generic/&lt;=P439.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P532 vers:generic/&lt;=P532.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P539 vers:generic/&lt;=P539.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P631 vers:generic/&lt;=P631.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P632 vers:generic/&lt;=P632.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P633 vers:generic/&lt;=P633.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P634 vers:generic/&lt;=P634.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P633 P633.680.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P634 P634.680.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P138 vers:generic/&lt;=P138.677.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P436 vers:generic/&lt;=P436.677.701 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P438 vers:generic/&lt;=P438.677.701 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P638 vers:generic/&lt;=P638.677.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM C434 vers:generic/&lt;=C434.679.700 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Automation System Gateway (EPAS-GTW) vers:intdot/&lt;=6.4.616.200.100 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Automation System User Interface (EPAS-UI) vers:intdot/&lt;=3.0.3 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Operation vers:generic/&lt;=2022_CU6 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Operation vers:generic/&lt;=2024_CU2 (CVE-2026-4827)</li>\n<li>iPMFLS vers:intdot/&lt;=64.2025.0.13 (CVE-2026-4827)</li>\n<li>PowerLogic P5 Protection Relay vers:intdot/&lt;=02.502.103 (CVE-2026-4827)</li>\n<li>PowerLogic P7 Protection and Control Platform vers:intdot/&lt;=02.002.002 (CVE-2026-4827)</li>\n<li>PowerLogic T300 vers:intdot/&lt;=2.9.4 (CVE-2026-4827)</li>\n<li>PowerLogic T500 vers:intdot/&lt;=11.08.02 (CVE-2026-4827)</li>\n<li>Saitel DP vers:intdot/&lt;=11.06.36 ()</li>\n<li>EasyLogic T150 (formerly Saitel DR) vers:intdot/&lt;=11.06.30 ()</li>\n<li>Easergy MiCOM C264 D7.34 ()</li>\n<li>Easergy C5 vers:intdot/&lt;=1.1.17 (CVE-2026-4827)</li>\n<li>Easergy C5 1.1.18 ()</li>\n<li>Easergy MiCOM P139 version P139.678.700 ()</li>\n<li>Easergy MiCOM P439 P439.678.700 ()</li>\n<li>Easergy MiCOM P539 P539.678.700 ()</li>\n<li>Easergy MiCOM P632 P632.678.700 ()</li>\n<li>Easergy MiCOM P633 P633.680.701 ()</li>\n<li>Easergy MiCOM P634 P634.680.701 ()</li>\n<li>Easergy MiCOM P633 P633.678.700 ()</li>\n<li>Easergy MiCOM P138 P138.677.701 ()</li>\n<li>Easergy MiCOM C434 C434.679.700 ()</li>\n<li>Saitel DR 11.06.31 ()</li>\n<li>EcoStruxure Power Automation System Gateway (EPAS-GTW) 6.4.610.500.101 ()</li>\n<li>EcoStruxure Power Automation Automation System User Interface (EPAS-UI) 3.0.4 ()</li>\n<li>EcoStruxure Power Operation 2022_CU7 ()</li>\n<li>EcoStruxure Power Operation (EPO) 2024_CU3 ()</li>\n<li>iPMFLS 64.2025.0.14 ()</li>\n<li>PowerLogic P5 Protection Relay 02.503.101 ()</li>\n<li>PowerLogic P7 Protection and Control Platform 02.003.001 ()</li>\n<li>PowerLogic T300 2.9.5 ()</li>\n<li>PowerLogic T500 11.08.03 ()</li>\n<li>Saitel DP 11.06.37 ()</li>\n<li>Easergy MiCOM P40 Series vers:all/* (CVE-2026-4827)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products</td>\n<td>Insufficient Entropy</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-4827</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-331 Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session\u2011management protections.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-4827\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Easergy MiCOM C264 Versions D7.33 and prior, Easergy MiCOM P139 version prior to P139.678.700, Easergy MiCOM P437 version prior to P437.678.700, Easergy MiCOM P439 version prior to P439.678.700, Easergy MiCOM P532 version prior to P532.678.700, Easergy MiCOM P539 version prior to P539.678.700, Easergy MiCOM P631 version prior to P631.678.700, Easergy MiCOM P632 version prior to P632.678.700, Easergy MiCOM P633 version prior to P633.678.700, Easergy MiCOM P634 version prior to P634.678.700, Easergy MiCOM P633 version P633.680.700, Easergy MiCOM P634 version P634.680.700 , Easergy MiCOM P138 version prior to P138.677.700, Easergy MiCOM P436 version prior to P436.677.701, Easergy MiCOM P438 version prior to P438.677.701, Easergy MiCOM P638 version prior to P638.677.700, Easergy MiCOM C434 version prior to C434.679.700, EcoStruxure Power Automation System Gateway (EPAS-GTW) Version 6.4.616.200.100 and prior, EcoStruxure Power Automation System User Interface (EPAS-UI) Version 3.0.3 and prior, EcoStruxure Power Operation (EPO) 2022 CU6 and prior, EcoStruxure Power Operation (EPO) 2024 CU2 and prior, iPMFLS Version 64.2025.0.13 and prior, PowerLogic P5 Protection Relay V02.502.103 and prior, PowerLogic P7 Protection and Control Platform V02.002.002 and prior, PowerLogic T300 Version 2.9.4 and prior, PowerLogic T500 Version 11.08.02 and prior, Easergy C5 Version 1.1.17 and prior, Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L and all firmware versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required</p>\n<p><strong>Vendor fix</strong><br>Version 1.1.18 of Easergy C5 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required</p>\n<p><strong>Vendor fix</strong><br>Version P139.678.700 Easergy MiCOM P139 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P439.678.700 Easergy MiCOM P439 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P539.678.700 Easergy MiCOM P539 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P632.678.700 Easergy MiCOM P632 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P633.678.700 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P634.680.701 Easergy MiCOM P634 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P633.680.701 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P138.677.701 Easergy MiCOM P138 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version C434.679.700 Easergy MiCOM C434 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>HUe Firmware version 11.06.31 includes a fix for this vulnerability and is available for download here: . Contact Schneider Electric\u2019s Customer Care Center to download this software. A reboot is needed to complete the firmware upgrade</p>\n<p><strong>Vendor fix</strong><br>Version 6.4.610.500.101 of EPAS Gateway includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this software</p>\n<p><strong>Vendor fix</strong><br>Version 3.0.4 of EPAS-UI includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this software.</p>\n<p><strong>Vendor fix</strong><br>EPO 2022 CU 7 of EcoStruxure\u2122 Power Operation includes a fix for this vulnerability and is available for download here: \u2022 https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2022-CU7-is-Now-Available/tdp/524787 Reboot needed: yes<br><a href=\"https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787\">https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787</a></p>\n<p><strong>Vendor fix</strong><br>EPO 2024 CU 3 of EcoStruxure\u2122 Power Operation includes a fix for this vulnerability and is available for download here: \u2022 https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2024-CU3-is-HERE/td-p/534769 Reboot needed: yes<br><a href=\"https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769\">https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769</a></p>\n<p><strong>Vendor fix</strong><br>Version 64.2025.0.14 of iPMFLS includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version V02.503.101 of PowerLogic\u2122 P5 includes a fix for this vulnerability Contact Schneider Electric\u2019s Customer Care Center to download this firmware.</p>\n<p><strong>Vendor fix</strong><br>Version V02.003.001 of PowerLogic\u2122 P7 includes a fix for this vulnerability Contact Schneider Electric\u2019s Customer Care Center to download this firmware.</p>\n<p><strong>Vendor fix</strong><br>Version 2.9.5 of PowerLogic\u2122 T300 includes a fix for this vulnerability Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade</p>\n<p><strong>Vendor fix</strong><br>Version 11.08.03 of PowerLogic\u2122 T500 includes a fix for this vulnerability Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade</p>\n<p><strong>Vendor fix</strong><br>CPU866e Firmware version 11.06.37 includes a fix for this vulnerability and is available for download. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade</p>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for all future versions of the following models of the Easergy MiCOM P30: P437 P532 P631 P634 P436 P438 P638 Future versions will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. \u2022 Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions</p>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for a future version of the Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L. P_ 4_ _ _ _ _ G_ _ _ _ _ M P_ 4_ _ _ _ _ H_ _ _ _ _ M P_ 4_ _ _ _ _ L _ _ _ _ _ M P_ 4_ _ _ _ _ G_ _ _ _ _ L P_ 4_ _ _ _ _ H_ _ _ _ _ L P_ 4_ _ _ _ _ L _ _ _ _ _ L A future version will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Ensure P40 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. \u2022 Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. \u2022 Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/331.html\">CWE-331 Insufficient Entropy</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-12</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-132-02 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-06",
        "title": "Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop.</strong></p>\n<p>The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module are affected:</p>\n<ul>\n<li>Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP vers:all/* (CVE-2026-8806)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module</td>\n<td>Expected Behavior Violation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-8806</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-8806\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>No fix planned</strong><br>There are no plans to release fixed version for MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. For customers of MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP, refer to the Mitsubishi Electric security advisory \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf\", and take the actions described there.<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf</a></p>\n<p><strong>Mitigation</strong><br>For customers, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to \"13.1 IP Filter Function\" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link \"https://www.mitsubishielectric.com/fa/download/index.html.\"<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Mitigation</strong><br>For customers, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/440.html\">CWE-440 Expected Behavior Violation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric discovering this vulnerability</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric 2026-003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Initial CISA Republication of Mitsubishi Electric 2026-003 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-05",
        "title": "Mitsubishi Electric MELSEC iQ-F Series",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access.</strong></p>\n<p>The following versions of Mitsubishi Electric MELSEC iQ-F Series are affected:</p>\n<ul>\n<li>MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP &lt;=1.000 (CVE-2026-8805)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric MELSEC iQ-F Series</td>\n<td>Integer Overflow or Wraparound</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-8805</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An integer overflow or wraparound vulnerability exists in the EtherNet/IP function of MELSEC iQ-F Series EtherNet/IP module. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-8805\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSEC iQ-F Series</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP: &lt;=1.000</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.001 or later for MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP. Download the update file for the fixed version from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-002_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to \"13.1 IP Filter Function\" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link \"https://www.mitsubishielectric.com/fa/download/index.html.\"<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric 2026-002 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-18</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-18</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Initial CISA Republication of Mitsubishi Electric 2026-002 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 18 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 18 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-02",
        "title": "Rockwell Automation RSLinx",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability can lead to a denial of service, where the application will become unresponsive and will not recover on its own.</strong></p>\n<p>The following versions of RSLinx Classic Third-Party Vulnerability are affected:</p>\n<ul>\n<li>RSLinx Classic &lt;=4.50.00 (CVE-2020-13573)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>RSLinx Classic Third-Party Vulnerability</td>\n<td>Out-of-bounds Read</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2020-13573</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2020-13573\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>RSLinx Classic Third-Party Vulnerability</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation RSLinx Classic: &lt;=4.50.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends that customers using the affected software should upgrade to version 4.60.00 or later. Customers who are not able to upgrade to one of the corrected versions, should consider applying the available patch (BF31213) for their current version or applying the recommended security best practices.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1774.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1774.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-16</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Advisory SD1774</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-05",
        "title": "Rockwell Automation FLEX I/O EtherNet/IP Adapters",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access, account takeover, and cause loss of availability.</strong></p>\n<p>The following versions of Rockwell Automation FLEX I/O EtherNet/IP Adapters are affected:</p>\n<ul>\n<li>1794-AENTR V2.012 (CVE-2026-0646, CVE-2026-0647)</li>\n<li>1794-AENTRXT V2.012 (CVE-2026-0646, CVE-2026-0647)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation FLEX I/O EtherNet/IP Adapters</td>\n<td>Missing Release of Memory after Effective Lifetime, Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0646</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within the 1794-AENTR adapter due to improper memory handling of CIP protocol requests. This vulnerability can result in the adapter faulting and losing connection to its associated I/O modules, requiring a manual reset to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-0646\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FLEX I/O EtherNet/IP Adapters</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation 1794-AENTR: V2.012, Rockwell Automation 1794-AENTRXT: V2.012</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends users update to 2.013 to resolve these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For more information, please visit Rockwell Automation's SD1775 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-0647</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An improper authentication security issue exists within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device's embedded web server's availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-0647\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FLEX I/O EtherNet/IP Adapters</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation 1794-AENTR: V2.012, Rockwell Automation 1794-AENTRXT: V2.012</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends users update to 2.013 to resolve these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For more information, please visit Rockwell Automation's SD1775 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-16</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Security Advisory SD1775</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-03",
        "title": "Rockwell Automation Logix 5370 & 5570 Controllers Vulnerable To Denial of Service Via CIP",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could cause a denial-of-service condition that may result in a major nonrecoverable fault (MNRF).</strong></p>\n<p>The following versions of Rockwell Automation Logix 5370 &amp; 5570 Controllers Vulnerable To Denial of Service Via CIP are affected:</p>\n<ul>\n<li>CompactLogix 5370 &lt;=34.016 (CVE-2026-11317)</li>\n<li>Compact GuardLogix 5370 &lt;=35.015 (CVE-2026-11317)</li>\n<li>ControlLogix 5570 &lt;=35.015 (CVE-2026-11317)</li>\n<li>GuardLogix 5570 36.012 (CVE-2026-11317)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation Logix 5370 &amp; 5570 Controllers Vulnerable To Denial of Service Via CIP</td>\n<td>Improper Resource Shutdown or Release</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-11317</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial of service security issue exists in the affected product. The security issue stems from a fault occurring when a crafted CIP message is sent. Devices with less memory are more likely to be affected. This can result in a major nonrecoverable fault (MNRF). A program download is required to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-11317\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Logix 5370 &amp; 5570 Controllers Vulnerable To Denial of Service Via CIP</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation CompactLogix 5370: &lt;=34.016, Rockwell Automation Compact GuardLogix 5370: &lt;=35.015, Rockwell Automation ControlLogix 5570: &lt;=35.015, Rockwell Automation GuardLogix 5570: 36.012</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users to update to the following versions: CompactLogix 5370: Versions 34.016 and later</p>\n<p><strong>Vendor fix</strong><br>Compact GuardLogix 5370: Versions 35.015 and later</p>\n<p><strong>Vendor fix</strong><br>ControlLogix 5570: Versions 36.012 and later</p>\n<p><strong>Vendor fix</strong><br>GuardLogix 5570: Versions 37.011 and later</p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisory SD1772 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1772.html)<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1772.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1772.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/404.html\">CWE-404 Improper Resource Shutdown or Release</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-16</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Security Advisory SD1772</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-01",
        "title": "Rockwell Automation FactoryTalk Analytics PavilionX",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in an attacker executing privileged operations.</strong></p>\n<p>The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected:</p>\n<ul>\n<li>FactoryTalk Analytics PavilionX &lt;7.01 (CVE-2025-14272)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation FactoryTalk Analytics PavilionX</td>\n<td>Missing Authorization</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-14272</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue was identified in Pavilion due to improper authorization enforcement in API endpoints. This vulnerability can allow an unauthorized actor to execute privileged operations, including user/role management and other administrative actions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-14272\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk Analytics PavilionX</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk Analytics PavilionX: &lt;7.01</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update FactoryTalk Analytics PavilionX software to version 7.01 or later. The upgrade can be downloaded from the Rockwell Automation Download Center: https://www.rockwellautomation.com/en-us/support/product/product-downloads.html<br><a href=\"https://www.rockwellautomation.com/en-us/support/product/product-downloads.html\">https://www.rockwellautomation.com/en-us/support/product/product-downloads.html</a></p>\n<p><strong>Mitigation</strong><br>See Rockwell Automation's SD1777 advisory for more information: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-16</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation advisory SD1777</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48907\" target=\"_blank\">CVE-2026-48907</a> Widget Factory Joomla Content Editor Improper Access Control Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating <a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">BOD 22-01</a>. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-04",
        "title": "Rockwell Automation CompactLogix",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition.</strong></p>\n<p>The following versions of Rockwell Automation CompactLogix are affected:</p>\n<ul>\n<li>CompactLogix 5370 L1</li>\n<li>CompactLogix 5370 L2</li>\n<li>CompactLogix 5370 L3</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation CompactLogix</td>\n<td>Improper Validation of Integrity Check Value, Exposure of Sensitive System Information to an Unauthorized Control Sphere</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11694</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within 1769 CompactLogix controllers due to the missing validation of sequence numbers and source IP addresses in the CIP protocol. This allows attacker to abuse the exposed Connection ID's visible on the web interface to perform denial-of-service attacks, resulting in a minor fault.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11694\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation CompactLogix</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation CompactLogix 5370 L1: &lt;V38.011, Rockwell Automation CompactLogix 5370 L2: &lt;V38.011, Rockwell Automation CompactLogix 5370 L3: &lt;V38.011</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends users update to V38.011 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061<br><a href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061\">https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061</a></p>\n<p><strong>Mitigation</strong><br>For more information, please visit Rockwell Automations SD1776 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/354.html\">CWE-354 Improper Validation of Integrity Check Value</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9307</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A sensitive information disclosure security issue exists within the affected CompactLogix controllers. The controller's web server exposes CIP Connection IDs on the diagnostics webpage, which are accessible to any unauthenticated user on the network. This information can be leveraged by an attacker to construct malicious packets, leading to Denial-of-Service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9307\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation CompactLogix</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation CompactLogix 5370 L1: &lt;V38.011, Rockwell Automation CompactLogix 5370 L2: &lt;V38.011, Rockwell Automation CompactLogix 5370 L3: &lt;V38.011</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends users update to V38.011 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061<br><a href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061\">https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=55023,55024,55025,55026,55027,55061</a></p>\n<p><strong>Mitigation</strong><br>For more information, please visit Rockwell Automations SD1776 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/497.html\">CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Tyler Lentz of Idaho National Laboratory reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-16</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-16</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Security Advisory SD1776</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 16 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 16 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/15/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/15/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20262\" target=\"_blank\">CVE-2026-20262</a> Cisco Catalyst SD-WAN Manager Directory or Path Traversal Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-54420\" target=\"_blank\">CVE-2026-54420</a> LiteSpeed cPanel Plugin UNIX Symbolic Link (Symlink) Following Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating <a href=\"https://www.cisa.gov/binding-operational-directive-22-01\">BOD 22-01</a>. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s Known Exploited Vulnerabilities (KEV) catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV catalog? Submit for potential addition: <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 15 Jun 26 12:00:00 +0000",
        "last_updated": "Mon, 15 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/12/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/12/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35273\" target=\"_blank\">CVE-2026-35273</a> Oracle PeopleSoft Enterprise PeopleTools Missing Authentication for Critical Function Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating <a href=\"https://www.cisa.gov/news-events/directives/bod-22-01-reducing-significant-risk-known-exploited-vulnerabilities-revoked\">BOD 22-01</a>. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit for potential addition: <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 12 Jun 26 12:00:00 +0000",
        "last_updated": "Fri, 12 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/11/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/11/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-10520\" target=\"_blank\">CVE-2026-10520</a> Ivanti Sentry OS Command Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating <a href=\"https://www.cisa.gov/news-events/directives/bod-22-01-reducing-significant-risk-known-exploited-vulnerabilities-revoked\">BOD 22-01</a>. BOD 26-04 reinforces the importance of the KEV catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit for potential addition: <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 11 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 11 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-01",
        "title": "Yarbo Android/iOS Mobile Application and Cloud Infrastructure",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-162-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to obtain hard-coded credentials, gain access to telemetry data, and potentially send operational commands to the robot fleet.</strong></p>\n<p>The following versions of Yarbo Android/iOS Mobile Application and Cloud Infrastructure are affected:</p>\n<ul>\n<li>Yarbo Android/IOS mobile application</li>\n<li>Cloud MQTT infrastructure vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Yarbo</td>\n<td>Yarbo Android/iOS Mobile Application and Cloud Infrastructure</td>\n<td>Use of Hard-coded Credentials, Missing Authorization</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-10557</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Yarbo Android and iOS applications contain hard-coded MQTT broker credentials that are identical for all users and all devices. These credentials are embedded in the application binary and are readily extractable via APK decompilation. The credentials provide access to cloud MQTT brokers carrying real-time telemetry for the entire global Yarbo robot fleet. They allow both wildcard subscription to all robot telemetry topics and publishing to any robot's command topic using only the robot's serial number..</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-10557\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Yarbo Android/iOS Mobile Application and Cloud Infrastructure</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Yarbo</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Yarbo Yarbo Android/IOS mobile application: &lt;v3.17.4, Yarbo Cloud MQTT infrastructure: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Yarbo recommends users update the Yarbo mobile app to 3.17.4 or later. Server-side broker authorization will be enforced automatically upon deployment of the May 2026 update. No user action is required.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-7368</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Yarbo cloud does not enforce per-device or per-user authorization. Any client possessing valid credentials, whether the shared hard-coded credentials or legitimate per-user credentials, can subscribe to wildcard topics covering all robots globally, and can publish to any robot's command topic using only the robot's serial number (disclosed in the telemetry stream). Even after removal of hard-coded credentials from the app, a single compromised credential could still provide fleet-wide access without per-device access controls.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-7368\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Yarbo Android/iOS Mobile Application and Cloud Infrastructure</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Yarbo</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Yarbo Yarbo Android/IOS mobile application: &lt;v3.17.4, Yarbo Cloud MQTT infrastructure: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Yarbo recommends users update the Yarbo mobile app to 3.17.4 or later. Server-side broker authorization will be enforced automatically upon deployment of the May 2026 update. No user action is required.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Markus Lassfolk of Truesec reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-11</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 11 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 11 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-02",
        "title": "Naxclow IoT Platform",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-162-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to impersonate devices, intercept or manipulate communications, harvest sensitive credentials at scale, or gain unauthorized access.</strong></p>\n<p>The following versions of Naxclow IoT Platform are affected:</p>\n<ul>\n<li>Smart Doorbell X3 vers:all/*&nbsp;</li>\n<li>X Smart Home vers:all/*&nbsp;</li>\n<li>V720 vers:all/*&nbsp;</li>\n<li>ix cam vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Naxclow</td>\n<td>Naxclow IoT Platform</td>\n<td>Authorization Bypass Through User-Controlled Key, Missing Authorization, Not Using Password Aging, Use of Hard-coded Cryptographic Key, Generation of Predictable Numbers or Identifiers, Insertion of Sensitive Information into Externally-Accessible File or Directory</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-42947</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A flaw in Naxclow's platform's onboarding workflow allows an attacker to replay a confirm-then-bind sequence to silently reassign a device to an arbitrary account. Because the affected endpoints validate request signatures but do not confirm legitimate ownership, an attacker with any account can take over a device without user interaction while the device remains online and unaware.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42947\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/639.html\">CWE-639 Authorization Bypass Through User-Controlled Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50108</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Naxclow platform API that returns device relay registration details exposes a persistent credential without verifying that the requester is the legitimate device or owner. An actor able to present a platform-valid request signature can retrieve credentials for arbitrary devices and register on the relay as that device, enabling interception and disruption of its communications.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50108\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50101</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Naxclow devices use a server-side, per-device relay credential that never rotates and is re-issued to the device on each boot. Because this credential remains valid indefinitely and cannot be reset or revoked by the legitimate owner, any party that obtains it through any exposure path can maintain persistent access to the device's relay channel. This enables long-term impersonation or interception, even after factory resets or re-onboarding.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50101\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/262.html\">CWE-262 Not Using Password Aging</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-28742</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Naxclow devices use a uniform request-signing scheme based on a hard-coded, platform-wide salt embedded in every firmware image. Once this salt is recovered from any device, an attacker can generate valid signatures for arbitrary device or account operations due to the absence of per-device keys, server-side nonce tracking, or replay protections. Combined with the system's use of plain HTTP for control-plane traffic, the construction enables broad request forgery and impersonation across the platform.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-28742\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-42932</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Naxclow device identifiers use fixed manufacturing prefixes combined with sequential counters, producing a fully predictable and enumerable identifier space. Because the platform also exposes an endpoint that reveals the current identifier high-water mark, the active fleet can be enumerated.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42932\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/340.html\">CWE-340 Generation of Predictable Numbers or Identifiers</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50244</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Naxclow platform exposes a registration endpoint that accepts signed requests containing a batch prefix and an arbitrary caller-supplied account identifier, without validating any ownership relationship. Each call mints a new sequential device identifier and returns the current high-water counter value for the batch, allowing callers to measure and enumerate the active device space. The endpoint's behavior enables precise fleet enumeration.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50244\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50099</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>During WiFi association, Naxclow device firmware prints the host network's SSID, PSK, and negotiated WPA keys in cleartext to an exposed UART console on production hardware. The UART pads are labeled, run with default serial settings, and drop to an interactive RT-Thread shell that permits arbitrary memory reads, enabling full firmware extraction. An attacker with brief physical access, common for outdoor-mounted devices, can therefore recover WiFi credentials and bootstrap firmware-side attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50099\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Naxclow IoT Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Naxclow</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Naxclow Smart Doorbell X3: vers:all/*, Naxclow X Smart Home: vers:all/*, Naxclow V720: vers:all/*, Naxclow ix cam: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Naxclow did not respond to CISA's attempts to coordinate these vulnerabilities. Users should contact Naxclow for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/538.html\">CWE-538 Insertion of Sensitive Information into Externally-Accessible File or Directory</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Temuri Takalandze reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-11</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 11 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 11 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-03",
        "title": "Brickcom Cameras",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-162-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-162-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow a remote unauthenticated attacker to gain unauthorized access to live video feeds, retrieve sensitive visual information from affected premises, and obtain administrative control of the device.</strong></p>\n<p>The following versions of Brickcom Cameras are affected:</p>\n<ul>\n<li>Brickcom Cube 3.2.3.5.6</li>\n<li>Brickcom Dome 3.2.3.5.6&nbsp;</li>\n<li>Brickcom Bullet 3.2.3.5.6&nbsp;</li>\n<li>Brickcom Box 3.2.3.5.6</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.7</td>\n<td>Brickcom</td>\n<td>Brickcom Cameras</td>\n<td>Missing Authentication for Critical Function, Use of Default Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Financial Services, Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50245</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product allows unauthenticated access to live snapshot images via the /ONVIF endpoint and no authentication is required to retrieve still images from the camera feed.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50245\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Brickcom Cameras</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Brickcom</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Brickcom Brickcom Cube: 3.2.3.5.6, Brickcom Brickcom Dome: 3.2.3.5.6, Brickcom Brickcom Bullet: 3.2.3.5.6, Brickcom Brickcom Box: 3.2.3.5.6</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Brickcom did not respond to CISAs request for coordination. Users are encouraged to reach out to Brickcom for support https://www.brickcom.com/case/<br><a href=\"https://www.brickcom.com/case/\">https://www.brickcom.com/case/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50005</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product ships with default credentials that allows any unauthenticated remote attacker to silently access camera feeds.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50005\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Brickcom Cameras</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Brickcom</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Brickcom Brickcom Cube: 3.2.3.5.6, Brickcom Brickcom Dome: 3.2.3.5.6, Brickcom Brickcom Bullet: 3.2.3.5.6, Brickcom Brickcom Box: 3.2.3.5.6</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Brickcom did not respond to CISAs request for coordination. Users are encouraged to reach out to Brickcom for support https://www.brickcom.com/case/<br><a href=\"https://www.brickcom.com/case/\">https://www.brickcom.com/case/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1392.html\">CWE-1392 Use of Default Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>CISA discovered the PoCs (Proof of Concept) as authored by parsa rezaie khiabanloo</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-11</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 11 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 11 Jun 26 12:00:00 +0000"
    }
]