Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jun 25, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Using SASE in a Modern TIC 3.0 Solution

Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based…
Read full source summary
Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based architectures, advance zero trust adoption, and improve visibility and control across distributed environments will benefit from this guidance. To learn more about ZT principles, visit Zero Trust. CISA Product Survey We welcome your feedback. CISA Product Survey
· CISA Cybersecurity Advisory

Hubbell Aclara Metrum Cellular Web Interface

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 Hubbell Hubbell Aclara Metrum…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 Hubbell Hubbell Aclara Metrum Cellular Web Interface Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1840 The Aclara Metrum Cellular Web Interface is vulnerable to unauthorized access due to the absence of authentication controls on critical system functions. This weakness exposes essential configuration settings, allowing attackers to alter operational parameters and trigger system restarts without restriction. Such unauthorized changes can disrupt normal functionality and, if performed repeatedly, may lead to a loss of communications to the device. View CVE Details Affected Products Hubbell Aclara Metrum Cellular Web Interface Vendor: Hubbell Product Version: Hubbell Aclara Metrum Cellular Web Interface: <v2.1.0.105 Product Status: known_affected Remediations Mitigation Hubbell encourages users to update their firmware to v2.1.0.105 in order to minimize network exposure and ensure that devices are not accessible from the Internet. Users can download version 2.1.0.105 from: https://aclara.my.site.com/AclaraConnect/s/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Abhirup Konwar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-23 Date Revision Summary 2026-06-23 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens WinCC Certificate Manager

View CSAF Summary WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens WinCC Certificate…
Read full source summary
View CSAF Summary WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens WinCC Certificate Manager are affected: SIMATIC WinCC Unified PC Runtime V16 vers:all/* SIMATIC WinCC Unified PC Runtime V17 vers:all/* SIMATIC WinCC Unified PC Runtime V18 vers:all/* SIMATIC WinCC Unified PC Runtime V19 vers:all/* SIMATIC WinCC Unified PC Runtime V20 vers:all/* SIMATIC WinCC Unified PC Runtime V21 vers:intdot/<21.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens WinCC Certificate Manager Cleartext Storage in a File or on Disk Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-24349 Insufficient protection of key material in WinCC Certificate Manager that could allow an attacker to extract sensitive information. View CVE Details Affected Products Siemens WinCC Certificate Manager Vendor: Siemens Product Version: SIMATIC WinCC Unified PC Runtime V16, SIMATIC WinCC Unified PC Runtime V17, SIMATIC WinCC Unified PC Runtime V18, SIMATIC WinCC Unified PC Runtime V19, SIMATIC WinCC Unified PC Runtime V20, SIMATIC WinCC Unified PC Runtime V21 Product Status: known_affected Remediations Mitigation The affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. No fix planned Currently no fix is planned Vendor fix Update to V21 Update 2 or later version https://support.industry.siemens.com/cs/ww/en/view/109991140/ Relevant CWE: CWE-313 Cleartext Storage in a File or on Disk Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-063511 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Publication Date 2026-06-23 2 Initial CISA Republication of Siemens ProductCERT SSA-063511 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Freelance Security Lock

View CSAF Summary Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. The following versions of ABB Freelance Security Lock are affected: ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2013…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. The following versions of ABB Freelance Security Lock are affected: ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.6 ABB ABB Freelance Security Lock Authentication Bypass by Primary Weakness Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7064 An attacker is able to attack Freelance user management when Security Lock is enabled. The precondition is that the attacker bypasses Freelance Operations which blocks access to the Windows operating system. This bypass can be achieved via undocumented or special key combinations available on modern keyboards. These combinations may allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. View CVE Details Affected Products ABB Freelance Security Lock Vendor: ABB Product Version: ABB ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions): vers:all/* Product Status: known_affected Remediations Mitigation For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&LanguageCode=en&DocumentPartId=&Action=Launch), CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json). https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&LanguageCode=en&DocumentPartId=&Action=Launch) CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json). https://psirt.abb.com/csaf/2026/7paa020361.json Relevant CWE: CWE-305 Authentication Bypass by Primary Weakness Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.6 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L Acknowledgments Gergely Regweld Szini reported this vulnerability to ABB Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-06-10 Date Revision Summary 2026-06-10 1 Initial Publication 2026-06-23 2 Initial Republication of ABB PSIRT 7PAA020361 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SINEC INS

View CSAF Summary SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. The following versions of Siemens SINEC INS are affected: SINEC INS vers:intdot/<1.0.2.6 CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens SINEC INS Improper Neutralization of Special Elements used in an OS Command…
Read full source summary
View CSAF Summary SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. The following versions of Siemens SINEC INS are affected: SINEC INS vers:intdot/<1.0.2.6 CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens SINEC INS Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Path Traversal: '/dir/../filename', Execution with Unnecessary Privileges, Use of a One-Way Hash with a Predictable Salt Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-46746 The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on the underlying operating system with the privileges of the affected service user (sinecins). View CVE Details Affected Products Siemens SINEC INS Vendor: Siemens Product Version: SINEC INS Product Status: known_affected Remediations Vendor fix Update to V1.0 SP2 Update 6 or later version https://support.industry.siemens.com/cs/ww/en/view/110002283/ Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-46747 The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations. View CVE Details Affected Products Siemens SINEC INS Vendor: Siemens Product Version: SINEC INS Product Status: known_affected Remediations Vendor fix Update to V1.0 SP2 Update 6 or later version https://support.industry.siemens.com/cs/ww/en/view/110002283/ Relevant CWE: CWE-26 Path Traversal: '/dir/../filename' Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N CVE-2026-46748 The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system. View CVE Details Affected Products Siemens SINEC INS Vendor: Siemens Product Version: SINEC INS Product Status: known_affected Remediations Vendor fix Update to V1.0 SP2 Update 6 or later version https://support.industry.siemens.com/cs/ww/en/view/110002283/ Relevant CWE: CWE-250 Execution with Unnecessary Privileges Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-46749 The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access. View CVE Details Affected Products Siemens SINEC INS Vendor: Siemens Product Version: SINEC INS Product Status: known_affected Remediations Vendor fix Update to V1.0 SP2 Update 6 or later version https://support.industry.siemens.com/cs/ww/en/view/110002283/ Relevant CWE: CWE-760 Use of a One-Way Hash with a Predictable Salt Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-860189 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Publication Date 2026-06-23 2 Initial CISA Republication of Siemens ProductCERT SSA-860189 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Impact of Linux Kernel vulnerabilities on B&R products

View CSAF Summary B&R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this…
Read full source summary
View CSAF Summary B&R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this advisory, B&R had no evidence of active exploitation targeting B&R products. The following versions of Impact of Linux Kernel vulnerabilities on B&R products are affected: Linux for B&R <=12 APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602 X20EDS410 /all CVSS Vendor Equipment Vulnerabilities v3 7.8 B&R Industrial Automation GmbH Impact of Linux Kernel vulnerabilities on B&R products Incorrect Resource Transfer Between Spheres, Write-what-where Condition, Improper Privilege Management, Out-of-bounds Write, Multiple Releases of Same Resource or Handle Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 In the Linux kernel, the following vulnerability has been resolved: crypto: algif_aead - Revert to operating out-of-place This mostly reverts commit 72548b093ee3 except for the copying of the associated data. There is no benefit in operating in-place in algif_aead since the source and destination come from different mappings. Get rid of all the complexity added for in-place operation and just copy the AD directly. View CVE Details Affected Products Impact of Linux Kernel vulnerabilities on B&R products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH Linux for B&R <=12, B&R Industrial Automation GmbH APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602, B&R Industrial Automation GmbH X20EDS410 /all Product Status: fixed, known_affected Remediations Vendor fix For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory. Mitigation Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update && sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo "install algif_aead /bin/false" > /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2>/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG Relevant CWE: CWE-669 Incorrect Resource Transfer Between Spheres Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:H/RC:C CVE-2026-43284 In the Linux kernel, the following vulnerability has been resolved: xfrm: esp: avoid in-place decrypt on shared skb frags MSG_SPLICE_PAGES can attach pages from a pipe directly to an skb. TCP marks such skbs with SKBFL_SHARED_FRAG after skb_splice_from_iter(), so later paths that may modify packet data can first make a private copy. The IPv4/IPv6 datagram append paths did not set this flag when splicing pages into UDP skbs. That leaves an ESP-in-UDP packet made from shared pipe pages looking like an ordinary uncloned nonlinear skb. ESP input then takes the no-COW fast path for uncloned skbs without a frag_list and decrypts in place over data that is not owned privately by the skb. Mark IPv4/IPv6 datagram splice frags with SKBFL_SHARED_FRAG, matching TCP. Also make ESP input fall back to skb_cow_data() when the flag is present, so ESP does not decrypt external-ly backed frags in place. Private nonlinear skb frags still use the existing fast path. This intentionally does not change ESP output. In esp_output_head(), the path that appends the ESP trailer to existing skb tailroom without calling skb_cow_data() is not reachable for nonlinear skbs: skb_tailroom() returns zero when skb->data_len is nonzero, while ESP tailen is positive. Thus ESP output will either use the separate destination-frag path or fall back to skb_cow_data(). View CVE Details Affected Products Impact of Linux Kernel vulnerabilities on B&R products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH Linux for B&R <=12, B&R Industrial Automation GmbH APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602, B&R Industrial Automation GmbH X20EDS410 /all Product Status: fixed, known_affected Remediations Vendor fix For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory. Mitigation Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update && sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo "install algif_aead /bin/false" > /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2>/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG Relevant CWE: CWE-123 Write-what-where Condition Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2026-46333 In the Linux kernel, the following vulnerability has been resolved: ptrace: slightly saner 'get_dumpable()' logic The 'dumpability' of a task is fundamentally about the memory image of the task - the concept comes from whether it can core dump or not - and makes no sense when you don't have an associated mm. And almost all users do in fact use it only for the case where the task has a mm pointer. But we have one odd special case: ptrace_may_access() uses 'dumpable' to check various other things entirely independently of the MM (typically explicitly using flags like PTRACE_MODE_READ_FSCREDS). Including for threads that no longer have a VM (and maybe never did, like most kernel threads). It's not what this flag was designed for, but it is what it is. The ptrace code does check that the uid/gid matches, so you do have to be uid-0 to see kernel thread details, but this means that the traditional "drop capabilities" model doesn't make any difference for this all. Make it all make a *bit* more sense by saying that if you don't have a MM pointer, we'll use a cached "last dumpability" flag if the thread ever had a MM (it will be zero for kernel threads since it is never set), and require a proper CAP_SYS_PTRACE capability to override. View CVE Details Affected Products Impact of Linux Kernel vulnerabilities on B&R products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH Linux for B&R <=12, B&R Industrial Automation GmbH APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602, B&R Industrial Automation GmbH X20EDS410 /all Product Status: fixed, known_affected Remediations Vendor fix For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory. Mitigation Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update && sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo "install algif_aead /bin/false" > /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2>/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG Relevant CWE: CWE-269 Improper Privilege Management Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N CVE-2026-46300 In the Linux kernel, the following vulnerability has been resolved: net: skbuff: preserve shared-frag marker during coalescing skb_try_coalesce() can attach paged frags from @from to @to. If @from has SKBFL_SHARED_FRAG set, the resulting @to skb can contain the same externally-owned or page-cache-backed frags, but the shared-frag marker is currently lost. That breaks the invariant relied on by later in-place writers. In particular, ESP input checks skb_has_shared_frag() before deciding whether an uncloned nonlinear skb can skip skb_cow_data(). If TCP receive coalescing has moved shared frags into an unmarked skb, ESP can see skb_has_shared_frag() as false and decrypt in place over page-cache backed frags. Propagate SKBFL_SHARED_FRAG when skb_try_coalesce() transfers paged frags. The tailroom copy path does not need the marker because it copies bytes into @to's linear data rather than transferring frag descriptors.. View CVE Details Affected Products Impact of Linux Kernel vulnerabilities on B&R products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH Linux for B&R <=12, B&R Industrial Automation GmbH APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602, B&R Industrial Automation GmbH X20EDS410 /all Product Status: fixed, known_affected Remediations Vendor fix For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory. Mitigation Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update && sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo "install algif_aead /bin/false" > /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2>/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-43494 In the Linux kernel, the following vulnerability has been resolved: net/rds: reset op_nents when zerocopy page pin fails When iov_iter_get_pages2() fails in rds_message_zcopy_from_user(), the pinned pages are released with put_page(), and rm->data.op_mmp_znotifier is cleared. But we fail to properly clear rm->data.op_nents. Later when rds_message_purge() is called from rds_sendmsg() the cleanup loop iterates over the incorrectly non zero number of op_nents and frees them again. Fix this by properly resetting op_nents when it should be in rds_message_zcopy_from_user(). View CVE Details Affected Products Impact of Linux Kernel vulnerabilities on B&R products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH Linux for B&R <=12, B&R Industrial Automation GmbH APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602, B&R Industrial Automation GmbH X20EDS410 /all Product Status: fixed, known_affected Remediations Vendor fix For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory. Mitigation Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section “General security recommendations” for further advise on how to keep your system secure. Workaround Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update && sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo "install algif_aead /bin/false" > /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2>/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG Relevant CWE: CWE-1341 Multiple Releases of Same Resource or Handle Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by B&R. B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently asked questions What causes the vulnerabilities? - The vulnerabilities are caused by a vulnerable Linux Kernel component. What might an attacker use the vulnerability to do? - An authenticated attacker with low privileges may elevate privileges to root. Could the vulnerabilities be exploited remotely? - Yes, an attacker with privileges to login in a vulnerable system node could exploit these vulnerabilities. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had B&R received any reports that these vulnerabilities were being exploited? - B&R is aware of reports indicating that these vulnerabilities had been exploited at the time this security advisory was originally issued; however, no exploitation has been observed in B&R products. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT SA26P010 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-11 Date Revision Summary 2026-06-11 1 Initial version. 2026-06-18 2 Updating the CWE classification for CVE-2026-43494. 2026-06-23 3 Initial CISA Republication of ABB PSIRT SA26P010 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SIPROTEC 5 Using DIGSI5 Protocol

View CSAF Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86…
Read full source summary
View CSAF Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86 are advised to upgrade to version 10.00 or later, while the remaining models should upgrade to version 9.90 or later. These versions introduce an allow-list feature that restricts arbitrary file uploads and reduces the risk associated with this vulnerability. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 Using DIGSI5 Protocol are affected: SIPROTEC 5 6MD84 (CP300) vers:all/* SIPROTEC 5 6MD85 (CP200) vers:all/* SIPROTEC 5 6MD85 (CP300) vers:all/* SIPROTEC 5 6MD86 (CP200) vers:all/* SIPROTEC 5 6MD86 (CP300) vers:all/* SIPROTEC 5 6MD89 (CP300) vers:all/* SIPROTEC 5 6MU85 (CP300) vers:all/* SIPROTEC 5 7KE85 (CP200) vers:all/* SIPROTEC 5 7KE85 (CP300) vers:all/* SIPROTEC 5 7SA82 (CP100) vers:all/* SIPROTEC 5 7SA82 (CP150) vers:all/* SIPROTEC 5 7SA86 (CP200) vers:all/* SIPROTEC 5 7SA86 (CP300) vers:all/* SIPROTEC 5 7SA87 (CP200) vers:all/* SIPROTEC 5 7SA87 (CP300) vers:all/* SIPROTEC 5 7SD82 (CP100) vers:all/* SIPROTEC 5 7SD82 (CP150) vers:all/* SIPROTEC 5 7SD86 (CP200) vers:all/* SIPROTEC 5 7SD86 (CP300) vers:all/* SIPROTEC 5 7SD87 (CP200) vers:all/* SIPROTEC 5 7SD87 (CP300) vers:all/* SIPROTEC 5 7SJ81 (CP100) vers:all/* SIPROTEC 5 7SJ81 (CP150) vers:all/* SIPROTEC 5 7SJ82 (CP100) vers:all/* SIPROTEC 5 7SJ82 (CP150) vers:all/* SIPROTEC 5 7SJ85 (CP200) vers:all/* SIPROTEC 5 7SJ85 (CP300) vers:all/* SIPROTEC 5 7SJ86 (CP200) vers:all/* SIPROTEC 5 7SJ86 (CP300) vers:all/* SIPROTEC 5 7SK82 (CP100) vers:all/* SIPROTEC 5 7SK82 (CP150) vers:all/* SIPROTEC 5 7SK85 (CP200) vers:all/* SIPROTEC 5 7SK85 (CP300) vers:all/* SIPROTEC 5 7SL82 (CP100) vers:all/* SIPROTEC 5 7SL82 (CP150) vers:all/* SIPROTEC 5 7SL86 (CP200) vers:all/* SIPROTEC 5 7SL86 (CP300) vers:all/* SIPROTEC 5 7SL87 (CP200) vers:all/* SIPROTEC 5 7SL87 (CP300) vers:all/* SIPROTEC 5 7SS85 (CP200) vers:all/* SIPROTEC 5 7SS85 (CP300) vers:all/* SIPROTEC 5 7ST85 (CP200) vers:all/* SIPROTEC 5 7ST85 (CP300) vers:all/* SIPROTEC 5 7ST86 (CP300) vers:all/* SIPROTEC 5 7SX82 (CP150) vers:all/* SIPROTEC 5 7SX85 (CP300) vers:all/* SIPROTEC 5 7SY82 (CP150) vers:all/* SIPROTEC 5 7UM85 (CP300) vers:all/* SIPROTEC 5 7UT82 (CP100) vers:all/* SIPROTEC 5 7UT82 (CP150) vers:all/* SIPROTEC 5 7UT85 (CP200) vers:all/* SIPROTEC 5 7UT85 (CP300) vers:all/* SIPROTEC 5 7UT86 (CP200) vers:all/* SIPROTEC 5 7UT86 (CP300) vers:all/* SIPROTEC 5 7UT87 (CP200) vers:all/* SIPROTEC 5 7UT87 (CP300) vers:all/* SIPROTEC 5 7VE85 (CP300) vers:all/* SIPROTEC 5 7VK87 (CP200) vers:all/* SIPROTEC 5 7VK87 (CP300) vers:all/* SIPROTEC 5 7VU85 (CP300) vers:all/* SIPROTEC 5 Compact 7SX800 (CP050) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens SIPROTEC 5 Using DIGSI5 Protocol Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40808 The affected application allows authenticated users to upload arbitrary files using DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, that could cause denial of service condition and potentially lead to code execution. View CVE Details Affected Products Siemens SIPROTEC 5 Using DIGSI5 Protocol Vendor: Siemens Product Version: SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP200), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP200), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5 6MU85 (CP300), SIPROTEC 5 7KE85 (CP200), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA82 (CP100), SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SA86 (CP200), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP200), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD82 (CP100), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SD86 (CP200), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP200), SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ81 (CP100), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP100), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5 7SJ85 (CP200), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP200), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK82 (CP100), SIPROTEC 5 7SK82 (CP150), SIPROTEC 5 7SK85 (CP200), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL82 (CP100), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SL86 (CP200), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87 (CP200), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP200), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP200), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT82 (CP100), SIPROTEC 5 7UT82 (CP150), SIPROTEC 5 7UT85 (CP200), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP200), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP200), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP200), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300), SIPROTEC 5 Compact 7SX800 (CP050) Product Status: known_affected Remediations Mitigation Users are advised to upgrade to V9.90 or later, which introduces an allow-list feature that restricts arbitrary file uploads Mitigation Apply password protection to all DIGSI connections to ensure secure communication Mitigation For DIGSI access provision your own certificates signed by your customer PKI as described in https://support.industry.siemens.com/cs/document/109768375 Mitigation For the available devices [CP050, CP100, CP150 and CP300], activate role-based access control (RBAC) in the device (supported in SIPROTEC 5 firmware versions V7.80 and higher) Mitigation Users are advised to upgrade to V10.00 or later, which introduces an allow-list feature that restricts arbitrary file uploads No fix planned Currently no fix is planned None available Currently no fix is available Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-139483 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Publication Date 2026-06-23 2 Initial CISA Republication of Siemens ProductCERT SSA-139483 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-67038 Lantronix EDS5000 Code Injection Vulnerability CVE-2026-34908 Ubiquiti UniFi OS Improper Access Control Vulnerability CVE-2026-34909 Ubiquiti UniFi OS Path Traversal Vulnerability CVE-2026-34910 Ubiquiti UniFi OS Improper Input Validation Vulnerability These types of…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-67038 Lantronix EDS5000 Code Injection Vulnerability CVE-2026-34908 Ubiquiti UniFi OS Improper Access Control Vulnerability CVE-2026-34909 Ubiquiti UniFi OS Path Traversal Vulnerability CVE-2026-34910 Ubiquiti UniFi OS Improper Input Validation Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Siemens Products using OpenSSL

View CSAF Summary OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes…
Read full source summary
View CSAF Summary OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Products using OpenSSL are affected: AI Lightweight Inference Server vers:all/* (CVE-2025-15467) Connector for Azure vers:intdot/<1.8.0 (CVE-2025-15467) Databus vers:intdot/<3.3.2 (CVE-2025-15467) HiMed Cockpit vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) vers:all/* (CVE-2025-15467) SCALANCE LPE9403 (6GK5998-3GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2025-15467) SCALANCE M804PB (6GK5804-0AP00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE M812-1 ADSL-Router family vers:all/* (CVE-2025-15467) SCALANCE M816-1 ADSL-Router family vers:all/* (CVE-2025-15467) SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) vers:all/* (CVE-2025-15467) SCALANCE M874-2 (6GK5874-2AA00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE M874-3 (6GK5874-3AA00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) vers:all/* (CVE-2025-15467) SCALANCE M876-3 (6GK5876-3AA02-2BA2) vers:all/* (CVE-2025-15467) SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) vers:all/* (CVE-2025-15467) SCALANCE M876-4 (6GK5876-4AA10-2BA2) vers:all/* (CVE-2025-15467) SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) vers:all/* (CVE-2025-15467) SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) vers:all/* (CVE-2025-15467) SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) vers:all/* (CVE-2025-15467) SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) vers:all/* (CVE-2025-15467) SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) vers:all/* (CVE-2025-15467) SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) vers:all/* (CVE-2025-15467) SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) vers:all/* (CVE-2025-15467) SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) vers:all/* (CVE-2025-15467) SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) vers:all/* (CVE-2025-15467) SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) vers:all/* (CVE-2025-15467) SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) vers:all/* (CVE-2025-15467) SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) vers:all/* (CVE-2025-15467) SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) vers:all/* (CVE-2025-15467) SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE SC622-2C (6GK5622-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE SC626-2C (6GK5626-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE SC632-2C (6GK5632-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE SC636-2C (6GK5636-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE SC642-2C (6GK5642-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE SC646-2C (6GK5646-2GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) vers:all/* (CVE-2025-15467) SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) vers:all/* (CVE-2025-15467) SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) vers:all/* (CVE-2025-15467) SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) vers:all/* (CVE-2025-15467) SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) vers:all/* (CVE-2025-15467) SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) vers:all/* (CVE-2025-15467) SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) vers:all/* (CVE-2025-15467) SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) vers:all/* (CVE-2025-15467) SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) vers:all/* (CVE-2025-15467) SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) vers:all/* (CVE-2025-15467) SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) vers:all/* (CVE-2025-15467) SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) vers:all/* (CVE-2025-15467) SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) vers:all/* (CVE-2025-15467) SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) vers:all/* (CVE-2025-15467) SCALANCE XC316-8 (6GK5324-8TS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XC324-4 (6GK5328-4TS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) vers:all/* (CVE-2025-15467) SCALANCE XC332 (6GK5332-0GA00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XC416-8 (6GK5424-8TR00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XC424-4 (6GK5428-4TR00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XC432 (6GK5432-0GR00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE XR302-32 (6GK5334-5TS00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR302-32 (6GK5334-5TS00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR302-32 (6GK5334-5TS00-4AR3) vers:all/* (CVE-2025-15467) SCALANCE XR322-12 (6GK5334-3TS00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR322-12 (6GK5334-3TS00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR322-12 (6GK5334-3TS00-4AR3) vers:all/* (CVE-2025-15467) SCALANCE XR326-8 (6GK5334-2TS00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR326-8 (6GK5334-2TS00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR326-8 (6GK5334-2TS00-4AR3) vers:all/* (CVE-2025-15467) SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) vers:all/* (CVE-2025-15467) SCALANCE XR502-32 (6GK5534-5TR00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR502-32 (6GK5534-5TR00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR502-32 (6GK5534-5TR00-4AR3) vers:all/* (CVE-2025-15467) SCALANCE XR522-12 (6GK5534-3TR00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR522-12 (6GK5534-3TR00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR522-12 (6GK5534-3TR00-4AR3) vers:all/* (CVE-2025-15467) SCALANCE XR524-8WG (6GK5532-2SR00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR524-8WG (6GK5532-2SR00-2RR3) vers:all/* (CVE-2025-15467) SCALANCE XR524-8WG (6GK5532-2SR00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR524-8WG (6GK5532-2SR00-3RR3) vers:all/* (CVE-2025-15467) SCALANCE XR526-8 (6GK5534-2TR00-2AR3) vers:all/* (CVE-2025-15467) SCALANCE XR526-8 (6GK5534-2TR00-3AR3) vers:all/* (CVE-2025-15467) SCALANCE XR526-8 (6GK5534-2TR00-4AR3) vers:all/* (CVE-2025-15467) Shopfloor IT Suite vers:all/* (CVE-2025-15467) SIDIS Prime vers:intdot/>=4.0.700 (CVE-2025-15467) Siemens OPC UA Modelling Editor (SiOME) vers:all/* (CVE-2025-15467) SIMATIC Comfort/Mobile RT vers:all/* (CVE-2025-15467) SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) vers:all/* (CVE-2025-15467) SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) vers:all/* (CVE-2025-15467) SIMATIC HMI Basic Panels vers:intdot/<17.0.9 (CVE-2025-15467) SIMATIC HMI Comfort Panels vers:intdot/<17.0.9 (CVE-2025-15467) SIMATIC HMI Mobile Panels vers:intdot/<17.0.9 (CVE-2025-15467) SIMATIC IOT2050 (6ES7647-0BA00-1YA2) vers:all/* (CVE-2025-15467) SIMATIC IPC BX-21A vers:all/* (CVE-2025-15467) SIMATIC IPC MD-57A vers:all/* (CVE-2025-15467) SIMATIC IPC ORCLA vers:all/* (CVE-2025-15467) SIMATIC PDM V9.3 vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-0DA00) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-0DA10) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-0DA20) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-0DA30) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-1EA10) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-1EA20) vers:all/* (CVE-2025-15467) SIMATIC RTLS Locating Manager (6GT2780-1EA30) vers:all/* (CVE-2025-15467) SIMATIC STEP 7 V5 vers:intdot/<5.7.4 (CVE-2025-15467) SIMATIC Target vers:all/* (CVE-2025-15467) SIMATIC WinCC OA V3.19 vers:intdot/<3.19.024 (CVE-2025-15467) SIMATIC WinCC OA V3.20 vers:intdot/<3.20.012 (CVE-2025-15467) SIMATIC WinCC OA V3.21 vers:intdot/<3.21.02 (CVE-2025-15467) SIMATIC WinCC Runtime Advanced V17 vers:intdot/<17.0.9 (CVE-2025-15467) SIMATIC WinCC Unified Sequence vers:intdot/<21 (CVE-2025-15467) SIMATIC WinCC V7.5 vers:all/* (CVE-2025-15467) SIMATIC WinCC V8.0 vers:all/* (CVE-2025-15467) SIMATIC WinCC V8.1 vers:all/* (CVE-2025-15467) SIMOTION OACAMGEN (6AU1820-3EA20-0AB0) vers:all/* (CVE-2025-15467) SIMOVE Fleetmanager V3.1 vers:all/* (CVE-2025-15467) SIMOVE Fleetmanager V3.2 vers:all/* (CVE-2025-15467) SIMOVE Fleetmanager V3.3 vers:all/* (CVE-2025-15467) SINAMICS G200 vers:intdot/>=6.3 (CVE-2025-15467) SINAMICS G220 vers:intdot/>=6.3 (CVE-2025-15467) SINAMICS S200 vers:intdot/>=6.3 (CVE-2025-15467) SINAMICS S210 vers:intdot/>=6.3 (CVE-2025-15467) SINAMICS S220 vers:intdot/>=6.3 (CVE-2025-15467) SINEC INS vers:intdot/<1.0.2.5 (CVE-2025-15467) SINEC NMS vers:all/* (CVE-2025-15467) SINEC Security Monitor vers:all/* (CVE-2025-15467) SINUMERIK Access MyMachine /OPC UA vers:all/* (CVE-2025-15467) SIPLANT vers:all/* (CVE-2025-15467) SITRANS ASM IQ vers:all/* (CVE-2025-15467) SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ) vers:all/* (CVE-2025-15467) User Management Component (UMC) vers:intdot/<2.15.3.0 (CVE-2025-15467) Visual Inspection Cockpit vers:all/* (CVE-2025-15467) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens Products using OpenSSL Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-15467 Issue summary: Parsing CMS AuthEnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow. Impact summary: A stack buffer overflow may lead to a crash, causing Denial of Service, or potentially remote code execution. When parsing CMS AuthEnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before any authentication or tag verification occurs. Applications and services that parse untrusted CMS or PKCS#7 content using AEAD ciphers (e.g., S/MIME AuthEnvelopedData with AES-GCM) are vulnerable. Because the overflow occurs prior to authentication, no valid key material is required to trigger it. While exploitability to remote code execution depends on platform and toolchain mitigations, the stack-based write primitive represents a severe risk. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue. View CVE Details Affected Products Siemens Products using OpenSSL Vendor: Siemens Product Version: AI Lightweight Inference Server, Connector for Azure, Databus, HiMed Cockpit, RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE LPE9403 (6GK5998-3GS00-2AC2), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router family, SCALANCE M816-1 ADSL-Router family, SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SCALANCE XC316-8 (6GK5324-8TS00-2AC2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2), SCALANCE XC332 (6GK5332-0GA00-2AC2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2), SCALANCE XC432 (6GK5432-0GR00-2AC2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3), SCALANCE XR302-32 (6GK5334-5TS00-3AR3), SCALANCE XR302-32 (6GK5334-5TS00-4AR3), SCALANCE XR322-12 (6GK5334-3TS00-2AR3), SCALANCE XR322-12 (6GK5334-3TS00-3AR3), SCALANCE XR322-12 (6GK5334-3TS00-4AR3), SCALANCE XR326-8 (6GK5334-2TS00-2AR3), SCALANCE XR326-8 (6GK5334-2TS00-3AR3), SCALANCE XR326-8 (6GK5334-2TS00-4AR3), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3), SCALANCE XR502-32 (6GK5534-5TR00-2AR3), SCALANCE XR502-32 (6GK5534-5TR00-3AR3), SCALANCE XR502-32 (6GK5534-5TR00-4AR3), SCALANCE XR522-12 (6GK5534-3TR00-2AR3), SCALANCE XR522-12 (6GK5534-3TR00-3AR3), SCALANCE XR522-12 (6GK5534-3TR00-4AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2RR3), SCALANCE XR524-8WG (6GK5532-2SR00-3AR3), SCALANCE XR524-8WG (6GK5532-2SR00-3RR3), SCALANCE XR526-8 (6GK5534-2TR00-2AR3), SCALANCE XR526-8 (6GK5534-2TR00-3AR3), SCALANCE XR526-8 (6GK5534-2TR00-4AR3), Shopfloor IT Suite, SIDIS Prime, Siemens OPC UA Modelling Editor (SiOME), SIMATIC Comfort/Mobile RT, SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8), SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8), SIMATIC HMI Basic Panels, SIMATIC HMI Comfort Panels, SIMATIC HMI Mobile Panels, SIMATIC IOT2050 (6ES7647-0BA00-1YA2), SIMATIC IPC BX-21A, SIMATIC IPC MD-57A, SIMATIC IPC ORCLA, SIMATIC PDM V9.3, SIMATIC RTLS Locating Manager (6GT2780-0DA00), SIMATIC RTLS Locating Manager (6GT2780-0DA10), SIMATIC RTLS Locating Manager (6GT2780-0DA20), SIMATIC RTLS Locating Manager (6GT2780-0DA30), SIMATIC RTLS Locating Manager (6GT2780-1EA10), SIMATIC RTLS Locating Manager (6GT2780-1EA20), SIMATIC RTLS Locating Manager (6GT2780-1EA30), SIMATIC STEP 7 V5, SIMATIC Target, SIMATIC WinCC OA V3.19, SIMATIC WinCC OA V3.20, SIMATIC WinCC OA V3.21, SIMATIC WinCC Runtime Advanced V17, SIMATIC WinCC Unified Sequence, SIMATIC WinCC V7.5, SIMATIC WinCC V8.0, SIMATIC WinCC V8.1, SIMOTION OACAMGEN (6AU1820-3EA20-0AB0), SIMOVE Fleetmanager V3.1, SIMOVE Fleetmanager V3.2, SIMOVE Fleetmanager V3.3, SINAMICS G200, SINAMICS G220, SINAMICS S200, SINAMICS S210, SINAMICS S220, SINEC INS, SINEC NMS, SINEC Security Monitor, SINUMERIK Access MyMachine /OPC UA, SIPLANT, SITRANS ASM IQ, SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ), User Management Component (UMC), Visual Inspection Cockpit Product Status: known_affected Remediations Mitigation As a defense-in-depth measure, organizations may review whether affected systems are exposed to untrusted CMS/PKCS#7 content from external sources. Mitigation Do not accept files from untrusted and unvalidated sources in the affected applications Mitigation Restrict the port at the host with the DeviceConnectionProxy to secure destinations Mitigation Securing the connected email server as follows: • Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. • Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). • Ensure strong authentication to access the email server. • Keep the email server software and underlying operating system up to date with the latest security patches. Mitigation Securing the connected email server as follows: • Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. • Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). • Ensure strong authentication to access the email server. • Keep the email server software and underlying operating system up to date with the latest security patches. Mitigation The hardening instructions mentioned in the products security concept should be followed No fix planned Currently no fix is planned None available Currently no fix is available Vendor fix Update to V1.0 SP2 Update 5 or later version https://support.industry.siemens.com/cs/ww/en/view/109999722/ Vendor fix Update to V1.8.0 or later version https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html Vendor fix Update to V17 Update 9 or later version https://support.industry.siemens.com/cs/ww/en/view/109800912/ Vendor fix Update to V17.9 or later version https://support.industry.siemens.com/cs/ww/en/view/109825750/ Vendor fix Update to V17 Update 9 or later version https://support.industry.siemens.com/cs/ww/en/view/109825750/ Vendor fix Update to V2.15.3.0 or later version https://support.industry.siemens.com/cs/ww/en/view/110000730/ Vendor fix Update to V21 or later version https://support.industry.siemens.com/cs/ww/en/view/109996963/ Vendor fix Update to V3.19 P024 or later version https://support.industry.siemens.com/cs/ww/en/view/110000400/ Vendor fix Update to V3.20 P012 or later version https://support.industry.siemens.com/cs/ww/en/view/110000657/ Vendor fix Update to V3.21 P02 or later version https://support.industry.siemens.com/cs/ww/en/view/110000985/ Vendor fix Update to V3.3.2 or later version https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html Vendor fix Update to V5.7 SP4 or later version https://support.industry.siemens.com/cs/ww/en/view/109991080/ Vendor fix Contact customer support siplant-support.de@siemens.com Vendor fix Contact customer support Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-434797 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Publication Date 2026-06-23 2 Initial CISA Republication of Siemens ProductCERT SSA-434797 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Urges Hardening Fortinet Devices After Reports of Credential Exposure

Update June 22, 2026: CISA has updated this Alert to incorporate the link to Fortinet’s recent guidance on this activity. CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with…
Read full source summary
Update June 22, 2026: CISA has updated this Alert to incorporate the link to Fortinet’s recent guidance on this activity. CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. To defend against this malicious cyber activity, CISA urges impacted Fortinet customers with FortiGate appliances and associated secure sockets layer (SSL) VPN gateways to immediately: Terminate sessions and reset credentials. Terminate all active SSL VPN and administrative sessions. Reset all Fortinet VPN and administrative passwords, especially on internet-facing systems, and enforce strong password policies. Ensure secure credential storage. Confirm your organization’s use of the Password-Based Key Derivation Function 2 (PBKDF2) algorithm to store administrator credentials and remove weaker legacy hashes per Fortinet’s guidance (see, Fortinet's Technical Tip: Enforcing PBKDF2 as hash function for administrator accounts in FortiOS v7.2.11 and later). Review logs. Review firewall, VPN, authentication, and domain controller logs for lateral movement, unusual access, suspicious accounts, or unauthorized configuration changes. Enable phishing-resistant multifactor authentication (MFA). Require phishing-resistant MFA on all remote access and administrative accounts and ensure it is enforced on all external gateways and administrative interfaces. Reduce the attack surface and lock down management access. Ensure the administration of your firewall is inaccessible from the public internet; restrict Fortinet management interfaces to trusted internal networks; and remove or disable any unauthorized or unnecessary accounts. See the following resources to determine your organization’s potential impact and find additional guidance on the credentials compromised: Tech Times: Fortinet FortiGate Credential Leak Hits 73,932 Firewalls: Half the Internet-Facing Fleet SOCRadar: FortiBleed: The Compromise of 80,000+ Fortinet Firewalls Hudson Rock: FortiBleed: 75,000 Fortinet Firewalls Compromised: Global Enterprises Exposed – Claim Your Ethical Disclosure Arctic Wolf: Active FortiBleed Campaign Impacting Fortinet Devices Across 194 Countries Fortinet: Attacks at the Speed of AI Fortinet: Analysis of Reported Credential Compromise of FortiGate Devices Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.
· CISA Cybersecurity Advisory

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided…
Read full source summary
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products are affected: Easergy MiCOM C264 vers:generic/<=D7.33 (CVE-2026-4827) Easergy MiCOM P139 vers:generic/<=P139.678.700 (CVE-2026-4827) Easergy MiCOM P437 vers:generic/<=P437.678.700 (CVE-2026-4827) Easergy MiCOM P439 vers:generic/<=P439.678.700 (CVE-2026-4827) Easergy MiCOM P532 vers:generic/<=P532.678.700 (CVE-2026-4827) Easergy MiCOM P539 vers:generic/<=P539.678.700 (CVE-2026-4827) Easergy MiCOM P631 vers:generic/<=P631.678.700 (CVE-2026-4827) Easergy MiCOM P632 vers:generic/<=P632.678.700 (CVE-2026-4827) Easergy MiCOM P633 vers:generic/<=P633.678.700 (CVE-2026-4827) Easergy MiCOM P634 vers:generic/<=P634.678.700 (CVE-2026-4827) Easergy MiCOM P633 P633.680.700 (CVE-2026-4827) Easergy MiCOM P634 P634.680.700 (CVE-2026-4827) Easergy MiCOM P138 vers:generic/<=P138.677.700 (CVE-2026-4827) Easergy MiCOM P436 vers:generic/<=P436.677.701 (CVE-2026-4827) Easergy MiCOM P438 vers:generic/<=P438.677.701 (CVE-2026-4827) Easergy MiCOM P638 vers:generic/<=P638.677.700 (CVE-2026-4827) Easergy MiCOM C434 vers:generic/<=C434.679.700 (CVE-2026-4827) EcoStruxure Power Automation System Gateway (EPAS-GTW) vers:intdot/<=6.4.616.200.100 (CVE-2026-4827) EcoStruxure Power Automation System User Interface (EPAS-UI) vers:intdot/<=3.0.3 (CVE-2026-4827) EcoStruxure Power Operation vers:generic/<=2022_CU6 (CVE-2026-4827) EcoStruxure Power Operation vers:generic/<=2024_CU2 (CVE-2026-4827) iPMFLS vers:intdot/<=64.2025.0.13 (CVE-2026-4827) PowerLogic P5 Protection Relay vers:intdot/<=02.502.103 (CVE-2026-4827) PowerLogic P7 Protection and Control Platform vers:intdot/<=02.002.002 (CVE-2026-4827) PowerLogic T300 vers:intdot/<=2.9.4 (CVE-2026-4827) PowerLogic T500 vers:intdot/<=11.08.02 (CVE-2026-4827) Saitel DP vers:intdot/<=11.06.36 () EasyLogic T150 (formerly Saitel DR) vers:intdot/<=11.06.30 () Easergy MiCOM C264 D7.34 () Easergy C5 vers:intdot/<=1.1.17 (CVE-2026-4827) Easergy C5 1.1.18 () Easergy MiCOM P139 version P139.678.700 () Easergy MiCOM P439 P439.678.700 () Easergy MiCOM P539 P539.678.700 () Easergy MiCOM P632 P632.678.700 () Easergy MiCOM P633 P633.680.701 () Easergy MiCOM P634 P634.680.701 () Easergy MiCOM P633 P633.678.700 () Easergy MiCOM P138 P138.677.701 () Easergy MiCOM C434 C434.679.700 () Saitel DR 11.06.31 () EcoStruxure Power Automation System Gateway (EPAS-GTW) 6.4.610.500.101 () EcoStruxure Power Automation Automation System User Interface (EPAS-UI) 3.0.4 () EcoStruxure Power Operation 2022_CU7 () EcoStruxure Power Operation (EPO) 2024_CU3 () iPMFLS 64.2025.0.14 () PowerLogic P5 Protection Relay 02.503.101 () PowerLogic P7 Protection and Control Platform 02.003.001 () PowerLogic T300 2.9.5 () PowerLogic T500 11.08.03 () Saitel DP 11.06.37 () Easergy MiCOM P40 Series vers:all/* (CVE-2026-4827) CVSS Vendor Equipment Vulnerabilities v3 8.3 Schneider Electric Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products Insufficient Entropy Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-4827 CWE-331 Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections. View CVE Details Affected Products Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products Vendor: Schneider Electric Product Version: Easergy MiCOM C264 Versions D7.33 and prior, Easergy MiCOM P139 version prior to P139.678.700, Easergy MiCOM P437 version prior to P437.678.700, Easergy MiCOM P439 version prior to P439.678.700, Easergy MiCOM P532 version prior to P532.678.700, Easergy MiCOM P539 version prior to P539.678.700, Easergy MiCOM P631 version prior to P631.678.700, Easergy MiCOM P632 version prior to P632.678.700, Easergy MiCOM P633 version prior to P633.678.700, Easergy MiCOM P634 version prior to P634.678.700, Easergy MiCOM P633 version P633.680.700, Easergy MiCOM P634 version P634.680.700 , Easergy MiCOM P138 version prior to P138.677.700, Easergy MiCOM P436 version prior to P436.677.701, Easergy MiCOM P438 version prior to P438.677.701, Easergy MiCOM P638 version prior to P638.677.700, Easergy MiCOM C434 version prior to C434.679.700, EcoStruxure Power Automation System Gateway (EPAS-GTW) Version 6.4.616.200.100 and prior, EcoStruxure Power Automation System User Interface (EPAS-UI) Version 3.0.3 and prior, EcoStruxure Power Operation (EPO) 2022 CU6 and prior, EcoStruxure Power Operation (EPO) 2024 CU2 and prior, iPMFLS Version 64.2025.0.13 and prior, PowerLogic P5 Protection Relay V02.502.103 and prior, PowerLogic P7 Protection and Control Platform V02.002.002 and prior, PowerLogic T300 Version 2.9.4 and prior, PowerLogic T500 Version 11.08.02 and prior, Easergy C5 Version 1.1.17 and prior, Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L and all firmware versions Product Status: fixed, known_affected Remediations Vendor fix Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required Vendor fix Version 1.1.18 of Easergy C5 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required Vendor fix Version P139.678.700 Easergy MiCOM P139 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P439.678.700 Easergy MiCOM P439 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P539.678.700 Easergy MiCOM P539 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P632.678.700 Easergy MiCOM P632 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P633.678.700 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P634.680.701 Easergy MiCOM P634 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P633.680.701 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version P138.677.701 Easergy MiCOM P138 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version C434.679.700 Easergy MiCOM C434 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix HUe Firmware version 11.06.31 includes a fix for this vulnerability and is available for download here: . Contact Schneider Electric’s Customer Care Center to download this software. A reboot is needed to complete the firmware upgrade Vendor fix Version 6.4.610.500.101 of EPAS Gateway includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this software Vendor fix Version 3.0.4 of EPAS-UI includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this software. Vendor fix EPO 2022 CU 7 of EcoStruxure™ Power Operation includes a fix for this vulnerability and is available for download here: • https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2022-CU7-is-Now-Available/tdp/524787 Reboot needed: yes https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787 Vendor fix EPO 2024 CU 3 of EcoStruxure™ Power Operation includes a fix for this vulnerability and is available for download here: • https://community.se.com/t5/EcoStruxure-PowerOperation/Power-Operation-2024-CU3-is-HERE/td-p/534769 Reboot needed: yes https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769 Vendor fix Version 64.2025.0.14 of iPMFLS includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Vendor fix Version V02.503.101 of PowerLogic™ P5 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. Vendor fix Version V02.003.001 of PowerLogic™ P7 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. Vendor fix Version 2.9.5 of PowerLogic™ T300 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Vendor fix Version 11.08.03 of PowerLogic™ T500 includes a fix for this vulnerability Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Vendor fix CPU866e Firmware version 11.06.37 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade Mitigation Schneider Electric is establishing a remediation plan for all future versions of the following models of the Easergy MiCOM P30: P437 P532 P631 P634 P436 P438 P638 Future versions will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: • Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions Mitigation Schneider Electric is establishing a remediation plan for a future version of the Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L. P_ 4_ _ _ _ _ G_ _ _ _ _ M P_ 4_ _ _ _ _ H_ _ _ _ _ M P_ 4_ _ _ _ _ L _ _ _ _ _ M P_ 4_ _ _ _ _ G_ _ _ _ _ L P_ 4_ _ _ _ _ H_ _ _ _ _ L P_ 4_ _ _ _ _ L _ _ _ _ _ L A future version will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: • Ensure P40 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:• Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures. • Reduce the “Minimum inactivity period” using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions. Relevant CWE: CWE-331 Insufficient Entropy Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-05-12 Date Revision Summary 2026-05-12 1 Original Release 2026-06-18 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-132-02 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric MELSEC iQ-F Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series are affected: MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP <=1.000 (CVE-2026-8805) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F Series Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8805 An integer overflow or wraparound vulnerability exists in the EtherNet/IP function of MELSEC iQ-F Series EtherNet/IP module. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. View CVE Details Affected Products Mitsubishi Electric MELSEC iQ-F Series Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP: <=1.000 Product Status: known_affected Remediations Vendor fix Mitsubishi Electric is releasing fixed version 1.001 or later for MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP. Download the update file for the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-002_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to "13.1 IP Filter Function" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html." https://www.mitsubishielectric.com/fa/download/index.html Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Mitsubishi Electric reported this vulnerability to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-002 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-002 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP vers:all/* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. View CVE Details Affected Products Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: vers:all/* Product Status: known_affected Remediations No fix planned There are no plans to release fixed version for MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. For customers of MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf", and take the actions described there. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-003_en.pdf Mitigation For customers, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to "13.1 IP Filter Function" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html." https://www.mitsubishielectric.com/fa/download/index.html Mitigation For customers, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-440 Expected Behavior Violation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Mitsubishi Electric discovering this vulnerability Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-003 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Historian Site Edition

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00 (CVE-2025-36539) CVSS Vendor Equipment Vulnerabilities v3 7.7 Rockwell Automation Rockwell Automation FactoryTalk Historian Site Edition Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13036 An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: 11 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends the following: Mitigations and Workarounds for CVE-2025-13036: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and consider applying the available patch (BF32850) for their current version (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1157978/loc/en_US Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2025-44019 AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. Depending on the timing of the crash, data present in snapshots/write cache may be lost. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: <=11.00 Product Status: known_affected Remediations Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-248 Uncaught Exception Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N CVE-2025-36539 AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Historian SE: <=11.00 Product Status: known_affected Remediations Mitigation Mitigations and Workarounds for CVE-2025-36539 & CVE-2025-44109: Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use our security best practices and also consider the following: Monitor liveness of PI Network Manager and PI Archive Subsystem services. Set the PI Network Manager and PI Archive Subsystem services to automatically restart. Limit port 5450 access to trusted workstations and software. For a list of PI System firewall port requirements, see knowledge base article KB01162 - Firewall Port Requirements. For a starting point on PI system security best practices, see knowledge base article KB00833 - Best practices for securing your PI Server. Mitigation For more information, see Rockwell Automation Security Advisory SD1773 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html) https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1773.html Relevant CWE: CWE-248 Uncaught Exception Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Republication of Rockwell Automation Security Advisory SD1773 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AVer PTC cameras

View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External Parties Background Critical Infrastructure Sectors: Government Services and Facilities, Commercial Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-40624 Improper input validation in AVer PTC500S, PTC115, PTC500+, and PTC115+ cameras may allow a remote, unauthenticated attacker to achieve arbitrary code execution via a specially crafted web request. View CVE Details Affected Products AVer PTC cameras Vendor: AVer Product Version: AVer PTC500S: vers:all/*, AVer PTC115: vers:all/*, AVer PTC500+: vers:all/*, AVer PTC115+: vers:all/* Product Status: known_affected Remediations Mitigation AVer has provided a firmware fix to address this vulnerability; users can find it at the following location: (https://presentation.aver.com/DownloadFile.aspx?n=6617|1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&t=ServiceDownload). https://presentation.aver.com/DownloadFile.aspx?n=6617%7C1C01A887-7CDC-4C96-AD9A-11D53DE1AD71&t=ServiceDownload Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments fj016 reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit for potential addition: KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS Vendor Equipment Vulnerabilities v3 6.5 Apollo Pharmacy Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information, Missing Authorization Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: India Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-50034 An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status: known_affected Remediations Mitigation Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us. https://www.apollopharmacy.in/contact-us Mitigation CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology. https://www.cisa.gov/news-events/news/understanding-bluetooth-technology Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-52866 An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status: known_affected Remediations Mitigation Apollo Pharmacy did not respond to CISA's requests to coordinate. Users are encouraged to reach out to Apollo Pharmacy directly for more information:https://www.apollopharmacy.in/contact-us. https://www.apollopharmacy.in/contact-us Mitigation CISA recommends users follow the guidance in the Understanding Bluetooth Technology blog https://www.cisa.gov/news-events/news/understanding-bluetooth-technology. https://www.cisa.gov/news-events/news/understanding-bluetooth-technology Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AzeoTech DAQFactory

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 (CVE-2026-12390) CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion') Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 (CVE-2026-12390) CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12390 In AzeoTech DAQFactory versions 21.1 and prior, a Type Confusion vulnerability can be exploited by an attacker using specially crafted .ctl files which can result in code execution. View CVE Details Affected Products AzeoTech DAQFactory Vendor: AzeoTech Product Version: AzeoTech DAQFactory: <=21.1 Product Status: known_affected Remediations Mitigation Users are discouraged from using documents from unknown/untrusted sources. Mitigation Users are encouraged to store .ctl files in a folder only writeable by admin-level users. Mitigation Users are encouraged to operate in "Safe Mode" when loading documents that have been out of their control. Mitigation Users are encouraged to apply a document editing password to their documents. Relevant CWE: CWE-843 Access of Resource Using Incompatible Type ('Type Confusion') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Rocco Calvi (@TecR0c) of TecSecurity reported this vulnerability to CISA rgod of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EasyLogic T150 and Saitel DP

View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller…
Read full source summary
View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.31 (CVE-2026-6865) Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.36 (CVE-2026-6865) CVSS Vendor Equipment Vulnerabilities v3 7.1 Schneider Electric Schneider Electric EasyLogic T150 and Saitel DP Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-6865 CWE-22: Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal") vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing. View CVE Details Affected Products Schneider Electric EasyLogic T150 and Saitel DP Vendor: Schneider Electric Product Version: Schneider Electric Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions): vers:semver/<=11.06.31, Schneider Electric Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): vers:semver/<=11.06.36 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware (vers:semver/<=11.06.31) installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller includes a fix for this vulnerability and is available for download here: Mitigation Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes Mitigation Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware (vers:semver/<=11.06.36) installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): Version 11.06.37 of Saitel DP Remote Terminal Unit & Controller includes a fix for this vulnerability and is available for download here: Mitigation Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes Mitigation All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure strict credential controls, even for low privilege users. Mitigation Ensure isolation and credentials are in place, as per the product's security recommendations. Mitigation The following product versions have been fixed: Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller are fixed versions for CVE-2026-6865 Mitigation Firmware Version 11.06.37 installed on Saitel DP Remote Terminal Unit & Controller are fixed versions for CVE-2026-6865 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-03.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-132-03 Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 PDF Version, Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products - SEVD-2026-132-03 CSAF Version. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-132-03.json Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-12 Date Revision Summary 2026-05-12 1 Initial Publication 2026-06-18 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-132-03 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Analytics PavilionX

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker executing privileged operations. The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected: FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272) CVSS Vendor Equipment Vulnerabilities v3 7 Rockwell Automation Rockwell Automation FactoryTalk Analytics PavilionX Missing Authorization Background…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker executing privileged operations. The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected: FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272) CVSS Vendor Equipment Vulnerabilities v3 7 Rockwell Automation Rockwell Automation FactoryTalk Analytics PavilionX Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-14272 A security issue was identified in Pavilion due to improper authorization enforcement in API endpoints. This vulnerability can allow an unauthorized actor to execute privileged operations, including user/role management and other administrative actions. View CVE Details Affected Products Rockwell Automation FactoryTalk Analytics PavilionX Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Analytics PavilionX: <7.01 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users update FactoryTalk Analytics PavilionX software to version 7.01 or later. The upgrade can be downloaded from the Rockwell Automation Download Center: https://www.rockwellautomation.com/en-us/support/product/product-downloads.html https://www.rockwellautomation.com/en-us/support/product/product-downloads.html Mitigation See Rockwell Automation's SD1777 advisory for more information: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L 4.0 8.3 HIGH CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-06-16 Date Revision Summary 2026-06-16 1 Initial Republication of Rockwell Automation advisory SD1777 Legal Notice and Terms of Use
Browse saved snapshots