Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.
This page is an archived snapshot of the CISA Advisories feed collected on Jul 1, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
View CSAF Summary Successful exploitation of these vulnerabilities can allow an attacker to cause unauthorized access and exposure of sensitive information when the unauthenticated attacker accesses credentials stored within firmware or system files. The following versions of Schneider Electric EasyLogic T150 and Saitel DP RTU are affected: EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities can allow an attacker to cause unauthorized access and exposure of sensitive information when the unauthenticated attacker accesses credentials stored within firmware or system files. The following versions of Schneider Electric EasyLogic T150 and Saitel DP RTU are affected: EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller <=11.06.30 (CVE-2026-9650) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller <=11.06.31 (CVE-2026-9651) Saitel DP Remote Terminal Unit & Controller <=11.06.35 (CVE-2026-9650) Saitel DP Remote Terminal Unit & Controller <=11.06.37 (CVE-2026-9651) CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric EasyLogic T150 and Saitel DP RTU Insufficiently Protected Credentials, Incorrect Permission Assignment for Critical Resource Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-9650 CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files.With this credential an attacker could subsequently compromise the device if they have physical access to the device. View CVE Details Affected Products Schneider Electric EasyLogic T150 and Saitel DP RTU Vendor: Schneider Electric Product Version: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller: <=11.06.30, Schneider Electric Saitel DP Remote Terminal Unit & Controller: <=11.06.35 Product Status: known_affected Remediations Vendor fix Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-9650) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware (<=11.06.30) installed on Schneider Electric EasyLogic T150 Remote Terminal Unit & Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes. Vendor fix (CVE-2026-9650) Saitel DP Remote Terminal Unit & Controller Firmware (<=11.06.35) installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): Version 11.06.38 of SAITEL DP Remote Terminal Unit & Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes. Vendor fix The following product versions have been fixed: Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller are fixed versions for CVE-2026-9650 Vendor fix Firmware Version 11.06.38 installed on Saitel DP Remote Terminal Unit & Controller are fixed versions for CVE-2026-9650 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-9651 CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files. View CVE Details Affected Products Schneider Electric EasyLogic T150 and Saitel DP RTU Vendor: Schneider Electric Product Version: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller: <=11.06.31, Schneider Electric Saitel DP Remote Terminal Unit & Controller: <=11.06.37 Product Status: known_affected Remediations Vendor fix (CVE-2026-9651) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware (<=11.06.31) installed on Schneider Electric EasyLogic T150 Remote Terminal Unit & Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes. Vendor fix (CVE-2026-9651) Saitel DP Remote Terminal Unit & Controller Firmware (<=11.06.37) installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions): Version 11.06.38 of SAITEL DP Remote Terminal Unit & Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes. Vendor fix Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller are fixed versions for CVE-2026-9651 Vendor fix Firmware Version 11.06.38 installed on Saitel DP Remote Terminal Unit & Controller are fixed versions for CVE-2026-9651 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-160-02.json Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.4 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N 4.0 6.7 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Dick Brooks of Business Cyber Guardian reported this vulnerability to Schneider Electric. (CVE-2026-9650) Internal Researcher of Schneider Electric reported this vulnerability to CISA. (CVE-2026-9651) Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Initial Publication 2026-06-30 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-160-02 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes. The following versions of OFFIS DCMTK Toolkit are affected: DCMTK <=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628) CVSS Vendor Equipment Vulnerabilities v3 9.8 OFFIS OFFIS…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes. The following versions of OFFIS DCMTK Toolkit are affected: DCMTK <=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628) CVSS Vendor Equipment Vulnerabilities v3 9.8 OFFIS OFFIS DCMTK Toolkit Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Missing Release of Memory after Effective Lifetime, Access of Resource Using Incompatible Type ('Type Confusion') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50003 A malicious or compromised server can make a DCMTK client using bit-preserving C-GET storage mode write files outside the chosen output directory, using both relative (../) paths and absolute paths. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot: Vendor fix https://github.com/DCMTK/dcmtk/releases/tag/latest. https://github.com/DCMTK/dcmtk/releases/tag/latest Mitigation Users are recommended to download the latest GitHub release once it becomes available. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-50254 An unauthenticated remote attacker can repeatedly send a single crafted connection request to leak memory. Against storescp in its default single-process mode, memory grows quickly and the service is eventually killed, after which it stops accepting connections until an operator restarts it. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot: Vendor fix https://github.com/DCMTK/dcmtk/releases/tag/latest. https://github.com/DCMTK/dcmtk/releases/tag/latest Mitigation Users are recommended to download the latest GitHub release once it becomes available. Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-35505 An unauthenticated remote attacker can repeatedly send crafted connection requests to leak memory. In single-process deployments the memory grows until the service is killed and the port stops responding until restart. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot: Vendor fix https://github.com/DCMTK/dcmtk/releases/tag/latest. https://github.com/DCMTK/dcmtk/releases/tag/latest Mitigation Users are recommended to download the latest GitHub release once it becomes available. Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-52868 An unauthenticated attacker can read worklist records from a directory outside the intended per-AE worklist storage area. In a multi-area deployment, this can cross departmental or clinic data separation. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot: Vendor fix https://github.com/DCMTK/dcmtk/releases/tag/latest. https://github.com/DCMTK/dcmtk/releases/tag/latest Mitigation Users are recommended to download the latest GitHub release once it becomes available. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N 4.0 8.8 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-44628 An unauthenticated attacker can crash the worklist server with a single crafted query when the server has a valid Called AE Title / storage directory, the expected lockfile, and at least one matching worklist record. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot: Vendor fix https://github.com/DCMTK/dcmtk/releases/tag/latest. https://github.com/DCMTK/dcmtk/releases/tag/latest Mitigation Users are recommended to download the latest GitHub release once it becomes available. Relevant CWE: CWE-843 Access of Resource Using Incompatible Type ('Type Confusion') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Abhinav Agarwal reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager. The following versions of Mitsubishi Electric MELSOFT Update…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager. The following versions of Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M are affected: MELSOFT Update Manager SW1DND-UDM-M >=1.000A|<=1.014Q (CVE-2025-53816, CVE-2025-53817, CVE-2025-55188, CVE-2025-11001) CVSS Vendor Equipment Vulnerabilities v3 8.8 Mitsubishi Electric Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Heap-based Buffer Overflow, NULL Pointer Dereference, Improper Link Resolution Before File Access ('Link Following'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-53816 A heap-based buffer overflow vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to trigger a buffer overflow that may cause the affected product to enter a denial-of-service condition by convincing a legitimate user to decompress a specially crafted archive file using the affected product. View CVE Details Affected Products Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: >=1.000A|<=1.014Q Product Status: known_affected Remediations Mitigation Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.co.jp/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability. Mitigation For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H 4.0 5.1 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2025-53817 A NULL pointer dereference vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to trigger a NULL pointer dereference that may cause the affected product to enter a denial-of-service condition by convincing a legitimate user to decompress a specially crafted archive file using the affected product. View CVE Details Affected Products Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: >=1.000A|<=1.014Q Product Status: known_affected Remediations Mitigation Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.co.jp/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability. Mitigation For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H 4.0 5.1 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2025-55188 A link following vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to tamper with or destroy information by convincing a legitimate user to decompress a specially crafted archive file using the affected product. If the tampered or destroyed files are required for PC operation, the affected PC may enter a denial-of-service condition. View CVE Details Affected Products Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: >=1.000A|<=1.014Q Product Status: known_affected Remediations Mitigation Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.co.jp/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability. Mitigation For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Relevant CWE: CWE-59 Improper Link Resolution Before File Access ('Link Following') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.9 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:H/SA:H CVE-2025-11001 A path traversal vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to execute arbitrary code by decompressing a specially crafted archive file using the affected product. As a result, the affected product may be impacted in ways such as information theft, information tampering, a denial-of-service condition, or other impacts. View CVE Details Affected Products Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: >=1.000A|<=1.014Q Product Status: known_affected Remediations Mitigation Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.co.jp/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link "https://www.mitsubishielectric.co.jp/fa/download/index.html" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf". https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability. Mitigation For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability. Mitigation For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Mitsubishi Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Republication of Mitsubishi Electric 2026-004 Legal Notice and Terms of Use
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure. The following versions of…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure. The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected: EcoStruxure IT Data Center Expert vers:intdot/<=9.1.1, 9.1.2 (CVE-2026-8045) CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric EcoStruxure IT Data Center Expert Improper Restriction of XML External Entity Reference Background Critical Infrastructure Sectors: Information Technology, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-8045 CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints View CVE Details Affected Products Schneider Electric EcoStruxure IT Data Center Expert Vendor: Schneider Electric Product Version: EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Version 9.1.1 and Prior Product Status: fixed, known_affected Remediations Vendor fix v9.1.2 of EcoStruxure™ IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data- center-expert/#software-and-firmware https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=61851#software-and-firmware Relevant CWE: CWE-611 Improper Restriction of XML External Entity Reference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. Vincent Michel (@darkpills) of Formind Company reported this vulnerability to Schneider Electric General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-160-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Original Release 2026-06-30 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-160-01 advisory Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. The following versions of StoneFly Storage Concentrator are affected: Storage Concentrator <8.0.4.22 (CVE-2026-56415, CVE-2026-55721,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. The following versions of StoneFly Storage Concentrator are affected: Storage Concentrator <8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040) Storage Concentrator Virtual Machine <8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040) Storage Concentrator <8.0.4.26 (CVE-2026-50110) Storage Concentrator Virtual Machine <8.0.4.26 (CVE-2026-50110) Storage Concentrator <8.0.4.29 (CVE-2026-56413) Storage Concentrator Virtual Machine <8.0.4.29 (CVE-2026-56413) CVSS Vendor Equipment Vulnerabilities v3 10 StoneFly StoneFly Storage Concentrator Use of Hard-coded Credentials, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Defense Industrial Base, Energy, Financial Services, Healthcare and Public Health, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-50110 Storage Concentrator (SC & SCVM) contains hardcoded credentials for numerous internal services embedded within a configuration file. While the credentials are stored in an encoded format, the encoding can be reversed to plaintext. The exposed credentials span a broad range of internal services, including database accounts, licensing, replication services, and third-party integrations, meaning successful exploitation of this vulnerability could provide an attacker with unauthorized access to multiple interconnected systems. View CVE Details Affected Products StoneFly Storage Concentrator Vendor: StoneFly Product Version: StoneFly Storage Concentrator: <8.0.4.26, StoneFly Storage Concentrator Virtual Machine: <8.0.4.26 Product Status: known_affected Remediations Vendor fix StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities. Mitigation For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/. https://stonefly.com/contact-us/ Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.2 CRITICAL CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L 4.0 9.3 CRITICAL CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L CVE-2026-56413 Storage Concentrator (SC & SCVM) contains a command injection vulnerability in the ms_service.pl service, which listens on TCP port 9000 by default and accepts custom network packets to perform device actions. An unauthenticated remote attacker can send a specially crafted packet containing a malicious payload that is processed without adequate sanitization, resulting in arbitrary command execution with root-level privileges. View CVE Details Affected Products StoneFly Storage Concentrator Vendor: StoneFly Product Version: StoneFly Storage Concentrator: <8.0.4.29, StoneFly Storage Concentrator Virtual Machine: <8.0.4.29 Product Status: known_affected Remediations Vendor fix StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities. Mitigation For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/. https://stonefly.com/contact-us/ Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L CVE-2026-56415 Storage Concentrator (SC & SCVM) contains a command injection vulnerability within the debug.pl script that is reachable without authentication. A remote attacker can submit a specially crafted HTTP request containing a malicious payload that is processed without adequate input sanitization, resulting in arbitrary command execution with root-level privileges on the underlying system. View CVE Details Affected Products StoneFly Storage Concentrator Vendor: StoneFly Product Version: StoneFly Storage Concentrator: <8.0.4.22, StoneFly Storage Concentrator Virtual Machine: <8.0.4.22 Product Status: known_affected Remediations Vendor fix StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities. Mitigation For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/. https://stonefly.com/contact-us/ Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L CVE-2026-55721 Storage Concentrator (SC & SCVM) is vulnerable to SQL injection through cookie values processed by the login.pl and debug.pl scripts. The cookie value is incorporated directly into database queries without adequate sanitization, allowing an unauthenticated remote attacker to manipulate those queries and extract sensitive information from the underlying database, including session tokens, password hashes, and stored secret keys. View CVE Details Affected Products StoneFly Storage Concentrator Vendor: StoneFly Product Version: StoneFly Storage Concentrator: <8.0.4.22, StoneFly Storage Concentrator Virtual Machine: <8.0.4.22 Product Status: known_affected Remediations Vendor fix StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities. Mitigation For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/. https://stonefly.com/contact-us/ Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.3 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N CVE-2026-50040 Storage Concentrator (SC & SCVM) is vulnerable to reflected cross-site scripting (XSS) due to unsanitized content being echoed back in 404 error pages. An attacker can craft a malicious URL that, when visited by an authenticated user, causes arbitrary script content to execute within the victim's browser session in the context of the application. This could be leveraged to steal session cookies, redirect users, or perform unauthorized actions on behalf of the victim. View CVE Details Affected Products StoneFly Storage Concentrator Vendor: StoneFly Product Version: StoneFly Storage Concentrator: <8.0.4.22, StoneFly Storage Concentrator Virtual Machine: <8.0.4.22 Product Status: known_affected Remediations Vendor fix StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities. Mitigation For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/. https://stonefly.com/contact-us/ Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N 4.0 5.1 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:N/SA:N Acknowledgments David Yesland of Rhino Security Labs reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. The following versions of Frangoteam FUXA SCADA/HMI are affected: FUXA SCADA/HMI <=1.3.1 (CVE-2026-13207) CVSS Vendor Equipment Vulnerabilities v3 7.5 Frangoteam Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. The following versions of Frangoteam FUXA SCADA/HMI are affected: FUXA SCADA/HMI <=1.3.1 (CVE-2026-13207) CVSS Vendor Equipment Vulnerabilities v3 7.5 Frangoteam Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-13207 FUXA versions 1.3.1 and prior contain an authentication bypass vulnerability via dot-segment path normalization in the REST API. The API router fails to normalize dot-segment sequences before applying authentication middleware, allowing unauthenticated requests to access protected endpoints by prefixing paths with dot-segments such as /api/./users, /api/./roles, and /api/project/../users. These requests bypass authentication checks and return sensitive user and role data without credentials. View CVE Details Affected Products Frangoteam FUXA SCADA/HMI Vendor: Frangoteam Product Version: Frangoteam FUXA SCADA/HMI: <=1.3.1 Product Status: known_affected Remediations Mitigation Frangoteam recommends users apply the latest version of FUXA 1.3.2 or later https://github.com/frangoteam/FUXA/releases. https://github.com/frangoteam/FUXA/releases Relevant CWE: CWE-290 Authentication Bypass by Spoofing Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Joshua Hayes of Cited Relevance LLC reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data. The following versions of XZ Utils vulnerability impacting B&R Products are affected: PPC3100 <1.8.1, 1.8.1 (CVE-2025-31115) C50 <1.8.0, 1.8.0 (CVE-2025-31115) C80 <1.8.0,…
Read full source summary
View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data. The following versions of XZ Utils vulnerability impacting B&R Products are affected: PPC3100 <1.8.1, 1.8.1 (CVE-2025-31115) C50 <1.8.0, 1.8.0 (CVE-2025-31115) C80 <1.8.0, 1.8.0 (CVE-2025-31115) FT50 <1.8.1, 1.8.1 (CVE-2025-31115) MT50 <1.8.1, 1.8.1 (CVE-2025-31115) T30 <1.8.0, 1.8.0 (CVE-2025-31115) T80 <1.8.0, 1.8.0 (CVE-2025-31115) T50 <1.8.1, 1.8.1 (CVE-2025-31115) CVSS Vendor Equipment Vulnerabilities v3 7.5 B&R Industrial Automation GmbH XZ Utils vulnerability impacting B&R Products Race Condition within a Thread Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-31115 XZ Utils provide a general-purpose data-compression library plus command-line tools. In XZ Utils 5.3.3alpha to 5.8.0, the multithreaded .xz decoder in liblzma has a bug where invalid input can at least result in a crash. The effects include heap use after free and writing to an address based on the null pointer plus an offset. Applications and libraries that use the lzma_stream_decoder_mt function are affected. The bug has been fixed in XZ Utils 5.8.1, and the fix has been committed to the v5.4, v5.6, v5.8, and master branches in the xz Git repository. No new release packages will be made from the old stable branches, but a standalone patch is available that applies to all affected releases. View CVE Details Affected Products XZ Utils vulnerability impacting B&R Products Vendor: B&R Industrial Automation GmbH Product Version: B&R Industrial Automation GmbH PPC3100 <1.8.1, B&R Industrial Automation GmbH C50 <1.8.0, B&R Industrial Automation GmbH C80 <1.8.0, B&R Industrial Automation GmbH FT50 <1.8.1, B&R Industrial Automation GmbH MT50 <1.8.1, B&R Industrial Automation GmbH T30 <1.8.0, B&R Industrial Automation GmbH T80 <1.8.0, B&R Industrial Automation GmbH T50 <1.8.1 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: Product Terminal OS Version - PPC3100 1.8.1 - C50 1.8.0 - C80 1.8.0 - FT50 1.8.1 - MT50 1.8.1 - T30 1.8.0 - T80 1.8.0 - T50 1.8.1 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. Mitigation Refer to section “General security recommendations” for further advise on how to keep your system secure Relevant CWE: CWE-366 Race Condition within a Thread Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by B&R. B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently asked questions Could the vulnerability be exploited remotely? - Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had B&R received any reports that this vulnerability was being exploited? - No, B&R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT SA26P009 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-10 Date Revision Summary 2026-06-10 1 Initial version. 2026-06-30 2 Initial CISA Republication of ABB PSIRT SA26P009 advisory Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3 9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authentication for Critical Function, Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-12819 The Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions. The device accepts Modbus commands from any reachable network source without requiring credentials, privilege validation, or operator approval, allowing unauthorized read and write access to coils, holding registers, operational memory, relay states, and process control functions. View CVE Details Affected Products Delta Electronics DVP12SE PLC Vendor: Delta Electronics Product Version: Delta Electronics DVP12SE PLC: vers:all/* Product Status: known_affected Remediations Mitigation Delta Electronics is aware of these vulnerabilities and is currently working on a fix. Mitigation Delta Electronics recommends users apply the following workarounds: Mitigation Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel. Mitigation For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory. https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-12818 Delta Electronics DVP12SE PLCs are susceptible to a resource allocation vulnerability without limits or throttling (CWE-770) within their Modbus TCP service. A remote attacker could exploit this vulnerability by flooding the Modbus port (TCP/502) with a continuous stream of raw network packets or specially crafted and malformed packets. View CVE Details Affected Products Delta Electronics DVP12SE PLC Vendor: Delta Electronics Product Version: Delta Electronics DVP12SE PLC: vers:all/* Product Status: known_affected Remediations Mitigation Delta Electronics is aware of these vulnerabilities and is currently working on a fix. Mitigation Delta Electronics recommends users apply the following workarounds: Mitigation Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel. Mitigation For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory. https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Adm Bin Harbi (0xnoag) - Corvo Security reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Publication Legal Notice and Terms of Use
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations,…
Read full source summary
CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations, and samples of phishing messages.
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics DTM Soft are affected: DTMSoft vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics DTM Soft Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed:…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics DTM Soft are affected: DTMSoft vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics DTM Soft Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-12578 The affected product is vulnerable to a deserialization of untrusted data, which may allow an attacker to execute arbitrary code. View CVE Details Affected Products Delta Electronics DTM Soft Vendor: Delta Electronics Product Version: Delta Electronics DTMSoft: vers:all/* Product Status: known_affected Remediations Mitigation Delta Electronics is aware of the vulnerability and is currently working on a fix. Mitigation Delta Electronics recommends users apply the following workarounds: Mitigation Do not open unsolicited project files: Do not open or import unsolicited project files, untrusted Internet links, or unexpected attachments from emails, network shares, or USB drives. Always verify the source of the file before opening it. Mitigation Avoid running as administrator: Do not use the "Run as Administrator" option when launching the software. Running the software with standard user privileges effectively limits the damage of potential malicious code. Mitigation For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments kimiya of TrendAI Zero Day Initiative reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Republication pf Delta-PCSA-2026-00010_DT Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x DMP-8000 <v9.43.x.x CVSS Vendor Equipment Vulnerabilities v3 8.1 Daktronics Daktronics Controller Firmware Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type, Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Commercial Facilities, Information Technology, Emergency Services, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-28701 Various versions of Daktronics Controller Firmware could allow authenticated and unauthenticated remote users to escape the intended directory and enumerate arbitrary file system paths. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-33560 The DMP-5000 file service exposes authenticated arbitrary file upload functionality. There are exposed endpoints which allows authenticated users to upload files of any type without validation. No file extension filtering or content inspection is enforced which allows executable binaries and scripts to be accepted and written directly to the server. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N 4.0 8.4 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:L/SI:H/SA:N CVE-2026-31928 The DMP-5000 devices are shipped with a default administrative web account with weak authentication controls, which are not required to be changed during initial configuration or operation. Using these accounts provides full system access. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N Acknowledgments Thomas Jou of Princeton University reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12473 Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted. View CVE Details Affected Products OHIF Viewers DICOM Vendor: Open Health Imaging Foundation (OHIF) Product Version: Open Health Imaging Foundation (OHIF) OHIF DICOM Web Viewer Framework: <=v3.12.0 Product Status: known_affected Remediations Mitigation The maintainer has fixed the reported vulnerability and released version 3.12.2 (2026-05-18). The fix is located at OHIF/Viewers#5985 (master), OHIF/Viewers#5978 (release/3.12). Mitigation Users are recommended to upgrade to v3.12.2 or later. Operators who need dicomwebproxy or dicomjson in authenticated deployments must additionally configure the new dangerouslyAllowedOriginsForAuthenticatedEnvironments allowlist in app-config.js. Mitigation Users running OHIF with authentication should remove ALL unused DicomWebProxyDataSource and DicomJSONDataSource configurations from the configuration file they are deploying with. Relevant CWE: CWE-918 Server-Side Request Forgery (SSRF) Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N 4.0 8.3 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N Acknowledgments Simon Weber and Volker Schönefeld of Machine Spirits UG reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-56445 The qrscp application's C-STORE handler uses a specific instance from attacker-supplied DICOM datasets directly in os.path.join() without sanitization, allowing file writes to arbitrary paths. View CVE Details Affected Products pydicom pynetdicom Library Vendor: pydicom Product Version: pydicom pynetdicom: >=v1.0.0|<v3.0.4 Product Status: known_affected Remediations Vendor fix The maintainer of pynetdicom has not responded to requests to work with CISA to mitigate this vulnerability. For update information, refer to the github page https://github.com/pydicom/pynetdicom. https://github.com/pydicom/pynetdicom Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 4.0 8.8 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Simon Weber and Volker Schönefeld of Machine Spirits UG reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services. The following versions of Schneider Electric PowerLogic P7 are affected: PowerLogic™ P7 vers:intdot/<=0.2.003.001.000 PowerLogic™ P7 0.2.003.001.000 CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric PowerLogic P7 NULL Pointer Dereference, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Reachable Assertion Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-9716 CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-9717 CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-9718 CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.9 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H Acknowledgments Schneider Electric CPCERT reported these vulnerabilities to CISA. Cytrics reported these vulnerabilities to Schneider Electric. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment. We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries. We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-160-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Original Release 2026-06-25 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-160-03 advisory Legal Notice and Terms of Use
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01|<=R10.04 Collaborative Information Server (CI Server) >=R1.01|<=R1.04 CVSS Vendor Equipment Vulnerabilities v3 7.5 Yokogawa Yokogawa FAST/TOOLS and CI Server Cleartext Transmission of Sensitive…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01|<=R10.04 Collaborative Information Server (CI Server) >=R1.01|<=R1.04 CVSS Vendor Equipment Vulnerabilities v3 7.5 Yokogawa Yokogawa FAST/TOOLS and CI Server Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-11833 The web server may return a response containing the CI Server setting information. This information could be exploited by an attacker for other attacks. View CVE Details Affected Products Yokogawa FAST/TOOLS and CI Server Vendor: Yokogawa Product Version: Yokogawa FAST/TOOLS: >=R9.01|<=R10.04, Yokogawa Collaborative Information Server (CI Server): >=R1.01|<=R1.04 Product Status: known_affected Remediations Vendor fix Yokogawa recommends users update FAST/TOOLS up to R10.04 and apply patch software (R10.04 SP4). Mitigation Yokogawa recommends users update Collaborative Information Server (CI Server) up to R1.05. Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa security advisory report YSAR-26-0004 at: https://web-material3.yokogawa.com/1/39777/files/YSAR-26-0004-E.pdf Mitigation For questions related to this report, please contact the below. https://contact.yokogawa.com/cs/gw?c-id=000498 Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Yokogawa reported this vulnerability to JPCERT/CC Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial CISA Republication of Yokogawa Security Advisory Report YSAR-26-0004 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code. The following versions of Horner Automation Cscape are affected: Cscape <10.2_SP3 CVSS Vendor Equipment Vulnerabilities v3 7.8 Horner Automation Horner Automation Cscape Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code. The following versions of Horner Automation Cscape are affected: Cscape <10.2_SP3 CVSS Vendor Equipment Vulnerabilities v3 7.8 Horner Automation Horner Automation Cscape Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12897 Horner Automation Cscape versions prior to 10.2 SP3 are vulnerable to an Out-of-Bounds Read vulnerability through parsing CSP files. Successful exploitation of this vulnerability could allow an attacker to disclose information and execute arbitrary code. View CVE Details Affected Products Horner Automation Cscape Vendor: Horner Automation Product Version: Horner Automation Cscape: <10.2_SP3 Product Status: known_affected Remediations Vendor fix Horner Automation has released Cscape 10.2 SP3 for users to download. Vendor fix For more information, see the Cscape 10.2 SP3 release notes (https://hornerautomation.com/cscape-software-free/cscape-software/). https://hornerautomation.com/cscape-software-free/cscape-software/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Heinzl reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems Charging Station Management System Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-40702 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 9.3 CRITICAL https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-50176 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-54479 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L 4.0 6.9 MEDIUM https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N CVE-2026-44622 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N 4.0 6.9 MEDIUM https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device. The following versions of H.VIEW HV-500S6 IP Camera are affected: H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229 CVSS Vendor Equipment Vulnerabilities v3 7.2 H.VIEW H.VIEW HV-500S6 IP Camera Improper Neutralization of Special Elements used in an OS…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device. The following versions of H.VIEW HV-500S6 IP Camera are affected: H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229 CVSS Vendor Equipment Vulnerabilities v3 7.2 H.VIEW H.VIEW HV-500S6 IP Camera Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-55975 A vulnerability exists in H.View IP cameras that could allow an authenticated user to supply unsanitized XML fields to the device's certificate generation interface, which are incorporated into a backend certificate creation command without proper input validation. This may allow for command execution with elevated privileges during certificate generation. View CVE Details Affected Products H.VIEW HV-500S6 IP Camera Vendor: H.VIEW Product Version: H.VIEW H.VIEW HV-500S6 IP Camera: IPCAM_V4.06.88.251229 Product Status: known_affected Remediations Mitigation H.View did not respond to CISA's request to coordinate. Users are encouraged to reach out to H.View for support. https://hviewsmart.com/pages/contact-us https://hviewsmart.com/pages/contact-us Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H 4.0 8.6 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-56414 A vulnerability exists in H.View IP cameras certificate-related upload interfaces allow authenticated users to store arbitrary file content to fixed, persistent filesystem locations without validating file type, structure, or size. This design omission enables the placement of unexpected or malformed data in locations intended for trusted certificate material, which could affect system integrity or behavior even after reboot. View CVE Details Affected Products H.VIEW HV-500S6 IP Camera Vendor: H.VIEW Product Version: H.VIEW H.VIEW HV-500S6 IP Camera: IPCAM_V4.06.88.251229 Product Status: known_affected Remediations Mitigation H.View did not respond to CISA's request to coordinate. Users are encouraged to reach out to H.View for support. https://hviewsmart.com/pages/contact-us https://hviewsmart.com/pages/contact-us Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H 4.0 8.6 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Fukuhara Rikuto of Smooth Inc. (CTO) and Hosei University reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use