        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-02",
        "title": "CubeSpace CW0057 Reaction Wheel",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-183-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to upload arbitrary malicious firmware to the device.</strong></p>\n<p>The following versions of CubeSpace CW0057 Reaction Wheel are affected:</p>\n<ul>\n<li>CW0057 Reaction Wheel</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>CubeSpace</td>\n<td>CubeSpace CW0057 Reaction Wheel</td>\n<td>Improper Verification of Cryptographic Signature</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>South Africa</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13743</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CubeSpace CW0057 Reaction Wheel firmware versions prior to 5.0.20 are vulnerable to an Improper Verification of Cryptographic Signature vulnerability. This could allow an attacker with physical access to the product to upload arbitrary malicious firmware to the device without authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13743\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CubeSpace CW0057 Reaction Wheel</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CubeSpace</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CubeSpace CW0057 Reaction Wheel: &lt;firmware_5.0.20</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>CubeSpace has released the following firmware versions for users to enable: Firmware version 5.0.20. Firmware version 5.0.20 introduces the capability for cryptographically verified secure boot; however, this protection is not enabled by default. Users must activate signed\u2011boot functionality, particularly the fully immutable mode, to achieve full security.</p>\n<p><strong>Mitigation</strong><br>CubeSpace acknowledges the finding. The CW0057 reaction wheel authenticates firmware updates with a CRC-32 integrity check, which confirms image integrity but does not verify the source of an image. Exploitation requires direct physical access to the device and is not exploitable remotely. A device affected by this method remains recoverable: the bootloader operates independently of the application firmware and can reload known-good, CubeSpace-supplied images, so an affected unit cannot be permanently disabled by this method. Starting with firmware version 5.0.20, CubeSpace offers optional cryptographic secure boot of varying security levels which customers can enable. Given the physical-access prerequisite and the availability of recovery, CubeSpace assesses the practical risk as low.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/347.html\">CWE-347 Improper Verification of Cryptographic Signature</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>3.3</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\">CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:P</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Anthony Rose reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-02</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Jul 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Jul 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-03",
        "title": "Gardyn IoT Hub",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-183-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control IoT Hub managed devices.</strong></p>\n<p>The following versions of Gardyn IoT Hub are affected:</p>\n<ul>\n<li>Home Firmware</li>\n<li>Studio Firmware</li>\n<li>Cloud API &lt;2.12.2026 (CVE-2026-13768, CVE-2026-55726, CVE-2026-54477)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>Gardyn</td>\n<td>Gardyn IoT Hub</td>\n<td>Use of Hard-coded Credentials, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Improper Neutralization of HTTP Headers for Scripting Syntax</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Food and Agriculture</li>\n<li><strong>Countries/Areas Deployed: </strong>United States</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13768</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Gardyn devices expose a privileged iothubowner key. Access to this key will allow a malicious user to invoke an IoTHub Registry Manager function which returns connection information for all Gardyn Home Kit and Studio devices. Access to this key also allows a malicious user to execute arbitrary commands on a specific connected device and may allow the malicious user to pivot to other devices on the user's network.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13768\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Gardyn IoT Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Gardyn</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Gardyn Home Firmware: &lt;master.627, Gardyn Studio Firmware: &lt;master.627, Gardyn Cloud API: &lt;2.12.2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Gardyn states that IoT Hub deployed infrastructure has been updated to fix the listed vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>Gardyn requests that users ensure their devices have Internet connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Gardyn also recommends that users update their mobile application to the most recent version. The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App.</p>\n<p><strong>Mitigation</strong><br>Further information on Gardyn security can be found here: https://mygardyn.com/security/<br><a href=\"https://mygardyn.com/security/\">https://mygardyn.com/security/</a></p>\n<p><strong>Mitigation</strong><br>Further customer support can be obtained from Gardyn at: support@mygardyn.com<br><a href=\"mailto:support@mygardyn.com\">mailto:support@mygardyn.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.5</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-55726</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Azure Blob Storage container used for Gardyn device logs is publicly listable without authentication. A malicious user would be able to access any device log file available in the blob storage container.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-55726\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Gardyn IoT Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Gardyn</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Gardyn Home Firmware: &lt;master.627, Gardyn Studio Firmware: &lt;master.627, Gardyn Cloud API: &lt;2.12.2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Gardyn states that IoT Hub deployed infrastructure has been updated to fix the listed vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>Gardyn requests that users ensure their devices have Internet connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Gardyn also recommends that users update their mobile application to the most recent version. The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App.</p>\n<p><strong>Mitigation</strong><br>Further information on Gardyn security can be found here: https://mygardyn.com/security/<br><a href=\"https://mygardyn.com/security/\">https://mygardyn.com/security/</a></p>\n<p><strong>Mitigation</strong><br>Further customer support can be obtained from Gardyn at: support@mygardyn.com<br><a href=\"mailto:support@mygardyn.com\">mailto:support@mygardyn.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/497.html\">CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-54477</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The admin panel lacks standard security headers, enabling clickjacking and cross-site scripting attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-54477\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Gardyn IoT Hub</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Gardyn</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Gardyn Home Firmware: &lt;master.627, Gardyn Studio Firmware: &lt;master.627, Gardyn Cloud API: &lt;2.12.2026</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Gardyn states that IoT Hub deployed infrastructure has been updated to fix the listed vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>Gardyn requests that users ensure their devices have Internet connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Gardyn also recommends that users update their mobile application to the most recent version. The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App.</p>\n<p><strong>Mitigation</strong><br>Further information on Gardyn security can be found here: https://mygardyn.com/security/<br><a href=\"https://mygardyn.com/security/\">https://mygardyn.com/security/</a></p>\n<p><strong>Mitigation</strong><br>Further customer support can be obtained from Gardyn at: support@mygardyn.com<br><a href=\"mailto:support@mygardyn.com\">mailto:support@mygardyn.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/644.html\">CWE-644 Improper Neutralization of HTTP Headers for Scripting Syntax</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Michael Groberman reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-02</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Jul 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Jul 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-01",
        "title": "ST Engineering iDirect iQ-Series Terminals",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-183-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition.</strong></p>\n<p>The following versions of ST Engineering iDirect iQ-Series Terminals are affected:</p>\n<ul>\n<li>Evolution iQ\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057)</li>\n<li>3315\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057)</li>\n<li>9\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.1</td>\n<td>ST Engineering iDirect</td>\n<td>ST Engineering iDirect iQ-Series Terminals</td>\n<td>Missing Authentication for Critical Function, Cross-Site Request Forgery (CSRF)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications, Defense Industrial Base, Energy, Government Services and Facilities, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38059</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The iDirect iQ200 exposes the /api/identity and /api/ REST API endpoints without authentication. An unauthenticated attacker with network access can retrieve sensitive device information including the serial number, Device ID (DID), Terminal Private Key identifier (TPK), MAC address, and exact firmware version. The DID and TPK are used for satellite network authentication in the iDirect platform, potentially enabling terminal impersonation and network reconnaissance.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38059\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.2.2 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net/s/login.<br><a href=\"https://support.idirect.net/s/login\">https://support.idirect.net/s/login</a></p>\n<p><strong>Mitigation</strong><br>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</p>\n<p><strong>Mitigation</strong><br>Avoid exposing administrative APIs to the public internet.</p>\n<p><strong>Mitigation</strong><br>Enforce strong authentication practices.</p>\n<p><strong>Mitigation</strong><br>Monitor for anomalous API activity and unexpected device reboots.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38057</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The iDirect iQ200 does not validate CSRF tokens on state-changing API endpoints after authentication. The /api/reboot endpoint accepts POST requests authenticated solely by a session cookie that lacks the SameSite attribute. A remote attacker can host a malicious web page that, when visited by an authenticated administrator, automatically submits a cross-site POST request causing an immediate device reboot and satellite link loss. Repeated attacks can sustain a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38057\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.2.2 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net/s/login.<br><a href=\"https://support.idirect.net/s/login\">https://support.idirect.net/s/login</a></p>\n<p><strong>Mitigation</strong><br>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</p>\n<p><strong>Mitigation</strong><br>Avoid exposing administrative APIs to the public internet.</p>\n<p><strong>Mitigation</strong><br>Enforce strong authentication practices.</p>\n<p><strong>Mitigation</strong><br>Monitor for anomalous API activity and unexpected device reboots.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/352.html\">CWE-352 Cross-Site Request Forgery (CSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Ahmed Alqahtani of Aramco reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-02</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 02 Jul 26 12:00:00 +0000",
        "last_updated": "Thu, 02 Jul 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/07/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/07/01/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-45659\" target=\"_blank\">CVE-2026-45659</a> Microsoft SharePoint Server Deserialization of Untrusted Data Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 01 Jul 26 12:00:00 +0000",
        "last_updated": "Wed, 01 Jul 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-04",
        "title": "Schneider Electric EasyLogic T150 and Saitel DP RTU",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities can allow an attacker to cause unauthorized access and exposure of sensitive information when the unauthenticated attacker accesses credentials stored within firmware or system files.</strong></p>\n<p>The following versions of Schneider Electric EasyLogic T150 and Saitel DP RTU are affected:</p>\n<ul>\n<li>EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller &lt;=11.06.30 (CVE-2026-9650)</li>\n<li>EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller &lt;=11.06.31 (CVE-2026-9651)</li>\n<li>Saitel DP Remote Terminal Unit &amp; Controller &lt;=11.06.35 (CVE-2026-9650)</li>\n<li>Saitel DP Remote Terminal Unit &amp; Controller &lt;=11.06.37 (CVE-2026-9651)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EasyLogic T150 and Saitel DP RTU</td>\n<td>Insufficiently Protected Credentials, Incorrect Permission Assignment for Critical Resource</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9650</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files.With this credential an attacker could subsequently compromise the device if they have physical access to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9650\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EasyLogic T150 and Saitel DP RTU</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller: &lt;=11.06.30, Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller: &lt;=11.06.35</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-9650) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller Firmware (&lt;=11.06.30) installed on Schneider Electric EasyLogic T150 Remote Terminal Unit &amp; Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes.</p>\n<p><strong>Vendor fix</strong><br>(CVE-2026-9650) Saitel DP Remote Terminal Unit &amp; Controller Firmware (&lt;=11.06.35) installed on Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller (All versions): Version 11.06.38 of SAITEL DP Remote Terminal Unit &amp; Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes.</p>\n<p><strong>Vendor fix</strong><br>The following product versions have been fixed: Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-9650</p>\n<p><strong>Vendor fix</strong><br>Firmware Version 11.06.38 installed on Saitel DP Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-9650</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json).<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json).<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9651</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9651\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EasyLogic T150 and Saitel DP RTU</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller: &lt;=11.06.31, Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller: &lt;=11.06.37</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>(CVE-2026-9651) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller Firmware (&lt;=11.06.31) installed on Schneider Electric EasyLogic T150 Remote Terminal Unit &amp; Controller (All versions): Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes.</p>\n<p><strong>Vendor fix</strong><br>(CVE-2026-9651) Saitel DP Remote Terminal Unit &amp; Controller Firmware (&lt;=11.06.37) installed on Schneider Electric Saitel DP Remote Terminal Unit &amp; Controller (All versions): Version 11.06.38 of SAITEL DP Remote Terminal Unit &amp; Controller includes a fix for these vulnerabilities and is available: Contact Schneider Electric's Customer Care Center to download this firmware. Reboot needed: Yes.</p>\n<p><strong>Vendor fix</strong><br>Firmware Version 11.06.32 installed on EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-9651</p>\n<p><strong>Vendor fix</strong><br>Firmware Version 11.06.38 installed on Saitel DP Remote Terminal Unit &amp; Controller are fixed versions for CVE-2026-9651</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json).<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-160-02 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-160-02.pdf).CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json).<br><a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json\">https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-160-02.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/732.html\">CWE-732 Incorrect Permission Assignment for Critical Resource</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Dick Brooks of Business Cyber Guardian reported this vulnerability to Schneider Electric. (CVE-2026-9650)</li>\n<li>Internal Researcher of Schneider Electric reported this vulnerability to CISA. (CVE-2026-9651)</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-30</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-160-02</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-01",
        "title": "Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager.</strong></p>\n<p>The following versions of Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M are affected:</p>\n<ul>\n<li>MELSOFT Update Manager SW1DND-UDM-M &gt;=1.000A|&lt;=1.014Q (CVE-2025-53816, CVE-2025-53817, CVE-2025-55188, CVE-2025-11001)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M</td>\n<td>Heap-based Buffer Overflow, NULL Pointer Dereference, Improper Link Resolution Before File Access ('Link Following'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-53816</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A heap-based buffer overflow vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to trigger a buffer overflow that may cause the affected product to enter a denial-of-service condition by convincing a legitimate user to decompress a specially crafted archive file using the affected product.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-53816\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: &gt;=1.000A|&lt;=1.014Q</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/fa/download/index.html\">https://www.mitsubishielectric.co.jp/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf.<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/122.html\">CWE-122 Heap-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-53817</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A NULL pointer dereference vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to trigger a NULL pointer dereference that may cause the affected product to enter a denial-of-service condition by convincing a legitimate user to decompress a specially crafted archive file using the affected product.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-53817\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: &gt;=1.000A|&lt;=1.014Q</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/fa/download/index.html\">https://www.mitsubishielectric.co.jp/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf.<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-55188</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A link following vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to tamper with or destroy information by convincing a legitimate user to decompress a specially crafted archive file using the affected product. If the tampered or destroyed files are required for PC operation, the affected PC may enter a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-55188\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: &gt;=1.000A|&lt;=1.014Q</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/fa/download/index.html\">https://www.mitsubishielectric.co.jp/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf.<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/59.html\">CWE-59 Improper Link Resolution Before File Access ('Link Following')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.9</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:H/SA:H\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-11001</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A path traversal vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M. This vulnerability could allow a local attacker to execute arbitrary code by decompressing a specially crafted archive file using the affected product. As a result, the affected product may be impacted in ways such as information theft, information tampering, a denial-of-service condition, or other impacts.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-11001\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M: &gt;=1.000A|&lt;=1.014Q</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Mitsubishi Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:</p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.co.jp/fa/download/index.html\">https://www.mitsubishielectric.co.jp/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.015R or later for MELSOFT Update Manager SW1DND-UDM-M. Please download the update file for the fixed version from the link \"https://www.mitsubishielectric.co.jp/fa/download/index.html\" (This site is in Japanese) and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using the PC with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), or similar network security controls to prevent unauthorized access and allow only trusted users to remote login when internet access is required, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the PC with the affected product and the network to which the PC is connected, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends preventing users from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For users who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on the PC with the affected product, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For more information see the associated Mitsubishi Electric security advisory 2026-004: https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf.<br><a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-004_en.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-30</td>\n<td>1</td>\n<td>Initial Republication of Mitsubishi Electric 2026-004</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-181-01",
        "title": "OFFIS DCMTK Toolkit",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-181-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-181-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes.</strong></p>\n<p>The following versions of OFFIS DCMTK Toolkit are affected:</p>\n<ul>\n<li>DCMTK &lt;=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>OFFIS</td>\n<td>OFFIS DCMTK Toolkit</td>\n<td>Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Missing Release of Memory after Effective Lifetime, Access of Resource Using Incompatible Type ('Type Confusion')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50003</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A malicious or compromised server can make a DCMTK client using bit-preserving C-GET storage mode write files outside the chosen output directory, using both relative (../) paths and absolute paths.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50003\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OFFIS DCMTK Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OFFIS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OFFIS DCMTK: &lt;=3.7.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot:</p>\n<p><strong>Vendor fix</strong><br>https://github.com/DCMTK/dcmtk/releases/tag/latest.<br><a href=\"https://github.com/DCMTK/dcmtk/releases/tag/latest\">https://github.com/DCMTK/dcmtk/releases/tag/latest</a></p>\n<p><strong>Mitigation</strong><br>Users are recommended to download the latest GitHub release once it becomes available.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50254</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can repeatedly send a single crafted connection request to leak memory. Against storescp in its default single-process mode, memory grows quickly and the service is eventually killed, after which it stops accepting connections until an operator restarts it.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50254\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OFFIS DCMTK Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OFFIS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OFFIS DCMTK: &lt;=3.7.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot:</p>\n<p><strong>Vendor fix</strong><br>https://github.com/DCMTK/dcmtk/releases/tag/latest.<br><a href=\"https://github.com/DCMTK/dcmtk/releases/tag/latest\">https://github.com/DCMTK/dcmtk/releases/tag/latest</a></p>\n<p><strong>Mitigation</strong><br>Users are recommended to download the latest GitHub release once it becomes available.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-35505</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated remote attacker can repeatedly send crafted connection requests to leak memory. In single-process deployments the memory grows until the service is killed and the port stops responding until restart.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-35505\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OFFIS DCMTK Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OFFIS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OFFIS DCMTK: &lt;=3.7.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot:</p>\n<p><strong>Vendor fix</strong><br>https://github.com/DCMTK/dcmtk/releases/tag/latest.<br><a href=\"https://github.com/DCMTK/dcmtk/releases/tag/latest\">https://github.com/DCMTK/dcmtk/releases/tag/latest</a></p>\n<p><strong>Mitigation</strong><br>Users are recommended to download the latest GitHub release once it becomes available.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/401.html\">CWE-401 Missing Release of Memory after Effective Lifetime</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-52868</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated attacker can read worklist records from a directory outside the intended per-AE worklist storage area. In a multi-area deployment, this can cross departmental or clinic data separation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-52868\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OFFIS DCMTK Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OFFIS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OFFIS DCMTK: &lt;=3.7.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot:</p>\n<p><strong>Vendor fix</strong><br>https://github.com/DCMTK/dcmtk/releases/tag/latest.<br><a href=\"https://github.com/DCMTK/dcmtk/releases/tag/latest\">https://github.com/DCMTK/dcmtk/releases/tag/latest</a></p>\n<p><strong>Mitigation</strong><br>Users are recommended to download the latest GitHub release once it becomes available.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-44628</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An unauthenticated attacker can crash the worklist server with a single crafted query when the server has a valid Called AE Title / storage directory, the expected lockfile, and at least one matching worklist record.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-44628\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OFFIS DCMTK Toolkit</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OFFIS</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OFFIS DCMTK: &lt;=3.7.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer was notified of these vulnerabilities and has provided a fix. The fix is included in the latest commits and can be obtained in the following snapshot:</p>\n<p><strong>Vendor fix</strong><br>https://github.com/DCMTK/dcmtk/releases/tag/latest.<br><a href=\"https://github.com/DCMTK/dcmtk/releases/tag/latest\">https://github.com/DCMTK/dcmtk/releases/tag/latest</a></p>\n<p><strong>Mitigation</strong><br>Users are recommended to download the latest GitHub release once it becomes available.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/843.html\">CWE-843 Access of Resource Using Incompatible Type ('Type Confusion')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abhinav Agarwal reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-30</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-05",
        "title": "XZ Utils vulnerability impacting B&R Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data.</strong></p>\n<p>The following versions of XZ Utils vulnerability impacting B&amp;R Products are affected:</p>\n<ul>\n<li>PPC3100 &lt;1.8.1, 1.8.1 (CVE-2025-31115)</li>\n<li>C50 &lt;1.8.0, 1.8.0 (CVE-2025-31115)</li>\n<li>C80 &lt;1.8.0, 1.8.0 (CVE-2025-31115)</li>\n<li>FT50 &lt;1.8.1, 1.8.1 (CVE-2025-31115)</li>\n<li>MT50 &lt;1.8.1, 1.8.1 (CVE-2025-31115)</li>\n<li>T30 &lt;1.8.0, 1.8.0 (CVE-2025-31115)</li>\n<li>T80 &lt;1.8.0, 1.8.0 (CVE-2025-31115)</li>\n<li>T50 &lt;1.8.1, 1.8.1 (CVE-2025-31115)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>B&amp;R Industrial Automation GmbH</td>\n<td>XZ Utils vulnerability impacting B&amp;R Products</td>\n<td>Race Condition within a Thread</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-31115</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>XZ Utils provide a general-purpose data-compression library plus command-line tools. In XZ Utils 5.3.3alpha to 5.8.0, the multithreaded .xz decoder in liblzma has a bug where invalid input can at least result in a crash. The effects include heap use after free and writing to an address based on the null pointer plus an offset. Applications and libraries that use the lzma_stream_decoder_mt function are affected. The bug has been fixed in XZ Utils 5.8.1, and the fix has been committed to the v5.4, v5.6, v5.8, and master branches in the xz Git repository. No new release packages will be made from the old stable branches, but a standalone patch is available that applies to all affected releases.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-31115\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>XZ Utils vulnerability impacting B&amp;R Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH PPC3100 &lt;1.8.1, B&amp;R Industrial Automation GmbH C50 &lt;1.8.0, B&amp;R Industrial Automation GmbH C80 &lt;1.8.0, B&amp;R Industrial Automation GmbH FT50 &lt;1.8.1, B&amp;R Industrial Automation GmbH MT50 &lt;1.8.1, B&amp;R Industrial Automation GmbH T30 &lt;1.8.0, B&amp;R Industrial Automation GmbH T80 &lt;1.8.0, B&amp;R Industrial Automation GmbH T50 &lt;1.8.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: Product Terminal OS Version - PPC3100 1.8.1 - C50 1.8.0 - C80 1.8.0 - FT50 1.8.1 - MT50 1.8.1 - T30 1.8.0 - T80 1.8.0 - T50 1.8.1 B&amp;R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.</p>\n<p><strong>Mitigation</strong><br>Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/366.html\">CWE-366 Race Condition within a Thread</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>Could the vulnerability be exploited remotely? - Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had B&amp;R received any reports that this vulnerability was being exploited? - No, B&amp;R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA26P009 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-10</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-06-30</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT SA26P009 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-03",
        "title": "Schneider Electric EcoStruxure IT Data Center Expert",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its EcoStruxure\u2122 IT Data Center Expert. The EcoStruxure\u2122 IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure.</strong></p>\n<p>The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected:</p>\n<ul>\n<li>EcoStruxure IT Data Center Expert vers:intdot/&lt;=9.1.1, 9.1.2 (CVE-2026-8045)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric EcoStruxure IT Data Center Expert</td>\n<td>Improper Restriction of XML External Entity Reference</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Information Technology, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-8045</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-8045\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric EcoStruxure IT Data Center Expert</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Version 9.1.1 and Prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>v9.1.2 of EcoStruxure\u2122 IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data- center-expert/#software-and-firmware<br><a href=\"https://www.se.com/ww/en/product-country-selector/?pageType=product-range&amp;sourceId=61851#software-and-firmware\">https://www.se.com/ww/en/product-country-selector/?pageType=product-range&amp;sourceId=61851#software-and-firmware</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/611.html\">CWE-611 Improper Restriction of XML External Entity Reference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n<li>Vincent Michel (@darkpills) of Formind Company reported this vulnerability to Schneider Electric</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-160-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-06-30</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-160-01 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-06",
        "title": "StoneFly Storage Concentrator",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems.</strong></p>\n<p>The following versions of StoneFly Storage Concentrator are affected:</p>\n<ul>\n<li>Storage Concentrator &lt;8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040)</li>\n<li>Storage Concentrator Virtual Machine &lt;8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040)</li>\n<li>Storage Concentrator &lt;8.0.4.26 (CVE-2026-50110)</li>\n<li>Storage Concentrator Virtual Machine &lt;8.0.4.26 (CVE-2026-50110)</li>\n<li>Storage Concentrator &lt;8.0.4.29 (CVE-2026-56413)</li>\n<li>Storage Concentrator Virtual Machine &lt;8.0.4.29 (CVE-2026-56413)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 10</td>\n<td>StoneFly</td>\n<td>StoneFly Storage Concentrator</td>\n<td>Use of Hard-coded Credentials, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Defense Industrial Base, Energy, Financial Services, Healthcare and Public Health, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50110</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Storage Concentrator (SC &amp; SCVM) contains hardcoded credentials for numerous internal services embedded within a configuration file. While the credentials are stored in an encoded format, the encoding can be reversed to plaintext. The exposed credentials span a broad range of internal services, including database accounts, licensing, replication services, and third-party integrations, meaning successful exploitation of this vulnerability could provide an attacker with unauthorized access to multiple interconnected systems.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50110\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>StoneFly Storage Concentrator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>StoneFly</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>StoneFly Storage Concentrator: &lt;8.0.4.26, StoneFly Storage Concentrator Virtual Machine: &lt;8.0.4.26</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/.<br><a href=\"https://stonefly.com/contact-us/\">https://stonefly.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-56413</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Storage Concentrator (SC &amp; SCVM) contains a command injection vulnerability in the ms_service.pl service, which listens on TCP port 9000 by default and accepts custom network packets to perform device actions. An unauthenticated remote attacker can send a specially crafted packet containing a malicious payload that is processed without adequate sanitization, resulting in arbitrary command execution with root-level privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-56413\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>StoneFly Storage Concentrator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>StoneFly</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>StoneFly Storage Concentrator: &lt;8.0.4.29, StoneFly Storage Concentrator Virtual Machine: &lt;8.0.4.29</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/.<br><a href=\"https://stonefly.com/contact-us/\">https://stonefly.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-56415</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Storage Concentrator (SC &amp; SCVM) contains a command injection vulnerability within the debug.pl script that is reachable without authentication. A remote attacker can submit a specially crafted HTTP request containing a malicious payload that is processed without adequate input sanitization, resulting in arbitrary command execution with root-level privileges on the underlying system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-56415\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>StoneFly Storage Concentrator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>StoneFly</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>StoneFly Storage Concentrator: &lt;8.0.4.22, StoneFly Storage Concentrator Virtual Machine: &lt;8.0.4.22</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/.<br><a href=\"https://stonefly.com/contact-us/\">https://stonefly.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>10</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-55721</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Storage Concentrator (SC &amp; SCVM) is vulnerable to SQL injection through cookie values processed by the login.pl and debug.pl scripts. The cookie value is incorporated directly into database queries without adequate sanitization, allowing an unauthenticated remote attacker to manipulate those queries and extract sensitive information from the underlying database, including session tokens, password hashes, and stored secret keys.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-55721\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>StoneFly Storage Concentrator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>StoneFly</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>StoneFly Storage Concentrator: &lt;8.0.4.22, StoneFly Storage Concentrator Virtual Machine: &lt;8.0.4.22</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/.<br><a href=\"https://stonefly.com/contact-us/\">https://stonefly.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50040</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Storage Concentrator (SC &amp; SCVM) is vulnerable to reflected cross-site scripting (XSS) due to unsanitized content being echoed back in 404 error pages. An attacker can craft a malicious URL that, when visited by an authenticated user, causes arbitrary script content to execute within the victim's browser session in the context of the application. This could be leveraged to steal session cookies, redirect users, or perform unauthorized actions on behalf of the victim.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50040\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>StoneFly Storage Concentrator</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>StoneFly</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>StoneFly Storage Concentrator: &lt;8.0.4.22, StoneFly Storage Concentrator Virtual Machine: &lt;8.0.4.22</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>StoneFly recommends that users upgrade to Storage Concentrator version 8.0.4.29 or later to remediate these vulnerabilities.</p>\n<p><strong>Mitigation</strong><br>For additional questions or support, users may contact StoneFly at https://stonefly.com/contact-us/.<br><a href=\"https://stonefly.com/contact-us/\">https://stonefly.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>David Yesland of Rhino Security Labs reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-30</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-02",
        "title": "Frangoteam FUXA SCADA/HMI",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance.</strong></p>\n<p>The following versions of Frangoteam FUXA SCADA/HMI are affected:</p>\n<ul>\n<li>FUXA SCADA/HMI &lt;=1.3.1 (CVE-2026-13207)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Frangoteam</td>\n<td>Frangoteam FUXA SCADA/HMI</td>\n<td>Authentication Bypass by Spoofing</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13207</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>FUXA versions 1.3.1 and prior contain an authentication bypass vulnerability via dot-segment path normalization in the REST API. The API router fails to normalize dot-segment sequences before applying authentication middleware, allowing unauthenticated requests to access protected endpoints by prefixing paths with dot-segments such as /api/./users, /api/./roles, and /api/project/../users. These requests bypass authentication checks and return sensitive user and role data without credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13207\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Frangoteam FUXA SCADA/HMI</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Frangoteam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Frangoteam FUXA SCADA/HMI: &lt;=1.3.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Frangoteam recommends users apply the latest version of FUXA 1.3.2 or later https://github.com/frangoteam/FUXA/releases.<br><a href=\"https://github.com/frangoteam/FUXA/releases\">https://github.com/frangoteam/FUXA/releases</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/290.html\">CWE-290 Authentication Bypass by Spoofing</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Joshua Hayes of Cited Relevance LLC reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-30</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-07",
        "title": "Delta Electronics DVP12SE PLC",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-181-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-181-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement.</strong></p>\n<p>The following versions of Delta Electronics DVP12SE PLC are affected:</p>\n<ul>\n<li>DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Delta Electronics</td>\n<td>Delta Electronics DVP12SE PLC</td>\n<td>Missing Authentication for Critical Function, Allocation of Resources Without Limits or Throttling</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12819</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions. The device accepts Modbus commands from any reachable network source without requiring credentials, privilege validation, or operator approval, allowing unauthorized read and write access to coils, holding registers, operational memory, relay states, and process control functions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12819\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics DVP12SE PLC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics DVP12SE PLC: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Delta Electronics is aware of these vulnerabilities and is currently working on a fix.</p>\n<p><strong>Mitigation</strong><br>Delta Electronics recommends users apply the following workarounds:</p>\n<p><strong>Mitigation</strong><br>Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel.</p>\n<p><strong>Mitigation</strong><br>For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory.<br><a href=\"https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory\">https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12818</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Delta Electronics DVP12SE PLCs are susceptible to a resource allocation vulnerability without limits or throttling (CWE-770) within their Modbus TCP service. A remote attacker could exploit this vulnerability by flooding the Modbus port (TCP/502) with a continuous stream of raw network packets or specially crafted and malformed packets.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12818\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics DVP12SE PLC</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics DVP12SE PLC: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Delta Electronics is aware of these vulnerabilities and is currently working on a fix.</p>\n<p><strong>Mitigation</strong><br>Delta Electronics recommends users apply the following workarounds:</p>\n<p><strong>Mitigation</strong><br>Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel.</p>\n<p><strong>Mitigation</strong><br>For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory.<br><a href=\"https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory\">https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Adm Bin Harbi (0xnoag) - Corvo Security reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-30</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 30 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 30 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/29/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48558\" target=\"_blank\">CVE-2026-48558</a> SimpleHelp Authentication Bypass Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 29 Jun 26 12:00:00 +0000",
        "last_updated": "Mon, 29 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-continue-target-commercial-messaging-applications",
        "title": "Russian Intelligence Services Continue to Target Commercial Messaging Applications",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-continue-target-commercial-messaging-applications",
        "summary": "<p>CISA and the Federal Bureau of Investigation (FBI) issued an updated <a href=\"https://www.ic3.gov/PSA/2026/PSA260626\" target=\"_blank\">Public Service Announcement (PSA)</a> warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 <a href=\"https://www.cisa.gov/resources-tools/resources/russian-intelligence-services-target-commercial-messaging-application-accounts\">Russian Intelligence Services Target Commercial Messaging Application Accounts</a> and provides recent tactics, recommended mitigations, and samples of phishing messages.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 26 Jun 26 12:00:00 +0000",
        "last_updated": "Fri, 26 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-04",
        "title": "Daktronics Controller Firmware",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system.</strong></p>\n<p>The following versions of Daktronics Controller Firmware are affected:</p>\n<ul>\n<li>VFC-DMP-5000 &lt;v8.117.x.x</li>\n<li>VFC-DMP-5000 &lt;v9.43.x.x</li>\n<li>VFC-DMP-5000 &lt;v10.34.x.x</li>\n<li>DMP-5000 &lt;v10.34.x.x</li>\n<li>DMP-5000 &lt;v8.117.x.x</li>\n<li>DMP-5000 &lt;v9.43.x.x</li>\n<li>DMP-8000 &lt;v10.34.x.x</li>\n<li>DMP-8000 &lt;v8.117.x.x</li>\n<li>DMP-8000 &lt;v9.43.x.x</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.1</td>\n<td>Daktronics</td>\n<td>Daktronics Controller Firmware</td>\n<td>Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type, Use of Hard-coded Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Information Technology, Emergency Services, Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-28701</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Various versions of Daktronics Controller Firmware could allow authenticated and unauthenticated remote users to escape the intended directory and enumerate arbitrary file system paths.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-28701\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Daktronics Controller Firmware</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Daktronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Daktronics VFC-DMP-5000: &lt;v8.117.x.x, Daktronics VFC-DMP-5000: &lt;v9.43.x.x, Daktronics VFC-DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v8.117.x.x, Daktronics DMP-5000: &lt;v9.43.x.x, Daktronics DMP-8000: &lt;v10.34.x.x, Daktronics DMP-8000: &lt;v8.117.x.x, Daktronics DMP-8000: &lt;v9.43.x.x</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x</p>\n<p><strong>Mitigation</strong><br>Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-33560</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The DMP-5000 file service exposes authenticated arbitrary file upload functionality. There are exposed endpoints which allows authenticated users to upload files of any type without validation. No file extension filtering or content inspection is enforced which allows executable binaries and scripts to be accepted and written directly to the server.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-33560\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Daktronics Controller Firmware</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Daktronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Daktronics VFC-DMP-5000: &lt;v8.117.x.x, Daktronics VFC-DMP-5000: &lt;v9.43.x.x, Daktronics VFC-DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v8.117.x.x, Daktronics DMP-5000: &lt;v9.43.x.x, Daktronics DMP-8000: &lt;v10.34.x.x, Daktronics DMP-8000: &lt;v8.117.x.x, Daktronics DMP-8000: &lt;v9.43.x.x</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x</p>\n<p><strong>Mitigation</strong><br>Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:L/SI:H/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:L/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31928</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The DMP-5000 devices are shipped with a default administrative web account with weak authentication controls, which are not required to be changed during initial configuration or operation. Using these accounts provides full system access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31928\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Daktronics Controller Firmware</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Daktronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Daktronics VFC-DMP-5000: &lt;v8.117.x.x, Daktronics VFC-DMP-5000: &lt;v9.43.x.x, Daktronics VFC-DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v10.34.x.x, Daktronics DMP-5000: &lt;v8.117.x.x, Daktronics DMP-5000: &lt;v9.43.x.x, Daktronics DMP-8000: &lt;v10.34.x.x, Daktronics DMP-8000: &lt;v8.117.x.x, Daktronics DMP-8000: &lt;v9.43.x.x</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x</p>\n<p><strong>Mitigation</strong><br>Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Thomas Jou of Princeton University reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/25/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/25/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation. &nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12569\" target=\"_blank\">CVE-2026-12569</a> PTC Windchill and FlexPLM Improper Input Validation Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-20230\" target=\"_blank\">CVE-2026-20230</a> Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-06",
        "title": "Delta Electronics DTM Soft",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code.</strong></p>\n<p>The following versions of Delta Electronics DTM Soft are affected:</p>\n<ul>\n<li>DTMSoft vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Delta Electronics</td>\n<td>Delta Electronics DTM Soft</td>\n<td>Deserialization of Untrusted Data</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Taiwan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12578</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is vulnerable to a deserialization of untrusted data, which may allow an attacker to execute arbitrary code.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12578\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Delta Electronics DTM Soft</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Delta Electronics</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Delta Electronics DTMSoft: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Delta Electronics is aware of the vulnerability and is currently working on a fix.</p>\n<p><strong>Mitigation</strong><br>Delta Electronics recommends users apply the following workarounds:</p>\n<p><strong>Mitigation</strong><br>Do not open unsolicited project files: Do not open or import unsolicited project files, untrusted Internet links, or unexpected attachments from emails, network shares, or USB drives. Always verify the source of the file before opening it.</p>\n<p><strong>Mitigation</strong><br>Avoid running as administrator: Do not use the \"Run as Administrator\" option when launching the software. Running the software with standard user privileges effectively limits the damage of potential malicious code.</p>\n<p><strong>Mitigation</strong><br>For more information refer to Delta Electronic's advisory page <a href=\"https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory\">https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/502.html\">CWE-502 Deserialization of Untrusted Data</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>kimiya of TrendAI Zero Day Initiative reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Republication pf Delta-PCSA-2026-00010_DT</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-176-02",
        "title": "OHIF Viewers DICOM",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-176-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-176-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link.</strong></p>\n<p>The following versions of OHIF Viewers DICOM are affected:</p>\n<ul>\n<li>OHIF DICOM Web Viewer Framework &lt;=v3.12.0</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.2</td>\n<td>Open Health Imaging Foundation (OHIF)</td>\n<td>OHIF Viewers DICOM</td>\n<td>Server-Side Request Forgery (SSRF)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12473</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12473\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OHIF Viewers DICOM</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Open Health Imaging Foundation (OHIF)</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Open Health Imaging Foundation (OHIF) OHIF DICOM Web Viewer Framework: &lt;=v3.12.0</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>The maintainer has fixed the reported vulnerability and released version 3.12.2 (2026-05-18). The fix is located at OHIF/Viewers#5985 (master), OHIF/Viewers#5978 (release/3.12).</p>\n<p><strong>Mitigation</strong><br>Users are recommended to upgrade to v3.12.2 or later. Operators who need dicomwebproxy or dicomjson in authenticated deployments must additionally configure the new dangerouslyAllowedOriginsForAuthenticatedEnvironments allowlist in app-config.js.</p>\n<p><strong>Mitigation</strong><br>Users running OHIF with authentication should remove ALL unused DicomWebProxyDataSource and DicomJSONDataSource configurations from the configuration file they are deploying with.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/918.html\">CWE-918 Server-Side Request Forgery (SSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Simon Weber and Volker Sch\u00f6nefeld of Machine Spirits UG reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-01",
        "title": "Yokogawa FAST/TOOLS and CI Server",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability may return a response containing the CI Server setting information.</strong></p>\n<p>The following versions of Yokogawa FAST/TOOLS and CI Server are affected:</p>\n<ul>\n<li>FAST/TOOLS &gt;=R9.01|&lt;=R10.04&nbsp;</li>\n<li>Collaborative Information Server (CI Server) &gt;=R1.01|&lt;=R1.04</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Yokogawa</td>\n<td>Yokogawa FAST/TOOLS and CI Server</td>\n<td>Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Food and Agriculture</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-11833</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The web server may return a response containing the CI Server setting information. This information could be exploited by an attacker for other attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-11833\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Yokogawa FAST/TOOLS and CI Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Yokogawa</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Yokogawa FAST/TOOLS: &gt;=R9.01|&lt;=R10.04, Yokogawa Collaborative Information Server (CI Server): &gt;=R1.01|&lt;=R1.04</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Yokogawa recommends users update FAST/TOOLS up to R10.04 and apply patch software (R10.04 SP4).</p>\n<p><strong>Mitigation</strong><br>Yokogawa recommends users update Collaborative Information Server (CI Server) up to R1.05.</p>\n<p><strong>Mitigation</strong><br>For more information and details on implementing these mitigations, users should see the Yokogawa security advisory report YSAR-26-0004 at: <a href=\"https://web-material3.yokogawa.com/1/39777/files/YSAR-26-0004-E.pdf\">https://web-material3.yokogawa.com/1/39777/files/YSAR-26-0004-E.pdf</a></p>\n<p><strong>Mitigation</strong><br>For questions related to this report, please contact the below.&nbsp;<br><a href=\"https://contact.yokogawa.com/cs/gw?c-id=000498\">https://contact.yokogawa.com/cs/gw?c-id=000498</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Yokogawa reported this vulnerability to JPCERT/CC</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial CISA Republication of Yokogawa Security Advisory Report YSAR-26-0004</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-176-01",
        "title": "pydicom pynetdicom Library",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-176-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-176-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths.</strong></p>\n<p>The following versions of pydicom pynetdicom Library are affected:</p>\n<ul>\n<li>pynetdicom &gt;=v1.0.0|&lt;v3.0.4</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>pydicom</td>\n<td>pydicom pynetdicom Library</td>\n<td>Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-56445</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The qrscp application's C-STORE handler uses a specific instance from attacker-supplied DICOM datasets directly in os.path.join() without sanitization, allowing file writes to arbitrary paths.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-56445\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>pydicom pynetdicom Library</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>pydicom</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>pydicom pynetdicom: &gt;=v1.0.0|&lt;v3.0.4</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The maintainer of pynetdicom has not responded to requests to work with CISA to mitigate this vulnerability. For update information, refer to the github page https://github.com/pydicom/pynetdicom.<br><a href=\"https://github.com/pydicom/pynetdicom\">https://github.com/pydicom/pynetdicom</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Simon Weber and Volker Sch\u00f6nefeld of Machine Spirits UG reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-07",
        "title": "Schneider Electric PowerLogic P7",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its PowerLogic\u2122 P7 product. The PowerLogic\u2122 P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services.</strong></p>\n<p>The following versions of Schneider Electric PowerLogic P7 are affected:</p>\n<ul>\n<li>PowerLogic\u2122 P7 vers:intdot/&lt;=0.2.003.001.000</li>\n<li>PowerLogic\u2122 P7 0.2.003.001.000&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric PowerLogic P7</td>\n<td>NULL Pointer Dereference, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Reachable Assertion</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9716</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device\u2019s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9716\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric PowerLogic P7</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PowerLogic\u2122 P7 version 0.2.003.001.000 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. Reboot needed: Yes</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Restrict network access to P7 service endpoints (ports 8080 and 3702) \u2022 Monitor and alert on anomalous SOAP requests targeting wsApp \u2022 Limit administrative access and apply least privilege principles for all users interacting with P7.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/476.html\">CWE-476 NULL Pointer Dereference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9717</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9717\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric PowerLogic P7</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PowerLogic\u2122 P7 version 0.2.003.001.000 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. Reboot needed: Yes</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Restrict network access to P7 service endpoints (ports 8080 and 3702) \u2022 Monitor and alert on anomalous SOAP requests targeting wsApp \u2022 Limit administrative access and apply least privilege principles for all users interacting with P7.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9718</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9718\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric PowerLogic P7</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PowerLogic\u2122 P7 version 0.2.003.001.000 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. Reboot needed: Yes</p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Restrict network access to P7 service endpoints (ports 8080 and 3702) \u2022 Monitor and alert on anomalous SOAP requests targeting wsApp \u2022 Limit administrative access and apply least privilege principles for all users interacting with P7.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/617.html\">CWE-617 Reachable Assertion</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported these vulnerabilities to CISA.</li>\n<li>Cytrics reported these vulnerabilities to Schneider Electric.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment. We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries. We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-160-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-06-25</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-160-03 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-03",
        "title": "Horner Automation Cscape",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code.</strong></p>\n<p>The following versions of Horner Automation Cscape are affected:</p>\n<ul>\n<li>Cscape &lt;10.2_SP3&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Horner Automation</td>\n<td>Horner Automation Cscape</td>\n<td>Out-of-bounds Read</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12897</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Horner Automation Cscape versions prior to 10.2 SP3 are vulnerable to an Out-of-Bounds Read vulnerability through parsing CSP files. Successful exploitation of this vulnerability could allow an attacker to disclose information and execute arbitrary code.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12897\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Horner Automation Cscape</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Horner Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Horner Automation Cscape: &lt;10.2_SP3</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Horner Automation has released Cscape 10.2 SP3 for users to download.</p>\n<p><strong>Vendor fix</strong><br>For more information, see the Cscape 10.2 SP3 release notes (https://hornerautomation.com/cscape-software-free/cscape-software/).<br><a href=\"https://hornerautomation.com/cscape-software-free/cscape-software/\">https://hornerautomation.com/cscape-software-free/cscape-software/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/125.html\">CWE-125 Out-of-bounds Read</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Michael Heinzl reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-02",
        "title": "EVoke Systems Charging Station Management System",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.</strong></p>\n<p>The following versions of EVoke Systems Charging Station Management System are affected:</p>\n<ul>\n<li>EVoke CSMS vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.4</td>\n<td>EVoke Systems</td>\n<td>EVoke Systems Charging Station Management System</td>\n<td>Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-40702</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-40702\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVoke Systems Charging Station Management System</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVoke Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVoke Systems EVoke CSMS: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3.</p>\n<p><strong>Vendor fix</strong><br>EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers.</p>\n<p><strong>Mitigation</strong><br>EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns.</p>\n<p><strong>Mitigation</strong><br>EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible</p>\n<p><strong>Mitigation</strong><br>Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information.<br><a href=\"https://evokesystems.com/contact-us/\">https://evokesystems.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\">https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-50176</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-50176\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVoke Systems Charging Station Management System</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVoke Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVoke Systems EVoke CSMS: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3.</p>\n<p><strong>Vendor fix</strong><br>EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers.</p>\n<p><strong>Mitigation</strong><br>EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns.</p>\n<p><strong>Mitigation</strong><br>EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible</p>\n<p><strong>Mitigation</strong><br>Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information.<br><a href=\"https://evokesystems.com/contact-us/\">https://evokesystems.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-54479</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-54479\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVoke Systems Charging Station Management System</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVoke Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVoke Systems EVoke CSMS: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3.</p>\n<p><strong>Vendor fix</strong><br>EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers.</p>\n<p><strong>Mitigation</strong><br>EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns.</p>\n<p><strong>Mitigation</strong><br>EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible</p>\n<p><strong>Mitigation</strong><br>Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information.<br><a href=\"https://evokesystems.com/contact-us/\">https://evokesystems.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/613.html\">CWE-613 Insufficient Session Expiration</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\">https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-44622</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Charging station authentication identifiers are publicly accessible via web-based mapping platforms.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-44622\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>EVoke Systems Charging Station Management System</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>EVoke Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>EVoke Systems EVoke CSMS: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3.</p>\n<p><strong>Vendor fix</strong><br>EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers.</p>\n<p><strong>Mitigation</strong><br>EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review.</p>\n<p><strong>Mitigation</strong><br>EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns.</p>\n<p><strong>Mitigation</strong><br>EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible</p>\n<p><strong>Mitigation</strong><br>Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information.<br><a href=\"https://evokesystems.com/contact-us/\">https://evokesystems.com/contact-us/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N\">https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-05",
        "title": "H.VIEW HV-500S6 IP Camera",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device.</strong></p>\n<p>The following versions of H.VIEW HV-500S6 IP Camera are affected:</p>\n<ul>\n<li>H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.2</td>\n<td>H.VIEW</td>\n<td>H.VIEW HV-500S6 IP Camera</td>\n<td>Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unrestricted Upload of File with Dangerous Type</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-55975</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in H.View IP cameras that could allow an authenticated user to supply unsanitized XML fields to the device's certificate generation interface, which are incorporated into a backend certificate creation command without proper input validation. This may allow for command execution with elevated privileges during certificate generation.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-55975\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>H.VIEW HV-500S6 IP Camera</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>H.VIEW</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>H.VIEW H.VIEW HV-500S6 IP Camera: IPCAM_V4.06.88.251229</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>H.View did not respond to CISA's request to coordinate. Users are encouraged to reach out to H.View for support. https://hviewsmart.com/pages/contact-us<br><a href=\"https://hviewsmart.com/pages/contact-us\">https://hviewsmart.com/pages/contact-us</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-56414</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in H.View IP cameras certificate-related upload interfaces allow authenticated users to store arbitrary file content to fixed, persistent filesystem locations without validating file type, structure, or size. This design omission enables the placement of unexpected or malformed data in locations intended for trusted certificate material, which could affect system integrity or behavior even after reboot.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-56414\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>H.VIEW HV-500S6 IP Camera</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>H.VIEW</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>H.VIEW H.VIEW HV-500S6 IP Camera: IPCAM_V4.06.88.251229</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>H.View did not respond to CISA's request to coordinate. Users are encouraged to reach out to H.View for support. https://hviewsmart.com/pages/contact-us<br><a href=\"https://hviewsmart.com/pages/contact-us\">https://hviewsmart.com/pages/contact-us</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Fukuhara Rikuto of Smooth Inc. (CTO) and Hosei University reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 25 Jun 26 12:00:00 +0000",
        "last_updated": "Thu, 25 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/using-sase-modern-tic-30-solution",
        "title": "Using SASE in a Modern TIC 3.0 Solution",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/using-sase-modern-tic-30-solution",
        "summary": "<p><a class=\"c-button\" href=\"https://www.cisa.gov/sites/default/files/2026-07/The_Journey_to_Zero_Trust-Using_SAS_in_a_Modern_TIC3.0_Solution.pdf\">Using SASE in a Modern TIC 3.0 Solution</a></p>\n<p>CISA\u2019s guidance, <a href=\"https://www.cisa.gov/sites/default/files/2026-07/The_Journey_to_Zero_Trust-Using_SAS_in_a_Modern_TIC3.0_Solution.pdf\">The Journey to Zero Trust \u2013 Using Secure Access Service Edge in a Modern TIC 3.0 Solution</a>, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based architectures, advance zero trust adoption, and improve visibility and control across distributed environments will benefit from this guidance.</p>\n<p>To learn more about ZT principles, visit<a href=\"https://www.cisa.gov/topics/cybersecurity-best-practices/zero-trust\"> Zero Trust</a>. &nbsp;</p>\n<hr>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>CISA Product Survey</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/using-sase-modern-tic-30-solution\">CISA Product Survey</a></p>\n</div>\n</div>\n</div>\n<p>&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 24 Jun 26 12:00:00 +0000",
        "last_updated": "Wed, 24 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/06/23/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Four Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/06/23/cisa-adds-four-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added four new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation. &nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-67038\" target=\"_blank\">CVE-2025-67038</a> Lantronix EDS5000 Code Injection Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34908\" target=\"_blank\">CVE-2026-34908</a> Ubiquiti UniFi OS Improper Access Control Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34909\" target=\"_blank\">CVE-2026-34909</a> Ubiquiti UniFi OS Path Traversal Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-34910\" target=\"_blank\">CVE-2026-34910</a> Ubiquiti UniFi OS Improper Input Validation Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-06",
        "title": "Impact of Linux Kernel vulnerabilities on B&R products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>B&amp;R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this advisory, B&amp;R had no evidence of active exploitation targeting B&amp;R products.</strong></p>\n<p>The following versions of Impact of Linux Kernel vulnerabilities on B&amp;R products are affected:</p>\n<ul>\n<li>Linux for B&amp;R &lt;=12&nbsp;</li>\n<li>APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602</li>\n<li>X20EDS410 /all&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>B&amp;R Industrial Automation GmbH</td>\n<td>Impact of Linux Kernel vulnerabilities on B&amp;R products</td>\n<td>Incorrect Resource Transfer Between Spheres, Write-what-where Condition, Improper Privilege Management, Out-of-bounds Write, Multiple Releases of Same Resource or Handle</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31431</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: crypto: algif_aead - Revert to operating out-of-place This mostly reverts commit 72548b093ee3 except for the copying of the associated data. There is no benefit in operating in-place in algif_aead since the source and destination come from different mappings. Get rid of all the complexity added for in-place operation and just copy the AD directly.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31431\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/669.html\">CWE-669 Incorrect Resource Transfer Between Spheres</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:H/RC:C\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:H/RC:C</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-43284</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: xfrm: esp: avoid in-place decrypt on shared skb frags MSG_SPLICE_PAGES can attach pages from a pipe directly to an skb. TCP marks such skbs with SKBFL_SHARED_FRAG after skb_splice_from_iter(), so later paths that may modify packet data can first make a private copy. The IPv4/IPv6 datagram append paths did not set this flag when splicing pages into UDP skbs. That leaves an ESP-in-UDP packet made from shared pipe pages looking like an ordinary uncloned nonlinear skb. ESP input then takes the no-COW fast path for uncloned skbs without a frag_list and decrypts in place over data that is not owned privately by the skb. Mark IPv4/IPv6 datagram splice frags with SKBFL_SHARED_FRAG, matching TCP. Also make ESP input fall back to skb_cow_data() when the flag is present, so ESP does not decrypt external-ly backed frags in place. Private nonlinear skb frags still use the existing fast path. This intentionally does not change ESP output. In esp_output_head(), the path that appends the ESP trailer to existing skb tailroom without calling skb_cow_data() is not reachable for nonlinear skbs: skb_tailroom() returns zero when skb-&gt;data_len is nonzero, while ESP tailen is positive. Thus ESP output will either use the separate destination-frag path or fall back to skb_cow_data().</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-43284\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/123.html\">CWE-123 Write-what-where Condition</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46333</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: ptrace: slightly saner 'get_dumpable()' logic The 'dumpability' of a task is fundamentally about the memory image of the task - the concept comes from whether it can core dump or not - and makes no sense when you don't have an associated mm. And almost all users do in fact use it only for the case where the task has a mm pointer. But we have one odd special case: ptrace_may_access() uses 'dumpable' to check various other things entirely independently of the MM (typically explicitly using flags like PTRACE_MODE_READ_FSCREDS). Including for threads that no longer have a VM (and maybe never did, like most kernel threads). It's not what this flag was designed for, but it is what it is. The ptrace code does check that the uid/gid matches, so you do have to be uid-0 to see kernel thread details, but this means that the traditional \"drop capabilities\" model doesn't make any difference for this all. Make it all make a *bit* more sense by saying that if you don't have a MM pointer, we'll use a cached \"last dumpability\" flag if the thread ever had a MM (it will be zero for kernel threads since it is never set), and require a proper CAP_SYS_PTRACE capability to override.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46333\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/269.html\">CWE-269 Improper Privilege Management</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-46300</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: net: skbuff: preserve shared-frag marker during coalescing skb_try_coalesce() can attach paged frags from @from to @to. If @from has SKBFL_SHARED_FRAG set, the resulting @to skb can contain the same externally-owned or page-cache-backed frags, but the shared-frag marker is currently lost. That breaks the invariant relied on by later in-place writers. In particular, ESP input checks skb_has_shared_frag() before deciding whether an uncloned nonlinear skb can skip skb_cow_data(). If TCP receive coalescing has moved shared frags into an unmarked skb, ESP can see skb_has_shared_frag() as false and decrypt in place over page-cache backed frags. Propagate SKBFL_SHARED_FRAG when skb_try_coalesce() transfers paged frags. The tailroom copy path does not need the marker because it copies bytes into @to's linear data rather than transferring frag descriptors..</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-46300\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-43494</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In the Linux kernel, the following vulnerability has been resolved: net/rds: reset op_nents when zerocopy page pin fails When iov_iter_get_pages2() fails in rds_message_zcopy_from_user(), the pinned pages are released with put_page(), and rm-&gt;data.op_mmp_znotifier is cleared. But we fail to properly clear rm-&gt;data.op_nents. Later when rds_message_purge() is called from rds_sendmsg() the cleanup loop iterates over the incorrectly non zero number of op_nents and frees them again. Fix this by properly resetting op_nents when it should be in rds_message_zcopy_from_user().</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-43494\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Impact of Linux Kernel vulnerabilities on B&amp;R products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>B&amp;R Industrial Automation GmbH</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>B&amp;R Industrial Automation GmbH Linux for B&amp;R &lt;=12, B&amp;R Industrial Automation GmbH APROL &lt;APROL-AutoYaST-DVD- V4.4-010.10.260602, B&amp;R Industrial Automation GmbH X20EDS410 /all</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.</p>\n<p><strong>Mitigation</strong><br>Successful exploitation of the vulnerabilities described in this advisory requires local access to the affected system with low-privileged user credentials. Customers are strongly advised to enforce strict access control policies on all Linux-based systems, ensuring that interactive access is exclusively granted to authorized and trusted personnel. This includes reviewing and hardening user account permissions and disabling unused accounts. Refer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.</p>\n<p><strong>Workaround</strong><br>Security researchers have identified and validated the following workarounds to reduce exposure to the vulnerabilities described in this advisory. These measures do not remediate the underlying vulnerabilities but effectively block known attack vectors until patched software versions are deployed. Important: Customers are advised to thoroughly test their systems after applying any of the listed workarounds. B&amp;R has no visibility into customer-specific applications running on the underlying Linux system. It is the customer's responsibility to assess whether the applied workarounds interfere with existing application workloads prior to deployment in production environments. For Debian-based systems within an active support lifecycle, kernel patches addressing CVE-2026-31431 are already available via the official package repositories. Customers are strongly encouraged to apply these updates immediately by executing the following command: sudo apt update &amp;&amp; sudo apt upgrade A system reboot is required after the upgrade for the updated kernel to take effect. Temporary Mitigation: If an immediate system update is not feasible, the affected kernel module (algif_aead) can be disabled persistently. Security researchers have confirmed this measure effectively prevents exploitation of CVE-2026-31431. Execute the following commands as root: echo \"install algif_aead /bin/false\" &gt; /etc/modprobe.d/disable-algif.conf rmmod algif_aead 2&gt;/dev/null || true Impact assessment: Disabling the algif_aead module removes the AEAD socket interface from the kernel cryp-to API. This does not affect dm-crypt/LUKS, kTLS, IPsec/XFRM, OpenSSL, GnuTLS, NSS, or SSH. Applications explicitly configured to use the afalg engine or that directly bind aead, skcipher, or hash sockets via AF_ALG may be affected. To assess exposure prior to applying this workaround, run: lsof | grep AF_ALG</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1341.html\">CWE-1341 Multiple Releases of Same Resource or Handle</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by B&amp;R. B&amp;R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&amp;R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&amp;R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&amp;R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently asked questions</h2>\n<p>What causes the vulnerabilities? - The vulnerabilities are caused by a vulnerable Linux Kernel component. What might an attacker use the vulnerability to do? - An authenticated attacker with low privileges may elevate privileges to root. Could the vulnerabilities be exploited remotely? - Yes, an attacker with privileges to login in a vulnerable system node could exploit these vulnerabilities. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had B&amp;R received any reports that these vulnerabilities were being exploited? - B&amp;R is aware of reports indicating that these vulnerabilities had been exploited at the time this security advisory was originally issued; however, no exploitation has been observed in B&amp;R products.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT SA26P010 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-11</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Updating the CWE classification for CVE-2026-43494.</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>3</td>\n<td>Initial CISA Republication of ABB PSIRT SA26P010 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-02",
        "title": "Siemens SIPROTEC 5 Using DIGSI5 Protocol",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86 are advised to upgrade to version 10.00 or later, while the remaining models should upgrade to version 9.90 or later. These versions introduce an allow-list feature that restricts arbitrary file uploads and reduces the risk associated with this vulnerability. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens SIPROTEC 5 Using DIGSI5 Protocol are affected:</p>\n<ul>\n<li>SIPROTEC 5 6MD84 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 6MD86 (CP200) vers:all/*</li>\n<li>SIPROTEC 5 6MD86 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 6MD89 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 6MU85 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 7KE85 (CP200) vers:all/*</li>\n<li>SIPROTEC 5 7KE85 (CP300) vers:all/*</li>\n<li>SIPROTEC 5 7SA82 (CP100) vers:all/*</li>\n<li>SIPROTEC 5 7SA82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SA86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SA87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SD87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ81 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ81 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SJ86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SK85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SL86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SL87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SS85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SS85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7ST86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SX82 (CP150) vers:all/*</li>\n<li>SIPROTEC 5 7SX85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7SY82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UM85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT82 (CP100) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT82 (CP150) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT85 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT86 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT86 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7UT87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VE85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VK87 (CP200) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VK87 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 7VU85 (CP300) vers:all/*&nbsp;</li>\n<li>SIPROTEC 5 Compact 7SX800 (CP050) vers:all/*</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>Siemens</td>\n<td>Siemens SIPROTEC 5 Using DIGSI5 Protocol</td>\n<td>Unrestricted Upload of File with Dangerous Type</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-40808</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected application allows authenticated users to upload arbitrary files using DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, that could cause denial of service condition and potentially lead to code execution.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-40808\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens SIPROTEC 5 Using DIGSI5 Protocol</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP200), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP200), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5 6MU85 (CP300), SIPROTEC 5 7KE85 (CP200), SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA82 (CP100), SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SA86 (CP200), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP200), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD82 (CP100), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SD86 (CP200), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP200), SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ81 (CP100), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP100), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5 7SJ85 (CP200), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP200), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK82 (CP100), SIPROTEC 5 7SK82 (CP150), SIPROTEC 5 7SK85 (CP200), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL82 (CP100), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SL86 (CP200), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87 (CP200), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP200), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7ST85 (CP200), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT82 (CP100), SIPROTEC 5 7UT82 (CP150), SIPROTEC 5 7UT85 (CP200), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP200), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP200), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP200), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300), SIPROTEC 5 Compact 7SX800 (CP050)</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Users are advised to upgrade to V9.90 or later, which introduces an allow-list feature that restricts arbitrary file uploads</p>\n<p><strong>Mitigation</strong><br>Apply password protection to all DIGSI connections to ensure secure communication</p>\n<p><strong>Mitigation</strong><br>For DIGSI access provision your own certificates signed by your customer PKI as described in https://support.industry.siemens.com/cs/document/109768375</p>\n<p><strong>Mitigation</strong><br>For the available devices [CP050, CP100, CP150 and CP300], activate role-based access control (RBAC) in the device (supported in SIPROTEC 5 firmware versions V7.80 and higher)</p>\n<p><strong>Mitigation</strong><br>Users are advised to upgrade to V10.00 or later, which introduces an allow-list feature that restricts arbitrary file uploads</p>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>None available</strong><br>Currently no fix is available</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/434.html\">CWE-434 Unrestricted Upload of File with Dangerous Type</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-139483 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-139483 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-03",
        "title": "Siemens Products using OpenSSL",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.</strong></p>\n<p>The following versions of Siemens Products using OpenSSL are affected:</p>\n<ul>\n<li>AI Lightweight Inference Server vers:all/* (CVE-2025-15467)</li>\n<li>Connector for Azure vers:intdot/&lt;1.8.0 (CVE-2025-15467)</li>\n<li>Databus vers:intdot/&lt;3.3.2 (CVE-2025-15467)</li>\n<li>HiMed Cockpit vers:all/* (CVE-2025-15467)</li>\n<li>RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9403 (6GK5998-3GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M804PB (6GK5804-0AP00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M812-1 ADSL-Router family vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M816-1 ADSL-Router family vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-2 (6GK5874-2AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-3 (6GK5874-3AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-3 (6GK5876-3AA02-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (6GK5876-4AA10-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC622-2C (6GK5622-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC626-2C (6GK5626-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC632-2C (6GK5632-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC636-2C (6GK5636-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC642-2C (6GK5642-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE SC646-2C (6GK5646-2GS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC316-8 (6GK5324-8TS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC324-4 (6GK5328-4TS00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC332 (6GK5332-0GA00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC416-8 (6GK5424-8TR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC424-4 (6GK5428-4TR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XC432 (6GK5432-0GR00-2AC2) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR302-32 (6GK5334-5TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR322-12 (6GK5334-3TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 (6GK5334-2TS00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR502-32 (6GK5534-5TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR522-12 (6GK5534-3TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-2RR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR524-8WG (6GK5532-2SR00-3RR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-2AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-3AR3) vers:all/* (CVE-2025-15467)</li>\n<li>SCALANCE XR526-8 (6GK5534-2TR00-4AR3) vers:all/* (CVE-2025-15467)</li>\n<li>Shopfloor IT Suite vers:all/* (CVE-2025-15467)</li>\n<li>SIDIS Prime vers:intdot/&gt;=4.0.700 (CVE-2025-15467)</li>\n<li>Siemens OPC UA Modelling Editor (SiOME) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC Comfort/Mobile RT vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC HMI Basic Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC HMI Comfort Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC HMI Mobile Panels vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC IOT2050 (6ES7647-0BA00-1YA2) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC BX-21A vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC MD-57A vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC IPC ORCLA vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC PDM V9.3 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA00) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA10) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA20) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-0DA30) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA10) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA20) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC RTLS Locating Manager (6GT2780-1EA30) vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC STEP 7 V5 vers:intdot/&lt;5.7.4 (CVE-2025-15467)</li>\n<li>SIMATIC Target vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.19 vers:intdot/&lt;3.19.024 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.20 vers:intdot/&lt;3.20.012 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC OA V3.21 vers:intdot/&lt;3.21.02 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC Runtime Advanced V17 vers:intdot/&lt;17.0.9 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC Unified Sequence vers:intdot/&lt;21 (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V7.5 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V8.0 vers:all/* (CVE-2025-15467)</li>\n<li>SIMATIC WinCC V8.1 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOTION OACAMGEN (6AU1820-3EA20-0AB0) vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.1 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.2 vers:all/* (CVE-2025-15467)</li>\n<li>SIMOVE Fleetmanager V3.3 vers:all/* (CVE-2025-15467)</li>\n<li>SINAMICS G200 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS G220 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S200 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S210 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINAMICS S220 vers:intdot/&gt;=6.3 (CVE-2025-15467)</li>\n<li>SINEC INS vers:intdot/&lt;1.0.2.5 (CVE-2025-15467)</li>\n<li>SINEC NMS vers:all/* (CVE-2025-15467)</li>\n<li>SINEC Security Monitor vers:all/* (CVE-2025-15467)</li>\n<li>SINUMERIK Access MyMachine /OPC UA vers:all/* (CVE-2025-15467)</li>\n<li>SIPLANT vers:all/* (CVE-2025-15467)</li>\n<li>SITRANS ASM IQ vers:all/* (CVE-2025-15467)</li>\n<li>SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ) vers:all/* (CVE-2025-15467)</li>\n<li>User Management Component (UMC) vers:intdot/&lt;2.15.3.0 (CVE-2025-15467)</li>\n<li>Visual Inspection Cockpit vers:all/* (CVE-2025-15467)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Siemens</td>\n<td>Siemens Products using OpenSSL</td>\n<td>Out-of-bounds Write</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-15467</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Issue summary: Parsing CMS AuthEnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow. Impact summary: A stack buffer overflow may lead to a crash, causing Denial of Service, or potentially remote code execution. When parsing CMS AuthEnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before any authentication or tag verification occurs. Applications and services that parse untrusted CMS or PKCS#7 content using AEAD ciphers (e.g., S/MIME AuthEnvelopedData with AES-GCM) are vulnerable. Because the overflow occurs prior to authentication, no valid key material is required to trigger it. While exploitability to remote code execution depends on platform and toolchain mitigations, the stack-based write primitive represents a severe risk. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-15467\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Products using OpenSSL</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AI Lightweight Inference Server, Connector for Azure, Databus, HiMed Cockpit, RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE LPE9403 (6GK5998-3GS00-2AC2), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router family, SCALANCE M816-1 ADSL-Router family, SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SCALANCE XC316-8 (6GK5324-8TS00-2AC2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2), SCALANCE XC332 (6GK5332-0GA00-2AC2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2), SCALANCE XC432 (6GK5432-0GR00-2AC2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3), SCALANCE XR302-32 (6GK5334-5TS00-3AR3), SCALANCE XR302-32 (6GK5334-5TS00-4AR3), SCALANCE XR322-12 (6GK5334-3TS00-2AR3), SCALANCE XR322-12 (6GK5334-3TS00-3AR3), SCALANCE XR322-12 (6GK5334-3TS00-4AR3), SCALANCE XR326-8 (6GK5334-2TS00-2AR3), SCALANCE XR326-8 (6GK5334-2TS00-3AR3), SCALANCE XR326-8 (6GK5334-2TS00-4AR3), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3), SCALANCE XR502-32 (6GK5534-5TR00-2AR3), SCALANCE XR502-32 (6GK5534-5TR00-3AR3), SCALANCE XR502-32 (6GK5534-5TR00-4AR3), SCALANCE XR522-12 (6GK5534-3TR00-2AR3), SCALANCE XR522-12 (6GK5534-3TR00-3AR3), SCALANCE XR522-12 (6GK5534-3TR00-4AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2AR3), SCALANCE XR524-8WG (6GK5532-2SR00-2RR3), SCALANCE XR524-8WG (6GK5532-2SR00-3AR3), SCALANCE XR524-8WG (6GK5532-2SR00-3RR3), SCALANCE XR526-8 (6GK5534-2TR00-2AR3), SCALANCE XR526-8 (6GK5534-2TR00-3AR3), SCALANCE XR526-8 (6GK5534-2TR00-4AR3), Shopfloor IT Suite, SIDIS Prime, Siemens OPC UA Modelling Editor (SiOME), SIMATIC Comfort/Mobile RT, SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8), SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8), SIMATIC HMI Basic Panels, SIMATIC HMI Comfort Panels, SIMATIC HMI Mobile Panels, SIMATIC IOT2050 (6ES7647-0BA00-1YA2), SIMATIC IPC BX-21A, SIMATIC IPC MD-57A, SIMATIC IPC ORCLA, SIMATIC PDM V9.3, SIMATIC RTLS Locating Manager (6GT2780-0DA00), SIMATIC RTLS Locating Manager (6GT2780-0DA10), SIMATIC RTLS Locating Manager (6GT2780-0DA20), SIMATIC RTLS Locating Manager (6GT2780-0DA30), SIMATIC RTLS Locating Manager (6GT2780-1EA10), SIMATIC RTLS Locating Manager (6GT2780-1EA20), SIMATIC RTLS Locating Manager (6GT2780-1EA30), SIMATIC STEP 7 V5, SIMATIC Target, SIMATIC WinCC OA V3.19, SIMATIC WinCC OA V3.20, SIMATIC WinCC OA V3.21, SIMATIC WinCC Runtime Advanced V17, SIMATIC WinCC Unified Sequence, SIMATIC WinCC V7.5, SIMATIC WinCC V8.0, SIMATIC WinCC V8.1, SIMOTION OACAMGEN (6AU1820-3EA20-0AB0), SIMOVE Fleetmanager V3.1, SIMOVE Fleetmanager V3.2, SIMOVE Fleetmanager V3.3, SINAMICS G200, SINAMICS G220, SINAMICS S200, SINAMICS S210, SINAMICS S220, SINEC INS, SINEC NMS, SINEC Security Monitor, SINUMERIK Access MyMachine /OPC UA, SIPLANT, SITRANS ASM IQ, SITRANS Soft Sensor Engine IQ (SITRANS SSE IQ), User Management Component (UMC), Visual Inspection Cockpit</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>As a defense-in-depth measure, organizations may review whether affected systems are exposed to untrusted CMS/PKCS#7 content from external sources.</p>\n<p><strong>Mitigation</strong><br>Do not accept files from untrusted and unvalidated sources in the affected applications</p>\n<p><strong>Mitigation</strong><br>Restrict the port at the host with the DeviceConnectionProxy to secure destinations</p>\n<p><strong>Mitigation</strong><br>Securing the connected email server as follows: \u2022 Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. \u2022 Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). \u2022 Ensure strong authentication to access the email server. \u2022 Keep the email server software and underlying operating system up to date with the latest security patches.</p>\n<p><strong>Mitigation</strong><br>Securing the connected email server as follows: \u2022 Configure the email server to enforce encrypted communication (TLS/SSL) for all SMTP connections. \u2022 Restrict access to the email server to trusted systems only (e.g., by using firewall rules or IP allowlists). \u2022 Ensure strong authentication to access the email server. \u2022 Keep the email server software and underlying operating system up to date with the latest security patches.</p>\n<p><strong>Mitigation</strong><br>The hardening instructions mentioned in the products security concept should be followed</p>\n<p><strong>No fix planned</strong><br>Currently no fix is planned</p>\n<p><strong>None available</strong><br>Currently no fix is available</p>\n<p><strong>Vendor fix</strong><br>Update to V1.0 SP2 Update 5 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109999722/\">https://support.industry.siemens.com/cs/ww/en/view/109999722/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V1.8.0 or later version<br><a href=\"https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html\">https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17 Update 9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109800912/\">https://support.industry.siemens.com/cs/ww/en/view/109800912/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17.9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109825750/\">https://support.industry.siemens.com/cs/ww/en/view/109825750/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V17 Update 9 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109825750/\">https://support.industry.siemens.com/cs/ww/en/view/109825750/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2.15.3.0 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000730/\">https://support.industry.siemens.com/cs/ww/en/view/110000730/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V21 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109996963/\">https://support.industry.siemens.com/cs/ww/en/view/109996963/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.19 P024 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000400/\">https://support.industry.siemens.com/cs/ww/en/view/110000400/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.20 P012 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000657/\">https://support.industry.siemens.com/cs/ww/en/view/110000657/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.21 P02 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/110000985/\">https://support.industry.siemens.com/cs/ww/en/view/110000985/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V3.3.2 or later version<br><a href=\"https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html\">https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html</a></p>\n<p><strong>Vendor fix</strong><br>Update to V5.7 SP4 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109991080/\">https://support.industry.siemens.com/cs/ww/en/view/109991080/</a></p>\n<p><strong>Vendor fix</strong><br>Contact customer support siplant-support.de@siemens.com</p>\n<p><strong>Vendor fix</strong><br>Contact customer support</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT SSA-434797 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-09</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-09</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-434797 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-05",
        "title": "ABB Freelance Security Lock",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-174-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-174-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions.</strong></p>\n<p>The following versions of ABB Freelance Security Lock are affected:</p>\n<ul>\n<li>ABB System Version (&lt;=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n<li>ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions) vers:all/*&nbsp;</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.6</td>\n<td>ABB</td>\n<td>ABB Freelance Security Lock</td>\n<td>Authentication Bypass by Primary Weakness</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-7064</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker is able to attack Freelance user management when Security Lock is enabled. The precondition is that the attacker bypasses Freelance Operations which blocks access to the Windows operating system. This bypass can be achieved via undocumented or special key combinations available on modern keyboards. These combinations may allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-7064\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Freelance Security Lock</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB ABB System Version (&lt;=Freelance 2013) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions): vers:all/*, ABB ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch), CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json).<br><a href=\"https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch\">https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch</a></p>\n<p><strong>Mitigation</strong><br>For more information see the associated ABB PSIRT security advisory 7PAA020361 PDF Version (https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch)&nbsp;</p>\n<p>CSAF Version (https://psirt.abb.com/csaf/2026/7paa020361.json).<br><a href=\"https://psirt.abb.com/csaf/2026/7paa020361.json\">https://psirt.abb.com/csaf/2026/7paa020361.json</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/305.html\">CWE-305 Authentication Bypass by Primary Weakness</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Gergely Regweld Szini reported this vulnerability to ABB</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-10</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-23</td>\n<td>2</td>\n<td>Initial Republication of ABB PSIRT 7PAA020361</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 23 Jun 26 12:00:00 +0000",
        "last_updated": "Tue, 23 Jun 26 12:00:00 +0000"
    }
]