· CISA Cybersecurity Advisory

Delta Electronics DVP12SE PLC

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3 9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authentication for Critical Function, Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-12819 The Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions. The device accepts Modbus commands from any reachable network source without requiring credentials, privilege validation, or operator approval, allowing unauthorized read and write access to coils, holding registers, operational memory, relay states, and process control functions. View CVE Details Affected Products Delta Electronics DVP12SE PLC Vendor: Delta Electronics Product Version: Delta Electronics DVP12SE PLC: vers:all/* Product Status: known_affected Remediations Mitigation Delta Electronics is aware of these vulnerabilities and is currently working on a fix. Mitigation Delta Electronics recommends users apply the following workarounds: Mitigation Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel. Mitigation For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory. https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-12818 Delta Electronics DVP12SE PLCs are susceptible to a resource allocation vulnerability without limits or throttling (CWE-770) within their Modbus TCP service. A remote attacker could exploit this vulnerability by flooding the Modbus port (TCP/502) with a continuous stream of raw network packets or specially crafted and malformed packets. View CVE Details Affected Products Delta Electronics DVP12SE PLC Vendor: Delta Electronics Product Version: Delta Electronics DVP12SE PLC: vers:all/* Product Status: known_affected Remediations Mitigation Delta Electronics is aware of these vulnerabilities and is currently working on a fix. Mitigation Delta Electronics recommends users apply the following workarounds: Mitigation Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel. Mitigation For more information refer to Delta Electronic's advisory page https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory. https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Adm Bin Harbi (0xnoag) - Corvo Security reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Russian Intelligence Services Continue to Target Commercial Messaging Applications

CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations,…
Read full source summary
CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations, and samples of phishing messages.
· CISA Cybersecurity Advisory

Yokogawa FAST/TOOLS and CI Server

View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01|<=R10.04 Collaborative Information Server (CI Server) >=R1.01|<=R1.04 CVSS Vendor Equipment Vulnerabilities v3 7.5 Yokogawa Yokogawa FAST/TOOLS and CI Server Cleartext Transmission of Sensitive…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01|<=R10.04 Collaborative Information Server (CI Server) >=R1.01|<=R1.04 CVSS Vendor Equipment Vulnerabilities v3 7.5 Yokogawa Yokogawa FAST/TOOLS and CI Server Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-11833 The web server may return a response containing the CI Server setting information. This information could be exploited by an attacker for other attacks. View CVE Details Affected Products Yokogawa FAST/TOOLS and CI Server Vendor: Yokogawa Product Version: Yokogawa FAST/TOOLS: >=R9.01|<=R10.04, Yokogawa Collaborative Information Server (CI Server): >=R1.01|<=R1.04 Product Status: known_affected Remediations Vendor fix Yokogawa recommends users update FAST/TOOLS up to R10.04 and apply patch software (R10.04 SP4). Mitigation Yokogawa recommends users update Collaborative Information Server (CI Server) up to R1.05. Mitigation For more information and details on implementing these mitigations, users should see the Yokogawa security advisory report YSAR-26-0004 at: https://web-material3.yokogawa.com/1/39777/files/YSAR-26-0004-E.pdf Mitigation For questions related to this report, please contact the below. https://contact.yokogawa.com/cs/gw?c-id=000498 Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Yokogawa reported this vulnerability to JPCERT/CC Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial CISA Republication of Yokogawa Security Advisory Report YSAR-26-0004 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric PowerLogic P7

View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services. The following versions of Schneider Electric PowerLogic P7 are affected: PowerLogic™ P7 vers:intdot/<=0.2.003.001.000 PowerLogic™ P7 0.2.003.001.000 CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric PowerLogic P7 NULL Pointer Dereference, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Reachable Assertion Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-9716 CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-9717 CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-9718 CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service. View CVE Details Affected Products Schneider Electric PowerLogic P7 Vendor: Schneider Electric Product Version: PowerLogic™ P7 version 0.2.003.001.000 and prior Product Status: fixed, known_affected Remediations Vendor fix Version V02.004.001 of PowerLogicTM P7 includes a fix for this vulnerability and is available for download. Contact Schneider Electric’s Customer Care Center to download this firmware. Reboot needed: Yes Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Restrict network access to P7 service endpoints (ports 8080 and 3702) • Monitor and alert on anomalous SOAP requests targeting wsApp • Limit administrative access and apply least privilege principles for all users interacting with P7. Relevant CWE: CWE-617 Reachable Assertion Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.9 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H Acknowledgments Schneider Electric CPCERT reported these vulnerabilities to CISA. Cytrics reported these vulnerabilities to Schneider Electric. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment. We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries. We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-160-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-09 Date Revision Summary 2026-06-09 1 Original Release 2026-06-25 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-160-03 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

pydicom pynetdicom Library

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-56445 The qrscp application's C-STORE handler uses a specific instance from attacker-supplied DICOM datasets directly in os.path.join() without sanitization, allowing file writes to arbitrary paths. View CVE Details Affected Products pydicom pynetdicom Library Vendor: pydicom Product Version: pydicom pynetdicom: >=v1.0.0|<v3.0.4 Product Status: known_affected Remediations Vendor fix The maintainer of pynetdicom has not responded to requests to work with CISA to mitigate this vulnerability. For update information, refer to the github page https://github.com/pydicom/pynetdicom. https://github.com/pydicom/pynetdicom Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 4.0 8.8 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Simon Weber and Volker Schönefeld of Machine Spirits UG reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

OHIF Viewers DICOM

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12473 Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted. View CVE Details Affected Products OHIF Viewers DICOM Vendor: Open Health Imaging Foundation (OHIF) Product Version: Open Health Imaging Foundation (OHIF) OHIF DICOM Web Viewer Framework: <=v3.12.0 Product Status: known_affected Remediations Mitigation The maintainer has fixed the reported vulnerability and released version 3.12.2 (2026-05-18). The fix is located at OHIF/Viewers#5985 (master), OHIF/Viewers#5978 (release/3.12). Mitigation Users are recommended to upgrade to v3.12.2 or later. Operators who need dicomwebproxy or dicomjson in authenticated deployments must additionally configure the new dangerouslyAllowedOriginsForAuthenticatedEnvironments allowlist in app-config.js. Mitigation Users running OHIF with authentication should remove ALL unused DicomWebProxyDataSource and DicomJSONDataSource configurations from the configuration file they are deploying with. Relevant CWE: CWE-918 Server-Side Request Forgery (SSRF) Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N 4.0 8.3 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N Acknowledgments Simon Weber and Volker Schönefeld of Machine Spirits UG reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EVoke Systems Charging Station Management System

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems Charging Station Management System Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-40702 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 9.3 CRITICAL https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-50176 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-54479 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L 4.0 6.9 MEDIUM https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N CVE-2026-44622 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EVoke Systems Charging Station Management System Vendor: EVoke Systems Product Version: EVoke Systems EVoke CSMS: vers:all/* Product Status: known_affected Remediations Vendor fix EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0–3). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3. Vendor fix EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected. Mitigation EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers. Mitigation EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review. Mitigation EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns. Mitigation EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible Mitigation Contact EVoke using their contact page: https://evokesystems.com/contact-us/ for more information. https://evokesystems.com/contact-us/ Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N 4.0 6.9 MEDIUM https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Daktronics Controller Firmware

View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x DMP-8000 <v9.43.x.x CVSS Vendor Equipment Vulnerabilities v3 8.1 Daktronics Daktronics Controller Firmware Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type, Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Commercial Facilities, Information Technology, Emergency Services, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-28701 Various versions of Daktronics Controller Firmware could allow authenticated and unauthenticated remote users to escape the intended directory and enumerate arbitrary file system paths. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-33560 The DMP-5000 file service exposes authenticated arbitrary file upload functionality. There are exposed endpoints which allows authenticated users to upload files of any type without validation. No file extension filtering or content inspection is enforced which allows executable binaries and scripts to be accepted and written directly to the server. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N 4.0 8.4 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:N/SC:L/SI:H/SA:N CVE-2026-31928 The DMP-5000 devices are shipped with a default administrative web account with weak authentication controls, which are not required to be changed during initial configuration or operation. Using these accounts provides full system access. View CVE Details Affected Products Daktronics Controller Firmware Vendor: Daktronics Product Version: Daktronics VFC-DMP-5000: <v8.117.x.x, Daktronics VFC-DMP-5000: <v9.43.x.x, Daktronics VFC-DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v10.34.x.x, Daktronics DMP-5000: <v8.117.x.x, Daktronics DMP-5000: <v9.43.x.x, Daktronics DMP-8000: <v10.34.x.x, Daktronics DMP-8000: <v8.117.x.x, Daktronics DMP-8000: <v9.43.x.x Product Status: known_affected Remediations Mitigation Daktronics recommends users update their device software to one of the following versions (based on product configuration in use): 8.117.0.x, 9.43.0.x, or 10.34.0.x Mitigation Daktronics recommends updating the default passwords and encourages using strong, unique credentials per device. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N Acknowledgments Thomas Jou of Princeton University reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.