Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jul 17, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix are affected: CompactLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix are affected: CompactLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) ControlLogix 5570 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) GuardLogix 5570 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5380 <=V34.012 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5380 <=V35.011 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5380 <=V34.012 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5380 <=V35.011 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5480 <=V34.012 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5480 <=V35.011 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) ControlLogix 5580 <=V34.012 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) ControlLogix 5580 <=V35.011 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) GuardLogix 5580 <=V34.012 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) GuardLogix 5580 <=V35.011 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5380 Recovery Image <=1.072 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5380 Recovery Image <=1.072 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CompactLogix 5480 Recovery Image <=1.072 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) ControlLogix 5580 Recovery Image <=1.072 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) GuardLogix 5580 Recovery Image <=1.072 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) CVSS Vendor Equipment Vulnerabilities v3 8.6 Rockwell Automation Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-12011 A denial-of-service issue exists in 5370/5570 controllers. This vulnerability could potentially allow a remote user to load an invalid project, causing the device to enter a major non-recoverable fault (MNRF). View CVE Details Affected Products Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370: <=V35.015, Rockwell Automation Compact GuardLogix 5370: <=V35.015, Rockwell Automation ControlLogix 5570: <=V35.015, Rockwell Automation GuardLogix 5570: <=V35.015, Rockwell Automation CompactLogix 5380: <=V34.012, Rockwell Automation CompactLogix 5380: <=V35.011, Rockwell Automation Compact GuardLogix 5380: <=V34.012, Rockwell Automation Compact GuardLogix 5380: <=V35.011, Rockwell Automation CompactLogix 5480: <=V34.012, Rockwell Automation CompactLogix 5480: <=V35.011, Rockwell Automation ControlLogix 5580: <=V34.012, Rockwell Automation ControlLogix 5580: <=V35.011, Rockwell Automation GuardLogix 5580: <=V34.012, Rockwell Automation GuardLogix 5580: <=V35.011, Rockwell Automation CompactLogix 5380 Recovery Image: <=1.072, Rockwell Automation Compact GuardLogix 5380 Recovery Image: <=1.072, Rockwell Automation CompactLogix 5480 Recovery Image: <=1.072, Rockwell Automation ControlLogix 5580 Recovery Image: <=1.072, Rockwell Automation GuardLogix 5580 Recovery Image: <=1.072 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommend updating to the following: CompactLogix 5370: Update to V35.016, V36.011 and later Vendor fix Compact GuardLogix 5370: Update to V35.016, V36.011 and later Vendor fix ControlLogix 5570: Update to V35.016, V36.011 and later Vendor fix GuardLogix 5570: Update to V35.016, V36.011 and later Vendor fix CompactLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix Compact GuardLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5480: Update to V34.014, V35.013, V36.011 and later Vendor fix ControlLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix GuardLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix Compact GuardLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix CompactLogix 5480 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix ControlLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix GuardLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H CVE-2025-12012 A denial-of-service issue exists in 5380/5480/5580 controllers. This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to enter a major nonrecoverable fault (MNRF). View CVE Details Affected Products Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370: <=V35.015, Rockwell Automation Compact GuardLogix 5370: <=V35.015, Rockwell Automation ControlLogix 5570: <=V35.015, Rockwell Automation GuardLogix 5570: <=V35.015, Rockwell Automation CompactLogix 5380: <=V34.012, Rockwell Automation CompactLogix 5380: <=V35.011, Rockwell Automation Compact GuardLogix 5380: <=V34.012, Rockwell Automation Compact GuardLogix 5380: <=V35.011, Rockwell Automation CompactLogix 5480: <=V34.012, Rockwell Automation CompactLogix 5480: <=V35.011, Rockwell Automation ControlLogix 5580: <=V34.012, Rockwell Automation ControlLogix 5580: <=V35.011, Rockwell Automation GuardLogix 5580: <=V34.012, Rockwell Automation GuardLogix 5580: <=V35.011, Rockwell Automation CompactLogix 5380 Recovery Image: <=1.072, Rockwell Automation Compact GuardLogix 5380 Recovery Image: <=1.072, Rockwell Automation CompactLogix 5480 Recovery Image: <=1.072, Rockwell Automation ControlLogix 5580 Recovery Image: <=1.072, Rockwell Automation GuardLogix 5580 Recovery Image: <=1.072 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommend updating to the following: CompactLogix 5370: Update to V35.016, V36.011 and later Vendor fix Compact GuardLogix 5370: Update to V35.016, V36.011 and later Vendor fix ControlLogix 5570: Update to V35.016, V36.011 and later Vendor fix GuardLogix 5570: Update to V35.016, V36.011 and later Vendor fix CompactLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix Compact GuardLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5480: Update to V34.014, V35.013, V36.011 and later Vendor fix ControlLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix GuardLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix Compact GuardLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix CompactLogix 5480 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix ControlLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix GuardLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H CVE-2025-11698 A denial-of-service issue exists in 5380/5480/5580 controllers boot firmware lower than version 1.072. This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to enter a major non-recoverable fault (MNRF). View CVE Details Affected Products Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix Vendor: Rockwell Automation Product Version: Rockwell Automation CompactLogix 5370: <=V35.015, Rockwell Automation Compact GuardLogix 5370: <=V35.015, Rockwell Automation ControlLogix 5570: <=V35.015, Rockwell Automation GuardLogix 5570: <=V35.015, Rockwell Automation CompactLogix 5380: <=V34.012, Rockwell Automation CompactLogix 5380: <=V35.011, Rockwell Automation Compact GuardLogix 5380: <=V34.012, Rockwell Automation Compact GuardLogix 5380: <=V35.011, Rockwell Automation CompactLogix 5480: <=V34.012, Rockwell Automation CompactLogix 5480: <=V35.011, Rockwell Automation ControlLogix 5580: <=V34.012, Rockwell Automation ControlLogix 5580: <=V35.011, Rockwell Automation GuardLogix 5580: <=V34.012, Rockwell Automation GuardLogix 5580: <=V35.011, Rockwell Automation CompactLogix 5380 Recovery Image: <=1.072, Rockwell Automation Compact GuardLogix 5380 Recovery Image: <=1.072, Rockwell Automation CompactLogix 5480 Recovery Image: <=1.072, Rockwell Automation ControlLogix 5580 Recovery Image: <=1.072, Rockwell Automation GuardLogix 5580 Recovery Image: <=1.072 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommend updating to the following: CompactLogix 5370: Update to V35.016, V36.011 and later Vendor fix Compact GuardLogix 5370: Update to V35.016, V36.011 and later Vendor fix ControlLogix 5570: Update to V35.016, V36.011 and later Vendor fix GuardLogix 5570: Update to V35.016, V36.011 and later Vendor fix CompactLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix Compact GuardLogix 5380: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5480: Update to V34.014, V35.013, V36.011 and later Vendor fix ControlLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix GuardLogix 5580: Update to V34.014, V35.013, V36.011 and later Vendor fix CompactLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix Compact GuardLogix 5380 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix CompactLogix 5480 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix ControlLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Vendor fix GuardLogix 5580 Recovery Image: Update to boot firmware 1.072 or greater. If using V36.013, V37.011 or later, already has corrected boot firmware is installed Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SICAM 8

View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of…
Read full source summary
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/<26.20 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) SICORE Base system vers:intdot/<26.20.0 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens SICAM 8 Active Debug Code, Initialization of a Resource with an Insecure Default, Unverified Password Change Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-54798 The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2026-54799 The affected application contains a vulnerability in its firmware update mechanism's signature validation process. This could allow an attacker to install malicious firmware, leading to persistent code execution and system compromise. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-54800 The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2026-54801 The affected application contains insufficient validation of authentication credentials when processing administrative account modifications through the web API. This could allow an authenticated attacker to bypass security controls and gain unauthorized elevated privileges. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens reported these vulnerabilities to CISA. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact Siemens: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-229470 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-09 Date Revision Summary 2026-07-09 1 Publication Date 2026-07-16 2 Initial CISA Republication of Siemens SSA-229470 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SALTO ProAccess Space

View CSAF Summary Successful exploitation of this vulnerability allows an authenticated attacker to escalate privileges and access spaces outside their assigned partition, within the same Salto ProAccess Space installation or system. Exploitation requires valid authenticated operator credentials and the partition feature to be enabled; installations without partitioning are not affected. The following versions of…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability allows an authenticated attacker to escalate privileges and access spaces outside their assigned partition, within the same Salto ProAccess Space installation or system. Exploitation requires valid authenticated operator credentials and the partition feature to be enabled; installations without partitioning are not affected. The following versions of SALTO ProAccess Space are affected: ProAccess Space <6.13 (CVE-2026-11889) CVSS Vendor Equipment Vulnerabilities v3 6.5 SALTO SALTO ProAccess Space Authorization Bypass Through User-Controlled Key Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Spain Vulnerabilities Expand All + CVE-2026-11889 SALTO ProAccess Space software using the tenancy feature / logical partition is vulnerable to a privilege escalation attack that could allow an authorized attacker to access any space managed by the affected product. View CVE Details Affected Products SALTO ProAccess Space Vendor: SALTO Product Version: SALTO ProAccess Space: <6.13 Product Status: known_affected Remediations Mitigation Users of SALTO ProAccess using the tenancy feature should upgrade to version 6.13. Vendor fix To further enhance security after applying the update: 1. Operate ProAccess Space on a protected internal network and avoid exposing it directly to the Internet. 2. Restrict operator-level accounts to the minimum required and apply least-privilege principles. 3. If feasible, disable the partitioning feature and operate under a single partition. 4. When strong tenant separation is required, consider running separate Space instances (isolated environments) rather than relying solely on logical partitioning. Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Bernhard Lorenz of Limes Security reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk DataMosaix

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9292 A Stored Cross-Site Scripting security issue exists within FactoryTalk DataMosaix Private Cloud. The vulnerability stems from improper neutralization of user-supplied input within the Workflows configuration. An authenticated attacker with high privileges can inject malicious scripts that are permanently stored on the server. This vulnerability can result in the execution of malicious JavaScript when other users access the affected page, potentially allowing for account takeover, credential theft, or redirection to a malicious website. View CVE Details Affected Products Rockwell Automation FactoryTalk DataMosaix Vendor: Rockwell Automation Product Version: Rockwell Automation DataMosaix Private Cloud: <=8.02 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: DataMosaix Private Cloud versions 8.03 or later. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisory SD1787 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1787.html). https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1787.html Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N 4.0 8.4 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Republication of Rockwell Automation Security Advisory SD1787 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2,…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Improper Validation of Integrity Check Value Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9653 A denial-of-service security issue exists across all the 1756-EN2, EN3, and ENBT communication module due to improper validation of CIP Implicit Connection packets. An attacker on the network can exploit this by sending crafted packets to continuously disrupt device connections, though device connections will recover immediately after. View CVE Details Affected Products Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Vendor: Rockwell Automation Product Version: Rockwell Automation 1756-EN3: <=V12.001, Rockwell Automation 1756-EN2: <=V12.001, Rockwell Automation 1756-ENBT: V6.006 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users take the following actions: 1756-EN3: Update to V12.002 Vendor fix 1756-EN2: Update to V12.002 Vendor fix 1756-ENBT: Product is discontinued, fix is unavailable Relevant CWE: CWE-354 Improper Validation of Integrity Check Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Tyler Lentz of Idaho National Laboratory reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25089 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-39808 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-58644 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are frequent attack…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25089 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-39808 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-58644 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Rockwell Automation Arena

View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background…
Read full source summary
View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-8085 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8312 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8313 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the linker.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8314 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the siman.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Heinzl reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AutomationDirect Productivity Suite

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389, CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerabilities v3 7 AutomationDirect AutomationDirect Productivity Suite Out-of-bounds Write, Out-of-bounds Read, Divide By Zero Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-60063 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-61389 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-60140 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This can lead to exposing sensitive information or causing the affected product to become unstable or unavailable. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-57896 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This could lead to limited information disclosure or disruption of the affected product. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-60073 An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H 4.0 5.2 MEDIUM CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-61378 A divide-by-zero vulnerability in the Productivity Suite allows a local attacker to cause a division by zero leading to a system crash. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-369 Divide By Zero Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 6.8 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Luca Borzacchiello of Nozomi Networks reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Flex 5000 Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12659 A denial-of-service security issue exists in the affected products. The security issue stems from improper handling of exceptional conditions when processing crafted CIP packets sent to the adapter. A power cycle is required to recover the module and associated I/O. View CVE Details Affected Products Rockwell Automation Flex 5000 Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation Flex 5000 Adapter: 6.011 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: Flex 5000 Adapter version 6.012. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisory SD1789 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1789.html). https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1789.html Relevant CWE: CWE-415 Double Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Republication of Rockwell Automation Security Advisory SD1789 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

NASA Core Flight System (cFS) Health & Safety (HS) Application

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer Dereference Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-15352 A vulnerability exists in the Health & Safety (HS) application of NASA's Core Flight System (cFS). The flaw allows the application to crash via segmentation fault when processing a routine Housekeeping Telemetry request, leading to denial of service. View CVE Details Affected Products NASA Core Flight System (cFS) Health & Safety (HS) Application Vendor: NASA Product Version: NASA Core Flight System (cFS) Health & Safety (HS) Application: <v7.0.1 Product Status: known_affected Remediations Mitigation NASA recommends users update to v7.0.1 (https://github.com/nasa/HS/releases/tag/v7.0.1) https://github.com/nasa/HS/releases/tag/v7.0.1 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Grady DeRosa reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Establishing a Coordinated Vulnerability Disclosure Program to Work With Security Researchers

Developed by CISA, the National Security Agency (NSA) and international partners, this joint guidance contains best practices for software manufacturers and online service providers to design and implement a coordinated vulnerability disclosure (CVD) program for working with external security researchers that includes a clear vulnerability disclosure policy (VDP) and process for triaging, remediating and assigning…
Read full source summary
Developed by CISA, the National Security Agency (NSA) and international partners, this joint guidance contains best practices for software manufacturers and online service providers to design and implement a coordinated vulnerability disclosure (CVD) program for working with external security researchers that includes a clear vulnerability disclosure policy (VDP) and process for triaging, remediating and assigning Common Vulnerabilities and Exposures (CVE) identifiers to reported vulnerabilities. The guidance also provides considerations for leveraging third-party intermediaries, like CISA or other national computer security incident response teams, to substitute or supplement a CVD program. By implementing a robust CVD program aligned with this guidance, organizations can work transparently and collaboratively with security researchers to remediate vulnerabilities, build constructive relationships, enhance product security while improving vulnerability management processes, and demonstrate their dedication to protecting customers.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-4346 KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability CVE-2026-46817 Oracle E-Business Suite Improper Privilege Management Vulnerability These types of vulnerabilities are frequent attack vectors for…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-4346 KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability CVE-2026-46817 Oracle E-Business Suite Improper Privilege Management Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

ABB Advant Master Online Builder

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions. The following versions of ABB Advant Master Online Builder are affected: Control Builder A <=1.4/4 (CVE-2025-13162) 800xA for…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions. The following versions of ABB Advant Master Online Builder are affected: Control Builder A <=1.4/4 (CVE-2025-13162) 800xA for Advant Master <=6.0.3-1, <=6.1.1-1, 6.1.1-3, 6.2.0-1 (CVE-2025-13162, CVE-2025-13162, CVE-2025-13162, CVE-2025-13162) CVSS Vendor Equipment Vulnerabilities v3 4.4 ABB ABB Advant Master Online Builder Uncontrolled Search Path Element Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-13162 The application improperly handles the search path for loading DLL´s, potentially allowing unauthorized libraries from untrusted directories. An attacker who obtains the necessary access could exploit the vulnerability leading to unauthorized code execution and compromising system integrity. View CVE Details Affected Products ABB Advant Master Online Builder Vendor: ABB Product Version: ABB Control Builder A <=1.4/4, ABB 800xA for Advant Master <=6.0.3-1, ABB 800xA for Advant Master <=6.1.1-1, ABB 800xA for Advant Master 6.1.1-3, ABB 800xA for Advant Master 6.2.0-1 Product Status: known_affected Remediations Vendor fix ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later. Mitigation Since it is required that the attacker has access to the system, it is important that all users that have access to the system are managed as recommended by ABB guidelines. - Allow only authorized users to log on to the system and enforce strong passwords that are changed regularly. - Restrict temporary connection of portable computers, USB memory devices and other removable data carriers. Computers that can be physically accessed by regular users should have ports for removable data carriers disabled or at least managed to only allow intended device types. For more information on recommended practices, see [1]. Workaround The recommendation is to upgrade to a version where the vulnerability is corrected. If an upgrade Is not possible and a workaround is needed, contact ABB Support. Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What is the scope of vulnerability? - An attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node. What causes the vulnerability? - The vulnerability is caused by not having restricted permission on an application directory where DLL files are stored. What is Advant Master Online Builder? - Online Builder is part of Control Builder A, being a set of applications for configuration and programming of Advant Master controllers. Online Builder is also part of 800xA for Advant Master, an extension package to System 800xA connecting to Advant Master controllers. What might an attacker use the vulnerability to do? - An attacker who successfully exploited this vulnerability can run arbitrary code in an affected node. How could an attacker exploit the vulnerability? - An attacker who obtains the necessary access could exploit vulnerability by placing malicious DLL´s in the unrestricted application directory, leading to unauthorized code execution and compromising system integrity. Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have physical access to an affected system node. Can functional safety be affected by an exploit of this vulnerability? - No. What does the update do? - The update of the Online Builder (ONB) resolves the vulnerability by adding restrictions to the application folder, requiring authentication. When this security advisory was issued, had this vulnerability been publicly disclosed? - No, ABB identified this vulnerability through its internal security assessment and verification processes. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA020047 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-23 Date Revision Summary 2026-06-23 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 7PAA020047 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 1715-AENTR EtherNet/IP Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment Vulnerabilities v3 10 Rockwell Automation Rockwell Automation 1715-AENTR EtherNet/IP Adapter Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10577 A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. View CVE Details Affected Products Rockwell Automation 1715-AENTR EtherNet/IP Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation 1715-AENTR EtherNet/IP Adapter: <=3.003 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends that users update to 1715-AENTR EtherNet/IP Adapter version 3.011 and later. Mitigation Rockwell Automation recommends users of the affected software who are not able to upgrade to one of the corrected versions should use their security best practices. https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see the Rockwell Automation security advisory SD1785 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html Mitigation If you have any questions regarding this security issue and how to mitigate it,contact Rockwell Automation for help. https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Initial Republication of Rockwell Automation security advisory SD1785. Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems.…
Read full source summary
View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control of the system The following versions of ABB Ability Edgenius are affected: Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100, >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - E3100C, >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Server - vE1000 (CVE-2026-31431, CVE-2026-31431, CVE-2026-31431) CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Edgenius Incorrect Resource Transfer Between Spheres Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. The issue originates in the Linux kernel’s cryptographic subsystem and impacts kernels used by most major Linux distributions released since 2017. Successful exploitation requires local code execution, however, in shared, containerized, or multi‑tenant environments this may increase the security risk View CVE Details Affected Products ABB Ability Edgenius Vendor: ABB Product Version: ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100, ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - E3100C, ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Server - vE1000 Product Status: known_affected Remediations Vendor fix The problem is corrected in the following product versions: - Edgenius 3.2.4.1 ABB recommends that customers apply the update at earliest convenience. Mitigation Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Refer to section General security recommendations for further advise on how to keep your system secure. Recommended mitigation factors - Limit access to ssh or cockpit - By default, no additional lower privilege users are present on Edgenius installations Relevant CWE: CWE-669 Incorrect Resource Transfer Between Spheres Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What causes the vulnerability? - A flaw was found in the Linux kernel's algif_aead cryptographic algorithm interface. An incorrect 'in-place operation' was introduced, where the source and destination data mappings were different. This could lead to unexpected behavior or data integrity issues during cryptographic operations, potentially impacting the reliability of encrypted communications. What is Edgenius? - ABB Ability™ Edgenius is an edge computing platform that - Connects to control systems, devices, and equipment - Collects and contextualizes operational data - Hosts applications that deliver real-time insights and AI-driven recommendations What might an attacker use the vulnerability to do? - Successful exploitation could enable a local user attacker to gain administrative control of the system node, execute arbitrary code, or cause the node to become unavailable. How could an attacker exploit the vulnerability? - An attacker could exploit this vulnerability after obtaining local access to the system. By invoking the Linux kernel’s affected cryptographic interface (algif_aead), the attacker can trigger incorrect memory handling in the kernel. This allows the attacker to escalate privileges from a normal user to full administrative (root) access on the affected system node Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have local access (physical access or through valid SSH credentials) to an affected system node. What does the update do? - The update resolves the issue by incorporating the security update of the Linux kernel. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited for Edgenius when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA024620 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 7PAA024620 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Urges SharePoint Hardening After New Exploitations

Update July 16, 2026: CISA has updated this Alert to reflect the addition of CVE-2026-58644 to its Known Exploited Vulnerabilities (KEV) Catalog on July 16, 2026. CISA is aware of active exploitation of vulnerabilities CVE-2026-32201, CVE-2026-45659, CVE-2026-56164, and CVE-2026-58644, enabling cyber threat actors to gain unauthorized access to on-premises SharePoint Server instances. These vulnerabilities affect…
Read full source summary
Update July 16, 2026: CISA has updated this Alert to reflect the addition of CVE-2026-58644 to its Known Exploited Vulnerabilities (KEV) Catalog on July 16, 2026. CISA is aware of active exploitation of vulnerabilities CVE-2026-32201, CVE-2026-45659, CVE-2026-56164, and CVE-2026-58644, enabling cyber threat actors to gain unauthorized access to on-premises SharePoint Server instances. These vulnerabilities affect all supported on-premises SharePoint Server versions (Subscription Edition, 2019, and 2016) and involve establishing remote code execution (RCE) and post-exploitation activities, such as stealing Internet Information Services (IIS) machine keys and performing deserialization techniques, to gain persistence and deploy malware. Organizations should monitor affected SharePoint Servers closely for any signs of exploitation or unusual activity. Additionally, the following newly disclosed CVE is not yet known to have been exploited, but Microsoft has identified it as posing a potential risk if left unpatched: CVE-2026-55040 CISA urges organizations to detect and remediate a potential compromise by implementing the following recommendations: Apply the latest patches and security updates from Microsoft, verify that installation completes successfully, and shorten patching cycles when possible. Verify that Antimalware Scan Interface (AMSI) integration is enabled for each SharePoint web application. Follow Microsoft’s Configure AMSI integration with SharePoint Server guidance to ensure proper configuration and select the “Full Mode” option for the Request Body Scan Mode, where feasible. When compromise is expected, use the following AMSI and Microsoft Defender Antivirus (MDAV) detections, and implement your organization’s incident response plan for any positive detections: AMSI: Exploit:Script/SuspSignoutReqBody.A – request body scanning; SharePoint Server Subscription only; Microsoft has blocked observed attempts. AMSI: Exploit:Script/ToolPaneAuthBypass.A – request header scanning; SharePoint Server 2016, 2019, and Subscription Edition. AMSI: Exploit:Script/ToolPaneAuthBypass.C – RCE coverage; SharePoint Server 2016, 2019, and Subscription Edition. MDAV: Backdoor:MSIL/LeakFang.A!dha – post-exploitation activity alert involving IIS-protected secrets. In addition, CISA recommends that organizations implement the following SharePoint Server hardening measures: Before rotating IIS machine keys, hunt for and remediate any intrusion artifacts, including machine-key harvesters, that could allow for the keys to be stolen again. Review Microsoft’s Improved ASP.NET view state security and key management for best practices. Establish tailored logging mechanisms to detect and monitor exploitation activities. Review telemetry for anomalous requests, suspicious SharePoint worker-process activity, webshells, and machine-key access. For more information, see CISA’s Best Practices for Event Logging and Threat Detection. Avoid exposing SharePoint Servers directly to the internet unless necessary; and if necessary, only configure a SharePoint Server behind a Layer 7 reverse proxy or equivalent application-layer security control that requires authentication and can inspect and filter requests. Block external access to SharePoint Central Administration, restrict farm and database communications to required systems, and review Microsoft’s SharePoint Server security-hardening guidance for role-specific ports, services, and Web.config settings. CISA urges users and administrators to review the Alert UPDATE: Microsoft Releases Guidance on Exploitation of SharePoint Vulnerabilities and apply necessary updates. CISA added the following vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog: CVE-2026-32201 on April 14, 2026; CVE-2026-45659 on July 1, 2026; CVE-2026-56164 on July 14, 2026; and CVE-2026-58644 on July 16, 2026. Note: CISA may update this Alert to reflect new guidance issued by CISA or other parties. Organizations should report incidents or anomalous activity to CISA via CISA’s 24/7 Operations Center at contact@cisa.dhs.gov or 1-844-Say-CISA (1-844-729-2472). Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements Microsoft contributed to this Alert.
· CISA Cybersecurity Advisory

ABB T-MAC Plus

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways. The following versions of ABB T-MAC Plus are affected: T-MAC Plus 4.0-24 (CVE-2025-14771, CVE-2025-14772,…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways. The following versions of ABB T-MAC Plus are affected: T-MAC Plus 4.0-24 (CVE-2025-14771, CVE-2025-14772, CVE-2025-14773, CVE-2025-14774) CVSS Vendor Equipment Vulnerabilities v3 9.9 ABB ABB T-MAC Plus Files or Directories Accessible to External Parties, Authorization Bypass Through User-Controlled Key, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Incorrect Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-14771 File Disclosure in ABB T-MAC Plus web application allows authenticated users to exfiltrate files containing sensitive information via crafted HTTP GET request. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation The misconfigurations on the IIS server, which were reported to security auditing, have been corrected. File Browsing Feature was enabled on that IIS server. That feature along with the default IIS site has been removed. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-14772 Broken access controls in ABB T-MAC Plus web application allows unprivileged users to performs administrative operations View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation ABB T-MAC Plus web application supports several classes of users (e.g., Admin, Customer, Operator, etc.) with different roles. An authenticated user with low privileges (e.g., Customer) can execute administrative operations. The privileges associated to the different users have been revised and applied correctly. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-14773 Stored Cross-Site Scripting (XSS) in ABB T-MAC Plus web application allows authenticated users to execute arbitrary HTML or JavaScript code on victims browser. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation A DOM-based XSS vulnerability is present. If a malicious actor gains access to the operations network and can create or edit an existing entity, they could insert malicious JavaScript code to be executed in the web forms. New T-MAC Plus version 4.0-25 will correct the vulnerability. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2025-14774 Insecure network protocol in ABB T-MAC Plus allows unauthenticated attackers to perform a denial-of-service (DoS) of the Card Reader service. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation If a malicious actor gains physical access to a serial device, disables it, connects a malicious device with same IP address, and sends a specially crafted message, the service responsible for communicating with the device will be blocked until a manual restart is performed. New T-MAC Plus version 4.0-25 will correct the vulnerability. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H Acknowledgments Angelo Catalani of the Italian National Cybersecurity Agency (ACN) responsibly disclosed the vulnerabilities and provided valuable input on product improvements. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What causes the vulnerability? - The vulnerabilities are caused by: - Wrong configuration in T-MAC Plus IIS Server. - Wrong configuration of privileges of users. - Lack of encryption in communication protocol. What is T-MAC Plus? - T-MAC Plus is a Terminal Management System (TMS) that handles the different operations (receipt and dispatch product, access control, product movement in the tank farm, …) in a terminal. It is applicable to different type of products such as chemical and petroleum terminals, pipeline or refinery tankage, bulk plants or hydrogen terminals. The following components are affected: - TMAC Plus Web application - Communication protocol with Card Readers What might an attacker use the vulnerability to do? - An attacker who successfully exploited this vulnerability could cause the affected system node to stop or become inaccessible and allow the attacker to insert and run arbitrary code. How could an attacker exploit the vulnerability? - An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network directly. Recommended practices help mitigate such attacks, see section Mitigating Factors. Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have physical access to an affected system node. Can functional safety be affected by an exploit of this vulnerability? - While these vulnerabilities primarily impact confidentiality, integrity, and availability, they do not directly affect functional safety in the traditional sense What does the update do? - The update removes the vulnerability by modifying the way that the T-MAC Plus web application and the communication protocol are configured. When this security advisory was issued, had this vulnerability been publicly disclosed? - No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108472A7840 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-03 Date Revision Summary 2026-06-03 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 9AKK108472A7840 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-15409 SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability CVE-2026-15410 SonicWall SMA1000 Appliances Code Injection Vulnerability CVE-2026-56155 Microsoft Active Directory Federation Services Insufficient Granularity of Access Control Vulnerability…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-15409 SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability CVE-2026-15410 SonicWall SMA1000 Appliances Code Injection Vulnerability CVE-2026-56155 Microsoft Active Directory Federation Services Insufficient Granularity of Access Control Vulnerability CVE-2026-56164 Microsoft SharePoint Server Missing Authentication for Critical Function Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Improve Router Hygiene to Protect Against Russian State-Sponsored Targeting

Russian Government-Sponsored Activity Targets Poorly Configured and Vulnerable Devices Across Critical Sectors Executive summary Russian Federal Security Service (FSB) Center 16 cyber actors continue to exploit poorly configured and vulnerable networking devices worldwide, opportunistically compromising multiple critical infrastructure sector networks. This joint Cybersecurity Advisory (CSA) builds on FBI’s Russian…
Read full source summary
Russian Government-Sponsored Activity Targets Poorly Configured and Vulnerable Devices Across Critical Sectors Executive summary Russian Federal Security Service (FSB) Center 16 cyber actors continue to exploit poorly configured and vulnerable networking devices worldwide, opportunistically compromising multiple critical infrastructure sector networks. This joint Cybersecurity Advisory (CSA) builds on FBI’s Russian Government Cyber Actors Targeting Networking Devices, Critical Infrastructure Public Service Announcement of the decade-plus FSB Center 16 cyber activity by providing additional tactics, techniques, and procedures (TTPs) to enable defenders to more fully understand and counter the threat. [1] This CSA is being released by the following authoring and co-sealing agencies: United States National Security Agency (NSA) United States Cybersecurity and Infrastructure Security Agency (CISA) United States Federal Bureau of Investigation (FBI) United States Department of Defense Cyber Crime Center (DC3) Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC) Communications Security Establishment Canada’s (CSE’s) Canadian Centre for Cyber Security (Cyber Centre) New Zealand National Cyber Security Centre (NCSC-NZ) United Kingdom National Cyber Security Centre (NCSC-UK) Czech Republic National Cyber and Information Security Agency (NÚKIB)1 Danish Defence Intelligence Service (DDIS)2 Estonian Foreign Intelligence Service (EFIS)3 Estonian Information System Authority (RIA)4 Finnish Defence Intelligence (FDI)5 Finnish Security and Intelligence Service (SUPO)6 French National Cybersecurity Agency (ANSSI)7 Italian External Intelligence and Security Agency (AISE)8 Italian Internal Intelligence and Security Agency (AISI)9 The Military Counterintelligence Service of Poland (SKW)10 Sweden National Cyber Security Centre (NCSC-SE)11 The authoring and co-sealing agencies strongly urge device owners and network defenders to take mitigation and remediation actions against Russian government-sponsored exploitation of vulnerable routers. Figure 1: FSB Center 16 activity and recommended mitigation actions Download the PDF version of this report: Improve Router Hygiene to Protect Against Russian State-Sponsored Targeting (PDF, 816KB) Cybersecurity industry tracking The cybersecurity industry provides overlapping cyber threat intelligence, indicators of compromise (IOCs), and mitigation recommendations related to this activity. Although not all encompassing, the following list contains the most notable threat group names commonly used within the cybersecurity community related to this activity: Berserk Bear Energetic Bear Crouching Yeti Dragonfly Ghost Blizzard Static Tundra Note: Cybersecurity companies have different methods of tracking and attributing cyber actors, and this list may not provide a 1:1 correlation to the authoring agencies’ understanding for all activity related to these groupings. Targeting details Critical infrastructure sectors most at risk from the Russian Federal Security Service (FSB) Center 16 cyber actors’ targeting include: Communications, Defense Industrial Base, Energy, Financial Services, Government Services and Facilities, especially organizations at the state and local level, and Healthcare and Public Health. Technical details Note: This advisory uses the MITRE ATT&CK® Matrix for Enterprise12 framework, version 19. See Appendix A for tables of the activity mapped to MITRE ATT&CK tactics and techniques. This advisory also uses MITRE DEFENDTM version 1.4.0. The Russian FSB Center 16 cyber actors primarily use scanning to identify poorly configured networking devices, primarily routers, for exploitation. The actors scan for Internet IP ranges with active Simple Network Management Protocol (SNMP) agents that accept common or default community strings for authentication [T1595.001, T1595.002]. These scans, run via proxies, consist of SNMP Set-Requests from a spoofed IP address [T1027] containing Object Identifiers (OIDs) that instruct the SNMP agent on poorly configured networking devices to [T1569, T1602.001, T1090]: Copy its configuration to a file, often called “config.bkp” or “output.txt” [T1003, T1602.002]. Transfer the file, typically using Trivial File Transfer Protocol (TFTP), to an actor-controlled leased virtual private server (VPS) or compromised FTP server [T1583.003, T1090, T1071, T1048]. While SNMP scanning is the primary method the actors use to discover and exploit poorly configured networking devices, they occasionally exploit common vulnerabilities and exposures (CVEs) in Cisco devices, Cisco’s Smart Install (SMI) functionality, and web portals to manage network devices. The actors previously exploited at least the following CVEs [T1584.008, T1588.005, T1190, T1068]: CVE-2018-0171 CVE-2008-412813 Many of these TTPs overlap with activity by other malicious cyber actors, such as Salt Typhoon. Even though this CSA focuses on Russian FSB Center 16 cyber activity, the mitigations below should detect and counter these and similar TTPs used by other actors. Mitigation actions The authoring agencies highly recommend network defenders implement the following mitigations to harden networks against this exploitation: Disable Cisco Smart Install on all devices [D3-ACH]. [2] Use SNMPv3 with “authPriv” configured to the most modern encryption standard that is supported by the device instead of SNMPv1 or SNMPv2 [D3-ACH]. [3] Disable SNMPv1 and SNMPv2. These are legacy protocols and should no longer be needed on current devices. If they are necessary, change all community strings from defaults and only allow read-only community strings rather than read-write access. SNMPv3 adds strong authentication and data encryption that are unavailable in SNMPv1 and v2. SNMPv3 replaces clear text shared passwords, known as community strings, with more securely encoded parameters, and authenticates and encrypts data [D3-MAN, D3-MENCR]. Use strong, unique passwords for local accounts on network devices and configure credentials to be stored securely to prevent reuse of compromised passwords [D3-CH]. Cisco devices protect passwords in the configuration file using different hashing types. Use hashing type 8 for user credentials. Avoid using hashing type 0, 4, and 7 as they are insecure or store passwords in plaintext in the configuration file. [4] Monitor for unusual credentials that do not conform to standard organizational naming conventions [D3-PM]. Monitor for and alert on logins using local accounts. Local accounts should only be used in emergency situations when accounts supported by centralized authentication servers are unavailable. Centralized authentication to network devices should support multi-factor authentication where feasible. [3] Monitor and restrict access to SNMP OIDs using a Management Information Base (MIB) allow list [D3-ACH]. [5] Reference the vendor-specific MIB for the network devices and monitor OIDs for indications of reconnaissance or misconfiguration in logs or intrusion detection systems (IDS). IDS rules should be written for inbound SNMP Set-Requests that contain OIDs targeting sensitive device data [D3-PM]. Example OIDs include: 1.3.6.1.4.1.9.9.96.1.1 (Cisco Config Copy) 1.3.6.1.4.1.9.9.96.1.1.1.1.5 (Config Copy Server Address, value for this OID is where the configuration file is being sent to) Restrict management protocols [D3-NTF]. Use Access Control Lists (ACLs) to only allow management protocols, such as SNMP, from management devices, preferably on an out-of-band network. [3] On edge firewalls and devices deny all external communications on the following ports unless mission critical, with strict monitoring if blocking is not feasible: User Datagram Protocol (UDP) port 69 (TFTP) Transmission Control Protocol (TCP) port 4786 (SMI) UDP ports 161 and 162 (SNMP) TCP/UDP ports 10161 and 10162 (SNMPv3) Update network device software and firmware images, especially to patch known vulnerabilities, and upgrade end-of-life devices to supported ones. Use an attack surface management service to identify and secure Internet-facing systems with weak configurations and known vulnerabilities [D3-NVA]. U.S.-based federal, state, local, tribal, and territorial governments and U.S. critical infrastructure organiztions should consider signing up for CISA’s no-cost Cyber Hygiene services. U.S. Defense Industrial Base organizations should consider signing up for NSA’s DIB Cybersecurity Services. Resources United States: Russia Threat Overview and Advisories Network Infrastructure Security Guide Canada: Routers cyber security best practices (ITSAP.80.019) Security considerations for edge devices (ITSM.80.101) Guidance on securely configuring network protocols (ITSP.40.062) Baseline security requirements for network security zones (ITSP.80.022) Top 10 IT security actions to protect Internet-connected networks and information (ITSM.10.089) Works cited [1] FBI. Russian Government Cyber Actors Targeting Networking Devices, Critical Infrastructure. Alert Number: I-082025-PSA. 2025. https://www.ic3.gov/PSA/2025/PSA250820 [2] NSA. Cisco Smart Install Protocol Misuse. 2017. https://media.defense.gov/2019/Jul/16/2002157833/-1/-1/0/CSA-CISCO-SMART-INSTALL-PROTOCOL-MISUSE.PDF [3] NSA. Network Infrastructure Security Guide. 2023. https://media.defense.gov/2022/Jun/15/2003018261/-1/-1/0/CTR_NSA_NETWORK_INFRASTRUCTURE_SECURITY_GUIDE_20220615.PDF [4] NSA. Cybersecurity Information Sheet Cisco Password Types: Best Practices. 2022. https://media.defense.gov/2022/Feb/17/2002940795/-1/-1/0/CSI_CISCO_PASSWORD_TYPES_BEST_PRACTICES_20220217.PDF [5] NSA. Cybersecurity Information Sheet: Reducing the Risk of Simple Network Management Protocol (SNMP) Abuse. 2026. https://media.defense.gov/2026/Jul/09/2003959459/-1/-1/0/CSI_REDUCING_RISK_OF_SNMP_ABUSE.PDF Footnotes 1 Národní úřad pro kybernetickou a informační bezpečnost 2 Forsvarets Efterretningstjeneste 3 Välisluureamet 4 Riigi Infosüsteem Amet 5 Sotilastiedustelu 6 Suojelupoliisi 7 Agence nationale de la sécurité des systèmes d’information 8 Agenzia Informazioni e Sicurezza Esterna 9 Agenzia Informazioni e Sicurezza Interna 10 Służba Kontrwywiadu Wojskowego 11 Nationellt Cybersäkerhetscenter 12 MITRE and ATT&CK are registered trademarks of The MITRE Corporation. MITRE DEFEND is a trademark of the MITRE Corporation. 13 CVE-2008-4128 only affects end-of-life Cisco devices. Disclaimer of Endorsement The information and opinions contained in this document are provided "as is" and without any warranties or guarantees. Reference herein to any specific commercial products, process, or service by trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement, recommendation, or favoring by the United States Government, and this guidance shall not be used for advertising or product endorsement purposes. Purpose This document was developed in furtherance of the authoring agencies’ cybersecurity missions, including their responsibilities to identify and disseminate threats, and to develop and issue cybersecurity specifications and mitigations. This information may be shared broadly to reach all appropriate stakeholders. Contact United States organizations National Security Agency (NSA) Cybersecurity Report Feedback: CybersecurityReports@nsa.gov Defense Industrial Base Inquiries and Cybersecurity Services: DIB_Defense@cyber.nsa.gov Media Inquiries / Press Desk: NSA Media Relations: 443-634-0721, MediaRelations@nsa.gov Cybersecurity and Infrastructure Security Agency (CISA) and Federal Bureau of Investigation (FBI) U.S. organizations are encouraged to report suspicious or criminal activity related to information in this advisory to CISA via the agency’s Incident Reporting System, its 24/7 Operations Center (report@cisa.gov or 888-282-0870), or your local FBI field office. When available, please include the following information regarding the incident: date, time, and location of the incident; type of activity; number of people affected; type of equipment user for the activity; the name of the submitting company or organization; and a designated point of contact. United States Department of Defense Cyber Crime Center (DC3) Defense Industrial Base Inquiries and Cybersecurity Services: DC3.DCISE@us.af.mil Defense Industrial Base mandatory cyber incident reporting as required by 10 U.S. Code Sections 391 and 393 and Defense Federal Acquisition Regulation Supplement (DFARS) 252.204-7012 is submitted at https://dibnet.dod.mil. Media Inquiries / Press Desk: DC3.Information@us.af.mil Australian organizations Australian Signals Directorate Visit cyber.gov.au or call 1300 292 371 (1300 CYBER 1) to report cybersecurity incidents and access alerts and advisories. Canadian organizations The Canadian Centre for Cyber Security (Cyber Centre), part of the Communications Security Establishment, encourages Canadian organizations to report cyber incidents and to strengthen the security of their networking devices. Report an incident or suspicious activity to the Cyber Centre by email at contact@cyber.gc.ca, online via the reporting tool Report a cyber incident - Canadian Centre for Cyber Security or by phone at 1-833-CYBER-88 (1-833-292-3788). New Zealand organizations New Zealand National Cyber Security Centre (NCSC-NZ): info@ncsc.govt.nz United Kingdom organizations Report significant cyber security incidents to ncsc.gov.uk/report-an-incident (monitored 24/7) Estonia organizations Estonian Foreign Intelligence Service (EFIS): info@valisluureamet.ee Finnish organizations Finnish Security and Intelligence Service: supo.fi/en/contact French organizations French organizations are encouraged to report suspicious activity or incident related information found in this advisory by contacting ANSSI/CERT-FR at: cert-fr@ssi.gouv.fr or by phone at: 3218 or +33 9 70 83 32 18. Italian Organizations Italian External Intelligence and Security Agency (AISE): Visit https://www.sicurezzanazionale.gov.it/ Italian Internal Intelligence and Security Agency (AISI): Visit https://www.sicurezzanazionale.gov.it/ Appendix A: MITRE ATT&CK tactics and techniques See Table 1 through Table 10 for all the threat actor tactics and techniques referenced in this advisory. Table 1: Reconnaissance Technique Title ID Use Active Scanning: Scanning IP Blocks T1595.001 Scan range of IP addresses Active Scanning: Vulnerability Scanning T1595.002 Scan victims for vulnerabilities that can be used during targeting Table 2: Resource Development Technique Title ID Use Acquire Infrastructure: Virtual Private Servers T1583.003 Leverage VPS as infrastructure Compromise Infrastructure: Network Devices T1584.008 Compromise intermediate routers Obtain Capabilities: Exploits T1588.005 Use publicly available code to exploit vulnerable devices Table 3: Initial Access Technique Title ID Use Exploit Public-Facing Application T1190 Exploit publicly known CVEs Proxy T1090 Use a connection proxy to direct network traffic Table 4: Execution Technique Title ID Use System Services T1569 Executing commands via SNMP Table 5: Privilege Escalation Technique Title ID Use Exploitation for Privilege Escalation T1068 Exploit publicly known CVEs for escalated privileges Table 6: Stealth Technique Title ID Use Obfuscated Files or Information T1027 Obfuscate source IP addresses in system logs, as actions may be recorded as originating from local IP addresses Table 7: Credential Access Technique Title ID Use OS Credential Dumping T1003 Collect router configuration with weak Cisco Type 7 passwords and Type 0 Table 8: Collection Technique Title ID Use Data from Configuration Repository: SNMP (MIB Dump) T1602.001 Target MIB to collect network information via SNMP Data from Configuration Repository: Network Device Configuration Dump T1602.002 Acquire credentials by collecting network device configurations Table 9: Command and Control Technique Title ID Use Proxy T1090 Use VPS for C2 Application Layer Protocol T1071 Open and expose a variety of different services, including TFTP and FTP Table 10: Exfiltration Technique Title ID Use Exfiltration Over Alternative Protocol T1048 Exfiltrating over a different protocol than that of the existing command and control channel. Appendix B: MITRE D3FEND countermeasures See Table 11 for a mapping of several of the cybersecurity countermeasures mentioned in this advisory. Table 11: MITRE D3FEND Countermeasures Countermeasure Title ID Description Application Configuration Hardening D3-ACH Use SNMPv3 and disable SNMPv1 and SNMPv2. Use SNMP allowlisting to restrict access to OIDs and MIBs. Disable Cisco Smart Install. Message Authentication D3-MAN Use SNMPv3 with strong authentication. Message Encryption D3-MENCR Use SNMPv3 to encrypt payloads. Credential Hardening D3-CH Use strong, unique passwords and store them securely. Platform Monitoring D3-PM Monitor for unusual credentials. Monitor SNMP Set-Requests for OIDs targeting sensitive device data. Network Traffic Filtering D3-NTF Use ACLs to only allow management protocols from management devices. Block TFTP, SMI, and SNMP at edge firewalls. Network Vulnerability Assessment D3-NVA Use an attack surface management service.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2008-4128 Cisco IOS Cross-Site Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2008-4128 Cisco IOS Cross-Site Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
Browse saved snapshots