Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jul 22, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-16232 Check Point SmartConsole Improper Authentication Vulnerability CVE-2026-50522 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-16232 Check Point SmartConsole Improper Authentication Vulnerability CVE-2026-50522 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Tycon Systems TPDIN-Monitor-WEB2

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 are affected: TPDIN-Monitor-WEB2 2.3.9 CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 are affected: TPDIN-Monitor-WEB2 2.3.9 CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Authentication Bypass Using an Alternate Path or Channel, Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-61884 The web management interface of the affected device does not perform server-side validation of credentials during the login process. By submitting empty values for both credential fields, an unauthenticated remote attacker can bypass the authentication check and establish a valid administrative session. This grants full access to device controls including power relay management, device reboot, remote access service configuration, and network settings, which could allow an attacker to disrupt connected infrastructure or cause physical damage to equipment. View CVE Details Affected Products Tycon Systems TPDIN-Monitor-WEB2 Vendor: Tycon Systems Product Version: Tycon Systems TPDIN-Monitor-WEB2: 2.3.9 Product Status: known_affected Remediations Vendor fix Tycon Systems did not respond to CISA's attempts at coordination. Users of Tycon Systems TPDIN-Monitor-WEB2 are encouraged to contact Tycon Systems and keep their systems up to date. https://www.tyconsystems.com/contact Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-55985 The device's web management interface stores and displays system credentials in cleartext on a certain configuration page accessible to authenticated users. Any party with access to the administrative dashboard can immediately read these credentials, which may be used to compromise other systems on the local network. View CVE Details Affected Products Tycon Systems TPDIN-Monitor-WEB2 Vendor: Tycon Systems Product Version: Tycon Systems TPDIN-Monitor-WEB2: 2.3.9 Product Status: known_affected Remediations Vendor fix Tycon Systems did not respond to CISA's attempts at coordination. Users of Tycon Systems TPDIN-Monitor-WEB2 are encouraged to contact Tycon Systems and keep their systems up to date. https://www.tyconsystems.com/contact Relevant CWE: CWE-312 Cleartext Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Abdiwelli Guled reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-21 Date Revision Summary 2026-07-21 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SIDIS Secured SmartPlug

View CSAF Summary SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version. The following versions of Siemens SIDIS Secured SmartPlug are affected: SIDIS Secured SmartPlug vers:intdot/<7.26.0310 CVSS…
Read full source summary
View CSAF Summary SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version. The following versions of Siemens SIDIS Secured SmartPlug are affected: SIDIS Secured SmartPlug vers:intdot/<7.26.0310 CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens SIDIS Secured SmartPlug Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Reusing a Nonce, Key Pair in Encryption, Out-of-bounds Write, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Integer Overflow or Wraparound, Out-of-bounds Read, Covert Timing Channel, Detection of Error Condition Without Action, Incorrect Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2022-23303 The implementations of SAE in hostapd before 2.10 and wpa_supplicant before 2.10 are vulnerable to side channel attacks as a result of cache access patterns. NOTE: this issue exists because of an incomplete fix for CVE-2019-9494. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2022-23304 The implementations of EAP-pwd in hostapd before 2.10 and wpa_supplicant before 2.10 are vulnerable to side-channel attacks as a result of cache access patterns. NOTE: this issue exists because of an incomplete fix for CVE-2019-9495. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-37660 In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-323 Reusing a Nonce, Key Pair in Encryption Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2022-48174 There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicles, this vulnerability can be executed from command to arbitrary code execution. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-5222 A stack buffer overflow was found in Internationl components for unicode (ICU ). While running the genrb binary, the 'subtag' struct overflowed at the SRBRoot::addTag function. This issue may lead to memory corruption and local arbitrary code execution. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-5914 A vulnerability has been identified in the libarchive library, specifically within the archive_read_format_rar_seek_data() function. This flaw involves an integer overflow that can ultimately lead to a double-free condition. Exploiting a double-free vulnerability can result in memory corruption, enabling an attacker to execute arbitrary code or cause a denial-of-service condition. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-9230 Issue summary: An application trying to decrypt CMS messages encrypted using password based encryption can trigger an out-of-bounds read and write. Impact summary: This out-of-bounds read may trigger a crash which leads to Denial of Service for an application. The out-of-bounds write can cause a memory corruption which can have various consequences including a Denial of Service or Execution of attacker-supplied code. Although the consequences of a successful exploit of this vulnerability could be severe, the probability that the attacker would be able to perform it is low. Besides, password based (PWRI) encryption support in CMS messages is very rarely used. For that reason the issue was assessed as Moderate severity according to our Security Policy. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-9231 Issue summary: A timing side-channel which could potentially allow remote recovery of the private key exists in the SM2 algorithm implementation on 64 bit ARM platforms. Impact summary: A timing side-channel in SM2 signature computations on 64 bit ARM platforms could allow recovering the private key by an attacker.. While remote key recovery over a network was not attempted by the reporter, timing measurements revealed a timing signal which may allow such an attack. OpenSSL does not directly support certificates with SM2 keys in TLS, and so this CVE is not relevant in most TLS contexts. However, given that it is possible to add support for such certificates via a custom provider, coupled with the fact that in such a custom provider context the private key may be recoverable via remote timing measurements, we consider this to be a Moderate severity issue. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as SM2 is not an approved algorithm. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-385 Covert Timing Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L CVE-2025-9232 Issue summary: An application using the OpenSSL HTTP client API functions may trigger an out-of-bounds read if the 'no_proxy' environment variable is set and the host portion of the authority component of the HTTP URL is an IPv6 address. Impact summary: An out-of-bounds read can trigger a crash which leads to Denial of Service for an application. The OpenSSL HTTP client API functions can be used directly by applications but they are also used by the OCSP client functions and CMP (Certificate Management Protocol) client implementation in OpenSSL. However the URLs used by these implementations are unlikely to be controlled by an attacker. In this vulnerable code the out of bounds read can only trigger a crash. Furthermore the vulnerability requires an attacker-controlled URL to be passed from an application to the OpenSSL function and the user has to have a 'no_proxy' environment variable set. For the aforementioned reasons the issue was assessed as Low severity. The vulnerable code was introduced in the following patch releases: 3.0.16, 3.1.8, 3.2.4, 3.3.3, 3.4.0 and 3.5.0. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as the HTTP client implementation is outside the OpenSSL FIPS module boundary. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-26465 A vulnerability was found in OpenSSH when the VerifyHostKeyDNS option is enabled. A machine-in-the-middle attack can be performed by a malicious machine impersonating a legit server. This issue occurs due to how OpenSSH mishandles error codes in specific conditions when verifying the host key. For an attack to be considered successful, the attacker needs to manage to exhaust the client's memory resource first, turning the attack complexity high. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-390 Detection of Error Condition Without Action Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N CVE-2025-32462 Sudo before 1.9.17p1, when used with a sudoers file that specifies a host that is neither the current host nor ALL, allows listed users to execute commands on unintended machines. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.8 LOW CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:L/A:N CVE-2026-5121 A flaw was found in libarchive. On 32-bit systems, an integer overflow vulnerability exists in the zisofs block pointer allocation logic. A remote attacker can exploit this by providing a specially crafted ISO9660 image, which can lead to a heap buffer overflow. This could potentially allow for arbitrary code execution on the affected system. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-585531 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Publication Date 2026-07-21 2 Initial CISA Republication of Siemens ProductCERT SSA-585531 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-27137 DD-WRT Stack-Based Buffer Overflow Vulnerability CVE-2026-0770 Langflow Inclusion of Functionality from Untrusted Control Sphere Vulnerability CVE-2026-63030 WordPress Core Interpretation Conflict Vulnerability CVE-2026-60137 WordPress Core SQL Injection Vulnerability…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-27137 DD-WRT Stack-Based Buffer Overflow Vulnerability CVE-2026-0770 Langflow Inclusion of Functionality from Untrusted Control Sphere Vulnerability CVE-2026-63030 WordPress Core Interpretation Conflict Vulnerability CVE-2026-60137 WordPress Core SQL Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Siemens IAM Client

View CSAF Summary Multiple Siemens products are affected by unquoted search path vulnerability in IAM Client. This could allow an authenticated local attacker to perform privilege escalation. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not…
Read full source summary
View CSAF Summary Multiple Siemens products are affected by unquoted search path vulnerability in IAM Client. This could allow an authenticated local attacker to perform privilege escalation. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens IAM Client are affected: COMOS V10.4.5 vers:intdot/<10.4.5.0.2 COMOS V10.6 vers:intdot/<10.6.1 Designcenter NX vers:intdot/<2512.7000 Simcenter 3D vers:intdot/<2512.7000 Simcenter Femap V2506 vers:intdot/<2506.0003 Simcenter Femap V2512 vers:intdot/<2512.0002 Simcenter Nastran vers:intdot/<2606 Simcenter STAR-CCM+ vers:intdot/<2606 Solid Edge SE2025 vers:intdot/<225.0.13.3 Solid Edge SE2026 vers:intdot/<226.0.04.003 Teamcenter Visualization V2412 vers:intdot/<2412.0012 Teamcenter Visualization V2506 vers:intdot/<2506.0009 Teamcenter Visualization V2512 vers:intdot/<2512.2605 Tecnomatix Plant Simulation V2404 vers:intdot/<2404.0022 Tecnomatix Plant Simulation V2504 vers:intdot/<2504.0010 Tecnomatix Process Simulate vers:intdot/<2606 CVSS Vendor Equipment Vulnerabilities v3 6.7 Siemens Siemens IAM Client Untrusted Search Path Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40945 Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access. View CVE Details Affected Products Siemens IAM Client Vendor: Siemens Product Version: COMOS V10.4.5 < V10.4.5.0.2, COMOS V10.6 < V10.6.1, Designcenter NX < V2512.7000, Simcenter 3D < V2512.7000, Simcenter Femap V2506 < V2506.0003, Simcenter Femap V2512 < V2512.0002, Simcenter Nastran < V2606, Simcenter STAR-CCM+ < V2606, Solid Edge SE2025 < V225.0.13.3, Solid Edge SE2026 < V226.0.04.003, Teamcenter Visualization V2412 < V2412.0012, Teamcenter Visualization V2506 < V2506.0009, Teamcenter Visualization V2512 < V2512.2605, Tecnomatix Plant Simulation V2404 < V2404.0022, Tecnomatix Plant Simulation V2504 < V2504.0010, Tecnomatix Process Simulate < V2606 Product Status: known_affected Remediations Vendor fix Update to V10.6.1 or later version https://support.sw.siemens.com/product/222981661/ Vendor fix Update to V225.0 Update 13 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 04 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V2404.0022 or later version https://support.sw.siemens.com/product/297028302/ Vendor fix Update to V2412.0012 or later version https://support.sw.siemens.com/product/229029598/ Vendor fix Update to V2504.0010 or later version https://support.sw.siemens.com/product/297028302/ Vendor fix Update to V2506.0003 or later version https://support.sw.siemens.com/product/275652363/ Vendor fix Update to V2506.0009 or later version https://support.sw.siemens.com/product/229029598/ Vendor fix Update to V2512.0002 or later version https://support.sw.siemens.com/product/275652363/ Vendor fix Update to V2512.2605 or later version https://support.sw.siemens.com/product/229029598/ Vendor fix Update to V2512.7000 or later version https://support.sw.siemens.com/product/209349590/ Vendor fix Update to V2512.7000 or later version https://support.sw.siemens.com/product/289054037/ Vendor fix Update to V2606 or later version https://support.sw.siemens.com/product/289054037/ Vendor fix Update to V10.4.5.0.2 or later version. Contact customer support to receive patch and update information Relevant CWE: CWE-426 Untrusted Search Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-288252 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Publication Date 2026-07-21 2 Initial CISA Republication of Siemens ProductCERT SSA-288252 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW

View CSAF Summary Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/ The following versions of Siemens RUGGEDCOM APE1808 with…
Read full source summary
View CSAF Summary Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/ The following versions of Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW are affected: RUGGEDCOM APE1808 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Missing Authorization, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-0266 A cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS® software enables a malicious authenticated administrator to store a JavaScript payload using the web interface. This issue is applicable to PAN-OS software on PA-Series and VM-Series firewalls and on Panorama (virtual and M-Series). Cloud NGFW and Prisma® Access are not affected by this vulnerability. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Vendor: Siemens Product Version: RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.4 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N CVE-2026-0272 A privilege escalation vulnerability in Palo Alto Networks PAN-OS® software allows an authenticated administrator with access to the Command Line Interface (CLI) to perform actions on the device with root privileges. The security risk posed by this issue is significantly minimized when CLI access is restricted to a limited group of administrators and by restricting access to the management interface to only trusted internal IP addresses according to our recommended best practice deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . This issue is applicable to PAN-OS software on PA-Series and VM-Series firewalls and on Panorama (virtual and M-Series). Cloud NGFW, and Prisma® Access are not impacted by this vulnerability. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Vendor: Siemens Product Version: RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N CVE-2026-0273 A command injection vulnerability in Palo Alto Networks PAN-OS® software enables an authenticated administrator to bypass system restrictions and run arbitrary commands as a root user. To be able to exploit this issue, the user must have access to the PAN-OS CLI or Web UI. The security risk posed by this issue is significantly minimized when CLI access is restricted to a limited group of administrators and by restricting access to the management web interface to only trusted internal IP addresses according to our recommended best practice deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . This issue is applicable to PAN-OS software on PA-Series and VM-Series firewalls and on Panorama (virtual and M-Series). Cloud NGFW and Prisma® Access are not affected by this vulnerability. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Vendor: Siemens Product Version: RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-104023 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Publication Date 2026-07-21 2 Initial CISA Republication of Siemens ProductCERT SSA-104023 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 1734 POINT I/O

View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1734 POINT I/O are affected: 1734 POINT I/O 3.023 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1734 POINT I/O Allocation of Resources Without Limits or Throttling Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1734 POINT I/O are affected: 1734 POINT I/O 3.023 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1734 POINT I/O Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10573 A denial-of-service security issue exists in 1734 POINT I/O module. The security issue stems from improper handling of crafted CIP messages, which can cause the module to enter a faulted state. A restart is required to recover. View CVE Details Affected Products Rockwell Automation 1734 POINT I/O Vendor: Rockwell Automation Product Version: Rockwell Automation 1734 POINT I/O: 3.023 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users are to migrate to 5034-OB8. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-21 Date Revision Summary 2026-07-21 1 Initial Republication of Rockwell Automation Security Advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 1718-AENTR/1719-AENTR

View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1718-AENTR/1719-AENTR are affected: 1718/ 1719 Ex I/O 3.011 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1718-AENTR/1719-AENTR Allocation of Resources Without Limits or Throttling…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1718-AENTR/1719-AENTR are affected: 1718/ 1719 Ex I/O 3.011 CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1718-AENTR/1719-AENTR Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9140 A denial-of-service security issue exists in the 1719-AENTR. The security issue stems from improper handling of a UDP unicast network storm, which causes the device to become overloaded and lose communication. A power cycle is required to recover. View CVE Details Affected Products Rockwell Automation 1718-AENTR/1719-AENTR Vendor: Rockwell Automation Product Version: Rockwell Automation 1718/ 1719 Ex I/O: 3.011 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to 1718/ 1719 Ex I/O version 3.012 or later. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-21 Date Revision Summary 2026-07-21 1 Initial Republication of Rockwell Automation Security Advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Studio 5000 Logix Designer

View CSAF Summary Successful exploitation of these vulnerabilities could allow for a local attacker to execute arbitrary files, alter configurations, or execute arbitrary code. The following versions of Rockwell Automation Studio 5000 Logix Designer are affected: Studio 5000 Logix Designer V36.00 (CVE-2026-9108) Studio 5000 Logix Designer V35.00 (CVE-2026-9108, CVE-2026-9127, CVE-2026-9128) Studio 5000 Logix…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow for a local attacker to execute arbitrary files, alter configurations, or execute arbitrary code. The following versions of Rockwell Automation Studio 5000 Logix Designer are affected: Studio 5000 Logix Designer V36.00 (CVE-2026-9108) Studio 5000 Logix Designer V35.00 (CVE-2026-9108, CVE-2026-9127, CVE-2026-9128) Studio 5000 Logix Designer V35.01 (CVE-2026-9108) Studio 5000 Logix Designer >=V34.00|<=V34.03 (CVE-2026-9108) Studio 5000 Logix Designer >=V33.00|<=V33.03 (CVE-2026-9108) Studio 5000 Logix Designer >=V32.00|<=V32.04 (CVE-2026-9108, CVE-2026-9127, CVE-2026-9128) Studio 5000 Logix Designer V34.00 (CVE-2026-9127) Studio 5000 Logix Designer V34.01 (CVE-2026-9127) Studio 5000 Logix Designer V33.00 (CVE-2026-9127) Studio 5000 Logix Designer V33.02 (CVE-2026-9127) Studio 5000 Logix Designer >=V34.00|<=V34.02 (CVE-2026-9128) Studio 5000 Logix Designer >=V33.00|<=V33.02 (CVE-2026-9128) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Studio 5000 Logix Designer Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Incorrect Authorization, Unquoted Search Path or Element Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9108 A path traversal security issue exists within Studio 5000 Logix Designer due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution. View CVE Details Affected Products Rockwell Automation Studio 5000 Logix Designer Vendor: Rockwell Automation Product Version: Rockwell Automation Studio 5000 Logix Designer: V36.00, Rockwell Automation Studio 5000 Logix Designer: V35.00, Rockwell Automation Studio 5000 Logix Designer: V35.01, Rockwell Automation Studio 5000 Logix Designer: >=V34.00|<=V34.03, Rockwell Automation Studio 5000 Logix Designer: >=V33.00|<=V33.03, Rockwell Automation Studio 5000 Logix Designer: >=V32.00|<=V32.04 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: Studio 5000 Logix Designer: V37.00, 36.01, 35.02, 34.04, 33.04, 32.05 (CVE-2026-9108) Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 4.0 5.4 MEDIUM CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-9127 A remote code execution security issue exists within Studio 5000 Logix Designer due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality. View CVE Details Affected Products Rockwell Automation Studio 5000 Logix Designer Vendor: Rockwell Automation Product Version: Rockwell Automation Studio 5000 Logix Designer: V35.00, Rockwell Automation Studio 5000 Logix Designer: >=V32.00|<=V32.04, Rockwell Automation Studio 5000 Logix Designer: V34.00, Rockwell Automation Studio 5000 Logix Designer: V34.01, Rockwell Automation Studio 5000 Logix Designer: V33.00, Rockwell Automation Studio 5000 Logix Designer: V33.02 Product Status: known_affected Remediations Vendor fix Studio 5000 Logix Designer: V36.00, 35.01, 34.02, 33.02, 32.05 (CVE-2026-9127) Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H CVE-2026-9128 A code execution security issue exists within Studio 5000 Logix Designer due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application. View CVE Details Affected Products Rockwell Automation Studio 5000 Logix Designer Vendor: Rockwell Automation Product Version: Rockwell Automation Studio 5000 Logix Designer: V35.00, Rockwell Automation Studio 5000 Logix Designer: >=V32.00|<=V32.04, Rockwell Automation Studio 5000 Logix Designer: >=V34.00|<=V34.02, Rockwell Automation Studio 5000 Logix Designer: >=V33.00|<=V33.02 Product Status: known_affected Remediations Vendor fix Studio 5000 Logix Designer: V36.00, 35.01, 34.03, 33.03, 32.05 (CVE-2026-9128) Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html Relevant CWE: CWE-428 Unquoted Search Path or Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Rockwell Automation reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity. Revision History Initial Release Date: 2026-07-21 Date Revision Summary 2026-07-21 1 Initial Republication of Rockwell Automation Security Advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens CADRA

View CSAF Summary CADRA is affected by multiple zlib and Foxit vulnerabilities. Siemens has released a new version for CADRA and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens CADRA are affected: CADRA vers:intdot/<2511, vers:all/* CVSS Vendor…
Read full source summary
View CSAF Summary CADRA is affected by multiple zlib and Foxit vulnerabilities. Siemens has released a new version for CADRA and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens CADRA are affected: CADRA vers:intdot/<2511, vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens CADRA Improper Input Validation, Incorrect Bitwise Shift of Integer, Out-of-bounds Write, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Integer Overflow or Wraparound, Access of Resource Using Incompatible Type ('Type Confusion') Background Critical Infrastructure Sectors: Chemical, Commercial Facilities, Communications, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2005-2096 zlib 1.2 and later versions allows remote attackers to cause a denial of service (crash) via a crafted compressed stream with an incomplete code description of a length greater than 1, which leads to a buffer overflow, as demonstrated using a crafted PNG file. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2016-9840 inftrees.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact by leveraging improper pointer arithmetic. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2016-9841 inffast.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact by leveraging improper pointer arithmetic. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2016-9842 The inflateMark function in inflate.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact via vectors involving left shifts of negative integers. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-1335 Incorrect Bitwise Shift of Integer Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2017-14919 Node.js before 4.8.5, 6.x before 6.11.5, and 8.x before 8.8.0 allows remote attackers to cause a denial of service (uncaught exception and crash) by leveraging a change in the zlib module 1.2.9 making 8 an invalid value for the windowBits parameter. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2018-25032 zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-37434 zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field. NOTE: only applications that call inflateGetHeader are affected. Some common applications bundle the affected zlib source code but may be unable to call inflateGetHeader (e.g., see the nodejs/node reference). View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2023-45853 MiniZip in zlib through 1.3 has an integer overflow and resultant heap-based buffer overflow in zipOpenNewFileInZip4_64 via a long filename, comment, or extra field. NOTE: MiniZip is not a supported part of the zlib product. NOTE: pyminizip through 0.2.6 is also vulnerable because it bundles an affected zlib version, and exposes the applicable MiniZip code through its compress API. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA < V2511 Product Status: known_affected Remediations Vendor fix Update to V2511 or later version Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2025-10585 Type confusion in V8 in Google Chrome prior to 140.0.7339.185 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: High) View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA Product Status: known_affected Remediations Mitigation Block access to untrusted or external web content from sensitive systems None available Currently no fix is available Relevant CWE: CWE-843 Access of Resource Using Incompatible Type ('Type Confusion') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-13223 Type Confusion in V8 in Google Chrome prior to 142.0.7444.175 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: High) View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA Product Status: known_affected Remediations Mitigation Block access to untrusted or external web content from sensitive systems None available Currently no fix is available Relevant CWE: CWE-843 Access of Resource Using Incompatible Type ('Type Confusion') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-22184 zlib versions up to and including 1.3.1.2 include a global buffer overflow in the untgz utility located under contrib/untgz. The vulnerability is limited to the standalone demonstration utility and does not affect the core zlib compression library. The flaw occurs when a user executes the untgz command with an excessively long archive name supplied via the command line, leading to an out-of-bounds write in a fixed-size global buffer. View CVE Details Affected Products Siemens CADRA Vendor: Siemens Product Version: CADRA Product Status: known_affected Remediations None available Currently no fix is available Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 0 NONE CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-470355 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Publication Date 2026-07-21 2 Initial CISA Republication of Siemens ProductCERT SSA-470355 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Services Platform

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to impersonate an authorized user on the FTSP server, resulting in unauthorized access to system configurations. The following versions of Rockwell Automation FactoryTalk Services Platform are affected: FactoryTalk Directory (FTSP) 6.60 CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to impersonate an authorized user on the FTSP server, resulting in unauthorized access to system configurations. The following versions of Rockwell Automation FactoryTalk Services Platform are affected: FactoryTalk Directory (FTSP) 6.60 CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation FactoryTalk Services Platform Weak Authentication Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10714 A security issue exists within FactoryTalk Services Platform (FTSP), allowing an attacker to bypass JWT signature validation during Okta Web Authentication. The vulnerability stems from the application not verifying that the JWT algorithm is configured for RSA, enabling an attacker to set the algorithm to "none" and craft forged tokens. This could allow an authenticated low-privilege user to impersonate any authorized user on the FTSP server, resulting in unauthorized access to system configuration and the ability to grant permissions to other systems protected by FTSP. View CVE Details Affected Products Rockwell Automation FactoryTalk Services Platform Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Directory (FTSP): 6.60 Product Status: known_affected Remediations Mitigation Users using FactoryTalk Services Platform v6.60 should apply either the individual patch (RAID 1158263) or the February 2026 Patch Roll-up, or later update. Mitigation Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell's security best practices. https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, refer to Rockwell Automation's security advisory SD1786 page. https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1786.html Relevant CWE: CWE-1390 Weak Authentication Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 8.8 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-07-21 Date Revision Summary 2026-07-21 1 Initial Republication of Rockwell Automation SD1786 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Opcenter X

View CSAF Summary Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version. The following versions of Siemens Opcenter X are affected: Opcenter X vers:intdot/<2604 CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens…
Read full source summary
View CSAF Summary Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version. The following versions of Siemens Opcenter X are affected: Opcenter X vers:intdot/<2604 CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens Opcenter X Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-56451 Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application. View CVE Details Affected Products Siemens Opcenter X Vendor: Siemens Product Version: Opcenter X < V2604 Product Status: known_affected Remediations Vendor fix Update to V2604 or later version https://support.sw.siemens.com/product/206159703/ Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-096828 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Publication Date 2026-07-21 2 Initial CISA Republication of Siemens ProductCERT SSA-096828 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AutomationDirect Productivity Suite

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389, CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerabilities v3 7 AutomationDirect AutomationDirect Productivity Suite Out-of-bounds Write, Out-of-bounds Read, Divide By Zero Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-60063 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-61389 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-60140 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This can lead to exposing sensitive information or causing the affected product to become unstable or unavailable. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-57896 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This could lead to limited information disclosure or disruption of the affected product. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-60073 An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H 4.0 5.2 MEDIUM CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-61378 A divide-by-zero vulnerability in the Productivity Suite allows a local attacker to cause a division by zero leading to a system crash. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-369 Divide By Zero Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 6.8 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Luca Borzacchiello of Nozomi Networks reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Arena

View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background…
Read full source summary
View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-8085 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8312 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8313 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the linker.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8314 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the siman.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Heinzl reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25089 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-39808 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-58644 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are frequent attack…
Read full source summary
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25089 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-39808 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-58644 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

NASA Core Flight System (cFS) Health & Safety (HS) Application

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer Dereference Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-15352 A vulnerability exists in the Health & Safety (HS) application of NASA's Core Flight System (cFS). The flaw allows the application to crash via segmentation fault when processing a routine Housekeeping Telemetry request, leading to denial of service. View CVE Details Affected Products NASA Core Flight System (cFS) Health & Safety (HS) Application Vendor: NASA Product Version: NASA Core Flight System (cFS) Health & Safety (HS) Application: <v7.0.1 Product Status: known_affected Remediations Mitigation NASA recommends users update to v7.0.1 (https://github.com/nasa/HS/releases/tag/v7.0.1) https://github.com/nasa/HS/releases/tag/v7.0.1 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Grady DeRosa reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation Flex 5000 Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12659 A denial-of-service security issue exists in the affected products. The security issue stems from improper handling of exceptional conditions when processing crafted CIP packets sent to the adapter. A power cycle is required to recover the module and associated I/O. View CVE Details Affected Products Rockwell Automation Flex 5000 Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation Flex 5000 Adapter: 6.011 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: Flex 5000 Adapter version 6.012. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisory SD1789 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1789.html). https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1789.html Relevant CWE: CWE-415 Double Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Republication of Rockwell Automation Security Advisory SD1789 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SICAM 8

View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of…
Read full source summary
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/<26.20 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) SICORE Base system vers:intdot/<26.20.0 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens SICAM 8 Active Debug Code, Initialization of a Resource with an Insecure Default, Unverified Password Change Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-54798 The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2026-54799 The affected application contains a vulnerability in its firmware update mechanism's signature validation process. This could allow an attacker to install malicious firmware, leading to persistent code execution and system compromise. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-54800 The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.8 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2026-54801 The affected application contains insufficient validation of authentication credentials when processing administrative account modifications through the web API. This could allow an authenticated attacker to bypass security controls and gain unauthorized elevated privileges. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/Communication < V26.20, SICORE Base system < V26.20.0 Product Status: known_affected Remediations Vendor fix Update to V26.20 or later version The firmware CPCI85 V26.20 is present within “CP-8031/CP-8050 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109804985/ and also within “SICAM EGS Package” V26.20 https://support.industry.siemens.com/cs/document/109972536/ Vendor fix Update to V26.20.0 or later version The firmware SICORE V26.20.0 is present within “CP-8010/CP-8012 Package” V26.20 https://support.industry.siemens.com/cs/ww/en/view/109972894/ and also within “SICAM S8000 Package” V26.20 https://support.industry.siemens.com/cs/document/109818240 Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens reported these vulnerabilities to CISA. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact Siemens: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-229470 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-09 Date Revision Summary 2026-07-09 1 Publication Date 2026-07-16 2 Initial CISA Republication of Siemens SSA-229470 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2,…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Improper Validation of Integrity Check Value Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9653 A denial-of-service security issue exists across all the 1756-EN2, EN3, and ENBT communication module due to improper validation of CIP Implicit Connection packets. An attacker on the network can exploit this by sending crafted packets to continuously disrupt device connections, though device connections will recover immediately after. View CVE Details Affected Products Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Vendor: Rockwell Automation Product Version: Rockwell Automation 1756-EN3: <=V12.001, Rockwell Automation 1756-EN2: <=V12.001, Rockwell Automation 1756-ENBT: V6.006 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users take the following actions: 1756-EN3: Update to V12.002 Vendor fix 1756-EN2: Update to V12.002 Vendor fix 1756-ENBT: Product is discontinued, fix is unavailable Relevant CWE: CWE-354 Improper Validation of Integrity Check Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Tyler Lentz of Idaho National Laboratory reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk DataMosaix

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9292 A Stored Cross-Site Scripting security issue exists within FactoryTalk DataMosaix Private Cloud. The vulnerability stems from improper neutralization of user-supplied input within the Workflows configuration. An authenticated attacker with high privileges can inject malicious scripts that are permanently stored on the server. This vulnerability can result in the execution of malicious JavaScript when other users access the affected page, potentially allowing for account takeover, credential theft, or redirection to a malicious website. View CVE Details Affected Products Rockwell Automation FactoryTalk DataMosaix Vendor: Rockwell Automation Product Version: Rockwell Automation DataMosaix Private Cloud: <=8.02 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: DataMosaix Private Cloud versions 8.03 or later. Mitigation Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see Rockwell Automation Security Advisory SD1787 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1787.html). https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1787.html Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N 4.0 8.4 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Republication of Rockwell Automation Security Advisory SD1787 Legal Notice and Terms of Use
Browse saved snapshots