· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-64849 MLflow Server-Side Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-64849 MLflow Server-Side Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Defending Against an Active Threat to Siemens S7 Series PLCs

Executive summary Note: This advisory relates to an active threat to Siemens S7 Series programmable logic controllers (PLCs). However, ongoing PLC targeting activity is broader than Siemens PLCs. All PLC owners and operators should apply relevant mitigations to reduce the risk to their devices and systems. The Siemens-specific content in this advisory should be understood and applied as one subset of the wider…
Read full source summary
Executive summary Note: This advisory relates to an active threat to Siemens S7 Series programmable logic controllers (PLCs). However, ongoing PLC targeting activity is broader than Siemens PLCs. All PLC owners and operators should apply relevant mitigations to reduce the risk to their devices and systems. The Siemens-specific content in this advisory should be understood and applied as one subset of the wider threat landscape. Top Mitigations Inventory all Siemens S7 Series programmable logic controllers (PLCs) Apply critical security patches Ensure PLCs are not accessible from the Internet Strengthen access controls Monitor for unauthorized activity Harden PLC services, protocols, and ladder logic integrity Hunt for anomalies that may indicate a compromise The National Security Agency (NSA), Cybersecurity and Infrastructure Security Agency (CISA), Federal Bureau of Investigation (FBI), Department of Energy (DOE), and Environmental Protection Agency (EPA)—hereafter referred to as the authoring agencies—are releasing this Cybersecurity Advisory to warn owners and operators of industrial control systems (ICSs) of an active cyber threat to Siemens S7 Series PLCs and provide relevant mitigations to protect and defend them. The threat actors are conducting reconnaissance and capability development against U.S.-based Siemens PLC installations using AI-generated exploitation scripts disguised as legitimate monitoring tools. The actors leverage Internet scanning services to find Internet-exposed PLCs running outdated software or that are otherwise poorly protected. The U.S. critical infrastructure sectors most targeted by this threat activity include Critical Manufacturing, Energy, Water and Wastewater, Chemical, Food and Agriculture, and Commercial Facilities. This is not a theoretical risk—it is an active threat. Depending on the specific circumstances, exploitation of poorly protected PLCs could lead to disruption of critical industrial processes, safety incidents, downtime or equipment damage, compromise of sensitive data, compliance violations, and cascading impacts across interconnected systems. The authoring agencies urge all owners and operators of operational technology (OT) systems using Siemens S7 Series and other PLC devices to proactively check their systems: are properly protected with all applicable security patches and updates, are isolated from the Internet wherever possible, have strong access controls, and employ security tooling to monitor ICS environments for anomalous or malicious activity. These mitigations are particularly important for owners and operators who work with third-party service providers or system integrators who may have remote access to PLCs, as the asset owners may not realize that their systems are exposed and at risk. Technical details Note: This advisory uses the MITRE ATT&CK® Matrix for ICS1 framework, version 19, and the MITRE ATT&CK Matrix for Enterprise framework, version 19. This advisory also uses MITRE D3FENDTM, version 1.5.0. See Appendix A and Appendix B for tables of the activity mapped to MITRE ATT&CK and MITRE D3FEND tactics, techniques, and countermeasures. Threat actor targeting Threat actors are actively targeting the following Siemens PLC models: S7-200 Series (all CPU variants) S7-300 Series (all CPU variants including 314, 315, 317 models) S7-400 Series (all CPU variants) S7-1200 Series (CPU 1211C, 1212C, 1214C, 1215C, 1217C variants) S7-1500 Series (all CPU variants, including F-series safety controllers) Threat actors are using AI assistance to generate exploitation scripts using publicly available information on these Siemens S7 Series PLCs for initial access, credential access, denial of service, and other objectives. If these PLCs are exposed to the Internet or insufficiently segmented, then threat actors can exploit various critical and high severity known vulnerabilities in these PLCs. Note: Using AI to generate exploitation scripts represents an evolution in threat actor capabilities, dramatically reducing the technical expertise and time required to develop working ICS exploitation scripts and malicious tools. In addition, AI enables adversaries to rapidly leverage additional attack vectors and adapt to defensive measures. Threat actors can easily collect public information about vulnerabilities and weaknesses, find exposed and exploitable PLCs, and use AI-generated scripts to act on that information. If PLCs are exposed to the Internet, they are at high risk for exploitation. Threat actors are leveraging open source industrial automation libraries—specifically snap7.dll/python-snap7—combined with AI-assisted scripting to create custom tools that mimic legitimate OT monitoring solutions. These tools provide read/write access to Siemens S7 Series PLC memory, configuration data, and ladder logic programs via the S7comm protocol. Threat actor techniques Threat actors are: Using Internet scanning services (e.g., Censys, ZoomEye) to identify Internet-exposed or insufficiently segmented Siemens S7 Series PLCs [T1596.005] Rapidly iterating exploit code through AI-assisted development, lowering technical barriers to ICS attacks [T1587.004, T1588.007] Taking advantage of insecure credentials to access exposed devices that have unconfigured (default) or minimally configured authentication [T1694] Deploying AI-generated Python scripts that incorporate the snap7.dll library from public repositories [T0834] to gain read/write access to the PLC and mimic legitimate tools Masquerading malicious scripts as legitimate monitoring tools to evade detection by security teams [T0849] Conducting read/write operations on data blocks, potentially for reconnaissance, capability testing, or pre-positioning for effects operations [T0893, T0821] The authoring agencies assess this activity pattern is likely intended as persistent reconnaissance in targeted sectors and facilities to develop capabilities and prepare to cause operational effects against critical infrastructure. For capability development, actors are testing and refining their exploitation techniques against specific PLC models to improve their ability to compromise the PLCs. To prepare for operational effects, actors are leveraging read access to understand target environments, enabling preparation and positioning for future write operations to cause disruption or other operational impacts. Potential operational impacts The U.S. critical infrastructure sectors most targeted by this threat activity include Critical Manufacturing, Energy, Water and Wastewater, Chemical, Food and Agriculture, and Commercial Facilities. Additionally, Siemens S7 Series PLCs are used in other sectors, including the Defense Industrial Base (DIB), and could be targeted there as well. Unauthorized access to PLCs could result in: Disruption of critical industrial processes affecting production throughput, product quality, and public services Safety incidents affecting personnel through manipulation of safety interlocks, emergency shutdown systems, or process parameters Equipment damage and extended operational downtime from process upsets, improper sequencing, or forced equipment operation outside design parameters Compromise of sensitive operational data, including proprietary process recipes, control strategies, and facility configurations Cascading impacts across interconnected systems affecting supply chains, dependent facilities, and integrated business operations Regulatory compliance violations and potential liability from process safety management failures Mitigation actions Since threat actors are developing capabilities using AI to compromise PLCs using known vulnerabilities, misconfigurations, and other weaknesses and then may use compromised PLCs to interfere with normal operations, the authoring agencies urge organizations to implement comprehensive defense-in-depth strategies, in addition to Common Vulnerabilities and Exposures (CVE) remediation, to protect and defend their PLCs. Detection opportunities Organizations should implement detection strategies and hunt for anomalies that may indicate a compromise, focusing on [D3-PM]: Anomalous S7comm behavior: Connections from non-engineering workstations, unusual data block access patterns, or write operations outside change windows Reconnaissance indicators: Sequential IP scanning on port 102, repeated connection attempts with varying parameters, or enumeration of CPU properties Tool artifacts: Snap7.dll library usage outside approved engineering workstations, Python scripts with S7comm functionality, or unauthorized monitoring software installations Temporal anomalies: S7comm activity during off-hours, unexpected connection patterns consistent with automated scripting rather than human operators, or configuration changes without corresponding work orders or change tickets Geographic anomalies: Connections originating from unexpected countries or IP ranges not associated with vendors or integrators Preventative hardening actions To counter threats to PLCs, the authoring agencies recommend all PLC owners and operators follow the mitigations in joint guidance Primary Mitigations to Reduce Cyber Threats to Operational Technology. To harden Siemens S7 Series PLCs, the authoring agencies strongly urge all owners implement the hardening steps below. Entities that rely on systems integrators or third-party managed service providers should share this advisory with those parties and request implementation of the following mitigations: 1. Conduct an immediate inventory of all Siemens S7 Series PLCs in your environment [D3-HCI]: Verify current firmware versions for all S7-200, S7-300, S7-400, S7-1200, and S7-1500 controllers against backup gold copy Identify any systems directly or indirectly accessible from untrusted networks Map all engineering workstations with Totally Integrated Automation (TIA) Portal, STEP 7, or S7 programming access 2. Apply critical security patches as soon as possible [D3-SU]: Update Siemens S7 Series PLC firmware to the latest versions that address known vulnerabilities Prioritize Internet-facing or demilitarized zone (DMZ)-resident controllers Update TIA Portal and STEP 7 software to current versions Consult Siemens ProductCERT advisories for information on known vulnerabilities, along with relevant workarounds and mitigations Test all updates in a development environment before production deployment 3. Verify network segmentation and ensure PLCs are NOT accessible from the Internet [D3-NI]: Audit firewall rules for any exposed S7comm services (Transmission Control Protocol [TCP] port 102) Block TCP port 102 at perimeter firewalls entirely Implement a DMZ architecture that separates OT and IT networks Deploy unidirectional gateways for data historian connections where appropriate Verify there is no unauthorized routing between corporate and industrial networks 4. Review and strengthen access controls [D3-NAM, D3-CH]: Restrict TIA Portal/STEP 7 access to authorized engineering workstations only by MAC/IP allowlisting on PLCs Enable PLC password protection on all Siemens S7 Series controllers Configure protection levels (such as write protection and read/write protection) on Siemens S7 Series devices Remove or change default SNMP community strings Implement application allowlisting on all engineering workstations Enable multi-factor authentication for all remote access to OT networks 5. Enable comprehensive logging and monitoring [D3-PM, D3-NTA]: Deploy ICS-aware intrusion detection (e.g., Claroty, Dragos Platform, Nozomi Networks, or similar) Monitor all S7comm traffic on TCP port 102 for connections outside maintenance windows Alert on unauthorized PUT/GET operations, especially write commands to data blocks or configuration areas of memory Log all TIA Portal/STEP 7 connections to PLCs with timestamps and source IPs Establish a baseline for legitimate behavior and configure monitoring tools to alert on deviations Monitor for Python processes with snap7.dll library imports on engineering workstations Watch for sequential IP scanning patterns or block reads of configuration data 6. Implement S7-specific hardening measures [D3-ACH]: Disable web servers on Siemens S7 Series devices if not operationally required Disable unused communication protocols (such as Modbus TCP and PROFINET, if they are not required) Configure connection resources to limit simultaneous S7comm sessions Enable TIA Portal/STEP 7 “complete restart protection” and “know-how protection” features where available Evaluate for ladder logic changes in online/offline modes 7. Contact Siemens for model-specific guidance: Engage Siemens Technical Support for hardening recommendations specific to your CPU models and firmware versions Verify patch compatibility with your specific operational environment and third-party integrations Request assistance with protection level configuration and access control implementation Conclusion There is an active threat targeting Internet-exposed Siemens S7 Series PLCs. The combination of known vulnerabilities, accessible exploitation libraries, and AI-assisted development creates a high-probability attack scenario against inadequately protected PLC installations. Organizations should treat this Cybersecurity Advisory with urgency and coordinate response efforts across security, engineering, executive leadership, plant operations, and vendor support teams to implement the recommended detection and hardening actions. Resources Primary Mitigations to Reduce Cyber Threats to Operational Technology Secure connectivity principles for Operational Technology (OT): How organisations should design, secure, and manage connectivity in OT Control System Defense: Know the Opponent Incident reporting U.S. organizations are encouraged to report suspicious or criminal activity related to information in this advisory to CISA and/or the FBI. Contact CISA via CISA’s 24/7 Operations Center at contact@cisa.dhs.gov or 1-844-Say-CISA (1-844-729-2472). File a claim with FBI’s Internet Crime Complaint Center (IC3) or contact your local FBI field office. When available, please include the following information regarding the incident: Date, time, and location of the incident; Type of activity; Number of people affected; Type of equipment used for the activity; and Name of the submitting company or organization, and a designated point of contact. Entities required to report incidents to DOE should follow established reporting requirements, as appropriate. For other energy sector inquiries, contact EnergySRMA@hq.doe.gov. In addition, consider contacting Siemens ProductCERT via https://www.siemens.com/cert or email productcert@siemens.com. Disclaimer of endorsement The information and opinions contained in this document are provided "as is" and without any warranties or guarantees. Reference herein to any specific commercial products, process, or service by trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement, recommendation, or favoring by the United States Government, and this guidance shall not be used for advertising or product endorsement purposes. Purpose This document was developed in furtherance of the authoring agencies’ cybersecurity missions, including their responsibilities to identify and disseminate threats and to develop and issue cybersecurity specifications and mitigations. This information may be shared broadly to reach all appropriate stakeholders. Contact Cybersecurity Report Feedback: CybersecurityReports@nsa.gov Defense Industrial Base Inquiries and Cybersecurity Services: DIB_Defense@cyber.nsa.gov Media Inquiries / Press Desk: NSA Media Relations: 443-634-0721, MediaRelations@nsa.gov Contact Siemens ProductCERT for up-to-date information about the security of Siemens products or to report cybersecurity vulnerabilities at productcert@siemens.com. For support with increasing the security of installed Siemens PLCs, contact Siemens Industrial Cybersecurity Services at services.automation@siemens.com. See Siemens ProductCERT and Siemens CERT for more information. Appendix A: MITRE ATT&CK tactics and techniques See Table 1 for the threat actor tactics and techniques referenced in this advisory. Table 1: MITRE ATT&CK tactics and techniques Tactic Technique Title ID Use Reconnaissance Search Open Technical Databases: Scan Databases T1596.005 Using Internet scanning services to identify Internet-exposed or poorly segmented Siemens S7 Series PLCs Resource Development Develop Capabilities: Exploits T1587.004 Developing exploits for known Siemens S7 Series PLC vulnerabilities Resource Development Obtain Capabilities: Artificial Intelligence T1588.007 Rapidly iterating exploit code through AI-assisted development Execution Native API T0834 Deploying AI-generated Python scripts incorporating the snap7.dll library Execution Modify Controller Tasking T0821 Conducting write operations on data blocks, potentially for pre-positioning for effects operations Evasion Masquerading T0849 Masquerading as legitimate monitoring tools to evade detection Lateral Movement Insecure Credentials T1694 Accessing exposed devices that have unconfigured (default) or minimally configured authentication Collection Data from Local System T0893 Conducting read operations on data blocks, potentially for reconnaissance Appendix B: MITRE D3FEND countermeasures See Table 2 for a mapping of several of the cybersecurity countermeasures mentioned in this advisory. Table 2: MITRE D3FEND Countermeasures Countermeasure Title ID Description Hardware Component Inventory D3-HCI Conduct an immediate inventory of all Siemens S7 Series PLCs Software Update D3-SU Apply critical security patches as soon as possible Network Isolation D3-NI Verify network segmentation and ensure PLCs are not accessible from the Internet Network Access Mediation D3-NAM Restrict TIA Portal/STEP 7 access to authorized engineering workstations only via MAC/IP allowlisting on PLCs Credential Hardening D3-CH Enable PLC password protection on all S7 controllers Enable multi-factor authentication for all remote access to OT networks Platform Monitoring D3-PM Deploy ICS-aware intrusion detection Alert on unauthorized PUT/GET operations Monitor for unexpected behavior deviations Monitor for snap7.dll library imports Hunt for indicators of compromise Network Traffic Analysis D3-NTA Alert on unexpected S7comm traffic on TCP port 102 Watch for sequential IP scanning patterns Application Configuration Hardening D3-ACH Disable unused web servers and protocols Remove SNMP community strings Watch for ladder logic changes Notes 1 MITRE and ATT&CK are registered trademarks of The MITRE Corporation. MITRE D3FEND is a trademark of the MITRE Corporation.
· CISA Cybersecurity Advisory

Siemens Simcenter Nastran

View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions…
Read full source summary
View CSAF Summary Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Simcenter Nastran are affected: Simcenter Femap vers:intdot/<2606 (CVE-2026-59086) Simcenter Nastran vers:intdot/<2606 (CVE-2026-59086) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Simcenter Nastran Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing, Defense Industrial Base, Energy, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-59086 The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Simcenter Nastran Vendor: Siemens Product Version: Simcenter Femap < V2606, Simcenter Nastran < V2606 Product Status: known_affected Remediations Vendor fix Update to V2606 or later version https://support.sw.siemens.com/product/275652363/ Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Michael Heinzl reported this vulnerability to Siemens ProductCERT. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-069220 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Added Simcenter Femap with fix 2026-08-18 3 Initial CISA Republication of Siemens ProductCERT SSA-069220 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Malcolm

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or execute arbitrary code. The following versions of CISA Malcolm are affected: Malcolm <26.06.1 (CVE-2026-55676) Malcolm <26.07.0 (CVE-2026-63133, CVE-2026-63134, CVE-2026-63177) Malcolm <=26.07.1 (CVE-2026-19670, CVE-2026-19671) CVSS Vendor Equipment Vulnerabilities v3 8.8 CISA CISA…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or execute arbitrary code. The following versions of CISA Malcolm are affected: Malcolm <26.06.1 (CVE-2026-55676) Malcolm <26.07.0 (CVE-2026-63133, CVE-2026-63134, CVE-2026-63177) Malcolm <=26.07.1 (CVE-2026-19670, CVE-2026-19671) CVSS Vendor Equipment Vulnerabilities v3 8.8 CISA CISA Malcolm Allocation of Resources Without Limits or Throttling, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type, Incorrect Authorization, Improper Handling of Highly Compressed Data (Data Amplification) Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-63133 Malcolm is a network traffic analysis tool suite. Prior to version 26.07.0, safe-extract.py extracts uploaded archives with no limit on entry count, directory depth, total entries, or output size. A small malicious archive containing a large number of directory or file entries causes the filebeat processing container to create an unbounded number of filesystem objects, exhausting inodes or filesystem metadata and denying service to the processing pipeline and any service sharing the same mount. Version 26.07.0 fixes the issue. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <26.07.0 Product Status: known_affected Remediations Vendor fix Malcolm version 26.07.0 addresses these issues. For more information, see https://github.com/cisagov/Malcolm/pull/1043. (CVE-2026-63133, CVE-2026-63134, CVE-2026-63177) https://github.com/cisagov/Malcolm/pull/1043 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-63134 Malcolm is a network traffic analysis tool suite. Prior to version 26.07.0, safe-extract.py protects file extraction with libarchive's secure flags, but creates directory entries with a raw os.makedirs(os.path.join(dest, entry.pathname)) that has no traversal protection. An uploaded malicious archive containing a directory entry with a ../ sequence or an absolute path causes the filebeat processing container to create directories outside the intended extraction directory. Version 26.07.0 fixes the issue. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <26.07.0 Product Status: known_affected Remediations Vendor fix Malcolm version 26.07.0 addresses these issues. For more information, see https://github.com/cisagov/Malcolm/pull/1043. (CVE-2026-63133, CVE-2026-63134, CVE-2026-63177) https://github.com/cisagov/Malcolm/pull/1043 Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N CVE-2026-55676 Malcolm is a network traffic analysis tool suite. The file-upload component (FilePond PHP backend) accepts uploads at POST /server/php/submit.php and stores them in a directory served by the same nginx and php-fpm instance. The allow-list that should restrict accepted file types is an empty array by default (file-upload/php/config.php:16), so the type check is a no-op and every extension is accepted. The filename sanitizer keeps the .php extension intact. Committed files land in /var/www/upload/server/php/files (file-upload/php/config.php:7), and the component's nginx routes any URL ending in .php to php-fpm. An authenticated GET /server/php/files/.php then executes the uploaded code as www-data. Prior to version 26.06.1, in RBAC mode, the upload endpoint is reachable by the granular ROLE_UPLOAD role (nginx/lua/nginx_auth_helpers.lua:71), a role intended only for submitting capture files. As a result, a user holding the upload-only role runs arbitrary PHP as www-data inside the file-upload container. Version 26.06.1 fixes the issue. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <26.06.1 Product Status: known_affected Remediations Vendor fix Malcolm version 26.06.1 addresses this issue. For more information, see https://github.com/cisagov/Malcolm/pull/1026. (CVE-2026-55676) https://github.com/cisagov/Malcolm/pull/1026 Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-63177 Malcolm is a network traffic analysis tool suite. Prior to version 26.07.0, role-based access control enforced in the Nginx OpenResty Lua layer evaluates the raw, unnormalized ngx.var.request_uri, while Nginx itself routes requests using the normalized path. An authenticated low-privilege user can prepend a traversal segment (for example /x/../upload/...) so that Nginx routes the request to a restricted backend while the Lua role check fails to match any rule and falls open, granting access it should deny. Version 26.07.0 fixes the issue. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <26.07.0 Product Status: known_affected Remediations Vendor fix Malcolm version 26.07.0 addresses these issues. For more information, see https://github.com/cisagov/Malcolm/pull/1043. (CVE-2026-63133, CVE-2026-63134, CVE-2026-63177) https://github.com/cisagov/Malcolm/pull/1043 Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:L/SI:L/SA:L CVE-2026-19670 Malcolm's nginx Lua role-based access control (RBAC) layer decides whether an authenticated user may reach a role-restricted path (e.g. /htadmin, /auth, /admin_login, /arkime/api/esadmin, NetBox, upload endpoints) by pattern-matching the raw, percent-encoded request URI. Nginx itself, however, selects which location block actually serves the request using the percent-decoded, normalized URI. Because the RBAC check never percent-decodes its input, an authenticated low-privilege user can request an admin-only path using percent-encoding (e.g. /%68tadmin.php) and have nginx route it to the restricted location while the Lua RBAC gate evaluating the un-decoded raw string finds no matching restriction and grants access. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <=26.07.1 Product Status: known_affected Remediations Vendor fix Malcolm version 26.08.0 addresses this issue. For more information, see https://github.com/cisagov/Malcolm/security/advisories/GHSA-jr6p-63pg-hr6g. (CVE-2026-19670) https://github.com/cisagov/Malcolm/security/advisories/GHSA-jr6p-63pg-hr6g Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-19671 Malcolm's upload-processing pipeline (scripts/safe-extract.py) enforces entry-count, nesting-depth, and total-uncompressed-byte limits when extracting container archives (zip/tar/rar/7z via libarchive), but those limits are not applied when the uploaded file is a single-stream compressed format (.gz, .bz2, .xz, .lzma, .lz) that isn't a .tar.*-style archive. Any authenticated user permitted to upload PCAP/log files can upload a small, highly compressible file (e.g. a gzip bomb) that decompresses to an effectively unbounded size on disk, exhausting the shared Docker volume used by OpenSearch, Logstash, Arkime, and Zeek, and disrupting the platform for all users. View CVE Details Affected Products CISA Malcolm Vendor: CISA Product Version: CISA Malcolm: <=26.07.1 Product Status: known_affected Remediations Vendor fix Malcolm version 26.08.0 addresses this issue. For more information, see https://github.com/cisagov/Malcolm/security/advisories/GHSA-f2v6-8cj4-mhr6. (CVE-2026-19671) https://github.com/cisagov/Malcolm/security/advisories/GHSA-f2v6-8cj4-mhr6 Relevant CWE: CWE-409 Improper Handling of Highly Compressed Data (Data Amplification) Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments pavanchow reported CVE-2026-63133, CVE-2026-63134, and CVE-2026-63177 to CISA. kah-ja, DeathRipper21 reported CVE-2026-55676 to CISA. tinyb0y reported CVE-2026-19670 and CVE-2026-19671 to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-18 Date Revision Summary 2026-08-18 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33824 Microsoft Internet Key Exchange (IKE) Service Extensions Double Free Vulnerability CVE-2026-55040 Microsoft SharePoint Weak Authentication Vulnerability CVE-2026-59310 Broadcom VMware vCenter Path Traversal Vulnerability CVE-2026-65400 Apple macOS Improper…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33824 Microsoft Internet Key Exchange (IKE) Service Extensions Double Free Vulnerability CVE-2026-55040 Microsoft SharePoint Weak Authentication Vulnerability CVE-2026-59310 Broadcom VMware vCenter Path Traversal Vulnerability CVE-2026-65400 Apple macOS Improper Authentication Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-62593 Ray-Project Ray Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-62593 Ray-Project Ray Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Siemens Solid Edge

View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge…
Read full source summary
View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge are affected: Solid Edge SE2025 vers:intdot/<225.0.15 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) Solid Edge SE2026 vers:intdot/<226.0.7 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Out-of-bounds Read, Out-of-bounds Write, Use After Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50058 The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50059 The affected applications contains an out of bounds write vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50060 The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50061 The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50062 The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50063 The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50064 The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-621657 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-621657 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens License Server (SLS)

View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1,…
Read full source summary
View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1, vers:intdot/<5.3 (CVE-2026-69108, CVE-2026-69109) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens License Server (SLS) Incorrect Permission Assignment for Critical Resource, Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-69108 The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise. View CVE Details Affected Products Siemens License Server (SLS) Vendor: Siemens Product Version: Siemens License Server (SLS) < V5.1 Product Status: known_affected Remediations Vendor fix Update to V5.1 or later version https://support.sw.siemens.com/product/1586485382/ Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N CVE-2026-69109 The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application. View CVE Details Affected Products Siemens License Server (SLS) Vendor: Siemens Product Version: Siemens License Server (SLS) < V5.3 Product Status: known_affected Remediations Vendor fix Update to V5.3 or later version https://support.sw.siemens.com/product/1586485382/ Relevant CWE: CWE-35 Path Traversal: '.../...//' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-077553 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-077553 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo…
Read full source summary
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC3 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC4 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E003 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E24 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC7 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) CVSS Vendor Equipment Vulnerabilities v3 4.3 Siemens Siemens Desigo DXR and PXC Controllers Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-59693 The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality. View CVE Details Affected Products Siemens Desigo DXR and PXC Controllers Vendor: Siemens Product Version: Desigo DXR2 < V01.21.233.16-7862, Desigo PXC3 < V01.21.233.16-7862, Desigo PXC4 < V02.21.194.36-2715, Desigo PXC5.E003 < V02.21.194.36-2715, Desigo PXC5.E24 < V02.21.194.36-2715, Desigo PXC7 < V02.21.194.36-2715 Product Status: known_affected Remediations Vendor fix Update to V01.21.233.16-7862 or later version Please contact your local Siemens office for additional support in obtaining the update. Vendor fix Update to V02.21.194.36-2715 or later version Please contact your local Siemens office for additional support in obtaining the update. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L Acknowledgments Thomas EBI of Sauter reported this vulnerability to Siemens General Recommendations As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-781903 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens SSA-781903 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls Inc. Airwall

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of Hard-coded Cryptographic Key, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-64887 A hardcoded password or cryptographic key was identified in the Airwall application. A hardcoded credential leads to a significant authentication failure that can be difficult for system or application administrators to detect. Once discovered, it is difficult to remediate without manually modifying or patching the software. The hardcoded key is identical across all installations of the product and across all customer organizations, meaning a single disclosure of the key - common on the internet - grants any knowledgeable attacker access to all affected deployments. An attacker with access to application code or binary files can use the hardcoded key to decrypt sensitive application data stored in configuration and database files, enabling further data disclosure or compromise of application infrastructure. View CVE Details Affected Products Johnson Controls Inc. Airwall Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. Airwall: <=4.0.4 Product Status: known_affected Remediations Mitigation To help reduce risk of exploitation, Johnson Controls recommends the following defensive measures: Apply v4.1.0 or later patches for all Airwalls. Mitigation Store all cryptographic keys in a secure key management system (KMS) or hardware security module (HSM) rather than embedding them in source code or configuration files. (CVE-2026-64887) Mitigation Implement a regular key rotation policy to limit the exposure window if a key is compromised. (CVE-2026-64887) Mitigation Use unique cryptographic keys per device, installation, or deployment instance to prevent a single compromised key from affecting all installations. (CVE-2026-64887) Mitigation Remove any hard-coded keys from source code repositories and binaries, replacing them with references to secure external key stores. (CVE-2026-64887)Apply the principle of least privilege to key access, ensuring only authorized processes and personnel can retrieve cryptographic material. (CVE-2026-64887) Mitigation Use static analysis and secrets-scanning tools in CI/CD pipelines to detect and prevent hard-coded keys from being committed to source control. (CVE-2026-64887) Mitigation Encrypt keys at rest and in transit and ensure key-wrapping mechanisms are in place for any keys stored on disk. (CVE-2026-64887) Mitigation Audit and monitor access to cryptographic keys, logging all retrieval and usage events for anomaly detection. (CVE-2026-64887) Mitigation Refer to and follow all steps in the product hardening guide or the JCI universal hardening guide found here https://www.johnsoncontrols.com/trust-center/cybersecurity/resources (CVE-2026-64887) https://www.johnsoncontrols.com/trust-center/cybersecurity/resources Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-25 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories (CVE-2026-64887) https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-34492 An arbitrary file read vulnerability was identified in the Airwall application. This issue occurs when user-supplied input is directly incorporated into filesystem access functions without adequate validation or sanitization. As a result, an attacker can request and obtain the contents of arbitrary files on the server, including sensitive configuration files, source code, credential stores, and private keys, provided the application process has permission to read them. The vulnerability is commonly exploited through path traversal sequences (e.g., ../) or absolute file paths (e.g., /etc/passwd). Encoding variations of traversal sequences (e.g., %2e%2e%2f) can also bypass basic filters. View CVE Details Affected Products Johnson Controls Inc. Airwall Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. Airwall: <=4.0.4 Product Status: known_affected Remediations Mitigation To help reduce risk of exploitation, Johnson Controls recommends the following defensive measures: Apply v4.1.0 or later patches for all Airwalls. Mitigation Validate and sanitize all user-supplied input before using it in file system operations (CVE-2026-34492) Mitigation Implement strict allowlists for permitted file paths, file names, and directories (CVE-2026-34492) Mitigation Use canonicalization to resolve path traversal sequences before validation (CVE-2026-34492) Mitigation Apply the principle of least privilege to the application file system access permissions (CVE-2026-34492) Mitigation Deploy sandboxing or chroot jails to restrict the application's file system scope (CVE-2026-34492) Mitigation Avoid passing user-controlled data directly to file system APIs (CVE-2026-34492) Mitigation Refer to and follow all steps in the product hardening guide or the JCI universal hardening guide found here https://www.johnsoncontrols.com/trust-center/cybersecurity/resources (CVE-2026-34492) https://www.johnsoncontrols.com/trust-center/cybersecurity/resources Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-18 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories (CVE-2026-34492) https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L 4.0 5.9 MEDIUM CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Johnson Controls reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this (these) vulnerability(ies) has been reported to CISA at this time. This (these) vulnerability(ies) is (are) not exploitable remotely. This (these) vulnerability(ies) has (have) a high attack complexity. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Republication of Johnson Controls JCI-PSA-2026-18 and JCI-PSA-2026-25 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls Metasys

View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491)…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor Equipment Vulnerabilities v3 8 Johnson Controls Inc Johnson Controls Metasys Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-34491 A low-privilege user can inject a malicious XSS payload into the Metasys UI via a crafted URL. The payload persists across logins and executes in the browser context of other users, including administrators. View CVE Details Affected Products Johnson Controls Metasys Vendor: Johnson Controls Inc Product Version: Johnson Controls Inc Metasys 12: vers:all/*, Johnson Controls Inc Metasys 13: vers:all/*, Johnson Controls Inc Metasys 14: <v14.1.5, Johnson Controls Inc Metasys 15: <v15.0.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following actions: Mitigation User are recommended to apply the latest available patches for affected Metasys versions Mitigation Metasys 16.0: Not impacted, fixed prior to release Vendor fix Metasys 15.0: Patch released 2026-03-25 Vendor fix Metasys 14.1.5: Forecast release 2026-07-15 Vendor fix Metasys 13: End of support, update to later version Vendor fix Metasys 12: End of support, update to later version Mitigation Metasys 11 & prior: Not affected (vulnerability introduced at version 12) Mitigation To help reduce the risk of exploitation, we suggest considering the following defensive measures: Mitigation Upgrade to Metasys version 16.0 or apply the latest available patch for your version (15.0.1 or 14.1.5 when available) Mitigation Restrict network access to the Metasys UI to trusted networks and users only; do not expose the interface directly to the internet Mitigation Implement network segmentation to isolate building automation systems from the corporate IT network Mitigation Enforce least-privilege access controls – limit user accounts to the minimum permissions necessary Mitigation Implement Content Security Policy (CSP) headers and other HTTP security headers where possible at the network/proxy level Mitigation Monitor for suspicious URL patterns and unexpected script execution in Metasys UI access logs Mitigation Use a web application firewall (WAF) in front of the Metasys UI to detect and block common XSS payloads Mitigation Educate users to avoid clicking on untrusted or unexpected links that target the Metasys UI Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-11 at the following location: Security Advisories. Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H 4.0 8.6 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments An anonymous researcher reported this vulnerability to Johnson Controls Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication. Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Siveillance Video

View CSAF Summary Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video are affected: Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014) Siveillance Video V2024 R1 vers:intdot/<24.1.16…
Read full source summary
View CSAF Summary Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video are affected: Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014) Siveillance Video V2024 R1 vers:intdot/<24.1.16 (CVE-2026-3014) Siveillance Video V2025 vers:intdot/<25.1.15 (CVE-2026-3014) CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens Siveillance Video Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Communications, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-3014 Milestone has released a new version of XProtect® (and several cumulative patch updates) which fix security vulnerability in Management Server API. The vulnerability causes users with edit permissions to the Management Server to be able to execute arbitrary code in context of the Management Server Service. View CVE Details Affected Products Siemens Siveillance Video Vendor: Siemens Product Version: Siveillance Video V2023 R3 < V23.3.27, Siveillance Video V2024 R1 < V24.1.16, Siveillance Video V2025 < V25.1.15 Product Status: known_affected Remediations Vendor fix Update to V23.3 HotfixRev27 or later version https://support.industry.siemens.com/cs/ww/en/view/109827783/ Vendor fix Update to V24.1 HotfixRev16 or later version https://support.industry.siemens.com/cs/ww/en/view/109976123/ Vendor fix Update to V25.1 HotfixRev15 or later version https://support.industry.siemens.com/cs/ww/en/view/109988670/ Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H Acknowledgments Milestone PSIRT reported this vulnerability to Siemens General Recommendations As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment. Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-825228 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens SSA-825228 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Flow Neuroscience FL-100

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-18164 An undocumented hard-coded credential, shared by all device units, is authorized to bypass authentication. This allows an attacker within Bluetooth range to arbitrarilymanipulate brain stimulation parameters and state. View CVE Details Affected Products Flow Neuroscience FL-100 Vendor: Flow Neuroscience Product Version: Flow Neuroscience Flow Neuroscience FL-100: <July_2026, Flow Neuroscience Halo Neuroscience FL-100: <July_2026 Product Status: known_affected Remediations Mitigation Users are encouraged to install the latest firmware updates provided by Flow Neuroscience via the Flow app. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 4.0 7.2 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments A.C. Buglione reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens LOGO! Soft Comfort

View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful…
Read full source summary
View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive project logic and configurations. Siemens has released a new version for LOGO! Soft Comfort and recommends to update to the latest version. The following versions of Siemens LOGO! Soft Comfort are affected: LOGO! Soft Comfort vers:intdot/<9 (CVE-2026-57262, CVE-2026-57263) CVSS Vendor Equipment Vulnerabilities v3 6.8 Siemens Siemens LOGO! Soft Comfort Use of Hard-coded Cryptographic Key, Use of a One-Way Hash without a Salt Background Critical Infrastructure Sectors: Commercial Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-57262 Affected products use a static, hardcoded AES master key to encrypt project files. This could allow a local attacker to extract the master key from the application files or memory and use it to decrypt project files or remove project passwords entirely without knowing the actual user-defined password. View CVE Details Affected Products Siemens LOGO! Soft Comfort Vendor: Siemens Product Version: LOGO! Soft Comfort < V9 Product Status: known_affected Remediations Vendor fix Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present. Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N CVE-2026-57263 The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash. View CVE Details Affected Products Siemens LOGO! Soft Comfort Vendor: Siemens Product Version: LOGO! Soft Comfort < V9 Product Status: known_affected Remediations Vendor fix Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present. Relevant CWE: CWE-759 Use of a One-Way Hash without a Salt Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-751328 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-751328 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ANDRITZ HIPASE-250 and 250 SCALA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: HIPASE-250 <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) 250 SCALA <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: HIPASE-250 <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) 250 SCALA <=7.20 (CVE-2026-65309, CVE-2026-65310, CVE-2026-65311, CVE-2026-65313) CVSS Vendor Equipment Vulnerabilities v3 8.1 ANDRITZ ANDRITZ HIPASE-250 and 250 SCALA Storing Passwords in a Recoverable Format, Missing Authentication for Critical Function, Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Austria Vulnerabilities Expand All + CVE-2026-65309 ANDRITZ HIPASE-250 (formerly 250 SCALA) in affected versions stores and transmits user passwords using a reversible format instead of a one-way password hash. This allows an attacker able to read the credential store or capture network traffic to recover all stored passwords. View CVE Details Affected Products ANDRITZ HIPASE-250 and 250 SCALA Vendor: ANDRITZ Product Version: ANDRITZ HIPASE-250: <=7.20, ANDRITZ 250 SCALA: <=7.20 Product Status: known_affected Remediations Vendor fix ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact https://www.andritz.com/group-en/contact Relevant CWE: CWE-257 Storing Passwords in a Recoverable Format Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-65310 ANDRITZ HIPASE-250 (formerly 250 SCALA), in the default configuration of affected versions, exposes its data and configuration endpoint without any authentication and permissive CORS on every response. An unauthenticated attacker with network access can read live process values and server configuration. View CVE Details Affected Products ANDRITZ HIPASE-250 and 250 SCALA Vendor: ANDRITZ Product Version: ANDRITZ HIPASE-250: <=7.20, ANDRITZ 250 SCALA: <=7.20 Product Status: known_affected Remediations Vendor fix ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact https://www.andritz.com/group-en/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-65311 The HTTP server component of ANDRITZ HIPASE-250 (formerly 250 SCALA) in affected versions exposes an undocumented endpoint that changes the server's logging level and target without requiring authentication. A remote, unauthenticated attacker with network access to the service may suppress audit logging, potentially concealing other activity on the system. View CVE Details Affected Products ANDRITZ HIPASE-250 and 250 SCALA Vendor: ANDRITZ Product Version: ANDRITZ HIPASE-250: <=7.20, ANDRITZ 250 SCALA: <=7.20 Product Status: known_affected Remediations Vendor fix ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact https://www.andritz.com/group-en/contact Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-65313 A provisioning script used when installing HIPASE-250 (formerly 250 SCALA) engineering workstations sets a fixed, hard-coded x11vnc password. Because the same credential is applied to every workstation provisioned this way, an attacker with adjacent-network access who knows the password can gain VNC access to affected workstations. View CVE Details Affected Products ANDRITZ HIPASE-250 and 250 SCALA Vendor: ANDRITZ Product Version: ANDRITZ HIPASE-250: <=7.20, ANDRITZ 250 SCALA: <=7.20 Product Status: known_affected Remediations Vendor fix ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact https://www.andritz.com/group-en/contact Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N 4.0 8.6 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Duc Anh Nguyen and Ta Duc Thien of NTCS OT Penetration Testing Team reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Simcenter Femap

View CSAF Summary Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest…
Read full source summary
View CSAF Summary Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version. The following versions of Siemens Simcenter Femap are affected: Simcenter Femap vers:intdot/<2606.0001 (CVE-2026-59700, CVE-2026-59701) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Simcenter Femap Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-59700 The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Simcenter Femap Vendor: Siemens Product Version: Simcenter Femap < V2606.0001 Product Status: known_affected Remediations Vendor fix Update to V2606.0001 or later version https://support.sw.siemens.com/product/275652363/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-59701 The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Simcenter Femap Vendor: Siemens Product Version: Simcenter Femap < V2606.0001 Product Status: known_affected Remediations Vendor fix Update to V2606.0001 or later version https://support.sw.siemens.com/product/275652363/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-584312 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-584312 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AVEVA Enterprise SCADA

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639) Enterprise SCADA HMI 2024|2024|R2 (CVE-2025-7639) Enterprise SCADA HMI <=2023_P1 (CVE-2025-7639) CVSS Vendor Equipment Vulnerabilities v3 7.1 AVEVA AVEVA Enterprise SCADA Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-7639 The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps". View CVE Details Affected Products AVEVA Enterprise SCADA Vendor: AVEVA Product Version: AVEVA Enterprise SCADA: 2025, AVEVA Enterprise SCADA: >=2024|<=2024_SP1_P01, AVEVA Enterprise SCADA: >=2023|<=2023_SP1, AVEVA Enterprise SCADA: >=2022|<=2022_SP2_P2, AVEVA Enterprise SCADA: <=2021_SP2_P5, AVEVA Enterprise SCADA HMI: 2024|2024_R2, AVEVA Enterprise SCADA HMI: <=2023_P1 Product Status: known_affected Remediations Mitigation AVEVA recommends that customers using affected product versions should perform the following to mitigate the risk of exploit: 1. Evaluate the impact of these vulnerabilities based on your operational environment, architecture, and product implementation. 2. Plan an upgrade of Servers and Clients to one of the available fixed versions listed in this document. 3. Configure Servers and Clients as described in this document. Mitigation Contact your AVEVA Technical Support representative, Customer Success Manager, Account Manager, or Solution Integrator to obtain the security update best applicable to the product version currently deployed in your environment: Servers: AVEVA Enterprise SCADA v2025 P1 or higher, AVEVA Enterprise SCADA v2024 SP1 P2, AVEVA Enterprise SCADA v2023 SP1 P1, AVEVA Enterprise SCADA v2022 SP2 P3, AVEVA Enterprise SCADA v2021 SP2 P6, AVEVA Pipeline Operations for Gas/Liquids v2025 P1 or higher, AVEVA Pipeline Operations for Gas/Liquids v2024 SP1 P2, AVEVA Pipeline Operations for Gas/Liquids v2023 SP1 P1, AVEVA Pipeline Operations for Gas/Liquids v2022 SP2 P3, AVEVA Pipeline Operations for Gas/Liquids v2021 SP2 P6 Clients: AVEVA Enterprise SCADA HMI v2024 R2 HF7 or higher, AVEVA Enterprise SCADA HMI v2024 P1, AVEVA Enterprise SCADA HMI v2023 P2 HF1, AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media) v2025 SP1 P2 or higher, AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media) v2025 SP1 P2 or higher, Measurement Advisor 2025 P1 or higher, Measurement Advisor 2021 SP1 HF16 Mitigation To fully mitigate the risk of exploit, the following configuration changes must be implemented after all server and client nodes have been upgraded to compatible versions that support the fix:Server Components: Change "BinarySerializer" -> "Mode" setting from 'Binary Formatter' to 'Json'. Change "BinarySerializer" -> "AcceptBinaryFormattedData" setting from 'true' to 'false'. Re-cache the XOS Event Handlers assembly Mitigation Client Components: Configure clients/products that interface with Enterprise SCADA to only use JSON serialization. Mitigation HMI: Migrate HMI displays Mitigation For step-by-step instructions on where and how to apply these configuration settings, how to migrate HMI displays, compatible server-client versions list, and additional details please refer to KB117814 "AVEVA Midstream Product Bulletin - Removal of Binary Formatter" https://softwaresupportsp.aveva.com/en-US/knowledge/details/000117814?lang=en_US Mitigation AVEVA recommends the following general defensive measures: Audit devices, network topology, and perimeter defences to ensure all applicable security best practices from AVEVA's Enterprise SCADA Reference System Architecture are adhered to. Audit assigned permissions to ensure that only trusted users are given "DNA Authority - Operator" rights: https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html Disallow BLT Test clients in production environmentsFor additional details on defensive measures, refer to Section 5 of KB117814 "AVEVA Midstream Product Bulletin - Removal of Binary Formatter https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html Mitigation For more information on this vulnerability, including security updates, users should see the security bulletin AVEVA-2026-005. https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-005.pdf Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H 4.0 6.1 MEDIUM CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments AVEVA reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks. Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Republication of AVEVA security bulletin AVEVA-2026-005 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy APM Edge Product

View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge…
Read full source summary
View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026-43500) CVSS Vendor Equipment Vulnerabilities v3 8.8 Hitachi Energy Hitachi Energy APM Edge Product Write-what-where Condition, Out-of-bounds Write Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-43284 CWE-123: Write-what-where Condition A vulnerability exists in the IPsec ESP subsystem (esp4, esp6) of the Linux kernel used in APM Edge that allows a local unprivileged user to escalate privileges to root. The flaw exists in how the kernel handles memory pages when processing ESP encrypted network packets. An attacker can craft a packet that causes the kernel to decrypt data directly into memory pages it does not own, including the cached copies of privileged operating system binaries. When one of those binaries is executed, the attacker's injected code runs with root privileges. In APM Edge, the vulnerable kernel modules (esp4, esp6) can be loaded by any local user and exploited. View CVE Details Affected Products Hitachi Energy APM Edge Product Vendor: Hitachi Energy Product Version: APM Edge versions 6.10 and prior Product Status: known_affected Remediations Mitigation Disable the esp4 and esp6 modules [2] Relevant CWE: CWE-123 Write-what-where Condition Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2026-43500 CWE-787: Out-of-bounds Write A vulnerability exists in the RxRPC protocol implementation of Linux kernel used in APM Edge that allows a local unprivileged user to escalate privileges to root. RxRPC incorrectly processes incoming network packets that carry externally owned memory fragments. During packet processing, the kernel writes decrypted data directly into memory pages it does not own, including cached copies of privileged operating system binaries. Upon execution of a corrupted binary, the attacker's injected code runs with root privileges. In APM Edge, the vulnerable kernel module (rxrpc) can be loaded by any local user and exploited. View CVE Details Affected Products Hitachi Energy APM Edge Product Vendor: Hitachi Energy Product Version: APM Edge versions 6.10 and prior Product Status: known_affected Remediations Mitigation Disable the rxrpc module [2] Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Hitachi Energy Internal Team reported these vulnerabilities to CISA Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Additional information on Industrial Control Systems Cybersecurity Best Practices can be found in the Hitachi Energy “Industrial Control Systems Cybersecurity Best Practices” Cybersecurity Notification. [1] SSVC SSVCv2/E:N/A:N/2026-07-24T07:30:06Z/ Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000256 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-28 Date Revision Summary 2026-07-28 1 Initial public release 2026-08-13 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000256 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Haiwell IoT Cloud HMI Gateway

View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-19188 A critical OS command injection vulnerability has been identified in the Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the Net Check feature accessible via the /setting endpoint. The cmdPing Socket.io event fails to properly sanitize user-supplied input before passing it to the underlying operating system, allowing an attacker to inject and execute arbitrary OS commands with root privileges View CVE Details Affected Products Haiwell IoT Cloud HMI Gateway Vendor: Haiwell Product Version: Haiwell Haiwell IoT Cloud HMI Gateway: 3.40.1.12 Product Status: known_affected Remediations Mitigation Haiwell has addressed the issue in patch version number Scada-v3.50.1.19, which is available for download on their website: https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361 https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Fiqram Akmal reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Parasolid

View CSAF Summary Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Parasolid are affected: Parasolid V38.0…
Read full source summary
View CSAF Summary Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Parasolid are affected: Parasolid V38.0 vers:intdot/<38.0.235 (CVE-2026-64629) Parasolid V38.1 vers:intdot/<38.1.230 (CVE-2026-64629) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Parasolid Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-64629 The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Parasolid Vendor: Siemens Product Version: Parasolid V38.0 < V38.0.235, Parasolid V38.1 < V38.1.230 Product Status: known_affected Remediations Vendor fix Update to V38.0.235 or later version https://support.sw.siemens.com/product/258316782/ Vendor fix Update to V38.1.230 or later version https://support.sw.siemens.com/product/258316782/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-138516 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-138516 advisory Legal Notice and Terms of Use