30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-62593 Ray-Project Ray Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-62593 Ray-Project Ray Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Siemens LOGO! Soft Comfort

View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful…
Read full source summary
View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive project logic and configurations. Siemens has released a new version for LOGO! Soft Comfort and recommends to update to the latest version. The following versions of Siemens LOGO! Soft Comfort are affected: LOGO! Soft Comfort vers:intdot/<9 (CVE-2026-57262, CVE-2026-57263) CVSS Vendor Equipment Vulnerabilities v3 6.8 Siemens Siemens LOGO! Soft Comfort Use of Hard-coded Cryptographic Key, Use of a One-Way Hash without a Salt Background Critical Infrastructure Sectors: Commercial Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-57262 Affected products use a static, hardcoded AES master key to encrypt project files. This could allow a local attacker to extract the master key from the application files or memory and use it to decrypt project files or remove project passwords entirely without knowing the actual user-defined password. View CVE Details Affected Products Siemens LOGO! Soft Comfort Vendor: Siemens Product Version: LOGO! Soft Comfort < V9 Product Status: known_affected Remediations Vendor fix Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present. Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N CVE-2026-57263 The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash. View CVE Details Affected Products Siemens LOGO! Soft Comfort Vendor: Siemens Product Version: LOGO! Soft Comfort < V9 Product Status: known_affected Remediations Vendor fix Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present. Relevant CWE: CWE-759 Use of a One-Way Hash without a Salt Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-751328 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-751328 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Flow Neuroscience FL-100

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-18164 An undocumented hard-coded credential, shared by all device units, is authorized to bypass authentication. This allows an attacker within Bluetooth range to arbitrarilymanipulate brain stimulation parameters and state. View CVE Details Affected Products Flow Neuroscience FL-100 Vendor: Flow Neuroscience Product Version: Flow Neuroscience Flow Neuroscience FL-100: <July_2026, Flow Neuroscience Halo Neuroscience FL-100: <July_2026 Product Status: known_affected Remediations Mitigation Users are encouraged to install the latest firmware updates provided by Flow Neuroscience via the Flow app. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 4.0 7.2 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments A.C. Buglione reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Solid Edge

View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge…
Read full source summary
View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge are affected: Solid Edge SE2025 vers:intdot/<225.0.15 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) Solid Edge SE2026 vers:intdot/<226.0.7 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Out-of-bounds Read, Out-of-bounds Write, Use After Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50058 The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50059 The affected applications contains an out of bounds write vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50060 The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50061 The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50062 The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50063 The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2026-50064 The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge SE2025 < V225.0.15, Solid Edge SE2026 < V226.0.7 Product Status: known_affected Remediations Vendor fix Update to V225.0 Update 15 or later version https://support.sw.siemens.com/product/246738425/ Vendor fix Update to V226.0 Update 7 or later version https://support.sw.siemens.com/product/246738425/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-621657 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-621657 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls Metasys

View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491)…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491) Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor Equipment Vulnerabilities v3 8 Johnson Controls Inc Johnson Controls Metasys Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-34491 A low-privilege user can inject a malicious XSS payload into the Metasys UI via a crafted URL. The payload persists across logins and executes in the browser context of other users, including administrators. View CVE Details Affected Products Johnson Controls Metasys Vendor: Johnson Controls Inc Product Version: Johnson Controls Inc Metasys 12: vers:all/*, Johnson Controls Inc Metasys 13: vers:all/*, Johnson Controls Inc Metasys 14: <v14.1.5, Johnson Controls Inc Metasys 15: <v15.0.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following actions: Mitigation User are recommended to apply the latest available patches for affected Metasys versions Mitigation Metasys 16.0: Not impacted, fixed prior to release Vendor fix Metasys 15.0: Patch released 2026-03-25 Vendor fix Metasys 14.1.5: Forecast release 2026-07-15 Vendor fix Metasys 13: End of support, update to later version Vendor fix Metasys 12: End of support, update to later version Mitigation Metasys 11 & prior: Not affected (vulnerability introduced at version 12) Mitigation To help reduce the risk of exploitation, we suggest considering the following defensive measures: Mitigation Upgrade to Metasys version 16.0 or apply the latest available patch for your version (15.0.1 or 14.1.5 when available) Mitigation Restrict network access to the Metasys UI to trusted networks and users only; do not expose the interface directly to the internet Mitigation Implement network segmentation to isolate building automation systems from the corporate IT network Mitigation Enforce least-privilege access controls – limit user accounts to the minimum permissions necessary Mitigation Implement Content Security Policy (CSP) headers and other HTTP security headers where possible at the network/proxy level Mitigation Monitor for suspicious URL patterns and unexpected script execution in Metasys UI access logs Mitigation Use a web application firewall (WAF) in front of the Metasys UI to detect and block common XSS payloads Mitigation Educate users to avoid clicking on untrusted or unexpected links that target the Metasys UI Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-11 at the following location: Security Advisories. Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H 4.0 8.6 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments An anonymous researcher reported this vulnerability to Johnson Controls Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication. Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

AVEVA Enterprise SCADA

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA >=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639) Enterprise SCADA HMI 2024|2024|R2 (CVE-2025-7639) Enterprise SCADA HMI <=2023_P1 (CVE-2025-7639) CVSS Vendor Equipment Vulnerabilities v3 7.1 AVEVA AVEVA Enterprise SCADA Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-7639 The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps". View CVE Details Affected Products AVEVA Enterprise SCADA Vendor: AVEVA Product Version: AVEVA Enterprise SCADA: 2025, AVEVA Enterprise SCADA: >=2024|<=2024_SP1_P01, AVEVA Enterprise SCADA: >=2023|<=2023_SP1, AVEVA Enterprise SCADA: >=2022|<=2022_SP2_P2, AVEVA Enterprise SCADA: <=2021_SP2_P5, AVEVA Enterprise SCADA HMI: 2024|2024_R2, AVEVA Enterprise SCADA HMI: <=2023_P1 Product Status: known_affected Remediations Mitigation AVEVA recommends that customers using affected product versions should perform the following to mitigate the risk of exploit: 1. Evaluate the impact of these vulnerabilities based on your operational environment, architecture, and product implementation. 2. Plan an upgrade of Servers and Clients to one of the available fixed versions listed in this document. 3. Configure Servers and Clients as described in this document. Mitigation Contact your AVEVA Technical Support representative, Customer Success Manager, Account Manager, or Solution Integrator to obtain the security update best applicable to the product version currently deployed in your environment: Servers: AVEVA Enterprise SCADA v2025 P1 or higher, AVEVA Enterprise SCADA v2024 SP1 P2, AVEVA Enterprise SCADA v2023 SP1 P1, AVEVA Enterprise SCADA v2022 SP2 P3, AVEVA Enterprise SCADA v2021 SP2 P6, AVEVA Pipeline Operations for Gas/Liquids v2025 P1 or higher, AVEVA Pipeline Operations for Gas/Liquids v2024 SP1 P2, AVEVA Pipeline Operations for Gas/Liquids v2023 SP1 P1, AVEVA Pipeline Operations for Gas/Liquids v2022 SP2 P3, AVEVA Pipeline Operations for Gas/Liquids v2021 SP2 P6 Clients: AVEVA Enterprise SCADA HMI v2024 R2 HF7 or higher, AVEVA Enterprise SCADA HMI v2024 P1, AVEVA Enterprise SCADA HMI v2023 P2 HF1, AVEVA Pipeline Integrity Monitor (delivered on Pipeline Simulation media) v2025 SP1 P2 or higher, AVEVA Pipeline Training Simulator (delivered on Pipeline Simulation media) v2025 SP1 P2 or higher, Measurement Advisor 2025 P1 or higher, Measurement Advisor 2021 SP1 HF16 Mitigation To fully mitigate the risk of exploit, the following configuration changes must be implemented after all server and client nodes have been upgraded to compatible versions that support the fix:Server Components: Change "BinarySerializer" -> "Mode" setting from 'Binary Formatter' to 'Json'. Change "BinarySerializer" -> "AcceptBinaryFormattedData" setting from 'true' to 'false'. Re-cache the XOS Event Handlers assembly Mitigation Client Components: Configure clients/products that interface with Enterprise SCADA to only use JSON serialization. Mitigation HMI: Migrate HMI displays Mitigation For step-by-step instructions on where and how to apply these configuration settings, how to migrate HMI displays, compatible server-client versions list, and additional details please refer to KB117814 "AVEVA Midstream Product Bulletin - Removal of Binary Formatter" https://softwaresupportsp.aveva.com/en-US/knowledge/details/000117814?lang=en_US Mitigation AVEVA recommends the following general defensive measures: Audit devices, network topology, and perimeter defences to ensure all applicable security best practices from AVEVA's Enterprise SCADA Reference System Architecture are adhered to. Audit assigned permissions to ensure that only trusted users are given "DNA Authority - Operator" rights: https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html Disallow BLT Test clients in production environmentsFor additional details on defensive measures, refer to Section 5 of KB117814 "AVEVA Midstream Product Bulletin - Removal of Binary Formatter https://docs.aveva.com/bundle/scada-ent-2025/page/651008.html Mitigation For more information on this vulnerability, including security updates, users should see the security bulletin AVEVA-2026-005. https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-005.pdf Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H 4.0 6.1 MEDIUM CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments AVEVA reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks. Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Republication of AVEVA security bulletin AVEVA-2026-005 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Haiwell IoT Cloud HMI Gateway

View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-19188 A critical OS command injection vulnerability has been identified in the Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the Net Check feature accessible via the /setting endpoint. The cmdPing Socket.io event fails to properly sanitize user-supplied input before passing it to the underlying operating system, allowing an attacker to inject and execute arbitrary OS commands with root privileges View CVE Details Affected Products Haiwell IoT Cloud HMI Gateway Vendor: Haiwell Product Version: Haiwell Haiwell IoT Cloud HMI Gateway: 3.40.1.12 Product Status: known_affected Remediations Mitigation Haiwell has addressed the issue in patch version number Scada-v3.50.1.19, which is available for download on their website: https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361 https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Fiqram Akmal reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls Inc. Airwall

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of Hard-coded Cryptographic Key, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-64887 A hardcoded password or cryptographic key was identified in the Airwall application. A hardcoded credential leads to a significant authentication failure that can be difficult for system or application administrators to detect. Once discovered, it is difficult to remediate without manually modifying or patching the software. The hardcoded key is identical across all installations of the product and across all customer organizations, meaning a single disclosure of the key - common on the internet - grants any knowledgeable attacker access to all affected deployments. An attacker with access to application code or binary files can use the hardcoded key to decrypt sensitive application data stored in configuration and database files, enabling further data disclosure or compromise of application infrastructure. View CVE Details Affected Products Johnson Controls Inc. Airwall Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. Airwall: <=4.0.4 Product Status: known_affected Remediations Mitigation To help reduce risk of exploitation, Johnson Controls recommends the following defensive measures: Apply v4.1.0 or later patches for all Airwalls. Mitigation Store all cryptographic keys in a secure key management system (KMS) or hardware security module (HSM) rather than embedding them in source code or configuration files. (CVE-2026-64887) Mitigation Implement a regular key rotation policy to limit the exposure window if a key is compromised. (CVE-2026-64887) Mitigation Use unique cryptographic keys per device, installation, or deployment instance to prevent a single compromised key from affecting all installations. (CVE-2026-64887) Mitigation Remove any hard-coded keys from source code repositories and binaries, replacing them with references to secure external key stores. (CVE-2026-64887)Apply the principle of least privilege to key access, ensuring only authorized processes and personnel can retrieve cryptographic material. (CVE-2026-64887) Mitigation Use static analysis and secrets-scanning tools in CI/CD pipelines to detect and prevent hard-coded keys from being committed to source control. (CVE-2026-64887) Mitigation Encrypt keys at rest and in transit and ensure key-wrapping mechanisms are in place for any keys stored on disk. (CVE-2026-64887) Mitigation Audit and monitor access to cryptographic keys, logging all retrieval and usage events for anomaly detection. (CVE-2026-64887) Mitigation Refer to and follow all steps in the product hardening guide or the JCI universal hardening guide found here https://www.johnsoncontrols.com/trust-center/cybersecurity/resources (CVE-2026-64887) https://www.johnsoncontrols.com/trust-center/cybersecurity/resources Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-25 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories (CVE-2026-64887) https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-34492 An arbitrary file read vulnerability was identified in the Airwall application. This issue occurs when user-supplied input is directly incorporated into filesystem access functions without adequate validation or sanitization. As a result, an attacker can request and obtain the contents of arbitrary files on the server, including sensitive configuration files, source code, credential stores, and private keys, provided the application process has permission to read them. The vulnerability is commonly exploited through path traversal sequences (e.g., ../) or absolute file paths (e.g., /etc/passwd). Encoding variations of traversal sequences (e.g., %2e%2e%2f) can also bypass basic filters. View CVE Details Affected Products Johnson Controls Inc. Airwall Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. Airwall: <=4.0.4 Product Status: known_affected Remediations Mitigation To help reduce risk of exploitation, Johnson Controls recommends the following defensive measures: Apply v4.1.0 or later patches for all Airwalls. Mitigation Validate and sanitize all user-supplied input before using it in file system operations (CVE-2026-34492) Mitigation Implement strict allowlists for permitted file paths, file names, and directories (CVE-2026-34492) Mitigation Use canonicalization to resolve path traversal sequences before validation (CVE-2026-34492) Mitigation Apply the principle of least privilege to the application file system access permissions (CVE-2026-34492) Mitigation Deploy sandboxing or chroot jails to restrict the application's file system scope (CVE-2026-34492) Mitigation Avoid passing user-controlled data directly to file system APIs (CVE-2026-34492) Mitigation Refer to and follow all steps in the product hardening guide or the JCI universal hardening guide found here https://www.johnsoncontrols.com/trust-center/cybersecurity/resources (CVE-2026-34492) https://www.johnsoncontrols.com/trust-center/cybersecurity/resources Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-18 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories (CVE-2026-34492) https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L 4.0 5.9 MEDIUM CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Johnson Controls reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this (these) vulnerability(ies) has been reported to CISA at this time. This (these) vulnerability(ies) is (are) not exploitable remotely. This (these) vulnerability(ies) has (have) a high attack complexity. Revision History Initial Release Date: 2026-08-13 Date Revision Summary 2026-08-13 1 Initial Republication of Johnson Controls JCI-PSA-2026-18 and JCI-PSA-2026-25 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo…
Read full source summary
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC3 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC4 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E003 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E24 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC7 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) CVSS Vendor Equipment Vulnerabilities v3 4.3 Siemens Siemens Desigo DXR and PXC Controllers Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-59693 The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality. View CVE Details Affected Products Siemens Desigo DXR and PXC Controllers Vendor: Siemens Product Version: Desigo DXR2 < V01.21.233.16-7862, Desigo PXC3 < V01.21.233.16-7862, Desigo PXC4 < V02.21.194.36-2715, Desigo PXC5.E003 < V02.21.194.36-2715, Desigo PXC5.E24 < V02.21.194.36-2715, Desigo PXC7 < V02.21.194.36-2715 Product Status: known_affected Remediations Vendor fix Update to V01.21.233.16-7862 or later version Please contact your local Siemens office for additional support in obtaining the update. Vendor fix Update to V02.21.194.36-2715 or later version Please contact your local Siemens office for additional support in obtaining the update. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L Acknowledgments Thomas EBI of Sauter reported this vulnerability to Siemens General Recommendations As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-781903 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens SSA-781903 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens License Server (SLS)

View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1,…
Read full source summary
View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1, vers:intdot/<5.3 (CVE-2026-69108, CVE-2026-69109) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens License Server (SLS) Incorrect Permission Assignment for Critical Resource, Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-69108 The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise. View CVE Details Affected Products Siemens License Server (SLS) Vendor: Siemens Product Version: Siemens License Server (SLS) < V5.1 Product Status: known_affected Remediations Vendor fix Update to V5.1 or later version https://support.sw.siemens.com/product/1586485382/ Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N CVE-2026-69109 The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application. View CVE Details Affected Products Siemens License Server (SLS) Vendor: Siemens Product Version: Siemens License Server (SLS) < V5.3 Product Status: known_affected Remediations Vendor fix Update to V5.3 or later version https://support.sw.siemens.com/product/1586485382/ Relevant CWE: CWE-35 Path Traversal: '.../...//' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-077553 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens ProductCERT SSA-077553 advisory Legal Notice and Terms of Use