        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-05",
        "title": "Rockwell Automation 1756-ENBT Module",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover.</strong></p>\n<p>The following versions of Rockwell Automation 1756-ENBT Module are affected:</p>\n<ul>\n<li>1756-ENBT module vers:all/* (CVE-2025-10478)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation 1756-ENBT Module</td>\n<td>Improper Check for Unusual or Exceptional Conditions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Food and Agriculture, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-10478</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists in the Rockwell Automation 1756-ENBT module which is a ControlLogix EtherNet/IP bridge that enables communication between Logix 5000 controllers and Ethernet devices. An attacker could exploit this vulnerability by sending a crafted CIP packet, causing the module to crash. The device requires a restart to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-10478\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation 1756-ENBT Module</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation 1756-ENBT module: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation recommends that users upgrade to 1756-EN2T or 1756-EN4TR. Users who are not able to upgrade should use Rockwell Automation's security best practices.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information on this issue, see the corresponding Rockwell Automation security advisory.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/754.html\">CWE-754 Improper Check for Unusual or Exceptional Conditions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation security advisory.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-202-01",
        "title": "Tycon Systems TPDIN-Monitor-WEB2 (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-202-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-202-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk.</strong></p>\n<p>The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected:</p>\n<ul>\n<li>TPDIN-Monitor-WEB2 &lt;2.4.5 (CVE-2026-61884, CVE-2026-55985)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Tycon Systems</td>\n<td>Tycon Systems TPDIN-Monitor-WEB2</td>\n<td>Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-61884</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The device ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-61884\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Tycon Systems TPDIN-Monitor-WEB2 (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Tycon Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Tycon Systems TPDIN-Monitor-WEB2: &lt;2.4.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Tycon Systems has released firmware 2.4.5, which resolves this vulnerability by requiring an administrator username and password to be set before the web interface is served. Further inquiries can be directed to security@tyconsystems.com.</p>\n<p><strong>Mitigation</strong><br>Tycon Systems recommends setting an administrative username and strong password on the Network Configuration page and confirming in a private browser window that a login is required, for units still running firmware 2.4.4 or earlier. Repeat this after any factory reset.</p>\n<p><strong>Mitigation</strong><br>Tycon Systems recommends not exposing the web interface to the Internet, as it is HTTP only. The unit should be kept on a private network, behind a firewall or VPN.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-55985</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The device's web management interface stores and displays system credentials in cleartext on a certain configuration page accessible to authenticated users. Any party with access to the administrative dashboard can immediately read these credentials, which may be used to compromise other systems on the local network.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-55985\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Tycon Systems TPDIN-Monitor-WEB2 (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Tycon Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Tycon Systems TPDIN-Monitor-WEB2: &lt;2.4.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Tycon Systems has released firmware 2.4.5, which resolves this vulnerability by removing cleartext credentials from the web interface response. Further inquiries can be directed to security@tyconsystems.com.</p>\n<p><strong>Mitigation</strong><br>Tycon Systems recommends changing any factory-default SNMP community strings and the Telnet password if they were left at shipped values. Leave Telnet disabled unless required.</p>\n<p><strong>Mitigation</strong><br>Tycon Systems recommends using a dedicated mail account for device alerts, rather than an account also used for other sensitive purposes, to limit exposure if credentials are compromised.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abdiwelli Guled reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-21</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-21</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-09-03</td>\n<td>2</td>\n<td>Updated affected version range and vulnerability details based on vendor input.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-06",
        "title": "Inductive Automation Ignition",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow any authenticated user to create projects.</strong></p>\n<p>The following versions of Inductive Automation Ignition are affected:</p>\n<ul>\n<li>Ignition &lt;=8.1.53 (CVE-2026-77393)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Inductive Automation</td>\n<td>Inductive Automation Ignition</td>\n<td>Incorrect Default Permissions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77393</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>In Ignition 8.1.53 and earlier, the Gateway \"Create Project Role(s)\" setting shipped blank, which permitted any authenticated user to create projects (if they can execute gateway scripts). Ignition 8.1.54 restricts project creation to Designer sessions and no longer relies on this setting. The 8.3 series is not affected.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77393\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Inductive Automation Ignition</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Inductive Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Inductive Automation Ignition: &lt;=8.1.53</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Inductive Automation has determined that this issue is a default-value configuration, not a flaw in the access control itself. The security control enforces exactly what the \"Create Project Role(s)\" setting specifies; because the setting shipped blank, no role was required to create a project. Populating the setting fully closes the vulnerability.</p>\n<p><strong>Mitigation</strong><br>Inductive Automation recommends users upgrade to 8.1.54 or later (or the latest 8.3 version), which restricts project creation to Designer sessions and no longer relies on this setting. Users who must remain on an earlier 8.1 version can fully remediate the issue by setting \"Create Project Role(s)\" to match their Designer Role. Once the setting is populated, only users holding that role can create projects. See Gateway General Security Settings.<br><a href=\"https://docs.inductiveautomation.com/docs/8.1/platform/security/gateway-general-security-settings#gateway-security-settings-table\">https://docs.inductiveautomation.com/docs/8.1/platform/security/gateway-general-security-settings#gateway-security-settings-table</a></p>\n<p><strong>Mitigation</strong><br>For more information, see the publication at the Inductive Automation Trust Center.<br><a href=\"https://security.inductiveautomation.com/?tcuUid=34477620-731d-4b70-b22b-9450f9a659a3\">https://security.inductiveautomation.com/?tcuUid=34477620-731d-4b70-b22b-9450f9a659a3</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Christopher Lusk of North Echo Security Research reported this vulnerability to Inductive Automation.</li>\n<li>Elhussain Fathy (0xSphinx) independently reported this vulnerability and confirmed the fix.</li>\n<li>Inductive Automation reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Republication of Inductive Automation Trust Center update.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-01",
        "title": "OPCFoundation OPC UA LocalDiscoveryServer (LDS)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands.</strong></p>\n<p>The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected:</p>\n<ul>\n<li>UA-LDS-Installers &lt;1.04.420 (CVE-2026-77477)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 4.6</td>\n<td>OPCFoundation</td>\n<td>OPCFoundation OPC UA LocalDiscoveryServer (LDS)</td>\n<td>Execution with Unnecessary Privileges</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Energy, Food and Agriculture, Water and Wastewater, Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77477</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker can intercept a high-privilege console window launched during installation of the LDS. The attacker must be able to launch an installer with elevated privileges and have access to the keyboard and display while the installation is taking place.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77477\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>OPCFoundation OPC UA LocalDiscoveryServer (LDS)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>OPCFoundation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>OPCFoundation UA-LDS-Installers: &lt;1.04.420</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>OPCFoundation recommends users update to OPC UA LDS Installers 1.04.420 or later.</p>\n<p><strong>Mitigation</strong><br>For more information about this vulnerability and its mitigation, see the OPCFoundation security advisory.<br><a href=\"https://github.com/OPCFoundation/OPC-SecurityAdvisories/tree/latest/csaf/2026/009\">https://github.com/OPCFoundation/OPC-SecurityAdvisories/tree/latest/csaf/2026/009</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/250.html\">CWE-250 Execution with Unnecessary Privileges</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>2.4</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Lukas Schumaker of Rockwell Automation reported this vulnerability to OPCFoundation.</li>\n<li>OPCFoundation reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-08",
        "title": "Tycon Systems TPDIN-Monitor-WEB3",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information.</strong></p>\n<p>The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected:</p>\n<ul>\n<li>TPDIN-Monitor-WEB3 &lt;=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Tycon Systems</td>\n<td>Tycon Systems TPDIN-Monitor-WEB3</td>\n<td>Use of Hard-coded Credentials, Cross-Site Request Forgery (CSRF), Missing Authorization</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77847</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a Use of Hard-coded Credential vulnerability. This could allow an attacker to intercept sensitive information or credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77847\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Tycon Systems TPDIN-Monitor-WEB3</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Tycon Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Tycon Systems TPDIN-Monitor-WEB3: &lt;=2.2.9</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Tycon Systems has released TPDIN-Monitor-WEB3 Firmware v2.4.2.</p>\n<p><strong>Mitigation</strong><br>Units already running v2.4.2, for subsequent updates (signed container):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw</a></p>\n<p><strong>Mitigation</strong><br>All units currently in the field, including the v2.2.9 covered by this report (legacy Intel HEX):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex</a></p>\n<p><strong>Mitigation</strong><br>A unit running v2.2.9 installs the .hex build directly and arrives at v2.4.2 in a single step; no intermediate version is required. The signed .tfw container cannot be read by a v2.2.9 updater, which accepts only Intel HEX, so the .hex artifact is the one every deployed unit needs.</p>\n<p><strong>Mitigation</strong><br>For more information, contact Tycon Systems:&nbsp;<br><a href=\"https://www.tyconsystems.com/contact\">https://www.tyconsystems.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-82712</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a Cross-Site Request Forgery vulnerability. This could allow an attacker to perform state changing operations on the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82712\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Tycon Systems TPDIN-Monitor-WEB3</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Tycon Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Tycon Systems TPDIN-Monitor-WEB3: &lt;=2.2.9</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Tycon Systems has released TPDIN-Monitor-WEB3 Firmware v2.4.2.</p>\n<p><strong>Mitigation</strong><br>Units already running v2.4.2, for subsequent updates (signed container):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw</a></p>\n<p><strong>Mitigation</strong><br>All units currently in the field, including the v2.2.9 covered by this report (legacy Intel HEX):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex</a></p>\n<p><strong>Mitigation</strong><br>A unit running v2.2.9 installs the .hex build directly and arrives at v2.4.2 in a single step; no intermediate version is required. The signed .tfw container cannot be read by a v2.2.9 updater, which accepts only Intel HEX, so the .hex artifact is the one every deployed unit needs.</p>\n<p><strong>Mitigation</strong><br>For more information, contact Tycon Systems:&nbsp;<br><a href=\"https://www.tyconsystems.com/contact\">https://www.tyconsystems.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/352.html\">CWE-352 Cross-Site Request Forgery (CSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-82684</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a Missing Authorization vulnerability. This could allow an attacker to extract system credentials, configurations, or flash contents.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82684\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Tycon Systems TPDIN-Monitor-WEB3</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Tycon Systems</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Tycon Systems TPDIN-Monitor-WEB3: &lt;=2.2.9</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Tycon Systems has released TPDIN-Monitor-WEB3 Firmware v2.4.2.</p>\n<p><strong>Mitigation</strong><br>Units already running v2.4.2, for subsequent updates (signed container):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2.tfw</a></p>\n<p><strong>Mitigation</strong><br>All units currently in the field, including the v2.2.9 covered by this report (legacy Intel HEX):&nbsp;<br><a href=\"https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex\">https://firm.tyconsystems.com/tpdin-monitor-web3-v2/TPDIN-MONITOR-WEB3-V2_v2.4.2T.hex</a></p>\n<p><strong>Mitigation</strong><br>A unit running v2.2.9 installs the .hex build directly and arrives at v2.4.2 in a single step; no intermediate version is required. The signed .tfw container cannot be read by a v2.2.9 updater, which accepts only Intel HEX, so the .hex artifact is the one every deployed unit needs.</p>\n<p><strong>Mitigation</strong><br>For more information, contact Tycon Systems:&nbsp;<br><a href=\"https://www.tyconsystems.com/contact\">https://www.tyconsystems.com/contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abdiwelli Guled reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-07",
        "title": "Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-169-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-169-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. The Easergy MiCOM C264 is a modular and compact substation or bay controller, smart RTU and MV one box solution The EcoStruxure Power Automation System Gateway (EPAS=GTW) is a scalable, interoperable, and rugged communication gateway that helps to remotely monitor and operate electrical processes The EcoStruxure Power Automation System User Interface (EPAS-UI) product is an HMI SCADA designed for electrical networks and substations operations. The EcoStruxure Power Automation System Intelligent Power Management System and Fast Load Shedding (iPMFLS) is a range of solutions designed to overcome size and performances constraints. The EcoStruxure Power Operation (EPO) are an on-premises software offers that provides a single platform to monitor and control medium and lower power systems. The PowerLogic P5 is a medium voltage protection relay. The PowerLogic P7 is a protection and control platform designed for complex and advanced electrical network applications. The PowerLogic T300 is a modular platform for medium voltage and low voltage public distribution network management. The PowerLogic T500 is a control unit and RTU for substation automation. The Saitel DP RTU is a modular platform for medium voltage and low voltage public distribution and transmission network management. The EasyLogic T150 (formerly Saitel DR RTU) is a field device, offering a solid and powerful platform for data acquisition, communication, automation and IED integration for distribution and transmission networks, generation sector and railway. Failure to apply the fix provided below may risk session hijacking, which could result in malicious actors performing unauthorized operations within the affected system.</strong></p>\n<p>The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A) are affected:</p>\n<ul>\n<li>Easergy MiCOM C264 vers:generic/&lt;=D7.33 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P139 vers:generic/&lt;=P139.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P437 vers:generic/&lt;=P437.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P439 vers:generic/&lt;=P439.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P532 vers:generic/&lt;=P532.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P539 vers:generic/&lt;=P539.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P631 vers:generic/&lt;=P631.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P632 vers:generic/&lt;=P632.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P633 vers:generic/&lt;=P633.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P634 vers:generic/&lt;=P634.678.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P633 P633.680.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P634 P634.680.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P138 vers:generic/&lt;=P138.677.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P436 vers:generic/&lt;=P436.677.701 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P438 vers:generic/&lt;=P438.677.701 (CVE-2026-4827)</li>\n<li>Easergy MiCOM P638 vers:generic/&lt;=P638.677.700 (CVE-2026-4827)</li>\n<li>Easergy MiCOM C434 vers:generic/&lt;=C434.679.700 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Automation System Gateway (EPAS-GTW) vers:intdot/&lt;=6.4.616.200.100 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Automation System User Interface (EPAS-UI) vers:intdot/&lt;=3.0.3 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Operation vers:generic/&lt;=2022_CU6 (CVE-2026-4827)</li>\n<li>EcoStruxure Power Operation vers:generic/&lt;=2024_CU2 (CVE-2026-4827)</li>\n<li>iPMFLS vers:intdot/&lt;=64.2025.0.13 (CVE-2026-4827)</li>\n<li>PowerLogic P5 Protection Relay vers:intdot/&lt;=02.502.103 (CVE-2026-4827)</li>\n<li>PowerLogic P7 Protection and Control Platform vers:intdot/&lt;=02.002.002 (CVE-2026-4827)</li>\n<li>PowerLogic T300 vers:intdot/&lt;=2.9.4 (CVE-2026-4827)</li>\n<li>PowerLogic T500 vers:intdot/&lt;=11.08.02 (CVE-2026-4827)</li>\n<li>Saitel DP vers:intdot/&lt;=11.06.36 ()</li>\n<li>EasyLogic T150 (formerly Saitel DR) vers:intdot/&lt;=11.06.30 ()</li>\n<li>Easergy MiCOM C264 D7.34 ()</li>\n<li>Easergy C5 vers:intdot/&lt;=1.1.17 (CVE-2026-4827)</li>\n<li>Easergy C5 1.1.18 ()</li>\n<li>Easergy MiCOM P139 version P139.678.700 ()</li>\n<li>Easergy MiCOM P439 P439.678.700 ()</li>\n<li>Easergy MiCOM P539 P539.678.700 ()</li>\n<li>Easergy MiCOM P632 P632.678.700 ()</li>\n<li>Easergy MiCOM P633 P633.680.701 ()</li>\n<li>Easergy MiCOM P634 P634.680.701 ()</li>\n<li>Easergy MiCOM P633 P633.678.700 ()</li>\n<li>Easergy MiCOM P138 P138.677.701 ()</li>\n<li>Easergy MiCOM C434 C434.679.700 ()</li>\n<li>Saitel DR 11.06.31 ()</li>\n<li>EcoStruxure Power Automation System Gateway (EPAS-GTW) 6.4.610.500.101 ()</li>\n<li>EcoStruxure Power Automation Automation System User Interface (EPAS-UI) 3.0.4 ()</li>\n<li>EcoStruxure Power Operation 2022_CU7 ()</li>\n<li>EcoStruxure Power Operation (EPO) 2024_CU3 ()</li>\n<li>iPMFLS 64.2025.0.14 ()</li>\n<li>PowerLogic P5 Protection Relay 02.503.101 ()</li>\n<li>PowerLogic P7 Protection and Control Platform 02.003.001 ()</li>\n<li>PowerLogic T300 2.9.5 ()</li>\n<li>PowerLogic T500 11.08.03 ()</li>\n<li>Saitel DP 11.06.37 ()</li>\n<li>Easergy MiCOM P40 Series vers:all/* (CVE-2026-4827)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products</td>\n<td>Insufficient Entropy</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-4827</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-331 Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session\u2011management protections.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-4827\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Easergy MiCOM C264 Versions D7.33 and prior, Easergy MiCOM P139 version prior to P139.678.700, Easergy MiCOM P437 version prior to P437.678.700, Easergy MiCOM P439 version prior to P439.678.700, Easergy MiCOM P532 version prior to P532.678.700, Easergy MiCOM P539 version prior to P539.678.700, Easergy MiCOM P631 version prior to P631.678.700, Easergy MiCOM P632 version prior to P632.678.700, Easergy MiCOM P633 version prior to P633.678.700, Easergy MiCOM P634 version prior to P634.678.700, Easergy MiCOM P633 version P633.680.700, Easergy MiCOM P634 version P634.680.700 , Easergy MiCOM P138 version prior to P138.677.700, Easergy MiCOM P436 version prior to P436.677.701, Easergy MiCOM P438 version prior to P438.677.701, Easergy MiCOM P638 version prior to P638.677.700, Easergy MiCOM C434 version prior to C434.679.700, EcoStruxure Power Automation System Gateway (EPAS-GTW) Version 6.4.616.200.100 and prior, EcoStruxure Power Automation System User Interface (EPAS-UI) Version 3.0.3 and prior, EcoStruxure Power Operation (EPO) 2022 CU6 and prior, EcoStruxure Power Operation (EPO) 2024 CU2 and prior, iPMFLS Version 64.2025.0.13 and prior, PowerLogic P5 Protection Relay V02.502.103 and prior, PowerLogic P7 Protection and Control Platform V02.002.002 and prior, PowerLogic T300 Version 2.9.4 and prior, PowerLogic T500 Version 11.08.02 and prior, Easergy C5 Version 1.1.17 and prior, Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L and all firmware versions</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required.</p>\n<p><strong>Vendor fix</strong><br>Version 1.1.18 of Easergy C5 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required.</p>\n<p><strong>Vendor fix</strong><br>Version P139.678.700 Easergy MiCOM P139 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P439.678.700 Easergy MiCOM P439 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P539.678.700 Easergy MiCOM P539 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P632.678.700 Easergy MiCOM P632 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P633.678.700 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P634.680.701 Easergy MiCOM P634 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P633.680.701 Easergy MiCOM P633 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version P138.677.701 Easergy MiCOM P138 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version C434.679.700 Easergy MiCOM C434 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>HUe Firmware version 11.06.31 includes a fix for this vulnerability and is available for download here: . Contact Schneider Electric\u2019s Customer Care Center to download this software. A reboot is needed to complete the firmware upgrade.</p>\n<p><strong>Vendor fix</strong><br>Version 6.4.610.500.101 of EPAS Gateway includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this software.</p>\n<p><strong>Vendor fix</strong><br>Version 3.0.4 of EPAS-UI includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this software.</p>\n<p><strong>Vendor fix</strong><br>EPO 2022 CU 7 of EcoStruxure Power Operation includes a fix for this vulnerability and is available for download here:&nbsp;<br><a href=\"https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787\">https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2022-CU7-is-Now-Available/td-p/524787</a></p>\n<p>Reboot needed: yes</p>\n<p><strong>Vendor fix</strong><br>EPO 2024 CU 3 of EcoStruxure Power Operation includes a fix for this vulnerability and is available for download here:&nbsp;<br><a href=\"https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769\">https://community.se.com/t5/EcoStruxure-Power-Operation/Power-Operation-2024-CU3-is-HERE/td-p/534769</a></p>\n<p>Reboot needed: yes</p>\n<p><strong>Vendor fix</strong><br>Version 64.2025.0.14 of iPMFLS includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center for information on how to contact your local Application Center to update the device.</p>\n<p><strong>Vendor fix</strong><br>Version V02.503.101 of PowerLogic P5 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this firmware.</p>\n<p><strong>Vendor fix</strong><br>Version V02.003.001 of PowerLogic P7 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this firmware.</p>\n<p><strong>Vendor fix</strong><br>Version 2.9.5 of PowerLogic T300 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade.</p>\n<p><strong>Vendor fix</strong><br>Version 11.08.03 of PowerLogic T500 includes a fix for this vulnerability. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade.</p>\n<p><strong>Vendor fix</strong><br>CPU866e Firmware version 11.06.37 includes a fix for this vulnerability and is available for download. Contact Schneider Electric\u2019s Customer Care Center to download this firmware. A reboot is needed to complete the firmware upgrade.</p>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for all future versions of the following models of the Easergy MiCOM P30: P437 P532 P631 P634 P436 P438 P638 Future versions will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:&nbsp;</p>\n<ul>\n<li>Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures.&nbsp;</li>\n<li>Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions.</li>\n</ul>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for a future version of the Easergy MiCOM P40 Series model numbers with Protocol Option bit as G, H or L. P_ 4_ _ _ _ _ G_ _ _ _ _ M P_ 4_ _ _ _ _ H_ _ _ _ _ M P_ 4_ _ _ _ _ L _ _ _ _ _ M P_ 4_ _ _ _ _ G_ _ _ _ _ L P_ 4_ _ _ _ _ H_ _ _ _ _ L P_ 4_ _ _ _ _ L _ _ _ _ _ L A future version will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:&nbsp;</p>\n<ul>\n<li>Ensure P40 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures.&nbsp;</li>\n<li>Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions.</li>\n</ul>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:</p>\n<ul>\n<li>Ensure P30 operates within a physically or logically segmented internal network. Access to this network should be tightly controlled using standard security mechanisms such as firewalls, intrusion detection systems (IDS), and other relevant protective measures.&nbsp;</li>\n<li>Reduce the \u201cMinimum inactivity period\u201d using the CAE tool to shorten session timeout durations and minimize the risk of unauthorized access due to inactive sessions.</li>\n</ul>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/331.html\">CWE-331 Insufficient Entropy</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An internal researcher of Schneider Electric reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-05-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-05-12</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-06-18</td>\n<td>2</td>\n<td>Initial Republication of Schneider Electric CPCERT SEVD-2026-132-02</td>\n</tr>\n<tr>\n<td>2026-09-03</td>\n<td>3</td>\n<td>Update A - Revised the summary to reflect the affected products</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-03",
        "title": "Rockwell Automation ControlFLASH",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level.</strong></p>\n<p>The following versions of Rockwell Automation ControlFLASH are affected:</p>\n<ul>\n<li>ControlFLASH &lt;=V15.07 (CVE-2026-12663)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.3</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation ControlFLASH</td>\n<td>Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12663</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within ControlFLASH, where the installer grants write permissions to the \"Everyone\" group on a product installation directory. This could allow arbitrary code execution, resulting in an attacker being given the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12663\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ControlFLASH</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ControlFLASH: &lt;=V15.07</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation has corrected this issue in software version 15.08, and encourages all users to update to the newest version.</p>\n<p><strong>Mitigation</strong><br>Users of the affected software who are not able to upgrade to one of the corrected versions should implement the following mitigation:&nbsp;</p>\n<p>To protect the files, do the following steps to remove the Everyone group:&nbsp;</p>\n<ol>\n<li>Right-click the C:\\Program Files (x86)\\ControlFLASH\\0001 folder, and then select Properties.&nbsp;</li>\n<li>In the 0001 Properties dialog, select the Security tab, and then select Edit.&nbsp;</li>\n<li>In the Permissions for 0001 dialog, in Group or user names, select Everyone, and then select Remove.&nbsp;</li>\n<li>Select OK.</li>\n</ol>\n<p><strong>Mitigation</strong><br>If the mitigation above cannot be implemented, Rockwell Automation recommends following their security best practices.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information on this issue, see the Rockwell Automation security advisory at: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation security advisory.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-04",
        "title": "Rockwell Automation ArmorStart LT",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page.</strong></p>\n<p>The following versions of Rockwell Automation ArmorStart LT are affected:</p>\n<ul>\n<li>ArmorStart LT &lt;=v2.001 (CVE-2026-19471, CVE-2026-19472)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation ArmorStart LT</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Allocation of Resources Without Limits or Throttling</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-19471</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Multiple stored cross-site scripting security issues exist within ArmorStart LT. Stored XSS occurs when user input is not properly sanitized and is stored on the server, allowing an attacker to inject malicious scripts that will be executed when other users access the affected page.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-19471\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT: &lt;=v2.001</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation has corrected this issue in firmware version v2.002, and encourages all users to update to the newest version.</p>\n<p><strong>Mitigation</strong><br>Users of the affected software who are not able to upgrade to one of the corrected versions should follow Rockwell Automation's security best practices.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information on this issue, see the Rockwell Automation security advisory at: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-19472</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within ArmorStart LT. The security issue stems from improper handling of a crafted HTTP PUT request sent to the embedded web server. This can result in a loss of web server availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-19472\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ArmorStart LT</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ArmorStart LT: &lt;=v2.001</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation has corrected this issue in firmware version v2.002, and encourages all users to update to the newest version.</p>\n<p><strong>Mitigation</strong><br>Users of the affected software who are not able to upgrade to one of the corrected versions should follow Rockwell Automation's security best practices.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information on this issue, see the Rockwell Automation security advisory at: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation security advisory.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-02",
        "title": "IXON VPN Client",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges.</strong></p>\n<p>The following versions of IXON VPN Client are affected:</p>\n<ul>\n<li>VPN Client &lt;1.4.7 (CVE-2026-75925)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.6</td>\n<td>IXON</td>\n<td>IXON VPN Client</td>\n<td>Improper Neutralization of CRLF Sequences ('CRLF Injection')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Netherlands</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-75925</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Neutralization of CRLF Sequences (CWE-93) in IXON VPN Client before version 1.4.7 allows an attacker to execute commands as root or SYSTEM. Configuration values accepted by the local service are written to a file later consumed by a privileged subprocess, without line-ending sequences being neutralised, which allows additional directives to be introduced into that file. The configuration interface accepts changes without authenticating or verifying the origin of the requester (CWE-306, contributing). The injected configuration persists on disk across restarts of the client and the operating system, and the VPN connection continues to function normally, so there is no behavioral change visible to the user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-75925\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>IXON VPN Client</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>IXON</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>IXON VPN Client: &lt;1.4.7</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>IXON recommends updating the IXON VPN client to version 1.4.7 or later on every computer where it is installed.</p>\n<p><strong>Mitigation</strong><br>As of August 5, 2026, IXON cloud rejects connections from clients below v1.4.7 at both the portal and the back-end API. Since the privileged subprocess and injected listener are only created when the client connects, unpatched installations cannot complete the exploit chain.</p>\n<p><strong>Mitigation</strong><br>If the client is no longer needed, IXON recommends uninstalling the VPN client from the computer.</p>\n<p><strong>Mitigation</strong><br>For more information please refer to the IXON Trust Center Advisory at https://www.ixon.cloud/Advisories/ADV-2026-08-05.pdf.<br><a href=\"https://www.ixon.cloud/Advisories/ADV-2026-08-05.pdf%60\">https://www.ixon.cloud/Advisories/ADV-2026-08-05.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/93.html\">CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.6</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Luuk van Rheden of IXON discovered this vulnerability.</li>\n<li>Stan van Duijnhoven of IXON reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-05</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-05</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-09-03</td>\n<td>2</td>\n<td>Initial Republication by CISA</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/preparing-post-quantum-era-call-action",
        "title": "Preparing for the Post-Quantum Era: A Call to Action",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/preparing-post-quantum-era-call-action",
        "summary": "<p>CISA and the Group of Seven (G7) Cyber Security Working Group released <a href=\"https://urldefense.us/v3/__https:/cyber.gouv.fr/en/publications/jointly-led-international-publications/preparing-for-the-post-quantum-era-a-call-to-action/__;!!BClRuOV5cvtbuNI!A4T2ayZfcpa7J25BSkxtB9A-AHREvqT8FQmzhRjVarx8w3J-Vs-CBcKQcElRqsqsZqtIztYiIMY01My3HFmonToxreu7Z35ka6L8naw5xg$\" target=\"_blank\"><em>Preparing for the Post-Quantum Era: A Call to Action</em></a><em> </em>highlighting the urgent need for organizations and governments to begin transitioning to post-quantum cryptography (PQC) to protect sensitive data, authentication systems, and critical assets from emerging quantum computing threats. &nbsp;</p>\n<p>The G7 Cyber Security Working Group\u2019s call to action outlines five priorities for a successful transition to PQC:</p>\n<ul>\n<li>Raising awareness of quantum risks and the importance of PQC;</li>\n<li>Developing national strategies that support PQC adoption and integration;</li>\n<li>Advancing research and development for quantum-safe technologies;</li>\n<li>Fostering public-private partnerships to share expertise and resources; and</li>\n<li>Integrating PQC into cybersecurity requirements and procurement processes.&nbsp;</li>\n</ul>\n<div class=\"c-text-cta\">\n<div class=\"l-constrain c-text-cta__inner\">\n<div class=\"c-text-cta__content\">\n<h2>Please share your thoughts!</h2>\n<div class=\"c-text-cta__summary\">\n<p>We welcome your feedback.</p>\n</div>\n<p><a class=\"c-button c-button--on-dark\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/resources-tools/resources/preparing-post-quantum-era-call-action\">CISA PRODUCT SURVEY</a></p>\n</div>\n</div>\n</div>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-07",
        "title": "Pyramid Solutions NetStaX EtherNet/IP Stack",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-246-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed.</strong></p>\n<p>The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected:</p>\n<ul>\n<li>EtherNet/IP Adapter DLL Kit (EIPA)</li>\n<li>EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE)</li>\n<li>EtherNet/IP Adapter Development Kit (EADK)</li>\n<li>EtherNet/IP Adapter Development Kit with CIP Security (EADK-SECURE)</li>\n<li>EtherNet/IP Scanner DLL Kit (EIPS)</li>\n<li>EtherNet/IP Scanner DLL Kit with CIP Security (EIPS-SECURE)</li>\n<li>EtherNet/IP Scanner Development Kit (ESDK)</li>\n<li>EtherNet/IP Scanner Development Kit with CIP Security (ESDK-SECURE)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Pyramid Solutions</td>\n<td>Pyramid Solutions NetStaX EtherNet/IP Stack</td>\n<td>Stack-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Water and Wastewater, Chemical</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-78012</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An issue in the NetStaX EtherNet/IP Stack prior to v5.6.1 could allow a large Class 3 explicit-message request to exceed the application-side receive buffer without generating an error or warning. The result could be memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-78012\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Pyramid Solutions NetStaX EtherNet/IP Stack</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Pyramid Solutions</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Pyramid Solutions EtherNet/IP Adapter DLL Kit (EIPA): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Adapter Development Kit (EADK): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Adapter Development Kit with CIP Security (EADK-SECURE): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Scanner DLL Kit (EIPS): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Scanner DLL Kit with CIP Security (EIPS-SECURE): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Scanner Development Kit (ESDK): &lt;v5.6.1, Pyramid Solutions EtherNet/IP Scanner Development Kit with CIP Security (ESDK-SECURE): &lt;v5.6.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>NetStaX v5.6.1 addresses this issue with multiple layers of protection, including a compile-time assertion, a runtime payload-size check, and clearer documentation of the relationships between packet and buffer-size constants.<br><a href=\"https://pyramidsolutions.com/my-account/\">https://pyramidsolutions.com/my-account/</a></p>\n<p><strong>Mitigation</strong><br>For more information, see the Pyramid Solutions blog post \"NetStaX v5.6.1: Protecting Against Silent Buffer Overflow in Ethernet/IP Stack Explicit Messages\".<br><a href=\"https://pyramidsolutions.com/netstax-v-5-6-1-protecting-against-silent-buffer-overflow-in-ethernet-ip-stack-explicit-messages/\">https://pyramidsolutions.com/netstax-v-5-6-1-protecting-against-silent-buffer-overflow-in-ethernet-ip-stack-explicit-messages/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Pyramid Solutions reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Initial Republication of Pyramid Solutions blog publication.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 03 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 03 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/02/cisa-adds-seven-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Seven Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/02/cisa-adds-seven-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added seven new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation. &nbsp;</p>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9586\" target=\"_blank\"><u>CVE-2026-9586</u></a> Sangoma Switchvox SQL Injection Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-48710\" target=\"_blank\"><u>CVE-2026-48710</u></a> Kludex Starlette HTTP Request/Response Smuggling Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-49869\" target=\"_blank\"><u>CVE-2026-49869</u></a> Kestra OSS OS Command Injection Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-59822\" target=\"_blank\"><u>CVE-2026-59822</u></a> BerriAI LiteLLM Improper Authentication Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82329\" target=\"_blank\"><u>CVE-2026-82329</u></a> JFrog Artifactory Improper Authentication Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-83548\" target=\"_blank\"><u>CVE-2026-83548</u></a> SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW190820602 BCX8\">\n<ul type=\"disc\">\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-83549\" target=\"_blank\"><u>CVE-2026-83549</u></a> SonicWall SMA1000 Appliances OS Command Injection Vulnerability&nbsp;</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\"><u>Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</u></a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" target=\"_blank\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a class=\"ext\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\"><u>KEV Nomination Form</u></a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Wed, 02 Sep 26 12:00:00 +0000",
        "last_updated": "Wed, 02 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/communicating-under-pressure-best-practices-service-providers",
        "title": "Communicating Under Pressure: Best Practices for Service Providers",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/communicating-under-pressure-best-practices-service-providers",
        "summary": "<p>Developed by CISA, the Federal Bureau of Investigation, and international partners, this <a href=\"https://www.cisa.gov/sites/default/files/2026-09/joint-guidance-communicating-under-pressure-508c.pdf\" title=\"Communicating Under Pressure: Best Practices for Service Providers\">guidance</a> describes how organizations can plan and execute clear, timely, accurate, and audience-appropriate communications during IT and operational technology (OT) outages. Whether caused by cyber threat actors, human error, equipment failure, or natural hazards, service outages can create disruption and societal panic even without speculation from end users and the public as added factors. Outages at one organization may cascade across interconnected systems, increasing uncertainty and alarm. The guidance emphasizes clarity, accountability, and transparency as core principles and details key elements of effective crisis messaging to inform affected stakeholders and the public while aligning with legal requirements, operational security, law enforcement, and containment efforts.&nbsp;</p>\n<p>CISA\u2019s <a href=\"https://www.cisa.gov/topics/industrial-control-systems/ci-fortify\">CI Fortify</a> initiative provides information and resources that help critical infrastructure organizations prepare to isolate and recover vital OT systems during a major cyber incident or crisis. Changes in service availability, whether from outages or isolation as a defensive strategy, require transparent and ongoing communication to help end users minimize operational impact, limit speculation, and preserve trust. For emergency planning purposes, critical infrastructure owners and operators should assume that telecommunications services may be disrupted or otherwise unreliable, making it crucial for organizations to have crisis communications plans in place that integrate backup communication methods and understand the type of communication they should expect from their service providers.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 02 Sep 26 12:00:00 +0000",
        "last_updated": "Wed, 02 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-06",
        "title": "Rockwell Automation Historian ME",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution.</strong></p>\n<p>The following versions of Rockwell Automation Historian ME are affected:</p>\n<ul>\n<li>Series B 5.202 (CVE-2025-12768, CVE-2026-12661)</li>\n<li>Series C 7.101 (CVE-2025-12768, CVE-2026-12661)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation Historian ME</td>\n<td>Out-of-bounds Write, Stack-based Buffer Overflow</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Food and Agriculture, Healthcare and Public Health, Water and Wastewater Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-12768</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within FactoryTalk\u00ae Historian Machine Edition. An attacker with low-level authentication could exploit this vulnerability to achieveremote code execution on the affected device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-12768\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Historian ME</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Series B: 5.202, Rockwell Automation Series C: 7.101</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automations security best practices found at https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding the security issue(s) above and how to mitigate them, contact TechConnect for help. More information can be found at https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html.<br><a href=\"https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html\">https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding this disclosure, please contact PSIRT Email: rasecure@ra.rockwell.com<br><a href=\"mailto:rasecure@ra.rockwell.com\">mailto:rasecure@ra.rockwell.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-12661</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within FactoryTalk\u00ae Historian Machine Edition. A network adjacent attacker who is authenticated could send craftedrequests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-12661\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Historian ME</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Series B: 5.202, Rockwell Automation Series C: 7.101</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automations security best practices found at https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding the security issue(s) above and how to mitigate them, contact TechConnect for help. More information can be found at https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html.<br><a href=\"https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html\">https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding this disclosure, please contact PSIRT Email: rasecure@ra.rockwell.com<br><a href=\"mailto:rasecure@ra.rockwell.com\">mailto:rasecure@ra.rockwell.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/121.html\">CWE-121 Stack-based Buffer Overflow</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>4.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-04",
        "title": "Rockwell Automation FactoryTalk Activation Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p>The following versions of Rockwell Automation FactoryTalk Activation Manager are affected:</p>\n<ul>\n<li>FactoryTalk Activation Manager V5.02_and_below (CVE-2026-16675)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation FactoryTalk Activation Manager</td>\n<td>Improper Restriction of Excessive Authentication Attempts</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-16675</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A privilege escalation vulnerability exists within FactoryTalk Activation Manager. The vulnerability stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-16675\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation FactoryTalk Activation Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation FactoryTalk Activation Manager V5.02_and_below</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to software version V5.03.</p>\n<p><strong>Mitigation</strong><br>Customers using the affected software who are not able to upgrade to one of the corrected versions should use Rockwell Automation's security best practices.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>An anonymous security researcher reported this vulnerability to Rockwell Automation, who reported it to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial republication of Rockwell Automation advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-05",
        "title": "Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p>The following versions of Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix are affected:</p>\n<ul>\n<li>ControlLogix 5580 &lt;34.015, &lt;35.014, &lt;36.013, &lt;37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)</li>\n<li>GuardLogix 5580 &lt;34.015, &lt;35.014, &lt;36.013, &lt;37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)</li>\n<li>CompactLogix 5380 &lt;34.015, &lt;35.014, &lt;36.013, &lt;37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)</li>\n<li>Compact GuardLogix 5380 &lt;34.015, &lt;35.014, &lt;36.013, &lt;37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)</li>\n<li>CompactLogix 5480 &lt;34.015, &lt;35.014, &lt;36.013, &lt;37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix</td>\n<td>Loop with Unreachable Exit Condition ('Infinite Loop')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2021-42260</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A potential denial of service vulnerability exists in the affected products and can be triggered via corrupt crafted data. This could result in a major nonrecoverable fault (MNRF). A program download is required to recover safety controllers. For non-safety controllers, a stage 2 reset is required to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-42260\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ControlLogix 5580 &lt;34.015, Rockwell Automation ControlLogix 5580 &lt;35.014, Rockwell Automation ControlLogix 5580 &lt;36.013, Rockwell Automation ControlLogix 5580 &lt;37.011, Rockwell Automation GuardLogix 5580 &lt;34.015, Rockwell Automation GuardLogix 5580 &lt;35.014, Rockwell Automation GuardLogix 5580 &lt;36.013, Rockwell Automation GuardLogix 5580 &lt;37.011, Rockwell Automation CompactLogix 5380 &lt;34.015, Rockwell Automation CompactLogix 5380 &lt;35.014, Rockwell Automation CompactLogix 5380 &lt;36.013, Rockwell Automation CompactLogix 5380 &lt;37.011, Rockwell Automation Compact GuardLogix 5380 &lt;34.015, Rockwell Automation Compact GuardLogix 5380 &lt;35.014, Rockwell Automation Compact GuardLogix 5380 &lt;36.013, Rockwell Automation Compact GuardLogix 5380 &lt;37.011, Rockwell Automation CompactLogix 5480 &lt;34.015, Rockwell Automation CompactLogix 5480 &lt;35.014, Rockwell Automation CompactLogix 5480 &lt;36.013, Rockwell Automation CompactLogix 5480 &lt;37.011</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 34.015 and later.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 35.014 and later.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 36.013 and later.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 37.011 and later.</p>\n<p><strong>Mitigation</strong><br>Customers using the affected software who are not able to upgrade to one of the corrected versions should use Rockwell Automation's security best practices.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/835.html\">CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial republication of Rockwell Automation advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-02",
        "title": "Rockwell Automation Redundancy Module Configuration Tool",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges.</strong></p>\n<p>The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected:</p>\n<ul>\n<li>Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633)</li>\n<li>Redundancy Module Configuration Tool &gt;=9.00.00|&lt;=10.00.00 (CVE-2026-9634)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.3</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation Redundancy Module Configuration Tool</td>\n<td>Incorrect Default Permissions</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9633</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within the Redundancy Module Configuration Tool. The RM3ConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9633\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Redundancy Module Configuration Tool</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Redundancy Module Configuration Tool: 10.00.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has released Redundancy Module Configuration Tool version 10.01.00 for users to install.</p>\n<p><strong>Mitigation</strong><br>Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight).<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9634</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within the Redundancy Module Configuration Tool. The RMConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non-administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9634\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Redundancy Module Configuration Tool</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation Redundancy Module Configuration Tool: &gt;=9.00.00|&lt;=10.00.00</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has released Redundancy Module Configuration Tool version 10.01.00 for users to install.</p>\n<p><strong>Mitigation</strong><br>Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight).<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/276.html\">CWE-276 Incorrect Default Permissions</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Security Advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-01",
        "title": "Rockwell Automation RSLinx Classic",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product.</strong></p>\n<p>The following versions of Rockwell Automation RSLinx Classic are affected:</p>\n<ul>\n<li>RSLinx Classic &lt;=4.50 (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.6</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation RSLinx Classic</td>\n<td>Integer Overflow or Wraparound, Integer Underflow (Wrap or Wraparound), Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9621</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within RSLinx Classic. The security issue stems from improper handling of a malformed packet. A crafted CIP packet can cause the RSLinx Classic service to crash, requiring a restart of the service to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9621\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation RSLinx Classic</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation RSLinx Classic: &lt;=4.50</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has corrected the vulnerabilities in RSLinx Classic version 4.60.</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9622</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within RSLinx Classic. A crafted CIP packet targeting the Forward Close service can cause the RSLinx Classic service to crash, requiring a restart of the service to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9622\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation RSLinx Classic</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation RSLinx Classic: &lt;=4.50</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has corrected the vulnerabilities in RSLinx Classic version 4.60.</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/191.html\">CWE-191 Integer Underflow (Wrap or Wraparound)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9624</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within RSLinx Classic. A crafted CIP packet can cause the RSLinx Classic service to crash due to insufficient data length validation, requiring a restart of the service to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9624\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation RSLinx Classic</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation RSLinx Classic: &lt;=4.50</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has corrected the vulnerabilities in RSLinx Classic version 4.60.</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/191.html\">CWE-191 Integer Underflow (Wrap or Wraparound)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9625</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service security issue exists within RSLinx Classic. A crafted CIP packet with an oversized embedded message request can cause the RSLinx Classic service to crash, requiring a restart of the service to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9625\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation RSLinx Classic</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation RSLinx Classic: &lt;=4.50</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation has corrected the vulnerabilities in RSLinx Classic version 4.60.</p>\n<p><strong>Mitigation</strong><br>Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Mitigation</strong><br>For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation Advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-03",
        "title": "Rockwell Automation Logix Platform",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-244-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p>The following versions of Rockwell Automation Logix Platform are affected:</p>\n<ul>\n<li>ControlLogix 5580 &lt;=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637)</li>\n<li>CompactLogix 5380 &lt;=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637)</li>\n<li>GuardLogix 5580 &lt;=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637)</li>\n<li>Compact GuardLogix 5380 &lt;=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation Logix Platform</td>\n<td>Improper Restriction of Operations within the Bounds of a Memory Buffer</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-9637</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service vulnerability exists in the affected Logix platforms due to improper validation of input length during CIP message processing. This can result in a major nonrecoverable fault (MNRF), requiring a power cycle to recover.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-9637\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation Logix Platform</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation ControlLogix 5580 &lt;=V33, Rockwell Automation ControlLogix 5580 V34.011-V34.014, Rockwell Automation ControlLogix 5580 V35.011-V35.013, Rockwell Automation ControlLogix 5580 V36.011-V36.012, Rockwell Automation CompactLogix 5380 &lt;=V33, Rockwell Automation CompactLogix 5380 V34.011-V34.014, Rockwell Automation CompactLogix 5380 V35.011-V35.013, Rockwell Automation CompactLogix 5380 V36.011-V36.012, Rockwell Automation GuardLogix 5580 &lt;=V33, Rockwell Automation GuardLogix 5580 V34.011-V34.014, Rockwell Automation GuardLogix 5580 V35.011-V35.013, Rockwell Automation GuardLogix 5580 V36.011-V36.012, Rockwell Automation Compact GuardLogix 5380 &lt;=V33, Rockwell Automation Compact GuardLogix 5380 V34.011-V34.014, Rockwell Automation Compact GuardLogix 5380 V35.011-V35.013, Rockwell Automation Compact GuardLogix 5380 V36.011-V36.012</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version V37.011.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 34.015.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 35.014.</p>\n<p><strong>Vendor fix</strong><br>Rockwell Automation recommends users update to firmware version 36.013.</p>\n<p><strong>Mitigation</strong><br>Customers using the affected software who are not able to upgrade to one of the corrected versions should use Rockwell Automation's security best practices.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/119.html\">CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-01</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-01</td>\n<td>1</td>\n<td>Initial republication of Rockwell Automation advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 01 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 01 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/08/31/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/08/31/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation. &nbsp;</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81578\" target=\"_blank\"><u>CVE-2026-81578</u></a> PaperCut NG/MF Missing Authentication for Critical Function Vulnerability&nbsp;</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82078\" target=\"_blank\"><u>CVE-2026-82078</u></a> PaperCut NG/MF Unsafe Reflection Vulnerability&nbsp;</li>\n</ul>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\"><u>Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</u></a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\"><u>KEV Catalog vulnerabilities</u></a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\" target=\"_blank\"><u>specified criteria</u></a>.&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW211148847 BCX8\">\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\"><u>KEV Nomination Form</u></a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Mon, 31 Aug 26 12:00:00 +0000",
        "last_updated": "Mon, 31 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-03",
        "title": "Mitsubishi Electric Multiple FA Products (Update D)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-128-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition, a timeout error, or a communication delay by sending a specially crafted UDP packet to the product.</strong></p>\n<p>The following versions of Mitsubishi Electric Multiple FA Products (Update D) are affected:</p>\n<ul>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16D &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16T &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE &lt;=09 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4 &lt;=07 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4 &lt;=07 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4 &lt;=07 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4 &lt;=07 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41P01 01 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41D01 01 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41PD02 01 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300 &lt;=1.08J (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60 &lt;=1.08J (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2 &lt;=26 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP &lt;=10 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX &lt;=05 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series Ethernet Interface Module RJ71EN71 &lt;=85 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2GACP610-60 &lt;=05 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2KT-NPETNG51 &lt;=05 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS &lt;=1.020 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET &lt;=1.200 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP &lt;=1.106 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CPU module R04ENCPU (Network Part) &lt;=85 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CPU module R08ENCPU (Network Part) &lt;=85 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CPU module R16ENCPU (Network Part) &lt;=85 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CPU module R32ENCPU (Network Part) &lt;=85 (CVE-2025-3511)</li>\n<li>Mitsubishi Electric MELSEC iQ-R Series CPU module R120ENCPU (Network Part) &lt;=85 (CVE-2025-3511)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric Multiple FA Products (Update D)</td>\n<td>Improper Validation of Specified Quantity in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-3511</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A denial-of-service (DoS) vulnerability due to Improper Validation of Specified Quantity in Input (CWE-1284) exists in the Ethernet function of multiple FA products. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted UDP packet if CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, NZ2GN2B1-16TE, CC-Link IE TSN Analog-Digital Converter modules NZ2GN2S-60AD4, NZ2GN2B-60AD4, CC-Link IE TSN Digital-Analog Converter modules NZ2GN2S-60DA4 and NZ2GN2B-60DA4, CC-Link IE TSN FPGA modules NZ2GN2S-D41P01, NZ2GN2S-D41D01, NZ2GN2S-D41PD02, CC-Link IE TSN Remote Station Communication LSIs CP620 with GbE-PHY NZ2GACP620-300, and NZ2GACP620-60 does not receive a valid UDP packet within 3 seconds. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition on MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, MELSEC iQ-R Series Ethernet Interface Module RJ71EN71, CC-Link IE TSN master/local Station Communication LSIs CP610 NZ2GACP610-60, NZ2KT-NPETNG51, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS, MELSEC iQ-R Series CPU module R04ENCPU (Network part), R08ENCPU (Network part), R16ENCPU (Network part), R32ENCPU (Network part), and R120ENCPU (Network part), by sending a specially crafted UDP packet. Or this vulnerability could allow a remote attacker to cause a communication delay in Simple CPU communication on MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET and FX5-ENET/IP Ethernet Module FX5-ENET/IP, by sending a specially crafted UDP packet. A system reset of the product is required for recovery in all cases above. Additionally, this vulnerability could allow a remote attacker to cause a timeout error in CC-Link IEF Basic communication on MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET and FX5-ENET/IP Ethernet Module FX5-ENET/IP, by sending a specially crafted UDP packet. Even if a timeout error occurs, communication will be restored once the affected product starts receiving valid UDP packets.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-3511\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric Multiple FA Products (Update D)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16D: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16T: &lt;=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE: &lt;=09, Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4: &lt;=07, Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4: &lt;=07, Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4: &lt;=07, Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4: &lt;=07, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41P01: 01, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41D01: 01, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41PD02: 01, Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300: &lt;=1.08J, Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60: &lt;=1.08J, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2: &lt;=26, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP: &lt;=10, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX: &lt;=05, Mitsubishi Electric MELSEC iQ-R Series Ethernet Interface Module RJ71EN71: &lt;=85, Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2GACP610-60: &lt;=05, Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2KT-NPETNG51: &lt;=05, Mitsubishi Electric MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS: &lt;=1.020, Mitsubishi Electric MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET: &lt;=1.200, Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: &lt;=1.106, Mitsubishi Electric MELSEC iQ-R Series CPU module R04ENCPU (Network Part): &lt;=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R08ENCPU (Network Part): &lt;=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R16ENCPU (Network Part): &lt;=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R32ENCPU (Network Part): &lt;=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R120ENCPU (Network Part): &lt;=85</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 10 or later for CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, and NZ2GN2B1-16TE. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf.\"<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 08 or later for CC-Link IE TSN Analog-Digital Converter modules NZ2GN2S-60AD4 and NZ2GN2B-60AD4. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 08 or later for CC-Link IE TSN Digital-Analog Converter modules NZ2GN2S-60DA4 and NZ2GN2B-60DA4. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 02 or later for CC-Link IE TSN FPGA modules NZ2GN2S-D41P01, NZ2GN2S-D41D01, and NZ2GN2S-D41PD02. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.09K or later for CC-Link IE TSN Remote Station Communication LSIs CP620 with GbE-PHY NZ2GACP620-300 or NZ2GACP620-60. Please download the CP620 sample code from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 28 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 13 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 07 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 86 or later for MELSEC iQ-R Series Ethernet Interface Module RJ71EN71. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 06 or later for CC-Link IE TSN master/local Station Communication LSIs CP610 NZ2GACP610-60 and NZ2KT-NPETNG51. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.030 or later for MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.210 or later for MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed version 1.107 or later for MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Vendor fix</strong><br>Mitsubishi Electric is releasing fixed network part firmware version 86 or later for MELSEC iQ-R Series CPU module R04ENCPU (Network part), R08ENCPU (Network part), R16ENCPU (Network part), R32ENCPU (Network part), and R120ENCPU (Network part). Please download the fixed update file from the link \"https://www.mitsubishielectric.com/fa/download/index.html\" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends using within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends restricting physical access to the products and the LAN to which they are connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends installing anti-virus software on your PC that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1284.html\">CWE-1284 Improper Validation of Specified Quantity in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric discovering this vulnerability</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric 2025-001 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-04-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-04-25</td>\n<td>1</td>\n<td>CISA Republication - Initial Republication</td>\n</tr>\n<tr>\n<td>2025-04-25</td>\n<td>2</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2025-10-09</td>\n<td>3</td>\n<td>RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, RJ71EN71, NZ2GACP610-60, and NZ2KT-NPETNG51 have been added as affected products and fixed products, and the \"remediations\" was revised.</td>\n</tr>\n<tr>\n<td>2025-10-09</td>\n<td>4</td>\n<td>CISA Republication - Update A - Update to Affected products, Impact, Countermeasures for Customers, Countermeasures for Products have been revised. The affected products RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, RJ71EN71, NZ2GACP610-60 and NZ2KT-NPETNG51 have been added.</td>\n</tr>\n<tr>\n<td>2026-02-03</td>\n<td>5</td>\n<td>CISA Republication - Update B - Update to Summary, Affected products, and Remediations have been revised. The affected products FX5-CCLGN-MS, FX5-ENET, and FX5-ENET/IP have been added.</td>\n</tr>\n<tr>\n<td>2026-02-03</td>\n<td>6</td>\n<td>FX5-CCLGN-MS, AFX5-ENET, and AFX5-ENET/IP have been added as affected products and fixed products, and the \"remediations\" was revised.</td>\n</tr>\n<tr>\n<td>2026-04-23</td>\n<td>7</td>\n<td>Added FX5-CCLGN-MS and FX5-ENET/IP have been added as fixed products, and the \"remediations\" was revised.</td>\n</tr>\n<tr>\n<td>2026-04-30</td>\n<td>8</td>\n<td>CISA Republication - Update C - Added FX5-CCLGN-MS and FX5-ENET/IP that have been fixed to Countermeasures for Products. Affected products, Countermeasures for Customers, and Countermeasures for Products have been revised.</td>\n</tr>\n<tr>\n<td>2026-08-27</td>\n<td>9</td>\n<td>R04ENCPU (Network Part), R08RNCPU (Network Part), R16ENCPU (Network Part), R32ENCPU (Network Part), and R12ENCPU (Network Part) have been added as affected products and fixed products, and the \"remediations\" was revised.</td>\n</tr>\n<tr>\n<td>2026-08-27</td>\n<td>10</td>\n<td>CISA Republication update based on Mitsubishi Electric 2025-001 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "title": "Mitsubishi Electric CNC Series (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products.</strong></p>\n<p>The following versions of Mitsubishi Electric CNC Series (Update A) are affected:</p>\n<ul>\n<li>Mitsubishi Electric M800VW (BND-2051W000) &lt;=BB (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M800VS (BND-2052W000) &lt;=BB (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M80V (BND-2053W000) &lt;=BB (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M80VW (BND-2054W000) &lt;=BB (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M800W (BND-2005W000) &lt;=FM (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M800S (BND-2006W000) &lt;=FM (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M80 (BND-2007W000) &lt;=FM (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M80W (BND-2008W000) &lt;=FM (CVE-2025-2399)</li>\n<li>Mitsubishi Electric E80 (BND-2009W000) &lt;=FM (CVE-2025-2399)</li>\n<li>Mitsubishi Electric C80 (BND-2036W000) vers:all/* (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M750VW (BND-1015W002) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M730VW (BND-1015W000) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M720VW (BND-1015W000) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M750VS (BND-1012W002) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M730VS (BND-1012W000) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M720VS (BND-1012W000) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric M70V (BND-1018W000) &lt;=LJ (CVE-2025-2399)</li>\n<li>Mitsubishi Electric E70 (BND-1022W000) &lt;=LJ (CVE-2025-2399)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.9</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric CNC Series (Update A)</td>\n<td>Improper Validation of Specified Index, Position, or Offset in Input</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-2399</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-2399\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric CNC Series (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric M800VW (BND-2051W000): &lt;=BB, Mitsubishi Electric M800VS (BND-2052W000): &lt;=BB, Mitsubishi Electric M80V (BND-2053W000): &lt;=BB, Mitsubishi Electric M80VW (BND-2054W000): &lt;=BB, Mitsubishi Electric M800W (BND-2005W000): &lt;=FM, Mitsubishi Electric M800S (BND-2006W000): &lt;=FM, Mitsubishi Electric M80 (BND-2007W000): &lt;=FM, Mitsubishi Electric M80W (BND-2008W000): &lt;=FM, Mitsubishi Electric E80 (BND-2009W000): &lt;=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): &lt;=LJ, Mitsubishi Electric M730VW (BND-1015W000): &lt;=LJ, Mitsubishi Electric M720VW (BND-1015W000): &lt;=LJ, Mitsubishi Electric M750VS (BND-1012W002): &lt;=LJ, Mitsubishi Electric M730VS (BND-1012W000): &lt;=LJ, Mitsubishi Electric M720VS (BND-1012W000): &lt;=LJ, Mitsubishi Electric M70V (BND-1018W000): &lt;=LJ, Mitsubishi Electric E70 (BND-1022W000): &lt;=LJ</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW (BND-2051W000), M800VS (BND-2052W000), M80V (BND-2053W000), and M80VW (BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (FN or later) for Mitsubishi Electric M800W (BND-2005W000), M800S (BND-2006W000), M80 (BND-2007W000), M80W (BND-2008W000), and E80 (BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Vendor fix</strong><br>Please apply the fixed version (LK or later) for Mitsubishi Electric M750VW (BND-1015W002), M730VW (BND-1015W000), M720VW (BND-1015W000), M750VS (BND-1012W002), M730VS (BND-1012W000), M720VS (BND-1012W000), M70V (BND-1018W000), and E70 (BND-1022W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product which can be downloaded from the link \"https://www.mitsubishielectric.com/fa/download/index.html \": M800V/M80V Series Instruction Manual \"16. Appendix 3 IP Address Filter Setting Function\", M800/M80/E80 Series Instruction Manual \"15. Appendix 2 IP Address Filter Setting Function\".<br><a href=\"https://www.mitsubishielectric.com/fa/download/index.html\">https://www.mitsubishielectric.com/fa/download/index.html</a></p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1285.html\">CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mitsubishi Electric reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric 2025-022 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-03-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-03-10</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-03-19</td>\n<td>2</td>\n<td>CISA Republication - Initial CISA Republication of Mitsubishi Electric V20250121-001#02 advisory</td>\n</tr>\n<tr>\n<td>2026-08-27</td>\n<td>3</td>\n<td>Removed Software Tools NC Trainer2 and Software Tools NC Trainer2 plus, from affected products. And added M700V/M70V/E70 Series as fixed products.</td>\n</tr>\n<tr>\n<td>2026-08-27</td>\n<td>4</td>\n<td>CISA Republication update based on Mitsubishi Electric 2025-022 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-05",
        "title": "Ebyte NA111-M",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-239-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to fully compromise the device.</strong></p>\n<p>The following versions of Ebyte NA111-M are affected:</p>\n<ul>\n<li>NA111-M Firmware 9013-2-17 (CVE-2026-73125, CVE-2026-76179, CVE-2026-75814, CVE-2026-76940, CVE-2026-77966, CVE-2026-73809, CVE-2026-71187, CVE-2026-75548, CVE-2026-69658, CVE-2026-76133, CVE-2026-73819, CVE-2026-77975, CVE-2026-77977)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Ebyte</td>\n<td>Ebyte NA111-M</td>\n<td>Missing Authentication for Critical Function, Use of GET Request Method With Sensitive Query Strings, Cross-Site Request Forgery (CSRF), Improper Restriction of Excessive Authentication Attempts, Missing Authorization, Cleartext Transmission of Sensitive Information, Use of Client-Side Authentication, Improper Restriction of Rendered UI Layers or Frames, Use of a Broken or Risky Cryptographic Algorithm, Weak Authentication, Cleartext Storage of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-73125</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ebyte device web management interface does not consistently enforce authentication before granting access to administrative functionality. An unauthenticated remote attacker could access sensitive configuration information, modify device settings, or disrupt availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-73125\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-76179</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An improper protection of authentication tokens vulnerability exists in certain Ebyte gateway products. Authentication tokens used by the web management interface are insufficiently protected during client-side session handling, which may allow an attacker with access to exposed session information to obtain and reuse a valid token. Successful exploitation could allow an attacker to impersonate an authenticated user and gain unauthorized access to device management functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76179\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/598.html\">CWE-598 Use of GET Request Method With Sensitive Query Strings</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-75814</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ebyte device does not adequately verify the origin or authenticity of requests submitted to the web management interface. An unauthenticated remote attacker could persuade an authenticated administrator to visit a crafted page, causing unauthorized configuration changes or a disruption of device availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-75814\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/352.html\">CWE-352 Cross-Site Request Forgery (CSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-76940</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected Ebyte device does not restrict repeated authentication attempts through rate limiting or account lockout mechanisms. This could allow an attacker to perform automated authentication attacks against deployments that rely on password based authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76940\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77966</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product does not provide separation between limited and administrative management functions. A low privileged authenticated attacker could access security sensitive configuration functions and modify settings that affect the confidentiality, integrity, or availability of the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77966\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-73809</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A cleartext transmission of sensitive information vulnerability exists in certain Ebyte gateway products. The web management interface does not adequately protect sensitive communications using transport-layer encryption. An attacker with access to network traffic could intercept authentication or session-related information transmitted between a user and the affected device. Successful exploitation could result in disclosure of sensitive information and unauthorized access to device management functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-73809\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-71187</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Ebyte device relies on client side authentication logic that can be reproduced by unauthenticated users. An attacker may generate valid authentication requests and bypass authentication to obtain administrative access to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-71187\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/603.html\">CWE-603 Use of Client-Side Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-75548</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected Ebyte device web management interface does not restrict the interface from being rendered within an external frame. An unauthenticated remote attacker could use a crafted webpage to mislead an authenticated administrator into initiating unintended configuration changes or disruptive actions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-75548\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1021.html\">CWE-1021 Improper Restriction of Rendered UI Layers or Frames</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-69658</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>MQTT credentials and control traffic are transmitted in cleartext, exposing sensitive information to network-level attackers. This may enable unauthorized device impersonation and disruption of messaging functions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-69658\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-76133</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product uses a deprecated hashing algorithm in an authentication-related operation. Under conditions where an attacker can manipulate or predict the authentication exchange, the weak construction may reduce the assurance provided by the authentication mechanism and facilitate unauthorized access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76133\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/327.html\">CWE-327 Use of a Broken or Risky Cryptographic Algorithm</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-73819</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product's vendor configuration utility permits access to administrative functions without verifying the operator's identity under certain credential conditions. An unauthenticated attacker on the adjacent network could modify critical settings or change access credentials, potentially preventing legitimate administrators from managing the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-73819\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/1390.html\">CWE-1390 Weak Authentication</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77975</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product exports administrative credentials and other sensitive configuration information without adequate protection. An unauthenticated attacker on the adjacent network who can obtain an exported configuration file could recover valid credentials and use them to access the device or similarly configured systems.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77975\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77977</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product's vendor configuration utility does not require authentication before allowing certain disruptive administrative actions when default credentials remain configured. An unauthenticated attacker on the adjacent network could reboot the device or restore factory settings, resulting in a loss of configuration and service availability.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77977\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Ebyte NA111-M</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Ebyte</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ebyte NA111-M Firmware: 9013-2-17</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Ebyte acknowledged receipt of the reported vulnerabilities and indicated that a patch was under development. However, the vendor has not responded to subsequent requests for coordination, and CISA has not been informed of the status or availability of the patch. Users are encouraged to reach out to Ebyte for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jithin Nambiar J reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-27</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-03",
        "title": "Rockwell Automation OTTO Fleet Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-239-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could reduce the computational cost required for an attacker to perform offline brute-force attacks against stored password hashes.</strong></p>\n<p>The following versions of Rockwell Automation OTTO Fleet Manager are affected:</p>\n<ul>\n<li>OTTO Fleet Manager &lt;=V2.36.2 (CVE-2026-75112)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.8</td>\n<td>Rockwell Automation</td>\n<td>Rockwell Automation OTTO Fleet Manager</td>\n<td>Use of Password Hash With Insufficient Computational Effort</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-75112</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A security issue exists within OTTO Fleet Manager. The vulnerability stems from the use of an insufficient work factor in the bcrypt password hashing implementation, which could reduce the computational cost required for an attacker to perform offline brute-force attacks against stored password hashes. If an attacker gains access to an unencrypted system backup, the weakly hashed credentials could be more easily compromised.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-75112\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Rockwell Automation OTTO Fleet Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Rockwell Automation</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Rockwell Automation OTTO Fleet Manager: &lt;=V2.36.2</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Rockwell Automation has addressed this vulnerability in software version 2.36.3.<br><a href=\"https://file-share.ottomotors.com/login\">https://file-share.ottomotors.com/login</a></p>\n<p><strong>Mitigation</strong><br>Users of the affected software who are not able to upgrade to the corrected version or apply the mitigations should use Rockwell Automation's security best practices.<br><a href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight</a></p>\n<p><strong>Vendor fix</strong><br>See Rockwell Automation security advisory SD1791 for more information about this issue and instructions to enable encrypted system backup in OTTO Fleet Manager.<br><a href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1791.html\">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1791.html</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding the security issue(s) above and how to mitigate them, contact Rockwell Automation support.<br><a href=\"https://ottomotors.com/otto-care/\">https://ottomotors.com/otto-care/</a></p>\n<p><strong>Mitigation</strong><br>If you have any questions regarding this disclosure, please email Rockwell Automation PSIRT: rasecure@ra.rockwell.com<br><a href=\"mailto:rasecure@ra.rockwell.com\">mailto:rasecure@ra.rockwell.com</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/916.html\">CWE-916 Use of Password Hash With Insufficient Computational Effort</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N\">CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Rockwell Automation reported this vulnerability to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-27</td>\n<td>1</td>\n<td>Initial Republication of Rockwell Automation SD1791.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-01",
        "title": "Xiiaozet LK100W",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-239-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to take control over the device.</strong></p>\n<p>The following versions of Xiiaozet LK100W are affected:</p>\n<ul>\n<li>LK100W &lt;2.1.240 (CVE-2026-78037, CVE-2026-78239, CVE-2026-76943)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Xiiaozet</td>\n<td>Xiiaozet LK100W</td>\n<td>Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Authentication Bypass Using an Alternate Path or Channel</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-78037</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Xiiaozet LK100W is vulnerable to OS command injection through its web-based management interface. An authenticated attacker may be able to execute arbitrary operating system commands with elevated privileges, potentially resulting in unauthorized access to sensitive information or complete device compromise.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-78037\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Xiiaozet LK100W</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Xiiaozet</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Xiiaozet LK100W: &lt;2.1.240</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Xiiaozet recommends users update to v2.1.240.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-78239</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Xiiaozet LK100W exposes a critical management function that can be invoked without authentication, allowing a remote attacker to enable administrative services that should be restricted. Successful exploitation may permit unauthorized access to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-78239\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Xiiaozet LK100W</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Xiiaozet</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Xiiaozet LK100W: &lt;2.1.240</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Xiiaozet recommends users update to v2.1.240.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-76943</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Xiiaozet LK100Wt contains an authentication weakness within an administrative service that may allow an attacker to bypass intended access controls and obtain command execution capabilities. Successful exploitation could allow unauthorized interaction with privileged functionality and may lead to complete device compromise.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76943\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Xiiaozet LK100W</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Xiiaozet</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Xiiaozet LK100W: &lt;2.1.240</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Xiiaozet recommends users update to v2.1.240.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/288.html\">CWE-288 Authentication Bypass Using an Alternate Path or Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Byron Guernsey of Okachobi, LLC reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-27</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-04",
        "title": "Applied Systems Engineering ASE2000 V2 Communications Test Set",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-239-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to read or write arbitrary local files, cause the application to issue outbound network requests, or intercept the connection to impersonate the trusted peer, complete the TLS handshake, and read or modify the protected communications.</strong></p>\n<p>The following versions of Applied Systems Engineering ASE2000 V2 Communications Test Set are affected:</p>\n<ul>\n<li>ASE2000 &gt;=2.25|&lt;=2.37 (CVE-2018-1285, CVE-2026-18717)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Applied Systems Engineering</td>\n<td>Applied Systems Engineering ASE2000 V2 Communications Test Set</td>\n<td>Improper Restriction of XML External Entity Reference, Improper Certificate Validation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-1285</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>ASE2000 versions 2.25 through 2.37 is vulnerable to Apache log4net versions before 2.0.10 do not disable XML external entities when parsing log4net configuration files. This allows for XXE based attacks in applications that accept attacker controlled log4net configuration files.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-1285\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Applied Systems Engineering ASE2000 V2 Communications Test Set</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Applied Systems Engineering</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Applied Systems Engineering ASE2000: &gt;=2.25|&lt;=2.37</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ASE/Kalkitech provides an upgraded version 2.38 that fixes both vulnerabilities and customers are advised to upgrade to version 2.38. In version 2.38 the bundled log4net library is upgraded to version 3.3.1.0, and the IEC 60870-5-104 TLS client certificate validation logic is corrected to ensure proper validation of certificate error conditions.</p>\n<p><strong>Vendor fix</strong><br>All customers running ASE2000 versions 2.25 through 2.37 are affected by this issue and are required to upgrade to version 2.38 or later to apply the security fix. Upgrade instructions and user documentation are available at www.ase-systems.com. For detailed, step-by-step guidance on upgrading to the latest version and patching the impacted components, please contact our support team at support@ase-systems.com.<br><a href=\"http://www.ase-systems.com\">http://www.ase-systems.com</a></p>\n<p><strong>Vendor fix</strong><br>All customers running ASE2000 versions 2.25 through 2.37 are affected by this issue and are required to upgrade to version 2.38 or later to apply the security fix. Upgrade instructions and user documentation are available at www.ase-systems.com. For detailed, step-by-step guidance on upgrading to the latest version and patching the impacted components, please contact our support team at support@ase-systems.com.<br><a href=\"mailto:support@ase-systems.com\">mailto:support@ase-systems.com</a></p>\n<p><strong>Mitigation</strong><br>Until the upgrade can be applied, the following interim measures reduce exposure:</p>\n<p><strong>Vendor fix</strong><br>Restrict write access to the ASE2000 installation directory and its configuration files to trusted administrators only.</p>\n<p><strong>Vendor fix</strong><br>Avoid using IEC 60870-5-104 over TLS across untrusted or shared networks; place ASE2000 hosts on an isolated, segmented network reachable only by intended peers.</p>\n<p><strong>Mitigation</strong><br>Ensure the host is protected by a network firewall.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/611.html\">CWE-611 Improper Restriction of XML External Entity Reference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-18717</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>ASE2000 2.35 through 2.37 is vulnerable to an improper certificate validation vulnerability, which may allow an attacker to impersonate the trusted peer, complete the TLS handshake, and read or modify protected communications.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-18717\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Applied Systems Engineering ASE2000 V2 Communications Test Set</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Applied Systems Engineering</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Applied Systems Engineering ASE2000: &gt;=2.25|&lt;=2.37</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ASE/Kalkitech provides an upgraded version 2.38 that fixes both vulnerabilities and customers are advised to upgrade to version 2.38. In version 2.38 the bundled log4net library is upgraded to version 3.3.1.0, and the IEC 60870-5-104 TLS client certificate validation logic is corrected to ensure proper validation of certificate error conditions.</p>\n<p><strong>Vendor fix</strong><br>All customers running ASE2000 versions 2.25 through 2.37 are affected by this issue and are required to upgrade to version 2.38 or later to apply the security fix. Upgrade instructions and user documentation are available at www.ase-systems.com. For detailed, step-by-step guidance on upgrading to the latest version and patching the impacted components, please contact our support team at support@ase-systems.com.<br><a href=\"http://www.ase-systems.com\">http://www.ase-systems.com</a></p>\n<p><strong>Vendor fix</strong><br>All customers running ASE2000 versions 2.25 through 2.37 are affected by this issue and are required to upgrade to version 2.38 or later to apply the security fix. Upgrade instructions and user documentation are available at www.ase-systems.com. For detailed, step-by-step guidance on upgrading to the latest version and patching the impacted components, please contact our support team at support@ase-systems.com.<br><a href=\"mailto:support@ase-systems.com\">mailto:support@ase-systems.com</a></p>\n<p><strong>Mitigation</strong><br>Until the upgrade can be applied, the following interim measures reduce exposure:</p>\n<p><strong>Vendor fix</strong><br>Restrict write access to the ASE2000 installation directory and its configuration files to trusted administrators only.</p>\n<p><strong>Vendor fix</strong><br>Avoid using IEC 60870-5-104 over TLS across untrusted or shared networks; place ASE2000 hosts on an isolated, segmented network reachable only by intended peers.</p>\n<p><strong>Mitigation</strong><br>Ensure the host is protected by a network firewall.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/295.html\">CWE-295 Improper Certificate Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Enoch Wang reported these vulnerabilities to CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-27</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-02",
        "title": "All-Line Equipment Company Fuel-Boss",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-239-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-239-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow attackers to execute arbitrary commands or code remotely on affected systems.</strong></p>\n<p>The following versions of All-Line Equipment Company Fuel-Boss are affected:</p>\n<ul>\n<li>Fuel-Boss V1 Standard &gt;=|&lt;=PHP_7.1.5_7.1.5 (CVE-2018-19518, CVE-2019-11043)</li>\n<li>Fuel-Boss V1 Portal &gt;=|&lt;=PHP_7.1.5_7.1.5 (CVE-2018-19518, CVE-2019-11043)</li>\n<li>Fuel-Boss V1 Master/Slave &gt;=|&lt;=PHP_7.1.5_7.1.5 (CVE-2018-19518, CVE-2019-11043)</li>\n<li>Fuel-Boss V1 Backflush Systems &gt;=|&lt;=PHP_7.1.5_7.1.5 (CVE-2018-19518, CVE-2019-11043)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.7</td>\n<td>All-Line Equipment Company</td>\n<td>All-Line Equipment Company Fuel-Boss</td>\n<td>Improper Neutralization of Argument Delimiters in a Command ('Argument Injection'), Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Defense Industrial Base, Emergency Services, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2018-19518</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Fuel-Boss is vulnerable to the University of Washington IMAP Toolkit 2007f on UNIX, used in imap_open() in PHP and other products, launching an rsh command via the imap_rimap and tcp_aopen functions without preventing argument injection, which can allow remote attackers to execute arbitrary OS commands when an untrusted IMAP server name is supplied and rsh has been replaced by a program with different argument semantics such as ssh. This enables attacks through IMAP server names containing a \"-oProxyCommand\" argument, as well as a stack-based buffer overflow that may allow an attacker to remotely execute arbitrary code.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2018-19518\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>All-Line Equipment Company Fuel-Boss</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>All-Line Equipment Company</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>All-Line Equipment Company Fuel-Boss V1 Standard: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Portal: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Master/Slave: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Backflush Systems: &gt;=|&lt;=PHP_7.1.5_7.1.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Fixes are available for the Fuel-Boss V1 Standard and Fuel-Boss V1 Portal. Please contact All-Line Equipment Company (866-356-3336) for instructions on how to receive these fixes.</p>\n<p><strong>Vendor fix</strong><br>Fixes are not yet available for the Fuel-Boss V1 Master/Slave.</p>\n<p><strong>Vendor fix</strong><br>No fix is planned for Fuel-Boss V1 Backflush Systems.</p>\n<p><strong>Mitigation</strong><br>All-Line Equipment Company recommends either taking products that are not fixed off the Internet or restricting the IP addresses that can access them at the router level.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/88.html\">CWE-88 Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2019-11043</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Fuel-Boss running versions up to and including PHP 7.1.5 is vulnerable because certain FPM configurations allow the FPM module to write past allocated buffers into space reserved for FCGI protocol data, thereby creating a possible remote code execution condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-11043\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>All-Line Equipment Company Fuel-Boss</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>All-Line Equipment Company</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>All-Line Equipment Company Fuel-Boss V1 Standard: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Portal: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Master/Slave: &gt;=|&lt;=PHP_7.1.5_7.1.5, All-Line Equipment Company Fuel-Boss V1 Backflush Systems: &gt;=|&lt;=PHP_7.1.5_7.1.5</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Fixes are available for the Fuel-Boss V1 Standard and Fuel-Boss V1 Portal. Please contact All-Line Equipment Company (866-356-3336) for instructions on how to receive these fixes.</p>\n<p><strong>Vendor fix</strong><br>Fixes are not yet available for the Fuel-Boss V1 Master/Slave.</p>\n<p><strong>Vendor fix</strong><br>No fix is planned for Fuel-Boss V1 Backflush Systems.</p>\n<p><strong>Mitigation</strong><br>All-Line Equipment Company recommends either taking products that are not fixed off the Internet or restricting the IP addresses that can access them at the router level.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/120.html\">CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>These vulnerabilities were anonymously reported to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>These vulnerabilities have a high attack complexity.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-27</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-27</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/08/27/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Three Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/08/27/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added three new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<div class=\"ListContainerWrapper SCXW183571888 BCX8\">\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2023-49105\" target=\"_blank\">CVE-2023-49105</a> ownCloud Improper Authentication Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-53362\" target=\"_blank\">CVE-2026-53362</a> Linux Kernel Unspecified Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-66384\" target=\"_blank\">CVE-2026-66384</a> JFrog Artifactory Improper Limitation of a Pathname to a Restricted Directory Vulnerability&nbsp;</li>\n</ul>\n</div>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a class=\"ext\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 27 Aug 26 12:00:00 +0000",
        "last_updated": "Thu, 27 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/cisa-vulnerability-review",
        "title": "CISA Vulnerability Review",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/cisa-vulnerability-review",
        "summary": "<p>Most compromises do not rely on advanced techniques or cutting-edge tools. Cyber threat actors scan the internet looking for exposed, well-known software vulnerabilities to exploit. Basic security failures enable most compromises and organizations can reduce their risk by addressing these underlying weaknesses and prioritizing vulnerabilities for action based on the risk they pose.</p>\n<p>The <a href=\"https://www.cisa.gov/sites/default/files/2026-08/cisa-vulnerability-review-fy-2024-2025-508.pdf\"><em>CISA Vulnerability Review</em></a><em>&nbsp;</em>provides organizations with critical insights into the root causes of insecure software and practical steps they can take to address these flaws to prevent exploitation. Analyzing CISA and open source data from fiscal years 2024 and 2025, the review establishes a baseline of today\u2019s vulnerability landscape before AI-enabled vulnerability discovery becomes more widespread. The review demonstrates the importance of&nbsp;<a href=\"https://www.cisa.gov/securebydesign\">Secure by Design</a> principles in shifting cybersecurity efforts from reacting to threat actors to proactively fixing preventable software flaws.</p>\n<p>The review also identifies common software weaknesses that contribute to exploitable vulnerabilities and details practices software producers can use to prevent these weaknesses from recurring. By examining the patterns across vulnerability data, the review helps organizations focus on systemic improvements that can reduce entire classes of vulnerabilities rather than addressing individual vulnerabilities only after they are discovered.</p>\n<p>Additionally, the review shows organizations how to prioritize vulnerabilities for action using the framework outlined in&nbsp;<a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk\">Binding Operational Directive 26-04: <em>Prioritizing Security Based on Risk</em></a>. This framework evaluates vulnerabilities using four key criteria: exposure status,&nbsp;<a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">Known Exploited Vulnerability (KEV) Catalog</a> status, potential for automated exploitation, and technical impact.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 26 Aug 26 12:00:00 +0000",
        "last_updated": "Wed, 26 Aug 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/08/26/cisa-adds-six-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Six Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/08/26/cisa-adds-six-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added six new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<div class=\"ListContainerWrapper SCXW183571888 BCX8\">\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-3246\" target=\"_blank\">CVE-2015-3246</a> Red Hat Libuser Race Condition Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2015-5287\" target=\"_blank\">CVE-2015-5287</a> Red Hat Automatic Bug Reporting Tool Privilege Escalation Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2019-1068\" target=\"_blank\">CVE-2019-1068</a> Microsoft SQL Server Remote Code Execution Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2021-23758\" target=\"_blank\">CVE-2021-23758</a> Ajax.NET Professional Deserialization of Untrusted Data Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2022-0995\" target=\"_blank\">CVE-2022-0995</a> Linux Kernel Out-of-Bounds Write Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-8452\" target=\"_blank\">CVE-2026-8452</a> Citrix NetScaler ADC and NetScaler Gateway Improper Restriction of Operations within the Bounds of a Memory Buffer Vulnerability</li>\n</ul>\n</div>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a class=\"ext\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 26 Aug 26 12:00:00 +0000",
        "last_updated": "Wed, 26 Aug 26 12:00:00 +0000"
    }
]