[
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/18/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/18/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-39964\" target=\"_blank\">CVE-2025-39964</a> Linux Kernel Race Condition Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-53266\" target=\"_blank\">CVE-2026-53266</a> Linux Kernel Out-of-Bounds Write Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.&nbsp;</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 18 Sep 26 12:00:00 +0000",
        "last_updated": "Fri, 18 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/18/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-39682\" target=\"_blank\">CVE-2025-39682</a> Linux Kernel Improper Check for Unusual or Exceptional Conditions Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a class=\"ext\" href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 18 Sep 26 12:00:00 +0000",
        "last_updated": "Fri, 18 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-06",
        "title": "ABB Ability Edgenius",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>ABB is aware of public reports of a vulnerability CVE\u20112026\u201131431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE\u20112026\u201131431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control of the system</strong></p>\n<p>The following versions of ABB Ability Edgenius are affected:</p>\n<ul>\n<li>Ability Edgenius &gt;=3.2.0.0|&lt;3.2.4.1, 3.2.4.1 (CVE-2026-31431)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.8</td>\n<td>ABB</td>\n<td>ABB Ability Edgenius</td>\n<td>Incorrect Resource Transfer Between Spheres</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Water and Wastewater, Chemical</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-31431</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. The issue originates in the Linux kernel\u2019s cryptographic subsystem and impacts kernels used by most major Linux distributions released since 2017.Successful exploitation requires local code execution, however, in shared, containerized, or multi\u2011tenant environments this may increase the security risk.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-31431\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ABB Ability Edgenius</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ABB</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ABB Ability Edgenius &gt;=3.2.0.0|&lt;3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>The problem is corrected in the following product versions: - Edgenius 3.2.4.1 ABB recommends that customers apply the update at earliest convenience.</p>\n<p><strong>Mitigation</strong><br>Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Refer to section General security recommendations for further advise on how to keep your system secure. Recommended mitigation factors - Limit access to ssh or cockpit - By default, no additional lower privilege users are present on Edgenius installations.</p>\n<p><strong>Mitigation</strong></p>\n<p>For more information see the associated ABB PSIRT security advisory 7PAA024620 <a href=\"https://search.abb.com/library/Download.aspx?DocumentID=7PAA024620&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=Launch\">ABB CYBERSECURITY ADVISORY - PDF Version </a>, <a href=\"https://psirt.abb.com/csaf/2026/7paa024620.json\">ABB CYBERSECURITY ADVISORY - CSAF Version </a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/669.html\">CWE-669 Incorrect Resource Transfer Between Spheres</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>ABB PSIRT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Frequently Asked Questions</h2>\n<p>What causes the vulnerability? - A flaw was found in the Linux kernel's algif_aead cryptographic algorithm interface. An incorrect 'in-place operation' was introduced, where the source and destination data mappings were different. This could lead to unexpected behavior or data integrity issues during cryptographic operations, potentially impacting the reliability of encrypted communications. What is Edgenius? - ABB Ability\u2122 Edgenius is an edge computing platform that - Connects to control systems, devices, and equipment - Collects and contextualizes operational data - Hosts applications that deliver real-time insights and AI-driven recommendations What might an attacker use the vulnerability to do? - Successful exploitation could enable a local user attacker to gain administrative control of the system node, execute arbitrary code, or cause the node to become unavailable. How could an attacker exploit the vulnerability? - An attacker could exploit this vulnerability after obtaining local access to the system. By invoking the Linux kernel\u2019s affected cryptographic interface (algif_aead), the attacker can trigger incorrect memory handling in the kernel. This allows the attacker to escalate privileges from a normal user to full administrative (root) access on the affected system node Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have local access (physical access or through valid SSH credentials) to an affected system node. What does the update do? - The update resolves the issue by incorporating the security update of the Linux kernel. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited for Edgenius when this security advisory was originally issued.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of ABB PSIRT <a href=\"https://search.abb.com/library/download.aspx?documentid=7paa024620&amp;languagecode=en&amp;documentpartid=&amp;action=launch\">7PAA024620</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-06-25</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-06-25</td>\n<td>1</td>\n<td>Initial version.</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>2</td>\n<td>Initial CISA Republication of ABB PSIRT 7PAA024620 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-07",
        "title": "Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-211-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.</strong></p>\n<p>The following versions of Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A) are affected:</p>\n<ul>\n<li>Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-16 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-64 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-128 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-256 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-N32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-P32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-N32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-P32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-N32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-P32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-N32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-P32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-N32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-P32 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Master/local module RJ71GN11-T2 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Master/local module RJ71GN11-SX vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Master/local module RJ71GN11-EIP vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Master/local module FX5-CCLGN-MS vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-SX vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-T2 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78G4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78G8 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78G16 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78G64 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78GHV vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module RD78GHW vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module FX5-40SSC-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion module FX5-80SSC-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G16 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion Control Board MR-EM441G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-32D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-32T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-32TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-32DT vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-32DTE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-32D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-32T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-32TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-32DT vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-32DTE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GNCF1-32D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GNCF1-32T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GNCE3-32D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GNCE3-32DT vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A4-16D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A4-16DE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A2-16T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A2-16TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A42-16DT vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN12A42-16DTE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-16D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-16T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2S1-16TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-16D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-16T vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module NZ2GN2B1-16TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D-K vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE-K vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE-K vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-14DT vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-16DTE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Analog-Digital converter module NZ2GN2S-60AD4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Analog-Digital converter module NZ2GN2B-60AD4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Digital-Analog converter module NZ2GN2S-60DA4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Digital-Analog converter module NZ2GN2B-60DA4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN compatible coupler NZ2FT-GN vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric FPGA module NZ2GN2S-D41P01 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric FPGA module NZ2GN2S-D41D01 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric FPGA module NZ2GN2S-D41PD02 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Tension meter LM7-1LG vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Tension meter LM7-2LG vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5W-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-HS vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-RJ vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-LL vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5D-G4 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-J5 MR-MD333G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G4-HS vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-4G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-PG vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG-S vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A800-GN vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-E vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-SCE vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN expansion unit FCU8-EX569 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3715-FHCBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3712-WXCBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3715-XRBA vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3715-XRBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3712-XRBA vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3712-XRBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3710-XRBA vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3710-XRBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3708-XRBA vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric GOT3000 Series GT3708-XRBD vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Communication Unit GT25-J71GN13-T2 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion Control Software SWM-G vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Motion Control Software SWM-G-N1 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-60 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-300 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-90 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-720 vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK1S-M vers:all/* (CVE-2026-13584)</li>\n<li>Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK2S-M vers:all/* (CVE-2026-13584)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.1</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)</td>\n<td>Improper Enforcement of Message Integrity During Transmission in a Communication Channel</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13584</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CWE-924) vulnerability exists in the CC-Link IE TSN communication protocol. This vulnerability could allow an attacker with access to the same network segment to tamper with communication data, such as control input and output values, by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13584\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-16: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-64: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-128: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-256: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-P32: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-T2: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-SX: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-EIP: vers:all/*, Mitsubishi Electric Master/local module FX5-CCLGN-MS: vers:all/*, Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-SX: vers:all/*, Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-T2: vers:all/*, Mitsubishi Electric Motion module RD78G4: vers:all/*, Mitsubishi Electric Motion module RD78G8: vers:all/*, Mitsubishi Electric Motion module RD78G16: vers:all/*, Mitsubishi Electric Motion module RD78G64: vers:all/*, Mitsubishi Electric Motion module RD78GHV: vers:all/*, Mitsubishi Electric Motion module RD78GHW: vers:all/*, Mitsubishi Electric Motion module FX5-40SSC-G: vers:all/*, Mitsubishi Electric Motion module FX5-80SSC-G: vers:all/*, Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G4: vers:all/*, Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G16: vers:all/*, Mitsubishi Electric Motion Control Board MR-EM441G: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCF1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCF1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCE3-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCE3-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A4-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A4-16DE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A2-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A2-16TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A42-16DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A42-16DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16TE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-14DT: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-16DTE: vers:all/*, Mitsubishi Electric Analog-Digital converter module NZ2GN2S-60AD4: vers:all/*, Mitsubishi Electric Analog-Digital converter module NZ2GN2B-60AD4: vers:all/*, Mitsubishi Electric Digital-Analog converter module NZ2GN2S-60DA4: vers:all/*, Mitsubishi Electric Digital-Analog converter module NZ2GN2B-60DA4: vers:all/*, Mitsubishi Electric CC-Link IE TSN compatible coupler NZ2FT-GN: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41P01: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41D01: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41PD02: vers:all/*, Mitsubishi Electric Tension meter LM7-1LG: vers:all/*, Mitsubishi Electric Tension meter LM7-2LG: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5W-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-HS: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-RJ: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-LL: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5D-G4 : vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-MD333G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G4-HS: vers:all/*, Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-4G: vers:all/*, Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-PG: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG-S: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A800-GN: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-E: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-SCE: vers:all/*, Mitsubishi Electric Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN: vers:all/*, Mitsubishi Electric CC-Link IE TSN expansion unit FCU8-EX569: vers:all/*, Mitsubishi Electric CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB: vers:all/*, Mitsubishi Electric CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL: vers:all/*, Mitsubishi Electric Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-FHCBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-WXCBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3710-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3710-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3708-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3708-XRBD: vers:all/*, Mitsubishi Electric CC-Link IE TSN Communication Unit GT25-J71GN13-T2: vers:all/*, Mitsubishi Electric Motion Control Software SWM-G: vers:all/*, Mitsubishi Electric Motion Control Software SWM-G-N1: vers:all/*, Mitsubishi Electric CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M: vers:all/*, Mitsubishi Electric Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M: vers:all/*, Mitsubishi Electric Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-60: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-300: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-90: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-720: vers:all/*, Mitsubishi Electric CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M: vers:all/*, Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK1S-M: vers:all/*, Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK2S-M: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>No fix planned</strong><br>For customers using the affected products, please refer to Mitsubishi Electric's security advisory, \"<a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf</a>\" and take the measures described there.<br>&nbsp;</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends restricting physical access to the affected products and the CC-Link IE TSN network to which the affected products are connected by taking measures such as the following: (a) managing access to and from the site where the affected products are installed, (b) locking the control panel in which the affected products and/or the network devices are installed, and (c) locking the Ethernet ports such as with port lock accessories, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends using the affected products within a trusted network where communication with untrusted networks and hosts is blocked by a firewall or similar measures, to minimize the risk of exploitation of this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends appropriately configuring credentials and access privileges for network devices installed at the boundary between trusted networks and external networks, to minimize the risk of exploitation of this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/924.html\">CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Alessandro Di Pinto, Giovanni Dini Gentilini, Luca Cremona, Gabriele Quagliarella of Nozomi Networks, Inc. reported this vulnerability to Mitsubishi Electric.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric <a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf\">2026-005</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-30</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-30</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-07-30</td>\n<td>2</td>\n<td>CISA Republication - Initial CISA Republication of Mitsubishi Electric 2026-005 advisory</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>3</td>\n<td>MXF100S-N32, MXF100S-P32, MXF100S-8-N32, MXF100S-8-P32, MXF100S-16-N32, MXF100S-16-P32, LD78G4, and LD78G16 have been added as affected products and MI2532-W, MI2332-W, and NZ2GACP610-60 have been removed from affected products.</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>4</td>\n<td>CISA Republication update based on Mitsubishi Electric 2026-005 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-07",
        "title": "Schneider Electric PowerChute Serial Shutdown",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data.</strong></p>\n<p>The following versions of Schneider Electric PowerChute Serial Shutdown are affected:</p>\n<ul>\n<li>PowerChute Serial Shutdown vers:intdot/&lt;=1.5, 1.6 (CVE-2026-13348)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 5.3</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric PowerChute Serial Shutdown</td>\n<td>Improper Restriction of Excessive Authentication Attempts</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Energy, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13348</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13348\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric PowerChute Serial Shutdown</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>PowerChute Serial Shutdown Version 1.5 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available for download here: \u2022 Windows: <a href=\"https://www.se.com/ww/en/download/document/spd-pcss_win_en/\">https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/</a> Reboot needed: Upon installation, the service is automatically restarted. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Specific instructions and hardening guidelines for these remediations can be found in the <a href=\"https://www.se.com/ww/en/download/document/spd-pcss_win_en/\">Security Handbook</a>.<br>&nbsp;</p>\n<p><strong>Vendor fix</strong><br>Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available for download here: \u2022 Linux: <a href=\"https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/\">https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/</a> Reboot needed: Upon installation, the service is automatically restarted. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Specific instructions and hardening guidelines for these remediations can be found in the <a href=\"https://www.se.com/ww/en/download/document/spd-pcss_win_en/\">Security Handbook</a>.</p>\n<p>For more information see the associated Schneider Electric security advisory <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-223-01.json\">Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown - SEVD-2026-223-01 CSAF Version</a>, <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-01&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-223-01.pdf\">Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown - SEVD-2026-223-01 PDF Version</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/307.html\">CWE-307 Improper Restriction of Excessive Authentication Attempts</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices.&nbsp;</p>\n<ul>\n<li>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.&nbsp;</li>\n<li>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.&nbsp;</li>\n<li>Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.&nbsp;</li>\n<li>Never connect programming software to any network other than the network intended for that device.&nbsp;</li>\n<li>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.&nbsp;</li>\n<li>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.&nbsp;</li>\n<li>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.&nbsp;</li>\n<li>When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.&nbsp;</li>\n</ul>\n<p>For more information refer to the <a href=\"https://www.se.com/us/en/download/document/7EN52-0390/%20\">Schneider Electric Recommended Cybersecurity Best Practices document</a>.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: <a href=\"https://www.se.com/ww/en/work/solutions/cybersecurity/\">https://www.se.com/ww/en/work/solutions/cybersecurity/</a>. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: <a href=\"https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp\">https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</a></p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT <a href=\"https://download.schneider-electric.com/files?p_doc_ref=sevd-2026-223-01&amp;p_endoctype=security+and+safety+notice&amp;p_file_name=sevd-2026-223-01.pdf\">SEVD-2026-223-01</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-11</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-223-01 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-02",
        "title": "Mitsubishi Electric GX Works3 and Motion Control Settings",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs.</strong></p>\n<p>The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected:</p>\n<ul>\n<li>Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688)</li>\n<li>Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3) vers:all/* (CVE-2026-15688)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>Mitsubishi Electric</td>\n<td>Mitsubishi Electric GX Works3 and Motion Control Settings</td>\n<td>Incorrect Implementation of Authentication Algorithm</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Japan</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-15688</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Incorrect Implementation of Authentication Algorithm (CWE-303) vulnerability in the affected products allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-15688\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Mitsubishi Electric GX Works3 and Motion Control Settings</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Mitsubishi Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mitsubishi Electric GX Works3: vers:all/*, Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3): vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Workaround</strong><br>For customers using GX Works3, please download version 1.096A or later from the link <a href=\"https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&amp;kisyu=/plceng&amp;shiryoid=1000001411&amp;lang=2&amp;select=0&amp;softid=1&amp;infostatus=1_2_1&amp;viewradio=0&amp;viewstatus=&amp;viewpos=\">https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&amp;kisyu=/plceng&amp;shiryoid=1000001411&amp;lang=2&amp;select=0&amp;softid=1&amp;infostatus=1_2_1&amp;viewradio=0&amp;viewstatus=&amp;viewpos=</a>, install it, and set the security version for projects to \"2\". Please refer to \u201c15.9 Preventing Illegal Access to/Falsification of Data (Security Version)\u201d in \u201cGX Works3 Operating Manual\u201d for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory available at \"<a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf</a>\".<br>&nbsp;</p>\n<p><strong>Workaround</strong><br>For customers using Motion Control Settings (Software packaged with GX Works3), Please download version 1.070Y or later from the link \"<a href=\"https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&amp;kisyu=/ssc&amp;shiryoid=1000000803&amp;lang=2&amp;select=0&amp;softid=1&amp;infostatus=1_8_1&amp;viewradio=0&amp;viewstatus=&amp;viewpos=\">https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&amp;kisyu=/ssc&amp;shiryoid=1000000803&amp;lang=2&amp;select=0&amp;softid=1&amp;infostatus=1_8_1&amp;viewradio=0&amp;viewstatus=&amp;viewpos=</a>\", install it, and set the security version for projects to \"2\". Please refer to \u201c12.5 Preventing Illegal Access to/Falsification of Data (Security Version)\u201d in \u201cMotion Control Setting Function Help\u201d for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory at \"<a href=\"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf\">https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf</a>\".<br>&nbsp;</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends using a computer with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc., to prevent unauthorized access, and allowing remote login only to trusted users when connecting a computer with the affected product to the Internet, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends preventing the user from clicking on web links contained in emails or other messages from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends installing antivirus software on a computer running the affected product, to minimize the risk of exploiting this vulnerability.</p>\n<p><strong>Mitigation</strong><br>For customers of the affected products, Mitsubishi Electric recommends restricting physical access to a computer on which the affected product is installed, as well as to computers and network devices that can communicate with it, to minimize the risk of exploiting this vulnerability.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/303.html\">CWE-303 Incorrect Implementation of Authentication Algorithm</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.2</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Mayeul Fargier, Erwan Cordier, No\u00e9 Flatreaud reported this vulnerability to Mitsubishi Electric.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Mitsubishi Electric 2026-007 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-17</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-17</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Mitsubishi Electric 2026-007 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-03",
        "title": "Hitachi Energy FACTS Control Platform (FCP)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. \u2022 SVC Light (STATCOM) \u2022 Fixed Series Capacitor \u2022 Thyristor Controlled Series Capacitor \u2022 Static Var Compensator \u2022 Static Watt Compensator \u2022 Hybrid Synchronous Condensers Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The affected FCP versions are only applicable if GWS component is present.</strong></p>\n<p>The following versions of Hitachi Energy FACTS Control Platform (FCP) are affected:</p>\n<ul>\n<li>FACTS Control Platform (FCP) 3.4.0, 3.7.0, 3.8.0, 3.10.0, 3.12.0, 3.14.0, 3.15.0, 4.0.0, 4.0.1, 4.1.0, 4.1.1 (CVE-2024-4872, CVE-2024-3980, CVE-2024-3982, CVE-2024-7940, CVE-2024-7941)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.9</td>\n<td>Hitachi Energy</td>\n<td>Hitachi Energy FACTS Control Platform (FCP)</td>\n<td>Improper Neutralization of Special Elements in Data Query Logic, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Authentication Bypass by Capture-replay, Missing Authentication for Critical Function, URL Redirection to Untrusted Site ('Open Redirect')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Switzerland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-4872</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in the query validation of the FACTS Control system with GWS component. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-4872\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FACTS Control Platform (FCP)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Follow general mitigation factors.</p>\n<p>For more information see the associated Hitachi Energy security advisory <a href=\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000229&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch\">8DBD000229</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/943.html\">CWE-943 Improper Neutralization of Special Elements in Data Query Logic</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-3980</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The FACTS Control system with GWS allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-3980\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FACTS Control Platform (FCP)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Follow general mitigation factors.</p>\n<p>For more information see the associated Hitachi Energy security advisory <a href=\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000229&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch\">8DBD000229</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/22.html\">CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-3982</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An attacker with local access to machine where FACTS Control system with GWS is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. Note: By default, the session logging level is not enabled and only users with administrator rights can enable it.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-3982\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FACTS Control Platform (FCP)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Follow general mitigation factors.</p>\n<p>For more information see the associated Hitachi Energy security advisory <a href=\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000229&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch\">8DBD000229</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/294.html\">CWE-294 Authentication Bypass by Capture-replay</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-7940</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The FACTS Control system with GWS product exposes a service that is intended for local only to all network interfaces without any authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-7940\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FACTS Control Platform (FCP)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Follow general mitigation factors.</p>\n<p>For more information see the associated Hitachi Energy security advisory <a href=\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000229&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch\">8DBD000229</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-7941</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A vulnerability exists in FACTS Control system with GWS where a HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-7941\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Hitachi Energy FACTS Control Platform (FCP)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Hitachi Energy</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Follow general mitigation factors.</p>\n<p>For more information see the associated Hitachi Energy security advisory <a href=\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000229&amp;LanguageCode=en&amp;DocumentPartId=&amp;Action=launch\">8DBD000229</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/601.html\">CWE-601 URL Redirection to Untrusted Site ('Open Redirect')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Hitachi Energy reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Notice</h2>\n<p>The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.</p>\n<hr>\n<h2>Support</h2>\n<p>For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see <a href=\"https://www.hitachienergy.com/contact-us/\">https://www.hitachienergy.com/contact-us/</a> for Hitachi Energy contact-centers.</p>\n<hr>\n<h2>General Mitigation Factors</h2>\n<p>Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Additional information on Industrial Control Systems Cybersecurity Best Practices can be found in the Hitachi Energy \u201cIndustrial Control Systems Cybersecurity Best Practices\u201d Cybersecurity Notification. [1]</p>\n<hr>\n<h2>SSVC</h2>\n<p>SSVCv2/E:N/A:N/2026-07-24T09:43:32Z/</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Hitachi Energy PSIRT <a href=\"https://publisher.hitachienergy.com/preview?documentid=8dbd000229&amp;languagecode=en&amp;documentpartid=&amp;action=launch\">8DBD000229 </a>from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-28</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-28</td>\n<td>1</td>\n<td>Initial public release</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Hitachi Energy PSIRT 8DBD000229 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-05",
        "title": "Schneider Electric NetBotz 5 750/755",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 \u2013 750/755 products.The NetBotz 5 \u2013 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access.</strong></p>\n<p>The following versions of Schneider Electric NetBotz 5 750/755 are affected:</p>\n<ul>\n<li>NetBotz 5 750 vers:intdot/&lt;=5.5.2 (CVE-2026-13336, CVE-2026-13337)</li>\n<li>NetBotz 5 755 vers:intdot/&lt;=5.5.2 (CVE-2026-13336, CVE-2026-13337)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.4</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric NetBotz 5 750/755</td>\n<td>Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), SQL Injection: Hibernate</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Critical Manufacturing, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13336</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux Operating system commands when a system back up is restored that has been maliciously modified.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13336\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric NetBotz 5 750/755</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>NetBotz 5 750 versions 5.5.2 and prior, NetBotz 5 755 Versions 5.5.2 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 5.6.0 of NetBotz 5 750/755 includes a fix for these vulnerabilities and is available for download here: <a href=\"https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware\">https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware</a> Reboot needed: Upon install, the offer will automatically restart. A customer can validate a successful install by logging into the GUI and selecting the \u2018About NetBotz\u2019 option. This will indicate the <a href=\"https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware\">installed version.</a><br>&nbsp;</p>\n<p>For more information see the associated Schneider Electric security advisory <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-223-02.json\">Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 CSAF Version</a>, <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-223-02.pdf\">Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 PDF Version</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/78.html\">CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-13337</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-564:SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the NetBotz via the web-service interface or web-ui.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-13337\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric NetBotz 5 750/755</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>NetBotz 5 750 versions 5.5.2 and prior, NetBotz 5 755 Versions 5.5.2 and prior</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 5.6.0 of NetBotz 5 750/755 includes a fix for these vulnerabilities and is available for download here: <a href=\"https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware\">https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware</a> Reboot needed: Upon install, the offer will automatically restart. A customer can validate a successful install by logging into the GUI and selecting the \u2018About NetBotz\u2019 option. This will indicate the <a href=\"https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware\"><u>installed version.</u></a><br>&nbsp;</p>\n<p>For more information see the associated Schneider Electric security advisory <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-223-02.json\">Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 CSAF Version</a>, <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-223-02&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-223-02.pdf\">Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 PDF Version</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/564.html\">CWE-564 SQL Injection: Hibernate</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.6</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices.&nbsp;</p>\n<ul>\n<li>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.&nbsp;</li>\n<li>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.&nbsp;</li>\n<li>Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.&nbsp;</li>\n<li>Never connect programming software to any network other than the network intended for that device.&nbsp;</li>\n<li>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.&nbsp;</li>\n<li>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.&nbsp;</li>\n<li>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.&nbsp;</li>\n<li>* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.&nbsp;</li>\n</ul>\n<p>For more information refer to the <a href=\"https://www.se.com/us/en/download/document/7EN52-0390/%20\">Schneider Electric Recommended Cybersecurity Best Practices document</a>.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: <a href=\"https://www.se.com/ww/en/work/solutions/cybersecurity/\">https://www.se.com/ww/en/work/solutions/cybersecurity/</a>. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: <a href=\"https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp\">https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</a></p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT <a href=\"https://download.schneider-electric.com/files?p_doc_ref=sevd-2026-223-02&amp;p_endoctype=security+and+safety+notice&amp;p_file_name=sevd-2026-223-02.pdf\">SEVD-2026-223-02</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-08-11</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-08-11</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-223-02 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-04",
        "title": "Schneider Electric Modicon M340 Controller and Communication Modules",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its Modicon M340</strong><a href=\"https://www.cisa.gov//www.se.com/ww/en/product-range/1468-modicon-m340-pac/\"><strong> https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/</strong></a><strong>, BMXNOR0200H </strong><a href=\"https://www.se.com/us/en/product/bmxnor0200h/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/\"><strong>https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/</strong></a><strong>: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 </strong><a href=\"https://www.se.com/us/en/product/bmxngd0100/communication-module-modicon-m580-global-data-service/\"><strong>https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/</strong></a><strong>: M580 Global Data module, BMXNOC0401 </strong><a href=\"https://www.se.com/us/en/product/bmxnoc0401/network-module-modicon-m340-ethernet-ip-and-modbus-tcp-4-x-rj45/?pagetype=product&amp;sourceid=bmxnoc0401\"><strong>https://www.se.com/us/en/product/BMXNOC0401/network-module-modicon-m340-ethernet-ip-and-modbus-tcp-4-x-rj45/?pageType=product&amp;sourceId=BMXNOC0401</strong></a><strong>: Modicon M340 X80 Ethernet Communication modules, BMXNOE0100 </strong><a href=\"https://www.se.com/ww/en/product/bmxnoe0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/?pagetype=product&amp;sourceid=bmxnoe0100\"><strong>https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/?pageType=product&amp;sourceId=BMXNOE0100</strong></a><strong>: Modbus/TCP Ethernet Modicon M340 module, BMXNOE0110 </strong><a href=\"https://www.se.com/ww/en/product/bmxnoe0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/\"><strong>https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/</strong></a><strong>: Modbus/TCP Ethernet Modicon M340 FactoryCast module product(s). Failure to apply the fix provided below may risk Denial Of Service attack, which could result in the unavailability of the devices.</strong></p>\n<p>The following versions of Schneider Electric Modicon M340 Controller and Communication Modules are affected:</p>\n<ul>\n<li>Schneider Electric Ethernet/Serial RTU Module: vers:generic/&lt;SV1.7_IR27</li>\n<li>Schneider Electric M580 Global Data module: vers:all/*</li>\n<li>Schneider Electric Ethernet / Serial RTU Module: vers:all/*</li>\n<li>Schneider Electric Modbus/TCP Ethernet Modicon M340 module: vers:intdot/&lt;3.60</li>\n<li>Schneider Electric Modbus/TCP Ethernet Modicon M340 FactoryCast module: vers:intdot/&lt;6.80</li>\n<li>Schneider Electric Modicon M340 Firmware Versions prior to SV3.70 installed on Modicon M340 Controller: All versions</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric Modicon M340 Controller and Communication Modules</td>\n<td>Improper Input Validation</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Chemical, Commercial Facilities, Critical Manufacturing, Energy, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2025-6625</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2025-6625\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric Modicon M340 Controller and Communication Modules</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Ethernet / Serial RTU Module All versions, M580 Global Data module All versions, Modicon M340 X80 Ethernet Communication modules All versions, Modbus/TCP Ethernet Modicon M340 module Versions prior to 3.60, Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to 6.80</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>fixed, known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Version 3.60 of BMXNOE0100 includes a fix for this vulnerability and is available for download here: <a href=\"https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/\">https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/</a>&nbsp;</p>\n<p>Reboot is needed to complete the firmware upgrade<br>&nbsp;</p>\n<p><strong>Vendor fix</strong><br>Version 6.80 of BMXNOE0110 includes a fix for this vulnerability and is available for download here: <a href=\"https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/\">https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/</a>&nbsp;</p>\n<p>Reboot is needed to complete the firmware upgrade<br>&nbsp;</p>\n<p><strong>Vendor fix</strong><br>Version SV3.70 of Modicon M340 includes a fix for this vulnerability and is available for download here:&nbsp;<br><a href=\"https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware\">https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware</a></p>\n<p><strong>Vendor fix</strong><br>Version SV1.7 IR27 of BMXNOR0200H includes a fix for this vulnerability and is available for download here:&nbsp;<br><a href=\"https://www.se.com/ww/en/product/BMXNOR0200H/ethernet-serial-rtu-module-2-x-rj45/\">https://www.se.com/ww/en/product/BMXNOR0200H/ethernet-serial-rtu-module-2-x-rj45/</a></p>\n<p><strong>Mitigation</strong><br>If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:&nbsp;</p>\n<ul>\n<li>FTP service is disabled by default.</li>\n<li>Ensure to disable FTP service when not in use.</li>\n<li>Setup network segmentation and implement a firewall to block all unauthorized access to ports 21/FTP.</li>\n<li>Use VPN (Virtual Private Networks) tunnels if remote access is required.</li>\n</ul>\n<p><strong>Mitigation</strong><br>Schneider Electric is establishing a remediation plan for all future versions of:</p>\n<ul>\n<li>Modicon M340</li>\n<li>BMXNOR0200H</li>\n<li>BMXNGD0100</li>\n<li>\n<p>BMXNOC401&nbsp;</p>\n<p>Schneider Electric will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:&nbsp;</p>\n</li>\n<li>FTP service is disabled by default.</li>\n<li>Ensure to disable FTP service when not in use.</li>\n<li>Setup network segmentation and implement a firewall to block all unauthorized access to ports 21/FTP.</li>\n<li>Use VPN (Virtual Private Networks) tunnels if remote access is required.</li>\n</ul>\n</div>\n<p><strong>Mitigation</strong></p>\n<p>For more information see the associated Schneider Electric security advisory <a href=\"https://download.schneider-electric.com/files?p_doc_ref=sevd-2025-224-05&amp;p_endoctype=security+and+safety+notice&amp;p_file_name=sevd-2025-224-05.json\">Modicon M340 Controller and Communication Modules - SEVD-2025-224-05 CSAF Version</a>, <a href=\"https://download.schneider-electric.com/files?p_doc_ref=sevd-2025-224-05&amp;p_endoctype=security+and+safety+notice&amp;p_file_name=sevd-2025-224-05.pdf\">Modicon M340 Controller and Communication Modules - SEVD-2025-224-05 PDF Version</a>.</p>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Schneider Electric CPCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>We strongly recommend the following industry cybersecurity best practices.&nbsp;</p>\n<ul>\n<li>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.&nbsp;</li>\n<li>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.&nbsp;</li>\n<li>Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.&nbsp;</li>\n<li>Never connect programming software to any network other than the network intended for that device.&nbsp;</li>\n<li>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.&nbsp;</li>\n<li>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.&nbsp;</li>\n<li>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.&nbsp;</li>\n<li>When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). &nbsp;Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.&nbsp;</li>\n</ul>\n<p>For more information refer to the <a href=\"https://www.se.com/us/en/download/document/7en52-0390/\">Schneider Electric Recommended Cybersecurity Best Practices</a> document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: <a href=\"https://www.se.com/ww/en/work/solutions/cybersecurity/\">https://www.se.com/ww/en/work/solutions/cybersecurity/</a>. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: <a href=\"https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp\">https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp</a></p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT <a href=\"https://download.schneider-electric.com/files?p_doc_ref=sevd-2025-224-05&amp;p_endoctype=security+and+safety+notice&amp;p_file_name=sevd-2025-224-05.pdf\">SEVD-2025-224-05</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2025-08-12</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2025-08-12</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-04-14</td>\n<td>2</td>\n<td>Remediation is available for Modicon M340</td>\n</tr>\n<tr>\n<td>2026-08-11</td>\n<td>3</td>\n<td>Remediation is available for BMXNOR0200H.</td>\n</tr>\n<tr>\n<td>2026-09-17</td>\n<td>4</td>\n<td>Initial CISA Republication of Schneider Electric CPCERT SEVD-2025-224-05 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-01",
        "title": "Bransys ELD",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-260-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow unauthorized access to telemetry data and firmware.</strong></p>\n<p>The following versions of Bransys ELD are affected:</p>\n<ul>\n<li>Android &lt;11.00.00 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960)</li>\n<li>iOS &lt;1.1.54 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>Bransys</td>\n<td>Bransys ELD</td>\n<td>Use of Hard-coded Credentials, Cleartext Transmission of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>United States</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-86520</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is shipped with hardcoded MQTT credentials, which will grant read access to real-time data for every active device across a subset of carriers that were connected to the affected MQTT broker.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-86520\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Bransys ELD</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Bransys</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Bransys Android: &lt;11.00.00, Bransys iOS: &lt;1.1.54</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-86689</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product is susceptible to cleartext transmission of sensitive information, which could allow an attacker to connect to the broker and read all data.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-86689\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Bransys ELD</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Bransys</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Bransys Android: &lt;11.00.00, Bransys iOS: &lt;1.1.54</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/319.html\">CWE-319 Cleartext Transmission of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-77960</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected product ships with hardcoded FTP credentials which could allow an attacker to connect to the server and read data.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-77960\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Bransys ELD</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Bransys</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Bransys Android: &lt;11.00.00, Bransys iOS: &lt;1.1.54</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Jaime Lightfoot reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<ul>\n<li>Do not click web links or open attachments in unsolicited email messages.</li>\n<li>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</li>\n<li>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</li>\n</ul>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-17</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-17</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 17 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 17 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/using-cyber-decoys-strengthen-detection-and-response",
        "title": "Using Cyber Decoys to Strengthen Detection and Response",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/using-cyber-decoys-strengthen-detection-and-response",
        "summary": "<div class=\"OutlineElement Ltr SCXW53093809 BCX8\">\n<p>CISA developed this guidance to help defensive teams at varying levels of cybersecurity maturity plan and implement cyber decoy strategies that strengthen their detection and response capabilities. Many organizations struggle to detect adversaries who use legitimate credentials, native tools, and <a class=\"Hyperlink SCXW53093809 BCX8\" href=\"https://www.cisa.gov/resources-tools/resources/identifying-and-mitigating-living-land-techniques\" target=\"_blank\" rel=\"noreferrer noopener\"><u>living off the land</u></a> (LOTL) techniques to conduct discovery, move laterally, and access data. Cyber decoys are assets that appear to be legitimate systems, accounts, or data, but are designed to distract adversaries, detect their presence, or facilitate collection of cyber threat intelligence (CTI). As organizations adopt <a class=\"Hyperlink SCXW53093809 BCX8\" href=\"https://www.cisa.gov/topics/cybersecurity-best-practices/zero-trust\" target=\"_blank\" rel=\"noreferrer noopener\"><u>Zero Trust</u></a> models, they should assume that a malicious threat actor may gain some level of access to their environment and plan accordingly.&nbsp;&nbsp;</p>\n</div>\n<div class=\"OutlineElement Ltr SCXW53093809 BCX8\">\n<p>&nbsp;Cyber decoys complement Zero Trust by:&nbsp;&nbsp;</p>\n</div>\n<div class=\"ListContainerWrapper SCXW53093809 BCX8\">\n<ul type=\"disc\">\n<li>Supporting continuous monitoring and verification,&nbsp;&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW53093809 BCX8\">\n<ul type=\"disc\">\n<li>Creating high-fidelity alerts for suspicious activity,&nbsp;&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW53093809 BCX8\">\n<ul type=\"disc\">\n<li>Reducing alert fatigue, and&nbsp;&nbsp;</li>\n</ul>\n</div>\n<div class=\"ListContainerWrapper SCXW53093809 BCX8\">\n<ul type=\"disc\">\n<li>Helping defenders detect post-compromise activity, including adversary LOTL techniques.&nbsp;</li>\n</ul>\n<p>This guidance introduces decoy concepts\u2014including tripwires, breadcrumbs, and honeytokens\u2014and uses the <a class=\"Hyperlink SCXW53093809 BCX8\" href=\"https://engage.mitre.org/starter-kit/\" target=\"_blank\" rel=\"noreferrer noopener\"><u>MITRE Engage\u2122</u></a> and <a class=\"Hyperlink SCXW53093809 BCX8\" href=\"https://attack.mitre.org/resources/\" target=\"_blank\" rel=\"noreferrer noopener\"><u>MITRE ATT&amp;CK\u00ae</u></a> frameworks to provide practical, low-complexity steps for planning, implementing, and refining decoy operations. For additional information, visit <a class=\"Hyperlink SCXW53093809 BCX8\" href=\"https://www.cisa.gov/news-events/news/best-practices-mitre-attckr-mapping\" target=\"_blank\" rel=\"noreferrer noopener\"><u>CISA\u2019s Best Practices for MITRE ATT&amp;CK Mapping</u></a>.&nbsp;</p>\n</div>",
        "summary_is_html": true,
        "first_seen": "Wed, 16 Sep 26 12:00:00 +0000",
        "last_updated": "Wed, 16 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/16/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/16/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76460\" target=\"_blank\">CVE-2026-76460</a> Cisco Identity Services Engine Incorrect Use of Privileged APIs Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-87886\" target=\"_blank\">CVE-2026-87886</a> Acronis Backup Incorrect Default Permissions Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.&nbsp;</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.&nbsp;</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.&nbsp;</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 16 Sep 26 12:00:00 +0000",
        "last_updated": "Wed, 16 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/16/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-58704\" target=\"_blank\" title=\"https://www.cve.org/cverecord?id=cve-2026-58704\">CVE-2026-58704</a> Google Pixel Improper Authorization Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>",
        "summary_is_html": true,
        "first_seen": "Wed, 16 Sep 26 12:00:00 +0000",
        "last_updated": "Wed, 16 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-05",
        "title": "Siemens Reyrolle 7SR5",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-05",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-05.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens Reyrolle 7SR5 are affected:</p>\n<ul>\n<li>Reyrolle 7SR5 vers:intdot/&lt;2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653, CVE-2026-62654)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>Siemens</td>\n<td>Siemens Reyrolle 7SR5</td>\n<td>Integer Overflow or Wraparound, Improper Neutralization of Delimiters, Use of Out-of-range Pointer Offset, Missing Authentication for Critical Function, Insufficient Entropy, Improper Input Validation, Out-of-bounds Write, Allocation of Resources Without Limits or Throttling, Authentication Bypass Using an Alternate Path or Channel, Insertion of Sensitive Information Into Debugging Code, Download of Code Without Integrity Check</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-42384</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Integer Overflow or Wraparound vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and produce a segmentation fault on the application.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-42384\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-42385</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Neutralization of Delimiters vulnerability in Cesanta Mongoose Web Server v7.14 allows to trigger an out-of-bound memory write if the PEM certificate contains unexpected characters.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-42385\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/140.html\">CWE-140 Improper Neutralization of Delimiters</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-42386</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Use of Out-of-range Pointer Offset vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and produce a segmentation fault on the application.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-42386\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/823.html\">CWE-823 Use of Out-of-range Pointer Offset</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-42391</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Use of Out-of-range Pointer Offset vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and force the application to read unintended heap memory space.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-42391\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/823.html\">CWE-823 Use of Out-of-range Pointer Offset</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2024-42392</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Improper Neutralization of Delimiters vulnerability in Cesanta Mongoose Web Server v7.14 allows to trigger an infinite loop bug if the input string contains unexpected characters.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2024-42392\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/140.html\">CWE-140 Improper Neutralization of Delimiters</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62645</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62645\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62646</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62646\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/331.html\">CWE-331 Insufficient Entropy</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62647</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62647\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/20.html\">CWE-20 Improper Input Validation</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62648</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62648\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62649</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62649\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/770.html\">CWE-770 Allocation of Resources Without Limits or Throttling</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62650</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62650\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/288.html\">CWE-288 Authentication Bypass Using an Alternate Path or Channel</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62652</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62652\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/215.html\">CWE-215 Insertion of Sensitive Information Into Debugging Code</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62653</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62653\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/787.html\">CWE-787 Out-of-bounds Write</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-62654</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-62654\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Reyrolle 7SR5</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Reyrolle 7SR5 &lt; V2.70</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2.70 or later version<br><a href=\"https://support.industry.siemens.com/cs/ww/en/view/109772413/\">https://support.industry.siemens.com/cs/ww/en/view/109772413/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/494.html\">CWE-494 Download of Code Without Integrity Check</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends protecting network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: <a href=\"https://www.siemens.com/gridsecurity\">https://www.siemens.com/gridsecurity</a></p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: <a href=\"https://www.siemens.com/cert/advisories\">https://www.siemens.com/cert/advisories</a></p>\n<p>Additional information on industrial security by Siemens can be found on the <a href=\"https://www.siemens.com/industrialsecurity\">Siemens industrial security webpage</a></p>\n<p>For more information see the associated Siemens security advisory SSA-142885 in <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-142885.html\">HTML</a> and <a href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-142885.json\">CSAF</a>.</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: <a href=\"https://www.siemens.com/productcert/terms-of-use\">https://www.siemens.com/productcert/terms-of-use</a>.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-142885.html\">SSA-142885</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-08</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-08</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-09-15</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-142885 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-03",
        "title": "mySCADA myPRO Manager",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-03",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-03.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem.</strong></p>\n<p>The following versions of mySCADA myPRO Manager are affected:</p>\n<ul>\n<li>mySCADA myPRO Manager &lt;=2.1 (CVE-2026-73807, CVE-2026-82567)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.8</td>\n<td>mySCADA Technologies</td>\n<td>mySCADA myPRO Manager</td>\n<td>Missing Authorization, Missing Authentication for Critical Function</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Czechia</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-73807</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The mySCADA myPRO Manager command API does not properly enforce authentication for privileged functions. An unauthenticated attacker with network access to the affected API could exploit this vulnerability to access privileged management functions.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-73807\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>mySCADA myPRO Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>mySCADA Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>mySCADA Technologies mySCADA myPRO Manager: &lt;=2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>mySCADA Technologies has addressed these issues in Version 2.2 and recommends that users update to the latest version. Users are notified in mySCADA Pro Manager about the availability of a new version if the device is connected to the internet. Otherwise, users can download the mySCADA Pro Manager from the webpage.<br><a href=\"https://www.myscada.org/downloads/mySCADAPROManager/\">https://www.myscada.org/downloads/mySCADAPROManager/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.8</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-82567</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The myPRO Manager notification gateway exposes an unauthenticated HTTP endpoint used to send SMS messages through a connected GSM modem. The endpoint is accessible over the network and does not require authentication before accepting a phone number and message from a request and sending the specified SMS message. An unauthenticated attacker with network access to the notification gateway could exploit this vulnerability to send arbitrary SMS messages through the connected modem.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82567\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>mySCADA myPRO Manager</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>mySCADA Technologies</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>mySCADA Technologies mySCADA myPRO Manager: &lt;=2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>mySCADA Technologies has addressed these issues in Version 2.2 and recommends that users update to the latest version. Users are notified in mySCADA Pro Manager about the availability of a new version if the device is connected to the internet. Otherwise, users can download the mySCADA Pro Manager from the webpage.<br><a href=\"https://www.myscada.org/downloads/mySCADAPROManager/\">https://www.myscada.org/downloads/mySCADAPROManager/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Shirshak Secnora O\u00dc reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.&nbsp;</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.&nbsp;</li>\n<li>Locate control system networks and remote devices behind firewalls and isolating them from business networks.&nbsp;</li>\n<li>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:&nbsp;</p>\n<ul>\n<li>Do not click web links or open attachments in unsolicited email messages.&nbsp;</li>\n<li>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.&nbsp;</li>\n<li>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</li>\n</ul>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-15</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-15</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08",
        "title": "CareCam CM2507",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recover stored credentials.</strong></p>\n<p>The following versions of CareCam CM2507 are affected:</p>\n<ul>\n<li>HMT.CM2507 Firmware v251211.1507 (CVE-2026-88259, CVE-2026-84398, CVE-2026-84400, CVE-2026-81305, CVE-2026-85478, CVE-2026-85497, CVE-2026-81321)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 7.5</td>\n<td>CareCam</td>\n<td>CareCam CM2507</td>\n<td>Missing Authentication for Critical Function, Empty Password in Configuration File, Inclusion of Functionality from Untrusted Control Sphere, Use of Password Hash With Insufficient Computational Effort, Cleartext Storage of Sensitive Information</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>China</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-88259</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-88259\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-84398</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CM2507 IP cameras accept an empty password for a privileged account exposed through its ONVIF management service. An attacker with network access to the affected device could access privileged management functions and obtain device, user, media-profile, and stream configuration information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-84398\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/258.html\">CWE-258 Empty Password in Configuration File</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-84400</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-84400\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.1</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>2.3</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81305</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81305\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/829.html\">CWE-829 Inclusion of Functionality from Untrusted Control Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-85478</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access functionality that permits inspection or modification of boot configuration, firmware data, and software loaded by the device.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-85478\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>3.5</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\">CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>2.4</td>\n<td>LOW</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-85497</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-85497\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/916.html\">CWE-916 Use of Password Hash With Insufficient Computational Effort</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81321</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>CM2507 IP cameras store configured wireless network credentials in cleartext within the device filesystem. An attacker who obtains filesystem access through physical access, a debugging interface, or another vulnerability could recover the configured network identifier and pre-shared key.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81321\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>CareCam CM2507</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>CareCam</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>CareCam HMT.CM2507 Firmware: v251211.1507</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/312.html\">CWE-312 Cleartext Storage of Sensitive Information</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Ben Law reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<ul>\n<li>Do not click web links or open attachments in unsolicited email messages.</li>\n<li>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</li>\n<li>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</li>\n</ul>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-15</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-15</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-04",
        "title": "Schneider Electric SCADAPack x70 Products",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-04",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-04.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality.</strong></p>\n<p>The following versions of Schneider Electric SCADAPack x70 Products are affected:</p>\n<ul>\n<li>SCADAPack 47x vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 47xi vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 47xd vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 470R vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 57x vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 3xx vers:all/* (CVE-2026-81861)</li>\n<li>SCADAPack 32 vers:all/* (CVE-2026-81861)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.5</td>\n<td>Schneider Electric</td>\n<td>Schneider Electric SCADAPack x70 Products</td>\n<td>Insufficiently Protected Credentials</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Energy</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>France</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81861</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>There is an insufficiently protected credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81861\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Schneider Electric SCADAPack x70 Products</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Schneider Electric</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R, SCADAPack 57x, SCADAPack 3xx, SCADAPack 32</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Implement the Role-Based Access Control (RBAC) feature and follow the SCADAPack documentation sections Security Guidelines for Administrators and Working with Role-Based Access Control. RBAC is the recommended access control mechanism for SCADAPack 47x devices and should be used in place of the Secure Lock feature. The Secure Lock feature is legacy functionality retained for backward compatibility with existing deployments and should only be used where required to support legacy system requirements. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, apply the following standard practices to reduce the risk of exploitation:&nbsp;</p>\n<ul>\n<li>Configure network segmentation to restrict access between trusted and untrusted networks.&nbsp;</li>\n<li>Enable and implement the RTU firewall service to restrict unauthorized access to device services and reduce the attack surface.&nbsp;</li>\n</ul>\n<p>Documentation available in <a href=\"https://www.se.com/ww/en/download/document/RemoteConnect/\">RemoteConnect and SCADAPack x70 Utilities | Schneider Electric</a>&nbsp;<br><a href=\"https://www.se.com/ww/en/download/document/RemoteConnect/\">https://www.se.com/ww/en/download/document/RemoteConnect/</a></p>\n<p><strong>Mitigation</strong><br>Ensure setup of network segmentation to restrict access between trusted and untrusted networks and implementation of the RTU Firewall Service to restrict unauthorized access to services. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, implement all best practices referenced in the SCADAPack Cybersecurity Guide. Documentation available in <a href=\"https://www.se.com/ww/en/download/document/RemoteConnect/\">RemoteConnect and SCADAPack x70 Utilities | Schneider Electric</a>&nbsp;<br><a href=\"https://www.se.com/ww/en/download/document/RemoteConnect/\">https://www.se.com/ww/en/download/document/RemoteConnect/</a></p>\n<p><strong>Mitigation</strong></p>\n<p>For more information see the associated Schneider Electric security advisory SEVD-2026-251-03 Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-251-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=SEVD-2026-251-03.pdf\">PDF Version</a>, <a href=\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-251-03&amp;p_enDocType=Security+and+Safety+Notice&amp;p_File_Name=sevd-2026-251-03.json\">CSAF Version</a>.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/522.html\">CWE-522 Insufficiently Protected Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abhinav Agarwal reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Security Recommendations</h2>\n<p>Schneider Electric strongly recommends the following industry cybersecurity best practices:</p>\n<ul>\n<li>Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.&nbsp;</li>\n<li>Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.&nbsp;</li>\n<li>Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.&nbsp;</li>\n<li>Never connect programming software to any network other than the network intended for that device.&nbsp;</li>\n<li>Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.&nbsp;</li>\n<li>Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.&nbsp;</li>\n<li>Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.&nbsp;</li>\n<li>When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.&nbsp;</li>\n</ul>\n<p>For more information refer to the <a href=\"https://www.se.com/us/en/download/document/7EN52-0390/\">Schneider Electric Recommended Cybersecurity Best Practices</a> document.</p>\n<hr>\n<h2>For More Information</h2>\n<p>This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: <a href=\"https://www.se.com/ww/en/work/solutions/cybersecurity/\">https://www.se.com/ww/en/work/solutions/cybersecurity/</a>. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: <a href=\"https://www.se.com/ww/en/work/support/cybersecurity/overview.js\">https://www.se.com/ww/en/work/support/cybersecurity/overview.js</a>p</p>\n<hr>\n<h2>LEGAL DISCLAIMER</h2>\n<p>THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION</p>\n<hr>\n<h2>About Schneider Electric</h2>\n<p>Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On.&nbsp;</p>\n<p>Our mission is to be the trusted partner in Sustainability and Efficiency.&nbsp;</p>\n<p>We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers.&nbsp;</p>\n<p>We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all.&nbsp;</p>\n<p><a href=\"https://www.se.com\">www.se.com</a></p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.&nbsp;</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.&nbsp;</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.&nbsp;</li>\n<li>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-251-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-08</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-08</td>\n<td>1</td>\n<td>Original Release</td>\n</tr>\n<tr>\n<td>2026-09-15</td>\n<td>2</td>\n<td>Initial CISA Republication of Schneider Electric SEVD-2026-251-03 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-06",
        "title": "Siemens Mendix SAML",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-06",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-06.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version.</strong></p>\n<p>The following versions of Siemens Mendix SAML are affected:</p>\n<ul>\n<li>Mendix SAML (Mendix 10 compatible) vers:intdot/&lt;4.2.3 (CVE-2026-80465)</li>\n<li>Mendix SAML (Mendix 11 compatible) vers:intdot/&lt;4.2.3 (CVE-2026-80465)</li>\n<li>Mendix SAML (Mendix 9.24 compatible) vers:intdot/&lt;3.6.27 (CVE-2026-80465)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.7</td>\n<td>Siemens</td>\n<td>Siemens Mendix SAML</td>\n<td>Improper Verification of Cryptographic Signature</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-80465</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-80465\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Mendix SAML</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Mendix SAML (Mendix 10 compatible) &lt; V4.2.3, Mendix SAML (Mendix 11 compatible) &lt; V4.2.3, Mendix SAML (Mendix 9.24 compatible) &lt; V3.6.27</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V3.6.27 or later version<br><a href=\"https://marketplace.mendix.com/link/component/1174\">https://marketplace.mendix.com/link/component/1174</a></p>\n<p><strong>Vendor fix</strong><br>Update to V4.2.3 or later version<br><a href=\"https://marketplace.mendix.com/link/component/1174\">https://marketplace.mendix.com/link/component/1174</a></p>\n<p><strong>Vendor fix</strong><br>Update to V4.2.3 or later version<br><a href=\"https://marketplace.mendix.com/link/component/1174\">https://marketplace.mendix.com/link/component/1174</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/347.html\">CWE-347 Improper Verification of Cryptographic Signature</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Siemens ProductCERT reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to <a href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">Siemens' operational guidelines for Industrial Security</a>, and following the recommendations in the product manuals.&nbsp;</p>\n<p>Additional information on Industrial Security by Siemens can be found at: <a href=\"https://www.siemens.com/industrialsecurity\">https://www.siemens.com/industrialsecurity</a></p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: <a href=\"https://www.siemens.com/cert/advisories\">https://www.siemens.com/cert/advisories</a></p>\n<p>For more information see the associated Siemens security advisory SSA-887643 in <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-887643.html\">HTML</a> and <a href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-887643.json\">CSAF</a>.</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: <a href=\"https://www.siemens.com/productcert/terms-of-use\">https://www.siemens.com/productcert/terms-of-use</a>.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-887643.html\">SSA-887643</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-03</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-03</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-09-15</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-887643 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-02",
        "title": "W\u00e4rtsil\u00e4 FOS-Onboard",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client.</strong></p>\n<p>The following versions of W\u00e4rtsil\u00e4 FOS-Onboard are affected:</p>\n<ul>\n<li>FOS-Onboard 5.07.0923.01 (CVE-2026-78225, CVE-2026-81855)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.1</td>\n<td>W\u00e4rtsil\u00e4</td>\n<td>W\u00e4rtsil\u00e4 FOS-Onboard</td>\n<td>Use of Hard-coded Cryptographic Key</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Finland</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-78225</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A hardcoded cryptographic server key vulnerability exists in the deployer-ng Update Controller component of W\u00e4rtsil\u00e4 FOS-Onboard.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-78225\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>W\u00e4rtsil\u00e4 FOS-Onboard</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>W\u00e4rtsil\u00e4</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>W\u00e4rtsil\u00e4 FOS-Onboard: 5.07.0923.01</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>W\u00e4rtsil\u00e4 states that the vulnerabilities are not exploitable when the product is installed as recommended, and has developed a security patch. Users are also directed to contact W\u00e4rtsil\u00e4 to obtain and install the patch. To obtain and install the latest patch, contact W\u00e4rtsil\u00e4:&nbsp;<br><a href=\"https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact\">https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.5</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81855</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A hardcoded cryptographic client authentication key vulnerability exists in the robot testing framework component of W\u00e4rtsil\u00e4 FOS-Onboard.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81855\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>W\u00e4rtsil\u00e4 FOS-Onboard</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>W\u00e4rtsil\u00e4</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>W\u00e4rtsil\u00e4 FOS-Onboard: 5.07.0923.01</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>W\u00e4rtsil\u00e4 states that the vulnerabilities are not exploitable when the product is installed as recommended, and has developed a security patch. Users are also directed to contact W\u00e4rtsil\u00e4 to obtain and install the patch. To obtain and install the latest patch, contact W\u00e4rtsil\u00e4:&nbsp;<br><a href=\"https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact\">https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.1</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.3</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Cydome Security Ltd reported these vulnerabilities to W\u00e4rtsil\u00e4 and CISA</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.&nbsp;</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.&nbsp;</li>\n<li>Locate control system networks and remote devices behind firewalls and isolating them from business networks.&nbsp;</li>\n<li>When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:&nbsp;</p>\n<ul>\n<li>Do not click web links or open attachments in unsolicited email messages.&nbsp;</li>\n<li>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.&nbsp;</li>\n<li>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</li>\n</ul>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-15</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-15</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-01",
        "title": "Digital Watchdog VMAX DVR and NVR Product Lineups",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could grant full administrative control of the device, allowing an attacker to view live and recorded surveillance, alter device configurations, and use the device as a network pivot point.</strong></p>\n<p>The following versions of Digital Watchdog VMAX DVR and NVR Product Lineups are affected:</p>\n<ul>\n<li>VMAX A1 G4 DVRs vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372)</li>\n<li>VMAX IP G4 NVRs vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372)</li>\n<li>VMAX A1 PLUS vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372)</li>\n<li>VA1G4 Recorder vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372)</li>\n<li>VG4 Recorder vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 9.6</td>\n<td>Digital Watchdog</td>\n<td>Digital Watchdog VMAX DVR and NVR Product Lineups</td>\n<td>Missing Authentication for Critical Function, Use of Hard-coded Credentials, Missing Authorization, Predictable Seed in Pseudo-Random Number Generator (PRNG)</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Commercial Facilities, Government Services and Facilities, Healthcare and Public Health, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-68953</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products are vulnerable to an authentication bypass that allows unauthenticated remote attackers to disclose sensitive device information, including administrator credentials in plaintext, by sending crafted HTTP(S) requests.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-68953\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.5</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-66890</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products use hard-coded credentials, which could allow remote access to files with root privileges where FTP is reachable.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-66890\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.6</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-68070</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products are missing authentication for a critical function, which could allow an attacker to run as root and pass received bytes directly to a system command.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-68070\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-68950</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products use hard-coded credentials, which could allow an attacker to run the ftpd service as root, providing remote root file access where FTP is reachable.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-68950\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/798.html\">CWE-798 Use of Hard-coded Credentials</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-66887</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products are missing authorization on state-changing CGIs and session checks are not performed.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-66887\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>9.6</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-66372</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The affected products use insufficiently random values, which allows web session tokens to be predictable, bounding token entropy to the seed space.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-66372\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Digital Watchdog VMAX DVR and NVR Product Lineups</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Digital Watchdog</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Digital Watchdog VMAX A1 G4 DVRs: vers:all/*, Digital Watchdog VMAX IP G4 NVRs: vers:all/*, Digital Watchdog VMAX A1 PLUS: vers:all/*, Digital Watchdog VA1G4 Recorder: vers:all/*, Digital Watchdog VG4 Recorder: vers:all/*</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Digital Watchdog has released updated firmware for the affected products. Users should download and install the updated firmware for their model at:&nbsp;<br><a href=\"https://digital-watchdog.com/downloads/\">https://digital-watchdog.com/downloads/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/337.html\">CWE-337 Predictable Seed in Pseudo-Random Number Generator (PRNG)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.8</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Scot Berner of TrustedSec reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<ul>\n<li>Do not click web links or open attachments in unsolicited email messages.</li>\n<li>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</li>\n<li>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</li>\n</ul>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-15</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-15</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/resources-tools/resources/protecting-tokens-and-assertions-forgery-theft-and-misuse-implementation-recommendations-agencies",
        "title": "Protecting Tokens and Assertions from Forgery, Theft, and Misuse: Implementation Recommendations for Agencies and Cloud Service Providers",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/resources-tools/resources/protecting-tokens-and-assertions-forgery-theft-and-misuse-implementation-recommendations-agencies",
        "summary": "<p>Developed by the National Institute of Standards and Technology (NIST) and CISA, this <a href=\"https://csrc.nist.gov/pubs/ir/8587/final\" target=\"_blank\">interagency report</a> provides federal agencies and cloud service providers with guidelines to protect the identity assertions, access tokens, and cryptographic mechanisms that support modern authentication and authorization. As agencies adopt hybrid and multi-cloud environments, single sign-on, federation, and application programming interface (API)-based access increasingly depend on signed tokens and assertions that adversaries may target for forgery, theft, and misuse to move laterally across enterprise networks and access sensitive data.</p>\n<p>This final report updates the initial public draft and incorporates feedback on token validation, secrets management, and detection at scale, as well as input from government and industry experts that CISA gathered through its Joint Cyber Defense Collaborative. The report expands on NIST Special Publication <a href=\"https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final\" target=\"_blank\">Security and Privacy Controls for Information Systems</a> and Organizations and supports <a href=\"https://www.congress.gov/crs_external_products/IN/HTML/IN12570.html\" target=\"_blank\">Executive Order 14306</a> on secure software development practices. It provides architectural considerations and emphasizes the importance of <a href=\"https://www.cisa.gov/securebydesign\">Secure by Design</a> principles for interoperable defense across cloud environments.</p>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-07",
        "title": "Siemens Teamcenter",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-07",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-07.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions.</strong></p>\n<p>The following versions of Siemens Teamcenter are affected:</p>\n<ul>\n<li>Teamcenter V2412 vers:intdot/&lt;2412.0013 (CVE-2026-58113)</li>\n<li>Teamcenter V2506 vers:intdot/&lt;2506.0010 (CVE-2026-58113)</li>\n<li>Teamcenter V2512 vers:intdot/&lt;2512.2607 (CVE-2026-58113)</li>\n<li>Teamcenter V2606 vers:intdot/&lt;2606.2607 (CVE-2026-58113)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 6.1</td>\n<td>Siemens</td>\n<td>Siemens Teamcenter</td>\n<td>Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing, Information Technology</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Germany</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-58113</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-58113\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Siemens Teamcenter</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Siemens</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Teamcenter V2412 &lt; V2412.0013, Teamcenter V2506 &lt; V2506.0010, Teamcenter V2512 &lt; V2512.2607, Teamcenter V2606 &lt; V2606.2607</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>Update to V2412.0013 or later version<br><a href=\"https://support.sw.siemens.com/product/282219420/\">https://support.sw.siemens.com/product/282219420/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2506.0010 or later version<br><a href=\"https://support.sw.siemens.com/product/282219420/\">https://support.sw.siemens.com/product/282219420/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2512.2607 or later version<br><a href=\"https://support.sw.siemens.com/product/282219420/\">https://support.sw.siemens.com/product/282219420/</a></p>\n<p><strong>Vendor fix</strong><br>Update to V2606.2607 or later version<br><a href=\"https://support.sw.siemens.com/product/282219420/\">https://support.sw.siemens.com/product/282219420/</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>6.1</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Enzo Alvarez from Bishop Fox reported this vulnerability to Siemens.</li>\n</ul>\n<hr>\n<h2>General Recommendations</h2>\n<p>As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to <a href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">Siemens' operational guidelines for industrial security</a> and following recommendations in the product manuals.</p>\n<p>Additional information on Industrial Security by Siemens can be found at: <a href=\"https://www.siemens.com/industrialsecurity\">https://www.siemens.com/industrialsecurity</a>&nbsp;</p>\n<hr>\n<h2>Additional Resources</h2>\n<p>For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: <a href=\"https://www.siemens.com/cert/advisories\">https://www.siemens.com/cert/advisories</a>&nbsp;</p>\n<p>Additional information on industrial security by Siemens can be found on the <a href=\"https://www.siemens.com/industrialsecurity\">Siemens industrial security webpage</a></p>\n<p>For more information see the associated Siemens security advisory SSA-157465 in <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-157465.html\">HTML</a> and <a href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-157465.json\">CSAF</a>.</p>\n<hr>\n<h2>Terms of Use</h2>\n<p>The use of Siemens Security Advisories is subject to the terms and conditions listed on: <a href=\"https://www.siemens.com/productcert/terms-of-use\">https://www.siemens.com/productcert/terms-of-use</a>.</p>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.</p>\n<ul>\n<li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.</li>\n<li>Locate control system networks and remote devices behind firewalls and isolate them from business networks.</li>\n<li>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.</li>\n</ul>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<hr>\n<h2>Advisory Conversion Disclaimer</h2>\n<p>This ICSA is a verbatim republication of Siemens ProductCERT <a href=\"https://cert-portal.siemens.com/productcert/html/ssa-157465.html\">SSA-157465</a> from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.</p>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-08</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-08</td>\n<td>1</td>\n<td>Publication Date</td>\n</tr>\n<tr>\n<td>2026-09-15</td>\n<td>2</td>\n<td>Initial CISA Republication of Siemens ProductCERT SSA-157465 advisory</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Tue, 15 Sep 26 12:00:00 +0000",
        "last_updated": "Tue, 15 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/14/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/14/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-76461\" target=\"_blank\">CVE-2026-76461</a> Cisco Secure Email Gateway SQL Injection Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>",
        "summary_is_html": true,
        "first_seen": "Mon, 14 Sep 26 12:00:00 +0000",
        "last_updated": "Mon, 14 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/11/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Three Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/11/cisa-adds-three-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added three new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42016\" target=\"_blank\">CVE-2026-42016</a> JFrog Artifactory Incorrect Authorization Vulnerability&nbsp;</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-42018\" target=\"_blank\">CVE-2026-42018</a> JFrog Artifactory Improper Authentication Vulnerability&nbsp;</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-84869\" target=\"_blank\">CVE-2026-84869</a> ConnectWise ScreenConnect Improper Privilege Management and Missing Authorization Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>\n<p>&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 11 Sep 26 12:00:00 +0000",
        "last_updated": "Fri, 11 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/11/cisa-adds-one-known-exploited-vulnerability-catalog",
        "title": "CISA Adds One Known Exploited Vulnerability to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/11/cisa-adds-one-known-exploited-vulnerability-catalog",
        "summary": "<p>CISA has added one new vulnerability to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-85706\" target=\"_blank\">CVE-2026-85706</a> GitLab Community Edition and Enterprise Edition Path Traversal Vulnerability</li>\n</ul>\n<p>This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog/reducing-significant-risk-known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.</p>",
        "summary_is_html": true,
        "first_seen": "Fri, 11 Sep 26 12:00:00 +0000",
        "last_updated": "Fri, 11 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-253-01",
        "title": "AVEVA Pipeline Integrity Monitor",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-253-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-253-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session.</strong></p>\n<p>The following versions of AVEVA Pipeline Integrity Monitor are affected:</p>\n<ul>\n<li>AVEVA Pipeline Integrity Monitor &lt;=2025_SP1_P1_build_7.1.9580.8513 (CVE-2026-81821, CVE-2026-81822, CVE-2026-81823, CVE-2026-81824)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.4</td>\n<td>AVEVA</td>\n<td>AVEVA Pipeline Integrity Monitor</td>\n<td>Use of Hard-coded Cryptographic Key, Use of a Broken or Risky Cryptographic Algorithm, Missing Authorization, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United Kingdom</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81821</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow a miscreant with read access to PIMBoards project files to decrypt and view sensitive information.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81821\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Pipeline Integrity Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Pipeline Integrity Monitor: &lt;=2025_SP1_P1_build_7.1.9580.8513</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>AVEVA recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. Customers using affected product versions or affected PIMBoards project files should take the following actions to mitigate the risk of exploit:&nbsp;</p>\n<ul>\n<li>Apply AVEVA Pipeline Integrity Monitor 2025 SP1 P2 Security Update and migrate old project files.&nbsp;</li>\n<li>For project files that cannot be migrated (e.g. backups or transient copies), evaluate the risk of potential password leakage from these files and implement stricter read access controls to protect these unsafe files.</li>\n<li>Require AVEVA Pipeline Integrity Monitor PIMBoards users to change their passwords.</li>\n</ul>\n<p><strong>Vendor fix</strong><br>Important: PIMBoards Project Files migration from older versions to AVEVA Pipeline Integrity Monitor 2025 SP1 P2 is one-way due to the changes in password hashing algorithms and end-user managed encryption keys.</p>\n<p><strong>Mitigation</strong><br>For more information, see AVEVA security bulletin AVEVA-2026-006.&nbsp;<br><a href=\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf\">https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/321.html\">CWE-321 Use of Hard-coded Cryptographic Key</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81822</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow a miscreant with read access to PIMBoards project files to reverse engineer PIMBoards users' app-native passwords through computational brute-forcing of weak hashes, potentially allowing elevation to a PIMBoards administrator user.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81822\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Pipeline Integrity Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Pipeline Integrity Monitor: &lt;=2025_SP1_P1_build_7.1.9580.8513</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>AVEVA recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. Customers using affected product versions or affected PIMBoards project files should take the following actions to mitigate the risk of exploit:&nbsp;</p>\n<ul>\n<li>Apply AVEVA Pipeline Integrity Monitor 2025 SP1 P2 Security Update and migrate old project files.&nbsp;</li>\n<li>For project files that cannot be migrated (e.g. backups or transient copies), evaluate the risk of potential password leakage from these files and implement stricter read access controls to protect these unsafe files.</li>\n<li>Require AVEVA Pipeline Integrity Monitor PIMBoards users to change their passwords.</li>\n</ul>\n<p><strong>Vendor fix</strong><br>Important: PIMBoards Project Files migration from older versions to AVEVA Pipeline Integrity Monitor 2025 SP1 P2 is one-way due to the changes in password hashing algorithms and end-user managed encryption keys.</p>\n<p><strong>Mitigation</strong><br>For more information, see AVEVA security bulletin AVEVA-2026-006.&nbsp;<br><a href=\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf\">https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/327.html\">CWE-327 Use of a Broken or Risky Cryptographic Algorithm</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.4</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N\">CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81823</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow an unauthenticated miscreant to perform read operations intended only for PIMBoards users, resulting in information disclosure. Write operations are not impacted.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81823\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Pipeline Integrity Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Pipeline Integrity Monitor: &lt;=2025_SP1_P1_build_7.1.9580.8513</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>AVEVA recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. Customers using affected product versions or affected PIMBoards project files should take the following actions to mitigate the risk of exploit:&nbsp;</p>\n<ul>\n<li>Apply AVEVA Pipeline Integrity Monitor 2025 SP1 P2 Security Update and migrate old project files.&nbsp;</li>\n<li>For project files that cannot be migrated (e.g. backups or transient copies), evaluate the risk of potential password leakage from these files and implement stricter read access controls to protect these unsafe files.</li>\n<li>Require AVEVA Pipeline Integrity Monitor PIMBoards users to change their passwords.</li>\n</ul>\n<p><strong>Vendor fix</strong><br>Important: PIMBoards Project Files migration from older versions to AVEVA Pipeline Integrity Monitor 2025 SP1 P2 is one-way due to the changes in password hashing algorithms and end-user managed encryption keys.</p>\n<p><strong>Mitigation</strong><br>For more information, see AVEVA security bulletin AVEVA-2026-006.&nbsp;<br><a href=\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf\">https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>5.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.9</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-81824</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The vulnerability, if exploited, could allow a miscreant to run arbitrary JavaScript code in a browser session of a PIMBoards user who was socially engineered to click on a malicious link.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-81824\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>AVEVA Pipeline Integrity Monitor</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>AVEVA</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>AVEVA Pipeline Integrity Monitor: &lt;=2025_SP1_P1_build_7.1.9580.8513</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>AVEVA recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. Customers using affected product versions or affected PIMBoards project files should take the following actions to mitigate the risk of exploit:&nbsp;</p>\n<ul>\n<li>Apply AVEVA Pipeline Integrity Monitor 2025 SP1 P2 Security Update and migrate old project files.&nbsp;</li>\n<li>For project files that cannot be migrated (e.g. backups or transient copies), evaluate the risk of potential password leakage from these files and implement stricter read access controls to protect these unsafe files.</li>\n<li>Require AVEVA Pipeline Integrity Monitor PIMBoards users to change their passwords.</li>\n</ul>\n<p><strong>Vendor fix</strong><br>Important: PIMBoards Project Files migration from older versions to AVEVA Pipeline Integrity Monitor 2025 SP1 P2 is one-way due to the changes in password hashing algorithms and end-user managed encryption keys.</p>\n<p><strong>Mitigation</strong><br>For more information, see AVEVA security bulletin AVEVA-2026-006.&nbsp;<br><a href=\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf\">https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2026-006.pdf</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/79.html\">CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>4.7</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>6.3</td>\n<td>MEDIUM</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:H/SA:H\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>AVEVA reported vulnerabilities CVE-2026-81821 and CVE-2026-81822 to CISA.</li>\n<li>Adham Khairy Ramadan (0xadham) reported vulnerabilities CVE-2026-81823 and CVE-2026-81824 to AVEVA through HackerOne.&nbsp;</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-10</td>\n<td>1</td>\n<td>Initial Republication of AVEVA security bulletin AVEVA-2026-006</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 10 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 10 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-253-02",
        "title": "Orthanc DICOM Server",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-253-02",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-253-02.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash of the Orthanc process and a denial-of-service condition.</strong></p>\n<p>The following versions of Orthanc DICOM Server are affected:</p>\n<ul>\n<li>Orthanc DICOM Server &lt;1.13.0. (CVE-2026-87020)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.1</td>\n<td>Orthanc</td>\n<td>Orthanc DICOM Server</td>\n<td>Integer Overflow or Wraparound</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>Belgium</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-87020</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>An integer overflow in a specified pitch and buffer-size computation leads to a heap out-of-bounds write when Orthanc decodes an attacker-supplied PNG.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-87020\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>Orthanc DICOM Server</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>Orthanc</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>Orthanc DICOM Server: &lt;1.13.0.</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>Orthanc recommends users update to v1.13.0.&nbsp;<br><a href=\"https://orthanc.uclouvain.be/downloads/index.html\">https://orthanc.uclouvain.be/downloads/index.html</a></p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/190.html\">CWE-190 Integer Overflow or Wraparound</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Andrej Tomci reported this vulnerability to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-10</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 10 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 10 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/alerts/2026/09/10/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "title": "CISA Adds Two Known Exploited Vulnerabilities to Catalog",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/alerts/2026/09/10/cisa-adds-two-known-exploited-vulnerabilities-catalog",
        "summary": "<p>CISA has added two new vulnerabilities to its <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">Known Exploited Vulnerabilities (KEV) Catalog</a>, based on evidence of active exploitation.</p>\n<ul>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-67277\" target=\"_blank\">CVE-2026-67277</a> MikroTik RouterOS Missing Authentication for Critical Function Vulnerability</li>\n<li><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-86060\">CVE-2026-86060</a> MikroTik RouterOS Improper Neutralization of Argument Delimiters in a Command Vulnerability</li>\n</ul>\n<p>These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.</p>\n<p><a href=\"https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk\">Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk</a> establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA\u2019s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.</p>\n<p>While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog\">KEV Catalog vulnerabilities</a>. CISA will continue to add vulnerabilities to the catalog that meet the <a href=\"https://www.cisa.gov/known-exploited-vulnerabilities\">specified criteria</a>.</p>\n<p>Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA\u2019s <a href=\"https://cisasurvey.gov1.qualtrics.com/jfe/form/SV_1Zwu52kgK2OYf3w\" target=\"_blank\">KEV Nomination Form</a>. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.&nbsp;</p>",
        "summary_is_html": true,
        "first_seen": "Thu, 10 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 10 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-253-01",
        "title": "NextGen Healthcare Mirth Connect",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-253-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-253-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to exfiltrate date or cause a denial-of-service condition.</strong></p>\n<p>The following versions of NextGen Healthcare Mirth Connect are affected:</p>\n<ul>\n<li>Mirth Connect &lt;=v4.7.1 (CVE-2026-82583, CVE-2026-78224, CVE-2026-82578)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.3</td>\n<td>NextGen Healthcare</td>\n<td>NextGen Healthcare Mirth Connect</td>\n<td>Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Restriction of XML External Entity Reference</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Healthcare and Public Health</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-82583</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>NextGen Connect (Mirth Connect) versions 4.7.1 and earlier allow an authenticated user to execute arbitrary SQL through a Database Connector API, which could result in disclosure of stored credentials for connected systems, arbitrary file write, and a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82583\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>NextGen Healthcare Mirth Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>NextGen Healthcare</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>NextGen Healthcare Mirth Connect: &lt;=v4.7.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>NextGen recommends users update Mirth Connect v4.7.2 or later. Users can download the latest version from the NextGen Healthcare customer portal.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/89.html\">CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.3</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-78224</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The XSLT Transformer Step builds a bare TransformerFactory without the proper security options set, so XXE injection can allow data exfiltration and denial-of-service attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-78224\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>NextGen Healthcare Mirth Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>NextGen Healthcare</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>NextGen Healthcare Mirth Connect: &lt;=v4.7.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>NextGen recommends users update Mirth Connect v4.7.2 or later. Users can download the latest version from the NextGen Healthcare customer portal.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/611.html\">CWE-611 Improper Restriction of XML External Entity Reference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.2</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-82578</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>When XML batch processing is turned on and the XPath option is selected, the raw batch input goes through a default XPath/JAXP setup with no entity restrictions, so XXE injection can allow data exfiltration and denial-of-service attacks.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-82578\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>NextGen Healthcare Mirth Connect</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>NextGen Healthcare</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>NextGen Healthcare Mirth Connect: &lt;=v4.7.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Vendor fix</strong><br>NextGen recommends users update Mirth Connect v4.7.2 or later. Users can download the latest version from the NextGen Healthcare customer portal.</p>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/611.html\">CWE-611 Improper Restriction of XML External Entity Reference</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Abhinav Agarwal reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-09-10</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-09-10</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 10 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 10 Sep 26 12:00:00 +0000"
    },
    {
        "id": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-01",
        "title": "ST Engineering iDirect iQ-Series Terminals (Update A)",
        "source": "CISA Cybersecurity Advisory",
        "source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-183-01",
        "summary": "<p><a href=\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-183-01.json\"><strong>View CSAF</strong></a></p>\n<h2>Summary</h2>\n<p><strong>Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition.</strong></p>\n<p>The following versions of ST Engineering iDirect iQ-Series Terminals (Update A) are affected:</p>\n<ul>\n<li>Evolution iQ\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058)</li>\n<li>3315\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058)</li>\n<li>9\u2011Series terminals &lt;=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058)</li>\n</ul>\n<div class=\"csaf-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS</th>\n<th role=\"columnheader\">Vendor</th>\n<th role=\"columnheader\">Equipment</th>\n<th role=\"columnheader\">Vulnerabilities</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>v3 8.8</td>\n<td>ST Engineering iDirect</td>\n<td>ST Engineering iDirect iQ-Series Terminals&nbsp;</td>\n<td>Missing Authentication for Critical Function, Cross-Site Request Forgery (CSRF), Missing Authorization, Exposure of Sensitive System Information to an Unauthorized Control Sphere</td>\n</tr>\n</tbody>\n</table>\n</div>\n<h3>Background</h3>\n<ul>\n<li><strong>Critical Infrastructure Sectors: </strong>Communications, Defense Industrial Base, Energy, Government Services and Facilities, Transportation Systems</li>\n<li><strong>Countries/Areas Deployed: </strong>Worldwide</li>\n<li><strong>Company Headquarters Location: </strong>United States</li>\n</ul>\n<hr>\n<h2>Vulnerabilities</h2>\n<div class=\"csaf-accordion\">\n<p><a class=\"csaf-accordion-toggle-all\" href=\"#\">Expand All +</a></p>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38059</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The iDirect iQ200 exposes the /api/identity and /api/ REST API endpoints without authentication. An unauthenticated attacker with network access can retrieve sensitive device information including the serial number, Device ID (DID), Terminal Private Key identifier (TPK), MAC address, and exact firmware version. The DID and TPK are used for satellite network authentication in the iDirect platform, potentially enabling terminal impersonation and network reconnaissance.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38059\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.3.0 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net.<br><a href=\"https://support.idirect.net\">https://support.idirect.net</a></p>\n<ul>\n<li>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</li>\n<li>Avoid exposing administrative APIs to the public internet.</li>\n<li>Enforce strong authentication practices.</li>\n<li>Monitor for anomalous API activity and unexpected device reboots.</li>\n</ul>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/306.html\">CWE-306 Missing Authentication for Critical Function</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>7.5</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\">CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38057</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The iDirect iQ200 does not validate CSRF tokens on state-changing API endpoints after authentication. The /api/reboot endpoint accepts POST requests authenticated solely by a session cookie that lacks the SameSite attribute. A remote attacker can host a malicious web page that, when visited by an authenticated administrator, automatically submits a cross-site POST request causing an immediate device reboot and satellite link loss. Repeated attacks can sustain a denial-of-service condition.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38057\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.3.0 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net.<br><a href=\"https://support.idirect.net\">https://support.idirect.net</a></p>\n<ul>\n<li>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</li>\n<li>Avoid exposing administrative APIs to the public internet.</li>\n<li>Enforce strong authentication practices.</li>\n<li>Monitor for anomalous API activity and unexpected device reboots.</li>\n</ul>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/352.html\">CWE-352 Cross-Site Request Forgery (CSRF)</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H\">CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>7</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38056</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>A local privilege escalation vulnerability exists in the iDirect iQ200 VSAT terminal running firmware 23.0.1.0. The iQ200 is a rackmount satellite modem deployed across oil and gas, maritime, defense, and remote infrastructure as the primary, and often sole communications link for offshore rigs, vessels, and remote sites. Important context: the device ships from the factory with a pre-configured low-privilege local user account. This account is intended for field technicians who need shell access for maintenance and diagnostics but should not have full administrative control over the device. This built-in account provides the initial access required to exploit this vulnerability. No additional credentials need to be obtained or brute-forced.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38056\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.3.0 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net.<br><a href=\"https://support.idirect.net\">https://support.idirect.net</a></p>\n<ul>\n<li>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</li>\n<li>Avoid exposing administrative APIs to the public internet.</li>\n<li>Enforce strong authentication practices.</li>\n<li>Monitor for anomalous API activity and unexpected device reboots.</li>\n</ul>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/862.html\">CWE-862 Missing Authorization</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.8</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\">CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>9.4</td>\n<td>CRITICAL</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\">CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n<div class=\"csaf-accordion-item\">\n<h3><a class=\"csaf-accordion-toggle\" href=\"#\">CVE-2026-38058</a></h3>\n<div class=\"csaf-accordion-content\">\n<p>The endpoint on the iDirect iQ200 VSAT terminal returns the complete device configuration as JSON, including the SECURITY section which contains MD5-crypt password hashes for the root SSH and web administration accounts. Any user with valid web credentials can extract these hashes and crack them offline using commodity hardware.</p>\n<p><a href=\"https://www.cve.org/CVERecord?id=CVE-2026-38058\">View CVE Details</a></p>\n<hr>\n<h4>Affected Products</h4>\n<h5>ST Engineering iDirect iQ-Series Terminals (Update A)</h5>\n<div class=\"ics-vendor-version-status\">\n<div class=\"ics-vendor\"><strong>Vendor:</strong><br>ST Engineering iDirect</div>\n<div class=\"ics-version\"><strong>Product Version:</strong><br>ST Engineering iDirect Evolution iQ\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 3315\u2011Series terminals: &lt;=4.5.2.1, ST Engineering iDirect 9\u2011Series terminals: &lt;=4.5.2.1</div>\n<div class=\"ics-status\"><strong>Product Status:</strong><br>known_affected</div>\n</div>\n<div class=\"ics-remediations\">\n<h6>Remediations</h6>\n<p><strong>Mitigation</strong><br>ST Engineering iDirect has fixed the vulnerabilities and recommend users update the software to version 4.5.3.0 or newer.</p>\n<p><strong>Mitigation</strong><br>Registered users are able to download patches from the iDirect Support Portal https://support.idirect.net.<br><a href=\"https://support.idirect.net\">https://support.idirect.net</a></p>\n<ul>\n<li>Restrict management interfaces to trusted networks (e.g., VPN, ACLs).</li>\n<li>Avoid exposing administrative APIs to the public internet.</li>\n<li>Enforce strong authentication practices.</li>\n<li>Monitor for anomalous API activity and unexpected device reboots.</li>\n</ul>\n</div>\n<p><strong>Relevant CWE:</strong> <a href=\"https://cwe.mitre.org/data/definitions/497.html\">CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere</a></p>\n<hr>\n<h4>Metrics</h4>\n<div class=\"csaf-table csaf-metrics-table\">\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">CVSS Version</th>\n<th role=\"columnheader\">Base Score</th>\n<th role=\"columnheader\">Base Severity</th>\n<th role=\"columnheader\">Vector String</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>3.1</td>\n<td>8.1</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\">CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N</a></td>\n</tr>\n<tr>\n<td>4.0</td>\n<td>8.6</td>\n<td>HIGH</td>\n<td><a href=\"https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\">CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N</a></td>\n</tr>\n</tbody>\n</table>\n</div>\n</div>\n</div>\n</div>\n<hr>\n<h2>Acknowledgments</h2>\n<ul>\n<li>Ahmed Alqahtani of Aramco reported these vulnerabilities to CISA.</li>\n</ul>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>\n<p>This product is provided subject to this Notification (<a href=\"https://www.cisa.gov/notification\">https://www.cisa.gov/notification</a>) and this Privacy &amp; Use policy (<a href=\"https://www.cisa.gov/privacy-policy\">https://www.cisa.gov/privacy-policy</a>).</p>\n<hr>\n<h2>Recommended Practices</h2>\n<p>CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.</p>\n<p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p>\n<p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p>\n<p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p>\n<p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p>\n<p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p>\n<p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p>\n<p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p>\n<p>CISA also recommends users take the following measures to protect themselves from social engineering attacks:</p>\n<p>Do not click web links or open attachments in unsolicited email messages.</p>\n<p>Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.</p>\n<p>Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.</p>\n<p>No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.</p>\n<hr>\n<h2>Revision History</h2>\n<ul>\n<li><strong>Initial Release Date: </strong>2026-07-02</li>\n</ul>\n<table class=\"tablesaw tablesaw-stack\" data-tablesaw-mode=\"stack\" data-tablesaw-minimap>\n<thead>\n<tr>\n<th role=\"columnheader\" data-tablesaw-priority=\"persist\">Date</th>\n<th role=\"columnheader\">Revision</th>\n<th role=\"columnheader\">Summary</th>\n</tr>\n</thead>\n<tbody>\n<tr>\n<td>2026-07-02</td>\n<td>1</td>\n<td>Initial Publication</td>\n</tr>\n<tr>\n<td>2026-09-10</td>\n<td>2</td>\n<td>Update A - Updated Vulnerabilities and CVSS 4.0 score in Executive Summary. Added CVE-2026-38056 and CVE-2026-38058. Updated Mitigation section with newest product version.</td>\n</tr>\n</tbody>\n</table>\n<hr>\n<h2>Legal Notice and Terms of Use</h2>",
        "summary_is_html": true,
        "first_seen": "Thu, 10 Sep 26 12:00:00 +0000",
        "last_updated": "Thu, 10 Sep 26 12:00:00 +0000"
    }
]