Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Sep 22, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-7273 Zyxel GS1900 Series Switches Stack-Based Buffer Overflow Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-7273 Zyxel GS1900 Series Switches Stack-Based Buffer Overflow Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-39964 Linux Kernel Race Condition Vulnerability CVE-2026-53266 Linux Kernel Out-of-Bounds Write Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-39964 Linux Kernel Race Condition Vulnerability CVE-2026-53266 Linux Kernel Out-of-Bounds Write Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-39682 Linux Kernel Improper Check for Unusual or Exceptional Conditions Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04:…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-39682 Linux Kernel Improper Check for Unusual or Exceptional Conditions Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Schneider Electric Modicon M340 Controller and Communication Modules

View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se.com/us/en/product/BMXNOC0401/network-module-modicon-m340-ethernet-ip-and-modbus-tcp-4-x-rj45/?pageType=product&sourceId=BMXNOC0401: Modicon M340 X80 Ethernet Communication modules, BMXNOE0100 https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/?pageType=product&sourceId=BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module, BMXNOE0110 https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/: Modbus/TCP Ethernet Modicon M340 FactoryCast module product(s). Failure to apply the fix provided below may risk Denial Of Service attack, which could result in the unavailability of the devices. The following versions of Schneider Electric Modicon M340 Controller and Communication Modules are affected: Schneider Electric Ethernet/Serial RTU Module: vers:generic/<SV1.7_IR27 Schneider Electric M580 Global Data module: vers:all/* Schneider Electric Ethernet / Serial RTU Module: vers:all/* Schneider Electric Modbus/TCP Ethernet Modicon M340 module: vers:intdot/<3.60 Schneider Electric Modbus/TCP Ethernet Modicon M340 FactoryCast module: vers:intdot/<6.80 Schneider Electric Modicon M340 Firmware Versions prior to SV3.70 installed on Modicon M340 Controller: All versions CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric Modicon M340 Controller and Communication Modules Improper Input Validation Background Critical Infrastructure Sectors: Chemical, Commercial Facilities, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-6625 CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. View CVE Details Affected Products Schneider Electric Modicon M340 Controller and Communication Modules Vendor: Schneider Electric Product Version: Ethernet / Serial RTU Module All versions, M580 Global Data module All versions, Modicon M340 X80 Ethernet Communication modules All versions, Modbus/TCP Ethernet Modicon M340 module Versions prior to 3.60, Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to 6.80 Product Status: fixed, known_affected Remediations Vendor fix Version 3.60 of BMXNOE0100 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/ Reboot is needed to complete the firmware upgrade Vendor fix Version 6.80 of BMXNOE0110 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/ Reboot is needed to complete the firmware upgrade Vendor fix Version SV3.70 of Modicon M340 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware Vendor fix Version SV1.7 IR27 of BMXNOR0200H includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOR0200H/ethernet-serial-rtu-module-2-x-rj45/ Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: FTP service is disabled by default. Ensure to disable FTP service when not in use. Setup network segmentation and implement a firewall to block all unauthorized access to ports 21/FTP. Use VPN (Virtual Private Networks) tunnels if remote access is required. Mitigation Schneider Electric is establishing a remediation plan for all future versions of: Modicon M340 BMXNOR0200H BMXNGD0100 BMXNOC401 Schneider Electric will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: FTP service is disabled by default. Ensure to disable FTP service when not in use. Setup network segmentation and implement a firewall to block all unauthorized access to ports 21/FTP. Use VPN (Virtual Private Networks) tunnels if remote access is required. Mitigation For more information see the associated Schneider Electric security advisory Modicon M340 Controller and Communication Modules - SEVD-2025-224-05 CSAF Version, Modicon M340 Controller and Communication Modules - SEVD-2025-224-05 PDF Version. Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Place all controllers in locked cabinets and never leave them in the “Program” mode. Never connect programming software to any network other than the network intended for that device. Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-224-05 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-08-12 Date Revision Summary 2025-08-12 1 Original Release 2026-04-14 2 Remediation is available for Modicon M340 2026-08-11 3 Remediation is available for BMXNOR0200H. 2026-09-17 4 Initial CISA Republication of Schneider Electric CPCERT SEVD-2025-224-05 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems.…
Read full source summary
View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control of the system The following versions of ABB Ability Edgenius are affected: Ability Edgenius >=3.2.0.0|<3.2.4.1, 3.2.4.1 (CVE-2026-31431) CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Edgenius Incorrect Resource Transfer Between Spheres Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater, Chemical Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 A Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. The issue originates in the Linux kernel’s cryptographic subsystem and impacts kernels used by most major Linux distributions released since 2017.Successful exploitation requires local code execution, however, in shared, containerized, or multi‑tenant environments this may increase the security risk. View CVE Details Affected Products ABB Ability Edgenius Vendor: ABB Product Version: ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100 Product Status: fixed, known_affected Remediations Vendor fix The problem is corrected in the following product versions: - Edgenius 3.2.4.1 ABB recommends that customers apply the update at earliest convenience. Mitigation Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Refer to section General security recommendations for further advise on how to keep your system secure. Recommended mitigation factors - Limit access to ssh or cockpit - By default, no additional lower privilege users are present on Edgenius installations. Mitigation For more information see the associated ABB PSIRT security advisory 7PAA024620 ABB CYBERSECURITY ADVISORY - PDF Version , ABB CYBERSECURITY ADVISORY - CSAF Version . Relevant CWE: CWE-669 Incorrect Resource Transfer Between Spheres Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What causes the vulnerability? - A flaw was found in the Linux kernel's algif_aead cryptographic algorithm interface. An incorrect 'in-place operation' was introduced, where the source and destination data mappings were different. This could lead to unexpected behavior or data integrity issues during cryptographic operations, potentially impacting the reliability of encrypted communications. What is Edgenius? - ABB Ability™ Edgenius is an edge computing platform that - Connects to control systems, devices, and equipment - Collects and contextualizes operational data - Hosts applications that deliver real-time insights and AI-driven recommendations What might an attacker use the vulnerability to do? - Successful exploitation could enable a local user attacker to gain administrative control of the system node, execute arbitrary code, or cause the node to become unavailable. How could an attacker exploit the vulnerability? - An attacker could exploit this vulnerability after obtaining local access to the system. By invoking the Linux kernel’s affected cryptographic interface (algif_aead), the attacker can trigger incorrect memory handling in the kernel. This allows the attacker to escalate privileges from a normal user to full administrative (root) access on the affected system node Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have local access (physical access or through valid SSH credentials) to an affected system node. What does the update do? - The update resolves the issue by incorporating the security update of the Linux kernel. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited for Edgenius when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA024620 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial version. 2026-09-17 2 Initial CISA Republication of ABB PSIRT 7PAA024620 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Bransys ELD

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthorized access to telemetry data and firmware. The following versions of Bransys ELD are affected: Android <11.00.00 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960) iOS <1.1.54 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960) CVSS Vendor Equipment Vulnerabilities v3 7.5 Bransys Bransys ELD Use of Hard-coded Credentials, Cleartext…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthorized access to telemetry data and firmware. The following versions of Bransys ELD are affected: Android <11.00.00 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960) iOS <1.1.54 (CVE-2026-86520, CVE-2026-86689, CVE-2026-77960) CVSS Vendor Equipment Vulnerabilities v3 7.5 Bransys Bransys ELD Use of Hard-coded Credentials, Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-86520 The affected product is shipped with hardcoded MQTT credentials, which will grant read access to real-time data for every active device across a subset of carriers that were connected to the affected MQTT broker. View CVE Details Affected Products Bransys ELD Vendor: Bransys Product Version: Bransys Android: <11.00.00, Bransys iOS: <1.1.54 Product Status: known_affected Remediations Vendor fix Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-86689 The affected product is susceptible to cleartext transmission of sensitive information, which could allow an attacker to connect to the broker and read all data. View CVE Details Affected Products Bransys ELD Vendor: Bransys Product Version: Bransys Android: <11.00.00, Bransys iOS: <1.1.54 Product Status: known_affected Remediations Vendor fix Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer. Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-77960 The affected product ships with hardcoded FTP credentials which could allow an attacker to connect to the server and read data. View CVE Details Affected Products Bransys ELD Vendor: Bransys Product Version: Bransys Android: <11.00.00, Bransys iOS: <1.1.54 Product Status: known_affected Remediations Vendor fix Bransys recommends that users update their system through the app store. Android users should be on version 11.00.00 or newer. iOS users should be on version 1.1.54 or newer. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Jaime Lightfoot reported these vulnerabilities to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-17 Date Revision Summary 2026-09-17 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of…
Read full source summary
View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown vers:intdot/<=1.5, 1.6 (CVE-2026-13348) CVSS Vendor Equipment Vulnerabilities v3 5.3 Schneider Electric Schneider Electric PowerChute Serial Shutdown Improper Restriction of Excessive Authentication Attempts Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-13348 CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: Schneider Electric Product Version: PowerChute Serial Shutdown Version 1.5 and prior Product Status: fixed, known_affected Remediations Vendor fix Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available for download here: • Windows: https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Reboot needed: Upon installation, the service is automatically restarted. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Specific instructions and hardening guidelines for these remediations can be found in the Security Handbook. Vendor fix Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available for download here: • Linux: https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Reboot needed: Upon installation, the service is automatically restarted. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Specific instructions and hardening guidelines for these remediations can be found in the Security Handbook. For more information see the associated Schneider Electric security advisory Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown - SEVD-2026-223-01 CSAF Version, Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown - SEVD-2026-223-01 PDF Version. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Place all controllers in locked cabinets and never leave them in the “Program” mode. Never connect programming software to any network other than the network intended for that device. Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-223-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Original Release 2026-09-17 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-223-01 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric NetBotz 5 750/755

View CSAF Summary Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could…
Read full source summary
View CSAF Summary Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access. The following versions of Schneider Electric NetBotz 5 750/755 are affected: NetBotz 5 750 vers:intdot/<=5.5.2 (CVE-2026-13336, CVE-2026-13337) NetBotz 5 755 vers:intdot/<=5.5.2 (CVE-2026-13336, CVE-2026-13337) CVSS Vendor Equipment Vulnerabilities v3 6.4 Schneider Electric Schneider Electric NetBotz 5 750/755 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), SQL Injection: Hibernate Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-13336 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux Operating system commands when a system back up is restored that has been maliciously modified. View CVE Details Affected Products Schneider Electric NetBotz 5 750/755 Vendor: Schneider Electric Product Version: NetBotz 5 750 versions 5.5.2 and prior, NetBotz 5 755 Versions 5.5.2 and prior Product Status: fixed, known_affected Remediations Vendor fix Version 5.6.0 of NetBotz 5 750/755 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware Reboot needed: Upon install, the offer will automatically restart. A customer can validate a successful install by logging into the GUI and selecting the ‘About NetBotz’ option. This will indicate the installed version. For more information see the associated Schneider Electric security advisory Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 CSAF Version, Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 PDF Version. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2026-13337 CWE-564:SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the NetBotz via the web-service interface or web-ui. View CVE Details Affected Products Schneider Electric NetBotz 5 750/755 Vendor: Schneider Electric Product Version: NetBotz 5 750 versions 5.5.2 and prior, NetBotz 5 755 Versions 5.5.2 and prior Product Status: fixed, known_affected Remediations Vendor fix Version 5.6.0 of NetBotz 5 750/755 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/61830-netbotz/#software-and-firmware Reboot needed: Upon install, the offer will automatically restart. A customer can validate a successful install by logging into the GUI and selecting the ‘About NetBotz’ option. This will indicate the installed version. For more information see the associated Schneider Electric security advisory Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 CSAF Version, Multiple Vulnerabilities on NetBotz 5 750/755 Products - SEVD-2026-223-02 PDF Version. Relevant CWE: CWE-564 SQL Injection: Hibernate Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.6 MEDIUM CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N Acknowledgments Schneider Electric CPCERT reported these vulnerabilities to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Place all controllers in locked cabinets and never leave them in the “Program” mode. Never connect programming software to any network other than the network intended for that device. Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-223-02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Original Release 2026-09-17 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-223-02 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy FACTS Control Platform (FCP)

View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product…
Read full source summary
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series Capacitor • Thyristor Controlled Series Capacitor • Static Var Compensator • Static Watt Compensator • Hybrid Synchronous Condensers Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The affected FCP versions are only applicable if GWS component is present. The following versions of Hitachi Energy FACTS Control Platform (FCP) are affected: FACTS Control Platform (FCP) 3.4.0, 3.7.0, 3.8.0, 3.10.0, 3.12.0, 3.14.0, 3.15.0, 4.0.0, 4.0.1, 4.1.0, 4.1.1 (CVE-2024-4872, CVE-2024-3980, CVE-2024-3982, CVE-2024-7940, CVE-2024-7941) CVSS Vendor Equipment Vulnerabilities v3 9.9 Hitachi Energy Hitachi Energy FACTS Control Platform (FCP) Improper Neutralization of Special Elements in Data Query Logic, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Authentication Bypass by Capture-replay, Missing Authentication for Critical Function, URL Redirection to Untrusted Site ('Open Redirect') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-4872 A vulnerability exists in the query validation of the FACTS Control system with GWS component. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-943 Improper Neutralization of Special Elements in Data Query Logic Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2024-3980 The FACTS Control system with GWS allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2024-3982 An attacker with local access to machine where FACTS Control system with GWS is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. Note: By default, the session logging level is not enabled and only users with administrator rights can enable it. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-294 Authentication Bypass by Capture-replay Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H CVE-2024-7940 The FACTS Control system with GWS product exposes a service that is intended for local only to all network interfaces without any authentication. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H CVE-2024-7941 A vulnerability exists in FACTS Control system with GWS where a HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-601 URL Redirection to Untrusted Site ('Open Redirect') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N Acknowledgments Hitachi Energy reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Additional information on Industrial Control Systems Cybersecurity Best Practices can be found in the Hitachi Energy “Industrial Control Systems Cybersecurity Best Practices” Cybersecurity Notification. [1] SSVC SSVCv2/E:N/A:N/2026-07-24T09:43:32Z/ Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000229 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-28 Date Revision Summary 2026-07-28 1 Initial public release 2026-09-17 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000229 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric GX Works3 and Motion Control Settings

View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected: Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688) Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3) vers:all/* (CVE-2026-15688) CVSS Vendor Equipment Vulnerabilities v3 8.8 Mitsubishi Electric Mitsubishi Electric GX Works3 and Motion Control Settings Incorrect Implementation of Authentication Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-15688 Incorrect Implementation of Authentication Algorithm (CWE-303) vulnerability in the affected products allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. View CVE Details Affected Products Mitsubishi Electric GX Works3 and Motion Control Settings Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric GX Works3: vers:all/*, Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3): vers:all/* Product Status: known_affected Remediations Workaround For customers using GX Works3, please download version 1.096A or later from the link https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/plceng&shiryoid=1000001411&lang=2&select=0&softid=1&infostatus=1_2_1&viewradio=0&viewstatus=&viewpos=, install it, and set the security version for projects to "2". Please refer to “15.9 Preventing Illegal Access to/Falsification of Data (Security Version)” in “GX Works3 Operating Manual” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory available at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf". Workaround For customers using Motion Control Settings (Software packaged with GX Works3), Please download version 1.070Y or later from the link "https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/ssc&shiryoid=1000000803&lang=2&select=0&softid=1&infostatus=1_8_1&viewradio=0&viewstatus=&viewpos=", install it, and set the security version for projects to "2". Please refer to “12.5 Preventing Illegal Access to/Falsification of Data (Security Version)” in “Motion Control Setting Function Help” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf". Mitigation For customers of the affected products, Mitsubishi Electric recommends using a computer with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc., to prevent unauthorized access, and allowing remote login only to trusted users when connecting a computer with the affected product to the Internet, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends preventing the user from clicking on web links contained in emails or other messages from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends installing antivirus software on a computer running the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends restricting physical access to a computer on which the affected product is installed, as well as to computers and network devices that can communicate with it, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-303 Incorrect Implementation of Authentication Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H Acknowledgments Mayeul Fargier, Erwan Cordier, Noé Flatreaud reported this vulnerability to Mitsubishi Electric. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-007 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-17 Date Revision Summary 2026-09-17 1 Initial Publication 2026-09-17 2 Initial CISA Republication of Mitsubishi Electric 2026-007 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. The following versions of Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A) are affected: Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-16 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-64 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-128 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-256 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-N32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-P32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-N32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-P32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-N32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-P32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-N32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-P32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-N32 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-P32 vers:all/* (CVE-2026-13584) Mitsubishi Electric Master/local module RJ71GN11-T2 vers:all/* (CVE-2026-13584) Mitsubishi Electric Master/local module RJ71GN11-SX vers:all/* (CVE-2026-13584) Mitsubishi Electric Master/local module RJ71GN11-EIP vers:all/* (CVE-2026-13584) Mitsubishi Electric Master/local module FX5-CCLGN-MS vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-SX vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-T2 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78G4 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78G8 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78G16 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78G64 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78GHV vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module RD78GHW vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module FX5-40SSC-G vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion module FX5-80SSC-G vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G4 vers:all/* (CVE-2026-13584) Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G16 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion Control Board MR-EM441G vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-32D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-32T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-32TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-32DT vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-32DTE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-32D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-32T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-32TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-32DT vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-32DTE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GNCF1-32D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GNCF1-32T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GNCE3-32D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GNCE3-32DT vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A4-16D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A4-16DE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A2-16T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A2-16TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A42-16DT vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN12A42-16DTE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-16D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-16T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2S1-16TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-16D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-16T vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module NZ2GN2B1-16TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D-K vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE-K vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE-K vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-14DT vers:all/* (CVE-2026-13584) Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-16DTE vers:all/* (CVE-2026-13584) Mitsubishi Electric Analog-Digital converter module NZ2GN2S-60AD4 vers:all/* (CVE-2026-13584) Mitsubishi Electric Analog-Digital converter module NZ2GN2B-60AD4 vers:all/* (CVE-2026-13584) Mitsubishi Electric Digital-Analog converter module NZ2GN2S-60DA4 vers:all/* (CVE-2026-13584) Mitsubishi Electric Digital-Analog converter module NZ2GN2B-60DA4 vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN compatible coupler NZ2FT-GN vers:all/* (CVE-2026-13584) Mitsubishi Electric FPGA module NZ2GN2S-D41P01 vers:all/* (CVE-2026-13584) Mitsubishi Electric FPGA module NZ2GN2S-D41D01 vers:all/* (CVE-2026-13584) Mitsubishi Electric FPGA module NZ2GN2S-D41PD02 vers:all/* (CVE-2026-13584) Mitsubishi Electric Tension meter LM7-1LG vers:all/* (CVE-2026-13584) Mitsubishi Electric Tension meter LM7-2LG vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5W-G vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-HS vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-RJ vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-LL vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5D-G4 vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-J5 MR-MD333G vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G vers:all/* (CVE-2026-13584) Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G4-HS vers:all/* (CVE-2026-13584) Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-4G vers:all/* (CVE-2026-13584) Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-PG vers:all/* (CVE-2026-13584) Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG vers:all/* (CVE-2026-13584) Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG-S vers:all/* (CVE-2026-13584) Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A800-GN vers:all/* (CVE-2026-13584) Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-E vers:all/* (CVE-2026-13584) Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-SCE vers:all/* (CVE-2026-13584) Mitsubishi Electric Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN expansion unit FCU8-EX569 vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL vers:all/* (CVE-2026-13584) Mitsubishi Electric Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3715-FHCBD vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3712-WXCBD vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3715-XRBA vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3715-XRBD vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3712-XRBA vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3712-XRBD vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3710-XRBA vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3710-XRBD vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3708-XRBA vers:all/* (CVE-2026-13584) Mitsubishi Electric GOT3000 Series GT3708-XRBD vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN Communication Unit GT25-J71GN13-T2 vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion Control Software SWM-G vers:all/* (CVE-2026-13584) Mitsubishi Electric Motion Control Software SWM-G-N1 vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M vers:all/* (CVE-2026-13584) Mitsubishi Electric Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M vers:all/* (CVE-2026-13584) Mitsubishi Electric Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51 vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-60 vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-300 vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-90 vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-720 vers:all/* (CVE-2026-13584) Mitsubishi Electric CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK1S-M vers:all/* (CVE-2026-13584) Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK2S-M vers:all/* (CVE-2026-13584) CVSS Vendor Equipment Vulnerabilities v3 7.1 Mitsubishi Electric Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A) Improper Enforcement of Message Integrity During Transmission in a Communication Channel Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-13584 Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CWE-924) vulnerability exists in the CC-Link IE TSN communication protocol. This vulnerability could allow an attacker with access to the same network segment to tamper with communication data, such as control input and output values, by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly. View CVE Details Affected Products Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update A) Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-16: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-64: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-128: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-R model MXR500-256: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-8-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100-16-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-8-P32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-N32: vers:all/*, Mitsubishi Electric MELSEC MX Controller MX-F model MXF100S-16-P32: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-T2: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-SX: vers:all/*, Mitsubishi Electric Master/local module RJ71GN11-EIP: vers:all/*, Mitsubishi Electric Master/local module FX5-CCLGN-MS: vers:all/*, Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-SX: vers:all/*, Mitsubishi Electric CC-Link IE TSN interface board NZ81GN11-T2: vers:all/*, Mitsubishi Electric Motion module RD78G4: vers:all/*, Mitsubishi Electric Motion module RD78G8: vers:all/*, Mitsubishi Electric Motion module RD78G16: vers:all/*, Mitsubishi Electric Motion module RD78G64: vers:all/*, Mitsubishi Electric Motion module RD78GHV: vers:all/*, Mitsubishi Electric Motion module RD78GHW: vers:all/*, Mitsubishi Electric Motion module FX5-40SSC-G: vers:all/*, Mitsubishi Electric Motion module FX5-80SSC-G: vers:all/*, Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G4: vers:all/*, Mitsubishi Electric MELSEC iQ-L Series Motion Module LD78G16: vers:all/*, Mitsubishi Electric Motion Control Board MR-EM441G: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-32DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-32DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCF1-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCF1-32T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCE3-32D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GNCE3-32DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A4-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A4-16DE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A2-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A2-16TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A42-16DT: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN12A42-16DTE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2S1-16TE: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16D: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16T: vers:all/*, Mitsubishi Electric Block-type remote module NZ2GN2B1-16TE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8D-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-8TE-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNSS2-16DTE-K: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-14DT: vers:all/*, Mitsubishi Electric Block-type remote module with safety functions NZ2GNS12A2-16DTE: vers:all/*, Mitsubishi Electric Analog-Digital converter module NZ2GN2S-60AD4: vers:all/*, Mitsubishi Electric Analog-Digital converter module NZ2GN2B-60AD4: vers:all/*, Mitsubishi Electric Digital-Analog converter module NZ2GN2S-60DA4: vers:all/*, Mitsubishi Electric Digital-Analog converter module NZ2GN2B-60DA4: vers:all/*, Mitsubishi Electric CC-Link IE TSN compatible coupler NZ2FT-GN: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41P01: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41D01: vers:all/*, Mitsubishi Electric FPGA module NZ2GN2S-D41PD02: vers:all/*, Mitsubishi Electric Tension meter LM7-1LG: vers:all/*, Mitsubishi Electric Tension meter LM7-2LG: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5W-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-HS: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-RJ: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5-G-LL: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-J5D-G4 : vers:all/*, Mitsubishi Electric AC Servo MELSERVO-J5 MR-MD333G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G: vers:all/*, Mitsubishi Electric AC Servo MELSERVO-JET MR-JET-G4-HS: vers:all/*, Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-4G: vers:all/*, Mitsubishi Electric Liner Track System MTR-S series Linear track control module MTR-SCU00-PG: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A8NCG-S: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-A800-GN: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-E: vers:all/*, Mitsubishi Electric Inverter FR-A800/F800/E800 Series FR-E800-SCE: vers:all/*, Mitsubishi Electric Industrial Robot CR800-D series controller Network Base Card 2F-DQ535-TSN: vers:all/*, Mitsubishi Electric CC-Link IE TSN expansion unit FCU8-EX569: vers:all/*, Mitsubishi Electric CC-Link IE TSN-CC-Link IE Field Network bridge module NZ2GN-GFB: vers:all/*, Mitsubishi Electric CC-Link IE TSN-AnyWireASLINK bridge module NZ2AW1GNAL: vers:all/*, Mitsubishi Electric Energy Measuring Unit CC-Link IE TSN Communication Unit EMU4-CM-TSN: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-FHCBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-WXCBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3715-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3712-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3710-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3710-XRBD: vers:all/*, Mitsubishi Electric GOT3000 Series GT3708-XRBA: vers:all/*, Mitsubishi Electric GOT3000 Series GT3708-XRBD: vers:all/*, Mitsubishi Electric CC-Link IE TSN Communication Unit GT25-J71GN13-T2: vers:all/*, Mitsubishi Electric Motion Control Software SWM-G: vers:all/*, Mitsubishi Electric Motion Control Software SWM-G-N1: vers:all/*, Mitsubishi Electric CC-Link IE TSN Communication Software for Windows SW1DND-CCIETCT-M: vers:all/*, Mitsubishi Electric Analysis Support Software MELSOFT VIMA SW1DNN-VIMA-M: vers:all/*, Mitsubishi Electric Master/Local module Designated communication LSI DeviceKit NZ2KT-NPETNG51: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-60: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP620-300: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-90: vers:all/*, Mitsubishi Electric Remote Station Communication LSI with GbE-PHY NZ2GACP621-720: vers:all/*, Mitsubishi Electric CC-Link IE TSN Master/Local module Designated communication LSI SDK SW1DNN-GN610SRC-M: vers:all/*, Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK1S-M: vers:all/*, Mitsubishi Electric Remote station software development kit SW1DNC-GNSDK2S-M: vers:all/* Product Status: known_affected Remediations No fix planned For customers using the affected products, please refer to Mitsubishi Electric's security advisory, "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf" and take the measures described there. Mitigation For customers of the affected products, Mitsubishi Electric recommends restricting physical access to the affected products and the CC-Link IE TSN network to which the affected products are connected by taking measures such as the following: (a) managing access to and from the site where the affected products are installed, (b) locking the control panel in which the affected products and/or the network devices are installed, and (c) locking the Ethernet ports such as with port lock accessories, to minimize the risk of exploitation of this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends using the affected products within a trusted network where communication with untrusted networks and hosts is blocked by a firewall or similar measures, to minimize the risk of exploitation of this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends appropriately configuring credentials and access privileges for network devices installed at the boundary between trusted networks and external networks, to minimize the risk of exploitation of this vulnerability. Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N Acknowledgments Alessandro Di Pinto, Giovanni Dini Gentilini, Luca Cremona, Gabriele Quagliarella of Nozomi Networks, Inc. reported this vulnerability to Mitsubishi Electric. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-005 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication 2026-07-30 2 CISA Republication - Initial CISA Republication of Mitsubishi Electric 2026-005 advisory 2026-09-17 3 MXF100S-N32, MXF100S-P32, MXF100S-8-N32, MXF100S-8-P32, MXF100S-16-N32, MXF100S-16-P32, LD78G4, and LD78G16 have been added as affected products and MI2532-W, MI2332-W, and NZ2GACP610-60 have been removed from affected products. 2026-09-17 4 CISA Republication update based on Mitsubishi Electric 2026-005 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-58704 Google Pixel Improper Authorization Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-58704 Google Pixel Improper Authorization Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-76460 Cisco Identity Services Engine Incorrect Use of Privileged APIs Vulnerability CVE-2026-87886 Acronis Backup Incorrect Default Permissions Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-76460 Cisco Identity Services Engine Incorrect Use of Privileged APIs Vulnerability CVE-2026-87886 Acronis Backup Incorrect Default Permissions Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Using Cyber Decoys to Strengthen Detection and Response

CISA developed this guidance to help defensive teams at varying levels of cybersecurity maturity plan and implement cyber decoy strategies that strengthen their detection and response capabilities. Many organizations struggle to detect adversaries who use legitimate credentials, native tools, and living off the land (LOTL) techniques to conduct discovery, move laterally, and access data. Cyber decoys are assets that…
Read full source summary
CISA developed this guidance to help defensive teams at varying levels of cybersecurity maturity plan and implement cyber decoy strategies that strengthen their detection and response capabilities. Many organizations struggle to detect adversaries who use legitimate credentials, native tools, and living off the land (LOTL) techniques to conduct discovery, move laterally, and access data. Cyber decoys are assets that appear to be legitimate systems, accounts, or data, but are designed to distract adversaries, detect their presence, or facilitate collection of cyber threat intelligence (CTI). As organizations adopt Zero Trust models, they should assume that a malicious threat actor may gain some level of access to their environment and plan accordingly. Cyber decoys complement Zero Trust by: Supporting continuous monitoring and verification, Creating high-fidelity alerts for suspicious activity, Reducing alert fatigue, and Helping defenders detect post-compromise activity, including adversary LOTL techniques. This guidance introduces decoy concepts—including tripwires, breadcrumbs, and honeytokens—and uses the MITRE Engage™ and MITRE ATT&CK® frameworks to provide practical, low-complexity steps for planning, implementing, and refining decoy operations. For additional information, visit CISA’s Best Practices for MITRE ATT&CK Mapping.
· CISA Cybersecurity Advisory

Schneider Electric SCADAPack x70 Products

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The following versions of Schneider Electric SCADAPack x70 Products are affected: SCADAPack 47x vers:all/* (CVE-2026-81861) SCADAPack 47xi vers:all/* (CVE-2026-81861) SCADAPack 47xd vers:all/* (CVE-2026-81861) SCADAPack 470R vers:all/* (CVE-2026-81861) SCADAPack 57x vers:all/* (CVE-2026-81861) SCADAPack 3xx vers:all/* (CVE-2026-81861) SCADAPack 32 vers:all/* (CVE-2026-81861) CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric SCADAPack x70 Products Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-81861 There is an insufficiently protected credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality. View CVE Details Affected Products Schneider Electric SCADAPack x70 Products Vendor: Schneider Electric Product Version: SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R, SCADAPack 57x, SCADAPack 3xx, SCADAPack 32 Product Status: known_affected Remediations Mitigation Implement the Role-Based Access Control (RBAC) feature and follow the SCADAPack documentation sections Security Guidelines for Administrators and Working with Role-Based Access Control. RBAC is the recommended access control mechanism for SCADAPack 47x devices and should be used in place of the Secure Lock feature. The Secure Lock feature is legacy functionality retained for backward compatibility with existing deployments and should only be used where required to support legacy system requirements. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, apply the following standard practices to reduce the risk of exploitation: Configure network segmentation to restrict access between trusted and untrusted networks. Enable and implement the RTU firewall service to restrict unauthorized access to device services and reduce the attack surface. Documentation available in RemoteConnect and SCADAPack x70 Utilities | Schneider Electric https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation Ensure setup of network segmentation to restrict access between trusted and untrusted networks and implementation of the RTU Firewall Service to restrict unauthorized access to services. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, implement all best practices referenced in the SCADAPack Cybersecurity Guide. Documentation available in RemoteConnect and SCADAPack x70 Utilities | Schneider Electric https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation For more information see the associated Schneider Electric security advisory SEVD-2026-251-03 Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products PDF Version, CSAF Version. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N Acknowledgments Abhinav Agarwal reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices: Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Place all controllers in locked cabinets and never leave them in the “Program” mode. Never connect programming software to any network other than the network intended for that device. Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-251-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-08 Date Revision Summary 2026-09-08 1 Original Release 2026-09-15 2 Initial CISA Republication of Schneider Electric SEVD-2026-251-03 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CareCam CM2507

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recover stored credentials. The following versions of CareCam CM2507 are affected: HMT.CM2507 Firmware v251211.1507 (CVE-2026-88259, CVE-2026-84398, CVE-2026-84400, CVE-2026-81305,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recover stored credentials. The following versions of CareCam CM2507 are affected: HMT.CM2507 Firmware v251211.1507 (CVE-2026-88259, CVE-2026-84398, CVE-2026-84400, CVE-2026-81305, CVE-2026-85478, CVE-2026-85497, CVE-2026-81321) CVSS Vendor Equipment Vulnerabilities v3 7.5 CareCam CareCam CM2507 Missing Authentication for Critical Function, Empty Password in Configuration File, Inclusion of Functionality from Untrusted Control Sphere, Use of Password Hash With Insufficient Computational Effort, Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-88259 CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-84398 CM2507 IP cameras accept an empty password for a privileged account exposed through its ONVIF management service. An attacker with network access to the affected device could access privileged management functions and obtain device, user, media-profile, and stream configuration information. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-258 Empty Password in Configuration File Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N CVE-2026-84400 CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.1 LOW CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N 4.0 2.3 LOW CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-81305 CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-829 Inclusion of Functionality from Untrusted Control Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-85478 A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access functionality that permits inspection or modification of boot configuration, firmware data, and software loaded by the device. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N 4.0 2.4 LOW CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-85497 CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational Effort Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-81321 CM2507 IP cameras store configured wireless network credentials in cleartext within the device filesystem. An attacker who obtains filesystem access through physical access, a debugging interface, or another vulnerability could recover the configured network identifier and pre-shared key. View CVE Details Affected Products CareCam CM2507 Vendor: CareCam Product Version: CareCam HMT.CM2507 Firmware: v251211.1507 Product Status: known_affected Remediations Mitigation CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information. Relevant CWE: CWE-312 Cleartext Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Ben Law reported these vulnerabilities to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-15 Date Revision Summary 2026-09-15 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Reyrolle 7SR5

View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647,…
Read full source summary
View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653, CVE-2026-62654) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens Reyrolle 7SR5 Integer Overflow or Wraparound, Improper Neutralization of Delimiters, Use of Out-of-range Pointer Offset, Missing Authentication for Critical Function, Insufficient Entropy, Improper Input Validation, Out-of-bounds Write, Allocation of Resources Without Limits or Throttling, Authentication Bypass Using an Alternate Path or Channel, Insertion of Sensitive Information Into Debugging Code, Download of Code Without Integrity Check Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2024-42384 Integer Overflow or Wraparound vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and produce a segmentation fault on the application. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-42385 Improper Neutralization of Delimiters vulnerability in Cesanta Mongoose Web Server v7.14 allows to trigger an out-of-bound memory write if the PEM certificate contains unexpected characters. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-140 Improper Neutralization of Delimiters Metrics CVSS Version Base Score Base Severity Vector String 3.1 4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H CVE-2024-42386 Use of Out-of-range Pointer Offset vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and produce a segmentation fault on the application. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H CVE-2024-42391 Use of Out-of-range Pointer Offset vulnerability in Cesanta Mongoose Web Server v7.14 allows an attacker to send an unexpected TLS packet and force the application to read unintended heap memory space. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N CVE-2024-42392 Improper Neutralization of Delimiters vulnerability in Cesanta Mongoose Web Server v7.14 allows to trigger an infinite loop bug if the input string contains unexpected characters. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-140 Improper Neutralization of Delimiters Metrics CVSS Version Base Score Base Severity Vector String 3.1 4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:N/A:H CVE-2026-62645 Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-62646 A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-331 Insufficient Entropy Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2026-62647 A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2026-62648 The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-62649 The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-62650 Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-288 Authentication Bypass Using an Alternate Path or Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2026-62652 The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-215 Insertion of Sensitive Information Into Debugging Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2026-62653 The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-62654 A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code. View CVE Details Affected Products Siemens Reyrolle 7SR5 Vendor: Siemens Product Version: Reyrolle 7SR5 < V2.70 Product Status: known_affected Remediations Vendor fix Update to V2.70 or later version https://support.industry.siemens.com/cs/ww/en/view/109772413/ Relevant CWE: CWE-494 Download of Code Without Integrity Check Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends protecting network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage For more information see the associated Siemens security advisory SSA-142885 in HTML and CSAF. Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-142885 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-08 Date Revision Summary 2026-09-08 1 Publication Date 2026-09-15 2 Initial CISA Republication of Siemens ProductCERT SSA-142885 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

mySCADA myPRO Manager

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing Authorization, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Czechia Vulnerabilities Expand All + CVE-2026-73807 The mySCADA myPRO Manager command API does not properly enforce authentication for privileged functions. An unauthenticated attacker with network access to the affected API could exploit this vulnerability to access privileged management functions. View CVE Details Affected Products mySCADA myPRO Manager Vendor: mySCADA Technologies Product Version: mySCADA Technologies mySCADA myPRO Manager: <=2.1 Product Status: known_affected Remediations Mitigation mySCADA Technologies has addressed these issues in Version 2.2 and recommends that users update to the latest version. Users are notified in mySCADA Pro Manager about the availability of a new version if the device is connected to the internet. Otherwise, users can download the mySCADA Pro Manager from the webpage. https://www.myscada.org/downloads/mySCADAPROManager/ Relevant CWE: CWE-862 Missing Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-82567 The myPRO Manager notification gateway exposes an unauthenticated HTTP endpoint used to send SMS messages through a connected GSM modem. The endpoint is accessible over the network and does not require authentication before accepting a phone number and message from a request and sending the specified SMS message. An unauthenticated attacker with network access to the notification gateway could exploit this vulnerability to send arbitrary SMS messages through the connected modem. View CVE Details Affected Products mySCADA myPRO Manager Vendor: mySCADA Technologies Product Version: mySCADA Technologies mySCADA myPRO Manager: <=2.1 Product Status: known_affected Remediations Mitigation mySCADA Technologies has addressed these issues in Version 2.2 and recommends that users update to the latest version. Users are notified in mySCADA Pro Manager about the availability of a new version if the device is connected to the internet. Otherwise, users can download the mySCADA Pro Manager from the webpage. https://www.myscada.org/downloads/mySCADAPROManager/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L 4.0 5.3 MEDIUM CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Shirshak Secnora OÜ reported these vulnerabilities to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-15 Date Revision Summary 2026-09-15 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Mendix SAML

View CSAF Summary Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. The following versions of Siemens Mendix SAML are affected: Mendix SAML (Mendix 10 compatible) vers:intdot/<4.2.3 (CVE-2026-80465) Mendix SAML…
Read full source summary
View CSAF Summary Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. The following versions of Siemens Mendix SAML are affected: Mendix SAML (Mendix 10 compatible) vers:intdot/<4.2.3 (CVE-2026-80465) Mendix SAML (Mendix 11 compatible) vers:intdot/<4.2.3 (CVE-2026-80465) Mendix SAML (Mendix 9.24 compatible) vers:intdot/<3.6.27 (CVE-2026-80465) CVSS Vendor Equipment Vulnerabilities v3 8.7 Siemens Siemens Mendix SAML Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-80465 Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations. View CVE Details Affected Products Siemens Mendix SAML Vendor: Siemens Product Version: Mendix SAML (Mendix 10 compatible) < V4.2.3, Mendix SAML (Mendix 11 compatible) < V4.2.3, Mendix SAML (Mendix 9.24 compatible) < V3.6.27 Product Status: known_affected Remediations Vendor fix Update to V3.6.27 or later version https://marketplace.mendix.com/link/component/1174 Vendor fix Update to V4.2.3 or later version https://marketplace.mendix.com/link/component/1174 Vendor fix Update to V4.2.3 or later version https://marketplace.mendix.com/link/component/1174 Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.7 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security, and following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories For more information see the associated Siemens security advisory SSA-887643 in HTML and CSAF. Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-887643 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-03 Date Revision Summary 2026-09-03 1 Publication Date 2026-09-15 2 Initial CISA Republication of Siemens ProductCERT SSA-887643 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Wärtsilä FOS-Onboard

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client. The following versions of Wärtsilä FOS-Onboard are affected: FOS-Onboard 5.07.0923.01 (CVE-2026-78225, CVE-2026-81855) CVSS Vendor Equipment Vulnerabilities v3 9.1 Wärtsilä Wärtsilä FOS-Onboard Use…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client. The following versions of Wärtsilä FOS-Onboard are affected: FOS-Onboard 5.07.0923.01 (CVE-2026-78225, CVE-2026-81855) CVSS Vendor Equipment Vulnerabilities v3 9.1 Wärtsilä Wärtsilä FOS-Onboard Use of Hard-coded Cryptographic Key Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-78225 A hardcoded cryptographic server key vulnerability exists in the deployer-ng Update Controller component of Wärtsilä FOS-Onboard. View CVE Details Affected Products Wärtsilä FOS-Onboard Vendor: Wärtsilä Product Version: Wärtsilä FOS-Onboard: 5.07.0923.01 Product Status: known_affected Remediations Mitigation Wärtsilä states that the vulnerabilities are not exploitable when the product is installed as recommended, and has developed a security patch. Users are also directed to contact Wärtsilä to obtain and install the patch. To obtain and install the latest patch, contact Wärtsilä: https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 9.5 CRITICAL CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H CVE-2026-81855 A hardcoded cryptographic client authentication key vulnerability exists in the robot testing framework component of Wärtsilä FOS-Onboard. View CVE Details Affected Products Wärtsilä FOS-Onboard Vendor: Wärtsilä Product Version: Wärtsilä FOS-Onboard: 5.07.0923.01 Product Status: known_affected Remediations Mitigation Wärtsilä states that the vulnerabilities are not exploitable when the product is installed as recommended, and has developed a security patch. Users are also directed to contact Wärtsilä to obtain and install the patch. To obtain and install the latest patch, contact Wärtsilä: https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-ics-patch-deployment#contact Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Cydome Security Ltd reported these vulnerabilities to Wärtsilä and CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-15 Date Revision Summary 2026-09-15 1 Initial Publication Legal Notice and Terms of Use
Browse saved snapshots