CISA Advisories records

Source published · CISA Cybersecurity Advisory

CISA Releases Two Industrial Control Systems Advisories

CISA released two Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-364-01: WHILL C2 Wheelchairs ICSA-25-345-03: AzeoTech DAQFactory (Update A) CISA encourages users and administrators to review newly released ICS Advisories for technical details and mitigations.
Source published · CISA Cybersecurity Advisory

WHILL Model C2 Electric Wheelchairs and Model F Power Chairs

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to take control over the product. The following versions of WHILL Model C2 Electric Wheelchairs and Model F Power Chairs are affected: Model C2 Electric WheelChair (CVE-2025-14346) Model F Power Chair (CVE-2025-14346) CVSS Vendor Equipment Vulnerabilities v3 9.8 WHILL Inc. WHILL Model C2 Electric…
Read more of the source summary
Wheelchairs and Model F Power Chairs Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-14346 WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. View CVE Details Affected Products WHILL Model C2 Electric Wheelchairs and Model F Power Chairs Vendor: WHILL Inc. Product Version: WHILL Inc. Model C2 Electric WheelChair: vers:all/*, WHILL Inc. Model F Power…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14847 MongoDB and MongoDB Server Improper Handling of Length Parameter Inconsistency Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD)…
Read more of the source summary
22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified…
Source published · CISA Cybersecurity Advisory

CISA Releases One Industrial Control Systems Advisory

CISA released one Industrial Control Systems (ICS) Advisory. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-177-01 Mitsubishi Electric Air Conditioning Systems (Update B) CISA encourages users and administrators to review the newly released ICS advisory for technical details and mitigations.
Source published · CISA Cybersecurity Advisory

NIST and CISA Release Draft Interagency Report on Protecting Tokens and Assertions from Tampering Theft and Misuse for Public Comment

The Cybersecurity and Infrastructure Security Agency (CISA) and National Institute of Standards and Technology (NIST) have released an initial draft of Interagency Report (IR) 8597 Protecting Tokens and Assertions from Forgery, Theft, and Misuse for public comment through January 30, 2026. This report is in response to Sustaining Select Efforts to Strengthen the Nation’s Cybersecurity and Amending Executive Order…
Read more of the source summary
13694 and Executive Order 14144, providing implementation guidance to help federal agencies and cloud service providers (CSPs) protect identity tokens and assertions from forgery, theft, and misuse. Recent cybersecurity incidents at major cloud service providers have focused on stealing, modifying, or forging identity tokens and assertions to gain access to protected resources. This report covers the controls for identity access management (IAM) systems that rely on digitally signed assertions and tokens when making access decisions. It discusses how CSPs and cloud consumers, including government agencies, can better define their respective roles and responsibilities for managing IAM controls in cloud environments. It establishes principles for both CSPs and cloud…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-52163 Digiever DS-2105 Pro Missing Authorization Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read more of the source summary
Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

CISA and Partners Release Update to Malware Analysis Report BRICKSTORM Backdoor

Today, the Cybersecurity and Infrastructure Security Agency (CISA), National Security Agency, and Canadian Centre for Cyber Security released an update to the Malware Analysis Report BRICKSTORM Backdoor with indicators of compromise (IOCs) and detection signatures for additional BRICKSTORM samples. This update provides information on additional samples, including Rust-based samples. These samples demonstrate…
Read more of the source summary
advanced persistence and defense evasion mechanisms, such as running as background services, and enhanced command and control capabilities through encrypted WebSocket connections. The update includes two new detection signatures in the form of YARA rules, enabling organizations to better identify BRICKSTORM-related activity. Organizations are strongly encouraged to deploy these updated IOCs and signatures, and to follow the detection guidance to scan for and respond to BRICKSTORM infections If BRICKSTORM, similar malware, or potentially related activity is detected, report the incident to CISA’s 24/7 Operations Center at contact@cisa.dhs.gov or (888) 282-0870.
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-14733 WatchGuard Firebox Out-of-Bounds Write Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read more of the source summary
Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Siemens Interniche IP-Stack

View CSAF Summary Multiple Industrial products are affected by a vulnerability in the Interniche IP-Stack. The affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an…
Read more of the source summary
attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Interniche IP-Stack are affected: SIDOOR ATD430W (CVE-2025-40820) SIDOOR ATE530G COATED (6FB1221-5SM10-7BP0) (CVE-2025-40820) SIDOOR ATE530S COATED (CVE-2025-40820) SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) (CVE-2025-40820) SIMATIC CFU PA (6ES7655-5PX11-0XX0) (CVE-2025-40820) SIMATIC CFU PA (6ES7655-5PX11-1XX0) (CVE-2025-40820) SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)…
Source published · CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Foxboro DCS Advisor

View CSAF Summary Schneider Electric is aware of a vulnerability disclosed by Microsoft in the Microsoft Windows Server Update Services (WSUS) used in the EcoStruxure™ Foxboro DCS Advisor services. The EcoStruxure™ Foxboro DCS Advisor, an optional component of the [EcoStruxure™ Foxboro DCS system](https://www.se.com/ww/en/work/products/industrial-automation-control/foxboro-dcs/), facilitates remote connectivity and…
Read more of the source summary
diagnostics by continuously monitoring key performance indicators (KPI) on the I/A Series or Control Software system's process. Failure to apply the remediations provided below may risk a potential remote code execution event, which could result in system-level privileges acquired by unauthorized parties. The following versions of Schneider Electric EcoStruxure Foxboro DCS Advisor are affected: EcoStruxure™ Foxboro DCS Advisor services () CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric EcoStruxure Foxboro DCS Advisor Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All +…
Source published · CISA Cybersecurity Advisory

Inductive Automation Ignition

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to be granted direct SYSTEM-level code execution on the host operating system running the Ignition Gateway service on Windows systems. The following versions of Inductive Automation Ignition are affected: Ignition (CVE-2025-13911) CVSS Vendor Equipment Vulnerabilities v3 6.4 Inductive Automation Inductive Automation Ignition…
Read more of the source summary
Execution with Unnecessary Privileges Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13911 The vulnerability affects Ignition SCADA applications where Python scripting is utilized for automation purposes. The vulnerability arises from the absence of proper security controls that restrict which Python libraries can be imported and executed within the scripting environment. The core issue lies in the Ignition service account having system permissions beyond what an Ignition privileged user requires. When an authenticated administrator uploads a malicious project file containing Python scripts with bind shell…
Source published · CISA Cybersecurity Advisory

Advantech WebAccess/SCADA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an authenticated attacker to read or modify a remote database. The following versions of Advantech WebAccess/SCADA are affected: WebAccess/SCADA (CVE-2025-14850, CVE-2025-14849, CVE-2025-14848, CVE-2025-46268, CVE-2025-67653) CVSS Vendor Equipment Vulnerabilities v3 8.8 Advantech Advantech WebAccess/SCADA Improper Limitation of a Pathname…
Read more of the source summary
to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type, Absolute Path Traversal, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan, Province of China Vulnerabilities Expand All + CVE-2025-14850 The affected product is vulnerable to directory traversal, which may allow an attacker to delete arbitrary files. View CVE Details Affected Products Advantech WebAccess/SCADA Vendor: Advantech Product Version: Advantech WebAccess/SCADA: 9.2.1 Product Status: known_affected Remediations Vendor fix Advantech recommends users apply the…
Source published · CISA Cybersecurity Advisory

National Instruments LabView

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code. The following versions of National Instruments LabView are affected: LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462,…
Read more of the source summary
CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) CVSS Vendor Equipment Vulnerabilities v3 7.8 National Instruments National Instruments LabView Out-of-bounds Write, Out-of-bounds Read, Use After Free, Stack-based Buffer Overflow Background Critical Infrastructure…
Source published · CISA Cybersecurity Advisory

CISA Releases Nine Industrial Control Systems Advisories

CISA released nine Industrial Control Systems (ICS) Advisories. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-352-01 Inductive Automation Ignition ICSA-25-352-02 Schneider Electric EcoStruxure Foxboro DCS Advisor ICSA-25-352-03 National Instruments LabView ICSA-25-352-04 Mitsubishi Electric Iconics Digital Solutions and Mitsubishi…
Read more of the source summary
Electrics Products ICSA-25-352-05 Siemens Interniche IP-Stack ICSA-25-352-06 Advantech WebAccess/SCADA ICSA-25-352-07 Rockwell Automation Micro820, Micro850, Micro 870 ICSA-25-352-08 Axis Communications Camera Station Pro, Camera Station, and Device Manager ICSA-24-291-03 Mitsubishi Electric CNC Series (Update C) CISA encourages users and administrators to review newly released ICS Advisories for technical details and mitigations.
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electrics Products

View CSAF Summary Successful exploitation of this vulnerability could result in denial-of-service (DoS), information tampering, and information disclosure. The following versions of Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electrics Products are affected: GENESIS64 (CVE-2025-11774) ICONICS Suite (CVE-2025-11774) MobileHMI (CVE-2025-11774) MC Works64 (CVE-2025-11774) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 8.2 Mitsubishi Electric Iconics Digital Solutions, Mitsubishi Electric Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electrics Products Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan, United States Vulnerabilities Expand All + CVE-2025-11774 Malicious code execution vulnerability exists in the software keyboard function (hereinafter referred to as "keypad function") of ICONICS Suite, GENESIS64, MobileHMI, and MC Works64, which could lead to denial-of-service (DoS), information tampering, and information disclosure. An attacker may be able to execute arbitrary…
Source published · CISA Cybersecurity Advisory

Axis Communications Camera Station Pro, Camera Station, and Device Manager

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker executing arbitrary code, executing a man-in-middle style attack, or bypass authentication. The following versions of Axis Communications Camera Station Pro, Camera Station, and Device Manager are affected: AXIS Camera Station Pro (CVE-2025-30023, CVE-2025-30025, CVE-2025-30026) AXIS Camera Station (CVE-2025-30023,…
Read more of the source summary
CVE-2025-30025, CVE-2025-30026) AXIS Device Manager (CVE-2025-30023, CVE-2025-30024, CVE-2025-30025) CVSS Vendor Equipment Vulnerabilities v3 9 Axis Communications Axis Communications Camera Station Pro, Camera Station, and Device Manager Deserialization of Untrusted Data, Improper Certificate Validation, Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2025-30023 The communication protocol used between client and server had a flaw that could lead to an authenticated user performing a remote code execution attack. View CVE Details Affected Products Axis Communications Camera…
Source published · CISA Cybersecurity Advisory

Rockwell Automation Micro820, Micro850, Micro870

View CSAF Summary Successful exploitation of these vulnerabilities could result in a denial-of-service condition. The following versions of Rockwell Automation Micro820, Micro850, Micro870 are affected: Micro820 (CVE-2025-13823, CVE-2025-13824) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Micro820, Micro850, Micro870 Dependency on Vulnerable Third-Party Component, Release of…
Read more of the source summary
Invalid Pointer or Reference Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13823 A security issue was found in the IPv6 stack in the Micro850 and Micro870 controllers. This issue occurs when the controllers received multiple malformed packets during fuzzing, causing a recoverable fault. View CVE Details Affected Products Rockwell Automation Micro820, Micro850, Micro870 Vendor: Rockwell Automation Product Version: Rockwell Automation Micro820: <=V14.011 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users of Micro820 V14.011 and prior update to newer Micro820 controllers (L20E V23.011 or later).…
Source published · CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-20393 Cisco Multiple Products Improper Input Validation Vulnerability CVE-2025-40602 SonicWall SMA1000 Missing Authorization Vulnerability CVE-2025-59374 ASUS Live Update Embedded Malicious Code Vulnerability These types of vulnerabilities are frequent attack vectors for…
Read more of the source summary
malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-59718 Fortinet Multiple Products Improper Verification of Cryptographic Signature Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01:…
Read more of the source summary
Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Güralp Systems Fortimus Series, Minimus Series, and Certimus Series

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Güralp Systems Fortimus Series, Minimus Series, and Certimus Series are affected: Fortimus Series (CVE-2025-14466) Minimus Series (CVE-2025-14466) Certimus Series (CVE-2025-14466) CVSS Vendor Equipment Vulnerabilities v3 5.3 Güralp Systems Güralp Systems Fortimus…
Read more of the source summary
Series, Minimus Series, and Certimus Series Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-14466 A vulnerability in the web interface of the Güralp Fortimus Series, Minimus Series and Certimus Series allows an unauthenticated attacker with network access to send specially-crafted HTTP requests that can cause the web service process to deliberately restart. Although this mechanism limits the impact of the attack, it results in a brief denial-of-service condition during the restart. View CVE Details Affected Products Güralp Systems Fortimus Series, Minimus Series, and Certimus Series…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing