National Instruments LabView
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code. The following versions of National Instruments LabView are affected: LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code. The following versions of National Instruments LabView are affected: LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) LabVIEW (CVE-2025-64461, CVE-2025-64462, CVE-2025-64463, CVE-2025-64464, CVE-2025-64465, CVE-2025-64466, CVE-2025-64467, CVE-2025-64468, CVE-2025-64469) CVSS Vendor Equipment Vulnerabilities v3 7.8 National Instruments National Instruments LabView Out-of-bounds Write, Out-of-bounds Read, Use After Free, Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing, Defense Industrial Base, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-64461 LabVIEW is vulnerable to an out-of-bounds write vulnerability when opening a corrupted VI, which may allow an attacker to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64462 LabVIEW is vulnerable to an out-of-bounds read vulnerability in LVResFile::RGetMemFileHandle() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64463 LabVIEW is vulnerable to an out-of-bounds read vulnerability in LVResource::DetachResource() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64464 LabVIEW is vulnerable to an out-of-bounds read vulnerability in lvre!VisaWriteFromFile() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64465 LabVIEW is vulnerable to an out-of-bounds read vulnerability in lvre!DataSizeTDR() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64466 LabVIEW is vulnerable to an out-of-bounds read vulnerability in lvre!ExecPostedProcRecPost() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64467 LabVIEW is vulnerable to an out-of-bounds read vulnerability in LVResFile::FindRsrcListEntry() when opening a corrupted VI, which may allow an attacker to disclose information or to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64468 LabVIEW is vulnerable to a use-after-free vulnerability when opening a corrupted VI, which may allow an attacker to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-64469 LabVIEW is vulnerable to a stack-based buffer overflow vulnerability when opening a corrupted VI, which may allow an attacker to execute arbitrary code. Successful exploitation requires an attacker to get a user to open a specially crafted VI file. View CVE Details Affected Products National Instruments LabView Vendor: National Instruments Product Version: National Instruments LabVIEW: <=2025_Q3, National Instruments LabVIEW: 2024, National Instruments LabVIEW: 2023, National Instruments LabVIEW: 2022, National Instruments LabVIEW: 2021 Product Status: known_affected Remediations Mitigation National Instruments recommends users apply the following mitigations to help reduce the risk: Vendor fix LabVIEW 2025: Upgrade to LabVIEW 2025 Q3 Patch 3 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2024: Upgrade to LabVIEW 2024 Q3 Patch 5 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2023: Upgrade to LabVIEW 2023 Q3 Patch 8 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2022: Upgrade to LabVIEW 2022 Q3 Patch 7 or later from NI Package Manager or Software Downloads Vendor fix LabVIEW 2021: Not in Mainstream Support Mitigation For more information refer to National Instruments security advisory. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Acknowledgments Michael Heinzl reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2025-12-18 Date Revision Summary 2025-12-18 1 Initial Publication Legal Notice and Terms of Use