· CISA Cybersecurity Advisory

Siemens SIMATIC and SIPLUS products

View CSAF Summary Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends…
Read full source summary
View CSAF Summary Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC and SIPLUS products are affected: SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (CVE-2025-40944) SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (CVE-2025-40944) SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (CVE-2025-40944) SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (CVE-2025-40944) SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (CVE-2025-40944) SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (CVE-2025-40944) SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (CVE-2025-40944) SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (CVE-2025-40944) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens SIMATIC and SIPLUS products Uncontrolled Resource Consumption Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40944 Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation. View CVE Details Affected Products Siemens SIMATIC and SIPLUS products Vendor: Siemens Product Version: SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) Product Status: known_affected Remediations Mitigation Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk: All affected products: Filter the port 102 of the devices to only accepted connections to/from the IP addresses of machines that are trusted e.g. with an external firewall. All affected products: Restrict access to the network where S7 communication messages are exchanged. SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0): Currently no fix is planned SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): Update to V1.3 SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0): Update to V4.2.2 SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0): Update to V6.0.0 SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0): Update to V6.0.1 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-674753 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Publication Date 2026-01-14 2 Initial Republication of Siemens ProductCERT SSA-674753 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Industrial Edge Device Kit

View CSAF Summary Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new…
Read full source summary
View CSAF Summary Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Industrial Edge Device Kit are affected: Industrial Edge Device Kit - arm64 V1.10 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.11 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.12 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.13 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.14 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.15 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.16 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.17 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.18 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.19 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.20 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.21 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.22 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.23 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.24 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.25 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.5 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.6 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.7 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.8 (CVE-2025-40805) Industrial Edge Device Kit - arm64 V1.9 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.10 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.11 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.12 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.13 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.14 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.15 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.16 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.17 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.18 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.19 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.20 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.21 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.22 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.23 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.24 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.25 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.5 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.6 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.7 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.8 (CVE-2025-40805) Industrial Edge Device Kit - x86-64 V1.9 (CVE-2025-40805) CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens Industrial Edge Device Kit Authorization Bypass Through User-Controlled Key Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40805 Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user. View CVE Details Affected Products Siemens Industrial Edge Device Kit Vendor: Siemens Product Version: Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9 Product Status: known_affected Remediations Mitigation Siemens has released new versions for several affected products and advises updating to the latest versions. Siemens recommends specific countermeasures for products where fixes are unavailable or not yet released. * Ensure network access to affected products is limited to trusted parties only * Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - x86-64 V1.24: Update to V1.24.2 or later version * Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - x86-64 V1.25: Update to V1.25.1 or later version Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-014678 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Publication Date 2026-01-14 2 Initial Republication of Siemens ProductCERT SSA-014678 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808…
Read full source summary
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 (CVE-2025-40891, CVE-2025-40892, CVE-2025-40893, CVE-2025-40898) CVSS Vendor Equipment Vulnerabilities v3 8.9 Siemens Siemens RUGGEDCOM APE1808 Devices Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40891 A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.7 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N CVE-2025-40892 A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.9 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:H CVE-2025-40893 A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N CVE-2025-40898 A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability. View CVE Details Affected Products Siemens RUGGEDCOM APE1808 Devices Vendor: Siemens Product Version: RUGGEDCOM APE1808 Product Status: known_affected Remediations Vendor fix Contact customer support to receive patch and update information Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-827968 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Publication Date 2026-01-14 2 Initial Republication of Siemens ProductCERT SSA-827968 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens SINEC Security Monitor

View CSAF Summary SINEC Security Monitor before V4.10.0 contains multiple vulnerabilities. Siemens has released a new version for SINEC Security Monitor and recommends to update to the latest version. The following versions of Siemens SINEC Security Monitor are affected: SINEC Security Monitor (CVE-2025-40830, CVE-2025-40831) CVSS Vendor Equipment Vulnerabilities v3 6.7 Siemens Siemens SINEC Security Monitor…
Read full source summary
View CSAF Summary SINEC Security Monitor before V4.10.0 contains multiple vulnerabilities. Siemens has released a new version for SINEC Security Monitor and recommends to update to the latest version. The following versions of Siemens SINEC Security Monitor are affected: SINEC Security Monitor (CVE-2025-40830, CVE-2025-40831) CVSS Vendor Equipment Vulnerabilities v3 6.7 Siemens Siemens SINEC Security Monitor Improper Authorization, Improper Input Validation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40830 The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. View CVE Details Affected Products Siemens SINEC Security Monitor Vendor: Siemens Product Version: SINEC Security Monitor Product Status: known_affected Remediations Vendor fix Update to V4.10.0 or later version Relevant CWE: CWE-285 Improper Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H CVE-2025-40831 The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality. View CVE Details Affected Products Siemens SINEC Security Monitor Vendor: Siemens Product Version: SINEC Security Monitor Product Status: known_affected Remediations Vendor fix Update to V4.10.0 or later version Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-882673 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-12-09 Date Revision Summary 2025-12-09 1 Publication Date 2026-01-14 2 Initial Republication of Siemens ProductCERT SSA-882673 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20805 Microsoft Windows Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20805 Microsoft Windows Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk DataMosaix Private Cloud

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform unauthorized sensitive database operations. The following versions of Rockwell Automation FactoryTalk DataMosaix Private Cloud are affected: FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform unauthorized sensitive database operations. The following versions of Rockwell Automation FactoryTalk DataMosaix Private Cloud are affected: FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) FactoryTalk DataMosaix Private Cloud (CVE-2025-12807) CVSS Vendor Equipment Vulnerabilities v3 8.8 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Private Cloud Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-12807 A security issue was discovered in DataMosaix Private Cloud, allowing users with low privilege to perform sensitive database operations through exposed Application Programming Interface (API) endpoints. View CVE Details Affected Products Rockwell Automation FactoryTalk DataMosaix Private Cloud Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk DataMosaix Private Cloud: 7.11, Rockwell Automation FactoryTalk DataMosaix Private Cloud: 8.00, Rockwell Automation FactoryTalk DataMosaix Private Cloud: 8.01 Product Status: known_affected Remediations Mitigation Rockwell Automation encourages users of the affected software to apply the following risk mitigations, if possible: Vendor fix Update FactoryTalk DataMosaix Private Cloud to Version 8.01.02 or later. Mitigation Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's best security practices. Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Initial republication of Rockwell Automation advisory 'FactoryTalk DataMosaix Private Cloud SQL Injection' Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation 432ES-IG3 Series A

View CSAF Summary Successful exploitation of this vulnerability could result in a denial-of-service condition. The following versions of Rockwell Automation 432ES-IG3 Series A are affected: 432ES-IG3 Series A (CVE-2025-9368) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 432ES-IG3 Series A Allocation of Resources Without Limits or Throttling Background Critical Infrastructure…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in a denial-of-service condition. The following versions of Rockwell Automation 432ES-IG3 Series A are affected: 432ES-IG3 Series A (CVE-2025-9368) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 432ES-IG3 Series A Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-9368 A security issue exists within 432ES-IG3 Series A, which affects GuardLink EtherNet/IP Interface, resulting in a denial-of-service condition. A manual power cycle is required to recover the device. View CVE Details Affected Products Rockwell Automation 432ES-IG3 Series A Vendor: Rockwell Automation Product Version: Rockwell Automation 432ES-IG3 Series A: V1.001 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users of 432ES-IG3 Series A update to V2.001.9 or later. The upgrade can be downloaded from the Rockwell Automation website. Mitigation Rockwell Automation users using the affected software, who are not able to upgrade to one of the corrected versions, should follow Rockwell Automation's security best practices. Mitigation For more information, please review Rockwell Automation's advisory. Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Initial Republication of Rockwell Automation advisory SD1764 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

YoSmart YoLink Smart Hub

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely control other users' smart home devices, intercept sensitive data, and hijack sessions. The following versions of YoSmart YoLink Smart Hub are affected: YoSmart server (CVE-2025-59449, CVE-2025-59451) YoLink Smart Hub (CVE-2025-59452) YoLink Mobile Appication (CVE-2025-59448) CVSS Vendor Equipment Vulnerabilities…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely control other users' smart home devices, intercept sensitive data, and hijack sessions. The following versions of YoSmart YoLink Smart Hub are affected: YoSmart server (CVE-2025-59449, CVE-2025-59451) YoLink Smart Hub (CVE-2025-59452) YoLink Mobile Appication (CVE-2025-59448) CVSS Vendor Equipment Vulnerabilities v3 5.8 YoSmart YoSmart YoLink Smart Hub Incorrect Authorization, Generation of Predictable Numbers or Identifiers, Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-59449 The YoSmart YoLink MQTT broker through 2025-10-02 does not enforce sufficient authorization controls to prevent cross-account attacks, allowing an attacker to remotely operate affected devices if the attacker obtains the associated device IDs. Because YoLink device IDs are predictable, an attacker can exploit this to gain full control over any other YoLink user's devices. View CVE Details Affected Products YoSmart YoLink Smart Hub Vendor: YoSmart Product Version: YoSmart server: vers:all/* Product Status: known_affected Remediations Mitigation YoSmart recommends that users take the following actions to mitigate these vulnerabilities: Mitigation CVE-2025-59449 & CVE-2025-59451 - YoSmart's engineering team resolved these vulnerabilities on the server backend. No user actions are required Mitigation For more information visit the YoSmart Security Advisory. Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N CVE-2025-59452 The YoSmart YoLink API through 2025-10-02 uses an endpoint URL that is derived from a device's MAC address along with an MD5 hash of non-secret information, such as a key that begins with cf50. View CVE Details Affected Products YoSmart YoLink Smart Hub Vendor: YoSmart Product Version: YoSmart YoLink Smart Hub: 0382 Product Status: known_affected Remediations Mitigation YoSmart recommends that users take the following actions to mitigate these vulnerabilities: Mitigation CVE-2025-59452 - YoSmart released update 0383 to support a new, dynamic authentication algorithm. This will be released as an automatic over-the-air update and no user action is required. Mitigation For more information visit the YoSmart Security Advisory. Relevant CWE: CWE-340 Generation of Predictable Numbers or Identifiers Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N CVE-2025-59448 Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Mobile Application 1.40.41 and YoLink MQTT Broker. View CVE Details Affected Products YoSmart YoLink Smart Hub Vendor: YoSmart Product Version: YoSmart YoLink Mobile Appication: <v1.40.45 Product Status: known_affected Remediations Mitigation YoSmart recommends that users take the following actions to mitigate these vulnerabilities: Mitigation CVE-2025-59448 - YoSmart recommends that users update to version 1.40.45 or later to mitigate this vulnerability. Mitigation For more information visit the YoSmart Security Advisory. Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.7 MEDIUM CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N CVE-2025-59451 The YoSmart YoLink application through 2025-10-02 has session tokens with unexpectedly long lifetimes. View CVE Details Affected Products YoSmart YoLink Smart Hub Vendor: YoSmart Product Version: YoSmart server: vers:all/* Product Status: known_affected Remediations Mitigation YoSmart recommends that users take the following actions to mitigate these vulnerabilities: Mitigation CVE-2025-59449 & CVE-2025-59451 - YoSmart's engineering team resolved these vulnerabilities on the server backend. No user actions are required Mitigation For more information visit the YoSmart Security Advisory. Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:L/A:N Acknowledgments Nick Cerne of Bishop Fox reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-01-13 Date Revision Summary 2026-01-13 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-8110 Gogs Path Traversal Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-8110 Gogs Path Traversal Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Hitachi Energy Asset Suite

View CSAF Summary Hitachi Energy is aware of a Jasper Report vulnerability that affects the Asset Suite product versions mentioned in this document below. This vulnerability can be exploited to carry out remote code execution (RCE) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Asset Suite are…
Read full source summary
View CSAF Summary Hitachi Energy is aware of a Jasper Report vulnerability that affects the Asset Suite product versions mentioned in this document below. This vulnerability can be exploited to carry out remote code execution (RCE) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Asset Suite are affected: Asset Suite (CVE-2025-10492) CVSS Vendor Equipment Vulnerabilities v3 9.8 Hitachi Energy Hitachi Energy Asset Suite Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-10492 A vulnerability exists in Jasper Report third party component of Asset Suite. A Java deserialization vulnerability has been discovered in Jaspersoft Library. Improper handling of externally supplied data may allow attackers to execute arbitrary code remotely on systems that use the affected library. View CVE Details Affected Products Hitachi Energy Asset Suite Vendor: Hitachi Energy Product Version: Asset Suite versions 9.7 and prior Product Status: known_affected Remediations Vendor fix Update to version 9.8 Mitigation Restrict the loading of external custom reports created by end users by allowing only trusted Jasper reports generated by the system administrator Mitigation Apply general mitigation factors Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Hitachi Energy PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000231 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-12-09 Date Revision Summary 2025-12-09 1 Initial public release 2026-01-08 2 Initial Republication of Hitachi Energy PSIRT 8DBD000231 advisory Legal Notice and Terms of Use