Cybersecurity

CISA Advisories snapshot, Feb 13, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records

Source published · CISA Cybersecurity Advisory

Siemens SINEC NMS

View CSAF Summary Multiple Siemens products are affected by two local privilege escalation vulnerabilities which could allow an low privileged attacker to load malicious DLLs, potentially leading to arbitrary code execution with elevated privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SINEC NMS are affected:…
Read more of the source summary
SINEC NMS: Versions prior to V4.0 SP2 (CVE-2026-25655) SINEC NMS: All Versions (CVE-2026-25656) User Management Component (UMC) vers:intdot/<2.15.2.1 (CVE-2026-25656) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens SINEC NMS Uncontrolled Search Path Element Background Critical Infrastructure Sectors: Information Technology, Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25655 The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with administrative privilege.(ZDI-CAN-28107) View CVE Details Affected Products…
Source published · CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-43468 Microsoft Configuration Manager SQL Injection Vulnerability CVE-2025-15556 Notepad++ Download of Code Without Integrity Check Vulnerability CVE-2025-40536 SolarWinds Web Help Desk Security Control Bypass Vulnerability CVE-2026-20700 Apple Multiple Buffer Overflow…
Read more of the source summary
Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing…
Source published · CISA Cybersecurity Advisory

Siemens Siveillance Video Management Servers

View CSAF Summary The Webhooks implementation of Siveillance Video Management Servers contains a vulnerability that could allow an authenticated remote attacker with read-only privileges to achieve full access to Webhooks API. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video Management Servers are…
Read more of the source summary
affected: Siveillance Video V2023 R1: All versions < V23.1 HotfixRev18 Siveillance Video V2023 R2: All versions < V23.2 HotfixRev18 Siveillance Video V2023 R3: All versions < V23.3 HotfixRev23 Siveillance Video V2024 R1: All versions < V24.1 HotfixRev14 Siveillance Video V2025: All versions < V25.1 HotfixRev8 CVSS Vendor Equipment Vulnerabilities v3 6.3 Siemens Siemens Siveillance Video Management Servers Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-0836 Missing Authorization vulnerability in Milestone Systems XProtect VMS allows users with read-only access to Management Server to have full read/write access to MIP Webhooks…
Source published · CISA Cybersecurity Advisory

Siemens Solid Edge

View CSAF Summary Solid Edge uses PS/IGES Parasolid Translator Component that contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Solid Edge and…
Read more of the source summary
recommends to update to the latest version. The following versions of Siemens Solid Edge are affected: Solid Edge: All versions prior to V226.00 Update 03 CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40936 The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755) View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge Product Status:…
Source published · CISA Cybersecurity Advisory

Siemens Polarion

View CSAF Summary Polarion before V2506 contains a vulnerability that could allow authenticated remote attackers to conduct cross-site scripting attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Polarion are affected: Polarion V2404 vers:intdot/<2404.5 (CVE-2025-40587) Polarion V2410 vers:intdot/<2410.2…
Read more of the source summary
(CVE-2025-40587) CVSS Vendor Equipment Vulnerabilities v3 7.6 Siemens Siemens Polarion Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40587 The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application. View CVE Details Affected Products Siemens Polarion Vendor: Siemens Product Version: Polarion V2404, Polarion V2410 Product Status:…
Source published · CISA Cybersecurity Advisory

Airleader Master

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to obtain remote code execution. The following versions of Airleader Master are affected: Airleader Master <=6.381 (CVE-2026-1358) CVSS Vendor Equipment Vulnerabilities v3 9.8 Airleader GmbH Airleader Master Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Chemical, Critical…
Read more of the source summary
Manufacturing, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-1358 Airleader Master versions 6.381 and prior allow for file uploads without restriction to multiple webpages running maximum privileges. This could allow an unauthenticated user to potentially obtain remote code execution on the server. View CVE Details Affected Products Airleader Master Vendor: Airleader GmbH Product Version: Airleader GmbH Airleader Master: <=6.381 Product Status: known_affected Remediations Vendor fix Airleader recommends that users upgrade Airleader Master to version 6.386 or later. Mitigation Users of Airleader Master are…
Source published · CISA Cybersecurity Advisory

Siemens NX

View CSAF Summary Siemens NX is affected by multiple file parsing vulnerabilities that could be triggered when the application reads files in CGM format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for NX and recommends to update to the latest version. The…
Read more of the source summary
following versions of Siemens NX are affected: NX vers:intdot/<2512 (CVE-2026-22923, CVE-2026-22924, CVE-2026-22925) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens NX Stack-based Buffer Overflow, Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-22923 The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens NX Vendor: Siemens Product Version: NX Product Status: known_affected Remediations Mitigation…
Source published · CISA Cybersecurity Advisory

Siemens Desigo CC Product Family and SENTRON Powermanager

View CSAF Summary Versions V6.0 through V8 QU1 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could lead to code execution in the context of the current process.…
Read more of the source summary
Siemens has released instructions how to update the CodeMeter Runtime component and recommends to apply the update on affected systems. The following versions of Siemens Desigo CC Product Family and SENTRON Powermanager are affected: Desigo CC family V6 vers:all/* (CVE-2023-38545) Desigo CC family V7 vers:all/* (CVE-2023-38545) Desigo CC family V8: All versions prior to V8.0 QU2 SENTRON Powermanager V6 vers:all/* (CVE-2023-38545) SENTRON Powermanager V7 vers:all/* (CVE-2023-38545) SENTRON Powermanager V8: All versions prior to V8.0 QU2 CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens Desigo CC Product Family and SENTRON Powermanager Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide…
Source published · CISA Cybersecurity Advisory

Siemens SINEC OS

View CSAF Summary SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SINEC OS are affected: RUGGEDCOM RST2428P (6GK6242-6PA00) vers:intdot/<3.3 (CVE-2022-48174, CVE-2023-7256, CVE-2023-39810, CVE-2023-42363, CVE-2023-42364, CVE-2023-42365,…
Read more of the source summary
CVE-2023-42366, CVE-2024-6197, CVE-2024-6874, CVE-2024-7264, CVE-2024-8006, CVE-2024-8096, CVE-2024-9681, CVE-2024-11053, CVE-2024-12718, CVE-2024-41996, CVE-2024-47619, CVE-2024-52533, CVE-2025-0167, CVE-2025-0665, CVE-2025-0725, CVE-2025-1390, CVE-2025-3360, CVE-2025-4138, CVE-2025-4330, CVE-2025-4373, CVE-2025-4435, CVE-2025-4516, CVE-2025-4517, CVE-2025-6141, CVE-2025-9086, CVE-2025-9230, CVE-2025-9231, CVE-2025-9232, CVE-2025-10148, CVE-2025-27587, CVE-2025-32433, CVE-2025-38084, CVE-2025-38085, CVE-2025-38086, CVE-2025-38345, CVE-2025-38350, CVE-2025-38498, CVE-2025-39839, CVE-2025-39841, CVE-2025-39846, CVE-2025-39853, CVE-2025-39860, CVE-2025-39864, CVE-2025-39865, CVE-2025-59375) SCALANCE XCH328 (6GK5328-4TS01-2EC2) vers:intdot/<3.3 (CVE-2022-48174, CVE-2023-7256,…
Source published · CISA Cybersecurity Advisory

Siemens COMOS

View CSAF Summary COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where…
Read more of the source summary
fixes are not, or not yet available. The following versions of Siemens COMOS are affected: COMOS V10.4 vers:intdot/<10.4.5, vers:intdot/<10.4.5 (CVE-2024-47875, CVE-2025-2783) COMOS V10.4.5 vers:intdot/<10.4.5.0.2 (CVE-2024-11053, CVE-2025-10148) COMOS V10.5 vers:intdot/<10.5.2, vers:intdot/<10.5.2 (CVE-2025-2783, CVE-2024-47875) COMOS V10.6 vers:all/* (CVE-2024-11053, CVE-2025-10148, CVE-2025-40800, CVE-2025-40801) CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens COMOS Exposure of Sensitive Information to an Unauthorized Actor, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Input Validation, Generation of Predictable Numbers or Identifiers, Improper Certificate Validation Background Critical Infrastructure…
Source published · CISA Cybersecurity Advisory

Hitachi Energy SuprOS

View CSAF Summary Hitachi Energy is aware of a vulnerability that affects the SuprOS product versions listed in this document. An attacker successfully exploiting this vulnerability can cause confidentiality, integrity and availability impacts. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SuprOS are affected: SuprOS…
Read more of the source summary
vers:SuprOS/<=9.2.1, 9.2.2.0 (CVE-2025-7740, CVE-2025-7740) CVSS Vendor Equipment Vulnerabilities v3 8.8 Hitachi Energy Hitachi Energy SuprOS Use of Default Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7740 A default credentials vulnerability exists in the SuprOS product. If exploited, this could allow an authenticated local attacker to gain access through an admin account created during product deployment. View CVE Details Affected Products Hitachi Energy SuprOS Vendor: Hitachi Energy Product Version: SuprOS 9.2.1 and below, SuprOS 9.2.2.0 Product Status: known_affected Remediations…
Source published · CISA Cybersecurity Advisory

ZOLL ePCR IOS Mobile Application

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to protected health information (PHI) or device telemetry. The following versions of ZOLL ePCR IOS Mobile Application are affected: ePCR IOS Mobile Application 2.6.7 (CVE-2025-12699) CVSS Vendor Equipment Vulnerabilities v3 5.5 ZOLL ZOLL ePCR IOS Mobile Application Insertion of Sensitive Information…
Read more of the source summary
into Externally-Accessible File or Directory Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-12699 The ZOLL ePCR IOS application reflects unsanitized user input into a WebView. Attacker-controlled strings placed into PCR fields (run number, incident, call sign, notes) are interpreted as HTML/JS when the app prints or renders that content. In the proof of concept (POC), injected scripts return local file content, which would allow arbitrary local file reads from the app's runtime context. These local files contain device and user data within the ePCR medical application, and if exposed, would allow an attacker to access protected…
Source published · CISA Cybersecurity Advisory

CISA Adds Six Known Exploited Vulnerabilities to Catalog

CISA has added six new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-21510 Microsoft Windows Shell Protection Mechanism Failure Vulnerability CVE-2026-21513 Microsoft MSHTML Framework Security Feature Bypass Vulnerability CVE-2026-21514 Microsoft Office Word Reliance on Untrusted Inputs in a Security Decision Vulnerability CVE-2026-21519…
Read more of the source summary
Microsoft Windows Type Confusion Vulnerability CVE-2026-21525 Microsoft Windows NULL Pointer Dereference Vulnerability CVE-2026-21533 Windows Remote Desktop Services Elevation of Privilege Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See…
Source published · CISA Cybersecurity Advisory

AVEVA PI to CONNECT Agent

View CSAF Summary Successful exploitation of this vulnerability could result in an unauthorized access to the proxy server. The following versions of AVEVA PI to CONNECT Agent are affected: PI to CONNECT Agent <=v2.4.2520 (CVE-2026-1495) CVSS Vendor Equipment Vulnerabilities v3 6.5 AVEVA AVEVA PI to CONNECT Agent Insertion of Sensitive Information into Log File Background Critical Infrastructure Sectors: Critical…
Read more of the source summary
Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-1495 The vulnerability, if exploited, could allow an attacker with Event Log Reader (S-1-5-32-573) privileges to obtain proxy details, including URL and proxy credentials, from the PI to CONNECT event log files. This could enable unauthorized access to the proxy server. View CVE Details Affected Products AVEVA PI to CONNECT Agent Vendor: AVEVA Product Version: AVEVA PI to CONNECT Agent: <=v2.4.2520 Product Status: known_affected Remediations Mitigation AVEVA recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. Vendor fix Users of affected…
Source published · CISA Cybersecurity Advisory

ZLAN Information Technology Co. ZLAN5143D

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker bypassing authentication, or resetting the device password. The following versions of ZLAN Information Technology Co. ZLAN5143D are affected: ZLAN5143D v1.600 (CVE-2026-25084, CVE-2026-24789) CVSS Vendor Equipment Vulnerabilities v3 9.8 ZLAN Information Technology Co. ZLAN Information Technology Co. ZLAN5143D Missing…
Read more of the source summary
Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-25084 Authentication for the device can be bypassed by directly accessing internal URLs. View CVE Details Affected Products ZLAN Information Technology Co. ZLAN5143D Vendor: ZLAN Information Technology Co. Product Version: ZLAN Information Technology Co. ZLAN5143D: v1.600 Product Status: known_affected Remediations Vendor fix ZLAN Information Technology Co. did not respond to CISA's attempts at coordination. Users of ZLAN5143D devices are encouraged to contact ZLAN and keep their systems up to date. https://www.zlmcu.com/en/contatct_us.htm Relevant CWE: CWE-306…
Source published · CISA Cybersecurity Advisory

​​Barriers to Secure OT Communication: Why Johnny Can’t Authenticate​

CISA released the guidance, Barriers to Secure OT Communication: Why Johnny Can’t Authenticate, which highlights the known issues with insecure-by-design legacy industrial protocols and seeks to understand why the technology to secure these protocols is not widely adopted. CISA developed this guidance in partnership with operational technology (OT) equipment manufacturers and standard development organizations, by…
Read more of the source summary
interviewing OT asset owners and operators to understand: What motivates owners and operators to secure communication, and What barriers prevent successful adoption from design through deployment and operations. Legacy OT protocols lack strong protections against data alteration, device impersonation, and unauthorized access, making critical infrastructure vulnerable to cyber threats. Securing these protocols requires solutions that are practical for current operators as well as cyber experts. Based on the research conducted, CISA provides recommendations for how owners and operators can avoid the negative experiences of their peers, as well as recommendations to OT manufacturers to drive sustainable, more usable capabilities. Barriers to Secure Communication: Why Johnny…
Source published · CISA Cybersecurity Advisory

AVEVA PI Data Archive

View CSAF Summary Successful exploitation of this vulnerability could result in a denial-of-service condition. The following versions of AVEVA PI Data Archive are affected: PI Data Archive PI Server <=2018_SP3_Patch_7 (CVE-2026-1507) PI Data Archive PI Server 2023 (CVE-2026-1507) PI Data Archive PI Server 2023_Patch_1 (CVE-2026-1507) PI Data Archive PI Server 2024 (CVE-2026-1507) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 7.5 AVEVA AVEVA PI Data Archive Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-1507 The affected products are vulnerable to an uncaught exception that could allow an unauthenticated attacker to remotely crash core PI services resulting in a denial of service. View CVE Details Affected Products AVEVA PI Data Archive Vendor: AVEVA Product Version: AVEVA PI Data Archive PI Server: <=2018_SP3_Patch_7, AVEVA PI Data Archive PI Server: 2023, AVEVA PI Data Archive PI Server: 2023_Patch_1, AVEVA PI Data Archive PI Server: 2024 Product Status: known_affected Remediations Mitigation AVEVA recommends that organizations…
Source published · CISA Cybersecurity Advisory

Yokogawa FAST/TOOLS

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to redirected users to malicious sites, decrypt communications, perform a man-in-the-middle (MITM) attack, execute malicious scripts, steal files, and perform other various attacks. The following versions of Yokogawa FAST/TOOLS are affected: FAST/TOOLS >=R9.01|<=R10.04 (CVE-2025-66594, CVE-2025-66595, CVE-2025-66597,…
Read more of the source summary
CVE-2025-66598, CVE-2025-66599, CVE-2025-66600, CVE-2025-66601, CVE-2025-66602, CVE-2025-66603, CVE-2025-66604, CVE-2025-66605, CVE-2025-66606, CVE-2025-66607, CVE-2025-66608) CVSS Vendor Equipment Vulnerabilities v3 8.2 Yokogawa Yokogawa FAST/TOOLS Generation of Error Message Containing Sensitive Information, Cross-Site Request Forgery (CSRF), Use of a Broken or Risky Cryptographic Algorithm, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Improperly Implemented Security Check for Standard, Reliance on IP Address for Authentication, Cleartext Transmission of Sensitive Information, Exposure of Private Personal Information to an Unauthorized Actor, Improper Neutralization of Invalid Characters in Identifiers in Web Pages, Path Traversal: '\..\filename'…
Source published · CISA Cybersecurity Advisory

Poland Energy Sector Cyber Incident Highlights OT and ICS Security Gaps

The purpose of this Alert is to amplify Poland’s Computer Emergency Response Team (CERT Polska’s) Energy Sector Incident Report published on Jan. 30, 2026, and highlight key mitigations for Energy Sector stakeholders. In December 2025, a malicious cyber actor(s) targeted and compromised operational technology (OT) and industrial control systems (ICS) in Poland’s Energy Sector—specifically renewable energy plants, a…
Read more of the source summary
combined heat and power plant, and a manufacturing sector company—in a cyber incident. The malicious cyber activity highlights the need for critical infrastructure entities with vulnerable edge devices to act now to strengthen their cybersecurity posture against cyber threat activities targeting OT and ICS. A malicious cyber actor(s) gained initial access in this incident through vulnerable internet-facing edge devices, subsequently deploying wiper malware and causing damage to remote terminal units (RTUs). The malicious cyber activity caused loss of view and control between facilities and distribution system operators, destroyed data on human machine interfaces (HMIs), and corrupted system firmware on OT devices. While the affected renewable energy systems continued…
Source published · CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-11953 React Native Community CLI OS Command Injection Vulnerability CVE-2026-24423 SmarterTools SmarterMail Missing Authentication for Critical Function Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant…
Read more of the source summary
risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing