View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition and memory corruption. The following versions of o6 Automation GmbH Open62541 are affected: Open62541 >=1.5-rc1|<1.5-rc2 (CVE-2026-1301) CVSS Vendor Equipment Vulnerabilities v3 5.7 o6 Automation GmbH o6 Automation GmbH Open62541 Out-of-bounds Write Background Critical Infrastructure…
Read more of the source summary
Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-1301 In builds with PubSub and JSON enabled, a crafted JSON message can cause the decoder to write beyond a heap-allocated array before authentication, reliably crashing the process and corrupting memory. View CVE Details Affected Products o6 Automation GmbH Open62541 Vendor: o6 Automation GmbH Product Version: o6 Automation GmbH Open62541: >=1.5-rc1|<1.5-rc2 Product Status: known_affected Remediations Mitigation o6 Automation GmbH recommends users upgrade to the stable release of v1.5.0. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.7 MEDIUM…
View CSAF Summary Hitachi Energy is aware of a vulnerability that affects FOX61x product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only…
Read more of the source summary
if FOX61x devices are configured to use remote RADIUS authentication. The following versions of Hitachi Energy FOX61x are affected: FOX61x R18, vers:FOX61x/<=R17A (CVE-2024-3596, CVE-2024-3596) CVSS Vendor Equipment Vulnerabilities v3 9 Hitachi Energy Hitachi Energy FOX61x Improper Enforcement of Message Integrity During Transmission in a Communication Channel Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-3596 The RADIUS protocol under RFC 2865 is vulnerable to forgery attacks that allow a local attacker to modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response by exploiting a chosen-prefix…
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial-of-service condition on the affected product. The following versions of Mitsubishi Electric MELSEC iQ-R Series are affected: MELSEC iQ-R Series R08/16/32/120PCPU firmware <=48 (CVE-2025-15080)…
Read more of the source summary
CVSS Vendor Equipment Vulnerabilities v3 9.4 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-R Series Improper Validation of Specified Quantity in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-15080 An information disclosure, information tampering, and denial-of-service vulnerability exists in Mitsubishi Electric proprietary protocol communication and SLMP communication used in FA products. An attacker may be able to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial-of-service condition on the affected product by sending a specially crafted packet…
View CSAF Summary Hitachi Energy is aware of a vulnerability that affects XMC20 product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only if…
Read more of the source summary
XMC20 devices are configured to use remote RADIUS authentication. The following versions of Hitachi Energy XMC20 are affected: XMC20 R18, vers:XMC20/<=R17A (CVE-2024-3596, CVE-2024-3596) CVSS Vendor Equipment Vulnerabilities v3 9 Hitachi Energy Hitachi Energy XMC20 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-3596 The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker. An attacker can modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response using a chosen-prefix…
Introduction The Cybersecurity and Infrastructure Security Agency (CISA), the Federal Bureau of Investigation (FBI), and the U.K.’s National Cyber Security Centre (NCSC) are releasing this fact sheet to urge defensive action against malicious cyber activity by nation-state threat actors. Nation-state threat actors exploit end-of-support (EOS) edge devices—including, but not limited to, load balancers, firewalls,…
Read more of the source summary
routers, and virtual private network (VPN) gateways—to gain network access, maintain presence, and compromise sensitive data. Organizations using EOS devices are particularly vulnerable to compromise, especially if they are using EOS devices exposed to the public internet or external systems at the network’s “edge.” CISA’s Binding Operational Directive (BOD) 26-02: Mitigating Risk From End-of-Support Edge Devices requires U.S. Federal Civilian Executive Branch (FCEB) agencies to manage the lifecycle of edge devices to defend against malicious cyber activity. Although the BOD 26-02 requirement only applies to FCEB agencies, CISA, FBI, and NCSC strongly encourage organizations to follow the guidance in the BOD and this fact sheet to safeguard systems, data, and operations…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary shell commands and the disclosure of sensitive system information. The following versions of Ilevia EVE X1 Server are affected: EVE X1 <=4.7.18.0 (CVE-2025-34185, CVE-2025-34184, CVE-2025-34183, CVE-2025-34186, CVE-2025-34187, CVE-2025-34517, CVE-2025-34518, CVE-2025-34512, CVE-2025-34513) CVSS Vendor…
Read more of the source summary
Equipment Vulnerabilities v3 9.8 Ilevia Ilevia EVE X1 Server Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Insertion of Sensitive Information into Log File, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Italy Vulnerabilities Expand All + CVE-2025-34185 Ilevia EVE X1 Server contains a pre-authentication file disclosure vulnerability via the 'db_log' POST parameter. Remote attackers can retrieve arbitrary files from the server, exposing sensitive system information and credentials.…
View CSAF Summary Successful exploitation of this vulnerability could result in unauthorized users gaining administrative access to affected closed circuit television cameras. The following versions of TP-Link Systems Inc. VIGI Series IP Camera are affected: VIGI Cx45 Series Models C345, C445 <=3.1.0_Build_250820_Rel.57668n (CVE-2026-0629) VIGI Cx55 Series Models C355, C455 <=3.1.0_Build_250820_Rel.58873n…
Read more of the source summary
(CVE-2026-0629) VIGI Cx85 Series Models C385, C485 <=3.0.2_Build_250630_Rel.71279n (CVE-2026-0629) VIGI C340S Series <=3.1.0_Build_250625_Rel.65381n (CVE-2026-0629) VIGI C540S Series Models C540S, EasyCam C540S <=3.1.0_Build_250625_Rel.66601n (CVE-2026-0629) VIGI C540V Series <=2.1.0_Build_250702_Rel.54300n (CVE-2026-0629) VIGI C250 Series <=2.1.0_Build_250702_Rel.54301n (CVE-2026-0629) VIGI Cx50 Series Models C350, C450 <=2.1.0_Build_250702_Rel.54294n (CVE-2026-0629) VIGI Cx20I (1.0) Series Models C220I 1.0, C320I 1.0, C420I 1.0 <=2.1.0_Build_251014_Rel.58331n (CVE-2026-0629) VIGI Cx20I (1.20) Series Models C220I 1.20, C320I 1.20, C420I 1.20 <=2.1.0_Build_250701_Rel.44071n (CVE-2026-0629) VIGI Cx30I (1.0) Series Models C230I 1.0, C330I 1.0, C430I 1.0…
View CSAF Summary Successful exploitation of this vulnerability could result in an unauthenticated attacker modifying critical device settings or factory resetting the device. The following versions of Synectix LAN 232 TRIO are affected: LAN 232 TRIO vers:all/* (CVE-2026-1633) CVSS Vendor Equipment Vulnerabilities v3 10 Synectix Synectix LAN 232 TRIO Missing Authentication for Critical Function Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing, Emergency Services, Energy, Information Technology, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1633 The Synectix LAN 232 TRIO 3-Port serial to ethernet adapter exposes its web management interface without requiring authentication, allowing unauthenticated users to modify critical device settings or factory reset the device. View CVE Details Affected Products Synectix LAN 232 TRIO Vendor: Synectix Product Version: Synectix LAN 232 TRIO: vers:all/* Product Status: known_affected Remediations Mitigation The affected products should be considered end-of-life, as Synectix is no longer in business and therefore…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take full control of the device. The following versions of Avation Light Engine Pro are affected: Light Engine Pro vers:all/* (CVE-2026-1341) CVSS Vendor Equipment Vulnerabilities v3 9.8 Avation Avation Light Engine Pro Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial…
Read more of the source summary
Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Australia Vulnerabilities Expand All + CVE-2026-1341 Avation Light Engine Pro exposes its configuration and control interface without any authentication or access control. View CVE Details Affected Products Avation Light Engine Pro Vendor: Avation Product Version: Avation Light Engine Pro: vers:all/* Product Status: known_affected Remediations Vendor fix Avation has not responded to CISA's request to coordinate. Users of Avation Light Engine Pro are encouraged to contact Avation for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to, modify, delete, or destroy information stored on the system where the affected product is installed, or cause a denial-of-service condition on the affected system. The following versions of Mitsubishi Electric FREQSHIP-mini for Windows are affected: FREQSHIP-mini for Windows >=8.0.0|<=8.0.2…
Read more of the source summary
(CVE-2025-10314) CVSS Vendor Equipment Vulnerabilities v3 8.8 Mitsubishi Electric Mitsubishi Electric FREQSHIP-mini for Windows Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology, Healthcare and Public Health, Government Services and Facilities Countries/Areas Deployed: Japan Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-10314 A malicious code execution vulnerability exists in Mitsubishi's small-capacity UPS shutdown software, FREQSHIP-mini for Windows, due to incorrect default permissions. A local attacker may be able to execute arbitrary code with system privileges by replacing service executable or DLL files in the installation directory with specially crafted files.…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.