View CSAF Summary SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SINEC OS are affected: RUGGEDCOM RST2428P (6GK6242-6PA00) vers:intdot/<3.3 (CVE-2022-48174, CVE-2023-7256, CVE-2023-39810, CVE-2023-42363, CVE-2023-42364, CVE-2023-42365,…
View CSAF Summary COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where…
Read more of the source summary
fixes are not, or not yet available. The following versions of Siemens COMOS are affected: COMOS V10.4 vers:intdot/<10.4.5, vers:intdot/<10.4.5 (CVE-2024-47875, CVE-2025-2783) COMOS V10.4.5 vers:intdot/<10.4.5.0.2 (CVE-2024-11053, CVE-2025-10148) COMOS V10.5 vers:intdot/<10.5.2, vers:intdot/<10.5.2 (CVE-2025-2783, CVE-2024-47875) COMOS V10.6 vers:all/* (CVE-2024-11053, CVE-2025-10148, CVE-2025-40800, CVE-2025-40801) CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens COMOS Exposure of Sensitive Information to an Unauthorized Actor, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Input Validation, Generation of Predictable Numbers or Identifiers, Improper Certificate Validation Background Critical Infrastructure…
View CSAF Summary Hitachi Energy is aware of a vulnerability that affects the SuprOS product versions listed in this document. An attacker successfully exploiting this vulnerability can cause confidentiality, integrity and availability impacts. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SuprOS are affected: SuprOS…
Read more of the source summary
vers:SuprOS/<=9.2.1, 9.2.2.0 (CVE-2025-7740, CVE-2025-7740) CVSS Vendor Equipment Vulnerabilities v3 8.8 Hitachi Energy Hitachi Energy SuprOS Use of Default Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7740 A default credentials vulnerability exists in the SuprOS product. If exploited, this could allow an authenticated local attacker to gain access through an admin account created during product deployment. View CVE Details Affected Products Hitachi Energy SuprOS Vendor: Hitachi Energy Product Version: SuprOS 9.2.1 and below, SuprOS 9.2.2.0 Product Status: known_affected Remediations…
View CSAF Summary Successful exploitation of this vulnerability could result in an unauthorized access to the proxy server. The following versions of AVEVA PI to CONNECT Agent are affected: PI to CONNECT Agent <=v2.4.2520 (CVE-2026-1495) CVSS Vendor Equipment Vulnerabilities v3 6.5 AVEVA AVEVA PI to CONNECT Agent Insertion of Sensitive Information into Log File Background Critical Infrastructure Sectors: Critical…
Read more of the source summary
Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-1495 The vulnerability, if exploited, could allow an attacker with Event Log Reader (S-1-5-32-573) privileges to obtain proxy details, including URL and proxy credentials, from the PI to CONNECT event log files. This could enable unauthorized access to the proxy server. View CVE Details Affected Products AVEVA PI to CONNECT Agent Vendor: AVEVA Product Version: AVEVA PI to CONNECT Agent: <=v2.4.2520 Product Status: known_affected Remediations Mitigation AVEVA recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. Vendor fix Users of affected…
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker bypassing authentication, or resetting the device password. The following versions of ZLAN Information Technology Co. ZLAN5143D are affected: ZLAN5143D v1.600 (CVE-2026-25084, CVE-2026-24789) CVSS Vendor Equipment Vulnerabilities v3 9.8 ZLAN Information Technology Co. ZLAN Information Technology Co. ZLAN5143D Missing…
Read more of the source summary
Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-25084 Authentication for the device can be bypassed by directly accessing internal URLs. View CVE Details Affected Products ZLAN Information Technology Co. ZLAN5143D Vendor: ZLAN Information Technology Co. Product Version: ZLAN Information Technology Co. ZLAN5143D: v1.600 Product Status: known_affected Remediations Vendor fix ZLAN Information Technology Co. did not respond to CISA's attempts at coordination. Users of ZLAN5143D devices are encouraged to contact ZLAN and keep their systems up to date. https://www.zlmcu.com/en/contatct_us.htm Relevant CWE: CWE-306…
The purpose of this Alert is to amplify Poland’s Computer Emergency Response Team (CERT Polska’s) Energy Sector Incident Report published on Jan. 30, 2026, and highlight key mitigations for Energy Sector stakeholders. In December 2025, a malicious cyber actor(s) targeted and compromised operational technology (OT) and industrial control systems (ICS) in Poland’s Energy Sector—specifically renewable energy plants, a…
Read more of the source summary
combined heat and power plant, and a manufacturing sector company—in a cyber incident. The malicious cyber activity highlights the need for critical infrastructure entities with vulnerable edge devices to act now to strengthen their cybersecurity posture against cyber threat activities targeting OT and ICS. A malicious cyber actor(s) gained initial access in this incident through vulnerable internet-facing edge devices, subsequently deploying wiper malware and causing damage to remote terminal units (RTUs). The malicious cyber activity caused loss of view and control between facilities and distribution system operators, destroyed data on human machine interfaces (HMIs), and corrupted system firmware on OT devices. While the affected renewable energy systems continued…
View CSAF Summary Successful exploitation of this vulnerability could result in a denial-of-service condition. The following versions of AVEVA PI Data Archive are affected: PI Data Archive PI Server <=2018_SP3_Patch_7 (CVE-2026-1507) PI Data Archive PI Server 2023 (CVE-2026-1507) PI Data Archive PI Server 2023_Patch_1 (CVE-2026-1507) PI Data Archive PI Server 2024 (CVE-2026-1507) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 7.5 AVEVA AVEVA PI Data Archive Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-1507 The affected products are vulnerable to an uncaught exception that could allow an unauthenticated attacker to remotely crash core PI services resulting in a denial of service. View CVE Details Affected Products AVEVA PI Data Archive Vendor: AVEVA Product Version: AVEVA PI Data Archive PI Server: <=2018_SP3_Patch_7, AVEVA PI Data Archive PI Server: 2023, AVEVA PI Data Archive PI Server: 2023_Patch_1, AVEVA PI Data Archive PI Server: 2024 Product Status: known_affected Remediations Mitigation AVEVA recommends that organizations…
CISA released the guidance, Barriers to Secure OT Communication: Why Johnny Can’t Authenticate, which highlights the known issues with insecure-by-design legacy industrial protocols and seeks to understand why the technology to secure these protocols is not widely adopted. CISA developed this guidance in partnership with operational technology (OT) equipment manufacturers and standard development organizations, by…
Read more of the source summary
interviewing OT asset owners and operators to understand: What motivates owners and operators to secure communication, and What barriers prevent successful adoption from design through deployment and operations. Legacy OT protocols lack strong protections against data alteration, device impersonation, and unauthorized access, making critical infrastructure vulnerable to cyber threats. Securing these protocols requires solutions that are practical for current operators as well as cyber experts. Based on the research conducted, CISA provides recommendations for how owners and operators can avoid the negative experiences of their peers, as well as recommendations to OT manufacturers to drive sustainable, more usable capabilities. Barriers to Secure Communication: Why Johnny…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to redirected users to malicious sites, decrypt communications, perform a man-in-the-middle (MITM) attack, execute malicious scripts, steal files, and perform other various attacks. The following versions of Yokogawa FAST/TOOLS are affected: FAST/TOOLS >=R9.01|<=R10.04 (CVE-2025-66594, CVE-2025-66595, CVE-2025-66597,…
Read more of the source summary
CVE-2025-66598, CVE-2025-66599, CVE-2025-66600, CVE-2025-66601, CVE-2025-66602, CVE-2025-66603, CVE-2025-66604, CVE-2025-66605, CVE-2025-66606, CVE-2025-66607, CVE-2025-66608) CVSS Vendor Equipment Vulnerabilities v3 8.2 Yokogawa Yokogawa FAST/TOOLS Generation of Error Message Containing Sensitive Information, Cross-Site Request Forgery (CSRF), Use of a Broken or Risky Cryptographic Algorithm, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Improperly Implemented Security Check for Standard, Reliance on IP Address for Authentication, Cleartext Transmission of Sensitive Information, Exposure of Private Personal Information to an Unauthorized Actor, Improper Neutralization of Invalid Characters in Identifiers in Web Pages, Path Traversal: '\..\filename'…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to protected health information (PHI) or device telemetry. The following versions of ZOLL ePCR IOS Mobile Application are affected: ePCR IOS Mobile Application 2.6.7 (CVE-2025-12699) CVSS Vendor Equipment Vulnerabilities v3 5.5 ZOLL ZOLL ePCR IOS Mobile Application Insertion of Sensitive Information…
Read more of the source summary
into Externally-Accessible File or Directory Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-12699 The ZOLL ePCR IOS application reflects unsanitized user input into a WebView. Attacker-controlled strings placed into PCR fields (run number, incident, call sign, notes) are interpreted as HTML/JS when the app prints or renders that content. In the proof of concept (POC), injected scripts return local file content, which would allow arbitrary local file reads from the app's runtime context. These local files contain device and user data within the ePCR medical application, and if exposed, would allow an attacker to access protected…