CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2024-43468 Microsoft Configuration Manager SQL Injection Vulnerability CVE-2025-15556 Notepad++ Download of Code Without Integrity Check Vulnerability CVE-2025-40536 SolarWinds Web Help Desk Security Control Bypass Vulnerability CVE-2026-20700 Apple Multiple Buffer Overflow…
Read more of the source summary
Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing…
View CSAF Summary Hitachi Energy is aware of a vulnerability that affects the SuprOS product versions listed in this document. An attacker successfully exploiting this vulnerability can cause confidentiality, integrity and availability impacts. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SuprOS are affected: SuprOS…
Read more of the source summary
vers:SuprOS/<=9.2.1, 9.2.2.0 (CVE-2025-7740, CVE-2025-7740) CVSS Vendor Equipment Vulnerabilities v3 8.8 Hitachi Energy Hitachi Energy SuprOS Use of Default Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7740 A default credentials vulnerability exists in the SuprOS product. If exploited, this could allow an authenticated local attacker to gain access through an admin account created during product deployment. View CVE Details Affected Products Hitachi Energy SuprOS Vendor: Hitachi Energy Product Version: SuprOS 9.2.1 and below, SuprOS 9.2.2.0 Product Status: known_affected Remediations…
View CSAF Summary Polarion before V2506 contains a vulnerability that could allow authenticated remote attackers to conduct cross-site scripting attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Polarion are affected: Polarion V2404 vers:intdot/<2404.5 (CVE-2025-40587) Polarion V2410 vers:intdot/<2410.2…
Read more of the source summary
(CVE-2025-40587) CVSS Vendor Equipment Vulnerabilities v3 7.6 Siemens Siemens Polarion Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-40587 The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application. View CVE Details Affected Products Siemens Polarion Vendor: Siemens Product Version: Polarion V2404, Polarion V2410 Product Status:…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to obtain remote code execution. The following versions of Airleader Master are affected: Airleader Master <=6.381 (CVE-2026-1358) CVSS Vendor Equipment Vulnerabilities v3 9.8 Airleader GmbH Airleader Master Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Chemical, Critical…
Read more of the source summary
Manufacturing, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-1358 Airleader Master versions 6.381 and prior allow for file uploads without restriction to multiple webpages running maximum privileges. This could allow an unauthenticated user to potentially obtain remote code execution on the server. View CVE Details Affected Products Airleader Master Vendor: Airleader GmbH Product Version: Airleader GmbH Airleader Master: <=6.381 Product Status: known_affected Remediations Vendor fix Airleader recommends that users upgrade Airleader Master to version 6.386 or later. Mitigation Users of Airleader Master are…
View CSAF Summary Versions V6.0 through V8 QU1 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could lead to code execution in the context of the current process.…
Read more of the source summary
Siemens has released instructions how to update the CodeMeter Runtime component and recommends to apply the update on affected systems. The following versions of Siemens Desigo CC Product Family and SENTRON Powermanager are affected: Desigo CC family V6 vers:all/* (CVE-2023-38545) Desigo CC family V7 vers:all/* (CVE-2023-38545) Desigo CC family V8: All versions prior to V8.0 QU2 SENTRON Powermanager V6 vers:all/* (CVE-2023-38545) SENTRON Powermanager V7 vers:all/* (CVE-2023-38545) SENTRON Powermanager V8: All versions prior to V8.0 QU2 CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens Desigo CC Product Family and SENTRON Powermanager Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide…
View CSAF Summary SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SINEC OS are affected: RUGGEDCOM RST2428P (6GK6242-6PA00) vers:intdot/<3.3 (CVE-2022-48174, CVE-2023-7256, CVE-2023-39810, CVE-2023-42363, CVE-2023-42364, CVE-2023-42365,…
View CSAF Summary COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where…
Read more of the source summary
fixes are not, or not yet available. The following versions of Siemens COMOS are affected: COMOS V10.4 vers:intdot/<10.4.5, vers:intdot/<10.4.5 (CVE-2024-47875, CVE-2025-2783) COMOS V10.4.5 vers:intdot/<10.4.5.0.2 (CVE-2024-11053, CVE-2025-10148) COMOS V10.5 vers:intdot/<10.5.2, vers:intdot/<10.5.2 (CVE-2025-2783, CVE-2024-47875) COMOS V10.6 vers:all/* (CVE-2024-11053, CVE-2025-10148, CVE-2025-40800, CVE-2025-40801) CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens COMOS Exposure of Sensitive Information to an Unauthorized Actor, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Input Validation, Generation of Predictable Numbers or Identifiers, Improper Certificate Validation Background Critical Infrastructure…
CISA released the guidance, Barriers to Secure OT Communication: Why Johnny Can’t Authenticate, which highlights the known issues with insecure-by-design legacy industrial protocols and seeks to understand why the technology to secure these protocols is not widely adopted. CISA developed this guidance in partnership with operational technology (OT) equipment manufacturers and standard development organizations, by…
Read more of the source summary
interviewing OT asset owners and operators to understand: What motivates owners and operators to secure communication, and What barriers prevent successful adoption from design through deployment and operations. Legacy OT protocols lack strong protections against data alteration, device impersonation, and unauthorized access, making critical infrastructure vulnerable to cyber threats. Securing these protocols requires solutions that are practical for current operators as well as cyber experts. Based on the research conducted, CISA provides recommendations for how owners and operators can avoid the negative experiences of their peers, as well as recommendations to OT manufacturers to drive sustainable, more usable capabilities. Barriers to Secure Communication: Why Johnny…
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker bypassing authentication, or resetting the device password. The following versions of ZLAN Information Technology Co. ZLAN5143D are affected: ZLAN5143D v1.600 (CVE-2026-25084, CVE-2026-24789) CVSS Vendor Equipment Vulnerabilities v3 9.8 ZLAN Information Technology Co. ZLAN Information Technology Co. ZLAN5143D Missing…
Read more of the source summary
Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-25084 Authentication for the device can be bypassed by directly accessing internal URLs. View CVE Details Affected Products ZLAN Information Technology Co. ZLAN5143D Vendor: ZLAN Information Technology Co. Product Version: ZLAN Information Technology Co. ZLAN5143D: v1.600 Product Status: known_affected Remediations Vendor fix ZLAN Information Technology Co. did not respond to CISA's attempts at coordination. Users of ZLAN5143D devices are encouraged to contact ZLAN and keep their systems up to date. https://www.zlmcu.com/en/contatct_us.htm Relevant CWE: CWE-306…
View CSAF Summary Successful exploitation of this vulnerability could result in a denial-of-service condition. The following versions of AVEVA PI Data Archive are affected: PI Data Archive PI Server <=2018_SP3_Patch_7 (CVE-2026-1507) PI Data Archive PI Server 2023 (CVE-2026-1507) PI Data Archive PI Server 2023_Patch_1 (CVE-2026-1507) PI Data Archive PI Server 2024 (CVE-2026-1507) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 7.5 AVEVA AVEVA PI Data Archive Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-1507 The affected products are vulnerable to an uncaught exception that could allow an unauthenticated attacker to remotely crash core PI services resulting in a denial of service. View CVE Details Affected Products AVEVA PI Data Archive Vendor: AVEVA Product Version: AVEVA PI Data Archive PI Server: <=2018_SP3_Patch_7, AVEVA PI Data Archive PI Server: 2023, AVEVA PI Data Archive PI Server: 2023_Patch_1, AVEVA PI Data Archive PI Server: 2024 Product Status: known_affected Remediations Mitigation AVEVA recommends that organizations…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.