· CISA Cybersecurity Advisory

Mobility46 mobility46.se

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Mobility46 mobility46.se are affected: mobility46.se vers:all/* (CVE-2026-27028, CVE-2026-26305, CVE-2026-27647, CVE-2026-22878) CVSS Vendor Equipment Vulnerabilities v3 9.4 Mobility46 Mobility46 mobility46.se Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-27028 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-26305 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27647 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-22878 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Mobility46 mobility46.se Vendor: Mobility46 Product Version: Mobility46 mobility46.se: vers:all/* Product Status: known_affected Remediations Vendor fix Mobility46 did not respond to CISA's request for coordination. Contact Mobility46 using their contact page here: https://www.mobility46.se/en/contact-us for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CloudCharge cloudcharge.se

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of CloudCharge cloudcharge.se are affected: cloudcharge.se vers:all/* (CVE-2026-20781, CVE-2026-25114, CVE-2026-27652, CVE-2026-20733)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of CloudCharge cloudcharge.se are affected: cloudcharge.se vers:all/* (CVE-2026-20781, CVE-2026-25114, CVE-2026-27652, CVE-2026-20733) CVSS Vendor Equipment Vulnerabilities v3 9.4 CloudCharge CloudCharge cloudcharge.se Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-20781 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25114 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27652 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-20733 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products CloudCharge cloudcharge.se Vendor: CloudCharge Product Version: CloudCharge cloudcharge.se: vers:all/* Product Status: known_affected Remediations Mitigation CloudCharge did not respond to CISA's request for coordination. Contact CloudCharge using their contact page here: https://cloudcharge.tech/support/contact/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

EV2GO ev2go.io

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of EV2GO ev2go.io are affected: ev2go.io vers:all/* (CVE-2026-24731, CVE-2026-25945, CVE-2026-20895, CVE-2026-22890) CVSS Vendor…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of EV2GO ev2go.io are affected: ev2go.io vers:all/* (CVE-2026-24731, CVE-2026-25945, CVE-2026-20895, CVE-2026-22890) CVSS Vendor Equipment Vulnerabilities v3 9.4 EV2GO EV2GO ev2go.io Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-24731 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25945 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-20895 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-22890 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products EV2GO ev2go.io Vendor: EV2GO Product Version: EV2GO ev2go.io: vers:all/* Product Status: known_affected Remediations Vendor fix EV2GO did not respond to CISA's request for coordination. Contact EV2GO using their contact page here: https://ev2go.io/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

SWITCH EV swtchenergy.com

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773)…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to impersonate charging stations, hijack sessions, suppress or misroute legitimate traffic to cause large-scale denial of service, and manipulate data sent to the backend. The following versions of SWITCH EV swtchenergy.com are affected: swtchenergy.com vers:all/* (CVE-2026-27767, CVE-2026-25113, CVE-2026-25778, CVE-2026-27773) CVSS Vendor Equipment Vulnerabilities v3 9.4 SWITCH EV SWITCH EV swtchenergy.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-27767 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-25113 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25778 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-27773 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products SWITCH EV swtchenergy.com Vendor: SWITCH EV Product Version: SWITCH EV swtchenergy.com: vers:all/* Product Status: known_affected Remediations Vendor fix SWITCH EV did not respond to CISA's request for coordination. Contact SWITCH EV using their contact page here: https://swtchenergy.com/contact/ for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Chargemap chargemap.com

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Chargemap chargemap.com are affected: chargemap.com vers:all/* (CVE-2026-25851, CVE-2026-20792, CVE-2026-25711, CVE-2026-20791) CVSS Vendor Equipment Vulnerabilities v3 9.4 Chargemap Chargemap chargemap.com Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-25851 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-20792 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or misrouting legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25711 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-20791 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products Chargemap chargemap.com Vendor: Chargemap Product Version: Chargemap chargemap.com: vers:all/* Product Status: known_affected Remediations Vendor fix Chargemap did not respond to CISA's request for coordination. Contact Chargemap using their contact page here: https://chargemap.com/en-us/support for more information. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Johnson Controls, Inc. Frick Controls Quantum HD

View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities can lead to pre-authentication remote code execution, information leak or denial of service. The following versions of Johnson Controls, Inc. Frick Controls Quantum HD are affected: Frick Controls Quantum HD <=10.22 (CVE-2026-21654, CVE-2026-21656, CVE-2026-21657, CVE-2026-21658, CVE-2026-21659, CVE-2026-21660) CVSS Vendor Equipment Vulnerabilities v3 9.1 Johnson Controls, Inc. Johnson Controls, Inc. Frick Controls Quantum HD Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Control of Generation of Code ('Code Injection'), Relative Path Traversal, Plaintext Storage of a Password Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21654 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21656 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21657 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21658 The Frick Controls Quantum HD is vulnerable due to insufficient validation of input in certain parameters that may permit unexpected actions, which could impact the security of the device before authentication occurs. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H CVE-2026-21659 The Frick Controls Quantum HD contains a vulnerability that allows an unauthenticated attacker to execute arbitrary code on the affected device, leading to full system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-23 Relative Path Traversal Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2026-21660 Hardcoded credentials in the Frick Controls Quantum HD create a vulnerability that leads to unauthorized access, exposure of sensitive information, and potential misuse or system compromise. View CVE Details Affected Products Johnson Controls, Inc. Frick Controls Quantum HD Vendor: Johnson Controls, Inc. Product Version: Johnson Controls, Inc. Frick Controls Quantum HD: <=10.22 Product Status: known_affected Remediations Vendor fix The Frick Controls Quantum HD, versions 10.22 through 11, are legacy platforms that have reached end of support. Johnson Controls, Inc. recommends upgrading to the latest platform, Quantum HD Unity, version 12 or higher. The update procedure can be found here (https://frickcontrolsblob.file.core.windows.net/frickweb1/Quantum-HD-Unity/Quantum_HD_Unity_Software_Update_Procedure.pdf?sv=2018-03-28&si=frickweb1-174C1294FA7&sr=f&sig=us0dhk6IWmCvmDvBs02yJvC%2BjnzbxqZmb4QEpVVDkxY%3D). Mitigation After completing the upgrade to version 12, verify full compliance with the hardening guide and apply all recommended security configurations. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-05 at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories. Relevant CWE: CWE-256 Plaintext Storage of a Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.2 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Acknowledgments Noam Moshe of Claroty Research Team 82 reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-26 Date Revision Summary 2026-02-26 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA and Partners Release Guidance for Ongoing Global Exploitation of Cisco SD-WAN Systems

The purpose of this Alert is to provide resources for organizations with Cisco Software-Defined Wide-Area Networking (SD-WAN) systems, including Federal Civilian Executive Branch (FCEB) agencies, to address ongoing exploitation of multiple vulnerabilities. Notably, the Cybersecurity and Infrastructure Security Agency (CISA) has added CVE-2026-20127 and CVE-2022-20775 to its Known Exploited Vulnerabilities (KEV)…
Read full source summary
The purpose of this Alert is to provide resources for organizations with Cisco Software-Defined Wide-Area Networking (SD-WAN) systems, including Federal Civilian Executive Branch (FCEB) agencies, to address ongoing exploitation of multiple vulnerabilities. Notably, the Cybersecurity and Infrastructure Security Agency (CISA) has added CVE-2026-20127 and CVE-2022-20775 to its Known Exploited Vulnerabilities (KEV) Catalog on Feb. 25, 2026. As a result of the malicious cyber activity and vulnerabilities involving Cisco SD-WAN systems, CISA has outlined requirements for FCEB agencies in Emergency Directive (ED) 26-03 to inventory Cisco SD-WAN systems, update them, and assess compromise. CISA and partners have observed malicious cyber actors targeting and compromising Cisco SD-WAN systems of organizations, globally. These actors have been observed exploiting a previously undisclosed authentication bypass vulnerability, CVE-2026-20127, for initial access before escalating privileges using CVE-2022-20775 and establishing long-term persistence in Cisco SD-WAN systems. CISA, National Security Agency (NSA), and international partners Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC), Canadian Centre for Cyber Security (Cyber Centre), New Zealand National Cyber Security Centre (NCSC-NZ), and United Kingdom National Cyber Security Centre (NCSC-UK), hereafter the “authoring organizations,” strongly urge network defenders to immediately 1) inventory all in-scope Cisco SD-WAN systems, 2) collect artifacts, including virtual snapshots and logs off of SD-WAN systems to support threat hunt activities, 3) fully patch Cisco SD-WAN systems with available updates, 4) hunt for evidence of compromise, and 5) concurrently review Cisco’s latest security advisories, Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability and Cisco Catalyst SD-WAN Vulnerabilities, and implement Cisco’s SD-WAN Hardening Guidance.1 To address malicious activity involving vulnerable Cisco SD-WAN systems, CISA issued Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems, which outlines requirements for FCEB agencies to inventory Cisco SD-WAN systems, update them, and assess compromise. Further, CISA released Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems to provide prescriptive actions for FCEB agencies. Cisco’s Catalyst SD-WAN Hardening Guide recommends that network defenders address: Network perimeter controls: Ensure control components are behind a firewall, isolate virtual private network (VPN) 512 interfaces, and use internet protocol (IP) blocks for manually provisioned edge IPs. SD-WAN manager access: Replace the self-signed certificate for the web user interface. Control and data plane security: Use pairwise keys. Session timeout: Limit to the shortest period possible. Logging: Forward to a remote syslog server. CISA and the authoring organizations are providing the following resources: CISA: Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems CISA: Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems Cisco: Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability Cisco: Cisco Catalyst SD-WAN Vulnerabilities Cisco: Cisco Catalyst SD-WAN Hardening Guide ASD’s ACSC: Cisco SD-WAN Threat Hunt Guide, co-sealed by CISA, NSA, Cyber Centre, NCSC-NZ, and NCSC-UK. This guide, based on investigative data, supports network defenders’ detection of and response to the malicious actors’ threat activity Acknowledgements NSA, ASD’s ACSC, Cyber Centre, NCSC-NZ, and NCSC-UK contributed to this alert. Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Notes 1 Cisco Security, “Cisco Catalyst SD-WAN Hardening Guide,” last modified February 9, 2026, https://sec.cloudapps.cisco.com/security/center/resources/Cisco-Catalyst-SD-WAN-HardeningGuide
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2022-20775 Cisco Catalyst SD-WAN Path Traversal Vulnerability CVE-2026-20127 Cisco Catalyst SD-WAN Controller and Manager Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2022-20775 Cisco Catalyst SD-WAN Path Traversal Vulnerability CVE-2026-20127 Cisco Catalyst SD-WAN Controller and Manager Authentication Bypass Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Gardyn Home Kit

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control edge devices, access cloud-based devices and user information without authentication, and pivot to other edge devices managed in the Gardyn cloud environment. The following versions of Gardyn Home Kit are affected: Home Kit Firmware Gardyn Home Kit Mobile Application <2.11.0 (CVE-2025-29628,…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control edge devices, access cloud-based devices and user information without authentication, and pivot to other edge devices managed in the Gardyn cloud environment. The following versions of Gardyn Home Kit are affected: Home Kit Firmware Gardyn Home Kit Mobile Application <2.11.0 (CVE-2025-29628, CVE-2025-29629, CVE-2025-29631, CVE-2025-1242) Gardyn Home Kit Cloud API <2.12.2026 (CVE-2025-29628, CVE-2025-29629, CVE-2025-29631, CVE-2025-1242) CVSS Vendor Equipment Vulnerabilities v3 9.1 Gardyn Gardyn Home Kit Cleartext Transmission of Sensitive Information, Use of Default Credentials, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-29628 A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-319 Cleartext Transmission of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2025-29629 The Gardyn Home Kit uses weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-1392 Use of Default Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2025-29631 The Gardyn Home Kit is vulnerable to command injection through vulnerable methods that do not sanitize input before passing content to the operating system for execution. The vulnerability may allow an attacker to execute arbitrary operating system commands on a target Home Kit. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation For CVE-2025-29631: Gardyn is currently working on a full mitigation to address this vulnerability. As previously stated, Gardyn recommends that users ensure their devices are always updated to the most current firmware version. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2025-1242 The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control. View CVE Details Affected Products Gardyn Home Kit Vendor: Gardyn Product Version: Gardyn Home Kit Firmware: <master.619, Gardyn Gardyn Home Kit Mobile Application: <2.11.0, Gardyn Gardyn Home Kit Cloud API: <2.12.2026 Product Status: known_affected Remediations Mitigation Gardyn states that the relevant fixes are included in the latest version of the Gardyn mobile application. Users are required to run a supported version of the Gardyn App on their phone in order to access Gardyn services and devices. Mitigation The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App. Mitigation For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection. Mitigation Further information on Gardyn security can be found here: https://mygardyn.com/security/ Mitigation Further customer support can be obtained from Gardyn at: support@mygardyn.com Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments Michael Groberman reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-02-24 Date Revision Summary 2026-02-24 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25108 Soliton Systems K.K. FileZen OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25108 Soliton Systems K.K. FileZen OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.