Cybersecurity

CISA Advisories snapshot, Mar 25, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Schneider Electric SCADAPack and RemoteConnect

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and…
Read more of the source summary
loss of confidentiality, integrity of the controller. The following versions of Schneider Electric SCADAPack and RemoteConnect are affected: SCADAPack™ vers:generic/ SCADAPack™ firmware vers:intdot/<9.12.2, 9.12.2, vers:intdot/<9.12.2, 9.12.2 () RemoteConnect vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric SCADAPack and RemoteConnect Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-0667 CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality &…
Source published · CISA Cybersecurity Advisory

CODESYS in Festo Automation Suite

View CSAF Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* FESTO…
Read more of the source summary
Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 FESTO, CODESYS CODESYS in Festo Automation Suite Direct Request ('Forced Browsing'), Untrusted Search Path, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Recursion, Improper Access Control, Use of Insufficiently Random Values, Improper Restriction of Communication Channel to Intended Endpoints, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Input During Web Page Generation ('Cross-site…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-47813 Wing FTP Server Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read more of the source summary
Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3909 Google Skia Out-of-Bounds Write Vulnerability CVE-2026-3910 Google Chromium V8 Unspecified Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational…
Read more of the source summary
Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the…
Source published · CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/*, vers:all/* (CVE-2026-24858, CVE-2025-55018, CVE-2025-62439,…
Read more of the source summary
CVE-2025-64157) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens RUGGEDCOM APE1808 Devices Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Improper Verification of Source of a Communication Channel, Use of Externally-Controlled Format String, Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-55018 An inconsistent interpretation of http requests ('http request smuggling') vulnerability in Fortinet FortiOS 7.6.0, FortiOS 7.4.0 through 7.4.9, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4.3 through…
Source published · CISA Cybersecurity Advisory

Siemens SIDIS Prime

View CSAF Summary SIDIS Prime before V4.0.800 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, and several Node.js packages as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version. The following versions of Siemens SIDIS Prime are affected: SIDIS Prime vers:intdot/<4.0.800 (CVE-2024-29857, CVE-2024-30171, CVE-2024-30172,…
Read more of the source summary
CVE-2024-41996, CVE-2025-6965, CVE-2025-7783, CVE-2025-9230, CVE-2025-9232, CVE-2025-9670, CVE-2025-12816, CVE-2025-15284, CVE-2025-58751, CVE-2025-58752, CVE-2025-58754, CVE-2025-62522, CVE-2025-64718, CVE-2025-64756, CVE-2025-66030, CVE-2025-66031, CVE-2025-66035, CVE-2025-66412, CVE-2025-69277, CVE-2026-22610) CVSS Vendor Equipment Vulnerabilities v3 8.7 Siemens Siemens SIDIS Prime Out-of-bounds Read, Observable Discrepancy, Improper Input Validation, Improper Certificate Validation, Numeric Truncation Error, Use of Insufficiently Random Values, Out-of-bounds Write, Inefficient Regular Expression Complexity, Interpretation Conflict, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Relative Path Traversal, Allocation of Resources Without Limits…
Source published · CISA Cybersecurity Advisory

Inductive Automation Ignition Software

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute malicious code with OS application service account permissions that the authenticated, privileged application user did not intend on running. The following versions of Inductive Automation Ignition Software are affected: Ignition Software <8.3.0 (CVE-2025-13913) CVSS Vendor Equipment Vulnerabilities v3 6.3 Inductive…
Read more of the source summary
Automation Inductive Automation Ignition Software Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13913 A privileged Ignition user, intentionally or otherwise, imports an external file with a specially crafted payload, which executes embedded malicious code during deserialization. View CVE Details Affected Products Inductive Automation Ignition Software Vendor: Inductive Automation Product Version: Inductive Automation Ignition Software: <8.3.0 Product Status: known_affected Remediations Mitigation Fix - upgrade Ignition software from 8.1.x to 8.3.0 or greater. Mitigation MITIGATION (8.1.x Linux).…
Source published · CISA Cybersecurity Advisory

Siemens Heliox EV Chargers

View CSAF Summary Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Heliox EV Chargers are affected: Heliox Flex 180 kW EV Charging Station Heliox Mobile DC 40 kW…
Read more of the source summary
EV Charging Station CVSS Vendor Equipment Vulnerabilities v3 2.6 Siemens Siemens Heliox EV Chargers Improper Restriction of Communication Channel to Intended Endpoints Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-27769 Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable. View CVE Details Affected Products Siemens Heliox EV Chargers Vendor: Siemens Product Version: Heliox Flex 180 kW EV Charging Station, Heliox Mobile DC 40 kW EV Charging Station Product Status: known_affected Remediations Vendor fix Contact customer support for patch information via OTA update…
Source published · CISA Cybersecurity Advisory

Trane Tracer SC, Tracer SC+, and Tracer Concierge

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, execute arbitrary commands, or perform a denial-of-service on the product. The following versions of Trane Tracer SC, Tracer SC+, and Tracer Concierge are affected: Tracer SC Tracer SC+ Tracer Concierge CVSS Vendor Equipment Vulnerabilities v3 8.1 Trane Trane Tracer SC, Tracer SC+, and Tracer…
Read more of the source summary
Concierge Use of a Broken or Risky Cryptographic Algorithm, Memory Allocation with Excessive Size Value, Missing Authorization, Use of Hard-coded Credentials, Use of Hard-coded, Security-relevant Constants Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-28252 A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to bypass authentication and gain root-level access to the device. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC: <v4.4_SP7, Trane Tracer SC+: <v6.3.2310,…
Source published · CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products…
Read more of the source summary
where fixes are not, or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) vers:intdot/<4.1.2 (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) vers:all/* (CVE-2025-40943) SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) vers:intdot/<4.1.2…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing