Cybersecurity

CISA Advisories snapshot, Mar 31, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

IGL-Technologies eParking.fi

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of IGL-Technologies eParking.fi are affected: eParking.fi vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 IGL-Technologies IGL-Technologies eParking.fi…
Read more of the source summary
Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-29796 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to…
Source published · CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Automation Expert

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ Automation Expert product. The EcoStruxure™ Automation Expert product is plant automation software designed for digital control systems in discrete, hybrid and continuous industrial processes. A totally integrated automation solution designed to enhance your flexibility, efficiency and scalability. Failure to apply the remediation…
Read more of the source summary
provided below may risk execution of arbitrary commands on the engineering workstation, which could result in a potential compromise of full system. The following versions of Schneider Electric EcoStruxure Automation Expert are affected: EcoStruxure™ Automation Expert vers:intdot/<25.0.1, 25.0.1 CVSS Vendor Equipment Vulnerabilities v3 8.2 Schneider Electric Schneider Electric EcoStruxure Automation Expert Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-2273 CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric CNC Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products. The following versions of Mitsubishi Electric CNC Series are affected: M800VW (BND-2051W000) <=BB M800VS (BND-2052W000) <=BB M80V (BND-2053W000) <=BB M80VW (BND-2054W000) <=BB M800W (BND-2005W000) <=FM M800S (BND-2006W000)…
Read more of the source summary
<=FM M80 (BND-2007W000) <=FM M80W (BND-2008W000) <=FM E80 (BND-2009W000) <=FM C80 (BND-2036W000) vers:all/* M750VW (BND-1015W002) vers:all/* M730VW (BND-1015W000) vers:all/* M720VW (BND-1015W000) vers:all/* M750VS (BND-1012W002) vers:all/* M730VS (BND-1012W000-**) vers:all/* M720VS (BND-1012W000) vers:all/* M70V (BND-1018W000) vers:all/* E70 (BND-1022W000) vers:all/* NC Trainer2 (BND-1802W000) vers:all/* NC Trainer2 plus (BND-1803W000) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.9 Mitsubishi Electric Mitsubishi Electric CNC Series Improper Validation of Specified Index, Position, or Offset in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand…
Source published · CISA Cybersecurity Advisory

CTEK Chargeportal

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical…
Read more of the source summary
Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-25192 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized…
Source published · CISA Cybersecurity Advisory

CISA Urges Endpoint Management System Hardening After Cyberattack Against US Organization

CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.1 To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources…
Read more of the source summary
provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions. To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft’s newly released best practices for securing Microsoft Intune; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software: Use principles of least privilege when designing administrative roles. Leverage Microsoft Intune’s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations—permissions…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-66376 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read more of the source summary
Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20963 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read more of the source summary
Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Schneider Electric SCADAPack and RemoteConnect

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and…
Read more of the source summary
loss of confidentiality, integrity of the controller. The following versions of Schneider Electric SCADAPack and RemoteConnect are affected: SCADAPack™ vers:generic/ SCADAPack™ firmware vers:intdot/<9.12.2, 9.12.2, vers:intdot/<9.12.2, 9.12.2 () RemoteConnect vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric SCADAPack and RemoteConnect Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-0667 CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality &…
Source published · CISA Cybersecurity Advisory

CODESYS in Festo Automation Suite

View CSAF Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* FESTO…
Read more of the source summary
Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 FESTO, CODESYS CODESYS in Festo Automation Suite Direct Request ('Forced Browsing'), Untrusted Search Path, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Recursion, Improper Access Control, Use of Insufficiently Random Values, Improper Restriction of Communication Channel to Intended Endpoints, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Input During Web Page Generation ('Cross-site…
Source published · CISA Cybersecurity Advisory

Siemens SICAM SIAPP SDK

View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens…
Read more of the source summary
has released a new version for SICAM SIAPP SDK and recommends to update to the latest version. The following versions of Siemens SICAM SIAPP SDK are affected: SICAM SIAPP SDK vers:intdot/<2.1.7 CVSS Vendor Equipment Vulnerabilities v3 7.4 Siemens Siemens SICAM SIAPP SDK Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25569 An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing