Cybersecurity

CISA Advisories snapshot, Apr 6, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Automation Expert

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ Automation Expert product. The EcoStruxure™ Automation Expert product is plant automation software designed for digital control systems in discrete, hybrid and continuous industrial processes. A totally integrated automation solution designed to enhance your flexibility, efficiency and scalability. Failure to apply the remediation…
Read more of the source summary
provided below may risk execution of arbitrary commands on the engineering workstation, which could result in a potential compromise of full system. The following versions of Schneider Electric EcoStruxure Automation Expert are affected: EcoStruxure™ Automation Expert vers:intdot/<25.0.1, 25.0.1 CVSS Vendor Equipment Vulnerabilities v3 8.2 Schneider Electric Schneider Electric EcoStruxure Automation Expert Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-2273 CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric CNC Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products. The following versions of Mitsubishi Electric CNC Series are affected: M800VW (BND-2051W000) <=BB M800VS (BND-2052W000) <=BB M80V (BND-2053W000) <=BB M80VW (BND-2054W000) <=BB M800W (BND-2005W000) <=FM M800S (BND-2006W000)…
Read more of the source summary
<=FM M80 (BND-2007W000) <=FM M80W (BND-2008W000) <=FM E80 (BND-2009W000) <=FM C80 (BND-2036W000) vers:all/* M750VW (BND-1015W002) vers:all/* M730VW (BND-1015W000) vers:all/* M720VW (BND-1015W000) vers:all/* M750VS (BND-1012W002) vers:all/* M730VS (BND-1012W000-**) vers:all/* M720VS (BND-1012W000) vers:all/* M70V (BND-1018W000) vers:all/* E70 (BND-1022W000) vers:all/* NC Trainer2 (BND-1802W000) vers:all/* NC Trainer2 plus (BND-1803W000) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.9 Mitsubishi Electric Mitsubishi Electric CNC Series Improper Validation of Specified Index, Position, or Offset in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand…
Source published · CISA Cybersecurity Advisory

IGL-Technologies eParking.fi

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of IGL-Technologies eParking.fi are affected: eParking.fi vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 IGL-Technologies IGL-Technologies eParking.fi…
Read more of the source summary
Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-29796 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to…
Source published · CISA Cybersecurity Advisory

CTEK Chargeportal

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical…
Read more of the source summary
Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-25192 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized…
Source published · CISA Cybersecurity Advisory

Schneider Electric Modicon M241, M251, and M262

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product. The following versions of Schneider Electric Modicon M241, M251, and M262 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon M262 versions prior to 5.4.10.12…
Read more of the source summary
Modicon_Controller_M262 CVSS Vendor Equipment Vulnerabilities v3 5.3 Schneider Electric Schneider Electric Modicon M241, M251, and M262 Improper Resource Shutdown or Release Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13901 CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. View CVE Details Affected Products Schneider Electric Modicon M241, M251, and M262 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions…
Source published · CISA Cybersecurity Advisory

Schneider Electric EcoStruxure PME and EPO

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software offers that provides a…
Read more of the source summary
single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system. The following versions of Schneider Electric EcoStruxure PME and EPO are affected: EcoStruxure Power Monitoring Expert (PME) 2022 <=2022 EcoStruxure Power Monitoring Expert (PME) 2023 EcoStruxure Power Monitoring Expert (PME) 2023_R2 EcoStruxure Power Monitoring Expert (PME) 2024 EcoStruxure Power Monitoring Expert (PME) 2024_R2 EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module <=2022 EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20131 Cisco Secure Firewall Management Center (FMC) Software and Cisco Security Cloud Control (SCC) Firewall Management Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks…
Read more of the source summary
to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue…
Source published · CISA Cybersecurity Advisory

Automated Logic WebCTRL Premium Server

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read, intercept, or modify communications. The following versions of Automated Logic WebCTRL Premium Server are affected: WebCTRL Premium Server CVSS Vendor Equipment Vulnerabilities v3 9.1 Automated Logic Automated Logic WebCTRL Premium Server Multiple Binds to the Same Port, Authentication Bypass by Spoofing, Cleartext…
Read more of the source summary
Transmission of Sensitive Information Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-25086 Under certain conditions, an attacker could bind to the same port used by WebCTRL. This could allow the attacker to craft and send malicious packets and impersonate the WebCTRL service without requiring code injection into the WebCTRL software. View CVE Details Affected Products Automated Logic WebCTRL Premium Server Vendor: Automated Logic Product Version: Automated Logic WebCTRL Premium Server: <v8.5 Product Status: known_affected Remediations Mitigation Automated Logic notes that WebCTRL 7 is End of Life (EOL) and has been out of support since…
Source published · CISA Cybersecurity Advisory

Schneider Electric Modicon Controllers M241, M251, M258, and LMC058

View CSAF Summary Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser. The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions…
Read more of the source summary
prior to 5.4.13.12 Modicon_Controller_M251 Modicon Controllers M258 all firmware versions Modicon_Controllers_M258 Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058 CVSS Vendor Equipment Vulnerabilities v3 5.4 Schneider Electric Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated…
Source published · CISA Cybersecurity Advisory

CISA Urges Endpoint Management System Hardening After Cyberattack Against US Organization

CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.1 To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources…
Read more of the source summary
provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions. To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft’s newly released best practices for securing Microsoft Intune; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software: Use principles of least privilege when designing administrative roles. Leverage Microsoft Intune’s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations—permissions…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing