CISA Advisories records

Source published · CISA Cybersecurity Advisory

ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves publicly reported vulnerability. An attacker who successfully exploited these vulnerabilities could cause a crash, denial-of-service (DoS), or potentially remote code execution. The following versions of ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message…
Read more of the source summary
Syntax are affected: AC500 V3 PM5xxx 3.9.0, 3.9.0_HF1 CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax Out-of-bounds Write Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-15467 When parsing CMS (Auth)EnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before…
Source published · CISA Cybersecurity Advisory

Subnet Solutions PowerSYSTEM Center

View CSAF Summary Successful exploitation of these vulnerabilities could allow an authenticated attacker to expose sensitive information or cause a CRLF injection. The following versions of Subnet Solutions PowerSYSTEM Center are affected: PowerSYSTEM Center 2020 <=5.28.x (CVE-2026-35504) PowerSYSTEM Center 2020 >=5.8.x|<=5.28.x (CVE-2026-26289) PowerSYSTEM Center 2020 >=5.11.x|<=5.28.x (CVE-2026-33570) PowerSYSTEM…
Read more of the source summary
Center 2024 >=6.0.x|<=6.1.x (CVE-2026-26289, CVE-2026-35555, CVE-2026-35504) PowerSYSTEM Center 2026 7.0.x (CVE-2026-26289, CVE-2026-35555, CVE-2026-35504) CVSS Vendor Equipment Vulnerabilities v3 8.2 Subnet Solutions Inc. Subnet Solutions PowerSYSTEM Center Incorrect Authorization, Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-26289 PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only. View CVE Details Affected Products…
Source published · CISA Cybersecurity Advisory

Software Bill of Materials for AI - Minimum Elements

CISA and the Group of Seven (G7) international partners—Germany, Canada, France, Italy, Japan, the United Kingdom, and the European Union—have released joint guidance, Software Bill of Materials for AI – Minimum Elements, to help public and private sector stakeholders improve transparency in their artificial intelligence (AI) systems and supply chains. A software bill of materials (SBOM) acts as an “ingredients…
Read more of the source summary
list” for software that better positions organizations to understand their supply chains and make risk-informed decisions about how to protect their critical systems. The guidance builds on CISA’s previous work with federal and international partners to establish a shared vision for a software bill of materials and provides recommendations on minimum elements that should be included in an SBOM for AI. Because AI systems are software systems, these recommendations should be considered in addition to the general minimum elements for an SBOM. While not exhaustive or mandatory, the supplemental minimal elements outlined in this guidance reflect the consensus of G7 experts and will expand over time to keep pace with the rapid advancement of AI technology. Please share your…
Source published · CISA Cybersecurity Advisory

ABB WebPro SNMP Card PowerValue Multiple Vulnerabilities

View CSAF Summary ABB became aware of multiple internally discovered vulnerabilities in the WebPro SNMP card PowerValue for the product versions listed as affected in the advisory. Depending upon the vulnerability, an attacker with access to local network who successfully exploited this vulnerability could have - Unauthorized access - Insufficient Session Expiration leading to resource unavailability - Uncontrolled…
Read more of the source summary
Resource Consumption leading to DOS attack ABB strongly advises customers to update the latest firmware of affected products. The following versions of ABB WebPro SNMP Card PowerValue Multiple Vulnerabilities are affected: WebPro SNMP Card <=1.1.8.k, 1.1.8.p CVSS Vendor Equipment Vulnerabilities v3 8.8 ABB ABB WebPro SNMP Card PowerValue Multiple Vulnerabilities Improper Check for Unusual or Exceptional Conditions, Incorrect Implementation of Authentication Algorithm, Insufficient Session Expiration Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland…
Source published · CISA Cybersecurity Advisory

ABB AC500 V3 Multiple Vulnerabilities

View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS)…
Read more of the source summary
(CVE-2025-41691). The following versions of ABB AC500 V3 Multiple Vulnerabilities are affected: AC500 V3 <3.9.0, 3.9.0 CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AC500 V3 Multiple Vulnerabilities Direct Request ('Forced Browsing'), Incorrect Permission Assignment for Critical Resource, NULL Pointer Dereference Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-2595 The visualization allows users to create browser-based visualizations for monitoring and controlling industrial processes. Access to these visualizations can be restricted using the built-in user management. However, an unauthenticated…
Source published · CISA Cybersecurity Advisory

ABB Automation Builder Gateway for Windows

View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is disabled The following versions of ABB Automation Builder Gateway for Windows are affected:…
Read more of the source summary
Automation Builder <2.9.0, 2.9.0 CVSS Vendor Equipment Vulnerabilities v3 5.3 ABB ABB Automation Builder Gateway for Windows Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-41975 The gateway serves as a communication channel for various clients to AC500 PLCs. By default, the gateway listens on all available network adapters on port 1217 and can therefore be accessed remotely. How-ever, remote access to the gateway is only required in certain network configurations. Since the gateway is usually accessed locally, many users are unaware of this remote…
Source published · CISA Cybersecurity Advisory

Fuji Electric Tellus

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Fuji Electric Fuji Electric Tellus Exposed Dangerous Method or…
Read more of the source summary
Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8108 The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions. View CVE Details Affected Products Fuji Electric Tellus Vendor: Fuji Electric Product Version: Fuji Electric Tellus: 5.0.2 Product Status: known_affected Remediations Vendor fix Fuji Electric recommends that Tellus be installed only with administrator privileges. Relevant CWE: CWE-749 Exposed Dangerous Method or Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Kim Myung-gyu of Trend…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-42208 BerriAI LiteLLM SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known…
Read more of the source summary
Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-6973 Ivanti Endpoint Manager Mobile (EPMM) Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read more of the source summary
Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

MAXHUB Pivot Client Application

View CSAF Summary Successful exploitation of this vulnerability may enable an attacker to access tenant email addresses and associated information in cleartext or cause a denial-of-service condition. The following versions of MAXHUB Pivot client application are affected: MAXHUB Pivot client application CVSS Vendor Equipment Vulnerabilities v3 7.3 MAXHUB MAXHUB Pivot client application Use of a Broken or Risky…
Read more of the source summary
Cryptographic Algorithm Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-6411 This vulnerability, in the MAXHUB Pivot client application versions prior to v1.36.2, may allow an attacker to obtain encrypted tenant email addresses and related metadata from any tenant. Due to the presence of a hardcoded AES key within the application, the encrypted data can be decrypted, enabling access to tenant email addresses and associated information in cleartext. Furthermore, an attacker may be able to cause a denial-of-service condition by enrolling multiple unauthorized devices into a tenant via MQTT, potentially disrupting tenant operations. View CVE…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-0300 Palo Alto Networks PAN-OS Out-of-bounds Write Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read more of the source summary
Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Hitachi Energy PCM600

View CSAF Summary Hitachi Energy is aware of a vulnerability that affects the Hitachi Energy PCM600 product versions listed in this document. An attacker successfully exploiting this vulnerability can impact integrity of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy PCM600 are affected: PCM600 Legacy…
Read more of the source summary
vers:PCM600_Legacy/<=2.11 (CVE-2018-1002208) PCM600 3.0, 3.0_HF1, 3.0_HF2, 3.0_HF3, 3.1, 3.1_SP1, 3.1_SP2, 3.1_SP3 (CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208, CVE-2018-1002208) CVSS Vendor Equipment Vulnerabilities v3 4.4 Hitachi Energy Hitachi Energy PCM600 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2018-1002208 SharpZipLib before 1.0 RC1 is vulnerable to directory traversal, allowing attackers to write to arbitrary files via a ../ (dot dot slash) in a Zip archive entry that is mishandled during…
Source published · CISA Cybersecurity Advisory

Johnson Controls CEM AC2000

View CSAF Summary Successful exploitation of this vulnerability could allow a standard user to escalate privileges on the host machine. The following versions of Johnson Controls CEM AC2000 are affected: CEM AC2000 12.0 (CVE-2026-21661) CEM AC2000 11.0 (CVE-2026-21661) CEM AC2000 10.6 (CVE-2026-21661) CVSS Vendor Equipment Vulnerabilities v3 8.7 Johnson Controls Inc. Johnson Controls CEM AC2000 Uncontrolled Search…
Read more of the source summary
Path Element Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21661 The affected product is vulnerable to DLL hijacking, which could allow an attacker to escalate standard user privileges on the host machine. View CVE Details Affected Products Johnson Controls CEM AC2000 Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. CEM AC2000: 12.0, Johnson Controls Inc. CEM AC2000: 11.0, Johnson Controls Inc. CEM AC2000: 10.6 Product Status: known_affected Remediations Mitigation Johnson Controls recommends users apply the following mitigations:…
Source published · CISA Cybersecurity Advisory

ABB B&R PVI

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. An attacker who successfully exploited this vulnerability could read sensitive information in the logging data of the PVI client application. Logging is deactivated by default in all PVI client versions. The following versions of…
Read more of the source summary
ABB B&R PVI are affected: PVI <6.5.0, 6.5.0 (CVE-2026-0936) CVSS Vendor Equipment Vulnerabilities v3 5 ABB ABB B&R PVI Insertion of Sensitive Information into Log File Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-0936 An Insertion of Sensitive Information into Log File vulnerability in B&R PVI client versions prior to 6.5 may be abused by an authenticated local attacker to gather credential information which is processed by the PVI client application. The logging function of the PVI client application is disabled by default and must be explicitly enabled by the user. View CVE Details Affected Products ABB B&R PVI Vendor: ABB Product Version: ABB PVI…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Runtime

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. An attacker who successfully exploited this vulnerability could cause the product to stop. The following versions of ABB B&R Automation Runtime are affected: Automation Runtime <6.5, >=6.5, =R4.93 (CVE-2025-11044, CVE-2025-11044) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 6.8 ABB ABB B&R Automation Runtime Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-11044 An Allocation of Resources Without Limits or Throttling vulnerability in the ANSL-Server component of B&R Automation Runtime versions prior to 6.5 and prior to R4.93 could be exploited by an unauthenticated attacker on the net-work to win a race condition, resulting in permanent denial-of-service (DoS) conditions on affected devices. View CVE Details Affected Products ABB B&R Automation Runtime Vendor: ABB Product Version: ABB Automation Runtime <6.5, ABB Automation Runtime…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Studio

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. Successful exploitation of this vulnerability may enable an attacker to masquerade as a trusted party when B&R Automation Studio establishes a connection with a server via the ANSL over TLS or OPC-UA protocol. The following versions of ABB B&R…
Read more of the source summary
Automation Studio are affected: Automation Studio <6.5, 6.5 (CVE-2025-11043) CVSS Vendor Equipment Vulnerabilities v3 7.4 ABB ABB B&R Automation Studio Improper Certificate Validation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-11043 An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves to intercept and interfere with data exchanges. View CVE Details Affected Products ABB B&R Automation Studio Vendor: ABB Product Version: ABB Automation Studio <6.5 Product Status: fixed,…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-31431 Linux Kernel Incorrect Resource Transfer Between Spheres Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the…
Read more of the source summary
Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Careful Adoption of Agentic AI Services

CISA, in collaboration with the Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC) and other international and U.S. partners, released guidance for organizations on adopting agentic artificial intelligence (AI) systems. This guide outlines key security challenges and risks associated with agentic AI, and provides actionable steps for designing, deploying, and operating these systems…
Read more of the source summary
safely. It helps organizations align AI risk management with existing cybersecurity frameworks and strengthen oversight as agentic AI adoption grows. Please share your thoughts! We welcome your feedback. CISA Product Survey
Source published · CISA Cybersecurity Advisory

ABB Ability OPTIMAX

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to bypass user authentication on OPTIMAX installations that make use of the Azure Active Directory Single-Sign On integration. The following versions of ABB Ability OPTIMAX are affected: ABB Ability OPTIMAX 6.1 vers:all/* ABB Ability OPTIMAX 6.2 vers:all/* ABB Ability OPTIMAX 6.3 <6.3.1-251120 ABB Ability OPTIMAX 6.4…
Read more of the source summary
<6.4.1-251120 CVSS Vendor Equipment Vulnerabilities v3 8.1 ABB ABB Ability OPTIMAX Incorrect Implementation of Authentication Algorithm Background Critical Infrastructure Sectors: Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-14510 The vulnerability allows an attacker to bypass user authentication on OPTIMAX installations that make use of the Azure Active Directory Single-Sign On integration. View CVE Details Affected Products ABB Ability OPTIMAX Vendor: ABB Product Version: ABB ABB Ability OPTIMAX 6.1: vers:all/*, ABB ABB Ability OPTIMAX 6.2: vers:all/*, ABB ABB Ability OPTIMAX 6.3: <6.3.1-251120, ABB ABB Ability OPTIMAX 6.4: <6.4.1-251120 Product Status: known_affected Remediations…
Source published · CISA Cybersecurity Advisory

ABB AWIN Gateways

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely reboot the device or complete an unauthenticated query to reveal system configuration, including sensitive details. The following versions of ABB AWIN Gateways are affected: ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2 2.0-0 ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2 2.0-1 ABB AWIN…
Read more of the source summary
Firmware (1.2-0) installed on ABB AWIN GW120 1.2-0 ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120 1.2-1 CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AWIN Gateways Authentication Bypass by Capture-replay, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-13777 An unauthenticated query reveals data. Authentication Bypass due to Improper Session Validation. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing