View CSAF Summary SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following…
Read more of the source summary
versions of Siemens SIMATIC S7 PLC Web Server are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:intdot/<3.1.6 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:intdot/<3.1.6 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:intdot/<2.9.9 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787,…
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20182 Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Note: Please adhere to CISA’s guidelines to assess exposure and…
Read more of the source summary
mitigate risks associated with Cisco SD-WAN devices as outlined in Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems and Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems. Adhere to the applicable Binding Operational Directive (BOD) 22-01 guidance for cloud services or discontinue use of the product if mitigations are not available. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due…
View CSAF Summary The SIPROTEC 5 devices do not use sufficiently random numbers to generate session identifiers. This could facilitate a brute-force attack against a valid session identifier which could allow an unauthenticated remote attacker to hijack a valid user session. The affected session identifiers are only used in a subset of the endpoints that are provided by the affected products. Siemens is preparing…
Read more of the source summary
fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 are affected: SIPROTEC 5 6MD84 (CP300) vers:intdot/<11.0 (CVE-2024-54017) SIPROTEC 5 6MD85 (CP200) vers:all/* () SIPROTEC 5 6MD85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD86 (CP200) vers:all/* () SIPROTEC 5 6MD86 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD89 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MU85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7KE85 (CP200) vers:all/* () SIPROTEC 5 7KE85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP100) vers:intdot/>=7.80 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP150) vers:intdot/<11.0…
View CSAF Summary SIMATIC HMI Unified Comfort Panels before V21.0 are affected by a vulnerability that allows an unauthenticated attacker to access the web browser via the help link. This vulnerability allows an attacker to access the web browser through the Control Panel if it is not protected by the corresponding security mechanisms. This opens the possibility for the attacker to find backdoors, which might lead…
Read more of the source summary
to unwanted misconfigurations. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC are affected: SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort…
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves publicly reported vulnerability. An attacker who successfully exploited these vulnerabilities could cause a crash, denial-of-service (DoS), or potentially remote code execution. The following versions of ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message…
Read more of the source summary
Syntax are affected: AC500 V3 PM5xxx 3.9.0, 3.9.0_HF1 CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax Out-of-bounds Write Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-15467 When parsing CMS (Auth)EnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Fuji Electric Fuji Electric Tellus Exposed Dangerous Method or…
Read more of the source summary
Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8108 The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions. View CVE Details Affected Products Fuji Electric Tellus Vendor: Fuji Electric Product Version: Fuji Electric Tellus: 5.0.2 Product Status: known_affected Remediations Vendor fix Fuji Electric recommends that Tellus be installed only with administrator privileges. Relevant CWE: CWE-749 Exposed Dangerous Method or Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Kim Myung-gyu of Trend…
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS)…
Read more of the source summary
(CVE-2025-41691). The following versions of ABB AC500 V3 Multiple Vulnerabilities are affected: AC500 V3 <3.9.0, 3.9.0 CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AC500 V3 Multiple Vulnerabilities Direct Request ('Forced Browsing'), Incorrect Permission Assignment for Critical Resource, NULL Pointer Dereference Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-2595 The visualization allows users to create browser-based visualizations for monitoring and controlling industrial processes. Access to these visualizations can be restricted using the built-in user management. However, an unauthenticated…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an authenticated attacker to expose sensitive information or cause a CRLF injection. The following versions of Subnet Solutions PowerSYSTEM Center are affected: PowerSYSTEM Center 2020 <=5.28.x (CVE-2026-35504) PowerSYSTEM Center 2020 >=5.8.x|<=5.28.x (CVE-2026-26289) PowerSYSTEM Center 2020 >=5.11.x|<=5.28.x (CVE-2026-33570) PowerSYSTEM…
Read more of the source summary
Center 2024 >=6.0.x|<=6.1.x (CVE-2026-26289, CVE-2026-35555, CVE-2026-35504) PowerSYSTEM Center 2026 7.0.x (CVE-2026-26289, CVE-2026-35555, CVE-2026-35504) CVSS Vendor Equipment Vulnerabilities v3 8.2 Subnet Solutions Inc. Subnet Solutions PowerSYSTEM Center Incorrect Authorization, Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-26289 PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only. View CVE Details Affected Products…
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is disabled The following versions of ABB Automation Builder Gateway for Windows are affected:…
Read more of the source summary
Automation Builder <2.9.0, 2.9.0 CVSS Vendor Equipment Vulnerabilities v3 5.3 ABB ABB Automation Builder Gateway for Windows Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-41975 The gateway serves as a communication channel for various clients to AC500 PLCs. By default, the gateway listens on all available network adapters on port 1217 and can therefore be accessed remotely. How-ever, remote access to the gateway is only required in certain network configurations. Since the gateway is usually accessed locally, many users are unaware of this remote…
View CSAF Summary ABB became aware of multiple internally discovered vulnerabilities in the WebPro SNMP card PowerValue for the product versions listed as affected in the advisory. Depending upon the vulnerability, an attacker with access to local network who successfully exploited this vulnerability could have - Unauthorized access - Insufficient Session Expiration leading to resource unavailability - Uncontrolled…
Read more of the source summary
Resource Consumption leading to DOS attack ABB strongly advises customers to update the latest firmware of affected products. The following versions of ABB WebPro SNMP Card PowerValue Multiple Vulnerabilities are affected: WebPro SNMP Card <=1.1.8.k, 1.1.8.p CVSS Vendor Equipment Vulnerabilities v3 8.8 ABB ABB WebPro SNMP Card PowerValue Multiple Vulnerabilities Improper Check for Unusual or Exceptional Conditions, Incorrect Implementation of Authentication Algorithm, Insufficient Session Expiration Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland…