Cybersecurity

CISA Advisories snapshot, May 21, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Siemens SIMATIC S7 PLC Web Server

View CSAF Summary SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following…
Read more of the source summary
versions of Siemens SIMATIC S7 PLC Web Server are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:intdot/<3.1.6 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:intdot/<3.1.6 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:intdot/<2.9.9 (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787, CVE-2026-25789) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0) vers:all/* (CVE-2026-25786, CVE-2026-25787,…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20182 Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Note: Please adhere to CISA’s guidelines to assess exposure and…
Read more of the source summary
mitigate risks associated with Cisco SD-WAN devices as outlined in Emergency Directive 26-03: Mitigate Vulnerabilities in Cisco SD-WAN Systems and Supplemental Direction ED 26-03: Hunt and Hardening Guidance for Cisco SD-WAN Systems. Adhere to the applicable Binding Operational Directive (BOD) 22-01 guidance for cloud services or discontinue use of the product if mitigations are not available. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due…
Source published · CISA Cybersecurity Advisory

Siemens SIPROTEC 5

View CSAF Summary The SIPROTEC 5 devices do not use sufficiently random numbers to generate session identifiers. This could facilitate a brute-force attack against a valid session identifier which could allow an unauthenticated remote attacker to hijack a valid user session. The affected session identifiers are only used in a subset of the endpoints that are provided by the affected products. Siemens is preparing…
Read more of the source summary
fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 are affected: SIPROTEC 5 6MD84 (CP300) vers:intdot/<11.0 (CVE-2024-54017) SIPROTEC 5 6MD85 (CP200) vers:all/* () SIPROTEC 5 6MD85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD86 (CP200) vers:all/* () SIPROTEC 5 6MD86 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD89 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MU85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7KE85 (CP200) vers:all/* () SIPROTEC 5 7KE85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP100) vers:intdot/>=7.80 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP150) vers:intdot/<11.0…
Source published · CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC HMI Unified Comfort Panels before V21.0 are affected by a vulnerability that allows an unauthenticated attacker to access the web browser via the help link. This vulnerability allows an attacker to access the web browser through the Control Panel if it is not protected by the corresponding security mechanisms. This opens the possibility for the attacker to find backdoors, which might lead…
Read more of the source summary
to unwanted misconfigurations. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC are affected: SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort…
Source published · CISA Cybersecurity Advisory

Siemens Siemens ROS#

View CSAF Summary ROS# contains a ROS service file_server, that before version 2.2.2 contains a path traversal vulnerability which could allow an attacker to access, i.e. read and write, arbitrary files, which are accessible with the user rights of the user that runs the service, on the system that hosts service. Siemens has released a new version for ROS# and recommends to update to the latest version. The…
Read more of the source summary
following versions of Siemens Siemens ROS# are affected: ROS# vers:intdot/<2.2.2 CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens Siemens ROS# Relative Path Traversal Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-41551 Affected versions contain a path traversal vulnerability because user input is not properly sanitized. This could allow a remote attacker to access arbitrary files on the device. View CVE Details Affected Products Siemens Siemens ROS# Vendor: Siemens Product Version: ROS# Product Status: known_affected Remediations Mitigation For versions before 2.2.2: - run file_server on a trusted network only. - run file_server with…
Source published · CISA Cybersecurity Advisory

ABB Automation Builder Gateway for Windows

View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is disabled The following versions of ABB Automation Builder Gateway for Windows are affected:…
Read more of the source summary
Automation Builder <2.9.0, 2.9.0 CVSS Vendor Equipment Vulnerabilities v3 5.3 ABB ABB Automation Builder Gateway for Windows Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-41975 The gateway serves as a communication channel for various clients to AC500 PLCs. By default, the gateway listens on all available network adapters on port 1217 and can therefore be accessed remotely. How-ever, remote access to the gateway is only required in certain network configurations. Since the gateway is usually accessed locally, many users are unaware of this remote…
Source published · CISA Cybersecurity Advisory

ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves publicly reported vulnerability. An attacker who successfully exploited these vulnerabilities could cause a crash, denial-of-service (DoS), or potentially remote code execution. The following versions of ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message…
Read more of the source summary
Syntax are affected: AC500 V3 PM5xxx 3.9.0, 3.9.0_HF1 CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax Out-of-bounds Write Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-15467 When parsing CMS (Auth)EnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before…
Source published · CISA Cybersecurity Advisory

ABB AC500 V3 Multiple Vulnerabilities

View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS)…
Read more of the source summary
(CVE-2025-41691). The following versions of ABB AC500 V3 Multiple Vulnerabilities are affected: AC500 V3 <3.9.0, 3.9.0 CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AC500 V3 Multiple Vulnerabilities Direct Request ('Forced Browsing'), Incorrect Permission Assignment for Critical Resource, NULL Pointer Dereference Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-2595 The visualization allows users to create browser-based visualizations for monitoring and controlling industrial processes. Access to these visualizations can be restricted using the built-in user management. However, an unauthenticated…
Source published · CISA Cybersecurity Advisory

Fuji Electric Tellus

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Fuji Electric Fuji Electric Tellus Exposed Dangerous Method or…
Read more of the source summary
Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8108 The installation of Fuji Tellus adds a driver to the kernel which grants all users read and write permissions. View CVE Details Affected Products Fuji Electric Tellus Vendor: Fuji Electric Product Version: Fuji Electric Tellus: 5.0.2 Product Status: known_affected Remediations Vendor fix Fuji Electric recommends that Tellus be installed only with administrator privileges. Relevant CWE: CWE-749 Exposed Dangerous Method or Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Kim Myung-gyu of Trend…
Source published · CISA Cybersecurity Advisory

Software Bill of Materials for AI - Minimum Elements

CISA and the Group of Seven (G7) international partners—Germany, Canada, France, Italy, Japan, the United Kingdom, and the European Union—have released joint guidance, Software Bill of Materials for AI – Minimum Elements, to help public and private sector stakeholders improve transparency in their artificial intelligence (AI) systems and supply chains. A software bill of materials (SBOM) acts as an “ingredients…
Read more of the source summary
list” for software that better positions organizations to understand their supply chains and make risk-informed decisions about how to protect their critical systems. The guidance builds on CISA’s previous work with federal and international partners to establish a shared vision for a software bill of materials and provides recommendations on minimum elements that should be included in an SBOM for AI. Because AI systems are software systems, these recommendations should be considered in addition to the general minimum elements for an SBOM. While not exhaustive or mandatory, the supplemental minimal elements outlined in this guidance reflect the consensus of G7 experts and will expand over time to keep pace with the rapid advancement of AI technology. Please share your…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing