Cybersecurity

CISA Advisories snapshot, May 27, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records

Source published · CISA Cybersecurity Advisory

Eppendorf BioFlo 320

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full access to functionality and data with the bioreactor. The following versions of Eppendorf BioFlo 320 are affected: BioFlo 320 Bioreactor vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Eppendorf Eppendorf BioFlo 320 Use of Hard-coded Password Background Critical Infrastructure Sectors: Healthcare and Public…
Read more of the source summary
Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-7251 The affected product is vulnerable to due to VNC server using a hard-coded password. If a remote attacker knows the network address of any BioFlo 320 model with remote access enabled, they can gain full control of the user interface by using this password. Once connected, the attacker would have full access to all control panel features for the BioFlo 320. VNC traffic is not encrypted. View CVE Details Affected Products Eppendorf BioFlo 320 Vendor: Eppendorf Product Version: Eppendorf BioFlo 320 Bioreactor: vers:all/* Product Status: known_affected Remediations Mitigation Eppendorf has released a software update that permanently removes VNC access…
Source published · CISA Cybersecurity Advisory

ABB Ability Camera Connect

View CSAF Summary ABB is aware of public reports of vulnerabilities in a 3rd party component VLC media player Version 2.2.4 which was delivered together with the installation package of Camera Connect Version 1.5.0.14 and below. An update is available that resolves a privately reported outdated 3rd party component with vulnerabilities in the product versions listed as affected in this advisory. An attacker who…
Read more of the source summary
successfully exploited any of these vulnerabilities in the 3rd party component could potentially compromise the system in different ways. The following versions of ABB Ability Camera Connect are affected: Ability Camera Connect vers:intdot/<=1.5.0.14, 1.5.0.15 CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB Ability Camera Connect Heap-based Buffer Overflow, Integer Underflow (Wrap or Wraparound), Out-of-bounds Write, Uncontrolled Search Path Element, Integer Overflow or Wraparound, Off-by-one Error, Out-of-bounds Read, Double Free, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free Background Critical Infrastructure Sectors: Chemical, Commercial Facilities, Communications, Critical Manufacturing, Energy, Transportation Systems…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)

View CSAF Summary An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited this vulnerability could cause the product to stop. The following versions of ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM) are affected: Automation Runtime <6.3…
Read more of the source summary
Automation Runtime <Q4.93 CVSS Vendor Equipment Vulnerabilities v3 10 B&R ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM) Improper Resource Locking Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-3450 An Improper Resource Locking vulnerability in the SDM component of B&R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service conditions. View CVE Details Affected Products ABB B&R Automation Runtime DoS…
Source published · CISA Cybersecurity Advisory

ABB LVS MConfig

View CSAF Summary ABB became aware of an internally discovered vulnerability in the MConfig product versions listed as affected in the advisory. An attacker with access to local networks who successfully exploits vulnerability could have access to application’s sensitive information. ABB strongly advises customers to update MConfig with latest software version. The following versions of ABB LVS MConfig are affected:…
Read more of the source summary
LVS <=1.4.9.21 CVSS Vendor Equipment Vulnerabilities v3 7.4 ABB ABB LVS MConfig Cleartext Storage of Sensitive Information in Memory Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-9970 During the runtime of the MConfig Software application, an attacker can export the memory dump file into the operating system. If passwords are stored in plain text in memory, they will be included in these dump files. If such dump files are mishandled, attackers could obtain them and extract the passwords. View CVE Details Affected Products ABB LVS MConfig Vendor: ABB…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48172 LiteSpeed cPanel Plugin Privilege Escalation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read more of the source summary
Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

ABB AC500 V2

View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7745 Sending unsupported function codes to the AC500 V2 Modbus server might result in invalid responses. Fragments of previous responses might be added to the end of the response. View CVE Details Affected Products ABB AC500 V2 Vendor: ABB Product Version: ABB AC500 V2 <=2.5.2 Product Status: fixed, known_affected Remediations Vendor fix The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8…
Source published · CISA Cybersecurity Advisory

ABB Terra AC

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox…
Read more of the source summary
(UL40/80A) <=1.8.32, 1.8.33 Terra AC wallbox (UL32A) <=1.8.2, 1.8.34 Terra AC wallbox (MID/ CE) <=1.8.32, 1.8.34 Terra AC wallbox (JP) <=1.8.2, 1.8.34 CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Terra AC Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-5517 There is potential risk to pollute the memory when a specially crafted OCPP message may be sent to a target vulnerable charger by exploiting unencrypted communication to the Charging Station Management System (CSMS) or fully remotely from its CSMS server. View CVE Details Affected Products ABB…
Source published · CISA Cybersecurity Advisory

ABB AbilityTM Zenon Remote Transport Vulnerability

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this…
Read more of the source summary
vulnerability is not feasible unless the attacker has already gained access to the network where the affected ABB Ability™ zenon system is deployed. At the time of writing, there is no evidence that this vulnerability is being actively exploited in the wild. The following versions of ABB AbilityTM Zenon Remote Transport Vulnerability are affected: AbilityTM zenon >=7.50|<=14 CVSS Vendor Equipment Vulnerabilities v3 7.5 ABB ABB AbilityTM Zenon Remote Transport Vulnerability Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-9082 Drupal Core SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited…
Read more of the source summary
Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-34291 Langflow Origin Validation Error Vulnerability CVE-2026-34926 Trend Micro Apex One (On-Premise) Directory Traversal Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.…
Read more of the source summary
Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Runtime

View CSAF Summary An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could take over a remote session or execute code in the context of the user’s browser session. The following versions of ABB B&R Automation Runtime are affected: Automation Runtime…
Read more of the source summary
<6.4, 6.4 (CVE-2025-3449, CVE-2025-3448, CVE-2025-11498) CVSS Vendor Equipment Vulnerabilities v3 6.1 B&R ABB B&R Automation Runtime Generation of Predictable Numbers or Identifiers, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Formula Elements in a CSV File Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-3449 A Generation of Predictable Numbers or Identifiers vulnerability in the SDM component of B&R Automation Runtime versions before 6.4 may allow an unauthenticated network-based attacker to take over already established sessions. View CVE Details Affected Products ABB B&R…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Studio

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code…
Read more of the source summary
execution. The following versions of ABB B&R Automation Studio are affected: B&R Automation Studio <6.5, 6.5 (CVE-2025-6965, CVE-2025-3277, CVE-2023-7104, CVE-2022-35737, CVE-2020-15358, CVE-2020-13632, CVE-2020-13631, CVE-2020-13630, CVE-2020-13435, CVE-2020-13434, CVE-2020-11656, CVE-2020-11655, CVE-2019-19646, CVE-2019-19645, CVE-2019-8457, CVE-2018-20506, CVE-2018-20505, CVE-2018-20346, CVE-2018-8740, CVE-2017-10989, CVE-2016-6153, CVE-2015-6607, CVE-2015-5895, CVE-2015-3717, CVE-2015-3416) CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB B&R Automation Studio Numeric Truncation Error, Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, NULL Pointer Dereference, Incorrect User Management, Use…
Source published · CISA Cybersecurity Advisory

Hitachi Energy GMS600

View CSAF Summary Hitachi Energy is aware of the vulnerability, CVE-2022-4304 in the OSS component OpenSSL, that affects the GMS600 versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original…
Read more of the source summary
connection and thus be able to decrypt the application data sent over that connection. For immediate mitigation /workaround information, please refer to the General Mitigation Factors/Workarounds The following versions of Hitachi Energy GMS600 are affected: GMS600 vers:GMS600/>=1.3.0|<=1.3.1 (CVE-2022-4304) CVSS Vendor Equipment Vulnerabilities v3 5.9 Hitachi Energy Hitachi Energy GMS600 Observable Discrepancy Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2022-4304 A timing-based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style…
Source published · CISA Cybersecurity Advisory

ABB B&R PCs

View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. A network attacker could exploit the vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information. The following versions of ABB B&R PCs are affected: APC4100 <1.09,…
Read more of the source summary
1.09 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) APC910 <=1.25 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) C80 <1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) MPC3100 <1.24, 1.24 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237) PPC1200 <1.14, 1.14 (CVE-2023-45229, CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233, CVE-2023-45234, CVE-2023-45235,…
Source published · CISA Cybersecurity Advisory

ABB Terra AC Wallbox

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC Wallbox are affected: Terra AC…
Read more of the source summary
wallbox (JP) <=1.8.33, 1.8.36 (CVE-2025-10504, CVE-2025-12142, CVE-2025-12143) CVSS Vendor Equipment Vulnerabilities v3 6.1 ABB ABB Terra AC Wallbox Heap-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-10504 There is potential risk to pollute the memory when developing apps which has used to communicate with charger according to self-defined protocol if developers don’t strictly follow the field length which has not been validated in firmware. View CVE Details Affected Products ABB Terra AC Wallbox Vendor: ABB Product Version: ABB…
Source published · CISA Cybersecurity Advisory

CISA Adds Seven Known Exploited Vulnerabilities to Catalog

CISA has added seven new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2008-4250 Microsoft Windows Buffer Overflow Vulnerability CVE-2009-1537 Microsoft DirectX NULL Byte Overwrite Vulnerability CVE-2009-3459 Adobe Acrobat and Reader Heap-Based Buffer Overflow Vulnerability CVE-2010-0249 Microsoft Internet Explorer Use-After-Free Vulnerability…
Read more of the source summary
CVE-2010-0806 Microsoft Internet Explorer Use-After-Free Vulnerability CVE-2026-41091 Microsoft Defender Elevation of Privilege Vulnerability CVE-2026-45498 Microsoft Defender Denial of Service Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats.…
Source published · CISA Cybersecurity Advisory

Siemens RUGGEDCOM APE1808 Devices

View CSAF Summary A buffer overflow vulnerability in the User-ID™ Authentication Portal (aka Captive Portal) service of Palo Alto Networks PAN-OS software allows an unauthenticated attacker to execute arbitrary code with root privileges on the PA-Series and VM-Series firewalls by sending specially crafted packets. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or…
Read more of the source summary
not yet available. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/ The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-0300) CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens RUGGEDCOM APE1808 Devices Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-0300 A buffer overflow vulnerability in the User-ID™ Authentication Portal (aka Captive Portal) service of Palo Alto Networks PAN-OS software allows an unauthenticated attacker to…
Source published · CISA Cybersecurity Advisory

Kieback & Peter DDC Building Controllers

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of the victim's browser. The following versions of Kieback & Peter DDC Building Controllers are affected: DDC4002 <=1.12.14 (CVE-2026-4293) DDC4100 <=1.12.14 (CVE-2026-4293) DDC4200 <=1.12.14 (CVE-2026-4293) DDC4200-L <=1.12.14 (CVE-2026-4293) DDC4400 <=1.12.14 (CVE-2026-4293) DDC4002e <=1.23.4 (CVE-2026-4293)…
Read more of the source summary
DDC4200e <=1.23.4 (CVE-2026-4293) DDC4400e <=1.23.4 (CVE-2026-4293) DDC4020e <=1.23.4 (CVE-2026-4293) DDC4040e <=1.23.4 (CVE-2026-4293) DDC520 <=1.24.1 (CVE-2026-4293) CVSS Vendor Equipment Vulnerabilities v3 5.3 Kieback & Peter Kieback & Peter DDC Building Controllers Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Communications, Financial Services, Food and Agriculture, Government Services and Facilities, Healthcare and Public Health, Information Technology Countries/Areas Deployed: Austria, China, France, Germany, United Arab Emirates Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-4293 The affected products are vulnerable to cross-site…
Source published · CISA Cybersecurity Advisory

ZKTeco CCTV Cameras

View CSAF Summary Successful exploitation of this vulnerability could result in information disclosure, including capture of camera account credentials. The following versions of ZKTeco CCTV Cameras are affected: SSC335-GC2063-Face-0b77 Solution CVSS Vendor Equipment Vulnerabilities v3 9.1 ZKTeco ZKTeco CCTV Cameras Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructure Sectors:…
Read more of the source summary
Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-8598 An undocumented configuration export port is accessible on some models of ZKTeco CCTV cameras. This port does not require authentication and exposes critical information about the camera such as open services and camera account credentials. View CVE Details Affected Products ZKTeco CCTV Cameras Vendor: ZKTeco Product Version: ZKTeco SSC335-GC2063-Face-0b77 Solution: <V5.0.1.2.20260421 Product Status: known_affected Remediations Mitigation ZKTeco has patched this vulnerability in firmware version V5.0.1.2.20260421. ZKTeco recommends that users upgrade to firmware version V5.0.1.2.20260421 or later at their earliest opportunity.…
Source published · CISA Cybersecurity Advisory

ScadaBR

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to perform unauthenticated remote code execution. The following versions of ScadaBR are affected: ScadaBR 1.2.0 (CVE-2026-8602, CVE-2026-8603, CVE-2026-8604, CVE-2026-8605) CVSS Vendor Equipment Vulnerabilities v3 9.1 ScadaBR ScadaBR Missing Authentication for Critical Function, Improper Neutralization of Special Elements used…
Read more of the source summary
in an OS Command ('OS Command Injection'), Cross-Site Request Forgery (CSRF), Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Critical Manufacturing, Dams, Chemical, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Brazil Vulnerabilities Expand All + CVE-2026-8602 In ScadaBR version 1.2.0, a Missing Authentication for Critical Function vulnerability could allow an unauthenticated attacker to send a HTTP GET requests to the SCADA system and inject arbitrary sensor readings. View CVE Details Affected Products ScadaBR Vendor: ScadaBR Product Version: ScadaBR ScadaBR: 1.2.0 Product Status: known_affected Remediations Vendor fix ScadaBR has not responded to requests to work with CISA to mitigate this…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing