Cybersecurity

CISA Advisories snapshot, May 27, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

ABB CoreSense HM and CoreSense M10

View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in this advisory. A path traversal vulnerability in these products can allow unauthenticated users to gain access to restricted directories. Exploiting this vulnerability can lead to complete system compromise and exposure of sensitive information. The following versions of ABB CoreSense HM and CoreSense…
Read more of the source summary
M10 are affected: CoreSense™ HM <=2.3.1, 2.3.4 (CVE-2025-3465) CoreSense™ M10 <=1.4.1.12, 1.4.1.31 (CVE-2025-3465) CVSS Vendor Equipment Vulnerabilities v3 7.1 ABB ABB CoreSense HM and CoreSense M10 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Food and Agriculture, Commercial Facilities, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-3465 A path traversal vulnerability in these products can allow unauthenticated users to gain access to restricted directories. Exploiting this vulnerability can lead to complete system compromise and exposure of sensitive information. View CVE Details Affected Products ABB…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-42897 Microsoft Exchange Server Cross-Site Scripting Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk…
Read more of the source summary
of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

Siemens Ruggedcom Rox

View CSAF Summary Ruggedcom Rox contains an input validation vulnerability in the feature key installation process that could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are…
Read more of the source summary
affected: RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 RUGGEDCOM ROX MX5000RE vers:intdot/<2.17.1 RUGGEDCOM ROX RX1400 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1500 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1501 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1510 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1511 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1512 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1524 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1536 vers:intdot/<2.17.1 RUGGEDCOM ROX RX5000 vers:intdot/<2.17.1 CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens Ruggedcom Rox Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities…
Source published · CISA Cybersecurity Advisory

Siemens Solid Edge

View CSAF Summary Solid Edge SE2026 before Update 5 is affected by two file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Solid Edge SE2026 and recommends to update to the latest version. The following versions of Siemens Solid…
Read more of the source summary
Edge are affected: Solid Edge vers:intdot/<226.0.5 CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Access of Uninitialized Pointer, Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-44411 The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. View CVE Details Affected Products Siemens Solid Edge Vendor: Siemens Product Version: Solid Edge Product Status: known_affected Remediations Vendor fix Update to V226.0 Update 5 or later version…
Source published · CISA Cybersecurity Advisory

Siemens SENTRON 7KT PAC1261 Data Manager

View CSAF Summary The web server in SENTRON 7KT PAC1261 Data Manager Before V2.1.0 contains a request smuggling vulnerability in the Go Project's net/http package that could allow an attacker to retrieve authorization tokens that can be used to gain administrative control over the device. Siemens has released a new version for SENTRON 7KT PAC1261 Data Manager and recommends to update to the latest version. The…
Read more of the source summary
following versions of Siemens SENTRON 7KT PAC1261 Data Manager are affected: SENTRON 7KT PAC1261 Data Manager vers:intdot/<2.1.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens SENTRON 7KT PAC1261 Data Manager Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-22871 The net/http package improperly accepts a bare LF as a line terminator in chunked data chunk-size lines. This can permit request smuggling if a net/http server is used in conjunction with a server that incorrectly accepts a bare LF as part of a chunk-ext. View CVE Details Affected Products Siemens SENTRON 7KT…
Source published · CISA Cybersecurity Advisory

Siemens Simcenter Femap

View CSAF Summary Simcenter Femap is affected by heap based buffer overflow vulnerability in Datakit library that could be triggered when the application reads files in IPT format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for…
Read more of the source summary
Simcenter Femap and recommends to update to the latest version. The following versions of Siemens Simcenter Femap are affected: Simcenter Femap vers:intdot/<2512.0003 CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Simcenter Femap Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-12659 The affected applications contains a memory corruption vulnerability while parsing specially crafted IPT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27349, ZDI-CAN-27389) View CVE Details Affected Products Siemens Simcenter Femap Vendor: Siemens Product Version: Simcenter…
Source published · CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC HMI Unified Comfort Panels before V21.0 are affected by a vulnerability that allows an unauthenticated attacker to access the web browser via the help link. This vulnerability allows an attacker to access the web browser through the Control Panel if it is not protected by the corresponding security mechanisms. This opens the possibility for the attacker to find backdoors, which might lead…
Read more of the source summary
to unwanted misconfigurations. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC are affected: SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) vers:intdot/<21 (CVE-2026-27662) SIMATIC HMI MTP1200 Comfort…
Source published · CISA Cybersecurity Advisory

Siemens SIPROTEC 5

View CSAF Summary The SIPROTEC 5 devices do not use sufficiently random numbers to generate session identifiers. This could facilitate a brute-force attack against a valid session identifier which could allow an unauthenticated remote attacker to hijack a valid user session. The affected session identifiers are only used in a subset of the endpoints that are provided by the affected products. Siemens is preparing…
Read more of the source summary
fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 are affected: SIPROTEC 5 6MD84 (CP300) vers:intdot/<11.0 (CVE-2024-54017) SIPROTEC 5 6MD85 (CP200) vers:all/* () SIPROTEC 5 6MD85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD86 (CP200) vers:all/* () SIPROTEC 5 6MD86 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MD89 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 6MU85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7KE85 (CP200) vers:all/* () SIPROTEC 5 7KE85 (CP300) vers:intdot/>=7.80|<11.0 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP100) vers:intdot/>=7.80 (CVE-2024-54017) SIPROTEC 5 7SA82 (CP150) vers:intdot/<11.0…
Source published · CISA Cybersecurity Advisory

Siemens Ruggedcom Rox

View CSAF Summary Ruggedcom Rox contains an input validation vulnerability in the Scheduler functionality that could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are affected:…
Read more of the source summary
RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 RUGGEDCOM ROX MX5000RE vers:intdot/<2.17.1 RUGGEDCOM ROX RX1400 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1500 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1501 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1510 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1511 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1512 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1524 vers:intdot/<2.17.1 RUGGEDCOM ROX RX1536 vers:intdot/<2.17.1 RUGGEDCOM ROX RX5000 vers:intdot/<2.17.1 CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens Ruggedcom Rox Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand…
Source published · CISA Cybersecurity Advisory

Siemens SIMATIC

View CSAF Summary SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version. The following versions of Siemens SIMATIC are affected: SIMATIC CN 4100 vers:intdot/<5.0 CVSS Vendor Equipment Vulnerabilities v3 9.6 Siemens Siemens…
Read more of the source summary
SIMATIC NULL Pointer Dereference, Reachable Assertion, Use After Free, Out-of-bounds Write, Integer Overflow or Wraparound, Allocation of Resources Without Limits or Throttling, Out-of-bounds Read, Covert Timing Channel, Stack-based Buffer Overflow, Inefficient Algorithmic Complexity, Missing Release of Memory after Effective Lifetime, Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Input Validation, Improper Locking, Uncontrolled Recursion, Buffer Access with Incorrect Length Value, Race Condition within a Thread, Missing Synchronization, Use of Uninitialized Resource, Double Free, Missing Release of Resource after Effective Lifetime, Loop with Unreachable Exit Condition ('Infinite Loop'), Improper Update of Reference Count, Improper…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.