Cybersecurity

CISA Advisories snapshot, Jun 8, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Fourth Frontier Frontier X Mobile Application, Frontier X2

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm. The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected: Frontier X Android application vers<v15.0.0 Frontier X IOS application vers<v25.0.0…
Read more of the source summary
Frontier X2 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 8.8 Fourth Frontier Fourth Frontier Frontier X Mobile Application, Frontier X2 Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-5768 The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to…
Source published · CISA Cybersecurity Advisory

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-8398 Daemon Tools Lite Embedded Malicious Code Vulnerability CVE-2026-45321 TanStack Unspecified Vulnerability CVE-2026-48027 Nx Console Embedded Malicious Code Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose…
Read more of the source summary
significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA…
Source published · CISA Cybersecurity Advisory

ABB Ability Camera Connect

View CSAF Summary ABB is aware of public reports of vulnerabilities in a 3rd party component VLC media player Version 2.2.4 which was delivered together with the installation package of Camera Connect Version 1.5.0.14 and below. An update is available that resolves a privately reported outdated 3rd party component with vulnerabilities in the product versions listed as affected in this advisory. An attacker who…
Read more of the source summary
successfully exploited any of these vulnerabilities in the 3rd party component could potentially compromise the system in different ways. The following versions of ABB Ability Camera Connect are affected: Ability Camera Connect vers:intdot/<=1.5.0.14, 1.5.0.15 CVSS Vendor Equipment Vulnerabilities v3 9.8 ABB ABB Ability Camera Connect Heap-based Buffer Overflow, Integer Underflow (Wrap or Wraparound), Out-of-bounds Write, Uncontrolled Search Path Element, Integer Overflow or Wraparound, Off-by-one Error, Out-of-bounds Read, Double Free, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free Background Critical Infrastructure Sectors: Chemical, Commercial Facilities, Communications, Critical Manufacturing, Energy, Transportation Systems…
Source published · CISA Cybersecurity Advisory

ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)

View CSAF Summary An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited this vulnerability could cause the product to stop. The following versions of ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM) are affected: Automation Runtime <6.3…
Read more of the source summary
Automation Runtime <Q4.93 CVSS Vendor Equipment Vulnerabilities v3 10 B&R ABB B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM) Improper Resource Locking Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-3450 An Improper Resource Locking vulnerability in the SDM component of B&R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service conditions. View CVE Details Affected Products ABB B&R Automation Runtime DoS…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48172 LiteSpeed cPanel Plugin Privilege Escalation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of…
Read more of the source summary
Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Source published · CISA Cybersecurity Advisory

ABB LVS MConfig

View CSAF Summary ABB became aware of an internally discovered vulnerability in the MConfig product versions listed as affected in the advisory. An attacker with access to local networks who successfully exploits vulnerability could have access to application’s sensitive information. ABB strongly advises customers to update MConfig with latest software version. The following versions of ABB LVS MConfig are affected:…
Read more of the source summary
LVS <=1.4.9.21 CVSS Vendor Equipment Vulnerabilities v3 7.4 ABB ABB LVS MConfig Cleartext Storage of Sensitive Information in Memory Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-9970 During the runtime of the MConfig Software application, an attacker can export the memory dump file into the operating system. If passwords are stored in plain text in memory, they will be included in these dump files. If such dump files are mishandled, attackers could obtain them and extract the passwords. View CVE Details Affected Products ABB LVS MConfig Vendor: ABB…
Source published · CISA Cybersecurity Advisory

ABB AC500 V2

View CSAF Summary ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC The following versions of ABB AC500 V2 are affected: AC500 V2 <=2.5.2, 2.5.3 CVSS Vendor Equipment Vulnerabilities v3 5.8 ABB ABB AC500 V2 Buffer Over-read Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7745 Sending unsupported function codes to the AC500 V2 Modbus server might result in invalid responses. Fragments of previous responses might be added to the end of the response. View CVE Details Affected Products ABB AC500 V2 Vendor: ABB Product Version: ABB AC500 V2 <=2.5.2 Product Status: fixed, known_affected Remediations Vendor fix The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.8…
Source published · CISA Cybersecurity Advisory

ABB Terra AC

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior. The following versions of ABB Terra AC are affected: Terra AC wallbox…
Read more of the source summary
(UL40/80A) <=1.8.32, 1.8.33 Terra AC wallbox (UL32A) <=1.8.2, 1.8.34 Terra AC wallbox (MID/ CE) <=1.8.32, 1.8.34 Terra AC wallbox (JP) <=1.8.2, 1.8.34 CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Terra AC Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-5517 There is potential risk to pollute the memory when a specially crafted OCPP message may be sent to a target vulnerable charger by exploiting unencrypted communication to the Charging Station Management System (CSMS) or fully remotely from its CSMS server. View CVE Details Affected Products ABB…
Source published · CISA Cybersecurity Advisory

ABB Ability Zenon Remote Transport Vulnerability (Update A)

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this…
Read more of the source summary
vulnerability is not feasible unless the attacker has already gained access to the network where the affected ABB Ability Zenon system is deployed. At the time of writing, there is no evidence that this vulnerability is being actively exploited in the wild. The following versions of ABB Ability Zenon Remote Transport Vulnerability are affected: Ability Zenon >=7.50|<=14 CVSS Vendor Equipment Vulnerabilities v3 7.5 ABB ABB Ability Zenon Remote Transport Vulnerability Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Chemical, Communications, Critical Manufacturing, Dams, Energy, Healthcare and Public Health, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland…
Source published · CISA Cybersecurity Advisory

Eppendorf BioFlo 320

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain full access to functionality and data with the bioreactor. The following versions of Eppendorf BioFlo 320 are affected: BioFlo 320 Bioreactor vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 Eppendorf Eppendorf BioFlo 320 Use of Hard-coded Password Background Critical Infrastructure Sectors: Healthcare and Public…
Read more of the source summary
Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-7251 The affected product is vulnerable to due to VNC server using a hard-coded password. If a remote attacker knows the network address of any BioFlo 320 model with remote access enabled, they can gain full control of the user interface by using this password. Once connected, the attacker would have full access to all control panel features for the BioFlo 320. VNC traffic is not encrypted. View CVE Details Affected Products Eppendorf BioFlo 320 Vendor: Eppendorf Product Version: Eppendorf BioFlo 320 Bioreactor: vers:all/* Product Status: known_affected Remediations Mitigation Eppendorf has released a software update that permanently removes VNC access…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing